Bosch Security Systems DCNMDX DICENTIS Discussion devices User Manual Hardware Installation Manual
Bosch Security Systems BV DICENTIS Discussion devices Hardware Installation Manual
Contents
- 1. Users Manual_Part 1
- 2. Users Manual_Part 2
Users Manual_Part 2
26 en | Installation material and tools DICENTIS Installation material and tools This section describes installation material such as cables, connectors and tools. Recommedations – Always use manufacturer specified installation products, materials and tools. – In general, use different cable ducts for the system network cables, audio cables and mains supply cables. – In public areas where people can touch or move above the connectors and cables, use metal protection covers. Warning! 5.1 Do not exceed the bend limitations of system network cables (DCNM‑CBxxx): The minimum bend radius of the system network cable is 50 mm radius. System Network Cable The system network cables, terminated with connectors on both ends, are available in different lengths and are used to connect DICENTIS devices to each other. The cable consists of four CAT‑5e twisted pairs to transmit data and two copper wires to supply the power. Ordering number Cable lengths ft DCNM-CB02 6.56 DCNM-CB05 16.40 DCNM-CB10 10 32.81 DCNM-CB25 25 82.02 Table 5.1: Cable types and lengths Figure 5.1: DCNM-CBxx cable and connector view 2016.07 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V. DICENTIS Installation material and tools | en 5.2 27 System Cable Connectors The connectors are used to make your own system network cables or to replace a connector. Two types of system cable connectors are available: DCNM-CBCON-I Installation Cable Connectors, page 28 and DCNM-CBCON-N Network Cable Connectors, page 28. Caution! Both connector types look similar but are different! So, only use the right type of connector with the right type of system cable. Figure 5.2: DCNM-CBCON Front and exploded view Item Description Strain relief boot Ferrule Plug connector shield Power contacts (Qty: 2) Load bar Power contact cavity (2 places) Housing Locking latch Signal contact cavity (8 Places) See also – System Network Cable, page 26 – DCNM-CB250 System Installation Cable, page 30 – DCNM-CBTK System Network Cable Toolkit, page 29 Bosch Security Systems B.V. Hardware Installation Manual 2016.07 | V1.4 | 28 en | Installation material and tools 5.2.1 DICENTIS DCNM-CBCON-I Installation Cable Connectors The DICENTIS 50 Installation Cable Connectors DCNM‑CBCON‑I can only be used with the the DCNM-CB250 System Installation Cable, page 30 by using the DCNM-CBTK System Network Cable Toolkit, page 29. 5.2.2 DCNM-CBCON-N Network Cable Connectors The DICENTIS 50 Network Cable Connectors DCNM‑CBCON‑N can only be used with the System Network Cable, page 26 by using the DCNM-CBTK System Network Cable Toolkit, page 29. 2016.07 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V. DICENTIS 5.3 Installation material and tools | en 29 DCNM-CBTK System Network Cable Toolkit The system network cable toolkit is used to connect the System Cable Connectors, page 27 to the DCNM-CB250 System Installation Cable, page 30 or System Network Cable, page 26. Item Description Power wiring tool. Signal wiring tool. Table 5.2: Toolkit content Notice! Please consult the “custom length for system network cables” section on the DVD, which can be downloaded at: https://licensing.boschsecurity.com/software Bosch Security Systems B.V. Hardware Installation Manual 2016.07 | V1.4 | 30 en | Installation material and tools 5.4 DICENTIS DCNM-CB250 System Installation Cable The system installation cable, without connectors, is available in a length of 250 meters and is used for making your own system network cable. Refer also to the sections System Cable Connectors, page 27, DCNM-CBCON-I Installation Cable Connectors, page 28 and DCNM-CBTK System Network Cable Toolkit, page 29. Notice! The maximum system network cable length is: 100 m / 328,9 ft. Notice! Please consult the “custom length for system network cables” section on the DVD, which can be downloaded at: https://licensing.boschsecurity.com/software See also – 2016.07 | V1.4 | System Cable Connectors, page 27 Hardware Installation Manual Bosch Security Systems B.V. DICENTIS Mechanical installation of Central Equipment | en Mechanical installation of Central Equipment 6.1 Audio Powering Switch and Powering Switch 31 The Audio Powering Switch is used: – to control system audio signals, – to route audio signals to/from devices, – to supply power to devices, – as an Ethernet switch to connect the PC and DICENTIS devices (DCNM-D / DCNM-DVT / DCNM-DSL / DCNM-DE / DCNM-MMD / DCNM-MMD2). The Powering Switch is used to: – supply power to devices. Scope of delivery The Audio Powering Switch and Powering Switch are shipped with the following parts: – 1x Mains power cord. – 1x Safety instructions. – 1x Set of 19 inch mounting brackets. – 4x bottom feet. – 1x DVD containing manuals and software (only with Audio Powering Switch). Front view Figure 6.1: Audio Powering Switch / Powering Switch Item Description 19“ mounting brackets. Ventilation inlet. Indication LED: Off: Switched off. Green: Switched on. Amber: Standby. Blinking: Services on the server PC are not running. Alternating green amber: When a software download is required. Bosch Security Systems B.V. Hardware Installation Manual 2016.07 | V1.4 | 32 en | Mechanical installation of Central Equipment DICENTIS Rear view 1 2 3 4 5 6 7 8 10 12 11 13 15 14 17 16 19 18 20 Figure 6.2: Audio Powering Switch 10 12 13 14 15 17 16 18 19 20 Figure 6.3: Powering Switch Item Description 1, 5 XLR line outputs 1 and 2. 2, 6 RCA line outputs 1 and 2. 3, 7 XLR line inputs 1 and 2. 4, 8 RCA line inputs 1 and 2. Mains inlet, mains switch and fuse holder. 10 Reset button. 11 Ground switch (grounded or floating). 12 Socket 1 without power. 13 Socket 2 low power. 15, 17, 19 Socket 3, 4, 5 high power. 14, 16, 18, 20 Overload LED for sockets 2‑5: Green: Power OK. Red: Overload. Remove cable and wait a few seconds for the system to reset the overload. 2016.07 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V. DICENTIS Mechanical installation of Central Equipment | en 33 How to install 1. Install the Audio Powering Switch or Powering Switch in a 19 inch device rack system or on a flat surface. Two 19 inch mounting brackets and four bottom feet are supplied with the Audio Powering Switch and Powering Switch. Refer to the following illustration. 2. Connect all required cabling. 3. Connect the mains supply. Figure 6.4: 19 inch rack, flat surface and feet mounting Item Description 19 inch rack mounting (bracket) Flat surface mounting (bracket) Feet mounting Notice! The unit extends 30 mm in front of the 19” mounting brackets when installed in a 19” rack system. Caution! Do not obstruct the airflow vents on the front side and rear left and right sides. Bosch Security Systems B.V. Hardware Installation Manual 2016.07 | V1.4 | 34 en | Mechanical installation of Contribution Devices DICENTIS Mechanical installation of Contribution Devices 7.1 DICENTIS devices The DICENTIS devices (DCNM-D, DCNM-DVT, DCNM-DSL, DCNM-DE, DCNM-MMD, DCNMMMD2) are used to: – participate in a meeting or conference. – monitor and control a meeting or conference (chairperson use, depending on the configuration). DCNM-MMD / DCNM-MMD2 10 Figure 7.1: Front, top, rear and side views 2016.07 | V1.4 | Item Description 7” capacitive touch screen. LED strip. Two‑way loudspeaker. 3.5 mm stereo jack for headphone or headset with integrated microphone. Headphone volume control. Microphone request button. Chairperson priority or microphone mute button. Near Field Communication (NFC) reader (DCNM-MMD2 only). Cable guides. 10 Microphone input connector. Hardware Installation Manual Bosch Security Systems B.V. Mechanical installation of Contribution Devices | en DICENTIS 35 DCNM-D / DCNM-DVT / DCNM-DSL / DCNM-DE Figure 7.2: Front, top, rear and side views Item Description Two‑way loudspeaker. Near Field Communication (NFC) reader. Chairperson priority button, microphone mute button, or microphone request button for second participant. Microphone request button. Voting buttons. Language selection buttons. Language display. 4.3” capacitive touch screen. 3.5 mm stereo jack for headphone or headset with integrated microphone. 10 Headphone volume control. 11 Microphone input connector. 12 Cable guides. Bosch Security Systems B.V. Hardware Installation Manual 2016.07 | V1.4 | 36 en | Mechanical installation of Contribution Devices DICENTIS Connecting DICENTIS devices The DICENTIS Conference System can be quickly and easily configured as a daisy‑chain configuration or as a star configuration: – Daisy‑chain configuration: Uses dedicated cabling, consisting of CAT‑5e cables including – Star configuration: Each DICENTIS device is connected with an individual standard two additional power conductors (see Typical system setup, page 8). CAT‑5e cable. An Ethernet switch is also required for providing Power over Ethernet (PoE). Notice! When Power over Ethernet is used, DICENTIS devices cannot be daisy‑chained. The star configuration makes use of connectors underneath the devices, ensuring for a neat, tidy system installation, especially advantageous for TV coverage. To connect the system network cables to the DICENTIS devices (refer to the following figure): 1. Insert the system network cable/connector (2). 2. Lead the system network cable through the cable guides (3). Installing DICENTIS devices The DICENTIS devices can be free-standing or fixed in more permanent installations using mounting screws. 1. The distance between the centres of the screw inserts (1) on the bottom is 100 mm. 2. Use M4 type of screws with a device screw insert length of maximum 5 mm when attaching the device to the bottom of the recess (1). Figure 7.3: Bottom view discussion DICENTIS devices (DCNM-MMD / DCNM-MMD2) 2016.07 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V. Mechanical installation of Contribution Devices | en DICENTIS 37 Figure 7.4: Bottom view DICENTIS devices (DCNM-D / DCNM-DVT / DCNM-DSL / DCNM-DE) Item Description Screw insert for fixed installation. 2x RJ45 connection input/output for system power cable. Cable guides. USB connector, for future use (DCNM-MMD / DCNM-MMD2 only). See also – System Network Cable, page 26 – DCNM-CB250 System Installation Cable, page 30 Bosch Security Systems B.V. Hardware Installation Manual 2016.07 | V1.4 | 38 en | Mechanical installation of Contribution Devices 7.2 DICENTIS DICENTIS Microphones Both the DCNM‑HDMIC High Directive Microphone and DCNM-MICL/S Stem Microphone are typically used with the DICENTIS devices. Figure 7.5: DCNM‑HDMIC and DCNM‑MICS / DCNM‑MICL front and bottom view 2016.07 | V1.4 | Number Description LED indicator. Microphone grill. Adjustable stem (DCNM‑MICS / DCNM‑MICL). Connection guidance. Slider guidance. Connector plug. Lock-slider for lock release (Press and shift to release). Lock. Device female connector (see following figure). Hardware Installation Manual Bosch Security Systems B.V. Mechanical installation of Contribution Devices | en DICENTIS 39 How to connect or remove the microphone The microphone can be easily connected to the DICENTIS devices: 75 8 Figure 7.6: DCNM‑HDMIC or DCNM-MICS / DCNM-MICL connection To do so: 1. Gently guide the connection guidance (4) into the DICENTIS device microphone connector (9). 2. Gently push the connector plug (6) into the device microphone connector (9) until the connection lock (5) fits/click into place. 3. To remove the microphone from the device: Shift lockslider (7) towards the device and hold in place lock release (8) and pull out the microphone. See also – Bosch Security Systems B.V. DICENTIS devices, page 34 Hardware Installation Manual 2016.07 | V1.4 | 40 en | Mechanical installation of Contribution Devices 7.3 DICENTIS DCNM-MMDSP Anti-reflection foil The DICENTIS anti‑reflection foil can be used to protect the tempered glass screen of a DICENTIS multimedia Device. Installation procedure 1. Use the included alcohol swab and the microfiber fabric to clean the device LCD screen before installation. 2. Peel the positioning adhesive release paper from the rear of anti‑reflection foil. 3. Position the anti‑reflection foil on the device LCD screen, and then fix the positioning adhesive to the side of the device. 4. Open the anti‑reflection foil, and use the “cleaning stick” to clean surface dust from the LCD screen. 5. Peel the protective film from the other side of the anti‑reflection foil. 6. Lightly press the anti‑reflection foil on to the LCD screen. If air bubbles are trapped under the anti‑reflection foil, use the “squeegee” to remove them. 7.4 DCNM-NCH Name Card Holder The name card holder (1) can be used to permanently display the participant’s name on the rear of a DICENTIS multimedia Device. The name card holder has two magnets (2) that allow it to be easily attached to, and removed from, the rear of the device. Figure 7.7: DCNM‑NCH assembly Item Description Name card holder. Magnets. Notice! A paper insert template is included on the DVD that can be downloaded at: https:// licensing.boschsecurity.com/software 2016.07 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V. DICENTIS Installation Test | en 41 Installation Test An installation test is needed to prevent connection mismatches and find potential product defects at an early stage. Not to do so could result in a system malfunctioning. Each DICENTIS device has its own built‑in diagnostics, which can be used for faultfinding. The diagnostics starts as soon the DICENTIS device is powered on. The DICENTIS Conference System does not have to be configured with, and connected to, the system controller PC. Preconditions 1. All system network cables are connected to the devices. 2. The Audio Powering Switch and Powering Switch(es) are installed. Start the test Power on the Audio Powering Switches and Powering Switches used in the system: Each connected device powers on and initializes. 1. After the DICENTIS multimedia Device and the DICENTIS discussion Extended have initialized, the diagnostic screen is shown. 2. If the text “Link down” is shown: – The network cable is not connected or defective. – The device is only connected with one system network cable (“Link down” is shown on the side where the device is not connected). 3. If the system network cable is correctly connected to the network, the network speed is shown. 4. If the DICENTIS multimedia Device and the DICENTIS discussion Extended are connected to an Audio Powering Switch, Powering Switch or another multimedia device, and 100 Mb is shown: – Not all wiring inside the system network cable connector is correctly connected or broken. You need to check the wiring and connector. – If the cable is connected to a 100 Mb switch, it is correct. 5. Click the info button to see additional information of the multimedia device. 6. When everything is correctly connected, and the device does not have the application software, it shows the text “Please download software”. 7. Bosch Security Systems B.V. Now the device can be downloaded: Hardware Installation Manual 2016.07 | V1.4 | 42 en | Installation Test DICENTIS – Downloading devices is not covered in this manual. Refer to the DICENTIS configuration manual on how to download the devices. Customer service If a fault cannot be resolved, please contact your supplier or system integrator, or go directly to your Bosch representative. 2016.07 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V. Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven Netherlands www.boschsecurity.com © Bosch Security Systems B.V., 2016
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2016:07:18 18:46:11+01:00 Creator : AH Formatter V5.3 MR3 (5,3,2011,1116) for Windows (x64) Modify Date : 2016:08:16 10:49:17+02:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : AH Formatter V5.3 MR3 (5,3,2011,1116) for Windows (x64) Metadata Date : 2016:08:16 10:49:17+02:00 Producer : Antenna House PDF Output Library 2.6.0 (Windows (x64)) Trapped : False Format : application/pdf Title : Hardware Installation Manual Document ID : uuid:8d85fde1-1ea2-4c27-b15d-6292eaa9cbfe Instance ID : uuid:c840148f-de3c-47cd-af1f-e95fb0482325 Page Mode : UseOutlines Page Count : 19EXIF Metadata provided by EXIF.tools