COMMAX DRC500LCRF MAIN ENTRANCE CAMERA WITH 13.56MHz RFID User Manual DRC 481L DRC 500L
COMMAX Co., Ltd. MAIN ENTRANCE CAMERA WITH 13.56MHz RFID DRC 481L DRC 500L
COMMAX >
USERS MANUAL
Main Entrance Camera (Common Method) Model No. DRC-481L(C)/RF DRC-500L(C)/RF DRC-481L DRC-500L -Feature• • • • 8-wire Common Method (Interphone) 4-wire Common Method (Videophone) RF/ID Feature (Optional) Surveillance Monitor Support T hank you for purchasing our C OMMAX product. P lease carefully read this UserÕs G uide (in particular, precautions for safety) before using the product and follow the instructions to use your productexactly. T he company is not responsible for any safety accidents caused in abnormal operation of the product. DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지2 Class B device NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. -Increase the se paration between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. [ CAUTION ] Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user's authority to operate the equipment. [FCC compliance Information] This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received. Including interference that may cause undesired operation. [FCC WARNING] This equipment may generate or use radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modification is made. Table of Contents 1. Greetings …………………………………………………………………………… 4 2. Before Getting Started …………………………………………………………… 4 3. Overview …………………………………………………………………………… 5 4. PIN Types ………………………………………………………………………… 10 5. Setting PIN ………………………………………………………………………… 11 6.Household PIN Confirmation ……………………………………………………… 14 7.Configuring Building and Serial Numbers in the Main Entrance Interphone ……… 15 8. Using Remote Cardkeys (RF/ID) - Optional ……………………………………… 17 9. Surveillance Monitor Configuration ……………………………………………… 23 10. Door Release Time Setup ………………………………………………………… 24 11. Page Tone Selection ……………………………………………………………… 25 12. Wiring Method Selection ………………………………………………………… 26 13. Video Out Impedance Adjustment ……………………………………………… 27 14. Household Interphone Diagnosis ………………………………………………… 28 15. Household Number Registration ………………………………………………… 30 16. Paging the Household …………………………………………………………… 32 17. Paging the Guardhouse …………………………………………………………… 32 18. Door Release Using the Household PIN ………………………………………… 33 19. Door Release Using the Building (Management) PIN …………………………… 33 20. Appendix (Various Program Summaries) ……………………………………… 34 21. Wiring Method …………………………………………………………………… 36 22. Specifications …………………………………………………………………… 51 - 1- DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지2 Safety Warning & Caution Please follow the things described below in order to prevent any danger or property damage. Prohibition. Warning It may cause a serious damage or injury if violated. No disassembly No touch Must follow strictly. Caution Shows plugging out the power cord without an exception It may cause a minor damage or injury if violated. Shows the warning and caution for an electric shock. Shows the warning and caution for a fire. Power & Installation Warning Please don’t use several products at the same time on one power socket. ·It may cause a fire due to an abnormal overheating. Please don’t bend the power cable excessively or it may cause an electric shock. ·fire when using a damaged power cable. Please don’t handle the power cable with a wet hand. ·It may cause an electric shock. Please plug out the power cable from the socket when not using it for a long period of time. ·It may shorten the product lifespan or cause a fire. Please don’t install the product in the place where there is much oil, smoke or humidity. ·It may cause an electric shock or fire. Please don’t install the product with the lightening and thunder. ·It may cause an electric shock or fire. Please don’t use and connect this product with other products with different rated voltage ·It may cause a disorder or fire. When installing the product that generates heat, please install the product away from the wall (10cm) for the ventilation. ·It may cause a fire due to the increased internal temperature. - 2- DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지3 Cleaning & Use Warning Please don’t disassemble, repair or rebuild this product arbitrarily (please contact the service center if a repair is needed. ·It may cause an electric shock or fire. If an abnormal sound, burning smell or smoke is coming out of the product, please plug out the power cable and contact a service center. ·It may cause an electric shock or fire. Please don’t insert any metallic or burnable materials into the ventilation hole. ·It may cause an electric shock or fire. Please use only the designated batteries for the products of using DC power. ·It may cause an electric shock or fire. Cleaning & Use Power & Installation Caution Please plug the power cable firmly into the inner end ·It may cause a fire. Please hold the plug tightly when unplugging the power cable (a part of the copper wire may be disconnected if the grabbing is only made on the cord when pulling out the cable). ·It may cause an electric shock or fire When connecting the power cables after cutting the cable, please install the product with power off ·It may cause an electric shock or fire When installing the product, please fix it firmly while using the wall-mounting unit and screws. ·It may cause an injury from the falling object. Please be careful when using an AC circuit breaker since there is a possibility of an electric shock. Please check the use voltage and current for the DC-only products and use the appropriate rectifier. ·It may cause a fire. Please avoid direct rays of the sun or heating devices at a time of installation. ·It may cause a fire. Please don’t install the product on an unstable place or small support board. ·It may cause an injury if it falls down while in use. When cleaning the product, please rub it with a soft and dry cloth after plugging out the power cable. (Please don’t use any chemical products such as wax, benzene, alcohol or cleanser.) Please don’t drop the product on the ground and don’t apply a shock . ·It may cause a failure. Please use the designated connection cable within the maximum calling distance designated for the product ·It may reduce the product performance. - 3- DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지4 1. Greetings Thank you for purchasing a Commax product. This product is a high tech Main Entrance interphone that supports electronic and remote (Optional) keys and finger print recognition (Optional) features. Please read this manual carefully. 2. Before Getting Started Using 8-wire common wiring method between the Main Entrance interphone and the Guardhouse interphone, this system supports 3 communication circuits, and each communication circuit is a Balance Type that supports 2 wires. Using 4-wire common wiring method between the Main Entrance interphone and the Household interphone, this system supports telephone and video connections. Only use coaxial cables for video connection. The short and cut of wiring can cause a malfunction. Be sure to check wiring before installation. It is recommended that each Main Entrance interphone is installed and its connection be checked from the Guardhouse and the Household(s). Maximum of 2048 Remote Cardkeys are supported. (When not connected to a computer) Three consecutive entries of wrong Management PIN, Building PIN, or Household PIN will automatically page the Guardhouse. Three consecutive attempts at unlocking doors with an unregistered Remote Cardkey will also automatically page the Guardhouse. ※ Remarks - 4- DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지5 3. Overview 3-1. Feature DRC-481L Description No No Description No Description Display Window (FND) 10 Guard Button 17 Household Interphone (1) RF/ID Receiver (Optional) 11 Cancel Button 18 Household Interphone (2) Speaker 12 Reset Button 19 Video Out Mic 13 Selection Switches 20 Power: DC12V/1A (RF-1A) No. 1: Computer Connection No. 2: Electronic Key Selection (Finger Print Recognition) Key Pad Call Button CCD Camera 14 Infrared Sensor Terminal Program Button 15 Guardhouse Interphone Terminal Electronic Key Button 16 Computer Connection Terminal - 5- 21 Door Release Terminal 22 Receiver Volume Control 23 Security Switch Connection DRC-500L Description No No Description No Description Speaker 10 Night Lamp 19 Security Switch Connection Key Pad 11 Display Window (FND) 20 Power: DC15V/1A(CS-15C) Program Button 12 CCD Camera 21 Reset Button Electronic Key Button 13 Computer Connection Termina 22 Selection Switches Guard Button 14 Guardhouse Interphone Termina Cancel Button 15 Household Interphone (1) Call Button 16 Household Interphone (2) Mic 17 Video Out(Surveillance Monitor Connection) 24 Door Release Terminal RF/ID Receiver (Optional) 18 Infrared Sensor Terminal - 6- No. 1: Computer Connection No. 2: Electronic Key Selection 23 Receiver Volume Control DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지7 3-2. Basic Function RF/ID Receiver (Optional) To open the door using a Remote Cardkey, place the key here. The word‘oPEn’will display and the door will be released. Audio Guide “Door Opened” Please the Card Here OPEN DOOR Call Button (E: Enter) This button is used to page households. Press the Page button after entering the Household Number. Program Button (P: Program ) This button is used to Program. Program Enter Electronic Key Button (K: Key) This button is used to release the door by using PIN. (Available only when the Electronic Key option has been set as OFF. When it is set as ON, Finger Print Recognition is enabled) Guardhouse Page Button (G: Guard) This button is used to page the Guardhouse if the Guardhouse interphone has been installed. - 7- DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지8 Cancel Button (X: Cancel) This button is used to cancel the current operation. Audio Guide “Cancelled” Selection Switches No. 1: Computer Connection Switch (Used for connection with a computer) Connects a computer using network exclusive to DRC-481L. OFF : To connect to a computer via the RS-485 Port with Finger Print Recognition in use. ON : To connect to a computer via an internal network without Finger Print Recognition in Not Connecting to a Computer Connecting to a Computer No. 2: Electronic Key Selection (Finger Print Recognition Switch) OFF: Electronic Key is enabled. (Finger Print Recognition is disabled) ON: Electronic Key is disabled. (Finger Print Recognition is enabled) Using Electronic key Not Using Electronic key Reset Button This button is used to reset the Guardhouse PIN or the Management PIN. If you cannot remember the number of a management office, push the reset button both 12 and 21. Receiver Volume Control Controls the volume in the receiver from LOW to HIGH. To Lower the Volume To Raise the Volume - 8- DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지9 ● Must Know Before Use! 1) Accessing All Features with the Program Button -When an error has been made as indicated by continuous beeps, please cancel and start again from the beginning. Beep-Beep-Beep (Error) Start again from the beginning 2) Forgotten PIN 2-1. Household PIN Use the Household PIN verification feature of 6-1 to retrieve the PIN. (Please inquire to the Guardhouse or the Management Office) 2-2. Building PIN Reenter using the Management PIN. 2-3. Management PIN Press the Reset button. Both the Building and the Management Building PINs are reset to default. 3) 8-5 All Remote Cardkey Deletion is to be used only when the unit is being initially installed. 4) Configuration Mode Indications Configured features are displayed on the Display Window when the Main Entrance interphone is not in use. Version No. Series Camera Impedance Wiring Method Serial Number Building Number - 9- DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지10 4. PIN Types 4-1. Management PIN - This PIN is for use by the person in charge of the Management Office. - By default, this PIN is set as 4321. - For convenience, hereafter management PIN. 4-2. Building PIN - This is the common PIN for each main entrance. - By default, this PIN is set as 1234. - For convenience, hereafter building PIN. 4-2. Household PIN - Each household has its own PIN. - By default, this PIN is set as 1234. - For convenience, hereafter household PIN.P : Program K : Electronic Key Old PIN Default Management PIN: 4321 Default Building PIN: 1234 Default Household PIN: 1234 New PIN New PIN to be set by the user. - 10 - E : Call DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지11 5. Setting PIN 5-1. Management PIN Setup P - Old Management PIN - E - 0 - E - New PIN -E Management PIN must be 4-digits long. 0000 will not be recognized as a valid PIN. Press the Program button (P). Press the Program Number 0. Press the Call button (E). Enter the old PIN 4321. Press the Call button (E). Enter the new PIN. ex)1470 Management PIN has been updated. Press the Call button (E). ① Press the Program button (P).‘Prog’ will appear) ② Enter the old PIN 4321. ③ Press the Call button (E). ④ Press the Program Number 0. ⑤ Press the Call button (E).‘PASS’ will blink) ⑥ Enter the new PIN. ⑦ Press the Call button (E). ⑧ Management PIN has been updated. - 11 - DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지12 5-2. Building PIN Setup P - Old Building PIN - E - 1 - E - New PIN - E Building PIN must be 4-digits long. 0000 will not be recognized as a valid PIN. Press the Program button (P). Press the Program Number (1). Enter the old PIN 1234. Press the Call button (E). Press the Call button (E). Enter the new PIN. ex)2580 Building PIN has been updated. Press the Call button (E). ① Press the Program button (P).‘Prog’ will appear) ② Enter the old PIN 1234. ③ Press the Call button (E). ④ Press the Program Number 1.. ⑤ Press the Call button (E).‘PASS’ will blink) ⑥ Enter the new PIN. ⑦ Press the Call button (E). ⑧ Building PIN has been updated - 12 - DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지13 5-3. Household PIN Setup K - Program Number - E - Household Number - E - Old Household PIN - E - New PIN - P Household PIN must be 4-digits long. 0000 will not be recognized as a valid PIN. This method of Household PIN change may vary depending on household interphone types. (Types that support PIN changing from the household interphone) Electronic Key button (K). Household Number. ex) 101 Press the Call button (E). Press the Program Number (20). Press the Call button (E). Enter the old PIN. ex)1234 Enter the new Household PIN. ex)3690 ① Press the Electronic Key button (K). ② Press the Program Number 20. ③ Press the Call button (E).‘hono’ will blink) ④ Enter the Household Number. ⑤ Press the Call button (E).‘PASS’ will blink) ⑥ Enter the old Household PIN. ⑦ Press the Call button (E).‘PASS’ will blink) ⑧ Enter the new Household PIN ⑨ Press the Program button (P). Household PIN has been updated. - 13 - Press the Call button (E). Press the Program button (P). DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지14 6.Household PIN Confirmation 6-1. Household PIN Confirmation P - Building (Management) PIN - E - Program Number - E - Household Number - E Press the Program button (P). Press the Program Number (16). Enter the Building (Management) PIN. Press the Call button (E). Press the Call button (E). Household Number. ex) 101 ex)1 2 3 4 for household 101 Press the Call button (E). ① Press the Program button.‘Prog’ will appear) ② Enter the Building (Management) PIN. ③ Press the Call button (E). ④ Press the Program Number (16). ⑤ Press the Call button (E).‘hono’ will blink) ⑥ Enter the Household Number. (The Household Number will be indicated) ⑦ Press the Call button (E). (The Household PIN will be indicated) - 14 - DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지15 7.Configuring Building and Serial Numbers in the Main Entrance Interphone This feature must be performed for it automatically configures Building and Serial numbers when Households or the Guardhouse is paged from the Main Entrance. Up to 99 Main Entrance interphones can be installed per each building. 7-1. Configuring Building Number from the Main Entrance Interphone P - Building (Management) PIN - E - 2 - E - Building Number - E Press the Program button (P). Press the Program Number (2). Enter the Building (Management) PIN. Press the Call button (E). The Building Number previously entered will be indicated ex) 1234 Building Press the Call button (E). Enter the New Building Number Building Number has been updated. Press the Call button (E). ① Press the Program button (P).‘Prog’ will appear) ② Enter the Building (Management) PIN. ③ Press the Call button (E). ④ Press the Program Number (2). ⑤ Press the Call button (E). (The Building Number previously entered will be indicated) ⑥ Enter the new Building Number. ⑦ Press the Call button. Building Number has been updated. - 15 - DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지16 7-2. Configuring Serial Number from the Main Entrance Interphone P - Building (Management) PIN - E - 3 - E - Serial Number - E Press the Program button (P). Press the Program Number (3). Enter the Building (Management) PIN. Press the Call button (E). The Serial Number previously entered will be indicated Press the Call button (E). Enter the New Serial Number ex) No. 2 Serial Number has been updated. Press the Call button (E). ① Press the Program button (P).‘Prog’ will appear) ② Enter the Building (Management) PIN. ③ Press the Call button (E). ④ Press the Program Number (3) . ⑤ Press the Call button (E). (The Serial Number previously entered will be indicated) ⑥ Enter the new Serial Number. ⑦ Press the Call button Serial Number has been updated. - 16 - DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지17 8. Using Remote Cardkeys (RF/ID) - Optional 8-1. Testing Remote Cardkeys P - Building (Management) PIN - E - 9 - E - Card Test - X (Cancel) This feature is used to test Remote Cardkeys. Press the Program button (P). Enter the Building (Management) PIN. Press the Call button (E). Press the Card Here Press the Program Number (9). Press the Call button (E). ex) Card Number 3579 Place the Remote Cardkey to the RF/ID Receptor, and the Card Number will appear on the Display Window (FND). Press the Cancel button (X) to end Remote Cardkey testing To confirm others cardkey, place continuedly the Remote Cardkey to the RF/ID Recepter ① Press the Program button (P).‘Prog’ will appear) ② Enter the Building (Management) PIN. ③ Press the Call button (E). ④ Press number 9 (Remote Cardkey Test). ⑤ Press the Call button.‘Cdtt’ will blink) ⑥ Place the Remote Cardkey to the RF/ID Receptor, and the Card Number will appear on the Display Window (FND). ⑦ Press the Cancel button (X) to end Remote Cardkey testing. - 17 - DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지18 8-2. Remote Cardkey Registration P - Building (Management) PIN - E - 10 - E - Card Registration - X (Cancel) Press the Program button (P). Enter the Building (Management) PIN. ex) Building PIN Press the Call button (E). Press the Card Here Press the Program Number (10). Press the Call button (E). Place the Remote Cardkey to the RF/ID Receptor, and ‘Cdsv’ or ‘CdAL’ will appear Newly Registered Card Press the Cancel button (X) to end Remote Cardkey testing Previously Registered Card To confirm others cardkey, place continuedly the Remote Cardkey to the RF/ID Recepter CdSv: Newly Registered Card (Successful registration is indicated by a beep) CdAl: Previously Registered Card (Rejected registration is indicated by two beeps) Up to 2048 Remote Cardkeys can be registered. (Without a computer connected) Please record registered Remote Cardkey’s serial number for future reference. - 18 - DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지19 8-3. Individual Deletion of Remote Cardkeys P - Building (Management) PIN - E - 12 - E - Card Deletion - X (Cancel) Press the Program button (P). Enter the Building (Management) PIN. ex) Building PIN Press the Call button (E). Press the Card Here Press the Program Number (12). 1. Place the Card on top of the RF/ID Receiver, and will delete Card Number Press the Call button (E). 2. Enter Card Number and press Call button, and will delete Card Number ex) Card Number 19919 ex) For Card Number 19919 delete Press the Cancel button (X) to terminate the feature ① Press the Program button (P).‘Prog’ will appear) ② Enter the Building (Management) PIN. ③ Press the Call button (E). ④ Press number 12 (Individual Remote Cardkey Deletion). ⑤ Press the Call button (E).‘CddE’ will blink) ⑥ Enter the 5-digit Card Number and press the Call button (E). (Check on the right side of the RF/ID Card) Or place the Card on top of the RF/ID Receiver. ⑦ Press the Cancel button (X) to terminate the feature - 19 - DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지20 8-4. Confirming Remote Cardkey Registration P - Building (Management) PIN - E - 13 - E - Card Confirmation - X (Cancel) Press the Program button (P). Press the Program Number (13). Enter the Building (Management) PIN. ex) Building PIN Press the Call button (E). Press the Card Here 1. Place the Card on top of the RF/ID Receiver, and will confirm. Confirm Card 2. Enter Card Number and press Call button, and will confirm Remote Cardkey Registration. ex) Card Number 19919 Press the Call button (E). No Confirm Card ex) For Card Number 19919 Confirm Press the Cancel button (X) to terminate the feature ① Press the Program button (P).‘Prog’ will appear) ② Enter the Building (Management) PIN. ③ Press the Call button (E). ④ Enter number 13 (Remote Cardkey Confirmation). ⑤ Press the Call button (E).‘CddE’ will blink) ⑥ Enter the 5-digit Card Number and press the Call button (E). (Check the right side of the RF/ID Card) Or place the Card on top of the RF/ID Receiver. ⑥ Press the Cancel button (X) to terminate the feature. - 20 - DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지21 8-5. All Remote Cardkey deletion P - Building (Management) PIN - E - 11 - E - E Refrain from deleting all Remote Cardkeys, except for during installation. Press the Program button (P). Press the Program Number (11). Press the Call button (E). Enter the Building (Management) PIN. ex) Building PIN Press the Call button (E). All Remote Cardkey mode Press the Call button (E). All Remote Cardkey mode ① Press the Program button (P).‘Prog’ will appear) ② Enter the Building (Management) PIN. ③ Press the Call button (E). ④ Enter number 11 (All Remote Cardkey Delete Number). ⑤ Press the Call button (E).‘dEL’ will blink) ⑥ Press the Call button (E) again. The number displayed on screen will change. ⑦ Press the Cancel button (X) to terminate the feature. - 21 - DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지22 8-6. Remote Cardkey Capacity Expansion P - Building (Management) PIN - E - 19 - E - 0 - E: Maximum 2048 Cards can be registered. P - Building (Management) PIN - E - 10 - E - 1 - E: Unlimited number of Cards can be registered. (This feature is only available when connected to a computer) Press the Program button (P). Enter the Building (Management) PIN. ex) Building PIN Press the Call button (E). The current capacity is displayed. Press the Call button (E). Press the Program Number (19). Select the Card capacity. Maximum 2048 Press the Call button (E). ex) Unlimited Unlimited ① Press the Program button (P).‘Prog’ will appear) ② Enter the Building (Management) PIN. ③ Press the Call button (E). ④ Enter number 19 (Remote Cardkey Capacity Change). ⑤ Press the Call button (E). (The current capacity is displayed) ⑥ Select the Card capacity. (0: Maximum 2048) (1: Unlimited) ⑦ Press the Call button (E). (Updated) - 22 - Updated DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지23 9. Surveillance Monitor Configuration P - Building (Management) PIN - E - 4 - E - 0 - E: Surveillance disabled. P - Building (Management) PIN - E - 4 - E - 1 - E: Surveillance enabled. This feature provides entrance surveillance of the Main Entrance to a separate monitor by using the Camera from the Main Entrance Interphone. Press the Program button (P). Enter the Building (Management) PIN. ex) Building PIN Press the Call button (E). Previous selection is displayed Press the Program Number (4). Press the Call button (E). Choose a mode Surveillance monitor cannot be installed ex) Surveillance Configurated Surveillance monitor can be installed ① Press the Program button (P).‘Prog’ will appear) ② Enter the Building (Management) PIN. ③ Press the Call button (E). ④ Press number 4 (Surveillance Monitor Configuration). ⑤ Press the Call button (E). (Previous selection is displayed) ⑥ Choose a mode. (0: Surveillance monitor cannot be installed) (1: Surveillance monitor can be installed) ⑦ Press the Call button (E). (Modification updated) - 23 - Press the Call button (E). Modification updated DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지24 10. Door Release Time Setup P - Building (Management) PIN - E - 5 - E - Door Release Time - E This feature adjusts the door release time. Press the Program button (P). Enter the Building (Management) PIN. ex) Building PIN Press the Call button (E). The current capacity is displayed. Press the Call button (E). Press the Program Number (5). Choose a time. Use numbers from 1 to 25. Press the Call button (E). ex) Door Release time Selected 10 seconds Modification updated ① Press the Program button (P).‘Prog’ will appear) ② Enter the Building (Management) PIN. ③ Press the Call button (E). ④ Press number 5 (Door Release Time Setup). ⑤ Press the Call button (E). (Previous selection is displayed) ⑥ Choose a time. (From 1 to 25 seconds) Use numbers from 1 to 25. ⑦ Press the Call button (E). (Modification updated) - 24 - DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지25 11. Page Tone Selection P - Building (Management) PIN - E - 7 - E - 0 - E: Melody Tone P - Building (Management) PIN - E - 7 - E - 1 - E: Bell (Ringer) This feature sets the Recall tone heard when Households or the Guardhouse is paged from the Main Entrance. Press the Program button (P). Enter the Building (Management) PIN. ex) Building PIN Press the Call button (E). The current capacity is displayed. Press the Call button (E). Press the Program Number (7). Selection a Page Signal 0: Melody Tone 1: BELL Tone(RINGER) Press the Call button (E). ex) Selection a Page Signal selected melody tone Page signal updated ① Press the Program button (P).‘Prog’ will appear) ② Enter the Building (Management) PIN. ③ Press the Call button (E). ④ Press number 7 (Page Signal Selection). ⑤ Press the Call button (E). (Previous selection is displayed) ⑥ Select a page signal. 0: Melody Tone 1: Bell (Ringer) ⑦ Press the Call button (E). (Page signal updated) - 25 - DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지26 12. Wiring Method Selection P - Building (Management) PIN - E - 6 - E - 4 - E: 4-wire Common Method (12-wire common) P - Building (Management) PIN - E - 6 - E - 8 - E: 8-wire Common Method Video images from the Main Entrance cannot be viewed in the Household when the 8-wire Common Method has been selected. Press the Program button (P). Enter the Building (Management) PIN. ex) Building PIN Press the Call button (E). The current capacity is displayed. Press the Call button (E). Press the Program Number (6). Select a wiring method 4: 4-wire Common Method (12-wire common) 8: 8-wire Common Method Press the Call button (E). ex) Wiring method selected 4- wire commom method Wiring method updated ① Press the Program button (P).‘Prog’ will appear) ② Enter the Building (Management) PIN. ③ Press the Call button (E). ④ Press number 6 (Wiring Method Selection). ⑤ Press the Call button (E). (Previous selection is displayed) ⑥ Select a wiring method. 4: 4-wire Common Method (12-wire common) 8: 8-wire Common Method ⑦ Press the Call button (E). (Wiring method updated) - 26 - DRC-481L/DRC-500L-영문 2006.10.26 1:23 PM 페이지27 13. Video Out Impedance Adjustment P - Building (Management) PIN - E - 8 - E - 0 - E: Short Distance P - Building (Management) PIN - E - 8 - E - 1 - E: Long Distance By default, the unit is set for short distance. Do not change if possible. Press the Program button (P). Enter the Building (Management) PIN. ex) Building PIN Press the Call button (E). The current capacity is displayed. Press the Program Number (8). Press the Call button (E). Select the Impedance 0: Short Distance 1: Long Distance Press the Call button (E). ex) Impedance Adjusted short distance Impedance selection updated ① Press the Program button (P).‘Prog’ will appear) ② Enter the Building (Management) PIN. ③ Press the Call button (E). ④ Press number 8 (Impedance Setup). ⑤ Press the Call button. (The previous selection is displayed) ⑥ Select the impedance. 0 : Short Distance 1 : Long Distance ⑦ Press the Call button (E). (Impedance selection updated) - 27 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지28 14. Household Interphone Diagnosis P - Building (Management) PIN - E - 14 - E - Household Number - E This feature checks for the Household Interphone’s operating conditions. Press the Program button (P). Enter the Building (Management) PIN. ex) Building PIN Press the Call button (E). Check feature the Household Videophone Press the Program Number (14). Press the Call button (E). Enter the Household Number, then press the Program button. ex) check for 101 Enter the Multi Sub Number, then press the Page button (E). ex) check for master status The Household’s status is shown on the display window (FND). Normal status Busy status Away status Press the Call button (E). Emergency status After checking the currently displayed household, it will show automatically a next household. Push the call button to check a next household. You can check the whole households in the same way. After checkup, push the cancel button. - 28 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지29 ① Press the Program button (P).‘Prog’ will appear) ② Enter the Building (Management) PIN. ③ Press the Page button (E). ④ Enter number 14 (Household Interphone Diagnosis). ⑤ Press the Page button (E).‘Subt’ will appear) ⑥ Enter the Household Number, then press the Program button. ⑦ Enter the Multi Sub Number, then press the Page button (E). The Household’ s status is shown on the display window (FND). (Please refer to the following indications) ⑧ To check other Households, repeat steps 6 and 7. Press the Cancel button (X) to terminate the feature. Household Status Normal Status - The Household is in standby. (Normal will also be indicated if the Household is in conversation with the Entrance or on the phone) Busy Status - The Household is on the phone. (Busy status is only shown when in conversation with the Guardhouse) Away Status - Residents are currently away from their Household. Emergency Status - There is an emergency situation in the Household. (Emergency, Warning 1 (Fire), Warning 2 (Gas), Burglary, and etc are indicated as emergency situations) Error Status - Connection could not be established with the Household. (Please check the Household Videophone) - 29 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지30 15. Household Number Registration P - Building (Management) PIN - E - 15 - E - Guardhouse page from the Household Household Number - P - Serial Numbe - E This feature is used to register Household Numbers through the Main Entrance Interphone when the Guardhouse Interphone has not been installed. If the Guardhouse Interphone is available, please use it to register. Press the Program button (P). Enter the Building (Management) PIN. ex) Building PIN Press the Call button (E). Household PIN Entry Mode Press the Program Number (15). Press the Call button (E). Lift up the receiver from the Household and press the Guard button to page the Main Entrance Interphone, where the Household Number will be displayed. (Then, the displayed number must be changed for it is the default number from the factory.) ex) Entering as first 1234 Enter the Household number and press the Program button. ex) Entering as Unit 101 Enter the Multi Sub number and press the Page button (E). ex) Entering as Master Press the Call button (E). Follow the same procedure to enter other Households. Press the Cancel button (X) to end. - 30 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지31 What is Multi Sub Number? Refers to individual numbers for each videophone in the Household when there is more than one. The Master’s Serial Number is 0. Sub Serial Numbers are from 1 to 9. Maximum 10 videophones can be installed in a household, and their serial numbers must not overlap. A Master must exist among numerous videophones. If only one videophone exists, that unit shall be registered as the Master. When ADT-481 is installed in the Household, that unit will not be registered as the Master. ① Press the Program button (P).‘Prog’ will appear) ② Enter the Building (Management) PIN. ③ Press the Page button (E). ④ Enter number 15 (Household Number Registration). ⑤ Press the Page button (E).‘SUbA’ will appear) ⑥ Lift up the receiver from the Household and press the Guard button to page the Main Entrance Interphone, where the Household Number will be displayed. Then, the displayed number must be changed for it is the default number from the factory. ⑦ Enter the Household number and press the Program button. ⑧ Enter the Multi Sub number and press the Page button (E). ⑨ The Main Entrance Interphone’ s Display Window will convert to the (5) status. ⑩ To enter different Households, repeat steps 6 and 7. ⑪ Press the Cancel button (X) to end. - 31 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지32 16. Paging the Household Enter theHousehold Number. Press the page button. A paging tone will sound. ex) unit 101 Press the Call button (E). Wait for a reply 17. Paging the Guardhouse Press the Guard button. Press the Page button. A paging tone will sound. Press the Call button (E). Wait for a reply - 32 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지33 18. Door Release Using the Household PIN Household Number - K - Household PIN - E Press the Electronic key button. Enter the Household Number. ex) To open the door of unit 101 Enter the Household PIN. Press the Page button. Press the Call button (E). 19. Door Release Using the Building (Management) PIN G - K - Building (Management) PIN - E Press the Guard button. Press the Electronic key button. Enter the Building or the Management PIN. Press the Page button. Press the Call button (E). - 33 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지34 20. Appendix (Various Program Summaries) Various PIN Programs 1. P - Old Management PIN - E - 0 - E - New PIN- E: Management PIN Change 2. P- Old Building PIN - E -1 - E - New PIN - E: Building PIN Change 3. K - 20 - E - Household Number - E - Old Household PIN - E - New PIN - P: Household PIN Change 4. P - Building (Management) PIN - E - 16 - E - Household Number - E: Household PIN Confirmation Configuring Building and Serial Numbers from the Main Entrance Interphone 1. P - Building (Management) PIN - E - 2 - E - Building Number - E: Building Number Setup 2. P - Building (Management) PIN - E - 3 - E - Serial Number - E: Serial Number Setup Remote Cardkey Programs 1. P - Building (Management) PIN - E - 9 - E: Remote Cardkey Test 2. P - Building (Management) PIN - E - 10 - E: Remote Cardkey Registration 3. P - Building (Management) PIN - E - 11 - E: All Remote Cardkey Delete (Household PIN Delete) 4. P - Building (Management) PIN - E - 12 - E: Individual Cardkey Delete 5. P - Building (Management) PIN - E - 13 - E: Remote Cardkey Confirmation 6. P - Building (Management) PIN - E - 19 - E: Expanding Remote Cardkey Capacity Door Release Using Various PINs 1.GP - KP - Building (Management) PINP - E: Door release using Building (Management) PIN 2.Household NumberP - KP - Household PINP - E: Door release using Household PIN Other Feature Setup Methods 1.P - Building (Management) PIN - E - 4 - E: Surveillance Monitor Setup 2.P - Building (Management) PIN - E - 5 - E: Door Release Time Setup 3.P - Building (Management) PIN - E - 6 - E: Wiring Method Selection 4.P - Building (Management) PIN - E - 7 - E: Paging Tone Selection 5.P - Building (Management) PIN - E - 8 - E: Video Out Impedance Selection 6.P - Building (Management) PIN - E - 14 - E: Household Interphone Diagnosis 7.P - Building (Management) PIN - E - 15 - E: Household Number Registration 8. P - Building (Management) PIN - E - 17 - - 34 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지35 21. Wiring Method 1) Guardhouse Interphone (CDS-481L) Bk Br R Or Y G B Pu G For Internal Phone Line Bk Br R Or Y G B Pu G GND DATA Talk 3 Talk 2 Talk 1 Bk: Black Br: Brown R: Red Or: Orange Y: Yellow G: Green B: Blue Pu: Purple G: Gray For Computer Connection (Optional) Connection to a Computer Rear Code Terminal Talk 1~8, Data Terminal for connection with external Phone lines. Rear Code Terminal 1-2 3-4 5-6 7-8 9-10 11-12 13-14 15-16 17 18 Call 1 Call 2 Call 3 Call 4 Call 5 Call 6 Call 7 Call 8 Data GND (TIV 0.65mm×2C Non Polar) (TIV 0.65mm×2C Non Polar) (TIV 0.65mm×2C Non Polar) (TIV 0.65mm×2C Non Polar) (TIV 0.65mm×2C Non Polar) (TIV 0.65mm×2C Non Polar) (TIV 0.65mm×2C Non Polar) (TIV 0.65mm×2C Non Polar) (TIV 0.65mm Polar) (TIV 0.65mm Polar) 1-2 3-4 5-6 7-8 9-10 11-12 13-14 15-16 Call 1 Call 2 Call 3 Call 4 Call 5 Call 6 Call 7 Call 8 (TIV 0.65mm×2C Non Polar) (TIV 0.65mm×2C Non Polar) (TIV 0.65mm×2C Non Polar) (TIV 0.65mm×2C Non Polar) (TIV 0.65mm×2C Non Polar) (TIV 0.65mm×2C Non Polar) (TIV 0.65mm×2C Non Polar) (TIV 0.65mm×2C Non Polar) Talk 9~16, Data - 35 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지36 2) Main Entrance Interphone (DRC-481L) Bk Br Or Bk: Black Br: Brown R: Red Or: Orange Y: Yellow G: Green B: Blue Pu: Purple G: Gray W: White Bk Br Or Infrared Sensor Bk Br Or Pu Guardhouse (Household Videophone) Bk Br Or (Household Videophone) Bk Br Or Monitor Security Door Release Mechanism Security ① DC 12V used. ② Designed to be used by connecting to the lead switch. When not in use, please connect two wires. ③ When the Main Entrance is opened by force, the Guardhouse and the computer are notified. - 36 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지37 (DRC-500L) Bk Br Or Bk: Black Br: Brown R: Red Or: Orange Y: Yellow G: Green B: Blue Pu: Purple G: Gray W: White Bk Br Or Bk Br Or Pu Guardhouse (Household Videophone) Bk Br Or (Household Videophone) Bk Br Or Monitor Infrared Sensor Door Release Terminal Security ① Use DC 15V. ② It is designed to use a reed switch. When it is not used, connect two lines. ③ When the main entrance door is forced to open, it will be notified to the guardhouse and a computer. - 37 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지38 3) Household Videophone(CH-481SL) Telephone Bk Br Or Bk Br Or Pu Bk Br Or Pu Bk Br Or 4) Household Videophone(APV-481FT) Bk Br Or Pu - 38 - Talk Main Entrance Talk 1 Talk 2 Guardhouse Talk 3 Warring1 Sensor Warring2 Emergency Main Entrance Call Household Camera Talk Main Entrance Talk 1 Talk 2 Sensor Burglar Telephone Bk Br Or Household Camera Guardhouse Talk 3 Emergency Bk Br Or Main Entrance Call Extention Extention Bk: Black Br: Brown R: Red Or: Orange Y: Yellow G: Green B: Blue Pu: Purple G: Gray W: White DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지39 5) Household Videophone(CAV-50FSD) Telephone Bk Br Or Bk Br Or Pu Bk Br Or Pu Bk Br Or Household Camera Talk Main Entrance Talk 1 Talk 2 Guardhouse Talk 3 Warring1 Sensor Warring2 Sensor Burglar Emergency Main Entrance Call Extention 6) Household Videophone(CAV-50FD) Telephone Bk Br Or Bk Br Or Pu Bk Br Or - 39 - Household Camera Talk Main Entrance Talk 1 Talk 2 Guardhouse Talk 3 Main Entrance Call Extention Bk: Black Br: Brown R: Red Or: Orange Y: Yellow G: Green B: Blue Pu: Purple G: Gray W: White DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지40 7) Household Videophone(CAV-501D) Telephone Bk Br Or Bk Br Or Pu Bk Br Or Pu Bk: Black Br: Brown R: Red Or: Orange Y: Yellow G: Green B: Blue Pu: Purple G: Gray W: White Bk Br Or - 40 - Household Camera Talk Main Entrance Talk 1 Talk 2 Guardhouse Talk 3 Warring1 Sensor Warring2 Burglar Emergency Main Entrance Call Extention DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지41 8) Household Videophone(CAV-482S) Bk Br Or Bk Br Or Pu Bk Br Or Pu Bk Br Or Bk Br Bk: Black Br: Brown R: Red Or: Orange Y: Yellow G: Green B: Blue Pu: Purple G: Gray W: White Bk Br Or - 41 - Telephone Household Camera Talk Talk 1 Talk 2 Talk 3 Main Entrance Guardhouse Warring1 Sensor Warring2 Burglar Sensor Emergency Burglar 1 Sensor Sensor Burglar 2 Communication Power Main Entrance Call Extention DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지42 9) TV-Phone Interface Adaptor(ADT-481) Unit DC Talk 1 Talk 2 Guardhouse Talk 3 Extention Main Entrance Call Guardhouse(CKV-60T) Door Release(CKV-60T) Camera Bk Br Or Pu Bk: Black Br: Brown R: Red Or: Orange Y: Yellow G: Green B: Blue Pu: Purple G: Gray W: White Bk Br Or Bk Br Or Pu 10) Security Interface Adaptor(ADT-482) Power (Supply of CAV-482S) Burglar 1 Sensor Sensor Burglar 2 Sensor Burglar 1 Burglar 2 Sensor Communication Telephone Bk Br Or Bk Br Or Bk Br - 42 - - 43 - Lobby Phone Common 4 Czmera Monitor Household Videophone Lobby 1 Guardhouse Lobby 2 Lobby Phone Household Videophone Monitor : Guardhouse Line (Common 8-wire) : Main Entrance Line (Common 4-wire) : External Call Line (Common 18-wire) : Enternal Extension Line (Common 16-wire) → Optional ※ Note Lobby Phone Common 4 Czmera Lobby 1 Guardhouse Lobby 2 Lobby Phone DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지43 11) System Map DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지44 12) Wiring Method for Communications with the Guardhouse Bk: Black Br: Brown R: Red Or: Orange Y: Yellow G: Green B: Blue Pu: Purple G: Gray W: White Bk Br Or Pu Bk Br Or Pu Bk Br Or Pu Bk Br Or Pu Bk Br Or Pu Bk Br R Or Y G B Pu - 44 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지45 13) Main Entrance Interphone Wiring ※ NOTE 1. Main Entrance System Bk CALL Br GND Or VD/IN VD/OUT 2. Household Videophone Bk CALL Br GND Or VD/IN VD/OUT Bk Br Or Bk Br Or Bk Br Or Bk Br Or Bk Br Or Camera 1 Bk: Black Br: Brown R: Red Or: Orange Y: Yellow G: Green B: Blue Pu: Purple G: Gray W: White Bk Br Or Bk Br Or Camera 2 Bk Br Or 3. If the Guardhouse Interphone (CDS-481L) has been installed, Number 7 (Data) and 8 (GND) connected to it must be connected to the Household Interphone. 4. Use coaxial cables (3C2V or 5C2V) for Video Out. - 45 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지46 14) Wiring ADT-481 and CKV-60T Bk: Black Br: Brown R: Red Or: Orange Y: Yellow G: Green B: Blue Pu: Purple G: Gray W: White Guardhouse Guardhouse OPEN/CLOSE OPEN/CLOSE IN GND B+ VD Bk Br Or Pu 15) Wiring ADT-482 and CAV-482S Telephone Telephone Household Camera Main Entrance Burglar 1 Burglar 2 Guardhouse Sensor Bk Br Or Bk Br Or Sensor Sensor Extention Communication Bk Br Or Bk Br - 46 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지47 16) Installing Numerous Videophones in a Household Multysub Number Multysub Number Multysub Number Bk Br Or Bk Br Or Bk Br Or Multysub Number Household Camera Multysub Number Loby Talk Loby Talk Multysub Number Multysub Number Loby Talk Multysub Number Household Camera Bk Br Or Loby Talk Bk Br Or Loby Talk Bk Br Or Loby Talk ※NOTE 1. : Guardhouse Line (8-wire Common) : Main Entrance Line (4-wire Common) : Sub Extension (6-wire Common) 2. When registering the Multi Sub number, ADT-481 will not be recognized as the Master and should be installed last as shown above. 3. Various types of sensors should be connected to the Master, and sensors of the remaining Subs should be connected with the + wire and the sensor line: if the two lines are not connected, the Away mode will not function. - 47 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지48 17) CCTV and Sensor Wiring CAMERA 1 Monitor 1 R: Red Y: Yellow B: Blue W: White CAMERA 2 Monitor 2 ※ NOTE 1. Monitor 1: To view only when being used by the Main Entrance Interphone (DRC-481L). 2. Monitor 2: Continuous surveillance of the Main Entrance. - 48 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지49 ①Or(Line) ②Or ③G(Line) ④B ⑤B(Line) ⑥G ⑦Br(Line) ⑧Br Bk Br Or Bk Br Or Bk Br Or Bk Br Or 18) Wiring DRC-481L and CDS-481PC - 49 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지50 19) Wiring CDS-481PC and Multi Port - 50 - 22. Specifications Installation Method Specfications Model Transmission System Rated Voltage Power Consumption Flush Mounted DRC-481L Household Videophone (4-wire Common), Guardhouse Interphone (8-wire Common) DC12V 1A(RF-1A) DC15V/1A(CS-15C) Standby: 200mA, Max: 450mA B/W C.C.D 1/3• , COLOR C.C.D. 1/4• Imaging Device 15,735KHz/60Hz, 15,625KHz/50Hz, Scanning Frequency Horizontal: 68• Camera Angle 3C2V Coaxial 5C2V Coaxial 7C2V Coaxial 200m 300m 400m RF ID 60mm Detection Range B/W: Infrared LED× 4, COLOR: Lighting necessary at night -10C• ~40C• Ambient Temperature Dimensions Vertical: 55• 0.1Lux(300mm in front of camera) Minimum Illumination Lighting DC:Standby:400mA, Max:500mA Hands Free (One Way) Communication Method Communication Distance DRC-500L 230(W)× 260(H)× 72(D)mm - 51 - 245(W)× 275(H)× 63(D)mm DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지52 MEMO - 52 - DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지53 DRC-481L/DRC-500L-영문 2006.10.26 1:24 PM 페이지54 a513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int’l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com Printed In Korea
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : ezPDFGate with Acrobat Distiller Create Date : 2006:10:26 04:24:50Z Modify Date : 2007:04:19 11:59:56+09:00 Metadata Date : 2007:04:19 11:59:56+09:00 Creator Tool : #QuarkXPress3.3K: AdobePS 8.7.3 .1. Document ID : uuid:840c028f-610d-4a61-a08d-fcf85d7f201c Instance ID : uuid:fc1fad35-295d-4d20-8848-69acf9f3faaf Format : application/pdf Creator : .... Title : DRC-481L/DRC-500L-.... Has XFA : No Page Count : 57 Author : ....EXIF Metadata provided by EXIF.tools