Brooks Automation UF70 RFID UHF Reader User Manual Product Manual
Brooks Automation (Germany) GmbH RFID Division RFID UHF Reader Product Manual
Contents
- 1. Installation Guide
- 2. User Manual
- 3. RF Exposure statement
User Manual
En glish Pr odu ct M a n u a l RFI D Re a de r UF7 0 Ce r t u m The product m anual m ust be read prior t o t he init ial st art- up. Observe t he safet y inst ruct ions! St ore for fut ure use. This docum ent at ion is not subj ect t o revisions. I D120037 05/ 2012 I nform ation This product m anual corresponds wit h " Direct ive 1999/ 5/ EC of t he European Parliam ent and t he Council on radio equipm ent and t elecom m unicat ions t ransm ission equipm ent and t he m ut ual recognit ion of t he conform it y" . This product m anual is addressed t o t he operat ing com pany who m ust pass it on t o t he personnel responsible for inst allat ion, connect ion, use and repairs of t he m achine. The plant m anager m ust ensure t hat t he inform at ion cont ained in t his product m anual and in t he accom panying docum ent s has been read and underst ood. The product m anual m ust be st or ed in a place t hat is fam iliar and easily accessible t o em ployees and m ust be consult ed whenever an em ployee is unsure of how t o proceed. The m anufact urer does not assum e any r esponsibilit y for inj uries t o persons or anim als, or dam age t o propert y or t o t he device arising fr om incor rect use or disregard or insufficient considerat ion of t he safet y crit eria cont ained in t his product m anual or based on m odificat ions of t he device or t he use of unsuit able spare part s. The copyright for t his product m anual is held solely by Brooks Aut om at ion ( Germ any) Gm bH RFI D Division Gart enst r. 19 95490 Mist elgau Ger m any or it s legal successor. Reproducing or circulat ing t his product m anual is only perm it t ed wit h t he exclusive approval of t he copyright holder. This also applies if only excerpt s of t he product m anual are copied or circulat ed. These r equirem ent s also apply for circulat ing t he product m anual in digit al form . St at us: May 2012 I nform ation Ar ch i v i n g St ore t he product m anual in t he vicinit y of t he device! Always keep t he product m anual handy! Sy m b o l s a n d si g n a l w o r d s The following sym bols and signal words are used in t his docum ent at ion. The com binat ion of a pict ograph and a signal word classifies t he respect ive safet y inform at ion. The sym bol can vary depending on t he t ype of danger. Si g n a l w o r d D e scr i p t i o n D AN GER This signal word m ust be used if deat h or irreversible dam age t o healt h can occur if t he hazard inform at ion is not followed. W ARN I N G This signal word indicat es bodily inj uries and propert y dam age including inj uries, accident s, and healt h risks. CAUTI ON This signal word indicat es a risk of propert y dam age. I n addit ion, t here is a slight risk of inj uries. ATTEN TI ON This signal word warns of m alfunct ions and m ay only be used if no dam age t o healt h can occur. I M PORTAN T This signal word indicat es crossreferences and ways in which operat ions are facilit at ed. I t excludes all risks of propert y dam age and inj ury risks. No dam age R i sk o f i n j u r y a n d propert y dam age Death Sy m b o l I nform ation Ta r ge t gr oup This product m anual is addressed t o personnel wit h t he following areas of responsibilit y: A r e a o f r e sp o n si b i l i t y Co m p e t e n ce I nst allat ion Specialized personnel Com m issioning, operat ion and decom m issioning I nst ruct ed personnel Troubleshoot ing Specialized personnel Definit ion according t o DI N EN 60204- 1: I n st r u ct e d p e r so n n e l Persons who have been inst ruct ed and, if required, t rained by a specialist as t o t he t asks assigned t o t hem , t he possible risks of incorrect behavior and t he required safet y equipm ent and safet y m easures. Sp e ci a l i z e d p e r so n n e l Persons who can evaluat e t he work assigned t o t hem and recognize possible risks based on t heir specialized t raining, knowledge, experience and fam iliarit y wit h t he relevant st andards. Co n t e n t s I d e n t i f i ca t i o n . . . . . . . . . . . . . . . . . . . . . . . . . 7 1 .1 D e sign a t e d u se 1 .2 I n cor r e ct u se D e cl a r a t i o n o f Co n f o r m i t y Ge n e r a l I n st r u ct i o n s . . . . . . . . . . . . . . . 10 . . . . . . . . . . . . . . . . . . . 12 3 .1 Lia bilit y a nd w a r r a nt y 12 3 .2 Obj e ct ive s of t he pr oduct m a n u a l 12 Sa f e t y I n st r u ct i o n s . . . . . . . . . . . . . . . . . . . . 14 4 .1 Ar e a of a pplica t ion a nd sym bols 14 4.1.1 Safet y sym bols – in com pliance wit h 4844- 2 15 4.1.2 Warning sym bols 15 4.1.3 Prohibit ion sym bols 15 4.1.4 Ot her sym bols 16 4 .2 Obliga t ion s 17 4.2.1 Operat ing com pany’s obligat ions 17 4.2.2 Operat ing personnel’s obligat ions 17 4 .3 ESD inst r uct ions 18 4 .4 Re sidu a l r isk s 18 4 .5 Addit iona l infor m a t ion 20 P r o d u ct Sp e ci f i ca t i o n s . . . . . . . . . . . . . . . . . . 2 2 5 .1 Fu nct ion 22 5 .2 I m a ge s 23 5.2.1 Front view 23 5.2.2 Rear view 24 5.2.3 Top view 25 5 .3 D e scr ipt ion of t he com pon e n t s 26 5 .4 Te ch n ica l da t a 28 I n st a l l a t i o n . . . . . . . . . . . . . . . . . . . . . . . . . . 3 0 6 .1 Sa fe t y inst r uct ions 30 6 .2 Qua lifie d inst a lla t ion pe r sonne l 32 6 .3 Un pa ck in g 32 6 .4 Asse m bly of t he de vice 33 6 .5 Ant e nna inst a lla t ion 34 Co n t e n t s 10 6.5.1 Posit ioning t he ant enna 34 6.5.2 Available ant enna t ypes 34 6 .6 Pow e r supply 34 6 .7 Te r m in a l con n e ct ion 35 6 .8 Ex t e r n a l inpu t a n d out pu t ( opt ion a l) 36 6 .9 Com m ission ing 36 6.9.1 Required operat ing condit ions 36 6.9.2 Param et ers of t he serial int erface 36 6.9.3 Param et ers of t he Et hernet int erface 37 Ope r a t ion . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 7 .1 Ope r a t ing pe r sonne l 40 7 .2 Com m un ica t ion pr ot ocol ASC- I 1 40 7.2.1 St ruct ure of t he com m unicat ion prot ocol 40 7.2.2 Package cont ent s 41 7.2.3 Com m ands of prot ocol 43 7.2.4 Param et ers 126 7 .3 Addit iona l infor m a t ion 155 Se r v i ce a n d T r o u b l e sh o o t i n g . . . . . . . . . . . . 156 8 .1 Ge ne r a l r e m a r k s 156 8 .2 Qua lifie d t r ouble sh oot in g pe r son n e l 157 8 .3 Sa fe t y inst r uct ions 157 8 .4 Er r or code s 158 8 .5 Er r or displa y w it h LED 160 8 .6 Re a de r doe s n ot r e spond 160 8 .7 Re se t 161 8 .8 Pow e r cu t 161 8 .9 Soft w a r e r e le a se s 161 8 .1 0 Cu st om e r se r vice 161 D i sm a n t l i n g a n d St o r a g e . . . . . . . . . . . . . . . 162 9 .1 D ism a n t lin g 162 9 .2 St or a ge 162 T r a n sp o r t a n d D i sp o sa l . . . . . . . . . . . . . . . . 163 1 0 .1 Tr a nspor t 163 1 0 .2 D isposa l 163 Ch a p t e r 1 I de nt ifica t ion I d e n t if ica t io n This chapt er gives you an overview of t he following t opics: M ode l ■ Designat ed use ■ I ncorrect use RFI D Reader UF70 Cert um Serial num ber 00 – 0001 – UF70 Part num ber TUG- E1ML- 4O00- F4- 00E1 ETSI version, prot ect ion class I P40 TFG- E1ML- 4O00- F4- 00E1 FCC version, prot ect ion class I P40 TUG- E1ML- 4O00- R4- 00E1 ETSI version, prot ect ion class I P65 TFG- E1ML- 4O00- R4- 00E1 FCC version, prot ect ion class I P65 M a n u fa ct u r e r Brooks Aut om at ion ( Germ any) Gm bH RFI D Division Gart enst r. 19 D- 95490 Mist elgau GERMANY Telephone + 49 ( 0) 9279 - 991 550 Fax E- m ail Websit e + 49 ( 0) 9279 - 991 501 info.rfid@brooks.com www.brooks- rfid.com For inform at ion on t he label, see Device label. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m Ch a p t e r 1 I de nt ifica t ion 1 .1 D e sig n a t e d u se This product is exclusively developed for reading and writ ing of passive UHF t ransponders ( e.g. EPC Class1 Gen2) . Any ot her use of t his device const it ut es m isuse and renders t he user's aut horit y t o inst all and operat e t he device invalid. This product is designed t o be m ount ed and operat ed in an indust rial set t ing as a built- in- device only. I t is not designed t o be used as a st and- alone or port able device or in a non- indust rial set t ing, such as a household, vehicle or in t he openair. I nt ended use also includes t he following: ■ following all inst ruct ions in t he product m anual ■ following all safet y inform at ion nbb Before using t he device, t he user should ensure t hat t he nat ional approval requirem ent s for use are m et . Use r infor m a t ion FCC I M PORTAN T Changes or m odificat ions not expressly approved by t he part y responsible for com pliance could void t he user ’s aut horit y t o operat e t he equipm ent . This equipm ent has been t est ed, and found t o com ply wit h t he lim it s for a Class A digit al device, pursuant t o part 15 of t he FCC Rules. These lim it s are designed t o provide reasonable prot ect ion against harm ful int erference when t he equipm ent is operat ed in a com m ercial environm ent . This equipm ent generat es, uses, and can radiat e radio frequency energy and, if not inst alled and used in accordance wit h t he inst ruct ion m anual, m ay cause harm ful int erference t o radio com m unicat ions. Operat ion of t his equipm ent in a resident ial area is likely t o cause harm ful int erference, in which case t he user will be required t o correct t he int erference at his own expense. 1 .2 I n co r r e ct u se I ncorrect use, which can endanger t he device, t he user and t hird part ies, includes: ■ t he use of t he device, cont rary t o it s int ended use ( Designat ed use) ■ m odifying, ext ending or reconst ruct ing t he device wit hout first consult ing Brooks Aut om at ion ( Germ any) Gm bH ■ operat ing t he device when t here are obvious problem s Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m Ch a p t e r 1 I de nt ifica t ion W ARN I N G R i sk o f i n j u r y t h r o u g h i n co r r e ct m o d i f i ca t i o n s There are risks from unaut horized m odificat ions t o t he m achine. Only use original spare part s from t he m anufact urer. Do not m ake any changes, at t achm ent s or m odificat ions t o t he device wit hout t he approval of Brooks Aut om at ion ( Germ any) Gm bH. W ARN I N G R i sk o f i n j u r y a n d m a l f u n ct i o n o f m a ch i n e o p e r a t i o n t h r o u g h i n co r r e ct u se There are risks at t ached t o using t he device incorrect ly. Use t he device exclusively according t o it s int ended use. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m Ch a p t e r 2 D e cl a r a t i o n o f Co n f o r m i t y D e cl a r a t i o n o f Co n f o r m i t y Ko n f o r m i t ä t se r k l ä r u n g g e m ä ß d e m Ge se t z ü b e r Fu n k a n l a g e n u n d T e l e k o m m u n i k a t i o n se n d e i n r i ch t u n g e n ( FT EG) u n d d e r R i ch t l i n i e 1 9 9 9 / 5 / EG ( R & T T E) Declarat ion of Conform it y in accordance wit h t he Radio and Telecom m unicat ions Term inal Equipm ent Act ( FTEG) and Direct ive 1999/ 5/ FC ( R&TTE Direct ive) Herst eller / Verant wort liche Person Manufact urer / responsible person BR O O KS Au t o m a t i o n ( Ge r m a n y ) Gm b H / H e r r D i t t r i ch erklärt , dass das Produkt declares t hat t he product U F7 0 Ce r t u m Type ( ggf. Anlagenkonfigurat ion m it Angabe der Module) Type ( if applicable, configurat ion including t he m odules) Telekom m unikat ions( Tk- ) endeinricht ung Telecom m unicat ions t erm inal equipm ent Funkanlage Radio equipm ent Verwendungszweck I nt ended purpose I d e n t i f i ca t i o n sy st e m Gerät eklasse Equipm ent class bei best im m ungsgem äßer Verwendung den grundlegenden Anforderungen des § 3 und den übrigen einschlägigen Best im m ungen des FTEG ( Art ikel 3 der R&TTE) ent spricht . com plies wit h t he essent ial requirem ent s of § 3 and t he ot her relevant provisions of t he FTEG ( Art icle 3 of t he R&TTE Direct ive) , when used for it s int ended purpose. Ge su n d h e i t u n d Si ch e r h e i t g e m ä ß § 3 ( 1 ) 1 . ( A r t i k e l 3 ( 1 ) a ) ) Healt h and safet y requirem ent s pursuant t o § 3 ( 1) 1. ( Art icle 3( 1) a) ) angewendet e harm onisiert e Norm en Harm onized st andards applied Einhalt ung der grundlegenden Anforderungen auf andere Art und Weise ( hierzu verwendet e St andards/ Spezifikat ionen) Ot her m eans of proving conform it y wit h t he essent ial requirem ent s ( st andards / specificat ions used) Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m EN 6 0 9 5 0 - 1 : 2 0 0 6 - - - 10 Ch a p t e r 2 D e cl a r a t i o n o f Co n f o r m i t y Sch u t z a n f o r d e r u n g e n i n Be z u g a u f d i e e l e k t r o m a g n e t i sch e V e r t r ä g l i ch k e i t ( § 3 ( 1 ) 2 , A r t i k e l 3 ( 1 ) b ) Prot ect ion requirem ent s concerning elect rom agnet ic com pat ibilit y § 3( 1) ( 2) , ( Art icle 3( 1) ( b) ) EN 3 0 1 4 8 9 - 1 V1 .8 .1 EN 3 0 1 4 8 9 - 3 V1 .4 .1 angewendet e harm onisiert e Norm en Harm onized st andards applied Einhalt ung der grundlegenden Anforderungen auf andere Art und Weise ( hierzu verwendet e St andards/ Spezifikat ionen) Ot her m eans of proving conform it y wit h t he essent ial requirem ent s ( st andards / int erface specificat ions used) M a ß n a h m e n z u r e f f i z i e n t e n N u t z u n g d e s Fu n k f r e q u e n z sp e k t r u m s Measures for t he efficient use of t he radio frequency spect rum Luft schnit t st elle bei Funkanlagen gem äß § 3( 2) ( Art ikel 3( 2) ) Air int erface of t he radio syst em s pursuant t o § 3( 2) ( Art icle 3( 2) ) angewendet e harm onisiert e Norm en Harm onized st andards applied EN 3 0 2 2 0 8 - 1 V1 .3 .1 EN 3 0 2 2 0 8 - 2 V1 .3 .1 Einhalt ung der grundlegenden Anforderungen auf andere Art und Weise ( hierzu verwendet e St andards/ Spezifikat ionen) Ot her m eans of proving conform it y wit h t he essent ial requirem ent s ( st andards/ specificat ions used) - - - BROOKS Aut om at ion ( Germ any) Gm bH Gart enst r. 19 D- 95490 Mist elgau GERMANY Telephone Fax E- Mail + 49 ( 0) 9279 - 991 550 + 49 ( 0) 9279 - 991 501 info.rfid@brooks.com Mist elgau, July 21, 2011 ( Place and dat e of issue) Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m Gerald Dit t rich ( Nam e and signat ure) 11 nbb Ch a p t e r 3 Ge ne r a l I nst r uct ions Ge n e r a l I n st r u ct io n s This chapt er gives you an overview of t he following t opics: ■ Liabilit y and warrant y ■ Obj ect ives of t he product m anual 3 .1 Li a b i l i t y a n d w a r r a n t y The “ General sales and delivery condit ions” of Brooks Aut om at ion ( Germ any) Gm bH always apply. The warrant y period is 12 m ont hs beginning wit h t he delivery of t he device, which is verified by t he invoice or ot her docum ent s. The warrant y includes repairs of all dam age t o t he device t hat occurs during t he warrant y period and was clearly caused by m at erial or m anufact uring defect s. Liabilit y and warrant y claim s in cases of inj ury t o persons or dam age t o propert y are excluded if t hey can be at t ribut ed t o one or m ore of t he following causes: ■ incorrect use of t he device ■ disregard of t he inform at ion in t he product m anual ■ unaut horized st ruct ural m odificat ions of t he device ■ insufficient m aint enance and repairs ■ disast ers due t o foreign obj ect s or force m aj eure 3 .2 O b j e ct iv e s o f t h e p r o d u ct m a n u a l This product m anual serves as support and cont ains all t he necessary safet y inform at ion t hat m ust be followed for general safet y, t ransport , inst allat ion and operat ion. This product m anual wit h all safet y inform at ion ( as well as all addit ional docum ent s) m ust be: ■ followed, read and underst ood by all persons working wit h t he device ( especially t he safet y inform at ion) ■ easily available t o all persons at all t im es ■ im m ediat ely consult ed in case of t he least doubt ( safet y) Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 12 Ch a p t e r 3 Ge ne r a l I nst r uct ions Obj ect ives: ■ avoid accident s ■ increase t he service life and reliabilit y of t he device ■ reduce cost s due t o product ion downt im es nbb Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 13 Ch a p t e r 4 Sa fe t y I nst r uct ions Sa f e t y I n st r u ct io n s This chapt er gives you an overview of t he following t opics: ■ Area of applicat ion and sym bols ■ Obligat ions ■ ESD inst ruct ions ■ Residual risks ■ Addit ional inform at ion 4 .1 D AN GER Ar e a o f a p p lica t io n a n d sy m b o ls D a n g e r t o l i f e , r i sk o f i n j u r i e s o r d a m a g e t o p r o p e r t y Risks exist when disregarding t he product m anual and t he safet y inst ruct ions t herein. Carefully read t he product m anual before init ial com m issioning. Perform t he required safet y m easures before init ial com m issioning. Follow t he general safet y inform at ion as well as t he special safet y inform at ion given in ot her chapt ers. The device was const ruct ed according t o st at e- of- t he- art t echnology and recognized safet y regulat ions. I n order t o prevent any risks t o life and lim b of t he user, t hird part ies or dam age t o t he device, only use t he device for it s int ended purpose and in perfect condit ion wit h regard t o safet y. Bodily inj uries and/ or propert y dam age result ing from non- com pliance wit h t he inst ruct ions given in t he product m anual are t he responsibilit y of t he com pany operat ing t he device or of t he assigned personnel. Malfunct ions t hat could com prom ise safet y m ust be elim inat ed im m ediat ely. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 14 Ch a p t e r 4 Sa fe t y I nst r uct ions 4 .1 .1 W ARN I N G Sa fe t y sym bols – in com plia n ce w it h 4 8 4 4 - 2 R i sk o f i n j u r i e s w h e n d i sr e g a r d i n g sa f e t y sy m b o l s Risks exist when disregarding warnings in t he product m anual. Please heed t he warnings. Special safet y sym bols in accordance wit h DI N 4844- 2 are used in t he corresponding passages in t he t ext of t his product m anual and require special at t ent ion depending on t he com binat ion of signal word and sym bol. 4 .1 .2 W a r n in g sy m bols nbb W a r n i n g a g a i n st hazardous area W a r n i n g a g a i n st h a z a r d o u s e l e ct r i ca l volt a ge W a r n i n g a g a i n st e l e ct r o m a g n e t i c r a dia t ion W a r n i n g a g a i n st fla m m a b le m a t e r ia ls W a r n i n g a g a i n st p o t e n t i a l l y e x p l o si v e a t m o sp h e r e W a r n i n g a g a i n st e l e ct r o st a t i ca l l y se n si t i v e co m p o n e n t s 4 .1 .3 Pr oh ibit ion sym bols U n a u t h o r i z e d a cce ss is pr oh ibit e d Fi r e , o p e n f l a m e a n d sm o k i n g i s p r o h i b i t e d Sw i t ch i n g i s pr oh ibit e d Pr oh ibit ion Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 15 Ch a p t e r 4 Sa fe t y I nst r uct ions 4 .1 .4 Ot h e r sy m bols D i sp o se o f p a ck i n g m a t e r i a l a cco r d i n g t o r e gu la t ion s R e cy cl i n g I m port ant in for m a t ion Re f e r t o m a n u a l D i sco n n e ct f r o m p o w e r su p p l y Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 16 Ch a p t e r 4 Sa fe t y I nst r uct ions 4 .2 Obligat ions 4 .2 .1 Ope r a t in g com pa n y’s obliga t ion s The safe condit ion and use of t he device is a requirem ent for t he safe operat ion of t he device. The com pany operat ing t he device t herefore has t he obligat ion t o ensure t hat t he following point s are adhered t o: The device m ay only be operat ed by t rained and aut horized personnel! Avoid unsafe and/ or dangerous work procedures! I f necessary, check em ployees' act ions! Only perm it personnel t o be t rained or inst ruct ed wit hin t he scope of a general t raining work on t he device under t he supervision of an experienced person! Personnel m ust have underst ood t he product m anual. Have t his confirm ed by signat ure! Precisely est ablish responsibilit ies according t o t he various t ask areas ( operat ion, inst allat ion) ! Operat ing personnel m ust be com m it t ed t o im m ediat ely report ing t o t heir superior any ident ifiable safet y deficiencies which occur! 4 .2 .2 Ope r a t in g pe r son n e l’s obliga t ion s Operat ors are obligat ed t o cont ribut e t o t he prevent ion of work accident s and t he consequences of t hem by t heir personal conduct . Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 17 Ch a p t e r 4 Sa fe t y I nst r uct ions W ARN I N G R i sk o f i n j u r i e s d u e t o i n su f f i ci e n t p e r so n n e l q u a l i f i ca t i o n s A risk exist s for personnel and t he proper operat ion due t o insufficient ly qualified personnel. Only t rained personnel m ay operat e t he device. New operat ors m ust be inst ruct ed by t he current operat ing personnel. The operat ing com pany m ust precisely regulat e and m onit or t he personnel's areas of responsibilit y and com pet ence. Personnel for t he areas of responsibilit y m ent ioned above m ust have t he corresponding qualificat ion for t his work ( t raining, inst ruct ions) . I f necessary, t his can be done by t he m anufact urer on behalf of t he operat ing com pany. All warrant y claim s are void when disregarded. 4 .3 CAUTI ON ESD i n st r u ct i o n s St at ic elect ricit y can dam age elect ronic com ponent s in t he device. All persons inst alling or m aint aining t he device m ust be t rained in ESD prot ect ion. ESD prot ect ive m easures m ust be applied when opening t he device. Disconnect t he power supply prior t o rem oving or adding com ponent s. Discharge your body and all t ools used prior t o cont act ing any com ponent s on t he int erior of t he device! 4 .4 Touch elect ronically sensit ive part s carefully and at t he corners! Re sid u a l r isk s Even if all precaut ions have been t aken, t here m ay be unapparent residual risks! Adhering t o t he safet y inst ruct ions, t he int ended use, and t he product m anual as a whole can reduce residual risks! Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 18 Ch a p t e r 4 Sa fe t y I nst r uct ions D AN GER R i sk s f r o m e l e ct r i c cu r r e n t Elect rical energy rem ains in lines, equipm ent and devices even when t he device is swit ched off. Only allow qualified elect ricians t o perform work on t he elect rical supply syst em . ATTEN TI ON Disconnect t he device from t he power supply syst em if act ive part s of t he device can be accessed by using t ools. Access is only perm it t ed for aut horized personnel. Regularly check t he elect rical equipm ent of t he device. Regularly check all m oving cables for dam age wit hin t he scope of m aint enance and repairs. D AN GER R i sk o f f i r e a n d e x p l o si o n s Fire and explosions m ay occur wit hin t he vicinit y of t he device. Sm oking, open flam es and fire are st rict ly prohibit ed in t he vicinit y of t he device. Do not st ore any flam m able liquids wit hin t he hazardous area. Keep a fire ext inguisher in t he vicinit y of t he device. W ARN I N G W a r n i n g a g a i n st e l e ct r o m a g n e t i c r a d i a t i o n Elect rom agnet ic radiat ion develops when t ransm it t ing and receiving dat a. Set t he ant enna in such a posit ion t hat it is not in t he vicinit y of or t ouches a hum an body while t ransm it t ing. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 19 Ch a p t e r 4 Sa fe t y I nst r uct ions 4 .5 Addit ion a l in for m a t ion ■ Read and underst and all safet y and product m anuals prior t o inst alling and operat ing t he device. ■ This docum ent at ion was writ t en for specifically t rained personnel. I nst allat ion, operat ion and t roubleshoot ing m ay only be carried out by specifically t rained personnel. ■ Ret ain t hese inst ruct ions. Keep t his docum ent at ion in a locat ion t hat is accessible t o all personnel involved wit h t he inst allat ion, use and t roubleshoot ing of t he device. ■ Follow all warnings. Follow all warnings on and in t he device and in t he docum ent at ion. ■ I nst all t he device only in accordance wit h t he m anufact urer's inst ruct ions. ■ Use only t he accessories and cables from t he m anufact urer. ■ Troubleshoot ing t hat is not described in Chapt er Service and Troubleshoot ing m ay only be perform ed by t he m anufact urer. ■ People wit h hearing aids should be aware t hat t he radio signals em it t ed by t he device can cause annoying noises in t he hearing aid. ■ Do not connect t he device t o power supplies such as norm al household elect rical out let s. The device should only be connect ed t o power supplies as specified in t his docum ent . ■ When rem oving a cable, only pull on t he plug and not on t he cable. Connect cable connect ors st raight and carefully t o avoid dam aging t he cont act s. ■ Never overbend t he ant enna cables or subj ect t hese t o m echanical forces. ■ When replacem ent part s are required, use only t he replacem ent part s t hat were specified by t he m anufact urer. Unaut horized spare part s can result in fire, elect ric shock or ot her hazards. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 20 Ch a p t e r 4 Sa fe t y I nst r uct ions Rule s a n d r e gula t ions The provisions of t he accident prevent ion regulat ions of t he governm ent safet y organizat ions always apply t o all work on t he device. The following m ust also be observed: ■ applicable legally binding accident- prevent ion regulat ions ■ applicable binding regulat ions at t he place of use ■ t he recognized t echnical rules for safe and professional work ■ exist ing environm ent al prot ect ion regulat ions ■ ot her applicable regulat ions Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 21 Ch a p t e r 5 Pr oduct Spe cifica t ion s Pr o d u ct Sp e cif ica t io n s This chapt er gives you an overview of t he following t opics: ■ Funct ion ■ I m ages ■ Descript ion of t he com ponent s ■ Technical dat a 5 .1 Fu n ct io n The Brooks RFI D UF70 Cert um reader is a m ult iprot ocol reader for reading passive t ransponders in t he frequency range of 865 MHz t o 868 MHz for Europe and 902 MHz - 928 MHz for t he FCC. The device operat es at 2 W and 1 W HF power at t he ant enna j ack depending on t he regist rat ion area. When delivered, t he device can read and writ e t ransponders according t o t he EPC Gen2 st andard. Ot her prot ocols can be added via soft ware updat es. The device has several high perform ance int erfaces for com m unicat ions. The reader has four ant enna port s for t he connect ion of t ransm it t ing and receiving ant ennas for com m unicat ing wit h RFI D t ransponders. The device also has various int erfaces for t he connect ion wit h t he PC, depending on t he configurat ion st age. Power is supplied via a 3- pin M8 connect or. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 22 Ch a p t e r 5 Pr oduct Spe cifica t ion s 5 .2 I m ages 5 .2 .1 Fr on t vie w nbb Power ( 24 V) RS232 int erface Et hernet int erface 4 ant enna port s Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 23 Ch a p t e r 5 Pr oduct Spe cifica t ion s 5 .2 .2 Re a r vie w 4 I / Os Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 24 Ch a p t e r 5 Pr oduct Spe cifica t ion s 5 .2 .3 Top vie w Ant enna port LED Mode LED Test Error LED Mode but t on Test OK LED Reset but t on Test but t on Power LED Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 25 Ch a p t e r 5 Pr oduct Spe cifica t ion s 5 .3 D e scr ip t io n o f t h e co m p o n e n t s Co m p o n e n t s Power LED D e scr i p t i o n I f t he correct volt age is applied t o t he device, t he Power LED is green and t he device is operat ional. Reset but t on Pressing t his but t on init iat es a power- reset of t he device. The reset but t on m ust be pressed for at least t hree seconds unt il all t he LEDs of t he foil keypad sim ult aneously st art and t he hardware reset is execut ed. Mode but t on I f t he m ode but t on and t he reset but t on are sim ult aneously pressed at a powerup reset for about 15 seconds unt il all t he LEDs of t he keypad light up for t he second t im e, t he reader will be reset t o t he default st at e ( default fact ory set t ing) . Mode LED Current ly no use. Test but t on Pressing t his but t on swit ches t he device t o t he reading t est m ode and is used t o select t he ant enna port s. I f t he but t on is pressed for a longer t im e ( at least 2 seconds) , t hen t he t est m ode is act ivat ed ( Test OK LED and Test Error LED bot h briefly com e on) or disabled ( Test OK LED and Test Error LED bot h go out ) . Briefly pressing t he but t ons when t he t est m ode is act ivat ed result s in swit ching t o t he next ant enna port . Test OK LED When a t ransponder in t he t est m ode can be successfully ident ified, t his LED t urns green. Test Error LED When a t ransponder in t he t est m ode cannot be successfully ident ified, t his LED t urns red. Ant enna port LED 1 These LEDs signal t he dat a t raffic t o t he respect ive to 4 ant enna port s. Once dat a is read or writ t en via t he ant enna port 1 ( above) , t he ant enna port LED 1 ( above) t urns green. Ant enna port s Port s t o connect t he ant ennas. I / O port s 1 t o 4 A digit al input and out put can be connect ed t o each ant enna port . A 3 wire sensor or dry cont act is possible as t he input . The out put can operat e a LED wit hout a series resist or or direct ly swit ch 5 V DC ( I m ax = 100 m A) . Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 26 Ch a p t e r 5 Pr oduct Spe cifica t ion s Co m p o n e n t s RS232 int erface D e scr i p t i o n Com m unicat ions wit h t he device can be m ade via t he serial int erface ( 9 pin sub- D socket ) . Baudrat es of 1,200 Bd up t o 57,600 Bd are possible. Et hernet int erface Com m unicat ions wit h t he device can be m ade via t he 10/ 100 BaseT int erface. Volt age supply Cont act for connect ing t he 24 V DC volt age supply connect ion Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 27 Ch a p t e r 5 Pr oduct Spe cifica t ion s 5 .4 Te ch n ica l d a t a T e ch n i ca l d a t a Volt age 24 V DC ± 10% Power consum pt ion approx. 0.8 A at 24 V Operat ing t em perat ure - 20 t o 50 ° C - 4 ° F t o 122 ° F St orage t em perat ure - 40 t o 85 ° C - 40 ° F t o 185 ° F Perm issible hum idit y at 50 ° C / 122 ° F 25 – 85% Prot ect ion class I P 40 ( opt ional I P 65) Housing m at erial Passivat ed alum inum Weight approx. 1,500 g Air int erface I SO 18000- 6C ( EPC Global Class 1 Gen2) Frequency range Europe 865 – 868 MHz Frequency range FCC 902 – 928 MHz Radiat ion power < 2 Wat t ERP Transm it t ing power program m able in 1 dB st eps Read / writ e range up t o 8 m Serial int erface RS232 1,200 Bd – 57,600 Bd Et hernet int erface 10/ 100 BaseT Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 28 Ch a p t e r 5 Pr oduct Spe cifica t ion s D e vice la be l The device label wit h t he CE m ark, part / serial num ber and MAC address is on t he device housing. Part num ber Serial num ber MAC address Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 29 Ch a p t e r 6 I nst a lla t ion I n st a lla t ion This chapt er gives you an overview of t he following t opics: ■ Safet y inst ruct ions ■ Qualified inst allat ion personnel ■ Unpacking ■ Assem bly of t he device ■ Ant enna inst allat ion ■ Power supply ■ Term inal connect ion ■ Ext ernal input and out put ( opt ional) ■ Com m issioning Re f e r t o m a n u a l Follow t he general safet y inst ruct ions in t he chapt er Safet y I nst ruct ions. 6 .1 CAUTI ON Sa f e t y in st r u ct io n s The device is exclusively designed for indoor use in an indust rial environm ent . I nst allat ion is only allowed in an int erior room at a const ant t em perat ure bet ween - 20 ° C / - 4 ° F and + 50 ° C / 122 ° F, and a relat ive hum idit y bet ween 25% and 80% . Never use t he device near or in wat er. Never pour liquids of any t ype over t he device. I f t he device should accident ally com e in cont act wit h liquid, disconnect it and have it checked by a t echnician. Do not inst all t he device near heat sources such as radiat ors, heat regist ers, st oves or ot her devices ( including am plifiers) t hat generat e heat . Do not inst all t he device in a flam m able environm ent . Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 30 Ch a p t e r 6 I nst a lla t ion CAUTI ON Never expose t he device t o ext rem e t em perat ure fluct uat ions, since ot herwise condensat ion develops in t he device and causes dam age. Do not inst all t he device in t he vicinit y of volt age lines or ot her power lines wit h which t hey could collide ( for exam ple, drilling) , which could result in serious inj uries or even deat h. The device ( especially t he ant enna) should not be inst alled in t he im m ediat e vicinit y of elect rical equipm ent such as m edical devices, m onit ors, t elephones, TV set s, m agnet ic disks and m et al obj ect s. nbb This could result in reduced read and writ e ranges. Never use t he device in explosive areas ( e.g. paint warehouses) . CAUTI ON ATTEN TI ON Do not use t he device in areas where it is exposed t o vibrat ions or shocks. The inst allat ion locat ion m ust be adequat ely illum inat ed during t he inst allat ion. Never inst all t he device during a light ning st orm . Verify t hat t he inst allat ion m eet s t he requirem ent s of t he ( count ry- specific) FCC for hum an exposure t o radio frequencies. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 31 Ch a p t e r 6 I nst a lla t ion ATTEN TI ON When det erm ining t he inst allat ion sit e, keep in m ind t he lengt h of t he ant enna wire and t he read/ writ e range of t he ant enna used. 6 .2 Qu a lif ie d in st a lla t io n p e r so n n e l CAUTI ON The inst allat ion is t o be carried out by specially t rained personnel only. I f you are uncert ain about t heir qualificat ion, cont act t he m anufact urer. CAUTI ON I nst alling t he device wit hout special t raining can result in dam age t o t he reader and/ or connect ed devices. 6 .3 U n p a ck in g The device and t he accessories are packed under clean- room condit ions. I n order t o m aint ain t his condit ion, t he device m ust also be unpacked in clean- room condit ions. D isposin g of t h e pa ck a ging m a t e r ia l The packaging m at erial consist s of cardboard and foil. Dispose of t hese m at erials separat ely and under t he respect ive legal regulat ions of your count ry. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 32 Ch a p t e r 6 I nst a lla t ion 6 .4 ATTEN TI ON Asse m b ly o f t h e d e v ice The m ount ing surface m ust be st able, non- flam m able, dry and clean. I f necessary, clean it before you inst all t he device. The device m ust be inst alled so t hat air can freely circulat e vert ically t hrough t he heat sink, and t he operat ing and environm ent al condit ions specified under Technical dat a are m et at all t im es. I nst a lla t ion dim e n sion s Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 33 Ch a p t e r 6 I nst a lla t ion 6 .5 ATTEN TI ON An t e n n a in st a lla t ion Consider t he required read and writ e ranges when inst alling t he ant enna. The reader can only be used properly if t he t ransponder is locat ed wit hin t he individual reading/ writ ing range of t he respect ive ant enna. I f t he t ransponder is very close t o t he ant enna, t he t ransponder m ay be det uned by t he m et al of t he ant enna and a reading/ writ ing is not possible. We recom m end keeping a m inim um dist ance bet ween t ransponder and ant enna of about 10 m m . 6 .5 .1 Posit ion in g t h e a nt e n n a Reliable reading and writ ing depends on t he dist ance and orient at ion of t he t ransponder from t he ant enna. Depending on t he polarizat ion of t he ant enna and t he design of t he t ransponder, t he orient at ion of t he t wo t oget her should be considered when a reliable ident ificat ion m ust be guarant eed. More inform at ion on applicat ion- specific ant enna st ruct ures can be obt ained from our support t eam . 6 .5 .2 Av a ila ble a n t e n n a t ype s Different t ypes of ant ennas are available on request . 6 .6 D AN GER Pow e r su p p ly R i sk o f d e a t h f r o m d a n g e r o u s v o l t a g e Risks exist when supplying t he device wit h t he incorrect volt age. Only use cables, plugs and adapt ers supplied by t he m anufact urer. Observe power rat ings of t he t echnical dat a ( Technical dat a) . The device can be connect ed t o an int ernal power supply of t he syst em or t o an ext ernal power supply. Once t he device is connect ed t o t he power supply, t he power LED light s up. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 34 Ch a p t e r 6 I nst a lla t ion I f t he LED does not light up, please refer t o chapt er Error display wit h LED. Pin Si g n a l GND + 24 V DC GND 6 .7 Pins 1 and 3 are bot h grounded. Te r m in a l co n n e ct io n The serial int erface is a Sub- D socket ( 9- pin) . A norm al RS232 ext ension cable can be used. Pin D B9 NC TxD RxD NC GND NC NC NC NC Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 35 Ch a p t e r 6 I nst a lla t ion 6 .8 Ex t e r n a l i n p u t a n d o u t p u t ( o p t i o n a l ) The following I / O versions are possible: A digit al input and out put can be connect ed t o each ant enna port . A 3 wire sensor or dry cont act is possible as t he input . The out put can operat e a LED wit hout a series resist or or direct ly swit ch 5 V DC. 6 .9 Co m m i s s i o n i n g 6 .9 .1 Re qu ir e d ope r a t in g con dit ion s The following t wo condit ions m ust be fulfilled for operat ing t he device: An ant enna m ust be connect ed correct ly t o t he reader. Connect t he power supply and swit ch on t he device ( if a POE is not used) . The t ransponder m ust be locat ed wit hin t he individual reading/ writ ing range of t he ant enna ( for t est ing) ! 6 .9 .2 Pa r a m e t e r s of t h e se r ia l in t e r fa ce Baudrat e 57,600 Dat a bit s St op bit Parit y No Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 36 Ch a p t e r 6 I nst a lla t ion 6 .9 .3 Pa r a m e t e r s of t h e Et h e r n e t in t e r fa ce The Et hernet is connect ed via an Et hernet m odule. Tools are available t hat allow t he Et hernet set t ings t o be configured. By using Discovery Tools, all Et hernet devices locat ed in t he net work can be found. The respect ive device can be configured via a web server and a web browser via a double click. I f t he TCP / I P address is known, t he web server can also be direct ly opened in a browser also follows: ht t p: / / xxx.xxx.xxx.xxx/ U se r : " r o o t " P a ssw o r d : " d b p s" xxx.xxx.xxx.xxx – current ly set I P address Login The I P address can be set via t he " net work" link. The set t ings are t ransferred wit h t he " apply" but t on and t he device is t hen reboot ed. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 37 Ch a p t e r 6 I nst a lla t ion Con figu r a t ion I M PORTAN T The " Fact ory Default Set t ings" m ust not be set under any circum st ances as t hey are not t he fact ory set t ings of Brooks. Any ot her set t ings of t he Et hernet device ( exept t he I P address) m ust not be changed. Ot herwise a fault- free com m unicat ion cannot be guarant eed by Brooks. D igi D e vice D iscove r y The t ool displays all devices t hat have a Digi Connect ME. Devices t hat are not in t he sam e subnet are also displayed. The I P address can be set direct ly via " configure net work set t ings" . Fixed I Ps or DHCPs are possible. The web server of t he device can be accessed direct ly via t he " open web int erface" . Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 38 Ch a p t e r 6 I nst a lla t ion Se le ct ion w indow I n pu t w in dow Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 39 Ch a p t e r 7 Operation Opera t ion This chapt er gives you an overview of t he following t opics: ■ Operat ing personnel ■ Com m unicat ion prot ocol ASC- I 1 ■ Addit ional inform at ion 7 .1 CAUTI ON Op e r a t in g p e r son n e l The UF70 Cert um reader should only be operat ed by specially t rained personnel. I f you have doubt s about t he required qualificat ions, cont act t he m anufact urer. Operat ing t he device wit hout special t raining can result in dam age t o t he reader and/ or connect ed devices. 7 .2 Co m m u n i ca t i o n p r o t o co l A S C- I 1 7 .2 .1 St r u ct u r e of t h e com m u n ica t ion pr ot ocol General rem arks: ■ The com m unicat ion is done wit h ASCI I packages. ■ Each device has an RS232 int erface and an opt ional Et hernet int erface t o which an address from 0 t o E can be assigned. The device has a default address of 0 on delivery. ■ Aft er each com m and t o t he device, a defined response is sent . We recom m end wait ing for t his response before sending a new com m and. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 40 Ch a p t e r 7 Operation 7 .2 .2 Pa ck a ge con t e n t s General rem arks: Each package includes a package header ( t hree charact ers) , a m essage ( t wo or m ore charact ers) and t he end of t he package ( five charact ers) . P a ck a g e h e a d e r Pa ck a ge he a de r M e ssa g e En d o f p a ck a g e The header includes t he st art charact er ( one charact er) and t he package lengt h ( t wo charact ers) 2 st art ing charact ers and 4 lengt h byt es are sent in t he ext ended ASCI I prot ocol. nbb P a ck a g e h e a d e r St art Lengt h 1 Lengt h 2 St art St art charact er ( ASCI I charact er ´ S´ ) Lengt h 1 High byt e package lengt h ( hexadecim al) – ASCI I charact ers ´ 0´ ..´ F´ Lengt h 2 Low byt e package lengt h ( hexadecim al) – ASCI I charact ers ´ 0´ ..´ F´ Ext ended ASCI I form at : P a ck a g e h e a d e r St art 1 St art 1 St art 2 St art 2 Lengt h 1 Lengt h 2 Lengt h 3 Lengt h 4 First st art charact er ( ASCI I charact er 'S') Second st art charact er ( ASCI I charact er 'X') for m arking t he ext ended ASCI I prot ocol Lengt h 1 High byt e package lengt h ( hexadecim al) ASCI I charact ers ´ 0´ ..´ F´ Lengt h 2 Byt e package lengt h ( hexadecim al) ASCI I charact ers ´ 0´ ..´ F´ Lengt h 3 Byt e package lengt h ( hexadecim al) ASCI I charact ers ´ 0´ ..´ F´ Lengt h 4 Low byt e package lengt h ( hexadecim al) - ASCI I charact ers ´ 0´ ..´ F´ The m essage lengt h describes t he num ber of charact ers of a m essage. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 41 Ch a p t e r 7 Operation M e ssa ge st r uct ur e The m essage cont ains a com m and, a t arget and source address, t he num ber of t he ant enna port ( Head) and t he act ual inform at ion. The num ber of t he ant enna port is not required for all m essages. M e ssa g e Com m and Address Head I nform at ion Com m and ASCI I charact ers ( see sect ion Com m ands of prot ocol) Address Target or source address; ASCI I charact ers '0'...’E’ * ) Head Opt ional – for m essages t hat refer t o a specific ant enna port I nform at ion Depends on t he com m and ( includes none, one or m ore ASCI I charact ers '0'...'F') * ) The device is pre- configured wit h an address of '0' on delivery. End of pa ck a ge The end of t he package includes an end ( 1 charact er) and t he checksum ( 4 charact ers) En d o f p a ck a g e End Checksum Checksum Checksum Checksum End End charact er ASCI I charact er no. 13 ( hexadecim al 0D) Checksum 1 High- byt e – XOR logic for all dat a ( package header, m essage and end charact er) ; ASCI I ‘0’..’F’ Checksum 2 Low byt e – XOR logic for all dat a ( package header, m essage and end charact er) ; ASCI I ‘0’..’F’ Checksum 3 High byt e – addit ion of all dat a ( package header, m essage and end charact er) ; ASCI I ‘0’..’F’ Checksum 4 Low byt e – addit ion of all dat a ( package header, m essage and end charact er) ; ASCI I ‘0’..’F’ Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 42 Ch a p t e r 7 Operation ATTEN TI ON When using t he TCP/ I P int erface opt ion, t he checksum is not used ( is not t ransm it t ed) . 7 .2 .3 Com m a n ds of pr ot ocol Com m a n ds Co m m a n d D e scr i p t i o n X or URX Read dat a range of all EPC t ransponders URY Read dat a range of t he EPC t ransponders wit h special EPC code EPC scanning URB EPC bulk reading wit h t im e specificat ion Writ e EPC of a single t ransponder UWW Writ e dat a range of all EPC t ransponders UWZ Writ e dat a range of t he EPC t ransponders wit h special EPC code UMW Writ e dat a range m asked of all EPC t ransponders UMZ Writ e dat a range m asked of t he EPC t ransponders wit h special EPC code UBW Erase block of all EPC t ransponders UBZ Erase block of t he EPC t ransponders wit h special EPC code ULW Ret rieving all EPC t ransponders ULZ Ret rieving all EPC t ransponders wit h special EPC code UKW Killing all EPC t ransponders UKZ Killing all EPC t ransponders wit h special EPC code T or UAM Act ivat e polling: EPC scanning UAA Act ivat e polling: Read raw UAX Act ivat e polling: Read dat a range UAW Act ivat e polling: Writ e dat a range Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 43 Ch a p t e r 7 Operation Co m m a n d D e scr i p t i o n UAZ Act ivat e polling: Writ e dat a range m asked UAB Act ivat e polling: Erase block of all EPC t ransponders UAL Act ivat e polling: Ret rieving all EPC t ransponders UAK Act ivat e polling: Killing all EPC t ransponders UAR Read t ransponder rat e in t he polling operat ion UAE St op polling UCX Act ivat e polling: NXP- UCODE- G2X Read Prot ect UCN Act ivat e polling: NXP- UCODE- G2X Reset Read Prot ect UCC Act ivat e polling: NXP- UCODE- G2X Change EAS UCE Act ivat e polling: NXP- UCODE- G2X EAS Alarm UFW Set filt er dat a UFR Read filt er dat a UFP Set filt er UFG Read filt er st at us UGL Read out list of radio profiles UGP Det erm ine act ive radio profile UPP Set t he act ive radio profile UNH Perform hardware reset N or UNR Perform soft ware reset UPE Load fact ory default values Request param et er Set param et er UGK Read t he num ber of t he act ive param et er set UPK Set t he num ber of t he act ive param et er set UGD Read t he num ber of t he default param et er set UPD Set t he num ber of t he default param et er set Sensor st at us Set t ing t he out put s Queries of out put s ( st at us) Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 44 Ch a p t e r 7 Operation Co m m a n d D e scr i p t i o n Error m essage Heart beat ( request serial num ber) V or UVR Request soft ware version UGT Read UTC t im e UPT Set UTC t im e Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 45 Ch a p t e r 7 Operation M e ssa ge it e m s Acce ss w o r d 8 bytes The 4 byt e access word is required t o access t he various m em ory areas of t he EPC t ransponder. The LSB byt e is t ransm it t ed first during t he t ransm ission. The dat a are int erpret ed in HEX form at . That is, t wo ASCI I charact ers in t he m essage equal one byt e of dat a in HEX form at . Exam ple: 0x01020304 ASCI I st ring: " 04030201" Bu l k t i m e 4 bytes 2 byt es t im e in m illiseconds specifying how long t o read. The LSB byt e is t ransm it t ed first during t he t ransm ission. The dat a are int erpret ed in HEX form at . That is, t wo ASCI I charact ers in t he m essage equal one byt e of dat a in HEX form at . Exam ple: 0x0064 ( 100 m s) ASCI I st ring " 6400" CM D 1 - 3 bytes Com m and of t he m essage. See t able in chapt er Com m ands of prot ocol. Dat a w ords 2 to N* 4 bytes Dat a words ( 2 byt es) are always read or writ t en. The dat a are int erpret ed in HEX form at . That is, t wo ASCI I charact ers in t he m essage describe one byt e of t ransponder dat a in HEX form at . Exam ple: HEX t ransponder dat a: ASCI I t ransm ission: Transm it t ed ASCI I st ring: Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 0x12, 0x34, 0x56, 0x78 ( 2 dat a words) 0x31, 0x32, 0x33, 0x34, 0x35, 0x36, 0x37, 0x38 " 12345678" 46 Ch a p t e r 7 Operation D H CP 1 byte A net work configurat ion t hat det erm ines if t he st at ic net work address is being used or if t he DHCP server assigns t he net work address. " 0" DHCP is not act ive, use st at ic net work address " 1" DHCP is act ive; obt ain net work address from t he DHCP server D i r e ct i o n 2 bytes When polling, t he direct ion flag shows if a t ransponder ent ers or leaves t he field. The display t hat a t ransponder leaves t he field can be act ivat ed via param et er 0x29. The dat a are int erpret ed in HEX form at . That is, t wo ASCI I charact ers in t he m essage equal one byt e of dat a in HEX form at . Values: " 00" ( 0x00) The t ransponder leaves t he field " 80" ( 0x80) The RSSI value changed The t ransponder m oved wit hin t he field " FF" ( 0xFF) The t ransponder ent ers t he field EP C ( 2 n+ 1 ) * 2 bytes Wit h t he UHFI 20 soft ware version ( firm ware 2.x) , t he EPC code has a flexible lengt h n from 0 t o 31 dat a words ( 2 byt es dat a) . An n byt e is placed before t he act ual EPC code and corresponds t o t he quant it y of EPC dat a words. The EPC code is t ransferred so t hat t he LSB byt e is t ransm it t ed first . The dat a are int erpret ed in HEX form at . That is, t wo ASCI I charact ers in t he m essage equal one byt e of dat a in HEX form at . The following applies t o t he num ber of EPC dat a words: 0< = n< = 31 Exam ple: ASCI I st ring: " 060C0B0A090807060504030201" Num ber of EPC dat a words: 0x06 EPC: 0x0102030405060708090A0B0C Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 47 Ch a p t e r 7 Operation Ex f l a g 2 bytes The ext ension flag det erm ines which inform at ion is included in t he recognized EPC t ransponder. The Ex flag is set by param et er 0x76. The dat a are int erpret ed in HEX form at . That is, t wo ASCI I charact ers in t he m essage equal one byt e of dat a in HEX form at . Values: 0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x09 0x0A 0x0B 0x0C 0x0D 0x0E 0x0F do not t ransm it ext ensions only t ransm it ant enna port only t ransm it RSSI value t ransm it ant enna port and RSSI t ransm it t im e st am p t ransm it t im e st am p and ant enna port t ransm it t im e st am p and RSSI value t ransm it t im e st am p, RSSI value and ant enna port t ransm it t ransponder prot ocol cont rol word t ransm it ant enna port and t ransponder prot ocol cont rol word t ransm it RSSI value and prot ocol cont rol word t ransm it ant enna port , RSSI value and prot ocol cont rol word t ransm it t im e st am p and prot ocol cont rol word t ransm it t im e st am p, ant enna port and prot ocol cont rol word t ransm it t im e st am p, RSSI and prot ocol cont rol word t ransm it t im e st am p, RSSI , ant enna port and prot ocol cont rol word Ex t e n si o n 0 - 1 2 bytes I f and which ext ensions are t ransm it t ed for each det ect ed EPC t ransponder is defined by t he Ex flag. The dat a are int erpret ed in HEX form at . That is, t wo ASCI I charact ers in t he m essage equal one byt e of dat a in HEX form at . The act ivat ed ext ensions are t ransferred in t he following order: 2 ASCI I charact ers ant enna port 2 ASCI I charact ers RSSI value 8 ASCI I charact ers UTC t im e st am p ( LSB byt e is t ransm it t ed first ) 4 or 8 ASCI I charact er prot ocol word as applicable including XPC_W1 and XPC_W2 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 48 Ch a p t e r 7 Operation Fi l t e r m a sk N* 2 bytes The filt er bit s required for t he developm ent of a filt er are defined in HEX form at in a filt er m ask. That is, t wo ASCI I charact ers in t he m essage equal one byt e of dat a in HEX form at . The LSB byt e of t he filt er m ask is t ransm it t ed first . Exam ple: N= 3 Num ber of m ask bit s: 18 Filt er m ask: " 0x03FEFE" Transm ission: " FEFE03" Fi l t e r n u m b e r 2 bytes The filt ers defined for filt ering are num bered consecut ively from 0 t o 31. Values: " 00" – Filt er 0 … "1F" – Filt er 31 Fr a m e I D 2 bytes The response of t he reader can be accom plished in several fram es ( e.g. if m any t ransponders were scanned) . The fram e I D t hat is sent indicat es how m any response m essages follow. Short responses t hat consist only of a single fram e t hen always have t he fram e I D " 00" . Messages consist ing of m ult iple fram es should be fully received and assem bled by t he host before t hey are processed. The dat a are int erpret ed in HEX form at . That is, t wo ASCI I charact ers in t he m essage equal one byt e of dat a in HEX form at . Head I D 1 byte Num ber of t he ant enna port ( 0 – 4) . "0" read on all ant enna port s "1"- " 4" single ant enna port Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 49 Ch a p t e r 7 Operation M a sk N* 4 bytes The bit- orient ed m ask det erm ines what dat a will act ually be overwrit t en in t he m asked writ e. The m ask has t he sam e lengt h as t he dat a t o be writ t en and act ual dat a is only writ t en in t he places where a 1 is locat ed in t he m ask. The m ask is passed in t he sam e order and lengt h as t he m asked dat a t o be writ t en. Exam ple: N= 1 describe a dat a word m asked Transponder cont ent : New dat a: Mask: new t ransponder cont ent : 0x5678 0x1234 0x0F0F 0x5274 M e m o r y a d d r e ss 8 bytes The m em ory areas of t he EPC t ransponder are addressed by 4 byt e word point ers. The LSB byt e is t ransm it t ed first during t he t ransm ission. The dat a are int erpret ed in HEX form at . That is, t wo ASCI I charact ers in t he m essage equal one byt e of dat a in HEX form at . The exact m em ory dist ribut ion can be derived from t he EPC Global st andard. Mem ory bank 2 bytes The EPC t ransponder has m ult iple m em ory banks, which are addressed by num ber. The exact m em ory st ruct ure can be derived from t he EPC Global st andard chapt er. The dat a are int erpret ed in HEX form at . That is, t wo ASCI I charact ers in t he m essage equal one byt e of dat a in HEX form at . Values: " 00" " 01" " 02" " 03" ( 0x00) ( 0x01) ( 0x02) ( 0x03) Reserved EPC TI D User N um ber of dat a w ords 2 bytes The num ber of dat a words ( 1 dat a word consist s of 2 byt es) , which are read and writ t en, are hereby defined. The dat a are int erpret ed in HEX form at . That is, t wo ASCI I charact ers in t he m essage equal one byt e of dat a in HEX form at . Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 50 Ch a p t e r 7 Operation On/ Off 4 bytes The use of a defined filt er can hereby be enabled or disabled. Values: " 00" – Filt er off " FF" – Filt er on O u t p u t st a t e 1 - 4 bytes Displays t he current st at us of t he out put s at t he corresponding ant enna port ( Head I D) . The inform at ion unit " Out put st at e" includes t he st at us of each out put of an ant enna port . I n t he case of querying t he st at us of all out put s of t he reader, t he "Out put St at e" cont ains t he st at us of all 4 out put s ( 1 per head) . The st at us is represent ed as 1 byt e for each head. Values: – – – – Out put OFF Out put ON Out put flashes unchanged ( query only! ) Pa r a m e t e r n o. 2 bytes Num ber of t he param et er. Two ASCI I charact ers ( 2 byt es) display t he param et er num ber in HEX form at . Exam ple: Param et er 20 0x14 " 14" Pa r a m e t e r va lu e 2 bytes Value of t he param et er. Two ASCI I charact ers ( 2 byt es) specify t he value of t he param et er in HEX form at . Exam ple: Value 192 0xC0 " C0" Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 51 Ch a p t e r 7 Operation Pa yloa d 6 bytes I f a t ransponder m ust be locked, t he area of t he t ransponder t o be locked can be specified by t he payload. The LSB byt e is t ransm it t ed first during t he t ransm ission. Dat a ( 3 byt es) are in HEX form at . That is, t wo ASCI I charact ers in t he m essage equal one byt e of dat a in HEX form at . The exact st ruct ure can be derived from t he EPC Global st andard chapt er " Lock" . Exam ple: Access area wit h Perm alock= 1 lock Payload 0x0300C0 Transfer Prot ocol " C00003" Pr ofile n u m be r 2 bytes Radio profiles realized in t he reader, which are num bered from 0 t o 4. Radio profiles: " 00" " 01" " 02" " 03" " 04" – – – – – Tx: 40kbps/ Rx: 80kbps/ FM0 Tx: 40kbps/ Rx: 40kbps/ Miller2 Tx: 40kbps/ Rx: 160kbps/ FM0 Tx: 40kbps/ Rx: 80kbps/ Miller2 Tx: 40kbps/ Rx: 40kbps/ Miller4 ( default set t ing) Re a de r I D 1 byte Address of t he device ( " 0" .. " E" ) . The default address of t he card is " 0" on delivery. R ECO M M I SSI O N 2 bytes I f a t ransponder m ust be m ade unreadable ( or possibly also recom m issioned) , 3 so- called recom m ission bit s m ust be t ransferred. The value and significance of t he recom m ission bit s depend on t he t ype of t ransponder. The 3 bit s are int erpret ed as one byt e dat a in HEX form at . That is, t wo ASCI I charact ers in t he m essage equal one byt e of dat a in HEX form at . The precise significance of t he 3 recom m ission bit s can be seen in t he docum ent at ion of t he EPC t ransponder and t he EPC global st andard chapt er " Kill" . Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 52 Ch a p t e r 7 Operation R e sp o n se co d e 4 bytes This feat ure is not used for t he single reader. This code is always " 0000" . R e su l t 2 bytes The result flag delivers inform at ion on whet her an act ion was com plet ed successfully. The dat a are int erpret ed in HEX form at . That is, t wo ASCI I charact ers in t he m essage equal one byt e of dat a in HEX form at . Values: "00" ( 0x00) > 0x00 no errors occurred an error occurred Se n so r st a t e 1 byte Displays t he current st at us of t he sensor at t he corresponding ant enna port ( Head I D) . Value 0 Sensor is uncovered ( open) Value 1 Sensor is covered ( closed) Se r i a l n u m b e r 4 bytes Cont ains t he 4- byt e serial num ber of t he reader. The serial num ber is also shown on t he label of t he reader. So f t w a r e v e r si o n 6 - 8 bytes Charact er st ring wit h t he soft ware version of t he reader. The display is in HEX form at . This m eans t hat t he 12- 16 charact ers of t he ASCI I charact er st ring describe t he 6- 8 byt es of t he soft ware version in HEX form at . Exam ple: v0554846493230 0x55 0x48 0x46 0x49 0x32 0x30 = " UHFI 20" Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 53 Ch a p t e r 7 Operation T r a n sp o n d e r e r r o r co d e 2 bytes The t ransponder it self also delivers an error code, which is also t ransm it t ed. The dat a are int erpret ed in HEX form at . That is, t wo ASCI I charact ers in t he m essage equal one byt e of dat a in HEX form at . Values: "00" ( 0x00) > 0x00 no errors occurred an error occurred UTC 8 bytes The Unix t im e code ( UTC) describes t he seconds t hat have passed since 1.1.1970 0: 00: 00. The Unix t im e code ( UTC) is t he sam e worldwide for a specific t im e. The 4 byt es of UTC are t ransm it t ed in hex form at as 2 ASCI I charact ers per byt e. The LSB byt e is t ransm it t ed first . Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 54 Ch a p t e r 7 Operation X or URX - Re a d da t a a r e a The X com m and st art s t he reading of a defined dat a range of t he current EPC t ransponder. Several EPC t ransponders can be locat ed in t he reading area of t he ant enna when using t his com m and. H o st r e a d e r CM D Re a d e r I D Head I D A cce ss w o r d M em ory bank M em ory a d d r e ss N um ber of da t a w ords 1 byt e 1 byt e 8 byt es 2 byt es 8 byt es 2 byt es URX R e a d e r h o st O v e r h e a d r e sp o n se t e l e g r a m 2 ) CM D Re a de r ID Fr a m e ID R e su l t 3 ) 1 byt e 2 byt es 2 byt es urx D a t a o f t h e p a r t i ci p a t i n g EP C t r a n sp o n d e r s 1 ) 2 ) Ex fla g3 ) 2 byt es Ex t e n si o n s EP C 0- 12 byt es ( 2n+ 1) * 2 byt es T r a n sponder error co d e Num ber N data w ords 2 byt es 2 byt es Data w ords N* 4 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. 2) The response of t he t ransponder is opt ional and only appears at result " 00" . 3) The result and Ex flag is only available in t he first t ransm it t ed m essage in m essages wit h several fram es. Exam ple: Read access password ( no t ransponder is present ) > > X0100000000000200000002 < < x0000A Result " 0A" no EPC t ransponder is present Exam ple: Read access password ( 2 t ransponders) > > X0100000000000200000002 < < x0000001 0106010203040506070808080909000200000000 01060B0C090A0708050603040102000200000000 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 55 Ch a p t e r 7 Operation Exam ple: Read access password ( m any t ransponders) > > X0100000000000200000002 < < x0020001 0106480000000000000000000000000200000000 0106010000000000000000000000000200000000 0106060000000000000000000000000200000000 0106270000000000000000000000000200000000 < < x001 0106190000000000000000000000000200000000 0106500000000000000000000000000200000000 0106470000000000000000000000000200000000 0106170000000000000000000000000200000000 0106090000000000000000000000000200000000 0106100000000000000000000000000200000000 0106310000000000000000000000000200000000 0106390000000000000000000000000200000000 0106020000000000000000000000000200000000 0106460000000000000000000000000200000000 0106410000000000000000000000000200000000 0106070000000000000000000000000200000000 01062300000000000000 < < x000 00000000000200000000 0106380000000000000000000000000200000000 0106400000000000000000000000000200000000 0106180000000000000000000000000200000000 0106280000000000000000000000000200000000 0106420000000000000000000000000200000000 0106240000000000000000000000000200000000 0106290000000000000000000000000200000000 0106080000000000000000000000000200000000 0106110000000000000000000000000200000000 0106160000000000000000000000000200000000 0106260000000000000000000000000200000000 0106490000000000000000000000000200000000 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 56 Ch a p t e r 7 Operation URY – Re a d da t a a r e a ( de fine d EPC code ) The URY com m and st art s t he reading of a defined dat a range of t he current EPC t ransponders which have a defined EPC code. Several EPC t ransponders can be locat ed in t he reading area of t he ant enna when using t his com m and. H o st r e a d e r CM D Re a d e r ID Head ID EP C A cce ss w ord Mem ory bank M em ory a d d r e ss Num ber of dat a w ords URY 1 byt e 1 byt e ( 2n+ 1) * 2 byt es 8 byt es 2 byt es 8 byt es 2 byt es R e a d e r h o st O v e r h e a d r e sp o n se t e l e g r a m 2 ) CM D Re a de r ID Fr a m e ID R e su l t 3 ) ury 1 byt e 2 byt es 2 byt es D a t a o f t h e p a r t i ci p a t i n g EP C t r a n sp o n d e r s 1 ) 2 ) Ex fla g3 ) 2 byt es Ex t e n si o n s EP C 0- 12 byt es ( 2n+ 1) * 2 byt es T r a n sponder error co d e N um ber N dat a w ords 2 byt es 2 byt es Data w ords N* 4 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. 2) The response of t he t ransponder is opt ional and only appears at result " 00" . 3) The result and Ex flag is only available in t he first t ransm it t ed m essage in m essages wit h several fram es. Exam ple: Read access password > > URY01060102030405060708090A0BCD00000000000200000002 < < ury000000101060102030405060708090A0BCD000200000000 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 57 Ch a p t e r 7 Operation M - EPC sca n n in g The M com m and st art s t he scanning of t he EPC t ransponder locat ed in t he act ivat ed ant enna locat ed in t he read area. H o st r e a d e r CM D Re a de r I D Head I D 1 byt e 1 byt e R e a d e r h o st D a t a o f t h e p a r t i ci p a t i n g EP C O v e r h e a d r e sp o n se t e l e g r a m 2 ) t r a n sp o n d e r s 1 ) 2 ) CM D Re a d e r ID Fr a m e ID R e su l t 3 ) Ex f l a g 3 ) Ex t e n si o n s EP C 1 byt e 2 byt es 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. 2) The response of t he t ransponder is opt ional and only appears at result " 00" . 3) The result and Ex flag is only available in t he first t ransm it t ed m essage in m essages wit h several fram es. Exam ple: > > M01 < < m 0010001 Fram e- I D " 01" ; result " 00" and Ex flag " 01" 0106470000000000000000000000 0106270000000000000000000000 0106110000000000000000000000 0106490000000000000000000000 0106100000000000000000000000 0106230000000000000000000000 0106420000000000000000000000 0106080000000000000000000000 0106310000000000000000000000 0106290000000000000000000000 0106120000000000000000000000 0106 t he m issing 12 byt es are included in t he next m essage < < m 000 250000000000000000000000 0106480000000000000000000000 0106410000000000000000000000 0106380000000000000000000000 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 58 Ch a p t e r 7 Operation 0106280000000000000000000000 0106030000000000000000000000 0106170000000000000000000000 0106190000000000000000000000 0106400000000000000000000000 0106050000000000000000000000 0106090000000000000000000000 0106010000000000000000000000 0106240000000000000000000000 0106460000000000000000000000 0106260000000000000000000000 0106180000000000000000000000 0106390000000000000000000000 0106060000000000000000000000 > > M01 < < m 0000A Result 0x0A, since no t ransponder is available > > URM01 < < urm 0000A Result 0x0A, since no t ransponder is available > > URM01 < < urm 0000001 Fram e- I D "00" ; result " 00" and Ex flag " 01" 01060B0C090A0708050603040102 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 59 Ch a p t e r 7 Operation URB – EPC Bu lk r e a din g The com m and URB st art s a reading of EPC t ransponders over a predet erm ined period of t im e. The EPC of all det ect ed t ransponders is report ed aft er t he com plet ion of t he t im e. H o st r e a d e r CM D Re a d e r I D Head I D Bu l k t i m e URB 1 byt e 1 byt e 4 byt es R e a d e r h o st O v e r h e a d r e sp o n se t e l e g r a m 2 ) CM D Re a d e r ID Fr a m e ID R e su l t 3 ) urb 1 byt e 2 byt es 2 byt es D a t a o f t h e p a r t i ci p a t i n g EP C t r a n sp o n d e r s 1 ) 2 ) Ex fla g 3) 2 byt es Ex t e n si o n s EP C 0- 12 byt es ( 2n+ 1) * 2 byt es T r a n sponder error co d e Num ber N data w ords 2 byt es 2 byt es Data w ords N* 4 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. 2) The response of t he t ransponder is opt ional and only appears at result " 00" . 3) The result and Ex flag is only available in t he first t ransm it t ed m essage in m essages wit h several fram es. Exam ple: > > URB016400 ( read 100 m s ! ! ) < < urb0000001 0106010203040506070808080909 01060B0C090A0708050603040102 0106BBCC99AA7788556633441122 > > URB010064 < < urb0000A Result 0x0A, since no t ransponder is available Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 60 Ch a p t e r 7 Operation W – W r it e EPC code The W com m and st art s t he descript ion of t he EPC of a present EPC t ransponder. Only one EPC t ransponder should be locat ed in t he writ e area of t he ant enna when using t his com m and. H o st r e a d e r CM D Re a de r I D Head I D A cce ss w o r d EP C 1 byt e 1 byt e 8 byt es ( 2n+ 1) * 2 byt es R e a d e r h o st D a t a o f t h e p a r t i ci p a t i n g EP C t r a n sp o n d e r s 2 ) O v e r h e a d r e sp o n se t e l e g r a m CM D Re a de r ID Fr a m e ID R e su l t Ex flag Ex t e n si o n s EP C 1 ) T r a n sp o n d e r e r r o r co d e 1 byt e 2 byt es 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es 2 byt es 1) The t ransponder here delivers as a response t he EPC code which was previously program m ed. 2) The response of t he t ransponder is opt ional and only appears at result " 00" . Exam ple: Overwrit e EPC t ransponder wit h a new EPC code > > M01 ( read old EPC code) < < m 000000101060102030405060708090A0BCD > > W0100000000060102030405060708090A0B0C < < w000000101060102030405060708090A0BCD8B > > M01 ( read new EPC code) < < m 000000101060102030405060708090A0B0C Exam ple: Several t ransponders are in t he field; t he act ion is t herefore incorrect > > W0100000000060102030405060708090A0B0C < < w0000B Result 0x0B Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 61 Ch a p t e r 7 Operation UW W – W r it e da t a r a nge of a ll EPC t r a n spon de r s The UWW com m and st art s t o overwrit e t he defined dat a range of all EPC t ransponders locat ed in t he field. Several EPC t ransponders can be locat ed in t he writ e area of t he ant enna when using t his com m and. H o st r e a d e r CM D Re a de r ID Head I D A cce ss w ord M em ory bank Mem ory a d d r e ss N um ber of N dat a w ords Data w ords UWW 1 byt e 1 byt e 8 byt es 2 byt es 8 byt es 2 byt es N* 4 byt es R e a d e r h o st D a t a o f t h e p a r t i ci p a t i n g EP C O v e r h e a d r e sp o n se t e l e g r a m 2 ) t r a n sp o n d e r s 1 ) 2 ) CM D Re a de r ID Fr a m e ID R e su l t 3 ) Ex f l a g 3 ) Ex t e n si o n s EP C T r a n sp o n d e r e r r o r co d e uww 1 byt e 2 byt es 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. 2) The response of t he t ransponder is opt ional and only appears at result " 00" . 3) The result and Ex flag is only available in t he first t ransm it t ed m essage in m essages wit h several fram es. Exam ple: Overwrit e EPC t ransponder wit h a new EPC code > > UWW01000000000102000000060102030405060708090A0B0C < < uww000000101060B0C090A070805060304010200 Cont rol reading: > > M01 < < m 0000001 01060B0C090A0708050603040102 Exam ple: Overwrit e several EPC t ransponders wit h a new EPC code > > UWW01000000000102000000060102030405060708090A0B0C < < uww0000001 010600000000C006D9DDB233083000 010600000000C006D9DDB233083000 0106BBCC99AA778855663344112200 Cont rol reading: > > M01 < < m 0000001 01060B0C090A0708050603040102 01060B0C090A0708050603040102 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 62 Ch a p t e r 7 Operation 01060B0C090A0708050603040102 EPC: 02010403060508070A090C0B EPC: 02010403060508070A090C0B EPC: 02010403060508070A090C0B Exam ple: Writ e EPC t ransponder access code > > UWW0100000000000200000002FFFFFFFF < < uww00000010106BBCC99AA778855663344112200 Cont rol reading: > > X01FFFFFFFF000200000002 < < x00000010106BBCC99AA77885566334411220002FFFFFFFF Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 63 Ch a p t e r 7 Operation UW Z – W r it e da t a r a nge of a ll EPCt r a n spon de r s ( de fin e d EPC code ) The UWZ com m and st art s t o overwrit e t he defined dat a range of all EPC t ransponders locat ed in t he field t hat have a defined EPC code. Several EPC t ransponders can be locat ed in t he writ e area of t he ant enna when using t his com m and. H o st r e a d e r CM D Re a de r ID Head ID UWZ 1 byt e 1 byt e EP C ( 2n+ 1) * 2 byt es A cce ss w ord M em ory bank M em ory a d d r e ss Num ber N data w ords 8 byt es 2 byt es 8 byt es 2 byt es Data w ords N* 4 byt es R e a d e r h o st D a t a o f t h e p a r t i ci p a t i n g EP C O v e r h e a d r e sp o n se t e l e g r a m 2 ) t r a n sp o n d e r s 1 ) 2 ) CM D Re a de r ID Fr a m e ID R e su l t 3 ) Ex f l a g 3 ) Ex t e n si o n s EP C uwz 1 byt e 2 byt es 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es T r a n sp o n d e r e r r o r co d e 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. 2) The response of t he t ransponder is opt ional and only appears at result " 00" . 3) The result and Ex flag is only available in t he first t ransm it t ed m essage in m essages wit h several fram es. Exam ple: Overwrit e several EPC t ransponders wit h t he sam e EPC code > > UWZ01060B0C090A0708050603040102000000000102000000060102030 405060708090A0B0C < < uwz000000101060B0C090A070805060304010200 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 64 Ch a p t e r 7 Operation Cont rol reading: > > M01 < < m 0000001 01060B0C090A0708050603040102 EPC: 02010403060508070A090C0B > > M01 < < m 0000001 01060102030405060708090A0B0C 01060102030405060708090A0B0C 01060102030405060708090A0B0C EPC: 0C0B0A090807060504030201 EPC: 0C0B0A090807060504030201 EPC: 0C0B0A090807060504030201 > > UWZ01060102030405060708090A0B0C000000000102000000061122334 45566778899AABBCC < < uwz000000101060102030405060708090A0B0C00 > > M01 < < m 0000001 0106BBCC99AA7788556633441122 01060102030405060708090A0B0C 01060102030405060708090A0B0C > > UWZ01060102030405060708090A0B0C00000000010200000006112233445 566778899AABBCC < < uwz000000101060102030405060708090A0B0C00 > > UWZ01060102030405060708090A0B0C00000000010200000006112233445 566778899AABBCC < < uwz000000101060102030405060708090A0B0C00 > > UWZ01060102030405060708090A0B0C00000000010200000006112233445 566778899AABBCC < < uwz0000A > > M01 < < m 0000001 0106BBCC99AA7788556633441122 0106BBCC99AA7788556633441122 0106BBCC99AA7788556633441122 EPC: 2211443366558877AA99CCBB EPC: 2211443366558877AA99CCBB EPC: 2211443366558877AA99CCBB Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 65 Ch a p t e r 7 Operation UM W – W r it e da t a r a nge of a ll EPC t r a n spon de r s The UMW com m and st art s t o overwrit e t he defined dat a range of all EPC t ransponders locat ed in t he field. Several EPC t ransponders can be locat ed in t he writ e area of t he ant enna when using t his com m and. m a sk e d H o st r e a d e r CM D Re a de r ID Head ID A cce ss w ord M em ory bank M em ory a d d r e ss N um ber of dat a w ords Data w ords M a sk UMW 1 byt e 1 byt e 8 byt es 2 byt es 8 byt es 2 byt es N* 4 byt es N* 4 byt es R e a d e r h o st D a t a o f t h e p a r t i ci p a t i n g EP C O v e r h e a d r e sp o n se t e l e g r a m 2 ) t r a n sp o n d e r s 1 ) 2 ) CM D Re a de r ID Fr a m e ID R e su l t 3 ) Ex f l a g 3 ) Ex t e n si o n s EP C T r a n sp o n d e r e r r o r co d e um w 1 byt e 2 byt es 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. 2) The response of t he t ransponder is opt ional and only appears at result " 00" . 3) The result and Ex flag is only available in t he first t ransm it t ed m essage in m essages wit h several fram es. Exam ple: The EPC t ransponder m asks 1 dat a word of t he EPC code, rewrit e > > M01 < < m 00000010106BBCC99AA7788556633441122 EPC: 2211443366558877AA99CCBB > > UMW01000000000102000000011111FFFF < < um w00000010106BBCC99AA778855663344112200 > > M01 < < m 00000010106BBCC99AA7788556633441111 EPC: 1111443366558877AA99CCBB Exam ple: The EPC t ransponder m asks 2 dat a words of t he EPC code, rewrit e > > UMW0100000000010200000002AABBCCDD0F0F0F0F < < um w00000010106BBCC99AA778855663344111200 > > M01 < < m 00000010106BBCC99AA778855663C4D1A1B EPC: 1B1A4D3C66558877AA99CCBB Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 66 Ch a p t e r 7 Operation UM Z – W r it e da t a r a nge of a ll EPCt r a n spon de r s ( de fin e d EPC code ) The UMZ com m and st art s t o overwrit e t he defined dat a range of all EPC t ransponders locat ed in t he field t hat have a defined EPC code. Several EPC t ransponders can be locat ed in t he writ e area of t he ant enna when using t his com m and. m a sk e d H o st r e a d e r CM D Re a de r ID Head ID UMZ 1 byt e 1 byt e EP C ( 2n+ 1) * 2 byt es A cce ss w ord Mem ory bank M em ory a d d r e ss Num ber of dat a w ords 8 byt es 2 byt es 8 byt es 2 byt es Data w ords M a sk N* 4 byt es N* 4 byt es R e a d e r h o st D a t a o f t h e p a r t i ci p a t i n g EP C O v e r h e a d r e sp o n se t e l e g r a m 2 ) t r a n sp o n d e r s 1 ) 2 ) CM D Re a d e r ID Fr a m e ID R e su l t 3 ) Ex f l a g 3 ) Ex t e n si o n s EP C um z 1 byt e 2 byt es 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es T r a n sp o n der error co d e 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. 2) The response of t he t ransponder is opt ional and only appears at result " 00" . 3) The result and Ex flag is only available in t he first t ransm it t ed m essage in m essages wit h several fram es. Exam ple: The EPC t ransponder m asks 2 dat a words of t he EPC code, rewrit e > > M01 < < m 000000101060102030405060708090A0B0C EPC: 0C0B0A090807060504030201 > > UMZ01060102030405060708090A0B0C000000000102000000029999888 80F0F0F0F < < um z000000101060102030405060708090A0B0C00 > > M01 < < m 00000010106010203040506070808080909 EPC: 090908080807060504030201 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 67 Ch a p t e r 7 Operation UBW – Er a se block of a ll EPC t r a n spon de r s The UBW com m and st art s t o delet e ( erase) t he defined blocks of all EPC t ransponders locat ed in t he field. Several EPC t ransponders can be locat ed in t he writ e area of t he ant enna when using t his com m and. H o st r e a d e r CM D Re a de r I D Head I D A cce ss w ord M em ory bank Mem ory a d d r e ss N um be r of N dat a w ords UBW 1 byt e 1 byt e 8 byt es 2 byt es 8 byt es 2 byt es R e a d e r h o st D a t a o f t h e p a r t i ci p a t i n g EP C O v e r h e a d r e sp o n se t e l e g r a m 2 ) t r a n sp o n d e r s 1 ) 2 ) CM D Re a de r I D Fr a m e I D R e su l t 3 ) Ex f l a g 3 ) Ex t e n si o n s EP C ubw 1 byt e 2 byt es 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es T r a n sp o n der error co d e 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. 2) The response of t he t ransponder is opt ional and only appears at result " 00" . 3) The result and Ex flag is only available in t he first t ransm it t ed m essage in m essages wit h several fram es. Exam ple: 2 dat a words of t he user area of an EPC t ransponder are delet ed > > M01 < < m 000000101060B0C090A0708050603040102 > > UBW01060B0C090A070805060304010200000000030000000002 < < ubw000000101060B0C090A070805060304010200 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 68 Ch a p t e r 7 Operation UBZ – Er a se block of a ll EPC t r a n spon de r s ( de fin e d EPC code ) The UBZ com m and st art s t o delet e ( erase) t he defined dat a range of all EPC t ransponders locat ed in t he field t hat have a defined EPC code. Several EPC t ransponders can be locat ed in t he writ e area of t he ant enna when using t his com m and. H o st r e a d e r CM D Re a de r ID Head I D EP C UBZ 1 byt e 1 byt e ( 2n+ 1) * 2 byt es A cce ss w ord M em ory bank M em ory a d d r e ss N um ber of N data w ords 8 byt es 2 byt es 8 byt es 2 byt es R e a d e r h o st D a t a o f t h e p a r t i ci p a t i n g EP C O v e r h e a d r e sp o n se t e l e g r a m 2 ) t r a n sp o n d e r s 1 ) 2 ) CM D Re a de r ID Fr a m e ID R e su l t 3 ) Ex f l a g 3 ) Ex t e n si o n s EP C ubz 1 byt e 2 byt es 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es T r a n sp o n d e r e r r o r co d e 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. 2) The response of t he t ransponder is opt ional and only appears at result " 00" . 3) The result and Ex flag is only available in t he first t ransm it t ed m essage in m essages wit h several fram es. Exam ple: 2 dat a words of t he user area of an EPC t ransponder are delet ed > > M01 < < m 000000101060B0C090A0708050603040102 > > UBZ01060B0C090A070805060304010200000000030000000002 < < ubz000000101060B0C090A070805060304010200 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 69 Ch a p t e r 7 Operation ULW – Lock in g a ll The ULW com m and st art s t o lock t he defined dat a range of all EPC t ransponders EPC t r a n spon de r s locat ed in t he field. Several EPC t ransponders can be locat ed in t he writ e area of t he ant enna when using t his com m and. H o st r e a d e r CM D Re a de r I D Head I D A cce ss w o r d Pa yloa d ULW 1 byt e 1 byt e 8 byt es 6 byt es R e a d e r h o st D a t a o f t h e p a r t i ci p a t i n g EP C O v e r h e a d r e sp o n se t e l e g r a m 2 ) t r a n sp o n d e r s 1 ) 2 CM D Re a de r ID Fr a m e ID R e su l t 3 ) Ex f l a g 3 ) Ex t e n si o n s EP C ulw 1 byt e 2 byt es 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es T r a n sp o n d e r e r r o r co d e 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. 2) The response of t he t ransponder is opt ional and only appears at result " 00" . 3) The result and Ex flag is only available in t he first t ransm it t ed m essage in m essages wit h several fram es. Exam ple: Lock t he ACCESS block of an EPC t ransponder Payload 0x0300C0; Perm alock= 1 > > ULW01FFFFFFFFC00003 < < ulw00000010106BBCC99AA778855663344112200 Since Perm alock was set , t he kill password cannot be read or writ t en aft er t he locking process! > > UWW0100000000000200000002FFFFFFFE < < uww00000010106BBCC99AA778855663344112284 > > UWW01FFFFFFFF000200000002FEFEFEFE < < uww00000010106BBCC99AA778855663344112284 Access area can no longer be writ t en! Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 70 Ch a p t e r 7 Operation ULZ – Lock in g a ll EPC t r a n spon de r s ( de fin e d EPC code ) The ULZ com m and st art s t o lock all EPC t ransponders wit h t he corresponding EPC code locat ed in t he field. Several EPC t ransponders can be locat ed in t he writ e area of t he ant enna when using t his com m and. H o st r e a d e r CM D Re a de r I D Head I D EP C A cce ss w o r d Pa yloa d ULZ 1 byt e 1 byt e ( 2n+ 1) * 2 byt es 8 byt es 6 byt es R e a d e r h o st D a t a o f t h e p a r t i ci p a t i n g EP C O v e r h e a d r e sp o n se t e l e g r a m 2 ) t r a n sp o n d e r s 1 ) 2 ) CM D Re a de r ID Fr a m e ID R e su l t 3 ) Ex f l a g 3 ) Ex t e n si o n s EP C T r a n sp o n d e r e r r o r co d e ulz 1 byt e 2 byt es 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. 2) The response of t he t ransponder is opt ional and only appears at result " 00" . 3) The result and Ex flag is only available in t he first t ransm it t ed m essage in m essages wit h several fram es. Exam ple: Lock t he Kill block of an EPC t ransponder > > UWW0100000000000000000002FEFEFEFE < < uww00000010106BBCC99AA778855663344112200 Kill password writ t en Payload 0x0C00C0; Perm alock= 1 > > ULZ0106BBCC99AA7788556633441122FFFFFFFF00030C < < ulz00000010106BBCC99AA778855663344112200 Since Perm alock was set , t he kill password cannot be read or writ t en aft er t he locking process! > > UWW0100000000000000000002FEFEFEFE < < uww00000010106BBCC99AA778855663344112284 Kill password can no longer be writ t en! Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 71 Ch a p t e r 7 Operation UKW – Killin g a ll The UKW com m and st art s t o kill t he defined dat a range of all EPC t ransponders EPC t r a n spon de r s locat ed in t he field. Several EPC t ransponders can be locat ed in t he writ e area of t he ant enna when using t his com m and. The " kill" com m and is only perform ed for a t ransponder if t he kill password was previously writ t en and m at ches! The t ransponder can no longer be addressed aft er a successful kill com m and. H o st r e a d e r CM D Re a de r I D Head I D K i l l p a ssw o r d R e co m m i ssi o n UKW 1 byt e 1 byt e 8 byt es 2 byt es R e a d e r h o st D a t a o f t h e p a r t i ci p a t i n g EP C O v e r h e a d r e sp o n se t e l e g r a m 2 ) t r a n sp o n d e r s 1 ) 2 ) CM D Re a d e r ID Fr a m e ID R e su l t 3 ) Ex f l a g 3 ) Ex t e n si o n s EP C ukw 1 byt e 2 byt es 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es T r a n sp o n d e r e r r o r co d e 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. 2) The response of t he t ransponder is opt ional and only appears at result " 00" . 3) The result and Ex flag is only available in t he first t ransm it t ed m essage in m essages wit h several fram es. Exam ple: Kill an EPC t ransponder > > UKW01FEFEFEFEFE < < ukw000000101060102030405060708090A0B0C00 > > UKW01FEFEFEFEFE < < ukw0000A The t ransponder no longer responds! > > M01 < < m 0000A The t ransponder no longer responds! I M PORTAN T The respect ive t ransponder can no longer be addressed aft er a successfully conduct ed kill com m and. This com m and cannot be undone. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 72 Ch a p t e r 7 Operation UKZ – Killin g a ll EPC t r a n spon de r s ( de fin e d EPC code ) The UKZ com m and st art s t o kill all EPC t ransponders wit h t he corresponding EPC code locat ed in t he field. Several EPC t ransponders can be locat ed in t he writ e area of t he ant enna when using t his com m and. The kill com m and is only perform ed if t he kill password was previously writ t en! The t ransponder can no longer be addressed aft er a successful kill com m and. H o st r e a d e r CM D Re a de r I D Head I D EP C Ki l l p a ssw o r d R e co m m i ssi o n UKZ 1 byt e 1 byt e ( 2n+ 1) * 2 byt es 8 byt es 2 byt es R e a d e r h o st D a t a o f t h e p a r t i ci p a t i n g EP C O v e r h e a d r e sp o n se t e l e g r a m 2 ) t r a n sp o n d e r s 1)2) CM D Re a de r I D Fr a m e ID R e su l t 3 ) Ex f l a g 3 ) Ex t e n si o n s EP C ukz 1 byt e 2 byt es 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es T r a n sp o n d e r e r r o r co d e 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. 2) The response of t he t ransponder is opt ional and only appears at result " 00" . 3) The result and Ex flag is only available in t he first t ransm it t ed m essage in m essages wit h several fram es. EPC: 2211443366558877AA99CCBB Exam ple: Kill an EPC t ransponder > > M01 < < m 00000010106BBCC99AA7788556633441122 > > UKZ0106BBCC99AA7788556633441122FEFEFEFEFE < < ukz00000010106BBCC99AA778855663344112200 The t ransponder no longer responds! > > UKZ0106BBCC99AA7788556633441122FEFEFEFEFE < < ukz0000A > > M01 < < m 0000A The t ransponder no longer responds! > > M01 < < m 0000A The t ransponder no longer responds! Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 73 Ch a p t e r 7 Operation I M PORTAN T The respect ive t ransponder can no longer be addressed aft er a successfully conduct ed kill com m and. This com m and cannot be undone. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 74 Ch a p t e r 7 Operation T a n d UAM – En a ble r e a d pollin g EPC The T or UAM com m and st art s t he polling of EPC t ransponders on t he respect ive ant enna port , as long as it is not ended or t he device is not reset ! ! Transponder m essages only appear if EPC t ransponders are act ually m oved in t he field. The polling is briefly st opped for int erm ediat e read request s and is cont inued aft er t he act ion. I f polling is act ivat ed via param et er " polling port " 0x28, polling is rest art ed aut om at ically aft er reset . Only t he so- called t ransponder m essages appear when act ivat ing polling per param et er. H o st r e a d e r CM D Re a de r I D Head I D UAM 1 byt e 1 byt e CM D Re a de r I D R e su l t uam 1 byt e 2 byt es R e a d e r h o st ( co n f i r m a t i o n ) R e a d e r h o st ( t r a n sp o n d e r m e ssa g e ) O v e r h e a d r e sp o n se t e l e g r a m D a t a o f t h e EP C t r a n sp o n d e r CM D Re a de r I D D i r e ct i o n Ex f l a g Ex t e n si o n s EP C uam 1 byt e 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es Re a din g cy cl e s 1 ) 2 byt es 1) These dat a are displayed when t ransponders are m oved out of t he field. Exam ple: > > P02901 ( UHFshow Going act ive) < < p0 > > UAM01 < < uam 000 < < uam 0FF010106BBCC99AA7788556633441122 EPC t ransponder ent ers t he field: 2211443366558877AA99CCBB < < uam 0FF010106010203040506070808080909 EPC t ransponder ent ers t he field: 090808080706050403020106 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 75 Ch a p t e r 7 Operation < < uam 000010106BBCC99AA77885566334411225502 EPC t ransponder leaves t he field: EPC: 2211443366558877AA99CCBB < < uam 0000101060102030405060708080809095C02 EPC t ransponder leaves t he field: 090908080807060504030201 < < uam 0FF010106010203040506070808080909 EPC t ransponder ent ers t he field: 090908080807060504030201 < < uam 0000101060102030405060708080809090500 EPC t ransponder leaves t he field: 090908080807060504030201 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 76 Ch a p t e r 7 Operation UAA – En a ble Re a d Polling Ra w The UAA com m and st art s t he polling of EPC t ransponders on t he respect ive ant enna port , as long as it is not ended or t he device is not reset ! Wit h each polling run all t ransponders are shown - which m ay result in a high dat a t raffic. The polling is briefly st opped for int erm ediat e read request s and is cont inued aft er t he act ion. I f polling is act ivat ed via param et er " polling port " 0x28, polling is rest art ed aut om at ically aft er reset . Only t he so- called t ransponder m essages appear when act ivat ing polling per param et er. H o st r e a d e r CM D Re a de r I D Head I D UAA 1 byt e 1 byt e CM D Re a de r I D R e su l t uaa 1 byt e 2 byt es R e a d e r h o st ( co n f i r m a t i o n ) R e a d e r h o st ( t r a n sp o n d e r m e ssa g e ) O v e r h e a d r e sp o n se t e l e g r a m D a t a o f t h e EP C t r a n sp o n d e r CM D Re a de r I D D i r e ct i o n Ex f l a g Ex t e n si o n s EP C uaa 1 byt e 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es Re a ding cy cl e s 1 ) 2 byt es 1) These dat a are displayed when t ransponders are m oved out of t he field. Exam ple: > > UAA01 < < uaa000 < < uaa0FF010106BBCC99AA7788556633441122 EPC t ransponder ent ers t he field: 2211443366558877AA99CCBB < < uaa0FF010106010203040506070808080909 EPC t ransponder ent ers t he field: 090808080706050403020106 < < uaa000010106BBCC99AA77885566334411225502 EPC t ransponder leaves t he field: EPC: 2211443366558877AA99CCBB < < uaa0000101060102030405060708080809095C02 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 77 Ch a p t e r 7 Operation EPC t ransponder leaves t he field: 090908080807060504030201 < < uaa0FF010106010203040506070808080909 EPC t ransponder ent ers t he field: 090908080807060504030201 < < uaa0000101060102030405060708080809090500 EPC t ransponder leaves t he field: 090908080807060504030201 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 78 Ch a p t e r 7 Operation UAX – Pollin g Re a d Data The UAX com m and st art s t he asynchronous read ( polling) of a defined dat a range of EPC t ransponders at t he respect ive ant enna port . The polling read dat a is execut ed as long as it is not ended or a reset is execut ed. Transponder m essages only appear if EPC t ransponders are act ually m oved in t he field. The polling is briefly st opped for int erm ediat e read request s and is cont inued aft er t he act ion. H o st r e a d e r CM D Re a de r I D Head I D A cce ss w o r d M em ory bank M em ory a d d r e ss N um be r of dat a w ords UAX 1 byt e 1 byt e 8 byt es 2 byt es 8 byt es 2 byt es R e a d e r h o st ( co n f i r m a t i o n ) CM D Re a de r I D R e su l t uax 1 byt e 2 byt es R e a d e r h o st ( t r a n sp o n d e r m e ssa g e ) O v e r h e a d r e sp o n se t e l e g r a m D a t a o f t h e EP C t r a n sp o n d e r CM D Re a de r I D D i r e ct i o n Ex f l a g Ex t e n si o n s EP C uax 1 byt e 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es Re a ding cy cl e s 1 ) 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. 2) Dat a of t he t ransponder are opt ional; t hey appear only at t ransponder error code " 00" . Exam ple: Read EPC ( m em ory bank 01, address 02000000, lengt h 06) > > UAX0100000000010200000006 < < uax000 Polling successfully init iat ed < < uax000 << uax0FF010106BBCC99AA77885566334411220006112233445566778899AABBC < < uax000010106BBCC99AA77885566334411221100 << uax0FF010106BBCC99AA77885566334411220006112233445566778899AABBC Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 79 Ch a p t e r 7 Operation << uax0FF0101060102030405060708080809090006090908080708050603040102 < < uax000010106BBCC99AA77885566334411224700 << uax0FF010106BBCC99AA77885566334411220006112233445566778899AABBC < < uax000010106BBCC99AA77885566334411222400 < < uax0000101060102030405060708080809097100 > > UAE0 < < uae000 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 80 Ch a p t e r 7 Operation UAW – Polling W r it e D a t a The UAW com m and st art s t he asynchronous writ ing ( polling) of a defined dat a range of EPC t ransponders at t he respect ive ant enna port . The polling writ e dat a is execut ed as long as it is not ended or a reset is execut ed. Transponder m essages only appear if EPC t ransponders are act ually m oved in t he field. The polling is briefly st opped for int erm ediat e read request s and is cont inued aft er t he act ion. H o st r e a d e r CM D Re a de r ID Head ID A cce ss w ord Mem ory bank Mem ory a d d r e ss N um ber of N data w ords Data w ords UAW 1 byt e 1 byt e 8 byt es 2 byt es 8 byt es 2 byt es N* 4 byt es R e a d e r h o st ( co n f i r m a t i o n ) CM D Re a de r I D R e su l t uaw 1 byt e 2 byt es R e a d e r h o st ( t r a n sp o n d e r m e ssa g e ) D a t a o f t h e p a r t i ci p a t i n g EP C t r a n sp o n d e r s 1 ) O v e r h e a d r e sp o n se t e l e g r a m CM D Re a de r ID D i r e ct i o n Ex f l a g Ex t e n si o n s EP C Re a din g cy cl e s uaw 1 byt e 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. Exam ple: Writ e EPC ( m em ory bank 01, address 02000000, lengt h 06) > > UAW01000000000102000000060102030405060708090A0B0C < < uaw000 Polling successfully init iat ed < < uaw0FF010106BBCC99AA778855663344112200 << << << << << << << << uaw000010106BBCC99AA77885566334411220500 uaw0FF0101060B0C090A070805060304010200 uaw0000101060B0C090A07080506030401023000 uaw0FF01010601020304050607080808090900 uaw0000101060102030405060708080809090500 uaw0FF0101060B0C090A070805060304010200 uaw0000101060B0C090A07080506030401020700 uaw0FF0101060B0C090A070805060304010200 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 81 Ch a p t e r 7 Operation < < uaw0000101060B0C090A07080506030401024E00 > > UAE0 < < uae000 St op polling Cont rol reading: > > M01 < < m 0000001 01060B0C090A0708050603040102 01060B0C090A0708050603040102 EPC: 02010403060508070A090C0B EPC: 02010403060508070A090C0B Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 82 Ch a p t e r 7 Operation UAZ – Pollin g W r it e The UAZ com m and st art s t he asynchronous m asked writ ing ( polling) of a defined M a sk e d D a t a dat a range of EPC t ransponders at t he respect ive ant enna port . The polling writ e m asked dat a is execut ed as long as it is not ended or a reset is execut ed. Transponder m essages only appear if EPC t ransponders are act ually m oved in t he field. The polling is briefly st opped for int erm ediat e read request s and is cont inued aft er t he act ion. H o st r e a d e r CM D Re a de r ID Head ID A cce ss w ord M em ory bank M em ory a d d r e ss N um ber of N data w ords UAZ 1 byt e 1 byt e 8 byt es 2 byt es 8 byt es 2 byt es Data w ords M a sk N* 4 byt es N* 4 byt es R e a d e r h o st ( co n f i r m a t i o n ) CM D Re a de r I D R e su l t uaz 1 byt e 2 byt es R e a d e r h o st ( t r a n sp o n d e r m e ssa g e ) D a t a o f t h e p a r t i ci p a t i n g EP C t r a n sp o n d e r s 1 ) O v e r h e a d r e sp o n se t e l e g r a m CM D Re a de r I D D i r e ct i o n Ex f l a g Ex t e n si o n s EP C Re a din g cy cl e s uaz 1 byt e 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. Exam ple: 1 dat a word of t he EPC m asked writ e ( m em ory bank 01, address 02000000, lengt h 01, m ask FFFF) > > M01 < < m 000000101060B0C090A0708050603040102 EPC: 02010403060508070A090C0B > > UAZ01000000000102000000011122FFFF < < uaz000 Polling successfully init iat ed < < uaz000 < < uaz0FF0101060B0C090A070805060304010200 < < uaz0000101060B0C090A07080506030401020500 < < uaz0FF0101060B0C090A070805060304112200 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 83 Ch a p t e r 7 Operation < < uaz0000101060B0C090A07080506030411224E00 > > UAE0 < < uae000 St op polling > > M01 < < m 000000101060B0C090A0708050603041122 EPC: 22110403060508070A090C0B Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 84 Ch a p t e r 7 Operation UAB – Er a se Block The UAB com m and st art s t he asynchronous erase block ( polling) of a defined dat a range of EPC t ransponders at t he respect ive ant enna port . The polling erase block is execut ed as long as it is not ended or a reset is execut ed. Transponder m essages only appear if EPC t ransponders are act ually m oved in t he field. The polling is briefly st opped for int erm ediat e read request s and is cont inued aft er t he act ion. I M PORTAN T Erasing a block is only support ed by a few t ransponders at t his t im e! H o st r e a d e r CM D Re a de r ID Head ID EP C A cce ss w ord M em ory bank M em ory a d d r e ss N um ber of N dat a w ords UAB 1 byt e 1 byt e ( 2n+ 1) * 2 byt es 8 byt es 2 byt es 8 byt es 2 byt es R e a d e r h o st ( co n f i r m a t i o n ) CM D Re a de r I D R e su l t uab 1 byt e 2 byt es R e a d e r h o st ( t r a n sp o n d e r m e ssa g e ) D a t a o f t h e p a r t i ci p a t i n g EP C t r a n sp o n d e r s 1 ) O v e r h e a d r e sp o n se t e l e g r a m CM D Re a de r I D D i r e ct i o n Ex f l a g Ex t e n si o n s EP C T r a n sp o n d e r e r r o r co d e uab 1 byt e 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. Exam ple: Delet e 2 dat a words of t he USER m em ory area ( m em ory bank 03, address 00000000, lengt h 02) > > UAB0100000000030000000002 < < uab000 Polling successfully init iat ed < < uab0FF0101060B0C090A070805060304112200 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 85 Ch a p t e r 7 Operation UAL – Lock EPC The UAL com m and st art s t he asynchronous lock EPC ( polling) of defined EPC t ransponders at t he respect ive ant enna port . The polling lock EPC is execut ed as long as it is not ended or a reset is execut ed. Transponder m essages only appear if EPC t ransponders are act ually m oved in t he field. The polling is briefly st opped for int erm ediat e read request s and is cont inued aft er t he act ion. H o st r e a d e r CM D Re a de r I D Head I D A cce ss w o r d Pa y loa d UAL 1 byt e 1 byt e 8 byt es 6 byt es R e a d e r h o st ( co n f i r m a t i o n ) CM D Re a de r I D R e su l t ual 1 byt e 2 byt es R e a d e r h o st ( t r a n sp o n d e r m e ssa g e ) D a t a o f t h e p a r t i ci p a t i n g EP C t r a n sp o n d e r s 1 ) O v e r h e a d r e sp o n se t e l e g r a m CM D Re a de r I D D i r e ct i o n Ex f l a g Ex t e n si o n s EP C T r a n sp o n d e r e r r o r co d e ual 1 byt e 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. Exam ple: Lock kill password ( Payload 0x0C0300 Perm alock= 1) > > UWW0100000000000000000002FEFEFEFE < < uww000000101000005358004D9DDB233083000 Kill password writ t en > > UAL010000000000030C < < ual000 Polling successfully init iat ed Since Perm alock was set , t he kill password cannot be read or writ t en aft er t he locking process! < < ual0FF010106000005358004D9DDB233083000 > > UWW0100000000000000000002FEFEFEFE < < uww00000010106000005358004D9DDB233083084 Transponder error 0x84: Kill password is locked! Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 86 Ch a p t e r 7 Operation UAK – Kill EPC t r a n spon de r The UAK com m and st art s t he asynchronous kill of EPC t ransponders ( polling) at t he respect ive ant enna port . The polling kill EPC is execut ed as long as it is not ended or a reset is execut ed. Transponder m essages only appear if EPC t ransponders are act ually m oved in t he field. The polling is briefly st opped for int erm ediat e read request s and is cont inued aft er t he act ion. The " kill" com m and is only perform ed for a t ransponder if t he kill password was previously writ t en and m at ches! The t ransponder can no longer be addressed aft er a successful kill com m and. H o st r e a d e r CM D Re a de r I D Head I D K i l l p a ssw o r d R e co m m i ssi o n UAK 1 byt e 1 byt e 8 byt es 2 byt es R e a d e r h o st ( co n f i r m a t i o n ) CM D Re a de r I D R e su l t uak 1 byt e 2 byt es R e a d e r h o st ( t r a n sp o n d e r m e ssa g e ) D a t a o f t h e p a r t i ci p a t i n g EP C t r a n sp o n d e r s 1 ) O v e r h e a d r e sp o n se t e l e g r a m CM D Re a de r ID D i r e ct i o n Ex f l a g Ex t e n si o n s EP C T r a n sp o n d e r e r r o r co d e uak 1 byt e 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. Exam ple: Kill EPC t ransponder > > UAK01FEFEFEFE00 < < uak000 Polling successfully init iat ed < < uak0FF010106000005358004D9DDB233083000 EPC t ransponder successfully m ade unreadable! The t ransponder no longer responds! Addit ional exam ple: > > UAK010000000000 < < uak000 Polling successfully init iat ed < < uak0FF0101060B0C090A070805060304112280 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 87 Ch a p t e r 7 Operation < < uak0FF0101060B0C090A070805060304112280 < < uak0FF0101060B0C090A070805060304112280 < < uak0FF0101060B0C090A070805060304112280 Kill password not set < < uak0FF010106000005358004D9DDB233083002 Wrong Kill password I M PORTAN T The respect ive t ransponder can no longer be addressed aft er a successfully conduct ed kill com m and. This com m and cannot be undone. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 88 Ch a p t e r 7 Operation UAR – Polling t r a nsponde r r a t e The UAR com m and provides t he t ransponder rat e of t he act ivat ed polling act ion. A t ransponder list of a st andard invent ory is first est ablished in t he reader in all polling act ions before t he act ual read/ writ e act ion is execut ed. The t ransponder rat e is form ed via t he invent ory and specifies how m any t ransponders are det ect ed per second during t he invent ory. H o st r e a d e r CM D Re a de r I D Head I D UAR 1 byt e 1 byt e R e a d e r h o st CM D Re a de r I D R e su l t T r a n sp o n d e r r a t e uar 1 byt e 2 byt es 4 byt es Exam ple: Read t ransponder rat e at various t im es < < n0 > > UAR01 < < uar0000000 > > UAM01 < < uam 000 Polling Get EPCs st art ed! < < uam 0FF0101060B0C090A0708050603040102 EPC: 02010403060508070A090C0B < < uam 0FF010106370000000000000000000000 EPC: 000000000000000000000037 < < uam 0FF010106069905358004D9DDB2330830 EPC: 300833B2DDD9048035059906 < < uam 0FF010106089905358004D9DDB2330830 EPC: 300833B2DDD9048035059908 < < uam 0FF010106160000000000000000000000 EPC: 000000000000000000000016 < < uam 0FF010106380000000000000000000000 EPC: 000000000000000000000038 < < uam 0FF010106060000000000000000000000 EPC: 000000000000000000000006 < < uam 0FF010106140000000000000000000000 EPC: 000000000000000000000014 < < uam 0FF010106400000000000000000000000 EPC: 000000000000000000000040 < < uam 0FF010106079905358004D9DDB2330830 EPC: 300833B2DDD9048035059907 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 89 Ch a p t e r 7 Operation < < uam 0FF010106050000000000000000000000 EPC: 000000000000000000000005 < < uam 0FF010106340000000000000000000000 EPC: 000000000000000000000034 < < uam 0FF010106180000000000000000000000 EPC: 000000000000000000000018 < < uam 0FF010106430000000000000000000000 EPC: 000000000000000000000043 < < uam 0FF010106109905358004D9DDB2330830 EPC: 300833B2DDD9048035059910 < < uam 0FF010106170000000000000000000000 EPC: 000000000000000000000017 < < uam 0FF010106420000000000000000000000 EPC: 000000000000000000000042 < < uam 0FF010106070000000000000000000000 EPC: 000000000000000000000007 < < uam 0FF010106330000000000000000000000 EPC: 000000000000000000000033 < < uam 0FF010106150000000000000000000000 EPC: 000000000000000000000015 < < uam 0FF010106520000000000000000000000 EPC: 000000000000000000000052 < < uam 0FF010106390000000000000000000000 EPC: 000000000000000000000039 < < uam 0FF010106080000000000000000000000 EPC: 000000000000000000000008 < < uam 0FF010106410000000000000000000000 EPC: 000000000000000000000041 < < uam 0FF010106230000000000000000000000 < < uar0006C00 < < uam 0FF010106230000000000000000000000 EPC: 000000000000000000000023 > > UAR01 < < uar0007800 EPC: 000000000000000000000023 > > UAR01 < < uar0005800 > > UAR01 < < uar0005800 > > UAR01 < < uar0005900 > > UAR01 < < uar0006100 > > UAR01 < < uar0006100 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 90 Ch a p t e r 7 Operation > > UAR01 < < uar0006C00 > > UAR01 < < uar0006C00 > > UAR01 < < uar0006C00 < < uam 0FF010106230000000000000000000000 EPC: 000000000000000000000023 > > UAR01 < < uar0007800 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 91 Ch a p t e r 7 Operation UAE – En d polling The UAE com m and ends all asynchronous com m ands ( polling) at all ant enna port s. I f t he polling was st art ed per polling port param et er, t he param et er m ust also be reset t o finally end t his. H o st r e a d e r CM D Re a de r I D UAE 1 byt e R e a d e r h o st CM D Re a de r I D R e su l t uae 1 byt e 2 byt es Exam ple: end current polling act ion > > UAE0 < < uae000 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 92 Ch a p t e r 7 Operation UCX – Act iva t e polling N XPUCOD E- G2 X Re a d Pr ot e ct The UCX com m and st art s t he asynchronous t ransponder funct ion ( polling operat ion) " ReadProt ect " of all NXP- UCODE- G2X t ransponders in t he field at t he respect ive ant enna port . The polling " ReadProt ect " is execut ed as long as it is not ended or a reset is execut ed. Transponder m essages only appear if NXP- UCODE- G2X t ransponders are act ually m oved in t he field. The polling is briefly st opped for int erm ediat e read request s and is cont inued aft er t he act ion. H o st r e a d e r CM D Re a de r I D Head I D A cce ss w o r d UCX 1 byt e 2 byt es 8 byt es R e a d e r h o st ( co n f i r m a t i o n ) CM D Re a de r I D R e su l t ucx 1 byt e 2 byt es R e a d e r h o st ( t r a n sp o n d e r m e ssa g e ) D a t a o f t h e p a r t i ci p a t i n g EP C t r a n sp o n d e r s 1 ) O v e r h e a d r e sp o n se t e l e g r a m CM D Re a de r ID D i r e ct i o n Ex f l a g Ex t e n si o n s EP C T r a n sp o n d e r e r r o r co d e ucx 1 byt e 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. Exam ple: > > UCX0100000000 < < ucx000 < < ucx0FF0101060B0C090A070805060304112200 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 93 Ch a p t e r 7 Operation UCN – Act iva t e polling N XPUCOD E- G2 X Re se t Re a d Pr ot e ct The UCN com m and st art s t he asynchronous t ransponder funct ion ( polling operat ion) " Reset ReadProt ect " of all NXP- UCODE- G2X t ransponders in t he field at t he respect ive ant enna port . The polling " Reset ReadProt ect " is execut ed as long as it is not ended or a reset is execut ed. Transponder m essages only appear if NXP- UCODE- G2X t ransponders are act ually m oved in t he field. The polling is briefly st opped for int erm ediat e read request s and is cont inued aft er t he act ion. H o st r e a d e r CM D Re a de r I D Head I D A cce ss w o r d UCN 1 byt e 1 byt e 8 byt es R e a d e r h o st ( co n f i r m a t i o n ) CM D Re a de r I D R e su l t ucn 1 byt e 2 byt es R e a d e r h o st ( t r a n sp o n d e r m e ssa g e ) D a t a o f t h e p a r t i ci p a t i n g EP C t r a n sp o n d e r s 1 ) O v e r h e a d r e sp o n se t e l e g r a m CM D Re a de r ID D i r e ct i o n Ex f l a g Ex t e n si o n s EP C T r a n sp o n d e r e r r o r co d e ucn 1 byt e 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. Exam ple: > > UCN0100000000 < < ucn000 < < ucn0FF0101060B0C090A070805060304112200 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 94 Ch a p t e r 7 Operation UCC - Act iva t e The UCC com m and st art s t he asynchronous t ransponder funct ion ( polling Polling N XP- operat ion) " Change EAS" of all NXP- UCODE- G2X t ransponders in t he field at t he UCOD E- G2 X respect ive ant enna port . The polling " Change EAS" is execut ed as long as it is not Cha n ge EAS ended or a reset is execut ed. Transponder m essages only appear if NXP- UCODE- G2X t ransponders are act ually m oved in t he field. The polling is briefly st opped for int erm ediat e read request s and is cont inued aft er t he act ion. H o st r e a d e r CM D Re a de r I D Head I D A cce ss w o r d EA S a l a r m b i t UCC 1 byt e 1 byt e 8 byt es 2 byt es R e a d e r h o st ( co n f i r m a t i o n ) CM D Re a de r I D R e su l t ucc 1 byt e 2 byt es R e a d e r h o st ( t r a n sp o n d e r m e ssa g e ) D a t a o f t h e p a r t i ci p a t i n g EP C t r a n sp o n d e r s 1 ) O v e r h e a d r e sp o n se t e l e g r a m CM D Re a d e r I D D i r e ct i o n Ex f l a g Ex t e n si o n s EP C T r a n sp o n d e r e r r o r co d e ucc 1 byt e 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es 2 byt es 1) These dat a are displayed in t he order list ed for each ident ified EPC t ransponder. Exam ple: > > UCC010000000001 < < ucc000 < < ucc0FF0101060B0C090A070805060304112200 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 95 Ch a p t e r 7 Operation UCE - Act iva t e polling N XPUCOD E- G2 X EAS a la r m The UCE com m and st art s t he asynchronous t ransponder funct ion ( polling operat ion) " EAS alarm " of all NXP- UCODE- G2X t ransponders in t he field at t he respect ive ant enna port . The polling " EAS alarm " is execut ed as long as it is not ended or a reset is execut ed. Transponder m essages only appear if NXP- UCODE- G2X t ransponders are act ually m oved in t he field. The polling is briefly st opped for int erm ediat e read request s and is cont inued aft er t he act ion. H o st r e a d e r CM D Re a d e r I D Head I D UCE 1 byt e 1 byt e R e a d e r h o st ( co n f i r m a t i o n ) CM D Re a de r I D R e su l t uce 1 byt e 2 byt es R e a d e r h o st ( t r a n sp o n d e r m e ssa g e ) O v e r h e a d r e sp o n se t e l e g r a m D a t a o f t h e EP C t r a n sp o n d e r CM D Re a de r I D D i r e ct i o n Ex f l a g Ex t e n si o n s EP C uce 1 byt e 2 byt es 2 byt es 0- 12 byt es ( 2n+ 1) * 2 byt es Exam ple: > > UCE01 < < uce000 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 96 Ch a p t e r 7 Operation UFW – Se t filt e r da t a By set t ing and act ivat ing so- called filt ers, it is possible t o only let cert ain EPC t ransponders part icipat e in t he invent ory. A t ot al of 8 filt ers can be defined. The UFW com m and m akes it possible t o set t he dat a for a filt er. H o st r e a d e r CM D Re a de r ID Fi l t e r Num ber On/ Off Ta rget A ct i o n 1) UFW 1 byt e 2 byt es 2 byt es 2 byt es 1) M em ory bank M em ory a d d r e ss Num ber o f m a sk bit s N 2 byt es 2 byt es 8 byt es 2 byt es Fi l t e r m a sk 2 * Round up ( N / 8) byt es 1) See EPC Global specificat ion " Select com m and" for a descript ion R e a d e r h o st CM D Re a de r I D R e su l t Fi l t e r N u m b e r ufw 1 byt e 2 byt es 2 byt es Exam ple: > > UFW001000000010200000010F0F0 < < ufw00001 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 97 Ch a p t e r 7 Operation UFR – Re a d filt e r da t a By set t ing and act ivat ing filt ers, it is possible t o only let cert ain EPC t ransponders part icipat e in t he invent ory. A t ot al of 32 filt ers can be defined. The UFR com m and allows reading of dat a of a filt er. H o st r e a d e r CM D Re a d e r I D Fi l t e r N u m b e r UFR 1 byt e 2 byt es R e a d e r h o st CM D Re a de r ID R e su l t Fi l t e r N um ber On/ Off ufr 1 byt e 2 byt es 2 byt es byt es 1) M em ory bank M em ory a d d r e ss Num ber o f m a sk bit s N 2 byt es 2 byt es 8 byt es 2 byt es Target A ct i o n 1) 2 byt es Fi l t e r m a sk 2 * Round up ( N / 8) byt es 1) See EPC Global specificat ion " Select com m and" for a descript ion Exam ple: > > UFR001 < < ufr00001000000010200000010F0F0 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 98 Ch a p t e r 7 Operation UFP – Se t filt e r By set t ing and act ivat ing so- called filt ers, it is possible t o only let cert ain EPC t ransponders part icipat e in t he invent ory. A t ot al of 32 filt ers can be defined. The use of a part icular filt er can be swit ched on and off by t he UFP com m and. H o st r e a d e r CM D Re a de r ID Fi l t e r Num ber On/ Off Ta rget A ct i o n 1) UFP 1 byt e 2 byt es 2 byt es 2 byt es 1) M em ory bank M em ory a d d r e ss Num ber o f m a sk bit s N 2 byt es 2 byt es 8 byt es 2 byt es Fi l t e r m a sk 2 * Round up ( N / 8) byt es 1) See EPC Global specificat ion " Select com m and" for a descript ion R e a d e r h o st CM D Re a de r I D R e su l t Fi l t e r N u m b e r ufp 1 byt e 2 byt es 2 byt es Exam ple: Act ivat e filt er 01 > > UFP001FF < < ufp00001 Filt er 01 was act ivat ed > > UFG001 < < ufg00001FF Current st at us of filt er 01 > > UFR001 < < ufr00001FF0000010200000010F0F0 Cont rol read of filt er dat a 01 Exam ple: Deact ivat e filt er 01 > > UFP00100 < < ufp00001 Filt er 01 was deact ivat ed Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 99 Ch a p t e r 7 Operation UFG – Re a d filt e r da t a By set t ing and act ivat ing so- called filt ers, it is possible t o only let cert ain EPC t ransponders part icipat e in t he invent ory. A t ot al of 32 filt ers can be defined. The st at us of a part icular filt er can be det erm ined by t he UFG com m and. H o st r e a d e r CM D Re a de r I D Fi l t e r N u m b e r UFG 1 byt e 2 byt es R e a d e r h o st CM D Re a de r I D R e su l t Fi l t e r N u m b e r On/ Off ufg 1 byt e 2 byt es 2 byt es 2 byt es Exam ple: Read st at us of filt er 01 > > UFG001 < < ufg0000100 ” 00” : Filt er 01 is not act ive UFP001FF < < ufp00001 Filt er 01 was act ivat ed > > UFG001 < < ufg00001FF " FF" : Filt er 01 is act ive Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 100 Ch a p t e r 7 Operation UGL – Re a d list of The radio profiles locat ed in t he reader can be read wit h t he UGL com m and. The r a dio pr ofile s profiles are num bered consecut ively. The profile descript ion it self is ASCI I - coded and is always com plet ed by a zero byt e 0x00. H o st r e a d e r CM D Re a de r I D UGL 1 byt e R e a d e r h o st D a t a o f t h e r e sp e ct i v e p r o f i l e 1 ) 2 ) O v e r h e a d r e sp o n se t e l e g r a m CM D Re a de r I D R e su l t 3 ) Pr ofile num ber A SCI I p r o f i l e d e scr i p t i o n Zero byt es ugl 1 byt e 2 byt es 2 byt es 2* N Byt es 00 1) These dat a are displayed in t he order list ed for each ident ified profile. 2) The descript ion of t he profiles is opt ional and only appears at result " 00" . 3) The result flag is only available in t he first t ransm it t ed m essage in m essages wit h several fram es. Exam ple: Read radio profile list of t he reader > > UGL0 < < ugl000 0054783A34306B6270732F52783A38306B6270732F464D3000 0154783A34306B6270732F52783A34306B6270732F4D696C6C65723200025 4783A34306B6270732F52783A3136306B6270732F464D3000 0354783A34306B6270732F52783A38306B6270732F4D696C6C65723200045 4783A34306B6270732F52783A34306B6270732F4D696C6C65723400 Radio profiles: 0x00 0x01 0x02 0x03 0x04 – – – – – Tx: 40kbps/ Rx: 80kbps/ FM0 Tx: 40kbps/ Rx: 40kbps/ Miller2 Tx: 40kbps/ Rx: 160kbps/ FM0 Tx: 40kbps/ Rx: 80kbps/ Miller2 Tx: 40kbps/ Rx: 40kbps/ Miller4 ( default set t ing) Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 101 Ch a p t e r 7 Operation UGP – Re a d a ct ive The current ly used radio profile can be read in t he reader wit h t he UGP com m and. r a dio pr ofile H o st r e a d e r CM D Re a de r I D UGP 1 byt e R e a d e r h o st CM D Re a de r I D Pr ofile n u m be r ugp 1 byt e 2 byt es Exam ple: Read act ive radio profile of t he reader > > UGP0 < < ugp004 Default set t ing of radio profile 0x04 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 102 Ch a p t e r 7 Operation UPP – Se t a ct ive The act ive radio profile of t he reader can be set wit h t he UPP com m and. r a dio pr ofile H o st r e a d e r CM D Re a de r I D Pr ofile n u m be r UPP 1 byt e 2 byt es CM D Re a de r I D R e su l t upp 1 byt e 2 byt es R e a d e r h o st Exam ple: Set profile > > UPP003 < < upp000 Profile successfully set > > UGP0 < < ugp003 Current profile read > > UPP005 < < upp004 Profile num ber out of range > > UGP0 < < ugp003 Current profile read Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 103 Ch a p t e r 7 Operation UN H – H a r dw a r e r e se t The UNH com m and perform s a hardware reset of t he whole UHF reader. Approxim at ely 20 seconds pass aft er a confirm at ion unt il t he reset is com plet ed and t he reader responds wit h a reset m essage. H o st r e a d e r CM D Re a de r I D UNH 1 byt e R e a d e r h o st ( co n f i r m a t i o n ) CM D Re a de r I D R e su l t unh 1 byt e 2 byt es R e a d e r h o st ( r e se t m e ssa g e ) CM D Re a de r I D 1 byt e Exam ple: > > UNH0 < < unh000 ...up t o 20 seconds pass... < < n0 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 104 Ch a p t e r 7 Operation UN R or N – Soft w a r e r e se t The UNR or N com m and only t riggers a rest art of t he soft ware. Aft er t he soft ware is reset , t he device responds wit h a reset m essage. H o st r e a d e r CM D Re a de r I D UNR 1 byt e R e a d e r h o st ( co n f i r m a t i o n ) CM D Re a de r I D R e su l t unr 1 byt e 2 byt es R e a d e r h o st ( r e se t m e ssa g e ) CM D Re a de r I D 1 byt e Exam ple 1: > > N0 < < n0 Exam ple 2: > > UNR0 < < unr000 < < n0 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 105 Ch a p t e r 7 Operation UPE - Fa ct or y Re se t / Fa ct or y Se t t in g There are 3 opt ions t o com plet ely or only part ially reset t he device t o t he default st at us. 1. Only reader- specific param et ers ( from param et er 100) are reset by t he " UPE" com m and. H o st r e a d e r CM D Re a de r I D UPE 1 byt e R e a d e r h o st CM D Re a de r I D upe 1 byt e Exam ple: > > UPE0 < < upe000 2. The com plet e reader is set t o t he default st at us by t he Fact oryReset param et er ( 0x63) and a reset is t hen perform ed! Reset wit h param et er: > > P06300 < < p0 < < n0 3. I f t he " Modi" and " Reset " but t ons are sim ult aneously pressed at a powerup reset for about 15 seconds unt il all t he LEDs of t he foil keypad light up for t he second t im e, t he com plet e reader will be reset t o t he default st at e. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 106 Ch a p t e r 7 Operation F – Pa r a m e t e r qu e r y The F com m and is used t o query individual param et ers of t he device. The num ber of t he param et er is t ransm it t ed in " Param et er No." . The response cont ains t he param et er num ber and value. The param et er num ber and t he value should be specified in HEX form at : for exam ple, param et er 11 0x0B. H o st r e a d e r CM D Re a de r I D Pa r a m e t e r no.1 ) 1 byt e 2 byt es R e a d e r h o st CM D Re a de r I D Pa r a m e t e r no. Pa r a m e t e r va lu e 1 byt e 2 byt es N* 2 byt es 1) I f a param et er num ber is not specified, t he reader will provide all reader param et ers. A single response t elegram is t hen sent for each param et er. The param et er value can be m ult i- digit ( N> = 1) ! Exam ple: > > F02A ( request param et er 0x2A) < < f02A0F > > F0 ( request all param et ers) < < f000A2 < < f001C9 …… < < f07905 < < f07A01 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 107 Ch a p t e r 7 Operation P – Se t pa r a m e t e r The P com m and set s t he individual param et er values of t he device. The device sends a confirm at ion aft er successfully set t ing a param et er. The param et er num ber and t he value should be specified in HEX form at : e.g. param et er 11 0x0B. I M PORTAN T Aft er set t ing one or several param et ers, a reset is t o be carried out as som e param et ers affect hardware set t ings. H o st r e a d e r CM D Re a de r I D Pa r a m e t e r N o Pa r a m e t e r va lu e 1 byt e 2 byt es N* 2 byt es R e a d e r h o st CM D Re a de r I D 1 byt e The param et er value can be m ult i- digit ( N> = 1) ! Exam ple: > > F014 ( read old value 0x00) < < f01400 > > P0140F ( set value from 0x00 t o 0x0F) < < p0 > > F014 ( read new value 0x0F) < < f0140F Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 108 Ch a p t e r 7 Operation N - Re se t I M PORTAN T The N com m and perform s a reset of t he reader hardware. Aft er t he reset t he Et hernet connect ion t o t he device has t o be reest ablished. Aft er set t ing one or several param et ers, a reset is t o be carried out as som e param et ers affect hardware set t ings. H o st r e a d e r CM D Re a de r I D 1 byt e Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 109 Ch a p t e r 7 Operation UGK – D e t e r m in e For t he t ypical reader param et ers ( param et er num ber 100 t o m ax. 240) , up t o 8 a ct ive pa r a m e t e r param et er set s can be creat ed and select ed. Aft er st art ing t he reader, t he default se t param et er set will aut om at ically becom e t he act ive param et er set . Any changes t o t he reader param et ers only affect t he act ive param et er set . The act ive param et er set can be det erm ined by t he UGK com m and. H o st r e a d e r CM D Re a de r I D UGK 1 byt e R e a d e r h o st CM D Re a de r I D P a r a m e t e r se t n o . ugk 1 byt e 2 byt es Exam ple: < < n0 ( Powerup reset ) > > UGK0 < < ugk000 Act ive param et er set num ber 00 ( default value) Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 110 Ch a p t e r 7 Operation UPK – D e fine t h e For t he t ypical reader param et ers ( param et er num ber 100 t o m ax. 240) , up t o 8 a ct ive pa r a m e t e r param et er set s can be creat ed and select ed. Aft er st art ing t he reader, t he default se t param et er set will aut om at ically becom e t he act ive param et er set . Any changes t o t he reader param et ers only affect t he act ive param et er set . The act ive param et er set can be det erm ined by t he UPK com m and. H o st r e a d e r CM D Re a de r I D P a r a m e t e r se t n o . UPK 1 byt e 2 byt es CM D Re a de r I D R e su l t upk 1 byt e 2 byt es R e a d e r h o st Exam ple: < < n0 ( Powerup reset ) > > UGK0 < < ugk000 Act ive param et er set num ber 00 ( default value) > > UPK007 < < upk000 New act ive param et er set was successfully defined > > UGK0 < < ugk007 Act ive param et er set num ber 07 > > P06A84 < < p0 Transm ission out put of Port 1 changed from 0x6c t o 0x84 ( param et er set 7! ) ... Poweroff reset ... < < n0 > > UGK0 < < ugk000 > > F06A < < f06A6C The default param et er is loaded aft er a reset Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 111 Ch a p t e r 7 Operation > > UPK007 < < upk000 > > F06A < < f06A84 The t ransm ission out put of param et er set 7 has t he value 0x84 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 112 Ch a p t e r 7 Operation UGD – D e t e r m in e For t he t ypical reader param et ers ( param et er num ber 100 t o m ax. 240) , up t o 8 de fa ult pa r a m e t e r param et er set s can be creat ed and select ed. The default param et er set is t he one se t t hat is loaded when st art ing t he reader and aut om at ically becom es t he act ive param et er set . The param et er set num ber ( 0 t o 7) of t he default param et er set can be det erm ined wit h t he UGD com m and. R e a d e r h o st CM D Re a de r I D UGD 1 byt e H o st r e a d e r CM D Re a de r I D P a r a m e t e r se t n o . ugd 1 byt e 2 byt es Exam ple: > > UGD0 < < ugd000 Default param et er set num ber 00 ( default value) Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 113 Ch a p t e r 7 Operation UPD – D e fine For t he t ypical reader param et ers ( param et er num ber 100 t o m ax. 240) , up t o 8 de fa ult pa r a m e t e r param et er set s can be creat ed and select ed. The default param et er set is t he one se t t hat is loaded when st art ing t he reader and aut om at ically becom es t he act ive param et er set . The param et er set num ber ( 0 t o 7) of t he default param et er set can be defined wit h t he UPD com m and. I f t he UPD com m and has a param et er set num ber great er t han 7, t he current ly act ive param et er set is used as t he default param et er set . R e a d e r h o st CM D Re a de r I D P a r a m e t e r se t n o . UPD 1 byt e 2 byt es CM D Re a de r I D R e su l t upd 1 byt e 2 byt es H o st r e a d e r Exam ple: set new default param et er > > UPD007 < < upd000 Default param et er set num ber successfully set > > UGD0 < < ugd007 Default param et er set num ber 07 .... Poweroff reset .... < < n0 > > UGD0 < < ugd007 Default param et er set num ber 07 Exam ple: Set default param et er set as t he act ive param et er set > > UGD0 < < ugd007 Default param et er set num ber 07 > > UGK0 < < ugk007 Act ive param et er set num ber 07 > > UPK000 < < upk000 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 114 Ch a p t e r 7 Operation Act ive param et er set 00 successfully set > > UPD008 < < upd000 Act ive param et er set is st ored as t he default param et er set ! > > UGK0 < < ugk000 Act ive param et er set 00 > > UGD0 < < ugd000 Default param et er set 00 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 115 Ch a p t e r 7 Operation B – Se n sor st a t u s The B com m and is t ransm it t ed by t he reader if t he st at us of a sensor has changed. The m essage shows t he current st at us of t he sensor. The host m ust send or not send ( Par Wat ch port Bit 6) a confirm at ion depending on t he int ernal set t ing of t he reader. R e a d e r h o st CM D Re a de r I D Head I D Se n so r st a t e 1 byt e 1 byt e 1 byt e H o st r e a d e r CM D Re a de r I D Head I D 1 byt e 1 byt e Exam ple: Sensor det ect ed, EPC bulk reading, sensor rem oved < < B011 < < URB000000101060B0C090A070805060304010201060B0C090A0708050603 041122 < < B010 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 116 Ch a p t e r 7 Operation O – Se t out pu t The O com m and changes t he st at us of t he respect ive ant enna port . H o st r e a d e r CM D Re a de r I D Head I D O u t p u t st a t e 1 byt e 1 byt e 1 byt e R e a d e r h o st CM D Re a de r I D Head I D 1 byt e 1 byt e Exam ple: >> << >> << >> << >> << >> << O010 Set out put 1 o01 O020 Set out put 2 o02 O032 Set out put 3 o03 O044 Set out put 4 o04 Q00 Cont rol query q000124 " Off " " On" " Flash" " Fast flashing" Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 117 Ch a p t e r 7 Operation Q – Que r ie s of t he out pu t st a t u s The current st at us of an out put can be queried by using t he Q com m and. The st at us of t he out put s of a single ant enna port or t he ent ire device can be queried. For a single ant enna port , t he reader report s t he st at us of t he out put . Use t he Head I D 0 t o query t he st at us of all out put s of t he reader. The st at us of each out put is represent ed by 3 charact ers ( st at us + flash rat e) . H o st r e a d e r CM D Re a de r I D Head I D 1 byt e 1 byt e R e a d e r h o st CM D Re a de r I D Head I D O u t p u t st a t e 1 byt e 1 or 4 Byt es 1 or 4 Byt es Exam ple: ( Query aft er reset , no out put was set ) > > Q01 < < q013 > > Q02 < < q023 > > Q03 < < q033 > > Q04 < < q043 > > Q00 < < q003333 Exam ple: I / Os were set > > O010 < < o01 > > O011 < < o01 > > O021 < < o02 > > O031 < < o03 > > O041 < < o04 > > Q00 < < q001111 > > Q01 < < q011 > > Q02 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 118 Ch a p t e r 7 Operation << >> << >> << q021 Q03 q031 Q04 q041 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 119 Ch a p t e r 7 Operation E – Er r or m e ssa ge I f an error occurs, t he device sends an error m essage wit h a suit able error code. This m essage m ust be confirm ed by t he host ( depending on device set t ing param et er) . H o st r e a d e r CM D Re a de r I D Er r o r I D 1 byt e 1 byt e R e a d e r h o st CM D Re a de r I D 1 byt e For m ore inform at ion on error codes and t he corresponding correct ing act ions, please refer t o Error codes. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 120 Ch a p t e r 7 Operation H – H e a r t be a t The H com m and can be used t o query t he serial num ber of t he device. H o st r e a d e r CM D Re a de r I D 1 byt e R e a d e r h o st CM D Re a de r I D Se r i a l n u m b e r R e sp o n se co d e 1 byt e 4 byt es 4 byt es The response code is not required for t he individual device. This code is always " 0000" . Exam ple: > > H0 < < h012340000 Serial num ber: 1234 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 121 Ch a p t e r 7 Operation UVR or V – The V com m and queries t he soft ware version of t he device. Que r y soft w a r e ve r sion H o st r e a d e r CM D Re a de r I D 1 byt e R e a d e r h o st CM D Re a de r I D So f t w a r e v e r si o n uvr 1 byt e 2* x Byt es The x charact ers for t he soft ware version are illust rat ed by 2* x ASCI I charact ers. Each of t he x charact ers is shown in t he HEX form at , represent ed by 2 ASCI I charact ers. Exam ple: > > V0 < < v0554846493230 Soft ware version: UHFI 20 > > F063 < < f06300 Fine version 0 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 122 Ch a p t e r 7 Operation UGT – Re a d UTC The UGT com m and reads t he t im e in UTC form at . t im e H o st r e a d e r CM D Re a de r I D UGT 1 byt e R e a d e r h o st CM D Re a de r I D UTC t im e ugt 1 byt e 8 byt es Exam ple: > > UGT0 < < ugt 01462A348 Reader t im e: 13.08.2008 22: 37: 08 > > UGT0 < < ugt 01F62A348 Reader t im e: 13.08.2008 22: 37: 19 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 123 Ch a p t e r 7 Operation UPT – Se t UTC t im e The UPT com m and set s t he t im e in UTC form at . H o st r e a d e r CM D Re a de r I D UTC t im e UPT 1 byt e 8 byt es CM D Re a de r I D R e su l t upt 1 byt e 2 byt es R e a d e r h o st Exam ple: > > UPT05F65A348 < < upt 000 > > UGT0 < < ugt 06865A348 Reader t im e: 13.08.2008 22: 51: 20 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 124 Ch a p t e r 7 Operation Se nsor t r igge r e d a u t om a t ic r e a din g The response can be set for each of t he four input s by param et ers ( 26 t o 29) Wat ch port . An aut om at ic reading can also be aut om at ically init iat ed on t he respect ive ant enna, in addit ion t o sensor m essage " B" . An EPC bulk reading "urb" is perform ed over a set t im e period as an aut om at ic reading. The t im e fram e can be set via param et er ( 33 and 34) Aut o read Bulk t im e. Exam ple: < < B011 Sensor st at us at sensor 1 is "On" < < URB0000001 Result 0x00 and ext ension 0x01 01060B0C090A0708050603041122 01060B0C090A0708050603040102 < < B010 Sensor st at us at sensor 1 is "Off " < < B021 Sensor st at us at sensor 1 is "On" < < URB0000A Result 0x0A no t ransponder is det ect ed < < B020 Sensor st at us at sensor 1 is "Off " Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 125 Ch a p t e r 7 Operation 7 .2 .4 No ( d e c. ) Pa r a m e t e r s No ( hex) Pa r a m e t e r n a m e 0x00 Com m unicat ions port 0x01 Baud rat e 0x03 Parit y ( read only) 0x04 MsgRepeat Delay Tim e 0x06 MsgMaxRepeat 0x07 First byt e of t he serial num ber ( read only) 0x08 Second byt e of t he serial num ber ( read only) 11 0x0B Reader I D 12 0x0C Acknowledgm ent Error Message 20 0x14 Sensor act ivit y 21 0x15 Delay t im e for sensor 1 22 0x16 Delay t im e for sensor 2 23 0x17 Delay t im e for sensor 3 24 0x18 Delay t im e for sensor 4 26 0x1A Wat ch port for sensor 1 27 0x1B Wat ch port for sensor 2 28 0x1C Wat ch port for sensor 3 29 0x1D Wat ch port for sensor 4 33 0x21 High- byt e Aut o Read Bulk Tim e 34 0x22 Low- byt e Aut o Read Bulk Tim e 39 0x27 Adj ust I / O num bering 40 0x28 Polling port 41 0x29 Show UHF Going 93 0x5D Wait Tim e Reader Response ( read only) 94 0x5E Wait Tim e Reader Acknowledge ( read only) 95 0x5F Reader Cont rol Tim e ( read only) 96 0x60 St op Aut om at ic Read ( read only) Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 126 Ch a p t e r 7 Operation No ( d e c. ) No ( hex) Pa r a m e t e r n a m e 97 0x61 St op Sensor Message ( read only) 98 0x62 Error ‘Unexpect ed’ ( read only) 99 0x63 Fact ory Reset / Fine Version 100 0x64 Global ETSI Channel List 101 0x65 ETSI Channel List Ant enna 1 102 0x66 ETSI Channel List Ant enna 2 103 0x67 ETSI Channel List Ant enna 3 104 0x68 ETSI Channel List Ant enna 4 105 0x69 Channel Swit ching Mode 106 0x6A Transm ission Out put Ant enna Port 1 107 0x6B Transm ission Out put Ant enna Port 2 108 0x6C Transm ission Out put Ant enna Port 3 109 0x6D Transm ission Out put Ant enna Port 4 110 0x6E Ant enna cable port 1 at t enuat ion 111 0x6F Ant enna cable port 2 at t enuat ion 112 0x70 Ant enna cable port 3 at t enuat ion 113 0x71 Ant enna cable port 4 at t enuat ion 114 0x72 Ant enna gain port 1 115 0x73 Ant enna gain port 2 116 0x74 Ant enna gain port 3 117 0x75 Ant enna gain port 4 118 0x76 Ext ended Result Flag 119 0x77 Glim psed Tim eout Count 120 0x78 Observed Threshold Count 121 0x79 Observed Tim eout Count 122 0x7A Com m unicat ions st andard 123 0x7B ETSI Power Check Over All Allowed Channels 124 0x7C Com m St andard Cent er Freq CH0 125 0x7D Com m St andard Channel Widt h Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 127 Ch a p t e r 7 Operation No ( d e c. ) No ( hex) Pa r a m e t e r n a m e 126 0x7E Com m St andard Max Channel Tim e 127 0x7F Com m St andard Min Channel Wait Tim e 128 0x80 Com m St andard First Channel 129 0x81 Com m St andard Last Channel 130 0x82 Tag Com m I nt elligent Writ e 131 0x83 Tag Com m Verify Writ e 132 0x84 Tag Com m Query Target 133 0x85 Tag Com m Query Sel 134 0x86 Host Com m Ant enna I ndependend Operat ion 135 0x87 RF I nt erface Tim e t o Power Off 136 0x88 RF I nt erface Modulat ion Type 137 0x89 RF I nt erface Mult iplexing Ant enna Port 1 138 0x8A RF I nt erface Mult iplexing Ant enna Port 2 139 0x8B RF I nt erface Mult iplexing Ant enna Port 3 140 0x8C RF I nt erface Mult iplexing Ant enna Port 4 141 0x8D RF I nt erface Mult iplexing Ant enna Port 5 142 0x8E RF I nt erface Mult iplexing Ant enna Port 6 143 0x8F RF I nt erface Mult iplexing Ant enna Port 7 144 0x90 RF I nt erface Mult iplexing Ant enna Port 8 145 0x91 RF I nt erface RSSI Threshold 1 146 0x92 RF I nt erface RSSI Threshold 2 147 0x93 RF I nt erface RSSI Threshold 3 148 0x94 RF I nt erface RSSI Threshold 4 149 0x95 RF I nt erface Mult ipower Tag Access 1 150 0x96 RF I nt erface Mult ipower Tag Access 2 151 0x97 RF I nt erface Mult ipower Tag Access 3 152 0x98 RF I nt erface Mult ipower Tag Access 4 153 0x99 RF I nt erface Max Allowed Ant enna Out put Power 1 154 0x9A RF I nt erface Max Allowed Ant enna Out put Power 2 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 128 Ch a p t e r 7 Operation No ( d e c. ) No ( hex) Pa r a m e t e r n a m e 155 0x9B RF I nt erface Max Allowed Ant enna Out put Power 3 156 0x9C RF I nt erface Max Allowed Ant enna Out put Power 4 157 0x9D Tag Com m Use Pilot Tone 158 0x9E Tag Com m I nit ial Q 159 0x9F Tag Com m Session 160 0xA0 Tag Com m Max Errors 161 0xA1 Tag Com m Default Profile 162 0xA2 RF I nt erface Mult iplexing Exposure Tim e 1 163 0xA3 RF I nt erface Mult iplexing Exposure Tim e 2 164 0xA4 RF I nt erface Mult iplexing Exposure Tim e 3 165 0xA5 RF I nt erface Mult iplexing Exposure Tim e 4 166 0xA6 RF I nt erface Mult iplexing Exposure Tim e 5 167 0xA7 RF I nt erface Mult iplexing Exposure Tim e 6 168 0xA8 RF I nt erface Mult iplexing Exposure Tim e 7 169 0xA9 RF I nt erface Mult iplexing Exposure Tim e 8 170 0xAA RF I nt erface Enable RSSI Threshold At Specific Cm ds 171 0xAB RF I nt erface Flash Writ e Addit ional Power 172 0xAC Tag Com m Force Power Off Aft er EPC Writ e 173 0xAD Tag Com m Transm it Get EPCs Pre Select 174 0xAE Tag Com m Transm it Select I f No Filt er I s On 175 0xAF Tag Com m Num ber Of EPC Words 176 0xBO Tag Com m Use Block Writ e 177 0xB1 Tag Com m Disable Receiving NXP Read Prot ect ed Tags 178 0xB2 Host Com m A Sync Addit ional RSSI Dat a Delivery Delt a 179 0xB3 Host Com m Use Milliseconds As Tim e st am p Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 129 Ch a p t e r 7 Operation Pa r a m e t e r 0 ( 0x00) Co m m u n i ca t i o n s p o r t I f t he highest value bit 0x80 is set , t he device aut om at ically det ect s t he act ive com m unicat ions port . A reset m ust be com plet ed t o change t he com m unicat ions port . The first m essage t o t he reader m ust t hen com e via t he new com m unicat ions port . 0x11: Host reader: Reader host : 0x13: Host reader: Reader host : 0x22: Host reader: Reader host : 0x23: Host reader: Reader host : Et hernet Et hernet Et hernet Et hernet and RS232 RS232 RS232 RS232 Et hernet and RS232 Default : ( 0xA2) aut om at ic det ect ion of t he com m unicat ion port Pa r a m e t e r 0 1 ( 0x01) Ba u d r a t e Dat a t ransm ission rat e 0x0C: 0x18: 0x30: 0x60: 0xC0: 0xC8: 0xC9: 1,200 Baud 2,400 Baud 4,800 Baud 9,600 Baud 19,200 Baud 38,400 Baud 57,600 Baud Default : ( 0xC9) 57,600 Baud ( See accom panying let t er) Pa r a m e t e r 0 3 ( 0x03) Pa r it y ( r e a d on ly) Param et er of t he RS232 com m unicat ion port Param et er can only be read in t he default st at e! Values: Even parit y Uneven parit y No parit y Default : ( 0x02) No parit y Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 130 Ch a p t e r 7 Operation Pa r a m e t e r 0 4 ( 0x04) M sg R e p e a t D e l a y T i m e I f a confirm at ion is not sent by t he host , t he device wait s t his t im e span before it sends t he m essage t o t he host again. The num ber of repet it ions is defined in param et er 6 ( MsgMaxRepeat ) . 10 .. 250 [ 0.1 s] Default : 0x32 ( 5 s) Pa r a m e t e r 0 6 ( 0x06) M sg M a x R e p e a t I f a confirm at ion is not sent by t he host , t he device repeat s t he m essage according t o t he set value. Only t hen is an error m essage sent . 0 – 31 Default : 0x03 Pa r a m e t e r 0 7 ( 0x07) Fi r st b y t e o f t h e se r i a l n u m b e r ( r e a d o n l y ) Represent s t he first byt e of t he serial num ber Device label. This value is writ e prot ect ed! Pa r a m e t e r 0 8 ( 0x08) Se co n d b y t e o f t h e se r i a l n u m b e r ( r e a d o n l y ) Represent s t he second byt e of t he serial num ber Device label. This value is writ e prot ect ed! Pa r a m e t e r 1 1 ( 0 x 0 B) Re a de r I D This param et er defines t he address of t he device in t he ASC- I 1 prot ocol. 0 .. E Default : 0x00 Pa r a m e t e r 1 2 ( 0 x 0 C) A ck n o w l e d g m e n t Er r o r M e ssa g e This param et er defines whet her an error m essage m ust be confirm ed or not . 0 – No confirm at ion expect ed 1 – a confirm at ion is expect ed Default : 0x01 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 131 Ch a p t e r 7 Operation Pa r a m e t e r 2 0 ( 0x14) Se n so r a ct i v i t y The device offers t he opt ion t o disable t he sensor input s. 0x00000000 All 4 sensors are disabled 0x00000001 0x00011111 Sensor 1 is act ivat ed All 4 sensors are act ivat ed Default : 0x00001111 ( 0F) all sensors are act ivat ed Pa r a m e t e r 2 1 ( 0x15) D e l a y t i m e f o r se n so r 1 This param et er defines t he delay t im e for sensor signal before t he event m essage is sent . 1 .. 255 1/ 10 s Default : 0x01 ( 1 x 0.1 s = 0.1 s) Pa r a m e t e r 2 2 ( 0x16) Pa r a m e t e r 2 3 ( 0x17) Pa r a m e t e r 2 4 ( 0x18) D e l a y t i m e f o r se n so r 2 See param et er 21. D e l a y t i m e f o r se n so r 3 See param et er 21. D e l a y t i m e f o r se n so r 4 See param et er 21. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 132 Ch a p t e r 7 Operation Pa r a m e t e r 2 6 ( 0 x 1 A) W a t ch p o r t f o r se n so r 1 This param et er defines t he response of t he device when t riggering t he respect ive input . I M PORTAN T The sensor m ust be connect ed t o t he input , in order t o use t his response! Bit 0: 0 – m essage input open disabled 1 – m essage input open act ivat ed Bit 1: 0 – m essage input closed disabled 1 – m essage input closed act ivat ed Bit 4/ 5: 0 – no scanning 1 – EPC bulk reading Bit 6: 0 – The device does not expect any confirm at ion from t he host 1 – The device expect s a confirm at ion from t he host Bit 7: 0 – The input signal is not invert ed ( norm al) 1 – The input signal is invert ed Default : 0b00110011 ( 0x33) Report " input open" and " closed" and sensort riggered EPC bulk reading. Pa r a m e t e r 2 7 ( 0 x 1 B) Pa r a m e t e r 2 8 ( 0 x 1 C) Pa r a m e t e r 2 9 ( 0x1D) Pa r a m e t e r 3 3 ( 0x21) W a t ch p o r t f o r se n so r 2 See param et er 26. W a t ch p o r t f o r se n so r 3 See param et er 26. W a t ch p o r t f o r se n so r 4 See param et er 26. H i g h - b y t e Au t o R e a d Bu l k T i m e An EPC bulk reading is com plet ed in t he sensor- t riggered aut om at ic reading. The durat ion of t he bulk reading is specified in m illiseconds. The high byt e of t he 2 byt e t im e value is defined here. 0 – 255 page Default : 0x01 ( 0x0100: 256 m s) Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 133 Ch a p t e r 7 Operation Pa r a m e t e r 3 4 ( 0x22) Lo w - b y t e A u t o R e a d Bu l k T i m e An EPC bulk reading is com plet ed in t he sensor- t riggered aut om at ic reading. The durat ion of t he bulk reading is specified in m illiseconds. The low byt e of t he 2 byt e t im e value is defined here. 0x1234 Lowbyt e 0x34 Default : 0x00 ( 0x0100: 256 m s) Pa r a m e t e r 3 9 ( 0x27) A d j u st I / O n u m b e r i n g Ant ennas and I / Os have t he sam e num bering. This applies for input s and out put s Sensor 1 t herefore becom es sensor 4 and vice versa. 0: Do not provide an adj ust m ent ( com pat ibilit y t o previous versions) 1: Adj ust I / Os Default : 0x01 Pa r a m e t e r 4 0 ( 0x28) Pollin g por t The ant enna port is defined wit h t his param et er, on which a polling EPC scan ( asynchronous EPC scanning) is perform ed. Polling is st art ed aft er a reset according t o t he value of t he param et er polling port . Value range: 0x00: 0x01: 0x02: 0x04: 0x08: 0x0F: No polling Polling EPC on Polling EPC on Polling EPC on Polling EPC on Polling EPC on ant enna 1 ant enna 2 ant enna 3 ant enna 4 all 4 ant ennas Default : 0x00 ( no polling) ATTEN TI ON I f polling is st opped by t he " UAE" com m and, t he param et er polling port is not affect ed. Polling is rest art ed according t o t he param et er at t he next reset . Reset t ing t he param et er t o value 0x00 st ops polling! Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 134 Ch a p t e r 7 Operation Pa r a m e t e r 4 1 ( 0x29) Sh o w U H F Go i n g When polling is act ivat ed by t he EPC t ransponders ( asynchronous reading) , t he det ect ion as well as t he rem oval of EPC t ransponders can be displayed. Value range: 0x00 t o 0x03 Bit 0 ( 0x01) : Bit 1 ( 0x02) : I n addit ion t o det ect ing also display t he rem oval of an EPC t ransponder During an invent ory display t he deviat ion of t he RSSI value t o t he am ount of t he value of t he configurat ion param et er ( Par. 0xB2) in com parison t o t he RSSI value of t he previous invent ory Default : 0x00 ( only show det ect ion) Pa r a m e t e r 9 3 ( 0x5D) W a i t T i m e R e a d e r R e sp o n se ( r e a d o n l y ) This int ernal param et er can only be read. Default : 0x9C ( count er 0x9C00) Pa r a m e t e r 9 4 ( 0 x 5 E) W a i t T i m e R e a d e r A ck n o w l e d g e ( r e a d o n l y ) This int ernal param et er can only be read. Default : 0x14 ( count er 0x1400) Pa r a m e t e r 9 5 ( 0 x 5 F) R e a d e r Co n t r o l T i m e ( r e a d o n l y ) This int ernal param et er can only be read. Default : 0x0A ( 1 s) Pa r a m e t e r 9 6 ( 0x60) St o p Au t o m a t i c R e a d ( r e a d o n l y ) I nt ernal param et er t hat can only be read. Set t ing t he int ernal param et er causes t he aut om at ic reading t o be t erm inat ed when t he sensor drops prem at urely. Default : 0x01 ( act ive) Pa r a m e t e r 9 7 ( 0x61) St o p Se n so r M e ssa g e ( r e a d o n l y ) I nt ernal param et er t hat can only be read. Set t ing of t he int ernal param et er causes t he cessat ion of unconfirm ed repet it ive sensor m essages if t he st at e of t he sensor changes. Default : 0x01 ( act ive) Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 135 Ch a p t e r 7 Operation Pa r a m e t e r 9 8 ( 0x62) Er r o r ‘ U n e x p e ct e d ’ ( r e a d o n l y ) I nt ernal param et er t hat can only be read. Set t ing t he int ernal param et er causes error 9 ( unexpect ed) t o be out put only once successively. Default : 0x01 ( act ive) Pa r a m e t e r 9 9 ( 0x63) Fa ct o r y R e se t / Fi n e V e r si o n The reader can be placed in t he default st at us via t his param et er. Only value 0x00 is approved here! However, t he param et er delivers t he fine version of t he soft ware upon a query. Default : 0x00 ( Fine version 0) Pa r a m e t e r 1 0 0 ( 0x64) Gl o b a l ET SI Ch a n n e l Li st This param et er specifies all ETSI channels t o be used when t he global list ( par 0x69 channel swit ching m ode) has t he value 0. The global ETSI channel list can cont ain up t o 16 ent ries. Value range: 0x00 t o 0x0F 0x00 no channel 0x01 … 0x0F ETSI channel 1 ( 865.1 MHz) ETSI channel 15 ( 867.9 MHz) Default : Channels 0x04, 0x07, 0x0A, and 0x0D Pa r a m e t e r 1 0 1 ( 0x65) ET SI Ch a n n e l Li st A n t e n n a 1 This param et er specifies all ETSI channels of ant enna port 1 t o be used. The channel swit ching m ode par 0x69 m ust t hereby have a value of 1 so t hat t he relevant list of t he corresponding ant enna port is used. The ETSI channel list of ant enna port 1 can cont ain up t o 16 ent ries. Value range: 0x00 t o 0x0F 0x00 0x01 0x0F no channel ETSI channel 1 ( 865.1 MHz) ETSI channel 15 ( 867.9 MHz) Default : Channels 0x04, 0x07, 0x0A, and 0x0D Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 136 Ch a p t e r 7 Operation Pa r a m e t e r 1 0 2 ( 0x66) ET SI Ch a n n e l Li st A n t e n n a 2 This param et er specifies all ETSI channels of ant enna port 2 t o be used. The channel swit ching m ode par 0x69 m ust t hereby have a value of 1 so t hat t he relevant list of t he corresponding ant enna port is used. The ETSI channel list of ant enna port 1 can cont ain up t o 16 ent ries. Value range: 0x00 t o 0x0F 0x00 0x01 0x0F no channel ETSI channel 1 ( 865.1 MHz) ETSI channel 15 ( 867.9 MHz) Default : Channels 0x04, 0x07, 0x0A, and 0x0D Pa r a m e t e r 1 0 3 ( 0x67) ET SI Ch a n n e l Li st A n t e n n a 3 This param et er specifies all ETSI channels of ant enna port 3 t o be used. The channel swit ching m ode par 0x69 m ust t hereby have a value of 1 so t hat t he relevant list of t he corresponding ant enna port is used. The ETSI channel list of ant enna port 1 can cont ain up t o 16 ent ries. Value range 0x00 t o 0x0F 0x00 0x01 0x0F no channel ETSI channel 1 ( 865.1 MHz) ETSI channel 15 ( 867.9 MHz) Default : Channels 0x04, 0x07, 0x0A, and 0x0D Pa r a m e t e r 1 0 4 ( 0x68) ET SI Ch a n n e l Li st A n t e n n a 4 This param et er specifies all ETSI channels of ant enna port 4 t o be used. The channel swit ching m ode par 0x69 m ust t hereby have a value of 1 so t hat t he relevant list of t he corresponding ant enna port is used. The ETSI channel list of ant enna port 1 can cont ain up t o 16 ent ries. Value range 0x00 t o 0x0F 0x00 0x01 0x0F no channel ETSI channel 1 ( 865.1 MHz) ETSI channel 15 ( 867.9 MHz) Default : Channels 0x04, 0x07, 0x0A, and 0x0D Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 137 Ch a p t e r 7 Operation Pa r a m e t e r 1 0 5 ( 0x69) Ch a n n e l Sw i t ch i n g M o d e This param et er defines if t he global ETSI channel list is used or if each port has it s own channel list . Value range: 0x00 t o 0x01 0x00 0x01 Use global ETSI channel list Use t he ETSI channel list of t he respect ive ant enna port Default : 0x00 Pa r a m e t e r 1 0 6 ( 0 x 6 A) T r a n sm i ssi o n O u t p u t A n t e n n a P o r t 1 This value defines t he t ransm ission out put of ant enna port 1. Value range: 0x00 ( 0 dBm ) The port is disabled. 0x44 t o 0x84 ( 17 dBm t o 33 dBm ; increm ent 0.25 dBm ) Default : 0x6C ( 27 dBm ) Pa r a m e t e r 1 0 7 ( 0 x 6 B) T r a n sm i ssi o n O u t p u t A n t e n n a P o r t 2 This value defines t he t ransm ission out put of ant enna port 2. Value range: 0x00 ( 0 dBm ) The port is disabled. 0x44 t o 0x84 ( 17 dBm t o 33 dBm ; increm ent 0.25 dBm ) Default : 0x00 ( 0 dBm ) Pa r a m e t e r 1 0 8 ( 0 x 6 C) T r a n sm i ssi o n O u t p u t A n t e n n a P o r t 3 This value defines t he t ransm ission out put of ant enna port 3. Value range: 0x00 ( 0 dBm ) The port is disabled. 0x44 t o 0x84 ( 17 dBm t o 33 dBm ; increm ent 0.25 dBm ) Default : 0x00 ( 0 dBm ) Pa r a m e t e r 1 0 9 ( 0x6D) T r a n sm i ssi o n O u t p u t A n t e n n a P o r t 4 This value defines t he t ransm ission out put of ant enna port 4. Value range: 0x00 ( 0 dBm ) The port is disabled. 0x44 t o 0x84 ( 17 dBm t o 33 dBm ; increm ent 0.25 dBm ) Default : 0x00 ( 0 dBm ) Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 138 Ch a p t e r 7 Operation Pa r a m e t e r 1 1 0 ( 0 x 6 E) A n t e n n a ca b l e p o r t 1 a t t e n u a t i o n This value defines t he at t enuat ion of t he ant enna cable at port 1. Value range: 0x00 t o 0xFF ( 0 dB t o 63.75 dB; increm ent 0.25 dB) Default : 0x00 ( 0 dB) Pa r a m e t e r 1 1 1 ( 0 x 6 F) A n t e n n a ca b l e p o r t 2 a t t e n u a t i o n This value defines t he at t enuat ion of ant enna cable at port 2. Value range: 0x00 t o 0xFF ( 0 dB t o 63.75 dB; increm ent 0.25 dB) Default : 0x00 ( 0 dB) Pa r a m e t e r 1 1 2 ( 0x70) A n t e n n a ca b l e p o r t 3 a t t e n u a t i o n This value defines t he at t enuat ion of t he ant enna cable at port 3. Value range: 0x00 t o 0xFF ( 0 dB t o 63.75 dB; increm ent 0.25 dB) Default : 0x00 ( 0 dB) Pa r a m e t e r 1 1 3 ( 0x71) A n t e n n a ca b l e p o r t 4 a t t e n u a t i o n This value defines t he at t enuat ion of ant enna cable at port 4. Value range: 0x00 t o 0xFF ( 0 dB t o 63.75 dB; increm ent 0.25 dB) Default : 0x00 ( 0 dB) Pa r a m e t e r 1 1 4 ( 0x72) An t e n n a g a in p or t 1 This value defines t he ant enna gain of t he ant enna connect ed t o port 1. Value range: - 128 t o 127 ( - 32 dB t o 31.75 dB; increm ent 0.25 dB) Default : 0x14 ( 5 dB) Pa r a m e t e r 1 1 5 ( 0x73) An t e n n a g a in p or t 2 This value defines t he ant enna gain of t he ant enna connect ed t o port 2. Value range: - 128 t o 127 ( - 32 dB t o 31.75 dB; increm ent 0.25 dB) Default : 0x14 ( 5 dB) Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 139 Ch a p t e r 7 Operation Pa r a m e t e r 1 1 6 ( 0x74) An t e n n a g a in p or t 3 This value defines t he ant enna gain of t he ant enna connect ed t o port 3. Value range: - 128 t o 127 ( - 32 dB t o 31.75 dB; increm ent 0.25 dB) Default : 0x14 ( 5 dB) Pa r a m e t e r 1 1 7 ( 0x75) An t e n n a g a in p or t 4 This value defines t he ant enna gain of t he ant enna connect ed t o port 4. Value range: - 128 t o 127 ( - 32 dB t o 31.75 dB; increm ent 0.25 dB) Default : 0x14 ( 5 dB) Pa r a m e t e r 1 1 8 ( 0x76) Ex t e n d e d R e su l t Fl a g This value defines t he dat a of a det ect ed t ransponder t hat are also displayed. Value range: see inform at ion unit " Ex flag" and " Ext ensions" in Message it em s Default : 0x01 ( ant enna port only) Pa r a m e t e r 1 1 9 ( 0x77) Gl i m p se d T i m e o u t Co u n t Num ber of unsuccessful invent ories unt il a t ransponder t hat was previously det ect ed was rem oved from t he t ransponder list . Value range: 0x00 t o 0xFF Default : 0x03 Pa r a m e t e r 1 2 0 ( 0x78) O b se r v e d T h r e sh o l d Co u n t Num ber of successful t ransponders before it elevat ed int o t he " observed" st at us ( generat ing of " incom ing" m essage) . Value range: 0x00 t o 0xFF Default : 0x05 Pa r a m e t e r 1 2 1 ( 0x79) O b se r v e d T i m e o u t Co u n t Num ber of unsuccessful invent ories unt il an " observed" t ransponder looses t he " observed" st at us ( generat ing an " out going" m essage) . Value range: 0x00 t o 0xFF Default : 0x05 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 140 Ch a p t e r 7 Operation Pa r a m e t e r 1 2 2 ( 0 x 7 A) Co m m u n i ca t i o n s st a n d a r d The com m unicat ions st andard is select ed by t his param et er ( as far as possible and enabled by t he license) . Value range: 0x00 t o 0x07 0x00: 0x01: 0x02: 0x03: 0x04: 0x05: 0x06: 0x07: No com m unicat ions st andard Aut o det ect EN302208 EN302208_LBT FCC Own special set t ings China Thailand Default : 0x01 Pa r a m e t e r 1 2 3 ( 0 x 7 B) ET SI P o w e r Ch e ck O v e r A l l A l l o w e d Ch a n n e l s Wit h t his param et er, t he perform ance check is conduct ed via t he set channels. Value range: 0x00 ( false) and 0xFF ( t rue) Default : 0x00 ( false) Pa r a m e t e r 1 2 4 ( 0 x 7 C) Co m m St a n d a r d Ce n t e r Fr e q CH 0 Param et ers for t he com m unicat ions st andard " specific" . Mid- frequency channel 0 in kHz Value range: 0 t o 1,048,575 kHz Default : 0x00000000 Pa r a m e t e r 1 2 5 ( 0x7D) Co m m St a n d a r d Ch a n n e l W i d t h Param et ers for t he com m unicat ions st andard " specific" . Channel widt h in kHz Value range: 0 t o 65,535 kHz Default : 0x0000 Pa r a m e t e r 1 2 6 ( 0 x 7 E) Co m m St a n d a r d M a x Ch a n n e l T i m e Param et ers for t he com m unicat ions st andard " specific" . Maxim um channel dwell t im e in m s Value range: 10 t o 65,535 m s Default : 0x0000 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 141 Ch a p t e r 7 Operation Pa r a m e t e r 1 2 7 ( 0 x 7 F) Co m m St a n d a r d M i n Ch a n n e l W a i t T i m e Param et ers for t he com m unicat ions st andard " specific" . Channel widt h in kHz Value range: 0 t o 65,535 kHz Default : 0x0000 Pa r a m e t e r 1 2 8 ( 0x80) Co m m St a n d a r d Fi r st Ch a n n e l Param et ers for t he com m unicat ions st andard " specific" . Num ber of t he first channel Value range: 0 t o 255 Default : 0x00 Pa r a m e t e r 1 2 9 ( 0x81) Co m m St a n d a r d La st Ch a n n e l Param et ers for t he com m unicat ions st andard " specific" . Num ber of t he last channel Value range: 0 t o 255 Default : 0x00 Pa r a m e t e r 1 3 0 ( 0x82) T a g Co m m I n t e l l i g e n t W r i t e Only t he changing dat a are writ t en again during int elligent writ ing. Value range: 0x00 ( false) and 0xFF ( t rue) Default : 0xFF ( t rue) Pa r a m e t e r 1 3 1 ( 0x83) T a g Co m m V e r i f y W r i t e Writ t en dat a are verified again by t he cont rol reading. Value range: 0x00 ( false) and 0xFF ( t rue) Default : 0xFF ( t rue) Pa r a m e t e r 1 3 2 ( 0x84) T a g Co m m Q u e r y T a r g e t Only t ransponders wit h a corresponding invent oried flag ( A or B) part icipat e in t he invent ory round. A det ailed descript ion of t he param et er is locat ed in t he EPC global specificat ion for t he query com m and. Value range: 0x00 ( t arget A) and 0x01 ( t arget B) Default : 0x00 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 142 Ch a p t e r 7 Operation Pa r a m e t e r 1 3 3 ( 0x85) T a g Co m m Q u e r y Se l Defines t he t ransponders t hat part icipat e in t he query com m and. A det ailed descript ion of t he param et er is locat ed in t he EPC global specificat ion for t he query com m and. Value range: 0x00 t o 0x03 Default : 0x00 ( t rue) Pa r a m e t e r 1 3 4 ( 0x86) H o st Co m m A n t e n n a I n d e p e n d e n d O p e r a t i o n Ant ennas independent reading, i.e. for each t ransponder t here is only one ent ry in t he observed list , even if it was read at different ant ennas. Value range: 0x00 ( false) or 0xFF ( t rue) Default : 0x00 Pa r a m e t e r 1 3 5 ( 0x87) R F I n t e r f a ce T i m e t o P o w e r O f f The carrier follow- up t im e indicat es how long t he carrier rem ains on aft er a t ransponder operat ion ( subj ect t o t he rest rict ions of t he select ed com m unicat ions st andard) . Value range: 0 t o 65,535 s Default : 0x0005 ( 5 s) Pa r a m e t e r 1 3 6 ( 0x88) R F I n t e r f a ce M o d u l a t i o n T y p e Modulat ion t ype Value range: 0 ( DSB) and 1 ( PR-ASK) Default : 0x01 ( PR- ASK) Pa r a m e t e r 1 3 7 ( 0x89) R F I n t e r f a ce M u l t i p l e x i n g A n t e n n a P o r t 1 First list ent ry of t he ant enna port list ! The m ult iplexing ant enna port list specifies t he order of t he ant enna port s for a m ult iple ant enna invent ory. The dwell t im e of t he invent ory corresponding wit h t he list ent ry is defined lat er by t he param et er " I nt erface Mult iplexing Exposure Tim e 1" . Value range: 0x00 no ant enna port 0x01 t o 0x04 for t he respect ive ant enna port Default : 0x01 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 143 Ch a p t e r 7 Operation Pa r a m e t e r 1 3 8 ( 0 x 8 A) R F I n t e r f a ce M u l t i p l e x i n g A n t e n n a P o r t 2 Second list ent ry of t he ant enna port list ! The m ult iplexing ant enna port list specifies t he order of t he ant enna port s for a m ult iple ant enna invent ory. The dwell t im e of t he invent ory corresponding wit h t he list ent ry is defined lat er by t he param et er " I nt erface Mult iplexing Exposure Tim e 2" . Value range: 0x00 no ant enna port 0x01 t o 0x04 for t he respect ive ant enna port Default : 0x02 Pa r a m e t e r 1 3 9 ( 0 x 8 B) R F I n t e r f a ce M u l t i p l e x i n g A n t e n n a P o r t 3 Third list ent ry of t he ant enna port list ! The m ult iplexing ant enna port list specifies t he order of t he ant enna port s for a m ult iple ant enna invent ory. The dwell t im e of t he invent ory corresponding wit h t he list ent ry is defined lat er by param et er " I nt erface Mult iplexing Exposure Tim e 3" . Value range: 0x00 no ant enna port 0x01 t o 0x04 for t he respect ive ant enna port Default : 0x03 Pa r a m e t e r 1 4 0 ( 0 x 8 C) R F I n t e r f a ce M u l t i p l e x i n g A n t e n n a P o r t 4 Fourt h list ent ry of t he ant enna port list ! The m ult iplexing ant enna port list specifies t he order of t he ant enna port s for a m ult iple ant enna invent ory. The dwell t im e of t he invent ory corresponding wit h t he list ent ry is defined lat er by param et er " I nt erface Mult iplexing Exposure Tim e 4" . Value range: 0x00 no ant enna port 0x01 t o 0x04 for t he respect ive ant enna port Default : 0x04 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 144 Ch a p t e r 7 Operation Pa r a m e t e r 1 4 1 ( 0x8D) R F I n t e r f a ce M u l t i p l e x i n g A n t e n n a P o r t 5 Fift h list ent ry of t he ant enna port list ! The m ult iplexing ant enna port list specifies t he order of t he ant enna port s for a m ult iple ant enna invent ory. The dwell t im e of t he invent ory corresponding wit h t he list ent ry is defined lat er by param et er " I nt erface Mult iplexing Exposure Tim e 5" . Value range: 0x00 no ant enna port 0x01 t o 0x04 for t he respect ive ant enna port Default : 0x00 Pa r a m e t e r 1 4 2 ( 0 x 8 E) R F I n t e r f a ce M u l t i p l e x i n g A n t e n n a P o r t 6 Sixt h list ent ry of t he ant enna port list ! The m ult iplexing ant enna port list specifies t he order of t he ant enna port s for a m ult iple ant enna invent ory. The dwell t im e of t he invent ory corresponding wit h t he list ent ry is defined lat er by param et er " I nt erface Mult iplexing Exposure Tim e 6" . Value range: 0x00 no ant enna port 0x01 t o 0x04 for t he respect ive ant enna port Default : 0x00 Pa r a m e t e r 1 4 3 ( 0 x 8 F) R F I n t e r f a ce M u l t i p l e x i n g A n t e n n a P o r t 7 Sevent h list ent ry of t he ant enna port list ! The m ult iplexing ant enna port list specifies t he order of t he ant enna port s for a m ult iple ant enna invent ory. The dwell t im e of t he invent ory corresponding wit h t he list ent ry is defined lat er by param et er " I nt erface Mult iplexing Exposure Tim e 7" . Value range: 0x00 no ant enna port 0x01 t o 0x04 for t he respect ive ant enna port Default : 0x00 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 145 Ch a p t e r 7 Operation Pa r a m e t e r 1 4 4 ( 0x90) R F I n t e r f a ce M u l t i p l e x i n g A n t e n n a P o r t 8 Eight h list ent ry of t he ant enna port list ! The m ult iplexing ant enna port list specifies t he order of t he ant enna port s for a m ult iple ant enna invent ory. The dwell t im e of t he invent ory corresponding wit h t he list ent ry is defined lat er by param et er " I nt erface Mult iplexing Exposure Tim e 8" . Value range: 0x00 no ant enna port 0x01 t o 0x04 for t he respect ive ant enna port Default : 0x00 Pa r a m e t e r 1 4 5 ( 0x91) R F I n t e r f a ce R SSI T h r e sh o l d 1 RSSI t hreshold value at port 1 m ust be reached so t hat t he respect ive EPC t ransponder is displayed. Value range: 0x00 t o 0xFF Default : 0x00 Pa r a m e t e r 1 4 6 ( 0x92) R F I n t e r f a ce R SSI T h r e sh o l d 2 RSSI t hreshold value at port 2 m ust be reached so t hat t he respect ive EPC t ransponder is displayed. Value range: 0x00 t o 0xFF Default : 0x00 Pa r a m e t e r 1 4 7 ( 0x93) R F I n t e r f a ce R SSI T h r e sh o l d 3 RSSI t hreshold value at port 3 m ust be reached so t hat t he respect ive EPC t ransponder is displayed. Value range: 0x00 t o 0xFF Default : 0x00 Pa r a m e t e r 1 4 8 ( 0x94) R F I n t e r f a ce R SSI T h r e sh o l d 4 RSSI t hreshold value at port 4 m ust be reached so t hat t he respect ive EPC t ransponder is displayed. Value range: 0x00 t o 0xFF Default : 0x00 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 146 Ch a p t e r 7 Operation Pa r a m e t e r 1 4 9 ( 0x95) R F I n t e r f a ce M u l t i p o w e r T a g A cce ss 1 Variat ion of t he power at ant enna port 1 in order e.g. t o det ect EPC t ransponders in t he im m ediat e ant enna vicinit y bet t er. Value range: 0x00 ( disabled) t o 0xFF ( enabled) Default : 0xFF Pa r a m e t e r 1 5 0 ( 0x96) R F I n t e r f a ce M u l t i p o w e r T a g A cce ss 2 Variat ion of t he power at ant enna port 2 in order e.g. t o det ect EPC t ransponders in t he im m ediat e ant enna vicinit y bet t er. Value range: 0x00 ( disabled) t o 0xFF ( enabled) Default : 0xFF Pa r a m e t e r 1 5 1 ( 0x97) R F I n t e r f a ce M u l t i p o w e r T a g A cce ss 3 Variat ion of t he power at ant enna port 3 in order e.g. t o det ect EPC t ransponders in t he im m ediat e ant enna vicinit y bet t er. Value range: 0x00 ( disabled) t o 0xFF ( enabled) Default : 0xFF Pa r a m e t e r 1 5 2 ( 0x98) R F I n t e r f a ce M u l t i p o w e r T a g A cce ss 4 Variat ion of t he power at ant enna port 4 in order e.g. t o det ect EPC t ransponders in t he im m ediat e ant enna vicinit y bet t er. Value range: 0x00 ( disabled) t o 0xFF ( enabled) Default : 0xFF Pa r a m e t e r 1 5 3 ( 0x99) R F I n t e r f a ce M a x A l l o w e d A n t e n n a O u t p u t P o w e r 1 The reader lim it s t he power at ant enna port 1 t o t he here defined m axim um ant enna out put power. Value range: 0x00 ( 0 dBm ( erp) ) t o 0xFF ( 63.75 dBm ( erp) ) Default : 0x84 ( 33 dBm ( erp) ) Pa r a m e t e r 1 5 4 ( 0 x 9 A) R F I n t e r f a ce M a x A l l o w e d A n t e n n a O u t p u t P o w e r 2 The reader lim it s t he power at ant enna port 2 t o t he here defined m axim um ant enna out put power. Value range: 0x00 ( 0 dBm ( erp) ) t o 0xFF ( 63.75 dBm ( erp) ) Default : 0x84 ( 33 dBm ( erp) ) Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 147 Ch a p t e r 7 Operation Pa r a m e t e r 1 5 5 ( 0 x 9 B) R F I n t e r f a ce M a x A l l o w e d A n t e n n a O u t p u t P o w e r 3 The reader lim it s t he power at ant enna port 3 t o t he here defined m axim um ant enna out put power. Value range: 0x00 ( 0 dBm ( erp) ) t o 0xFF ( 63.75 dBm ( erp) ) Default : 0x84 ( 33 dBm ( erp) ) Pa r a m e t e r 1 5 6 ( 0 x 9 C) R F I n t e r f a ce M a x A l l o w e d A n t e n n a O u t p u t P o w e r 4 The reader lim it s t he power at ant enna port 4 t o t he here defined m axim um ant enna out put power. Value range: 0x00 ( 0 dBm ( erp) ) t o 0xFF ( 63.75 dBm ( erp) ) Default : 0x84 ( 33 dBm ( erp) ) Pa r a m e t e r 1 5 7 ( 0x9D) T a g Co m m U se P i l o t T o n e Transponder pilot t one on and off. Value range: 0x00 ( off ) or 0xFF ( on) Default : 0xFF Pa r a m e t e r 1 5 8 ( 0 x 9 E) T a g Co m m I n i t i a l Q The init ial Q result s from t he num ber of ant icipat ed t ransponders ( ant icipat ed t ransponder num ber = 2Q) . Value range: 0x00 t o 0x0F Default : 0x03 Pa r a m e t e r 1 5 9 ( 0 x 9 F) T a g Co m m Se ssi o n Defines t he t ransponder session t o be applied ( see Gen2 EPCglobal St andard) . Value range: 0x00 t o 0x03 Default : 0x02 Pa r a m e t e r 1 6 0 ( 0 x A0 ) T a g Co m m M a x Er r o r s Num ber of repeat at t em pt s of an air int erface com m and when an ant icipat ed com m and response rem ains pending. Value range: 0x00 t o 0xFF Default : 0x05 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 148 Ch a p t e r 7 Operation Pa r a m e t e r 1 6 1 ( 0 x A1 ) T a g Co m m D e f a u l t P r o f i l e A com m unicat ion profile includes t ransm ission dat a rat e, recept ion dat a rat e and t ransponder response encoding ( FM0, Miller 2, Miller 4, Miller 8) in m eaningful and st andard- conform ing com binat ions. The list of support ed profiles is available wit h t he UGL com m and. Value range: 0x00 t o 0xFF Default : 0x04 Pa r a m e t e r 1 6 2 ( 0 x A2 ) R F I n t e r f a ce M u l t i p l e x i n g Ex p o su r e T i m e 1 Dwell t im e on t he ant enna port , which is defined as t he first list ent ry of t he m ult iplexing ant enna port list ( par. RF I nt erface Mult iplexing Ant enna Port 1) . The dwell t im e indicat es how long an invent ory is perform ed on an ant enna port ( only for polling act ions) . Value range: 0 t o 65,535 in m s Default : 100 m s Pa r a m e t e r 1 6 3 ( 0 x A3 ) R F I n t e r f a ce M u l t i p l e x i n g Ex p o su r e T i m e 2 Dwell t im e on t he ant enna port , which is defined as t he first list ent ry of t he m ult iplexing ant enna port list ( par. RF I nt erface Mult iplexing Ant enna Port 2) . The dwell t im e indicat es how long an invent ory is perform ed on an ant enna port ( only for polling act ions) . Value range: 0 t o 65,535 in m s Default : 100 m s Pa r a m e t e r 1 6 4 ( 0 x A4 ) R F I n t e r f a ce M u l t i p l e x i n g Ex p o su r e T i m e 3 Dwell t im e on t he ant enna port , which is defined as t he first list ent ry of t he m ult iplexing ant enna port list ( par. RF I nt erface Mult iplexing Ant enna Port 3) . The dwell t im e indicat es how long an invent ory is perform ed on an ant enna port ( only for polling act ions) . Value range: 0 t o 65,535 in m s Default : 100 m s Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 149 Ch a p t e r 7 Operation Pa r a m e t e r 1 6 5 ( 0 x A5 ) R F I n t e r f a ce M u l t i p l e x i n g Ex p o su r e T i m e 4 Dwell t im e on t he ant enna port , which is defined as t he first list ent ry of t he m ult iplexing ant enna port list ( par. RF I nt erface Mult iplexing Ant enna Port 4) . The dwell t im e indicat es how long an invent ory is perform ed on an ant enna port ( only for polling act ions) . Value range: 0 t o 65,535 in m s Default : 100 m s Pa r a m e t e r 1 6 6 ( 0 x A6 ) R F I n t e r f a ce M u l t i p l e x i n g Ex p o su r e T i m e 5 Dwell t im e on t he ant enna port , which is defined as t he first list ent ry of t he m ult iplexing ant enna port list ( par. RF I nt erface Mult iplexing Ant enna Port 5) . The dwell t im e indicat es how long an invent ory is perform ed on an ant enna port ( only for polling act ions) . Value range: 0 t o 65,535 in m s Default : 100 m s Pa r a m e t e r 1 6 7 ( 0 x A7 ) R F I n t e r f a ce M u l t i p l e x i n g Ex p o su r e T i m e 6 Dwell t im e on t he ant enna port , which is defined as t he first list ent ry of t he m ult iplexing ant enna port list ( par. RF I nt erface Mult iplexing Ant enna Port 6) . The dwell t im e indicat es how long an invent ory is perform ed on an ant enna port ( only for polling act ions) . Value range: 0 t o 65,535 in m s Default : 100 m s Pa r a m e t e r 1 6 8 ( 0 x A8 ) R F I n t e r f a ce M u l t i p l e x i n g Ex p o su r e T i m e 7 Dwell t im e on t he ant enna port , which is defined as t he first list ent ry of t he m ult iplexing ant enna port list ( par. RF I nt erface Mult iplexing Ant enna Port 7) . The dwell t im e indicat es how long an invent ory is perform ed on an ant enna port ( only for polling act ions) . Value range: 0 t o 65,535 in m s Default : 100 m s Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 150 Ch a p t e r 7 Operation Pa r a m e t e r 1 6 9 ( 0 x A9 ) R F I n t e r f a ce M u l t i p l e x i n g Ex p o su r e T i m e 8 Dwell t im e on t he ant enna port , which is defined as t he first list ent ry of t he m ult iplexing ant enna port list ( par. RF I nt erface Mult iplexing Ant enna Port 8) . The dwell t im e indicat es how long an invent ory is perform ed on an ant enna port ( only for polling act ions) . Value range: 0 t o 65,535 in m s Default : 100 m s Pa r a m e t e r 1 7 0 ( 0 x AA) R F I n t e r f a ce En a b l e R SSI T h r e sh o l d A t Sp e ci f i c Cm d s Act ivat es or deact ivat es RSSI t hreshold check for t he specific com m ands URY, UWZ, UMZ, UBZ, ULZ and UKZ. Value range: 0; 255 Default : 0xFF ( act ive) Pa r a m e t e r 1 7 1 ( 0 x A B) R F I n t e r f a ce Fl a sh W r i t e Ad d i t i o n a l P o w e r The t ransponder requires m ore power for writ ing t han for reading. Therefore it needs t o be closer t o t he ant enna when writ ing. I f writ ing errors occur ( Writ e, Lock, Kill,...) t he t ransm ission out put can be increased in st eps of 1/ 4 dB wit h t he I nt erface Flash Writ e Addit ional Power param et er in order t o bridge t he gap bet ween reading and writ ing dist ance. Value range: 0 - 48 Default : 0x00 Pa r a m e t e r 1 7 2 ( 0 x A C) T a g Co m m Fo r ce P o w e r O f f A f t e r EP C W r i t e When writ ing t he EPC code, t he checksum of t he t ransponder is changed. Therefore t he t ransponder can not t ake part in t he next invent ory. Only by swit ching t he ant enna field off and on will t he t ransponder be react ivat ed and can t ake part in t he invent ory process again. The param et er specifies t he t im e in 1 m s st eps how long t he UHF carrier is swit ched off aft er an EPC writ ing. Value range: 0 - 255 in m s Default : 0x00 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 151 Ch a p t e r 7 Operation Pa r a m e t e r 1 7 3 ( 0 x AD ) T a g Co m m T r a n sm i t Ge t EP Cs P r e Se l e ct This param et er only affect s t he com m ands M, URM, URB, UAA and UAM. All ot her com m ands behave as if t he param et er was zero. Pa r a m e t e r is ze r o: 1. The first ant enna is chosen from t he m ult iplex list . 2. All t ransponders wit hin receiving range are reset by a Select . 3. An invent ory is conduct ed unt il no furt her t ransponders can be found. 4. I f t he m ult iplex list cont ains addit ional ant ennas, t he st eps are repeat ed for each of t hese ant ennas. 5. The com m and is finished and t he result is t ransferred t o t he upper level. Pa r a m e t e r is n on - ze r o: 1. The first ant enna is chosen from t he m ult iplex list . 2. All t ransponders wit hin receiving range are reset by a Select . 3. I f t he m ult iplex list cont ains addit ional ant ennas, t his st ep is repeat ed for each of t hese ant ennas. 4. The first ant enna of t his list is chosen again and an invent ory is conduct ed unt il no furt her t ransponders can be found. 5. This st ep is repeat ed for each ant enna of t he m ult iplex list . 6. The com m and is finished and t he result is t ransferred t o t he upper level. This param et er reduces t he t im e for a com prehensive det ect ion of a group of t ransponders if t his group is wit hin receiving range of t he ant enna, and it is not im port ant which ant enna det ect s which t ransponder. I f during t his process a t ransponder is det ect ed by an ant enna, t his t ransponder will not be processed by t he subsequent ant ennas. Value range: 0; 255 Default : 0x00 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 152 Ch a p t e r 7 Operation Pa r a m e t e r 1 7 4 ( 0 x A E) T a g Co m m T r a n sm i t Se l e ct I f N o Fi l t e r I s O n Wit h a Select filt er or Select com m and at t he beginning of an invent ory, t he reader set s all t ransponders wit hin t he range of t he ant enna t o a defined out put st at e. The t ransponders will be det ect ed in an addit ional invent ory. I f no Select filt er is defined, a Select com m and can be displayed via t his param et er. All t ransponders wit hin ant enna reach can be reset wit h t his com m and. Value range: 0; 255 Default : 0x00 Pa r a m e t e r 1 7 5 ( 0 x A F) T a g Co m m N u m b e r O f EP C W o r d s The UF70 Cert um reader can read t ransponders wit h an EPC lengt h from 0 t o 31 words ( 0 t o 496 Bit EPCs) . This param et er can deact ivat e t he aut om at ic det ect ion of t he EPC lengt h. The reader t herefore reads t ransponders wit h a fixed lengt h. Value range: 0 - 31; 255 Default : 0xFF Pa r a m e t e r 1 7 6 ( 0 x B0 ) T a g Co m m U se Bl o ck W r i t e Wit h t his param et er, t he " BlockWrit e" com m and is act ivat ed during t he writ ing of dat a on a t ransponder. The reader t hen writ es m ore t han 16 Bit ( one word) on t he t ransponder wit h only one com m and. I M PORTAN T Not all t ransponders support t he " BlockWrit e" com m and. The inform at ion if t he respect ive t ransponder support s t his com m and can be read in t he corresponding dat a sheet s. Value range: 0; 255 Default : 0x00 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 153 Ch a p t e r 7 Operation Pa r a m e t e r 1 7 7 ( 0 x B1 ) T a g Co m m D i sa b l e R e ce i v i n g N X P R e a d P r o t e ct e d T a g s A t ransponder prot ect ed wit h " ReadProt ect " of NXP does not t ransm it an EPC and a valid checksum during an invent ory. The dat a cont ent of EPC and checksum is zero. For t he reader t o be able t o det ect t hese t ransponders, it let s pass t ransponders wit h EPC and checksum zero. These t ransponders are no longer prot ect ed by a valid checksum . I n order t o avoid t he reader det ect ing t ransponders t hat are not present , t his param et er should be act ivat ed. Wit h t his, t he recept ion of " ReadProt ect " prot ect ed t ransponders is prevent ed. Value range: 0; 255 Default : 0x00 Pa r a m e t e r 1 7 8 ( 0 x B2 ) H o st Co m m A Sy n c Ad d i t i o n a l R SSI D a t a D e l i v e r y D e l t a This param et er influences t he behavior of all asynchronous com m ands ( act ivat e polling UAN com m and) except t he UAA com m and. At asynchronous com m ands ( act ivat e polling) an " incom ing" m essage is generat ed and t ransferred t o t he upper level if a t ransponder ent ers t he ant enna range. I f a t ransponder leaves t he ant enna range, an " out going" m essage is generat ed. I n order t o be able t o follow t he m ovem ent s of a t ransponder wit hin t he ant enna range, t he field int ensit y ( RSSI value) of a t ransponder bet ween " incom ing" and " out going" m essages has t o be observed. This param et er indicat es how t he field int ensit y of a t ransponder needs t o change for a " TransponderDat aChanged" m essage t o be generat ed and be t ransferred t o t he upper level. No m essages are generat ed at an RSSI value of 255. I M PORTAN T The Param et er Ext ended Result flag ( see Param et er 118 ( 0x76) ) has t o be set in a way t hat t he RSSI value is part of t he " TransponderDat aChanged" m essage. Value range: 0 - 255 Default : 0xFF Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 154 Ch a p t e r 7 Operation Pa r a m e t e r 1 7 9 ( 0 x B3 ) H o st Co m m U se M i l l i se co n d s A s T i m e st a m p I n addit ion t o t he t ransponder dat a, a t im e st am p can also be t ransferred t o t he upper level aft er an ivent ory ( see param et er 118) . This param et er det erm ines if t his t im e st am p cont ains t he t im e passed in m s since t he st art of t he reader or t he UTC t im e in s since 01.01.1970 0: 00: 00. I f t his param et er is act ivat ed, t he t im e passed in m s since t he st art of t he reader is t ransferred as a t im e st am p. Value range: 0; 255 Default : 0x00 7 .3 I M PORTAN T Addit ion a l in for m a t ion Never expose t he device t o ext rem e t em perat ure fluct uat ions, since condensat ion ot herwise develops in t he device and causes dam age! Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 155 Ch a p t e r 8 Se r vice a nd Tr ouble shoot ing Se r v ice a n d Tr o u b le sh o o t in g This chapt er gives you an overview of t he following t opics: ■ General rem arks ■ Qualified t roubleshoot ing personnel ■ Safet y inst ruct ions ■ Error codes ■ Error display wit h LED ■ Reader does not respond ■ Reset ■ Power cut ■ Soft ware releases ■ Cust om er service 8 .1 Ge n e r a l r e m a r k s H e a d t h e sa f e t y ch a p t e r Follow t he general safet y inst ruct ions in t he chapt er Safet y I nst ruct ions. The t ransponder reader and it s com ponent s m ust be serviced by t he m anufact urer only! I f errors occur, follow t he inst ruct ions in t his sect ion. Do not carry out any error- elim inat ing m easures ot her t han t he ones described in t his sect ion! I f you are uncert ain about errors and t heir handling, cont act t he m anufact urer; see Cust om er service. Have t he serial num ber of t he t ransponder reader ready as shown on t he label ( see Device label) ! Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 156 Ch a p t e r 8 Se r vice a nd Tr ouble shoot ing 8 .2 CAUTI ON Qu a lif ie d t r ou b le sh oo t in g p e r son n e l Error handling m ust only be carried out by specially t rained personnel. I f you are uncert ain about t he qualificat ions t hat are required, cont act t he m anufact urer. CAUTI ON Error handling t he device wit hout t he special skills required and unqualified int erference wit h t he device can result in personal inj ury and dam age t o t he reader and/ or connect ed devices. nbb 8 .3 Sa f e t y in st r u ct io n s All ant enna resonant circuit com ponent s carry high volt ages! W ARN I N G When replacem ent part s are required, use only m anufact urer- specified part s. Unaut horized subst it ut ion of part s can result in fire, elect ric shock or ot her hazards. Elect rost at ic charges can dam age elect ronic com ponent s wit hin t he device. ESD prot ect ive m easures m ust be applied when opening t he device ( ESD inst ruct ions) . CAUTI ON When rem oving t he cover, consider t hat t he cover m ay be at t ached t o t he device by a cable ( LED) . Carefully rem ove t he cover t o prevent dam ages. Do not operat e t he device when t he cover is open! CAUTI ON Never short circuit t he fuse! This m ay result in fire or dam age on t he device. Only use fuses specified by t he m anufact urer. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 157 Ch a p t e r 8 Se r vice a nd Tr ouble shoot ing 8 .4 Er r o r co d e s Er r o r ID Nam e D e scr i p t i o n P o ssi b l e ca u se s Co r r e ct i n g a ct i o n none no error not used no aut o fail aut om at ic reading is not possible 1) reader is st ill busy wit h a form er read or writ e request wait unt il t he form er request is done read or writ e init iat ed from t he host , and/ or ot her act ions cannot be reader is st ill busy wit h a form er read or writ e request wait unt il t he form er request is done reader is st ill busy wit h a form er read or writ e request wait unt il t he form er request is done no readable t ag at t he reading range bring a t ag int o t he range of t he ant enna; verify t ype and funct ion of t he t ag ant enna is not connect ed correct ly check connect ion of t he ant enna bad orient at ion bet ween ant enna and t ag check orient at ion bet ween ant enna and t ag ( see sect ion ant enna inst allat ion and ant ennas) ant enna is not t uned perform an ant enna t uning ( see sect ion inst allat ion - > DI P swit ches) disrupt ing field at t ransm it t ing freqency check surronding of ant enna for possible disrupt ing sources ( m onit ors , servo m ot ors...) ant enna is dam aged or t oo close t o m et al replace ant enna, verify ant enna inst allat ion dat a sent wit h a com m and are wrong check synt ax and dat a of com m and sent param et er is not im plem ent ed or out of range check synt ax and value of param et er ex fail carried out 1) writ e fail dat a t ransfer t o t he t ag not no t ag invalid possible 1) no t ag or ant enna inst alled invalid param et er or dat a Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 158 Ch a p t e r 8 Se r vice a nd Tr ouble shoot ing Er r o r ID Nam e D e scr i p t i o n P o ssi b l e ca u se s Co r r e ct i n g a ct i o n unknown unknown error not used no unconfig t he device is not configured wrong reader address was sent check synt ax of m essage, check param et er F "Reader address" check parit y and/ or checksum error wrong baud rat e is set check baud rat e of serial int erface ( COM port ) t ransm ision errors on serial com m unicat ion check RS232 cable and connect ors; check disrupt ing sources at RS232 double or wrong acknowledgem ent check host com m unicat ion set t ings serial com m unicat ion is int erupt ed check RS232 cable and connect ors; check disrupt ing sources at RS232 void ackn no valid acknowledge ( unexpect ed acknowledge) locked locked page cannot be writ t en page t o be writ t en is locked ( writ e prot ect ed forever) check page num ber t o writ e; replace t ag wit h new one m sg len m essage t oo long or t oo short , or m essage is not received in full lengt h of m essage is longer t han shown at t he lengt h byt e check m essage lengt h, check lengt h byt e no valid end sign of m essage ( End sign 0x0D) det ect ed check synt ax of m essage not all charact ers are t ransm it t ed ( I nt ercharact er t im eout ) check synt ax of m essage, check RS232 connect ion unknown com m and was sent check synt ax of com m and invalid invalid com m and Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 159 Ch a p t e r 8 Se r vice a nd Tr ouble shoot ing Er r o r ID Nam e D e scr i p t i o n P o ssi b l e ca u se s Co r r e ct i n g a ct i o n no ackn t he m essage which has t o be confirm ed has been sent t he m axim um num ber of t im es ( rs232 m axrepeat ) , and has not been confirm ed by t he t erm inal wit hin t he defined t im e fram e ( see param et er 5) Host syst em does not acknowledge t he m essage check availabilit y of host syst em ( t erm inal) ; check RS232 cables and connect ors 1) because t he device is st ill busy or because a m essage has not been confirm ed by t he previous read up t o now. 8 .5 Er r o r d i sp l a y w i t h LED Pow e r LED doe s not light u p Check t he power supply and t he connect ing cables! I f t he LED does not light up, disconnect t he device from t he power supply and carefully rem ove t he fuse! Test t he fuse. I f it is defect ive, replace it wit h a fuse specified by t he m anufact urer! I f t he above m easures do not solve t he problem , leave t he device disconnect ed and cont act t he m anufact urer! 8 .6 Re a d e r d oe s n ot r e sp on d Check if t he int erface connect ion cable is undam aged and correct ly connect ed t o bot h reader and host ! Check t he st at us as indicat ed by t he LED! I f you are unsure of t he enabled com m unicat ion int erface, t ry bot h ( RS232 and Et hernet ) ! Cont act Brooks Aut om at ion ( Germ any) Gm bH regarding t he firm ware of t he device and t he firm ware updat e soft ware! I f t hese m easures do not solve t he problem , cont act t he m anufact urer! Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 160 Ch a p t e r 8 Se r vice a nd Tr ouble shoot ing 8 .7 Re se t In the case of a malfunction, a hardware reset can be performed by switching the power supply off and on. After the reset, the reader performs a self-test. The self-test can take up to five seconds. In the first step of these self-tests, all LEDs light up. If the test was successful, all LEDs, except for the power LED, go out! 8 .8 Po w e r cu t After a power cut, the reader performs a reset with self-test (see Reset). 8 .9 Sof t w a r e r e le a se s R e l e a se date V e r si o n D e scr i p t i o n March 2011 UHFI20 First version with flexible EPC length 8 . 1 0 Cu s t o m e r s e r v i ce Brooks Automation (Germany) GmbH RFID Division Gartenstr. 19 D-95490 Mistelgau GERMANY Telephone +49 (0) 9279 - 991 550 Fax E-mail +49 (0) 9279 - 991 501 rfid.support@brooks.com 24 hour technical support hotline (Brooks): US and Canada +1 978 262 2900 Europe Japan China Taiwan Korea Singapore +49 1804 2255 4887 +81 45 477 5980 +86 21 5131 7066 +886 3 5525225 +82 31 288 2500 +65 6464 1481 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 161 Ch a p t e r 9 Dism a nt ling a nd St ora ge D ism a n t lin g a n d St or a g e This chapt er gives you an overview of t he following t opics: ■ Dism ant ling ■ St orage 9 .1 D ism a n t lin g Rem ove t he power supply! Rem ove all cables! Loosen and rem ove t he m ount ing screws! Rem ove t he device from t he inst allat ion area! 9 .2 St or a g e St ore t he reader and it s com ponent s in a clean and dry environm ent wit h t he power supply disconnect ed. Make sure t he cont act s rem ain clean. Observe t he necessary st orage condit ions. Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 162 Ch a p t e r 1 0 Tra nsport a nd Disposa l 10 Tr a n sp or t a n d D isp osa l This chapt er gives you an overview of t he following t opics: ■ Transport ■ Disposal 1 0 . 1 Tr a n sp o r t For t ransport at ion purposes such as m ailing, use a firm cardboard box. Use adequat e padding m at erial t o prot ect t he device on all sides. 1 0 . 2 D isp osa l The device and it s com ponent s are m ade of various m at erials. Dispose of t hese m at erials separat ely, and observing t he legal regulat ions of your count ry. Do not dispose of t he device in regular household wast e. Disconnect t he elect ronic com ponent s from t he case and dispose of t hem as follows: ■ t he housing as scrap m et al ■ t he elect ronic com ponent s, ant ennas and cables as elect ronic wast e Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 163 I ndex Access word 46 Assem bly 33 B - Sensor st at us 116 Bulk t im e 46 CMD 46 Com m ands 43 Com m issioning 36 Dat a words 46 , 50 Declarat ion of Conform it y 10 Direct ion 47 E - Error m essage 120 EPC 47 EPC code 47 Et hernet set t ings 37 Ex flag 48 Ext ension 48 F - Param et er query 107 Filt er 49 Filt er m ask 49 Filt er Num ber 49 Fram e I D 49 H - Heart beat 121 Head I D 49 High byt e 41 Hum idit y 30 I nst allat ion dim ensions 33 Liabilit y 12 Low byt e 41 M - EPC scanning 58 Malfunct ions 34 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 164 I ndex Mask 50 Mem ory address 50 Mem ory bank 50 O - set out put 117 On/ Off 51 Out put st at e 51 P - Set param et er 108 Param et er 0, Com m unicat ions Port 130 Param et er 01, Baud rat e 130 Param et er 03, Parit y 130 Param et er 04, MsgRepeat Delay Tim e 131 Param et er 06, MsgMaxRepeat 131 Param et er 07, First Byt e of t he Serial Num ber 131 Param et er 08, Second Byt e of t he Serial Num ber 131 Param et er 100, Global ETSI Channel List 136 Param et er 101, ETSI Channel List Ant enna 1 136 Param et er 102, ETSI Channel List Ant enna 2 137 Param et er 103, ETSI Channel List Ant enna 3 137 Param et er 104, ETSI Channel List Ant enna 4 137 Param et er 105, Channel Swit ching Mode 138 Param et er 106, Transm ission Out put Ant enna Port 1 138 Param et er 107, Transm ission Out put Ant enna Port 2 138 Param et er 108, Transm ission Out put Ant enna Port 3 138 Param et er 109, Transm ission Out put Ant enna Port 4 138 Param et er 11, Reader I D 131 Param et er 110, Ant enna Cable Port 1 At t enuat ion 139 Param et er 111, Ant enna Cable Port 2 At t enuat ion 139 Param et er 112, Ant enna Cable Port 3 At t enuat ion 139 Param et er 113, Ant enna Cable Port 4 At t enuat ion 139 Param et er 114, Ant enna Gain Port 1 139 Param et er 115, Ant enna Gain Port 2 139 Param et er 116, Ant enna Gain Port 3 140 Param et er 117, Ant enna Gain Port 4 140 Param et er 118, Ext ended Result flag 140 Param et er 119, Glim sed Tim eout Count 140 Param et er 12, Acknowledgm ent Error Message 131 Param et er 120, Observed Threshold Count 140 Param et er 121, Observed Tim eout Count 140 Param et er 122, Com m unicat ions St andard 141 Param et er 123, ETSI Power Check Over All Allowed Channels 141 Param et er 124, Com m St andard Cent er Freq CH0 141 Param et er 125, Com m St andard Channel Widt h 141 Param et er 126, Com m St andard Max Channel Tim e 141 Param et er 127, Com m St andard Channel Widt h 142 Param et er 128, Com m St andard First Channel 142 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 165 I ndex Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er Param et er 129, 130, 131, 132, 133, 134, 135, 136, 137, 138, 139, 140, 141, 142, 143, 144, 145, 146, 147, 148, 149, 150, 151, 152, 153, 154, 155, 156, 157, 158, 159, 160, 161, 162, 163, 164, 165, 166, 167, 168, 169, 170, 171, 172, 173, 174, 175, 176, 177, Com m St andard Last Channel 142 I nt elligent Writ e 142 Writ e Verify 142 Tag Com m Query Target 142 Tag Com m Query Sel 143 Ant enna I ndependend Operat ion 143 RF I nt erface Tim e t o Power Off 143 RF I nt erface Modulat ion Type 143 RF I nt erface Mult iplexing Ant enna Port 1 143 RF I nt erface Mult iplexing Ant enna Port 2 144 RF I nt erface Mult iplexing Ant enna Port 3 144 RF I nt erface Mult iplexing Ant enna Port 4 144 RF I nt erface Mult iplexing Ant enna Port 5 145 RF I nt erface Mult iplexing Ant enna Port 6 145 RF I nt erface Mult iplexing Ant enna Port 7 145 RF I nt erface Mult iplexing Ant enna Port 8 146 RF I nt erface RSSI Threshold 1 146 RF I nt erface RSSI Threshold 2 146 RF I nt erface RSSI Threshold 3 146 RF I nt erface RSSI Threshold 4 146 RF I nt erface Mult ipower Tag Access 1 147 RF I nt erface Mult ipower Tag Access 2 147 RF I nt erface Mult ipower Tag Access 3 147 RF I nt erface Mult ipower Tag Access 4 147 RF I nt erface Max Allowed Ant enna Out put Power 1 147 RF I nt erface Max Allowed Ant enna Out put Power 2 147 RF I nt erface Max Allowed Ant enna Out put Power 3 148 RF I nt erface Max Allowed Ant enna Out put Power 4 148 Tag Com m Use Pilot Tone 148 Tag Com m I nit ial Q 148 Tag Com m Session 148 Tag Com m Max Errors 148 Tag Com m Default Profile 149 RF I nt erface Mult iplexing Exposure Tim e 1 149 RF I nt erface Mult iplexing Exposure Tim e 2 149 RF I nt erface Mult iplexing Exposure Tim e 3 149 RF I nt erface Mult iplexing Exposure Tim e 4 150 RF I nt erface Mult iplexing Exposure Tim e 5 150 RF I nt erface Mult iplexing Exposure Tim e 6 150 RF I nt erface Mult iplexing Exposure Tim e 7 150 RF I nt erface Mult iplexing Exposure Tim e 8 151 RF I nt erface Enable RSSI Threshold At Specific Cm ds 151 RF I nt erface Flash Writ e Addit ional Power 151 Tag Com m Force Power Off Aft er EPC Writ e 151 Tag Com m Transm it Get EPCs Pre Select 152 Tag Com m Transm it Select I f No Filt er I s On 153 Tag Com m Num ber Of EPC Word 153 Tag Com m Use Block Writ e 153 Tag Com m Disable Receiving NXP Read Prot ect ed Tags 154 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 166 I ndex Param et er 178, Host Com m A Sync Addit ional RSSI Dat a Delivery Delt a 154 Param et er 179, Host Com m Use Milliseconds As Tim e st am p 155 Param et er 20, Sensor act ivit y 132 Param et er 21, Delay t im e for sensor 1 132 Param et er 22, Delay t im e for sensor 2 132 Param et er 23, Delay t im e for sensor 3 132 Param et er 24, Delay t im e for sensor 4 132 Param et er 26, Wat chport for sensor 1 133 Param et er 27, Wat chport for sensor 2 133 Param et er 28, Wat chport for sensor 3 133 Param et er 29, Wat chport for sensor 4 133 Param et er 33, Highbyt e Aut oread Bulkt im e 133 Param et er 34, Lowbyt e Aut oread Bulkt im e 134 Param et er 39, Adj ust I / O Num bering 134 Param et er 40, Pollingport 134 Param et er 41, Show UHF Going 135 Param et er 93, Wait Tim e Reader Response 135 Param et er 94, Wait Tim e Reader Acknowledge 135 Param et er 95, Reader Cont rol Tim e 135 Param et er 96, St op Aut om at ic Read 135 Param et er 97, St op Sensor Message 135 Param et er 98, Error 'Unexpect ed' 136 Param et er 99, Fact ory Reset / Fine Version 136 Param et er no. 51 Param et ers 126 Payload 52 Power supply 34 Profile num ber 52 Prohibit ion sym bols 15 Q - Queries of t he out put st at us 118 Reader I D 52 RECOMMI SSI ON 52 Relat ive hum idit y 30 Response code 53 Result 53 Safet y I nst ruct ions 14 Safet y inst ruct ions 30 Safet y sym bols 15 Sensor st at e 53 Sensor t riggered aut om at ic reading 125 Serial num ber 53 Soft ware version 53 Sub- D Socket 35 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 167 I ndex T and UAM - Enable read polling EPC 75 Tem perat ure 30 Transponder error code 54 UAA - Enable Read Polling Raw 77 UAB - Erase Block 85 UAE - End polling 92 UAK - Kill EPC t ransponder 87 UAL - Lock EPC t ransponder 86 UAR - Polling Transponder- Rat e 89 UAW - Polling Writ e Dat a 81 UAX - Polling Read Dat a 79 UAZ - Polling Writ e Masked Dat a 83 UBW - Erase block of all EPC t ransponders 68 UBZ - Erase block of all EPC t ransponders ( defined EPC code) 69 UCC - Act ivat e Polling NXP- UCODE- G2X Change EAS 95 UCE - Act ivat e polling NXP- UCODE- G2X EAS alarm 96 UCN - Act ivat e polling NXP- UCODE- G2X Reset Read Prot ect 94 UCX - Act ivat e polling NXP- UCODE- G2X Read Prot ect 93 UFG - Read filt er dat a 100 UFP - Set filt er 99 UFR - Read filt er dat a 98 UFW - Set filt er dat a 97 UGD - Det erm ine Default Param et er Set 113 UGK - Det erm ine act ive param et er set 110 UGL - Read list of radio profiles 101 UGP - Read act ive radio profile 102 UGT - Read UTC t im e 123 UKW - Killing all EPC t ransponders 72 UKZ - Killing all EPC t ransponders ( defined EPC code) 73 ULW - Locking all EPC t ransponders 70 ULZ - Locking all EPC t ransponders ( defined EPC code) 71 UMW - Writ e dat a range of all EPC- t ransponders m asked 66 UMZ - Writ e dat a range of all EPC- t ransponders ( defined EPC code) m asked 67 UNH - Hardware reset 104 UNR or N - Soft ware reset 105 UPD - Define Default Param et er 114 UPE - Fact ory Reset / Fact ory Set t ing 106 UPK - Define t he act ive param et er set 111 UPP - Set act ive radio profile 103 UPT - Set UTC t im e 124 URB - EPC Bulk reading 60 URY - Read dat a area ( defined EPC code) 57 UTC 54 UVR or V - Query soft ware version 122 UWW - Writ e dat a range of EPC t ransponders 62 UWZ - Writ e dat a range of EPC- t ransponders ( defined EPC code) 64 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 168 I ndex W - Writ e EPC code 61 Warning sym bols 15 X or URX - Read dat a area 55 Pr odu ct M a n u a l - RFI D Re a de r UF7 0 Ce r t u m 169
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Author : shertel Create Date : 2012:05:08 16:46:30Z Keywords : RFID, Brooks Automation, UHF, UF70 Certum, Reader, Transponder, Tag, Antenna Modify Date : 2012:05:09 09:41:32+02:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Creator Tool : FrameMaker 7.2 Metadata Date : 2012:05:09 09:41:32+02:00 Producer : Acrobat Distiller 9.0.0 (Windows) Format : application/pdf Title : Product Manual Description : RFID Reader UF70 Certum Creator : shertel Subject : RFID, Brooks Automation, UHF, UF70 Certum, Reader, Transponder, Tag, Antenna Document ID : uuid:d32eb9cf-0dd0-4471-9ac5-ec292360eab0 Instance ID : uuid:a62abbbc-cd65-4d50-9d41-cc0cfb76504e Page Layout : SinglePage Page Mode : UseOutlines Page Count : 169EXIF Metadata provided by EXIF.tools