REMOTE CONTROLLER FUNCTIONS
The usefulness of the Prevent system is enhanced by the versatility of the Remote Controller.
The pool and the surrounding area are always available for supervised use.
The four modes described below allow a high degree of flexibility – while providing maximum
protection – without sacrificing the pleasure and enjoyment of owning a swimming pool.
Try each of the modes. Watch and listen for the indications listed on the right side of each box.
Reminder: Each click must occur within one second of the preceding click in order to register.
Also, there is a one second delay following the last click before the desired action takes place.
WALK THROUGH MODE
Allows the user to break the laser beam
and enter the pool area without sounding
the alarm. Another single Click allows
the user to leave the pool area.
SWIM MODE
Allows the user to break the laser beam
and enter and leave the pool area for a
30 minute period without sounding the
alarm.
FALSE ALARM CANCEL MODE
Allows the user to silence the alarm after
clearing the obstruction from the beam
path. The alarm cannot be silenced If the
obstruction remains in the beam path.
SET-UP MODE
This maintenance mode allows the user
to align the Mirrors and Reflectors.
Alarm will not sound when in the Set-up
Mode. A single Click will reset the
system when adjustments are completed.
24
• Lasers shut OFF
• Green indicator light
on
Transceiver FLASHES
• Alarm CHIRPS every 3
• Lasers shut OFF
• Green indicator light
on
Transceiver FLASHES
• Alarm CHIRPS every 30
seconds
• System RESETS in 30
• CANCELS a false alarm
• Immediately returns
the system
to FUN TIONAL Mode
• Lasers are ON
• Alarm is SILENCED
• Green indicator light
on
Transceiver FLASHES
• Alarm CHIRPS every 2
CHANGING THE REMOTE CONTROLLER CHANNEL, AND REPLACING THE BATTERY
The Remote Controller provided with the Prevent system is capable of operating on four different
channels. The factory setting is Channel 1. Occasionally, due to interference from other nearby
radio frequency devices, it is necessary to change to a different channel. Proceed as shown
below.
ON
• Enter the Set-Up Mode by
clicking the Remote 4 CLICKS.
• Remove the cover from the
Transceiver.
• Open the Remote Controller by
removing the four screws from
the bottom.
• Set switches #1 & #2 in the
Remote Controller, and switches
#5 & #6 in the Transceiver to
match one of the Channel
combinations shown at the right.
• Do not change any other switch
settings.
• Replace the covers.
• Click the Remote 1 CLICK to
reset the system.
Battery: 3 Volt,
Lithium
2032
Channel
4 5 6 7
Channel
ON
4 5 6 7
ON
4 5 6 7
Channel
ON
Channel
(Factor
4 5 6 7
The life of the battery in the Remote Controller will vary with
the amount of use of the unit. It is recommended that the
battery be replaced once each year.
INDICATOR LIGHTS
Transceiver:
Green Solid Light = Functional and Active
Green Blinking = In Set-up or Swim Mode
Red Light Off = Batteries are charged and functional
Red Light Blinking = Batteries are low, check batteries.
Refer to Page 14 for battery replacement instructions
Remote Controller:
Red Light Blinks when button pushed = Normal function
No Red Light when button pushed = Batteries need to be replaced
Jeff Additions:
Trouble Shooting Guide?
Replacement Parts List
25
PREVENT
Limited Warranty
The Prevent Area protection system is warranted against defects in material and
workmanship, excluding batteries, for a period of one year from the date of purchase.
The Prevent system which fails or become defective during the warranty period,
except as a result of improper installation and/or maintenance, improper operation,
improper environment, improper re-packaging or damage incurred in shipping, fire,
wreckage, freezing, willful abuse, shall be repaired or replaced at our option without
charge within ten (10) days of the receipt of defective product, barring unforeseen
delays. This warranty does not extend to consequential damages or other
circumstances including normal discoloration. CSI does not cover labor and shipping
charges which may be necessary to replace the product covered by this warranty.
This warranty extends to the consumer who made the original retail purchase only,
and is not enforceable by any other party.
To obtain warranty replacements or repair, the defective portion of the system should
be returned, transportation paid, to:
CSI
15440 North 77th Street
Scottsdale, Arizona 85260
Should you have specific questions regarding the warranty or return contact us toll
free at 1-800-762-0647. CSI shall not be responsible for cartage, removal and/ or
reinstallation labor, or any other such costs incurred in obtaining warranty
replacements.
Some states do not allow a limitation on how long an implied warranty lasts, or the
exclusion or limitation of incidental or consequential damages, so the above limitation
or exclusion may not apply to you .
This warranty gives you specific legal rights, and you may also have other rights
which vary from state to state.
CSI...(logo)
15540 North 77th Street Scottsdale, Arizona 85260
1-800-762-0647
Fax (602) 951-4319

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2001:07:03 11:16:51
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2001:07:03 11:16:53+01:00
Page Count                      : 3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OFG3-204-35

Navigation menu