CAEN RFID srl CAENRFID015 UHF RFID Ultra Compact Reader User Manual R1230CB
CAEN RFID srl UHF RFID Ultra Compact Reader R1230CB
Contents
- 1. users manual
- 2. technical information manual
- 3. quark up technical information manual
- 4. Technical Information Manual
quark up technical information manual
R1270 500mW UHF RFID Ultra Compact Module R1270CEVB Quark Up Reader Evaluation Board Technical Information Manual Revision n. 00 29/05/2014 Visit Quark Up R1270 web page and you will find the latest revision of data sheets, manuals, certifications, technical drawings, software and firmware. All you need to start using your reader in a few clicks! Scope of Manual The goal of this manual is to provide the basic information to work with the Quark Up R1270 500mW UHF RFID Ultra Compact Module. Change Document Record Date 29 May 2014 Revision 00 Changes Preliminary release Pages Reference Document [RD1] EPCglobal: EPC Radio-Frequency Identity Protocols Class-1 Generation-2 UHF RFID Protocol for Communications at 860 MHz – 960 MHz, Version 1.1.0 (December 17, 2005). CAEN RFID srl Via Vetraia, 11 55049 Viareggio (LU) - ITALY Tel. +39.0584.388.398 Fax +39.0584.388.959 info@caenrfid.com www.caenrfid.com © CAEN RFID srl – 2014 Disclaimer No part of this manual may be reproduced in any form or by any means, electronic, mechanical, recording, or otherwise, without the prior written permission of CAEN RFID. The information contained herein has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. CAEN RFID reserves the right to modify its products specifications without giving any notice; for up to date information please visit www.caenrfid.com. Preliminary Product Information This document contains information for a new product. CAEN RFID reserves the right to modify this product without notice. “Preliminary” product information describes products that are ready for production, but for which full characterization data is not yet available. CAEN RFID believes that the information contained in this document is accurate and reliable. However, the information is subject to change without notice and is provided “AS IS” without warranty of any kind (Express or implied). You are advised to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. No responsibility is assumed by CAEN RFID for the use of this information, including use of this information as the basis for manufacture or sale of any items, or for infringement of patents or other rights of third parties. Federal Communications Commission (FCC) Notice (Preliminary) This device was tested and found to comply with the limits set forth in Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This device generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instruction manual, the product may cause harmful interference to radio communications. Operation of this product in a residential area is likely to cause harmful interference, in which case, the user is required to correct the interference at their own expense. The authority to operate this product is conditioned by the requirements that no modifications be made to the equipment unless the changes or modifications are expressly approved by CAEN RFID. Disposal of the product Do not dispose the product in municipal or household waste. Please check your local regulations for disposal/recycle of electronic products. Index … Scope of Manual ...........................................................................................................................................................................2 Change Document Record ............................................................................................................................................................2 Reference Document ....................................................................................................................................................................2 Index … .......................................................................................................................................................................................... 4 List of Figures................................................................................................................................................................................. 5 List of Tables .................................................................................................................................................................................. 5 Introduction ........................................................................................................................................................................ 6 General Information .....................................................................................................................................................................7 Reader..............................................................................................................................................................................7 Evaluation Board ..............................................................................................................................................................7 Accessories ...................................................................................................................................................................................8 R1270 Quark Up ReaderAccessories ................................................................................................................................8 R1270CEVB Quark Up Evaluation Board Accessories .......................................................................................................8 Development Kit ...........................................................................................................................................................................9 Ordering Options ..........................................................................................................................................................................9 Installation Notice ......................................................................................................................................................................10 Quark Up R1270 ................................................................................................................................................................ 11 Technical Specifications Table ....................................................................................................................................................12 External Connections ..................................................................................................................................................................13 R1270 supply and I/O connector electrical characteristics ............................................................................................15 Power supply connection ...............................................................................................................................................16 General purpose I/O connections ..................................................................................................................................17 External reset .................................................................................................................................................................17 UART connection ...........................................................................................................................................................18 USB connection ..............................................................................................................................................................19 Antenna port specifications ...........................................................................................................................................19 Reader – Tag Link Profiles...........................................................................................................................................................20 Firmware Upgrade ......................................................................................................................................................................20 BSL operation .................................................................................................................................................................20 Firmware upgrade via R1270CEVB board ......................................................................................................................21 PCB Pad Layout ...........................................................................................................................................................................23 Quark Up R1270CEVB ........................................................................................................................................................ 24 Technical Specifications Table ....................................................................................................................................................25 Connection diagram ...................................................................................................................................................................25 Installation Notice ......................................................................................................................................................................26 Technical drawings .....................................................................................................................................................................26 Electrical scheme ........................................................................................................................................................................27 External Connections ..................................................................................................................................................................28 Installing the USB Virtual COM port driver .................................................................................................................................29 Quark Up Regulatory Compliance ...................................................................................................................................... 30 FCC Compliance ..........................................................................................................................................................................31 Quark Up R1270 - R1270CEVB - Technical Information Manual List of Figures Fig. 1.1: Quark Up R1270 500mW UHF RFID Ultra Compact Module ......................................................................................................7 Fig. 1.2: Quark Up R1270CEVB - Quark-Up Reader Evaluation Board .....................................................................................................7 Fig. 1.3: R1270CEVB Accessories .............................................................................................................................................................8 Fig. 1.4: R1270CXDK: R1270 - Development kit with reader, adapter, antennas, cable and demo tags .................................................9 Fig. 1.5: Connection of the R1270CEVB to the Quark Up R1270 module ..............................................................................................10 Fig. 2.1: Quark Up R1270 technical drawings ........................................................................................................................................13 Fig. 2.2: Quark Up R1270 power supply connection ..............................................................................................................................16 Fig. 2.3: Quark Up R1270 GPIO connection example.............................................................................................................................17 Fig. 2.4: Quark Up R1270 external reset ................................................................................................................................................17 Fig. 2.5: Quark Up R1270 RS232 connection .........................................................................................................................................18 Fig. 2.6: Quark Up R1270 USB connection .............................................................................................................................................19 Fig. 2.7: BSL sequence ...........................................................................................................................................................................20 Fig. 2.8: PCB pad layout .........................................................................................................................................................................23 Fig. 3.1: Quark Up R1270CEVB technical drawing .................................................................................................................................26 Fig. 3.2: Quark Up R1270CEVB electrical scheme ..................................................................................................................................27 Fig. 3.3: Quark Up R1270CEVB SMT pads ..............................................................................................................................................28 List of Tables Tab. 2.1: Quark Up R1270 Technical Specifications ...............................................................................................................................12 Tab. 2.2: Quark Up R1270 connector pinout .........................................................................................................................................14 Tab. 2.3: Quark Up R1270 supply and I/O connector electrical characteristics .....................................................................................16 Tab. 2.4: RF port pinout .........................................................................................................................................................................19 Tab. 2.5: RF port electrical characteristics .............................................................................................................................................19 Tab. 2.6: Quark Up R1270 reader to tag link profiles ............................................................................................................................20 Tab. 3.1: R1270CEVB - Quark-Up Reader Evaluation Board ..................................................................................................................25 Tab. 3.2: Quark Up R1270CEVB GPIO connector pinout........................................................................................................................28 Tab. 3.3: Quark Up R1270CEVB SMT pads signals .................................................................................................................................28 Quark Up R1270 - R1270CEVB - Technical Information Manual 1 Introduction This Chapter gives general information about the Quark Up R1270 500mW UHF RFID Ultra Compact Module. It contains these topics: General Information Accessories Development Kit Ordering Options Installation Notice Quark Up R1270 - R1270CEVB - Technical Information Manual General Information Reader © The Quark-Up (Model R1270), OEM reader of the easy2read Family, is an UHF multiregional ultra compact reader for low power, high performances UHF RFID applications. With programmable output power in 18 steps from 10dBm to 27dBm, the reader can detect tags at more than 3 mt of distance (depending on antenna and tag dimensions). Due to its low power consumption, the module is specifically designed to be easily integrated in battery powered devices. The radio frequency core of the module permits to achieve fast reading and to be used in dense reader and dense tag environments for top-class rated performances. The compactness of the device and the board-to-board connector allow to embed the R1270 inside the new small form factor industrial handhelds, smartphone accessories and other compact form factor devices. The R1270 complies with and can operate in both European and US regulatory environments and due to its multiregional capabilities, it's ideal for integration in devices requiring compliance to different geographical regions. Fig. 1.1: Quark Up R1270 500mW UHF RFID Ultra Compact Module Evaluation Board The R1270CEVB evaluation board allows to manage the R1270 Quark Up reader directly via USB interface. This board is particularly suited for Quark Up reader evaluation and SW development purposes. Fig. 1.2: Quark Up R1270CEVB - Quark-Up Reader Evaluation Board Quark Up R1270 - R1270CEVB - Technical Information Manual Accessories R1270 Quark Up ReaderAccessories None. R1270CEVB Quark Up Evaluation Board Accessories Check for the supplied accessories below: No. 1 USB cable Fig. 1.3: R1270CEVB Accessories Quark Up R1270 - R1270CEVB - Technical Information Manual Development Kit R1270CXDK – 500mW UHF RFID Ultra Compact Module Development Kit is available: Fig. 1.4: R1270CXDK: R1270 - Development kit with reader, adapter, antennas, cable and demo tags The R1270 Quark Up reader development kit is a complete RFID set up, for a quick implementation of RFID solutions. It includes: n. 1 R1270 - 500mW UHF RFID Ultra Compact Module n. 1 R1270CEVB - Quark-Up Reader Evaluation Board n.1 Circular Polarized Quadrifilar Antenna U.FL ETSI n.1 Circular Polarized Quadrifilar Antenna U.FL FCC n. 1 Set of Labels n. 1 A927Z Temperature Logger Tag n. 1 RT0005 Temperature Logger Tag n. 1 USB cable Ordering Options Reader Development kit Accessories Code WR1270CXAAAA WR1270CXDKAA WR1270CEVBXA WANT020XAUFL WANT021XAUFL Description R1270 - Ultra Compact Embedded UHF RFID Reader R1270 - Development kit with reader, adapter, antennas, cable and demo tags R1270CEVB - Quark-Up Reader Evaluation Board ANT020/UFL - Quad - Circular polarized quadrifilarantenna (ETSI) - U.FL ANT021/UFL - Quad - Circular polarized quadrifilarantenna (FCC) - U.FL Quark Up R1270 - R1270CEVB - Technical Information Manual Installation Notice The correct way to connect the Quark Up R1270 module to the evaluation board is shown in the following pictures: Fig. 1.5: Connection of the R1270CEVB to the Quark Up R1270 module 10 Quark Up R1270 - R1270CEVB - Technical Information Manual 2 Quark Up R1270 This Chapter provides the basic information to work with the Quark Up R1270 500mW UHF RFID Ultra Compact Module. It contains these topics: Technical Specifications Table External Connections Reader – Tag Link Profiles Firmware Upgrade PCB Pad Layout Quark Up R1270 - R1270CEVB - Technical Information Manual 11 Technical Specifications Table Frequency Band RF Power Output Power Accuracy Antenna VSWR Requirement Antenna Connector Frequency Tolerance Number of Channels Standard Compliance Digital I/O Connectivity DC Power Power Consumption Operating Temperature Dimensions Weight 902÷928 MHz (FCC part 15) 865.600÷867.600 MHz (ETSI EN 302 208) Programmable in 18 levels (1dB step) from 10dBm to 27dBm (from 10mW to 500mW) conducted +/- 1dB 2:1 or better for optimum performances Nr. 1 U.FL type ±10 ppm over the entire temperature range 4 channels (compliant to ETSI EN 302 208 v1.3.1) 50 hopping channels (compliant to FCC part 15.247). EPC C1G2 [RD1]/ISO 18000-6C 4 I/O lines (3.3V level; Iout=3mA max) USB interface: One USB 2.0 Full Speed (12Mbit/s) device port UART Serial Port: Baudrate: up to 115200 Databits: 8 Stopbits: 1 Parity: none Flow control: none 3.3 V I/O Voltage Level 5.0 VDC+/-5% 2.7W @ RF out = 27dBm 1.6W @ RF out = 23dBm 0.15W in idle mode -10 °C to +55 °C (W)25 x (L)25 x (H)6 mm (1.0 x 1.0 x 0.2 inch ) 5g Tab. 2.1: Quark Up R1270 Technical Specifications Warning: The RF settings must match the country/region of operating to comply with local laws and regulations. It is not allowed the use in different countries/regions from the one in which the device has been sold. 12 Quark Up R1270 - R1270CEVB - Technical Information Manual External Connections The location of the connectors is shown in Fig. 2.1. Their mechanical specifications are listed below: Antenna Port: U.FL female (P.N. HIROSE: U.FL-R-SMT-1(10)). Supply and I/O connector: Molex P.N. 53748-0208 (mates with Molex 52991-0208 to be used on the host board). Fig. 2.1: Quark Up R1270 technical drawings Quark Up R1270 - R1270CEVB - Technical Information Manual 13 1 Supply and I/O connector pinout is shown in the following table : Pin # 10 11 12 13 14 15 16 17 18 19 20 Signal GND TCK GND /RST TXD TMS RXD TDI 5V_USB TDO BSL_SEL TST D+ GPIO0 DGPIO1 VIN GPIO2 VIN GPIO3 Description Ground TCK JTAG signal (debug purpose only) Ground Reset UART TX to host TMS JTAG signal (debug purpose only) UART RX from host TDI JTAG signal (debug purpose only) USB Vbus voltage TDO JTAG signal (debug purpose only) Bootloader interface selection TST JTAG signal (debug purpose only) USB data + General Purpose IO #0 USB data General Purpose IO #1 Input supply voltage General Purpose IO #2 Input supply voltage General Purpose IO #3 Tab. 2.2: Quark Up R1270 connector pinout The GPIO0-GPIO3 pins are 4 general purpose bidirectional pins, their default direction at power up (or after a Reset) is input. The reader can be controlled via UART or USB interface. The selection of the interface is performed internally to the module according to the following algorithm: if no interface has been previously selected and a high level signal is detected on the RXD pin, the UART interface is selected and the USB interface is disabled; on the contrary if no interface has been previously selected and RXD pin is at low level or left unconnected, the USB interface is selected and the UART interface is disabled. Please note that in case you want to switch between the two interfaces you have to reset the module. For the USB interface a Virtual COM Port (VCP) is implemented. To establish a link with the device using UART or VCP connection, you must configure your COM port as follows: Baud rate: 115200 Parity: None Data bits: Stop bits: Flow Control: none JTAG pins, unless otherwise noted, are for internal debug purpose only and shall not be connected by the user. /RST and BSL_SEL pins shall be properly driven to start the bootloader of R1270 embedded microcontroller in case the user wants to upgrade the firmware image of the reader. In normal operation BSL_SEL shall be at low level or left unconnected. See § BLS operation pag. 20 for the description of the bootloader operation. Debug purpose and unused pins should not be connected. 14 Quark Up R1270 - R1270CEVB - Technical Information Manual R1270 supply and I/O connector electrical characteristics2 Pin name Pin No. GND 1,3 TCK Parameter Min VIL VIH Type Max Unit -0.3 0.75 1.5 3.6 10 μA Input current /RESET TXD VIL -0.3 0.6 VIH 1.65 3.6 Internal pull-up resistance 47 Pulse width 10 μs VOL 0.55 VOH 2.5 3.5 3.0 mA Output current TMS VIL -0.3 0.75 VIH 1.5 3.6 10 μA Input current RXD VIL -0.3 0.75 VIH 1.5 3.6 10 μA Input current TDI VIL -0.3 0.75 VIH 1.5 3.6 10 μA 5.25 20 mA Input current 5V_USB TDO 10 Input DC voltage 4.75 5.00 Input current VOL 0.55 VOH 2.5 3.5 3.0 μA Output current BSL_SEL 11 VIL -0.3 1.0 VIH 2.2 3.6 Internal pull-down resistance TST D+,D- GPIO[0:3] 12 13,15 14, 16, 18, 20 10 kΩ VIL -0.3 0.75 VIH 1.5 3.6 Internal pull-down resistance 45 VOL 0.3 VOH 2.8 3.6 Impedance 28 44 Ω VOL 0.55 VOH 2.5 3.5 3.0 mA Output current kΩ VIL -0.3 0.75 VIH 1.5 3.6 10 μA Input current kΩ Exceeding maximum values reported in the table may cause permanent damage to the model. Quark Up R1270 - R1270CEVB - Technical Information Manual 15 Pin name VIN Pin No. 17,19 Parameter Min Type Max Unit Input supply voltage 4.75 5.00 5.25 Supply current (idle) 30 mA Supply current (RF ON @ 23dBm) 0.32 Supply current (RF ON @ 27dBm) 0.55 Tab. 2.3: Quark Up R1270 supply and I/O connector electrical characteristics Power supply connection In the following schematic suggested R1270 power supply connection is shown. An external 100uF bypass capacitor between Vin and GND is recommended for proper operation. The use of fuse F1 (or an equivalent solid state current limiter) is recommended since R1270 doesn't provide internal current limitation protection. Quark Up Module Fig. 2.2: Quark Up R1270 power supply connection External 100uF bypass capacitor between Vin and GND is recommended for proper operation. 16 Quark Up R1270 - R1270CEVB - Technical Information Manual General purpose I/O connections The GPIO0-GPIO3 pins are 4 general-purpose bidirectional pins. Their default direction after a power on reset or a general reset is set to input. GPIO, when configured as Outputs, can be used to drive indicators as leds or buzzers or to send trigger signal to others equipments. GPIO, when configured as Inputs, can accept control signals from other equipments or trigger signals from sensors (i.e. photocells). In the following schematic an example of application of GPIO is shown. Quark Up Module Fig. 2.3: Quark Up R1270 GPIO connection example External reset R1270 manual reset can be performed by forcing at low level /RESET pin for 10μs at least. /RESET pin is pulled-up by an internal resistor. Quark Up Module Fig. 2.4: Quark Up R1270 external reset Quark Up R1270 - R1270CEVB - Technical Information Manual 17 UART connection The RXD/TXD pins are used to communicate with the R1270 board via UART port. Since Quark Up RX/TX are TTL level signals, in order to connect it with a PC, a TTL/RS232 translator shall be used (please refer to the diagram below). To establish a link with the device, the host COM port shall be configured as follows: Baud rate: 115200 Parity: None Data bits: Stop bits: Flow Control: none Quark Up Module Fig. 2.5: Quark Up R1270 RS232 connection 18 Quark Up R1270 - R1270CEVB - Technical Information Manual USB connection In the following image the connection between R1270 module and USB interface is shown. Since the maximum supply current for the reader exceeds the USB limitation (500mA), the supply voltage shall be provided via an external power source or via a dual USB cable. The 5V_USB signal at pin 9 of reader connector is not intended to supply the module but is used by the reader to detect the presence of an USB host. Fig. 2.6: Quark Up R1270 USB connection A Virtual COM Port is implemented, in order to establish a link with the device, the host COM port shall be configured as follows: Baud rate: 115200 Parity: None Data bits: Stop bits: Flow Control: none The VID/PID combination that identifies the USB device is: VID: 21E1 PID: 0080 Antenna port specifications In the following table the pinout of R1270 antenna is shown. Pin # INNER OUTER Function RF OUT GND Direction OUT Description RF output Ground Tab. 2.4: RF port pinout Parameter RF output power Min 10 10 Output power vs. power setting accuracy RF port impedance Recommended antenna VSWR Typ. Max 500 27 ±1 50 2:1 Unit mW dBm dB Ω Tab. 2.5: RF port electrical characteristics Quark Up R1270 - R1270CEVB - Technical Information Manual 19 Reader – Tag Link Profiles Quark Up reader supports different modulation and return link profiles according to EPC Class1 Gen2 protocol. In the following table are reported all profiles that have been tested for the compliance with ETSI and FCC regulations. Link profile # Regulation ETSI - FCC ETSI - FCC ETSI - FCC Modulation PR–ASK; f=40kHz PR–ASK; f=40kHz PR–ASK; f=40kHz Return Link FM0; f = 40kHz Miller (M=4); f = 256kHz Miller (M=4); f = 320kHz Tab. 2.6: Quark Up R1270 reader to tag link profiles Firmware Upgrade Quark Up reader firmware upgrade is based on Boot Start Loader (BSL) of the embedded microcontroller inside the module. An upgrade software has been developed to be used with Quark Up evaluation board (mod. R1270CEVB). BSL operation In order to start the BSL of Quark Up internal microcontroller /RST and BSL_SEL signal shall be driven as in the picture below: Fig. 2.7: BSL sequence The BSL program execution starts if after a reset (or at power up) the BSL_SEL pin is at high level for at least 100ms. The selected interface for upgrade operation is the USB and the protocol applied is defined as: • HID protocol with one input endpoint and one output endpoint. Each endpoint has a length of 64 bytes. • VID: 0x2047 • PID: 0x0200 Default value. 20 Quark Up R1270 - R1270CEVB - Technical Information Manual Firmware upgrade via R1270CEVB board Quark Up firmware upgrade can be managed via USB by using the evaluation board (mod.R1270CEVB) and the SW upgrade program. The Quark Up Upgrade Tool is available for free at Quark Up R1270 web page of the CAEN RFID Web Site, SW/FW section. In order to upgrade the firmware follow the steps described below: 1. Connect to the USB port the evaluation board with the Quark Up reader installed. 2. Press the reset switch on the evaluation board (SW3). 3. With SW3 pressed, press the BSL_SEL switch on the evaluation board (SW2). 4. Release SW3. 5. Release SW2 within 1s respect to SW3. 6. Open the FW upgrade program. 7. Click on Next button. 8. In the window you will see the message “Found 1 device” (if the message is “No device connected” repeat the points 2,3, 4 and 5). Quark Up R1270 - R1270CEVB - Technical Information Manual 21 22 9. Select the FW image file by clicking on “Browse” button. 10. Click on “Upgrade Firmware” button and wait for the upgrade to be completed. 11. At the end of procedure, if the upgrade has been successfully performed, you will see the messages reported in the image below and the module is ready for normal operation. Quark Up R1270 - R1270CEVB - Technical Information Manual PCB Pad Layout In the picture below the recommended PCB pad layout to be implemented on the user host board is shown. The 3 square pads shall be used to solder R1270 shield and shall be connected to ground. In addition it is shown the position and the layout required for Molex 52991-0208 connector, which mates with R1270 supply and I/O connector, and which shall be soldered on the host board. 19 20 Fig. 2.8: PCB pad layout Quark Up R1270 - R1270CEVB - Technical Information Manual 23 3 Quark Up R1270CEVB This Chapter provides the basic information to work with the Quark Up R1270CEVB Evaluation Board. It contains these topics: 24 Technical Specifications Table Connection diagram Installation Notice Technical drawings Electrical scheme External Connections Installing the USB Virtual COM port driver Quark Up R1270 - R1270CEVB - Technical Information Manual Technical Specifications Table Switch USB Port User Interface Dimensions Electrical Power Operating Temperature SW1= GPIO SW2= BSL_SEL SW3= RESET Mini USB Type A plug connector Bus powered USB 2.0 device Must be connected to two High-power Port (500 mA @ VBUS) with a dual USB cable. It appears as USB serial port Virtual Com Port (VCP) drivers for Windows XP/Vista/Seven (7) Baudrate: 115200 Databits: 8 Stopbits: 1 Parity: none Flow control: none Red LED: Power Green LED: GPIO[0..3]. (W)38.0 x (L)76.0 x (H)12.0 mm (1.5 x 3.0 x 0.5 inch ) DC Voltage 5V +/-5% Max 800 mA -10 °C to +55 °C Tab. 3.1: R1270CEVB - Quark-Up Reader Evaluation Board Connection diagram The following block diagram shows how to connect the Mod. R1270 with the PC host via the Mod. R1270CEVB evaluation board. to host Antenna R1270CEVB Molex Connector USB R1270 Ultra Compact Embedded UHF RFID Reader You can download VCP drivers for Windows based systems from the CAEN RFID Web Site at Quark Up R1270 page. With Quark Up reader operating. Quark Up R1270 - R1270CEVB - Technical Information Manual 25 Installation Notice Refer to § Installation Notice pag. 10 for the correct way to connect the Quark Up R1270 module to the evaluation board. Technical drawings The location of the connectors is shown in Fig. 3.1. Their mechanical specifications are listed below. All dimensions are in millimeters. Fig. 3.1: Quark Up R1270CEVB technical drawing 26 Quark Up R1270 - R1270CEVB - Technical Information Manual Electrical scheme The electrical scheme of the Quark Up R1270CEVB is shown in Fig. 3.2: Quark Up R1270CEVB electrical scheme. The board hosts an embedded DC/DC boost converter that is used to compensate voltage drop across USB cable. This circuit can be used as a reference design for standard 3.7V battery applications. Fig. 3.2: Quark Up R1270CEVB electrical scheme Quark Up R1270 - R1270CEVB - Technical Information Manual 27 External Connections GPIO connector pinout (J5) is shown in the following table: Pin # Signal GPIO 1 GPIO 0 GPIO 2 GPIO 3 GND GND Tab. 3.2: Quark Up R1270CEVB GPIO connector pinout J4 (not populated) is the JTAG connector for internal debug purposes and shall not be used. In case an OEM manufacturer wants to connect the module to its own device for testing purposes, SMT pads are present on the bottom side of the board for power supply, UART and USB signals. Pad # P1 P2 P3 P4 P5 P6 Signal RXD TXD D+ DVin (2.5Vdc ÷ 4.5Vdc) GND Tab. 3.3: Quark Up R1270CEVB SMT pads signals Fig. 3.3: Quark Up R1270CEVB SMT pads 28 Quark Up R1270 - R1270CEVB - Technical Information Manual Installing the USB Virtual COM port driver Connect the Quark Up R1270 reader to the evaluation board (see § Installation Notice pag. 10) and then to a PC using the provided USB cable. A dialog window appears informing you that the device is not recognized and you should be prompted for inserting the R1270 Quark Up USB driver (download the driver at Quark Up R1270 web page, SW/FW section) in order to correctly operate with the reader. After installing the driver, the reader is detected by the PC as an emulated serial port (VCP): Quark Up R1270 - R1270CEVB - Technical Information Manual 29 4 Quark Up Regulatory Compliance This Chapter gives information on the Quark R1230CB Reader Regulatory Compliance. It contains these topics: 30 FCC Compliance Quark Up R1270 - R1270CEVB - Technical Information Manual FCC Compliance This equipment has been tested and found to comply with Part 15 of the FCC Rules. NOTE: a. Any changes or modification not approved by CAEN RFID could void the user’s authority to operate the equipment. b. The Quark Up R1270 Module, which is rated at 500 mW output, is approved for operation with the QUAD Circular Polarized Quadrifilar Antenna (CAEN RFID mod. WANTENNAX010) with 0.7dBi gain. Use of other than the approved antennas with this unit may result in harmful interference with other users, and cause the unit to fail to meet regulatory requirements. c. This transmitter module is authorized to be used in other devices only by OEM integrators under the following conditions: 1. The RFID Module antenna shall have a separation distance of at least 20 cm from all persons 2. The transmitter module must not be co-located with any other antenna or transmitter d. In case that the two conditions above are met, further transmitter testing will not be necessary. However, the OEM integrator is still responsible for testing the end-product for any additional compliance requirements required with this module installed (for example, digital device emissions, PC peripheral requirements, etc.). In the event that these conditions can not be met (for certain configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In such case the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization. e. If the FCC ID is not visible when the module is installed inside another device, the OEM integrator shall apply a label in a visible area on his product with the following statement: Contains Transmitter Module FCC ID: UVECAENRFID015 or Contains FCC ID: UVECAENRFID015 f. The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module or change RF related parameters in the user manual of the end product. Quark Up R1270 - R1270CEVB - Technical Information Manual 31
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 31 Language : it-IT Tagged PDF : Yes Title : R1230CB Author : manuela Subject : 00107/05:A828x.MUTx/09 Keywords : 1.5 Creator : Microsoft® Word 2010 Create Date : 2014:07:29 10:11:44+02:00 Modify Date : 2014:07:29 10:11:44+02:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools