Bosch Security Systems DCNM-IDESKX DCNM-IDESK, DCNM-IDESKVID User Manual DCN HW en part 1

Bosch Security Systems BV DCNM-IDESK, DCNM-IDESKVID DCN HW en part 1

Contents

DCN_HW_en part 1

Download: Bosch Security Systems DCNM-IDESKX DCNM-IDESK, DCNM-IDESKVID User Manual DCN HW en part 1
Mirror Download [FCC.gov]Bosch Security Systems DCNM-IDESKX DCNM-IDESK, DCNM-IDESKVID User Manual DCN HW en part 1
Document ID4032348
Application IDxkkNjDHyJ9P6UfH9nCgAoA==
Document DescriptionDCN_HW_en part 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize371.67kB (4645866 bits)
Date Submitted2018-10-11 00:00:00
Date Available2018-10-12 00:00:00
Creation Date2018-10-11 13:49:54
Producing SoftwareiText 2.1.7 by 1T3XT
Document Lastmod2018-10-11 13:49:54
Document TitleDCN_HW_en part 1
Document Creatorpdfsam-console (Ver. 2.4.1e)

DICENTIS
Conference System
en
Hardware Installation Manual
DICENTIS
Table of contents | en
Table of contents
Safety
About this manual
2.1
Intended audience
2.2
Alerts and notice signs
2.3
Copyright and disclaimer
2.4
Document history
System installation overview
3.1
Typical system setup
10
3.2
System extension
13
System installation design and planning
17
4.1
System capabilities
17
4.2
Hardware requirements
19
4.3
Power supply capacity calculation plan
22
4.3.1
Calculation using DCNM-APS(2) or DCNM-PS(2)
22
4.3.2
Calculation using PoE switches
24
4.4
Redundancy options
26
4.4.1
Redundant cabling for DCNM‑APS/DCNM‑PS units
27
4.4.2
Redundant cabling for DCNM-APS2/DCNM-PS2 units
28
4.4.3
Redundant server PC
30
Installation material and tools
31
5.1
DICENTIS System Cable Assemblies
31
5.2
DCNM-CBCON Connectors for DICENTIS cable
32
5.3
DCNM-CBTK System Network Cable Toolkit
33
5.4
DCNM-CB250-I System Installation Cable
34
5.5
DCNM-CBCPLR Cable couplers
35
5.5.1
Using a cable coupler to extend a cable
35
5.5.2
Using a cable coupler as a break-out box
35
5.5.3
Using a cable coupler as an interface between different types of cable
36
5.5.4
Using a cable coupler to insert power locally
38
Mechanical installation of Central Equipment
40
6.1
Audio processor and powering switch and Powering switch
40
Mechanical installation of Contribution Devices
43
7.1
DICENTIS devices
43
7.2
DCNMM-IDESK / DCNM-IDESKVID Interpreter desk
46
7.3
DICENTIS Microphones
49
7.4
DCNM-MMDSP Anti-reflection foil
51
7.5
DCNM-NCH Name Card Holder
51
7.6
DCNM-IDESKINT On-air & telephone interface DCNM-IDESK
52
Installation Test
53
Bosch Security Systems B.V.
Hardware Installation Manual
2018.09 | V1.8 |
4
en | Safety
DICENTIS
Safety
Prior to installing or operating products, always read the Important Safety Instructions which
are available as a separate multilingual document: Important Safety Instructions (Safety_ML).
These instructions are supplied together with all equipment that can be connected to the
mains supply.
Safety precautions
Some of the DICENTIS Conference System products are designed to be connected to the
public mains network.
To avoid any risk of electric shock, all interventions must be carried out with disconnected
mains supply.
Interventions with the equipment switched on are authorized only when it is impossible to
switch the equipment off. The operation must only be performed by qualified personnel.
Old electrical and electronic appliances
Electrical or electronic devices that are no longer serviceable must be collected separately and
sent for environmentally compatible recycling (in accordance with the European Waste
Electrical and Electronic Equipment Directive).
To dispose of old electrical or electronic devices, you should use the return and collection
systems put in place in the country concerned.
Class A equipment (commercial broadcasting equipment)
This equipment is for professional (Class A) electromagnetic compatibility equipment. Seller
or user should pay attention to this point. It is intended for use outside the home.
Warning!
Changes or modifications not expressly approved by Bosch Security Systems could void the
user’s authority to operate the equipment.
FCC Statements - Class A digital device
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be required to correct the
interference at his/her own expense.
IC Statement
This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
2018.09 | V1.8 |
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
Safety | en
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
Bosch Security Systems B.V.
Hardware Installation Manual
2018.09 | V1.8 |
6
en | About this manual
DICENTIS
About this manual
The purpose of this manual is to provide information required for installing the DICENTIS
Conference System.
This installation manual is available as a digital document in the Adobe portable document
format (PDF).
For more information, refer to the product related information on www.boschsecurity.com
2.1
Intended audience
This hardware installation manual is intended for installers of a DICENTIS Conference System.
2.2
Alerts and notice signs
Four types of signs can be used in this manual. The type is closely related to the effect that
may be caused if it is not observed. These signs - from least severe effect to most severe
effect - are:
Notice!
Containing additional information. Usually, not observing a ‘notice’ does not result in damage
to the equipment or personal injuries.
Caution!
The equipment or the property can be damaged, or persons can be lightly injured if the alert
is not observed.
Warning!
The equipment or the property can be seriously damaged, or persons can be severely injured
if the alert is not observed.
Danger!
Not observing the alert can lead to severe injuries or death.
2.3
Copyright and disclaimer
All rights reserved. No part of this document may be reproduced or transmitted in any form by
any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior
written permission of the publisher. For information on getting permission for reprints and
excerpts, contact Bosch Security Systems B.V..
The content and illustrations are subject to change without prior notice.
2.4
Document history
Release date
Documentation version
Reason
2013.08
V1.0
1st edition.
2014.07
V1.1
2nd edition.
New sections: 1 WEEE, 3.2
system ext, 5.2.1, 5.2.2.
2018.09 | V1.8 |
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
About this manual | en
Release date
Documentation version
Reason
Sections updated: 2.4, 4.3.2,
5.2, 5.3, 5.4, 7.2 +
DCNM‑MICx added.
2014.10
V1.2
3rd edition.
Sections updated: 2.4, 3.2,
4.1 and 4.3.1.
2015.07
V1.3
4th edition.
New section: 4.4, including
sub-sections: 4.4.1, 4.4.2, and
4.4.3.
Sections updated: 2.4, 3.1,
3.2, 4.1, 4.3, 4.3.1, 5.3, 5.4,
6.1, 7.4, 8.
2015.11
V1.31
5th edition.
Sections updated: 2.4, 7.1.
Terminology updated.
2016.07
V1.4
6th edition.
Terminology updated.
DCN multimedia changed to
DICENTIS .
Sections updated: 3.1, 3.2,
4.1, 4.3.1, 4.3.2, 4.4.1, 4.4.2,
4.4.3, 5.3, 5.4, 7.1, 7.2, 7.3,
7.4, 8.
2017.10
V1.5
7th edition.
Terminology and product
names updated.
New section: 5.5
Sections updated: 5.2.1,
5.2.2, 7.1 new radio
interference warning added.
2017.12
V1.6
8th edition.
Sections updated: 5.5.3,
5.5.4.
2018.04
V1.7
9th edition.
Sections updated: 3.1, 3.2,
4.3.1, 4.3.2, 4.4, 5.2, 5.4,
5.5.4.
New section: 7.2 DCNMIDESK and DCNM-IDESKVID
Interpreter desk added.
2018.09
V1.8
10th edition.
Sections updated: 1, 7.2.
Bosch Security Systems B.V.
Hardware Installation Manual
2018.09 | V1.8 |
8
en | About this manual
Release date
DICENTIS
Documentation version
Reason
New section: 7.2 DCNMIDESKINT On-air & telephone
interface DCNM-IDESK
2018.09 | V1.8 |
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
System installation overview | en
System installation overview
It is advisable to participate in the DICENTIS Conference System training before you install,
configure, prepare, and operate a DICENTIS Conference System.
The DICENTIS Conference System is an IP based conference system which runs on an OMNEO
compatible Ethernet network. It is used for distributing and processing audio, video and data
signals.
The DICENTIS Conference System can be quickly and easily configured as a daisy‑chain
configuration or as a star configuration:
–
Daisy‑chain configuration: Uses dedicated cabling, consisting of CAT‑5e cables including
two additional power conductors (see Typical system setup, page 10).
–
Star configuration: Each DICENTIS device is connected with an individual standard
CAT‑5e cable. An Ethernet switch is also required for providing Power over Ethernet
(PoE).
Notice!
When Power over Ethernet is used, DICENTIS devices cannot be daisy‑chained. Please use
unshielded cable for the DICENTIS discussion devices.
See also
–
Bosch Security Systems B.V.
Typical system setup, page 10
Hardware Installation Manual
2018.09 | V1.8 |
10
en | System installation overview
3.1
DICENTIS
Typical system setup
5.1
5.2
Figure 3.1: Typical DICENTIS Conference System setup
A typical DICENTIS Conference System consists of:
1.
System server controller (PC):
–
2.
–
3.
The heart of the system. It licenses functionality, configures and controls the system.
Client PC:
Can be used to: Manage meetings, prepare meetings and configure the system.
Audio processor and powering switch (DCNM-APS / DCNM-APS2):
–
Controls the system audio, routes audio from and to the system and supplies power
to the DICENTIS devices.
4.
Powering switch (DCNM-PS / DCNM-PS2):
–
5.
Is used to increase the number of DICENTIS devices connected to the system.
DICENTIS devices: DCNM-D, DCNM-DVT, DCNM-DSL, DCNM-DE / DCNM-MMD2, DCNMMMD:
–
Participants can use their DICENTIS device to contribute to a meeting.
–
5.1 is a DICENTIS Multimedia device used for “system power on/off”. This device is
always connected to the powered socket of the Audio processor and powering
switch or Powering switch.
Note: Only one DICENTIS Multimedia device should be connected here.
–
5.2 is a DICENTIS device used via a “Power over Ethernet” (PoE) Ethernet switch.
Note: Only one DICENTIS device should be connected here.
–
5.3 are DICENTIS Interpretation desks: DCNM-IDESK and DCNM-IDESKVID. Provides
extensive facilities for professional interpretation for the DICENTIS Conference
System.
Note: A maximum of 10 desks can be installed per booth.
6.
System Network Cable (DCNM‑CBxxx):
–
Connects DICENTIS devices, the Audio processor and powering switch, and one or
more Powering switches to each other.
7.
Ethernet switch:
–
Ethernet switch with PoE on some ports.
- Routes the system data via Ethernet.
- Provides power to the DICENTIS devices via PoE.
2018.09 | V1.8 |
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
System installation overview | en
8.
CAT‑5e Ethernet cable (minimum requirement).
9.
Optional video camera (Onvif Profile-S compatible cameras, Sony IP cameras via CGI
11
commands, or Panasonic HD Integrated IP) + external power supply:
–
Captures the image of a speaking participant.
Note: The Sony camera needs to be placed in a separate VLAN to avoid problems with the
multicast data.
Note: The Panasonic camera requires an external H.264 encoder if the SDI video needs to
be displayed on the multimedia devices (or in the Meeting Application).
Figure 3.2: Typical camera setup
A typical camera setup in a DICENTIS Conference System consists of:
1. H.264 encoder to encode the HD SDI video to H.264
2. HD-SDI switcher
3. Projector
4. Video camera (Onvif Profile-S compatible camera, Sony, Panasonic)
5. System server controller (PC)
6. L3 Ethernet switch
7. Audio processor and powering switch (DCNM-APS / DCNM-APS2)
8. DCNM-MMD2
Cables:
–
Dotted line = HD-SDI (coax cable)
–
Black with arrow = Ethernet TCP/IP
–
Black straight line = DCNM-cable
Bosch Security Systems B.V.
Hardware Installation Manual
2018.09 | V1.8 |
12
en | System installation overview
DICENTIS
This system overview does not give information on redundant network options. For more
information, refer to Redundancy options, page 26.
2018.09 | V1.8 |
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
3.2
System installation overview | en
13
System extension
The DICENTIS Conference System is scalable from small to medium to large. This section
describes what a small, medium and large system is and what the requirements are for these
systems:
A small DICENTIS Conference System (see Typical system setup, page 10) consists of:
–
up to 100 DICENTIS devices.
–
all DICENTIS devices in 1 subnet.
–
1 DICENTIS Audio processor and powering switch for the audio processing.
–
1 Server PC which hosts the DICENTIS services.
A medium DICENTIS Conference System consists of:
–
up to 450 DICENTIS nodes.
Refer to table X about the node count of DICENTIS equipment.
–
all DICENTIS devices in 1 subnet.
–
1 DICENTIS Audio processor and powering switch for the audio processing.
–
1 Server PC which hosts the DICENTIS services.
–
1 ARNI-Standard to increase the size of the system.
A large DICENTIS Conference System consists of:
–
up to 750 DICENTIS devices.
–
multiple subnets connected by use of a router/L3 switch.
–
Each subnet can have up to 450 DICENTIS nodes.
Refer to the following table for the node count of DICENTIS equipment.
–
The first subnet has:
- 1 DICENTIS Audio processor and powering switch for the audio processing.
- 1 Server PC which hosts the DICENTIS services.
- 1 ARNI-Enterprise to increase the size of the system.
–
All other subnets have 1 ARNI-Standard to increase the size of the system.
Note: There is no DICENTIS Audio processor and powering switch in the other
subnets.
Device
Node count
DICENTIS server
DICENTIS meeting application
DICENTIS Audio processor and powering switch
DICENTIS Powering switch
DICENTIS multimedia device
DICENTIS discussion device
DICENTIS discussion device select language
DICENTIS discussion device voting
DICENTIS discussion device extended
DICENTIS Interpreter desk
DCNM-IDESKVID Interpreter desk with video
Bosch Security Systems B.V.
Hardware Installation Manual
2018.09 | V1.8 |
14
en | System installation overview
DICENTIS
Device
Node count
ARNI‑E OMNEO interface
ARNI‑S OMNEO interface
Tab. 3.1: Nodes count of DICENTIS equipment
An ARNI (Audio Routed Network Interface) is used to increase the number of DICENTIS
devices on a single subnet and to connect multiple DICENTIS system subnets. If more than
one subnet is required, two types of an ARNI must be used.
–
OMN-ARNIS (ARNI‑S OMNEO interface): The ARNI‑S is required for increasing the system
size above 100 DICENTIS devices. It supports up to 450 DICENTIS nodes in its subnet. It
also acts as a DHCP server in its subnet.
–
OMN-ARNI‑E (ARNI‑E OMNEO interface): The ARNI‑E is required for increasing the system
size above 450 DICENTIS nodes. It supports up to 450 DICENTIS nodes in its subnet. It
also acts as a DHCP server in its subnet. It can connect up to 40 subnets, each with an
ARNI‑S.
Defining subnets and subnet masks
A subnet is a logical, visible subdivision of an IP network. The number of DICENTIS devices
that can be in the same subnet depends on the subnet mask.
A standard class C subnet (255.255.255 or /24) can contain 254 IP addresses. Some
DICENTIS devices have 2 IP addresses. For this reason, Bosch advises to use 255.255.252.0
(or /22) as a subnet mask. This allows you to have 1018 IP addresses. The following table lists
the number of IP address per DICENTIS device in a DICENTIS Conference System.
2018.09 | V1.8 |
Device
IP addresses
DICENTIS server (optional Meeting Application)
Client PC running DICENTIS meeting application
DICENTIS Audio processor and powering switch
DICENTIS Powering switch
DICENTIS multimedia device
DICENTIS discussion device
DICENTIS discussion device select language
DICENTIS discussion device voting
DICENTIS discussion device extended
DICENTIS Interpreter desk
DCNM-IDESKVID Interpreter desk with video
ARNI‑Enterprise
ARNI‑Standard
IP camera
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
System installation overview | en
Device
IP addresses
SDI video switcher
15
Tab. 3.2: Nodes count of DICENTIS equipment
Maximum number of DICENTIS devices in a string:
–
The max age timer should be set to 22 when RSTP is used for cable redundancy to
prevent a defective cable or powering switch from influencing the system.
–
Each time data hops from one switch to another, the age is increased by one. This timer
can be reached or exceeded, because a daisy chain can be used to loop through the
DICENTIS devices.
–
This timer (or restriction) cannot be reached when there is no cable redundancy. This is
because the power limitation will be reached before the max age restriction is reached.
–
Bosch Security Systems B.V.
The timer can be reached when:
–
you use cable redundancy,
–
the system is incorrectly wired.
Hardware Installation Manual
2018.09 | V1.8 |
16
en | System installation overview
DICENTIS
Multi subnet DICENTIS Conference System
The following figure illustrates a typical multi subnet DICENTIS Conference System with a total
of 1200 DICENTIS devices.
–
The system is divided over four (4) subnets, where two (2) subnets having a maximum of
400 DICENTIS devices and an OMN-ARNIS are connected.
–
The system has one OMN-ARNIS installed in the first subnet with a maximum of 400
DICENTIS devices connected (Note that only one OMN-ARNIS is allowed within a multiple
subnet DICENTIS Conference System).
–
Subnet four (4): When using multiple subnets, make sure that all cameras needed to
capture video of the seats are all connected to the same subnet.
192.168.70.x
VLAN70
192.168.71.255
Internal DHPC server
Ports 13, 14, 15, 16
DICENTIS devices
Max. 420 nodes
OMN-ARNI-S
192.168.68.1
192.168.68.x
VLAN68
192.168.69.254
Ports 9, 10, 11, 12
Internet Router
192.168.1.254
DCNM-PS(2)
DICENTIS devices
Max. 420 nodes
192.168.1.x
VLAN74 (internet)
192.168.1.253
Ports 17, 18, 19, 20
OMN-ARNI-S
192.168.66.1
192.168.66.x
VLAN66
192.168.67.254
Ports 5, 6, 7, 8
DCNM-PS(2)
DICENTIS devices
Max. 420 nodes
OMN-ARNI-E
192.168.64.1
192.168.64.x
VLAN64
192.168.65.254
Ports 1, 2, 3, 4
L3 Switch
DCNM-APS(2)
DCNM server PC
Figure 3.3: Typical DICENTIS Conference System with multiple subnets
2018.09 | V1.8 |
–
1: External video switcher.
–
2: Dome camera.
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
System installation design and planning | en
17
System installation design and planning
Before you start to install system devices and connect system cabling, you should make a
system design and planning:
–
Familiarize yourself with the product and system capabilities.
–
Make a cable (connection) plan:
–
Calculate the system network cable length.
–
Calculate the system power consumption.
–
Calculate the required power capacity of the system.
Notice!
The DICENTIS Conference System uses the RSTP protocol when redundant cabling mode is
enabled. If the DICENTIS Conference System needs to be connected with the locally present
network, please consult the local IT department before continuing with the installation
design.
Notice!
Make sure that the cable lengths and power consumptions do not exceed the specifications.
Not doing so will result in malfunctioning at any moment of the DICENTIS Conference System
and products.
4.1
System capabilities
The capability of the DICENTIS Conference System and DICENTIS products depends on:
–
The lengths of the system network cables.
–
The number of connected devices.
–
The system power supply capacity.
Cable length
System network cables (DCNM‑CBxx-I) lengths (2, 5, 10 or 25 m) have a direct effect on the
available power supply capacity. The longer the system network cable, the less power supply
capacity is available to drive the connected devices. Therefore, choose the lengths of the
system network cables carefully.
Notice!
Custom network cables must never exceed the maximum Ethernet specification of 100m
(IEEE 802.3ab).
Keep your network hierarchy as flat as possible. This means having as few levels as possible.
It is recommended not to exceed 7 levels. See the following example: 1: 1st level = Root
switch, 2: 2 nd level = switch, 3: 3 rd level = switch.
Figure 4.1: Example: Switch-levels
Bosch Security Systems B.V.
Hardware Installation Manual
2018.09 | V1.8 |
18
en | System installation design and planning
DICENTIS
Power supply capacity
The total system network cable length and connected devices determine the required power
supply capacity. The power within the DICENTIS Conference System is supplied by:
–
The Audio processor and powering switch and the Powering switch, or
–
Off‑the‑shelf PoE Ethernet switches.
Calculation tool
The calculation tool can be used to calculate the total power capacity of the system. This
makes the design and planning of the DICENTIS Conference System easier. The calculation
tool uses the power consumption of the devices and the system network cable lengths to
calculate the needed system power supply capacity.
The calculation tool is on the DVD supplied with the Audio processor and powering switch and
is part of the DICENTIS software DCNM.iso file. The DCNM.iso file can be downloaded from
the Bosch website at: https://licensing.boschsecurity.com/software
2018.09 | V1.8 |
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
4.2
System installation design and planning | en
19
Hardware requirements
Switches
The following minimum requirements and recommendations apply to switches used in a
DICENTIS:
Requirement
Standard
Settings
Gbit Ethernet
IEEE802.3
Switch latency is maximally 10µSec with Gbit.
Valid for both copper and/or fiber ports.
Packet forwarding in
n.a.
If SW is responsible for packet switching, this would
HW per port
result in variable latency which is unacceptable.
>1.2Mpps
Quality of Service
DiffServ
With strict priority
To make sure PTP synchronization packets and
audio packets get priority over control packets.
OMNEO uses QoS on IP level to avoid
synchronization and audio problems on busy
networks. Although the system does work without
problems on relatively quiet networks (< 10%
network load) it is important to configure your
network switches correctly.
The used QoS is Differentiated Services or DiffServ,
which is part of the Type of Services field (ToS) in
the IP header. For more details on DiffServ & IP
header, see Wikipedia.
Warning: IEEE802.1p is also used for QoS, but is limited to layer 2. Since OMNEO uses IP
communication, this mechanism is not suitable, so make sure the used equipment uses
DiffServ QoS!
The table below gives an overview of the used DSCP values which need to be configured in
the switch:
Data
DSCP dec
DSCP hex
DSCP Label
TOS byte
Switch
(hex)
Priority
queue
PTP sync,
56
0x38
CS7
0xE0
Highest
46
0x2E
EF
0xB8
High
(reserved)
0x08
CS1
0x20
Low
Control
0x00
Best effort
0x00
None
delay req
PTP followup, delay
response,
audio
Warning: Please check thoroughly if your switch’s highest priority queue is label as #1 or e.g.
#8, because this may differ per brand. Unfortunately this is not consistent over the different
brands. Setting it wrong is worse than not having priority.
Bosch Security Systems B.V.
Hardware Installation Manual
2018.09 | V1.8 |
20
en | System installation design and planning
DICENTIS
Switches must be configured to support DiffServ (DSCP) quality of service The switch needs
to have 4 priority queues for the DiffServ mechanism to work.
Warning: Never use VOIP QoS settings!
Requirement
Standard
Settings
MAC table >1000
n.a.
To avoid the switch starts broadcasting unicast
packets because it runs out of space.
Disable EEE
IEEE 802.3az
Most implementations of EEE cause problems
because of implementation flaws. A good
implementation should work, but does not save
energy since the PTP synchronization avoids this.
Therefore, EEE must always be disabled.
Disable RSTP (when
Rapid Spanning Tree Protocol (RSTP) is required
no cable loops are
when (cable) loops are created for redundancy. When
used)
no loops are created, RSTP needs to be disabled for
optimal operation. When enabled, it can cause slow
connections to the switch.
Possibility to create
n.a.
VLANS
VLAN separation is recommended instead of IGMP
snooping, because most switches are unable to
handle the multicast changes in the system. Filtering
multicast data may be necessary for some devices,
such as 100 Mb devices (Sony cameras, TVOne, AMX,
and others).
IGMPv3 IGMPv2
IGMPv3 or IGMPv2 snooping. To optimize bandwidth
snooping in
usage, IGMP snooping can be used. This is useful in
hardware
systems with >10 multicast streams, although not
absolutely required. Sufficient performance for
handling a large number of IGMP query responses,
depends on the number of (directly or indirectly)
connected devices to that switch. Hardware support
for IGMP snooping is strongly recommended.
Requirements when Standard
Settings
Redundant wiring is
used
RSTP
IEEE802.1D-20 RSTP is used to allow the creation of loops for
04
redundancy. The switch must support changing the
following parameters to the listed values:
–
Hello_Time = 9 seconds
–
Forwarding_delay = 30 seconds
–
Max_age = 22 seconds
Diagnostics
2018.09 | V1.8 |
Link Layer discovery IEEE 802.1AB
For network diagnoses using Network Docent.
SNMP
For network diagnoses using Network Docent.
SNMP
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
System installation design and planning | en
21
Routers
The following minimal requirements apply to routers:
–
1 Gbit or higher Ethernet ports.
–
Supports PIM‑DM or Bidirectional PIM.
–
Performs IP routing in hardware (i.e. a ‘layer 3 switch’) to minimize the routing delay.
–
Packet forwarding rate > 1,000,000 packets per second per port (e.g. 8 Mpps for an
8‑port router).
–
Non-blocking backplane per switching port, i.e. 2 Gbit per port (e.g. 16 Gbps for an 8‑port
router).
–
Bosch Security Systems B.V.
MAC address table of at least 1000 addresses per directly connected subnet.
Hardware Installation Manual
2018.09 | V1.8 |
22
en | System installation design and planning
4.3
DICENTIS
Power supply capacity calculation plan
How to start
Notice!
It is advisable to use the power calculation tool. The calculation tool is on the DVD supplied
with the Audio processor and powering switch and is also part of the DICENTIS software
DCNM.iso file, which can be downloaded from the Bosch website at: https://
licensing.boschsecurity.com/software
Decide how to supply power to the DICENTIS devices:
–
Using the Audio processor and powering switch and one or more Powering switches.
–
Using one or more PoE Ethernet switches.
If you want to use PoE Ethernet switches, continue with chapter Calculation using PoE
switches, page 24.
See also
4.3.1
–
Calculation using DCNM-APS(2) or DCNM-PS(2), page 22
–
Installation material and tools, page 31
Calculation using DCNM-APS(2) or DCNM-PS(2)
Notice!
If you want to use customized cables, or a more accurate power supply capacity calculation
plan is needed, you should use the power calculation tool.
To calculate the total power supply capacity:
2018.09 | V1.8 |
1.
Count all DICENTIS devices.
2.
Know the exact location where the devices are installed.
3.
Count each system network cable of the same length.
Device type
Power consumption (Watts)
DCNM-D
3.10
DCNM-DSL
3.60
DCNM-DVT
3.70
DCNM-DE
5.00
DCNM-MMD
11.30
DCNM-MMD2
12.00
DCNM-IDESK
15.00
DCNM-IDESKVID
18.00
DCNM‑CB02-I
1.19
DCNM‑CB05-I
2.43
DCNM‑CB10-I
4.50
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
System installation design and planning | en
Device type
Power consumption (Watts)
DCNM‑CB25-I
10.71
23
Tab. 4.3: Power consumption (Watts)
Ordering number
Cable lengths
ft
DCNM-CB02-I
6.56
DCNM-CB05-I
16.40
DCNM-CB10-I
10
32.81
DCNM-CB25-I
25
82.02
Tab. 4.4: Cable types and lengths
Rear view
1 2 3 4 5 6 7 8
10
12
11
13
15
14
17
16
19
18
20
Figure 4.2: Audio processor and powering switch
10
12
13
14
15
16
17
18
19
20
Figure 4.3: Powering switch
Item
Description
1, 5
XLR line outputs 1 and 2.
2, 6
RCA line outputs 1 and 2.
3, 7
XLR line inputs 1 and 2.
4, 8
RCA line inputs 1 and 2.
Mains inlet, mains switch and fuse holder.
10
Reset button.
11
Ground switch (grounded or floating).
12
Socket 1 without power.
13
Socket 2 low power.
15, 17, 19
Socket 3, 4, 5 high power.
Bosch Security Systems B.V.
Hardware Installation Manual
2018.09 | V1.8 |
24
en | System installation design and planning
DICENTIS
Item
Description
14, 16, 18, 20
Overload LED for sockets 2‑5:
Green: Power OK.
Red: Overload. Remove cable and wait a few seconds for the system to
reset the overload.
Network and Power connector
Max. power output (W)
Max. devices
Socket 1 (12)
No power capacity
---
Socket 2 (13)
15
Socket 3 (15)
144
40
Socket 4 (17)
144
40
Socket 5 (19)
144
40
Tab. 4.5: Power supply capacity DCNM‑APS(2) / DCNM‑PS(2)
Calculation examples
The following example gives you an indication of the maximum load to each socket of an Audio
processor and powering switch or Powering switch.
–
Socket 2: 50 m cable + DCNM-MMD2 = 12 W1
–
Socket 3: 10 m cable + DCNM-MMD2 + 9x (2 m cable + DCNM-MMD2)
= (4.5 + 12) + 9x(1.19 + 12) = 135.21 W2.
–
Socket 4: 10 m cable + DCNM-D + 19x (2 m cable +DCNM-D)
= (4.5 + 3.1) + 19x(1.19 + 3.1) = 89.11 W2.
–
Socket 5: 10 m cable + DCNM-DE + 19x (2 m cable + DCNM-DE)
= (4.5 + 5) + 19x(1.19 + 5) = 127.11 W2.
4.3.2
For socket 2, the cable power consumption of the cable does not need to be counted if only one device is connected to this output.
The shortest redundant cable does not need to be counted.
Calculation using PoE switches
Select one or more PoE Ethernet switches to supply power to the DICENTIS devices. Each
DICENTIS device must be connected to an individual PoE enabled output of an Ethernet
switch.
Notice!
Some PoE Ethernet switches can only supply power to a limited number of ports. Others can
supply power to every port, but the total power the Ethernet switch can supply is limited.
Please consult the documentation of the PoE Ethernet switch used.
Notice!
Using PoE, DICENTIS devices cannot be daisy‑chained connected. Using PoE does not provide
redundant cabling.
2018.09 | V1.8 |
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
System installation design and planning | en
25
Figure 4.4: Bottom view DICENTIS devices (DCNM-MMD / DCNM-MMD2)
Figure 4.5: Bottom view DICENTIS devices (DCNM-D / DCNM-DVT / DCNM-DSL / DCNM-DE)
DCNM-IDESK
DCNM-IDESKVID
Figure 4.6: Bottom view DICENTIS Interpreter devices (DCNM-IDESK / DCNM-IDESKVID)
Item
Description
Network connector
Network / PoE connector
Bosch Security Systems B.V.
Hardware Installation Manual
2018.09 | V1.8 |
26
en | System installation design and planning
4.4
DICENTIS
Redundancy options
DICENTIS Conference Systems can be created with network redundancy. This ensures that the
system will continue to work if:
–
a network cable is defective or accidentally disconnected.
–
one of the components fails.
Different levels of redundancy can be created in the system depending on:
–
the type of unit used in the system (DCNM-APS / DCNM-PS or DCNM-APS2 / DCNM-PS2)
–
the number of redundant components used in the system.
–
the amount of redundant network cabling.
The following sections explain the redundancy options that can be used when designing your
DICENTIS Conference System. Each option can be combined in the DICENTIS Conference
System, providing you observe the redundant cabling limitations. Refer to:
–
Redundant cabling for DCNM‑APS/DCNM‑PS units, page 27.
–
Redundant cabling for DCNM-APS2/DCNM-PS2 units, page 28.
–
Redundant server PC, page 30.
Notice!
Rapid Spanning Tree Protocol (RSTP) must be enabled in the DICENTIS Conference System
for these redundancy options to work correctly.
Notice!
Follow these steps when setting up redundancy options for your system:
1.
First, set up your system without cable redundancy and RSTP configuration in the system
and DICENTIS.
2018.09 | V1.8 |
2.
Secondly, configure RSTP in the switches and DICENTIS.
3.
Thirdly, enable the cable loops.
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
4.4.1
System installation design and planning | en
27
Redundant cabling for DCNM‑APS/DCNM‑PS units
This section describes how to create redundant cabling for DCNM-APS or DCNM-PS units. The
maximum number of Ethernet devices in the loop (including the root switch) is 22. In a system
with no Ethernet switch(es), the APS is the root switch.
The total number of devices allowed in a loop depends on:
–
The type of device connected in the loop (for example, DCNM-MMD2 devices consume
more power than DCNM-DE devices).
–
The length of the loop (cable also consumes power).
The figure shows how to calculate the number of devices in the loop. The red line shows the
largest loop. The # sign shows the way the devices are counted.
In the example below up to 21 (22 - 1 = 21) discussion devices can be connected.
#1
#2
#22
Figure 4.7: DICENTIS devices connected with redundant cabling to the same DCNM-APS / DCNM-PS type
unit
1: DCNM-APS or DCNM-PS.
2: DICENTIS devices.
3: DICENTIS cabling (redundant loop).
Cabling possibilities (DCNM‑APS/DCNM‑PS) Limitations/requirements
Connect the DICENTIS devices in a daisy
The redundancy is for cable only. If the
chain configuration from a high power socket DCNM-PS or DCNM-APS fails, all DICENTIS
on a DCNM-PS or DCNM-APS to another high
devices connected to that unit will also fail.
power socket on the same DCNM-PS or
DCNM-APS.
If a single DICENTIS device fails, the other
DICENTIS devices in the daisy chain will
continue to work.
To enable redundancy, Rapid Spanning Tree
Protocol (RSTP) must be enabled.
You can use any of the high power sockets (3, The redundant loop must be connected to
4, or 5) to create the daisy chain.
the same DCNM-APS or same DCNM-PS.
See also
–
Bosch Security Systems B.V.
Power supply capacity calculation plan, page 22
Hardware Installation Manual
2018.09 | V1.8 |
28
en | System installation design and planning
4.4.2
DICENTIS
Redundant cabling for DCNM-APS2/DCNM-PS2 units
This section describes how to create redundant cabling for DCNM-APS2 / DCNM-PS2 type
units. The maximum number of Ethernet devices in the largest possible loop (including the
root switch) is 22. In a system with no Ethernet switch(es), the APS is the root switch.
The total number of devices allowed in a loop depends on:
–
The type of device connected in the loop (for example, DCNM-MMD2 devices consume
more power than DCNM-DE devices).
–
The length of the loop (cable also consumes power).
The figure shows how to calculate the number of devices in the loop. The red line shows the
largest loop. The # sign shows the way the devices are counted.
In the example below up to 19 (22 - 3 = 19) discussion devices can be connected.
#1
#22
#2
#3
#21
Figure 4.8: DICENTIS discussion devices connected with redundant cabling between DCNM-PS2 / DCNMAPS2 type units
1: DICENTIS system/client PC.
2: Network switch (with optional redundant power supply)
3: DCNM-APS2
4: DCNM-PS2
5: DICENTIS cabling (redundant loop)
Cabling possibilities (DCNM-APS2/DCNM-
Limitations/requirements
PS2)
Create a redundant loop by connecting the
The redundancy is for cable only. If the
DICENTIS devices in a daisy chain
DCNM-PS or DCNM-APS fails, all DICENTIS
configuration from a high power socket on a
devices connected to that unit will also fail.
DCNM-PS2 / DCNM-APS2 to a high power
socket on another DCNM-PS2.
To enable redundancy:
–
Rapid Spanning Tree Protocol (RSTP)
The redundant loop between two DCNM-PS2
must be enabled in the DICENTIS
units is for power and signal. If one of the
Conference System.
DCNM-PS2 units fails, the other DCNM-PS2
–
a network switch with redundant power
unit will supply power and signal to the
supply, should be connected to the
DICENTIS devices in the daisy chain.
DCNM-PS2 / DCNM-APS2 units, as
shown in the previous figure.
2018.09 | V1.8 |
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
System installation design and planning | en
Cabling possibilities (DCNM-APS2/DCNM-
29
Limitations/requirements
PS2)
You can use any of the high power sockets (3, Note: The redundant loop must be connected
4, or 5) on either of the DCNM-PS2 units to
to another DCNM-PS2 type unit. You cannot
create the daisy chain/redundant loop.
use DCNM-PS / DCNM-APS type units to
For example, high power socket 3 on one unit create redundant loops for power.
can be connected to high power socket 4 on
another unit.
You can create a redundant loop for signal
The redundant loop will function in the same
only, by connecting the DICENTIS devices in a way as a DCNM-PS / DCNM-APS type unit.
daisy chain configuration to the same DCNM-
Refer to Redundant cabling for DCNM‑APS/
PS2 or DCNM-APS2, although this is not
DCNM‑PS units, page 27.
recommended.
The DCNM-PS2 unit is designed to reduce
cost of ownership, for example, by allowing a
maximum of three redundant loops to be
connected between two DCNM-PS2 units.
Notice!
Rapid Spanning Tree Protocol (RSTP) must be enabled in the DICENTIS Conference System
for these redundancy options to work correctly.
See also
–
Bosch Security Systems B.V.
Power supply capacity calculation plan, page 22
Hardware Installation Manual
2018.09 | V1.8 |
30
en | System installation design and planning
4.4.3
DICENTIS
Redundant server PC
System availability can be improved by connecting a redundant DICENTIS server PC and the
associated components and cables to the DICENTIS Conference System. The maximum
number of Ethernet devices in the largest possible loop (including the root switch) is 22.
The total number of devices allowed in a loop depends on:
–
The type of device connected in the loop (for example, DCNM-MMD2 devices consume
more power than DCNM-DE devices).
–
The length of the loop (cable also consumes power).
The figure shows how to calculate the number of devices in the loop. The red line shows the
largest loop. The # sign shows the way the devices are counted.
In the example below up to 17 (22 - 5 = 17) devices can be connected.
#1
#2
#22
#3
#21
#4
#20
Figure 4.9: Redundant DICENTIS server PC with redundant components and cables
1: DICENTIS system/client PC
2: Network switch (with optional redundant power supply)
3: DCNM-APS2
4: DCNM-PS2
5: DICENTIS cabling (redundant loop)
For this option to work the DICENTIS Conference System has to be run in combination with
EverRun Enterprise software from Stratus Technologies. For more information, refer to the
Stratus Technologies website.
Other options that can be used for guaranteeing the reliability of the DICENTIS Conference
System include:
–
2018.09 | V1.8 |
Remote SQL servers.
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
Installation material and tools | en
31
Installation material and tools
This section describes installation material such as cables, connectors and tools.
Recommedations
–
Always use manufacturer specified installation products, materials and tools.
–
In general, use different cable ducts for the system network cables, audio cables and
mains supply cables.
–
In public areas where people can touch or move above the connectors and cables, use
metal protection covers.
Warning!
5.1
Do not exceed the bend limitations of system network cables (DCNM‑CBxxx):
The minimum bend radius of the system network cable is a 35 mm radius.
DICENTIS System Cable Assemblies
The DICENTIS System Cable Assemblies, terminated with connectors on both ends, are
available in different lengths and are used to connect DICENTIS devices to each other. The
cable consists of a low smoke zero halogen solid core.
Ordering number
Cable lengths
ft
DCNM-CB02-I
6.56
DCNM-CB05-I
16.40
DCNM-CB10-I
10
32.81
DCNM-CB25-I
25
82.02
Tab. 5.6: Cable types and lengths
Figure 5.1: DCNM-CBxx-I cable and connector view
Bosch Security Systems B.V.
Hardware Installation Manual
2018.09 | V1.8 |
32
en | Installation material and tools
5.2
DICENTIS
DCNM-CBCON Connectors for DICENTIS cable
The connectors are used to make your own system network cables or to replace a connector.
The cable can be used for solid core cable (DCNM-CB02-I, DCNM-CB05-I, DCNM-CB10-I,
DCNM-CB25-I, DCNM-CB250-I, DCNM-CB250), as well as stranded core cable (DCNM-CB02,
DCNM-CB05, DCNMCB10, DCNM-CB25, DCNM-CB02B, DCNM-CB05B, DCNM-CB10B, DCNMCB25B, DCNM-CB250B).
Figure 5.2: DCNM-CBCON Front and exploded view
Item
Description
Strain relief boot
Ferrule
Plug connector shield
Power contacts (Qty: 2)
Load bar
Power contact cavity (2 places)
Housing
Locking latch
Signal contact cavity (8 Places)
See also
2018.09 | V1.8 |
–
DICENTIS System Cable Assemblies, page 31
–
DCNM-CB250-I System Installation Cable, page 34
–
DCNM-CBTK System Network Cable Toolkit, page 33
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
5.3
Installation material and tools | en
33
DCNM-CBTK System Network Cable Toolkit
The system network cable toolkit is used to connect the DCNM-CBCON Connectors for
DICENTIS cable, page 32 to the DCNM-CB250-I System Installation Cable, page 34 or DICENTIS
System Cable Assemblies, page 31.
Item
Description
Power wiring tool.
Signal wiring tool.
Tab. 5.7: Toolkit content
Notice!
Please consult the “custom length for system network cables” section on the DVD, which can
be downloaded at: https://licensing.boschsecurity.com/software
Bosch Security Systems B.V.
Hardware Installation Manual
2018.09 | V1.8 |
34
en | Installation material and tools
5.4
DICENTIS
DCNM-CB250-I System Installation Cable
The system installation cable, without connectors, is available in a length of 250 meters and is
used for making your own system network cable. Refer also to the sections DCNM-CBCON
Connectors for DICENTIS cable, page 32 and DCNM-CBTK System Network Cable Toolkit, page
33.
Notice!
The maximum system network cable length is: 100 m / 328,9 ft.
Notice!
Please consult the “custom length for system network cables” section on the DVD, which can
be downloaded at: https://licensing.boschsecurity.com/software
See also
–
2018.09 | V1.8 |
DCNM-CBCON Connectors for DICENTIS cable, page 32
Hardware Installation Manual
Bosch Security Systems B.V.
DICENTIS
5.5
Installation material and tools | en
35
DCNM-CBCPLR Cable couplers
Cable couplers can be used:
–
to extend cables,
–
in a floor pod as break-out box,
–
as an interface between DICENTIS cable and “standard” CAT-5E cable combined with a
separate power cable,
–
to insert power locally to the participant devices,
–
to switch the system on by using two cable couplers and a switch.
Cable couplers are delivered in a box that contains 6 cable couplers. They can be used for all
types of DICENTIS cables.
5.5.1
Using a cable coupler to extend a cable
The DICENTIS Cable coupler can be used to extend cables, as it allows you to connect
DICENTIS Cable assemblies together. This way, it is possible to connect, for example, three 25
m (DCNM-CB25-I) cables together to form a 75 m cable.
Note:
–
The cable length is not allowed to exceed 100 m.
–
No more than 2 cable couplers can be used in one trunk.
DCNM-(A)PS
DCNM-(A)PS
5.5.2
Using a cable coupler as a break-out box
The DICENTIS Cable coupler can be used in a floor pod as a break-out box, for example, if you
want to connect temporary devices like a rostrum microphone. The cable coupler can be
fixated using the screw holes (2.5 mm) or via a tie wrap through the recessed area.
Note:
–
The cable length is not allowed to exceed 100 m.
–
No more than 2 cable couplers can be used in one trunk.
Bosch Security Systems B.V.
Hardware Installation Manual
2018.09 | V1.8 |
36
en | Installation material and tools
DICENTIS
DCNM-(A)PS
Installation in a floor pod as break-out box
5.5.3
Using a cable coupler as an interface between different types of cable
The cable coupler can be used as an interface between DICENTIS cable and “standard”
CAT-5E cable, optionally combined with a separate power cable. This can be used, for
example, when standard CAT-5E cabling coming from the technical room has to be connected
with DICENTIS cable in the conference room.
To set this up:
1.
Open the housing of the cable coupler.
2.
Connect the power cables to the screw terminals + and -.
3.
Remove the break-out of the housing to guide the power cables through.
4.
Create a tension release.
Warning!
Risk of electric shock. Exposed power cables are a potential hazard. Make sure all power
cables are securely fastened by fixing them with a tie wrap on the inside of the box (see
drawing ‘Creating a tension relief’).
5.
Close the housing and fix the screw with torque 0.4 Nm.
Note:
2018.09 | V1.8 |
–
The cable length is not allowed to exceed 100 m.
–
No more than 2 cable couplers can be used in one trunk.
Hardware Installation Manual
Bosch Security Systems B.V.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Modify Date                     : 2018:10:11 13:49:54+02:00
Creator                         : pdfsam-console (Ver. 2.4.1e)
Create Date                     : 2018:10:11 13:49:54+02:00
Producer                        : iText 2.1.7 by 1T3XT
Page Count                      : 36
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UX8-DCNM-IDESKX

Navigation menu