Budderfly S0811011 Budderfly Multi-Way Switch User Manual QCVS0811011

Budderfly LLC Budderfly Multi-Way Switch QCVS0811011

Users Manual

Download: Budderfly S0811011 Budderfly Multi-Way Switch User Manual QCVS0811011
Mirror Download [FCC.gov]Budderfly S0811011 Budderfly Multi-Way Switch User Manual QCVS0811011
Document ID2151004
Application IDSr+T71hh6oUOpRdP52fhKg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize15.31kB (191408 bits)
Date Submitted2013-12-24 00:00:00
Date Available2013-12-24 00:00:00
Creation Date2013-12-23 21:48:20
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2013-12-23 21:48:20
Document TitleQCVS0811011_User Manual.pdf
Document CreatorPScript5.dll Version 5.2.2
Document Author: Ali Olleik

Description:
InstallingaBudderflyadaptertransformsyourbuilding’sexistingwiringintothe“BudderflyOpenNetwork”andallowsthe
adaptertomonitorenergyconsumptionandcommunicatethedatatoafacilitycontroller.
BudderflyadaptorswillusetheexistingpowerlineandtheRFforcommunicationandthusrequirenoreͲwiring.
UsingourBudderflysoftware,youcanvisualizeconsumptiondataandmanageeachindividualadapter.
The Budderfly MultiͲWay light switch is a component of the Budderfly system and designed to work with all other
Budderflydevices.ItisaplugͲandͲplayreplacementforyourexistinglightswitch.Onceinstalled,theBudderflyswitches
alsoactasrepeaterstoextendtherangeofthenetworkandincreaseefficiency.
WARNING–ELECTRICALSHOCKHAZARD
x TheBudderflyMultiͲWaylightswitchisintendedforinstallationinaccordancewiththeNationalElectricCodeand
localregulationsintheUnitedStates.
 x Ifyouarenotknowledgeableorcomfortablewithelectricalcircuitry,youshouldhaveaqualifiedelectricianinstall
 theBudderflyMultiͲWaylightswitchforyou.
Thisdeviceisdesignedforuseonlywithpermanentlyinstalledfixtures.
Warning
RISKOFFIRE/ELECTRICALSHOCK/BURNS
ExerciseextremecautionwhenusingBudderflyswitchingdevicestocontrolappliances.
ToavoidtheriskofFire,ElectricalShock,Burnsorotherhazardswerecommendthefollowing:
x InstalltheBudderflyswitchesindooronly.
x NeverusetheBudderflyswitchestocontrolmedicaland/orlifesupportequipment.
x DonotusetheBudderflyswitchestocontrolelectricheatersoranyotherapplianceswhichmaypresenta
hazardousconditionduetounattendedorunintentionalpoweroncontrol.
NeverusetheBudderflyswitcheswithloadsthatexceedthemaximumratingspecified.
PartNoS0811011
Installation:
TheBudderflyMultiͲWaylightswitchmaybeusedinnewinstallationsortoreplaceanexistingwallswitch.Itcouldbeusedeitherasa2Ͳwayswitch,orasa3Ͳwayswitch.Thewiring
stepsforbothconfigurationsareexplainedinthefollowingdiagrams:
2ͲWayConfiguration:
3ͲWayConfiguration:
WiringInformation
x Important:Budderflyswitchesareratedforandintendedtobeusedonlywith
copperwires.
o.
x Use12AWGorlargerwiressuitablefor80 
x Remove3/4"(1.9cm)ofinsulationfromeachwire.
x Connectasfollows:Twiststrandsofeachendtightlytogether.Holdbareends
ofwirestogetherandpushfirmlyintowireNut.ScrewNutclockwisemaking
surethatnobareconductorshowsbelowtheconnector.
1. Atthecircuitbreakerorfusepanel,disconnectthepowerforallofthecircuitsin
theswitchjunctionbox.
2. Double Check that the power is OFF to the switch box before continuing by
tryingtoturnonthecontrolledload.
3. Remove the wall plate from the switch you are replacing. Then, unscrew the
switchitselfandpullitoutfromthejunctionbox.
4. Disconnectthewiresfromtheswitchyouarereplacing.
5. Followthewiringinformationprovidedbelowtoconnectthewiresasfollows:
o ConnecttheGROUNDwire(usuallyBareCopperorGreen)totheGroundwire
ofBudderflySwitch(Yellow&Green).
o 2ͲWayconfiguration:
ƒ ConnecttheLOADwire(usuallyBlack)thatgoestothelighttothe
Traveler#1(Red)wireofBudderflySwitch.
o 3ͲWayconfiguration:
ƒ ConnecttheTraveler#1(UsuallyRed)andTraveler#2(UsuallyBlue)wires
oftheStandardMultiͲWaySwitchtotheTraveler#1(Red)andTraveler#2
(Blue)wiresofBudderflySwitchrespectively.
ƒ ConnecttheLOADwire(usuallyBlack)thatgoestothelighttotheLOAD
wire(usuallyBlack)oftheStandardMultiͲWaySwitch.
o ConnecttheLINEwire(usuallyBlack)thatcomesfromtheelectricalservice
paneltotheHOTwireofBudderflySwitch(Black).
o ConnecttheNEUTRALwire(usuallyWhite)totheNeutralwireofBudderfly
Switch(White).
6. Afteryouhaveconnectedallofthewires,ensurethatallofthewireconnectors
arefirmlyattachedandthatthereisnoexposedcopperexceptfortheGROUND
wire.
7. GentlyplaceBudderflyswitchintothejunctionbox,orientingtheunitwiththe
LEDbarontheleft.Then,screwtheswitchintoplace.
8. Reinstallthewallplate
9. Enablepowertotheswitchfromthecircuitbreakerorfusepanel
10. After the Power LED comes on, test that the switch is working properly by
turningthelightonandoff
11. AddthedeviceaddresstotheBudderflywebapplication.
WARNING–ELECTRICALSHOCKHAZARD
x TurnOFFthepowertothebranchcircuitfortheswitchandlightingfixtureat
theservicepanel.
x AllwiringconnectionsmustbemadewiththePOWEROFFtoavoidpersonal
injuryand/ordamagetotheswitch.
Features:
Communication:
Ͳ RemoteOn/Offcontrol
Ͳ ManualOn/Offcontrol
Ͳ Abilitytocreateagroupofdevices
Ͳ Abilitytomonitorpowerconsumption
Ͳ LEDindicatorstoshowthestateoftheswitch
On/OffControl:
Ͳ RemoteControl:
o TheBudderflyswitchescanbecontrolledremotelythrutheBudderflysoftware.
o TheBudderflysoftwarewillinformyouthattheactionwassuccessful.Incasetheaction
failed,pleaserepeattheprocedure
Ͳ Manual Control: In addition to the Remote control, the Budderfly switches can be
controlledmanually.Tapthetoporbottomoftherockertogglethestateconnectedload.
DeviceGrouping:
Ͳ UsingtheBudderflywebapplication,itispossibletocreateaGroupofdevicesthatcanbe
controlledremotelysimultaneouslywithjustoneclick.
Ͳ Budderflyswitchescanjoin/disjoingroupsatanytime.
Powerconsumption:
Budderfly switches will measure the current, voltage, power and energy consumed by the
connectedload,andwillstorethecumulativeenergyconsumption.
The data can be accessed at any time thru the Budderfly software. The user can generate
reports,monitortheconsumptionorcheckexpenses.
LEDIndicators:
TheBudderflyswitchesareequippedwithtwoLEDstoindicatethecurrentstateofthedevice.
ThebehavioroftheseLEDsisexplainedinthefollowingtable:
RedLED
GreenLED
Status
ON
OFF
ON
OFF
Deviceisnotpowered.
X
Deviceispowered.LightingloadisOFF.
X
Deviceispowered.LightingloadisON.
X
Reset:
Ifthedevicestopsresponding,itcanberestartedbypushingtheResetButton.AnonͲmetallic
pinshouldbeusedtopushtheresetbutton.
Noneofthestoredparameterswillbeaffected.
The Budderfly MultiͲWay light switchesuse the power line and radio frequency to
communicatewiththeBudderflyFacilityController.
The switches have the capability to respond to (but not limited to) the following
commands:
x TurnON/OFF:TheconnectedlightingloadwillturnON/OFF.
x Join/Disjoingroup“X”:TheswitchwillJoin/Disjointhegroup“X”.Eachswitchcan
beamemberofseveralgroupsatthesametime.
x DirectRTCsynchronization:Theswitchcanreceiveacommandtosynchronizeits
“RealTimeClock”
x Get Actual Measurement: When the switch receives a “Get Measurement”
command,itwillsendbacktothefacilitycontrollerastringofdatathatcontains:
Ͳ TheCurrentinAmpere“A”.
Ͳ ThePowerinWatt“W”.
Ͳ ATimestamp.
x GetStoredMeasurement:TheswitchwillsendbacktotheFacilityControllerthe
storedelectricalmeasurements.
x DirectResetCommands:Theswitchcanreceive3typesofresetcommands:
Ͳ HardReset:Thiscommandwillrestartthedevicewithoutaffectinganystored
parameter.
Ͳ DataReset:ThiscommandwilleraseallthemeasurementandRTCdatastored
inthenonͲvolatilememory.
Ͳ Disjoin Group: This command will remove the device from all the joined
groups.
x GroupResetCommands:Theaboveresetcommandscanbedirectedtoagroup
ofdevicesinsteadofjustonedevice.
Warranty:
WARNING–ELECTRICALSHOCKHAZARD
Specifications:
x Power:120VͲ277VAC/60Hz
x MaximumLoads:
o 120VAC,60Hertz:1600WforTungsten,1400WforElectronicballast,800W
forStandardballast
o 277VAC,60Hertz:3300WforElectronicballast,1200WforStandardballast.
x NeutralLine:Required
Specifications are subject
x OperatingTemperature:0 Cto+40 C
to change without prior
x Certification:UL&FCCcertificationsareinprogress
notice due to continuous
x Forindooruseonly
productimprovement.
BudderflyLLCwarrantstotheoriginalconsumerpurchaserandnotforthebenefit
ofanyoneelsethatthisproductatthetimeofitssalebyBudderflyisfreeofdefects
inmaterialandworkmanshipundernormalandproperuseforaperiodofthree(3)
years from date of delivery to you.  Budderfly’s only obligation is to correct such
defectsbyrepairorreplacement,atitsoption,ifwithinsuchthreeyearperiodthe
productisreturnedprepaidviaBudderfly’sReturnedMaterialsAuthorization(RMA)
process to Budderfly LLC, Att: Quality Assurance Department, 2 Trap Falls Road,
Suite 507, Shelton, CT 06484.  In no case is product to be returned without first
obtaininganRMA.
Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthis
productorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperly
orinanimproperenvironment,overloaded,misused,opened,abused,oralteredin
anymanner,orisnotusedundernormaloperatingconditionsornotinaccordance
with any labels or instructions.  There are no other or implied warranties of any
kind, including merchantability and fitness for a particular purpose, but if any
impliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuch
impliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuch
impliedwarranty,includingmerchantabilityandfitnessforaparticularpurpose,is
limited to three years.  Budderfly is not liable for incidental, indirect, special, or
consequentialdamages,includingwithoutlimitation,damageto,orlossofuseof,
any equipment, lost sales or profits or delay or failure to perform this warranty
obligation. Budderfly’s liability on any claim for damages arising out of in
connection with the manufacture, sales, installation delivery, or use of the
product shall never exceed the purchase price of the product. The remedies
providedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedon
contract,tortorotherwise.
Neveruseametallicpintopresstheresetbutton.

WARNING
Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser’sauthoritytooperatethisequipment
FCCComplianceStatement
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:
(1) Thisdevicemaynotcauseharmfulinterferenceand
(2) Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaclassBdigitaldevice,pursuanttopart15oftheFCCRules.Theselimits
aredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcan
radiateradiofrequencyenergyandifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradio
communications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescause
harmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotryto
correcttheinterferencebyoneormoreofthefollowingmeasures:
x Reorientorrelocatethereceivingantenna.
x Increasetheseparationbetweentheequipmentandreceiver.
x Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.
x Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
Theuseriscautionedthatchangesandmodificationsmadetotheequipmentwithouttheapprovalofmanufacturercouldvoidtheuser'sauthority
tooperatethisequipment.
FCCID:(NoFCCIDhasbeenissuedyet;FCCCertificationisinprogress)
MadeinChina

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Source Modified                 : D:20130926145333
Create Date                     : 2013:12:23 21:48:20+08:00
Modify Date                     : 2013:12:23 21:48:20+08:00
Metadata Date                   : 2013:12:23 21:48:13+08:00
Creator Tool                    : PScript5.dll Version 5.2.2
Document ID                     : uuid:6F644DDED86BE311942FC912E9B9FBF2
Instance ID                     : uuid:a31daca1-5aa0-4fc4-aba8-edba3f804d79
Derived From Instance ID        : uuid:4acf9789-ac7c-455a-bd3c-9da4039e2aec
Derived From Document ID        : uuid:92d00197-95c7-46a4-851c-b378329ab155
Format                          : application/postscript
Creator                         : Ali Olleik
Title                           : QCVS0811011_User Manual.pdf
Page Count                      : 3
Author                          : Ali Olleik
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QCVS0811011

Navigation menu