CIG 140W G-140W-C User Manual

CIG SHANGHAI CO., LTD. G-140W-C Users Manual

User Manual_1.pdf

       G-140W-C User Manual
   - 1 -  1   Precautions Please  read the user  manual  before installation and operation  of the device. Please keep the User Manual for future reference. 1.1 Installation Precautions   The device should only be installed by qualified personnel.  Please check the voltage rating before connecting the power. It is recommended not to share the same power socket with other high power-rated devices (examples: Hairdryer, Refrigerator, Iron).  Do not place the device in the vicinity of flammable or conductive materials, high temperature (direct sunlight), moisture, or other appliances that produce heat.  Always make sure the device is properly ventilated, do not place any objects on the device to avoid overheating.  Ensure the device is installed on an even surface.  The power socket and power cable shall be inspected regularly and replaced in case ofdamage to avoid risk of electric shock or fire. 1.2 Operation Precautions    Do not attempt to repair the device in any occasion. Improper disassembly of the device may expose you to electric components and may cause shock or other risks. Please contact your service provider if there are problems with the device.    Unplug the power before cleaning equipment. Use a soft and dry cloth to clean the equipment.Avoid the use of liquid or aerosol.  Prevent liquid spillage on the device to avoid short circuit.   Ensure a proper environment for the device to avoid overheating; do not block the device ventilation outlet.  Please contact the Service Provider if you are in doubt in on how to connectother electronic devices to the ONT to avoid possible damage to the devices.
   - 2 -  1.3   Laser Safety  Only qualified service personnel who are extremely familiar with laser radiation  hazards should  install or  remove the fiber  optic  cables and fiber related units in this system.  There may be invisible laser radiation at the fiber optic cable when the cable is removed from the connector. Avoid direct exposure to the laser beam  Notethe following danger with regards to laser safety: Eyes can be damaged when they are exposed to a laser beam. Take necessary precautions before you plug in the optical modules.  Do not bend the cables to a diameter of less than 7.5 cm as this may damage the fiber or reducethe normal optical signal strength.  The ONT is classified as a Class 1 laser product based on its transmit optical output.
   - 3 -  2   Introduction  G-140W-C  is  a  convenient,  flexible,  standard  compliant  and  highly integrated GPON Optical Network Termination (ONT) device. It can be used  in  residential,  Small  Office  Home  Office  (SOHO)  and  enterprise environment providing a highly reliable broadband service.   G-140W-C  is  equipped  with  a  ITU-T  G.984  compliant  GPON  optical interface, and provides the following user interfaces:  Four auto sensing 10/100/1000M Ethernet interfaces for high-speed Internet access and IPTV or Video on Demand (VOD) service  One voice (VoIP) service port  Two USB ports  2.4G(802.11b/g/n) WIFI  5 GHz(802.11ac) WIFI 2.1   Features G-140W-CProduct Features:  Support for multiple simultaneous users  Advanced VLAN Bridge,supportinga variety of operating modes  Support for WEB configurable ONU authentication password  Supports traffic classification and powerful QoS features to meet the needs of different residential or business services  Support USB devices to plug in.  Support 2.4G 802.11b/g/n wireless adapter to associate  Support 5G 802.11ac wireless adapter to associate  2.2   Product Specifications   Environmental Requirements Ambient Temperature:-5C~+45C Humidity: 10%  to 90% (non-condensing)  Power Specifications Input:AC100 ~240V/50~60Hz Output:DC12V,1.5A  Power consumption:<18W
   - 4 -  3   Installation 3.1    Hardware Description 3.1.1   Front Panel   LED Description: LED Color Status Description POWER  Off Power off Green Solid Power on Green Blinking ONTself-test failed LINK  Off GPON  is  down  or  no  link connected Green Solid GPON link between  ONT and OLT is operating normally LOS  Off ONU is NOT authorized Red Off Optical  signal  is  present  on GPON Link Red Solid Optical  signal  is  not  present on GPON link LAN1-4  Off ONT  power  off  or  Ethernet not connected Green Solid Ethernet is linked Green Flashing Ethernet  link  is  active  and data is transmitted/received TEL  Off No Service Green Solid On Hook Green Flashing Call in or talking WPS 2.4G/ 5G  Off WPS disabled Green  Solid  WPS success  WLAN 2.4G  Off Wireless  is  down  or  no  link connected
 - 5 - Green Solid Wireless enabled Green Flashing Traffic on wireless interface WLAN 5G  Off Wireless  is  down  or  no  link connected Green Solid Wireless enabled Green Flashing Traffic on wireless interface USB 1,2  Off No device connected Green Solid At  least  one  USB  device  is connected Green flashing Traffic activity on at least on USB device INTERNET  Off connection  not  present  or device in bridged  mode  with  no  IP address Green Solid HSI WAN is connected: a) the device  has  an  IP  address assigned from IPCP, DHCP, or  static,  and  no  traffic  has been detected; b) the session is dropped due to idle timeout  but  the  PON  link  is still present. Green Flashing PPPoE or DHCP connection in progress or traffic present  3.1.2 Rear Panel and Side    Rear Panel and Side Buttons: Port / Button Description TEL RJ-11 FXSPort: Connect Phone or Fax to provide voice service
 - 6 - LAN1/2/3/4 RJ-45 10/100/1000M  Ethernet  Port:  Connect  Local Network device (PC, STB) RESET Factory Resetbutton. Press and hold the button for 10 seconds or more to restore the device to the factory defaults. WPS This button turnsWIFI WPS on. WLAN This button turnsWIFIon or off POWER Power connector.Used to connect the external power adapter ON/OFF Power On/Off OPTICAL SC/APC Fiber Optic connector for PON Interface LED 1st press: Power LED is solid Green. Turn off the other LEDs. 2nd press: turn on all LEDs (back to normal)    3.2 Hardware Installation 3.2.1   Mounting the G-140W-Cindoor ONT on the desk  allow a minimum 100 mm clearance above the top cover allow a minimum 50 mm clearance from the side vents do not place any heat source directly above the top cover or belowthe bottom cover  3.3  Cable Connections and Login    RJ45Ethernet Interfaces (LAN1/2/3/4)  Connect the computer network interface or other network devices (such as Ethernet switch, IPTV Set-Top-Box) to the Ethernet LAN ports of the G-140W-Cusing a RJ45 cable. The 4 LAN ports are 10/100/1000M Ethernet interface. It auto senses the Ethernet interface speed to 10Mbps, 100Mbps or 1000Mbps.     RJ11 Voice Interface(TEL)  Connect the telephone set or Fax machine to the TEL ports of the G-140W-Cusing a RJ11 cable. The TEL1 ports are FXS interfaces providing services to voice and/or fax devices.  PON Broadband Interface (OPTICAL)
 - 7 - Connect the Fiber Interface point provided by the Broadband Internet Services Provider to the OPTICAL port of the G-140W-Cusing a single mode fiber optics cable with a SC/APC connector. There is a cover to protect the optical port. Remove the cover before making the connection.  Power Interface (POWER)  Connect the power adapter provided in the package to the POWER connector of the G-140W-C. Connect the power adapter to the power socket. Press the ON/OFF button. Ensure the power LED indicator is on.   Login to the WEB Graphical User Interface  IP address: 192.168.1.1 User name:  admin Password: admin  3.4  Troubleshooting  Problem Possible Solutions POWER LED is off Check if the power on/off button is in the ON position Check if the power adapter is properly connected to the G-140W-C LINK LED is off Check if the fiber optic cable is properly connected at both ends LAN1-4 LED is off Check if proper RJ45 Ethernet cable is used Check if the RJ45 cable is properly connected at both ends Check if the network interface on the computer or network device is functioning properly TEL1 LED is off Check if the RJ11 cable is properly connected at both ends Check if the telephone set is in off hook status  WPS LED is red Check if the button is pushed and the wireless adapter’s WPS button is also pushed. WLAN LED is off Check if the WLAN is properly disabled on web GUI or the WLAN button is pushed.
 - 8 - 4 Hazardous Substances    Parts Hazardous Substance Pb Hg Cd Cr6+ PBB PBDE Circuit Modules × ○ × ○ ○ ○ Cables & Cable Assemblies × ○ ○ ○ ○ ○ Metal Parts × ○ ○ ○ ○ ○ Plastic and Polymeric parts ○ ○ ○ ○ ○ ○ ○:Indicates that the concentration  of  the  hazardous substance in all homogeneous materials  in  the  parts  is  below  the  relevant  threshold  of  the  SJ/T11363-2006 standard. ×: Indicates that the concentration of the hazardous substance of at least one of all homogeneous  materials  in  the  parts  is  above  the  relevant  threshold  of  the SJ/T11363-2006 standard.  This  table  shows  where  these  substances  may  be  found  in  the  supply  chain  of NokiaElectronic information products, as of the date of sale of the enclosed product. Note  that  some  of  the  component  types  listed  above  may  or  not  be  a  part  of theenclosed product.           The Environment-Friendly Use Period (EFUP) for all enclosed products and  their parts are per the symbol shown here, unless otherwise marked. Certain  parts may have a different EFUP (for example, battery modules) and so are  marked to reflect such. The Environment-Friendly Use Period is valid only  when the product is operated under the conditions defined in the product manual.
 - 9 - Federal Communications Commission (FCC) Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generate, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:    Reorient or relocate the receiving antenna.   Increase the separation between the equipment and receiver.   Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   Consult the dealer or an experienced radio/TV technician for help.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This device must not be collocated or operating in conjunction with any other antenna or transmitter.  RF exposure warning This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body