User Manual_1.pdf
G-140W-C User Manual 1 Precautions Please read the user manual before installation and operation of the device. Please keep the User Manual for future reference. 1.1 Installation Precautions The device should only be installed by qualified personnel. Please check the voltage rating before connecting the power. It is recommended not to share the same power socket with other high power-rated devices (examples: Hairdryer, Refrigerator, Iron). Do not place the device in the vicinity of flammable or conductive materials, high temperature (direct sunlight), moisture, or other appliances that produce heat. Always make sure the device is properly ventilated, do not place any objects on the device to avoid overheating. Ensure the device is installed on an even surface. The power socket and power cable shall be inspected regularly and replaced in case ofdamage to avoid risk of electric shock or fire. 1.2 Operation Precautions Do not attempt to repair the device in any occasion. Improper disassembly of the device may expose you to electric components and may cause shock or other risks. Please contact your service provider if there are problems with the device. Unplug the power before cleaning equipment. Use a soft and dry cloth to clean the equipment.Avoid the use of liquid or aerosol. Prevent liquid spillage on the device to avoid short circuit. Ensure a proper environment for the device to avoid overheating; do not block the device ventilation outlet. Please contact the Service Provider if you are in doubt in on how to connectother electronic devices to the ONT to avoid possible damage to the devices. -1- 1.3 Laser Safety Only qualified service personnel who are extremely familiar with laser radiation hazards should install or remove the fiber optic cables and fiber related units in this system. There may be invisible laser radiation at the fiber optic cable when the cable is removed from the connector. Avoid direct exposure to the laser beam Notethe following danger with regards to laser safety: Eyes can be damaged when they are exposed to a laser beam. Take necessary precautions before you plug in the optical modules. Do not bend the cables to a diameter of less than 7.5 cm as this may damage the fiber or reducethe normal optical signal strength. The ONT is classified as a Class 1 laser product based on its transmit optical output. -2- Introduction G-140W-C is a convenient, flexible, standard compliant and highly integrated GPON Optical Network Termination (ONT) device. It can be used in residential, Small Office Home Office (SOHO) and enterprise environment providing a highly reliable broadband service. G-140W-C is equipped with a ITU-T G.984 compliant GPON optical interface, and provides the following user interfaces: Four auto sensing 10/100/1000M Ethernet interfaces for high-speed Internet access and IPTV or Video on Demand (VOD) service One voice (VoIP) service port Two USB ports 2.4G(802.11b/g/n) WIFI 5 GHz(802.11ac) WIFI 2.1 Features G-140W-CProduct Features: Support for multiple simultaneous users Advanced VLAN Bridge,supportinga variety of operating modes Support for WEB configurable ONU authentication password Supports traffic classification and powerful QoS features to meet the needs of different residential or business services Support USB devices to plug in. Support 2.4G 802.11b/g/n wireless adapter to associate Support 5G 802.11ac wireless adapter to associate 2.2 Product Specifications Environmental Requirements Ambient Temperature:-5C~+45C Humidity: 10% to 90% (non-condensing) Power Specifications Input:AC100 ~240V/50~60Hz Output:DC12V,1.5A Power consumption:<18W -3- Installation 3.1 Hardware Description 3.1.1 Front Panel LED Description: LED POWER Color Status Off Power off Green Solid Power on Green Blinking Off LINK Green Solid Off LOS Red Off Red Solid Off LAN1-4 WPS 2.4G/ 5G WLAN 2.4G ONTself-test failed GPON is down or no link connected GPON link between ONT and OLT is operating normally ONU is NOT authorized Optical signal is present on GPON Link Optical signal is not present on GPON link ONT power off or Ethernet not connected Green Solid Green Flashing Green Solid Green Flashing Off WPS disabled Green Solid WPS success Off TEL Description Off -4- Ethernet is linked Ethernet link is active and data is transmitted/received No Service On Hook Call in or talking Wireless is down or no link connected Green Solid Green Flashing Off WLAN 5G Green Solid Green Flashing Off USB 1,2 Green Solid Green flashing Off INTERNET 3.1.2 Green Solid Green Flashing Wireless enabled Traffic on wireless interface Wireless is down or no link connected Wireless enabled Traffic on wireless interface No device connected At least one USB device is connected Traffic activity on at least on USB device connection not present or device in bridged mode with no IP address HSI WAN is connected: a) the device has an IP address assigned from IPCP, DHCP, or static, and no traffic has been detected; b) the session is dropped due to idle timeout but the PON link is still present. PPPoE or DHCP connection in progress or traffic present Rear Panel and Side Rear Panel and Side Buttons: Port / Button TEL Description RJ-11 FXSPort: Connect Phone or Fax to provide voice service -5- LAN1/2/3/4 RESET WPS WLAN POWER ON/OFF OPTICAL LED RJ-45 10/100/1000M Ethernet Port: Connect Local Network device (PC, STB) Factory Resetbutton. Press and hold the button for 10 seconds or more to restore the device to the factory defaults. This button turnsWIFI WPS on. This button turnsWIFIon or off Power connector.Used to connect the external power adapter Power On/Off SC/APC Fiber Optic connector for PON Interface 1st press: Power LED is solid Green. Turn off the other LEDs. 2nd press: turn on all LEDs (back to normal) 3.2 Hardware Installation 3.2.1 Mounting the G-140W-Cindoor ONT on the desk allow a minimum 100 mm clearance above the top cover allow a minimum 50 mm clearance from the side vents do not place any heat source directly above the top cover or belowthe bottom cover 3.3 Cable Connections and Login RJ45Ethernet Interfaces (LAN1/2/3/4) Connect the computer network interface or other network devices (such as Ethernet switch, IPTV Set-Top-Box) to the Ethernet LAN ports of the G-140W-Cusing a RJ45 cable. The 4 LAN ports are 10/100/1000M Ethernet interface. It auto senses the Ethernet interface speed to 10Mbps, 100Mbps or 1000Mbps. RJ11 Voice Interface(TEL) Connect the telephone set or Fax machine to the TEL ports of the G-140W-Cusing a RJ11 cable. The TEL1 ports are FXS interfaces providing services to voice and/or fax devices. PON Broadband Interface (OPTICAL) -6- Connect the Fiber Interface point provided by the Broadband Internet Services Provider to the OPTICAL port of the G-140W-Cusing a single mode fiber optics cable with a SC/APC connector. There is a cover to protect the optical port. Remove the cover before making the connection. Power Interface (POWER) Connect the power adapter provided in the package to the POWER connector of the G-140W-C. Connect the power adapter to the power socket. Press the ON/OFF button. Ensure the power LED indicator is on. Login to the WEB Graphical User Interface IP address: 192.168.1.1 User name: admin Password: admin 3.4 Troubleshooting Problem POWER LED is off LINK LED is off LAN1-4 LED is off TEL1 LED is off WPS LED is red WLAN LED is off Possible Solutions Check if the power on/off button is in the ON position Check if the power adapter is properly connected to the G-140W-C Check if the fiber optic cable is properly connected at both ends Check if proper RJ45 Ethernet cable is used Check if the RJ45 cable is properly connected at both ends Check if the network interface on the computer or network device is functioning properly Check if the RJ11 cable is properly connected at both ends Check if the telephone set is in off hook status Check if the button is pushed and the wireless adapter’s WPS button is also pushed. Check if the WLAN is properly disabled on web GUI or the WLAN button is pushed. -7- 4 Hazardous Substances Parts Circuit Modules Cables & Cable Assemblies Metal Parts Plastic and Polymeric parts Hazardous Substance Pb × Hg ○ Cd × Cr6+ ○ PBB ○ PBDE ○ × ○ ○ ○ ○ ○ × ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ :Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ/T11363-2006 standard. ×: Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ/T11363-2006 standard. This table shows where these substances may be found in the supply chain of NokiaElectronic information products, as of the date of sale of the enclosed product. Note that some of the component types listed above may or not be a part of theenclosed product. The Environment-Friendly Use Period (EFUP) for all enclosed products and their parts are per the symbol shown here, unless otherwise marked. Certain parts may have a different EFUP (for example, battery modules) and so are marked to reflect such. The Environment-Friendly Use Period is valid only when the product is operated under the conditions defined in the product manual. -8- Federal Communications Commission (FCC) Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generate, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This device must not be collocated or operating in conjunction with any other antenna or transmitter. RF exposure warning This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body -9-
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 10 Language : zh-CN Tagged PDF : Yes Title : 产品说明书 Author : ronghais Creator : Microsoft® Office Word 2007 Create Date : 2018:03:05 14:15:24 Modify Date : 2018:03:05 14:15:24 Producer : Microsoft® Office Word 2007EXIF Metadata provided by EXIF.tools