WARNING WARNING CLUTCH ADJUSTMENT CAUTION (BELT DRIVE MODEL OPERATORS) Remove the cotter pin from the clutch nut on the clutch shaft. Turn the clutch nut to release tension. Re-tighten the clutch nut until there is just enough tension to permit smooth operation of the door and to allow the clutch to slip if the door is obstructed. WARNING To avoid SERIOUS personal INJURY or DEATH from electrocution: • Disconnect electric power BEFORE performing ANY adjustments or maintenance. Secure the clutch nut with the cotter pin. AVERTISSEMENT AVERTISSEMENT ADJUST TORQUE LIMITER CLUTCH (MODEL GT) ATTENTION AVERTISSEMENT set screws of torque adjustment nut on the gear 1 Loosen reducer. off torque nut until there is very little tension on the 2 Back belleville washers. torque nut gradually until there is just enough tension 3 Tighten to permit the operator to move the door smoothly through a Torque Nut Set Screws complete open/close cycle, but to allow the reducer to slip if the door is obstructed. the set screw that is directly over the flat portion 4 Re-tighten of the shaft. MODEL GH (OPTIONAL MODIFICATION) 1 Loosen set screws on clutch nut. Back off clutch nut until there is very little tension on the 2 ADVERTENCIA clutch spring. clutch nut gradually until there is just enough tension 3 Tighten to permit the operator to move the door smoothly but to allow (3) Set Screws ADVERTENCIA ADVERTENCIA the clutch to slip if the door is obstructed. When the clutch is PRECAUCIÓN properly adjusted, it should generally be possible to stop the door by hand during travel. LOSE OPEN RPM Sensor Logic Board Adjustment ADJUSTMENT AUXILIARY REVERSAL SYSTEM / RPM SENSOR The Auxiliary Reversal System is designed to protect the door and motorized operator. It is NOT a substitute for an entrapment sensing device. Feature: This feature utilizes the RPM sensor connected to the logic board to detect when the clutch slips and reverses the door (clutch must be properly adjusted). In addition, the RPM eliminates the need for a centrifugal switch on single phase motors. Benefit: The Auxiliary Reversal System reverses the operator upon hitting an obstruction, preventing excessive door and operator damage. UL325 requires the use of monitored entrapment protection devices for primary entrapment protection. By removing the centrifugal switch on single phase motors, the leading cause of motor failures is eliminated. (Auxiliary Reversal System is not applicable on GH models unless the clutch modification is installed.) NOTE: This feature is automatically learned and does not require programming. 23 WARNING TESTING WARNING Apply power to the operator. When power is applied to the operator, the following LED’s will illuminate: STOP, CLOSE, OPEN, LMEP, 24Vac, RADIO, DATA, TIMER ENABLE, OLS MID, SLS, CLS, and MAS. Once the power up process is completed (approximately 2-3 seconds) only the appropriate LED’s will continue to be lit: • Between limits: 24Vac and STOP • Fully closed position: 24Vac, STOP, CLS and SLS • Fully opened position: 24Vac, STOP and OLS Additional LED’s will light when device(s) are activated. NOTE: When the power up process is over, the MAS LED will blink a code indicating the version of firmware. If the selector dial is in the DIAG, OPTN, or PROG position, the MAS will not provide this code. After the code has been provided the MAS LED will go out. CAUTION WARNING To avoid SERIOUS personal INJURY or DEATH: • Disconnect electric power BEFORE performing ANY adjustments or maintenance. • ALL maintenance MUST be performed by a trained door systems technician. TEST 3-BUTTON CONTROL STATION 1. Press OPEN button. (The door should move in the open direction.) 2. Press STOP button. (The door should stop.) 3. Press and hold the CLOSE button. (The door should move in the close direction.) 4. Release CLOSE button. Door should stop if in C2 or D1 mode. Door will reverse to full open position in E2 mode. The door should continue closing in all other modes. 5. Press STOP button. (The door should stop.) AVERTISSEMENT AVERTISSEMENT ATTENTION AVERTISSEMENT TEST PHOTOELECTRIC SENSORS (IF APPLICABLE) 1. Open the door. 2. Place an obstruction in the path of the photoelectric sensors. The LMEP LED will blink on the logic board. 3. Press and hold the CLOSE button. The door should not close. 4. Remove the obstruction. 5. Press and hold the CLOSE button. Door should close. If the LMEP is activated while closing the door should reverse. TEST LIMIT ADJUSTMENT 1. Press OPEN button. (The door should open.) 2. Allow the door to fully open. 3. Press and hold the CLOSE button. (The door should close.) 4. Allow the door to fully close. 5. If the limits are not set properly, remove power and adjust limits (refer to Limit Adjustment section). TEST EDGE SENSORS (IF APPLICABLE) 1. Open door. 2. Place an obstruction in the path of the door. 3. Press and hold the CLOSE button. The door should stop and/or reverse. 4. Remove obstruction and hold the CLOSE button. Door should fully close. NOTE: The Logic 5 control board will automatically learn the LMEP device once it is properly connected. If the LMEP device is misaligned, activated, or disconnected the LMEP LED on the logic control board will blink on and off. You can close the door by entering the Restricted Close (RC) mode by holding the close button. The operator will begin closing after 5 seconds and will continue to close to the Close Limit or when the close button is released. To unlearn the LMEP device, turn the selector dial to DIAG, push and hold the stop button until the MAS LED flashes. Without the LMEP device connected the only mode of operation will be B2, D1 or E2. IMPORTANT NOTES: • Be sure you have read and understand all safety instructions included in this manual. • Be sure the owner or person(s) responsible for operation of the door have read and understand the safety instructions, know how to electrically operate the door in a safe manner and how to manually disconnect the door from the operator. ADVERTENCIA ADVERTENCIA ADVERTENCIA TESTING PRECAUCIÓN Testing 24 MANUAL RELEASE EMERGENCY DISCONNECT SYSTEM MODEL GT AND T WARNING To prevent possible SERIOUS INJURY or DEATH from a falling door or arm: • DO NOT stand under the door arm when pulling the emergency release. • If possible, use emergency release handle to disengage trolley ONLY when door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly. • NEVER use emergency release handle unless doorway is clear of persons and obstructions. TO DISCONNECT DOOR FROM OPERATOR The door should be in the fully closed position if possible. Pull emergency release handle straight down. Emergency disconnect will open. CAUTION TO RECONNECT DOOR ARM TO TROLLEY Lift free end of door arm to trolley. Pull emergency release handle to allow arm to engage roll pin. Release handle. Emergency disconnect will close. AVERTISSEMENT ATTENTION NOT ICE EMERGENCY DISCONNECT SYSTEM MODEL APT ADVERTENCIA MANUAL RELEASE TO DISCONNECT DOOR FROM OPERATOR The door should be in the fully closed position if possible. Pull down on the emergency release handle and raise or lower the door manually. PRECAUCIÓN TO RECONNECT DOOR ARM TO TROLLEY The trolley will reconnect on the next UP or DOWN operation, either manually or by using the door control or remote. NOT ICE 25 Manual Release WARNING EMERGENCY DISCONNECT SYSTEM MODEL H, GH, J, AND HJ CAUTION To prevent possible SERIOUS INJURY from a moving chain: • DISCONNECT electric power to the operator BEFORE manually operating your door. • If possible, use emergency disconnect ONLY when door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly. • NEVER use emergency disconnect unless doorway is clear of persons and obstructions. This operator has provisions for manually operating the door in case of emergency or power failure. Refer to the appropriate instructions below for your model operator. MODEL H AND GH These operators are equipped with a manual hoist. An electrical interlock will disable the electrical controls when the hoist is used. To operate the hoist: H and GH AVERTISSEMENT Pull the disconnect chain (sash chain) to engage the hoist mechanism. The disconnect chain may be locked in position by slipping the end through the keyhole of the chain keeper mounted on the wall. Operate the door in the desired direction by pulling on one side or the other of the continuous loop hoist chain. The disconnect chain must be released from the chain keeper before the door will operate again electrically. ATTENTION MODEL J This operator has a floor level disconnect chain to disconnect the door from the door operator. To disengage, pull the disconnect chain (sash chain) and secure in the disengaged position by slipping the end through the keyhole bracket mounted on the wall. The door may now be pushed up or pulled down manually. ADVERTENCIA Release the disconnect chain to operate the door again electrically. PRECAUCIÓN MANUAL RELEASE MODEL HJ This operator includes both a floor level disconnect chain (sash chain) to disconnect the door from the door operator and a disconnect chain with manual hoist to electrically disable the operator controls. Pull the disconnect chain to engage the hoist mechanism. The disconnect chain may be locked in position by slipping the end through the keyhole of the chain keeper mounted on the wall. To disengage, pull the disconnect chain and secure in the disengaged position by slipping the end through the keyhole bracket mounted on the wall. Operate the door in the desired direction by pulling on one side or the other of the continuous loop hoist chain. Release the disconnect chain to operate the door again electrically. HJ Manual Release 26 PROGRAMMING INTRODUCTION TO PROGRAMMING Many programmable functions require that a LiftMaster Entrapment Protection (LMEP) device be installed in order to function. Refer to the Entrapment Protection section. LOGIC BOARD PUSH BUTTONS (OPEN, CLOSE, STOP) Before programming the logic board, set the operator’s open and close limits. LEDs on the logic board are provided to assist setting the limits. As each limit is activated the corresponding LED will light up. The abbreviations are Open Limit Switch (OLS), Close Limit Switch (CLS) and Sensing Limit Switch (SLS). Refer to page 19 for limit switch adjustment instructions. When power is applied to the operator, the following LED’s will illuminate: STOP, CLOSE, OPEN, LMEP, 24Vac, RADIO, DATA, TIMER ENABLE, OLS MID, SLS, CLS, and MAS. Once the power up process is completed (approximately 2-3 seconds) only the appropriate LED’s will continue to be lit (i.e., STOP, 24Vdc, limit LED(s) if limit(s) is activated). NOTE: When the power up process is over, the MAS LED will blink a code indicating the version of firmware. If the selector dial is in the DIAG, OPTN, or PROG position, the MAS will not provide this code. After the code has been provided the MAS LED will go out. Open, Close and Stop buttons are mounted directly on the logic board. Thus, making it easy to program as well as have door control at the electrical box. Either the stop control or a jumper MUST be wired between terminals 4 and 5 for the on board push buttons to function. LOGIC BOARD OVERVIEW DATA SLOT Optional Auxiliary Card Receptacles SLOT 24VAC Motor Direction Jumper MID 3-PHASE MOTOR DIRECTION Radio Learn Button OLS 1-PHASE STD REV Maximum Run Timer Button 14 POWER 24VAC 13 TIMER DEFEAT 12 COMMON 11 MAS CLS MRT MID TTC TIMER ENABLE LMEP: EDGE: Open Button OPEN CLOSE Mid Stop Learn Button TS E2 FSTS D1 DIAG C2 OPTN Stop Button Control Wiring Terminal Block PROG B2 RELAY RELAY Selector Dial (used for programming and selecting wiring type) COMMON Close Button PROGRAMMING STOP Timer-To-Close Learn Button Maintenance Alert System Button for Programming 10 SLS RADIO Single Phase & Three Phase Jumper SBC Main Motor Control Harness Connection 27 Programming DETERMINE AND SET WIRING TYPE PROGRAMMING Read the descriptions of the different wiring types to determine which setting will be correct for each application. Once the wiring type is determined, set the selector dial accordingly. LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP) DEVICE IS REQUIRED A LiftMaster Entrapment Protection (LMEP) device is required for the following wiring types. LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP) DEVICE IS RECOMMENDED A LiftMaster Entrapment Protection (LMEP) device is recommended for the following wiring types. B2 C2 Momentary contact to open, close and stop, plus wiring for sensing device to reverse and auxiliary devices to open and close with open override. Programmable mid stop available with this wiring type. Compatible with 3-Button Station, 1-Button Station, 1 and 3-Button Remote Control. TS (TIMER SECURE) This mode will attempt to close the door from any position except when fully closed, or when a safety input is present. The stop button will not disable the Timer-To-Close at any position. To disable the Timer-To-Close in this mode, installation of a defeat switch is required (see wiring diagram). Momentary contact to open, close, and stop with open override and Timer-To-Close. Every device that causes door to open, including a reversing device, activates the Timer-To-Close. Auxiliary controls can be connected to open input to activate the Timer-To-Close. If the timer has been activated, the open button and radio control can recycle the timer. The Timer-To-Close will function from the programmable mid stop with this wiring type. Compatible with 3-Button Station, 1-Button Station and 1 and 3-Button Remote Control. NOTE: A Programmable “Car Dealer Mode” available. Momentary contact to open, close, and stop, with open override and Timer-To-Close. Every device that causes the door to open, except any sensing edge input device, activates the Timer-To-Close. Auxiliary controls can be connected to open input to activate the Timer-To-Close. If the Timer-To-Close has been activated, the open button and radio control can recycle the timer. The stop button will deactivate the timer until the next command input. The Timer-To-Close will function from the programmable mid stop with this wiring type. Compatible with 3-Button Station,1-Button Station and 1 and 3-Button Remote Control. NOTE: Programmable “Car Dealer Mode” available. FSTS Momentary button contact for open, close and stop programming. User set mid stop. User set Timer-To-Close. The single button station opens the door to the full open limit bypassing the mid stop and activates the Timer-To-Close, putting the operator in TS mode until the door reaches the down limit, or is stopped in travel. At which time the operator enters the B2 mode. Compatible with 3-Button Station, 1-Button Station, 1 and 3-Button Remote Control. A 1-Button remote control in FSTS mode will open only with the Timer-To-Close, bypassing a programmed mid stop. The Timer-To-Close will reset and reverse when closing. Programming E2 D1 Momentary contact to open and stop with constant pressure to close, open override plus wiring for sensing device to reverse. Programmable mid stop available with this wiring type. Compatible with 3-Button Station and 1-Button Station. Momentary contact to open with override and constant pressure to close. Release of close button will cause door to reverse (roll-back feature) plus wiring for sensing device to reverse. Compatible with 3-Button Station. Constant pressure to open and close with wiring for sensing device to stop. Compatible with 2 or 3-Button Station. SELECTOR DIAL E2 TS FSTS D1 DIAG C2 OPTN B2 PROG IMPORTANT NOTES: 1. External interlocks may be used with all functional modes. 2. Auxiliary devices are any devices that have only dry contacts. Examples: loop detector, pneumatic or electrical treadles, radio controls, one button stations, pull cords, etc. 3. Open override means that the door may be reversed while closing by activating an opening device without the need to use the stop button first. 4. When the door is in a stopped position other than fully closed, and an LMEP or EDGE input is activated, the Restricted Close (RC) feature will allow a close command when the close button is pressed and held. The operator will begin closing after 5 seconds. If the close button is released the door will stop. When in E2 mode, the door will move to the fully open position. 28 PROGRAMMING REMOTE CONTROLS WARNING To prevent possible SEVERE INJURY or DEATH: • Install a LiftMaster Monitored Entrapment Protection (LMEP) device. • NEVER permit children to operate or play with door control push buttons or remote controls. WA • Activate door ONLY when it can be seen clearly, is properly CAUTION adjusted and there are no obstructions to door travel. • ALWAYS keep door in sight until completely closed. NEVER permit anyone to cross the path of closing door. Built in 3-channel, Security✚ 2.0TM radio receiver that allows you to add as many as 90 remote control devices and as many as 30 touch code devices. NOTE: The following programming requires a LiftMaster Monitored Entrapment Protection (LMEP) device. 3. Press and release the RADIO button to complete the programming. The RADIO programming mode will exit if no activity is performed within 30 seconds. The MAS and RADIO LED’s will flash briefly to indicate the RADIO has exited the programming mode for remote controls and touch code devices. The RADIO will remain in program mode for another 150 seconds for MyQ devices and then will completely exit with no activity. STANDARD REMOTE CONTROL 1. To enter programming press and release the RADIO button on the logic board (RADIO LED will light). 2. Press and hold the remote control button until the RADIO LED flashes rapidly, then release remote control button. The RADIO LED will then remain on solid after releasing the button. Repeat to add additional remote control(s). AVERTISSEMENT AVERT NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or modifications of this transceiver are prohibited. THERE ARE NO USER SERVICEABLE PARTS. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC rules and IC RSS-210. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. ATTENTION SLOT SINGLE BUTTON REMOTE CONTROL PROGRAMMED AS A SINGLE BUTTON CONTROL (SBC) This function programs a remote control as a wireless single button control. This function will work in the following modes: In B2 mode, operation is OPEN/STOP/CLOSE/REVERSE/STOP. In T and TS modes, operation is OPEN/STOP/CLOSE/REVERSE/ STOP and Timer-To-Close start/refresh. NOTE: If Car Dealer mode is enabled, SBC will be open only stopping at the Open Mid-Stop. In FSTS mode, operation is OPEN with Timer-To-Close start/refresh only, bypassing a programmed Open Mid Stop. 1. Press and release the RADIO button on the logic board (RADIO LED will light). 2. Press and release the SBC externally wired button or TTC on the logic board (RADIO LED flashes rapidly and then remains on solid). 3. Press and hold the remote control button until the RADIO LED flashes rapidly. The RADIO LED will then remain on solid after releasing. 4. Press and release the RADIO button on the logic board (RADIO LED flashes rapidly and then turns off). The programming mode is exited if no activity is performed within 30 seconds The MAS and RADIO LED’s will flash briefly to indicate the RADIO has exited the programming mode for remote controls and touch code devices. The RADIO will remain in program mode for another 150 seconds for MyQ® devices and then will completely exit with no activity. NOTE: Single button remote control is not supported with D1 and E2 wiring modes. C2 mode will only open and stop while opening. AVER SLOT RADIO STD REV OLS MOTOR DIRECTION MID SLS CLS ADVERTENCIA RADIO MID TT TS E2 D1 C2 B2 RELAY RELAY TO ERASE REMOTE CONTROLS Press and hold the RADIO button on the logic board until the RADIO LED flashes rapidly (approximately 5 seconds). All remote controls will be erased. 29 ADVE Programming PROGRAMMING PRECAUCIÓN MRT ADV PROGRAMMING REMOTE CONTROLS REMOTE CONTROL PROGRAMMING FEATURE Program Remote Controls from the 3-button control station (3BCS). This feature allows the user to add additional remote controls from the 3BCS. By default the remote control learn option is off. NOTE: Requires access to the operator electrical box to enable or disable this feature. To turn this feature on: 1. Turn the SELECTOR DIAL to PROG. 2. Press and release the RADIO button. The RADIO LED will be lit. 3. Press and release the MID button. The RADIO LED will flash quickly 6 times. 4. Press and release the RADIO button. The RADIO LED will turn off. 5. Return the SELECTOR DIAL to the desired wiring type. To add remote controls from the 3BCS: 1. With the door in the fully closed position (close limit activated), press and hold STOP. 2. While holding STOP, press and hold CLOSE. 3. While holding STOP and CLOSE, press and hold OPEN. 4. Release all three buttons once the MAS LED has lit. 5. Learn a remote control by one of the following methods: a. Programming a standard single button/single function remote control, push and hold the remote control button until the MAS LED goes out. Repeat steps 1 through 4 to add additional remote controls. b. Programming a 3-button/three function remote control (OPEN/CLOSE/STOP), first push the button on the 3BCS (Example: OPEN) and then press and hold the button on the remote control (Example: large button) that you want to correspond with the selected (Example: OPEN) command until the MAS LED flashes and goes out. Repeat steps 1 through 4 to add additional buttons (CLOSE AND STOP). To turn this feature off: 1. Turn the SELECTOR DIAL to PROG. 2. Press and release the RADIO button. The RADIO LED will be lit. 3. Press and release the MRT button. The RADIO LED will flash quickly 3 times. 4. Press and release RADIO button. The RADIO LED will turn off. 5. Return SELECTOR DIAL to desired wiring type. NOTE: Restoring the operator to Factory Default (see RESETTING FACTORY DEFAULTS) will also disable this feature. The remote controls will still be learned. NOTE: The following programming requires a LiftMaster Monitored Entrapment Protection (LMEP) device. Your Security✚ 2.0TM or dip switch remote control can be programmed to operate as a 3-button wireless control station: the large button will open the door, the middle button will close the door, and the third button will stop the door’s movement. You may set up this feature as follows: 1. To enter programming press and release the RADIO button on the logic board (the RADIO LED will light). 2. To program the OPEN button to a remote control press and release the OPEN button on the logic board. The RADIO LED will flash and then stay on solid. Then press the corresponding button on the remote control. The RADIO LED on the logic board will flash, this confirms that the remote control has been programmed. (By programming the remote you use 1 channel of the 90 channels on the radio receiver.) 3. To program the CLOSE button to a remote control press and release the CLOSE button on the logic board. The RADIO LED will flash and then stay on solid. Then press the corresponding button on the remote control. The RADIO LED on the logic board will flash, this confirms that the remote control has been programmed. (By programming the remote you use 1 channel of the 90 channels on the radio receiver.) 4. To program the STOP button to a remote control press and release the STOP button on the logic board. The RADIO LED will flash and then stay on solid. Then press the corresponding button on the remote control. The RADIO LED on the logic board will flash, this confirms that the remote control has been programmed. (By programming the remote you use 1 channel of the 90 channels on the radio receiver.) 5. After learning remote controls press the RADIO button on the logic board (RADIO LED will turn off). NOTE: If no activity within 30 seconds, the MAS and RADIO LED’s will flash briefly to indicate the RADIO has exited the programming mode for remote controls and touch code devices. The RADIO will remain in program mode for another 150 seconds for MyQ® devices and then will completely exit with no activity. DATA SLOT Open MER NABLE EDGE: MOTOR DIRECTION MID 24VAC 13 TIMER DEFEAT 12 COMMON 11 MAS 10 SLS CLS CLOSE STOP 3-PHASE OLS 1-PHASE STD REV CLOSE MRT MID TTC TIMER ENABLE LMEP: EDGE: OPEN RADIO CLOSE STOP STOP COMMON TS E2 FSTS D1 DIAG C2 OPTN COMMON PROG B2 RELAY RELAY Programming 14 POWER OPEN Stop PROGRAMMING 24VAC Close SLOT OPEN SBC 30 PROGRAMMING MyQ® DEVICES (OPTIONAL) To Program MyQ Devices: 1. To enter proramming mode, press and release the RADIO button on the logic board (the RADIO LED will light). 2. To program the MyQ device, place the MyQ device into learn mode (see instructions for the specific MyQ device). 3. When the programming is complete the RADIO LED will turn off. NOTE: If the programming is not completed within 3 minutes, the program mode will be exited and the RADIO LED will turn off. To Erase All MyQ Devices: 1. Press and release the RADIO button on the logic board (the RADIO LED will light). 2. Press and hold the MAS button for 5-seconds. The RADIO LED will flash for approximately 5-seconds and the RADIO LED will turn off. 3. All MyQ devices are now erased. To Erase One MyQ Device: 1. See instructions for the specific MyQ device to erase the programming. 2. When the erase is complete, the MyQ device will be erased on the operator. The operator does not need to be reprogrammed to erase the MyQ device. NOTE: Power the operator to complete the erase operation. MAINTENANCE ALERT SYSTEM (MAS) programmed and the CLOSE button LED will flash once for every 3 month increment programmed. To view how many cycles have elapsed since the last time the MAS was programmed, set the selector dial to DIAGNOSTIC and press the MAS button. Press the OPEN button; the OPEN LED will flash once for every 5,000 cycles that has elapsed. Press the CLOSE button; the CLOSE LED will flash once for every (3) months that has elapsed. Press the MAS button to exit. Turn the selector dial back to desired wiring type. SELECTOR DIAL TS E2 FSTS D1 DIAG OPTN C2 PROG B2 Operation will vary depending on wiring type E2 TS FSTS D1 DIAG OPTN C2 PROG B2 3-BUTTON CONTROL STATION Maintenance Alert LED OPEN CLOSE STOP Special Notes about MAS: A 5th wire must be run to the control station to activate the MAS LED. The MAS LED on the logic board is always enabled. When the operator is serviced after the MAS LED has started to flash, repeat the setup procedure to program in the Press This number or cycles desired until the next service visit OR press and OPEN hold the MAS button for 5 seconds in the PROGRAM mode to reset the MAS with its current programmed value. To disable the MAS, follow the programming procedure above and press the STOP button CLOSE to reset the counter to zero. Every time the operator leaves the close limit is counted as one cycle. STOP To view how many cycles are programmed into the MAS, set the selector dial to DIAGNOSTIC and press the MAS button. The OPEN button LED will flash once for every 5,000 cycle increment 31 To Get This Adds 5,000 cycles to Maintenance Alert System Activation Counter. Adds 3 Months to Maintenance Alert System Activation Timer. Clears memory, sets Maintenance Alert System Activation Counter to 0 cycles and 0 months. Programming PROGRAMMING Feature: An internal cycle counter will activate a flashing LED on the 3-button control station when the preset number of cycles or months has elapsed (whichever occurs first). Setting this feature is optional. By default this feature will never activate. Logic 5 operators incorporate a self diagnostic feature built into the MAS LED. In addition to indicating when routine maintenance is due, the MAS LED can be used to troubleshoot some problems with the operator. Benefit: The Maintenance Alert System (MAS) assists the installing dealer in setting up a routine maintenance program. Once programmed, the MAS notifies the end user (with a flashing LED on the 3-button station) when a preset number of cycles/months has elapsed and scheduled maintenance is due. To Program: 1. Close the door. 2. Turn the selector dial to PROGRAM. 3. Press and release the MAS SET button. 4. Press the STOP button once to clear the MAS memory. 5. Press the OPEN button once for every 5,000 cycles increments. Press the CLOSE button once for every 3 month increments. 6. Press and release the MAS button to complete the programming. The on board LED will flash back the programmed settings. The OPEN LED will flash once for every 5,000 cycles. The CLOSE LED will flash once for every 3 months. 7. Turn the selector dial back to the desired wiring type. NOTE: If MAS LED flashes 2 or more flashes in a row followed by a pause, an operator error occurred. Turn to page 35 to diagnose problem. Example: A door is installed with 30,000 cycle springs and has an annual service contract. To set the MAS, turn selector dial to PROGRAM, press MAS button, press the STOP button to clear the memory and then press the OPEN button 6 times (30,000 cycles) and CLOSE 4 times (12 months). Press the MAS again to complete the programming. Turn the selector dial back to desired wiring type. OPEN MID STOP Feature: The Mid Stop feature is to open the door to a preset point prior to the fully open position. Benefit: The door opens to a midpoint between open and close reducing heating and cooling costs. The door will not cycle fully, providing longer door and operator life. To Program: 1. Close the door. 2. Turn selector dial to PROGRAM. 3. Press and release the MID button on logic board. 4. Press the OPEN button, wait until the door reaches the desired mid stop height, then press and release the STOP button. 5. Press and release the MID button to complete programming. 6. Turn selector dial back to desired wiring type. NOTE: A momentary open command will open the door fully from the Mid Stop position. Once at the Mid Stop, photoelectric sensors and other entrapment protection devices will not open the door beyond the mid stop position, except in E2 mode. The Timer-ToClose will work from the Mid Stop. To clear the Mid Stop set the selector dial to PROG and press and hold the MID button for 5 seconds. The MID LED will flash rapidly and turn off once the Mid Stop has been cleared. Turn selector dial back to desired wiring type. SELECTOR DIAL TS E2 FSTS D1 DIAG OPTN C2 PROG B2 Operation will vary depending on wiring type TS E2 FSTS D1 DIAG OPTN C2 PROG B2 WARNING To prevent possible SEVERE INJURY or DEATH: • Install a LiftMaster Monitored Entrapment Protection (LMEP) device. • NEVER permit children to operate or play with door control push buttons or remote controls. WA • Activate door ONLY when it can be seen clearly, is properly CAUTION adjusted and there are no obstructions to door travel. WA • ALWAYS keep door in sight until completely closed. NEVER permit anyone to cross path of closing door. PROGRAMMING TIMER-TO-CLOSE Feature: Timer automatically closes door after preset time. All entrapment protection devices must be unobstructed. Benefit: The door will automatically close after preset amount of time. Great for apartment buildings, fire stations and other applications where the end user wants the door to close automatically after a specified amount of time. Requirements: Must have at least one LiftMaster Monitored Entrapment Protection (LMEP) device installed (refer to page 20). Wiring type must be set to TS, T or FSTS. TO PROGRAM MANUALLY (METHOD 1): 1. Close the door. 2. Turn the selector dial to PROGRAM. 3. Press and release the TIMER button on the logic board. 4. Press and release the STOP button to clear the timer. 5. Press and release the OPEN button for every second the operator should wait before attempting to close the door. Press and release the CLOSE button for every 15 seconds the operator should wait before closing the door. 6. Press and release the TIMER button to complete programming. The OPEN/CLOSE button LEDs will flash to confirm the timer setting. The OPEN LED will flash once for every second programmed and the CLOSE LED will flash once for every 15 seconds programmed. 7. Turn the selector dial to desired timer wiring type (TS ,T or FSTS). Example: To close the door after 70 seconds. Turn selector dial to PROGRAM, press and release the TIMER button, press and release the STOP button to clear the timer, press and release the CLOSE button four times for 60 seconds and press and release the OPEN button 10 times for 10 seconds. Press the TIMER button to finish programming the timer. Turn selector dial to desired timer wiring type. (TS, T, FSTS). AVERTISSEMENT ATTENTION SELECTOR DIAL E2 32 FSTS Operation will vary depending on wiring type E2 D1 DIAG D1 C2 OPTN C2 B2 Programming TS PROG B2 TS FSTS DIAG OPTN PROG AVERT AVERT TIMER-TO-CLOSE PROGRAM TIMER-TO-CLOSE BY EXAMPLE (METHOD 2): TO PROGRAM: 1. Close the door. 2. Turn the selector dial to PROGRAM. 3. Press and hold TIMER button for 5 seconds until OPEN and OLS flashes then release. 4. Press and release the OPEN button and wait for the door to reach full open or mid stop position. 5. Wait for desired amount of time to pass. (An internal stop watch starts counting when the door stops moving.) 6. Press and release the TIMER button, CLOSE button or STOP button to stop the timer. (TIMER SET LED will turn on.) 7. Turn the selector dial to the desired wiring type (T, TS, FSTS). NOTE: To read back the Timer-To-Close setting, turn the selector dial to DIAGNOSTIC and press the TIMER button. The OPEN LED will flash once for every second programmed and the CLOSE LED will flash once for every 15 seconds programmed. In T Mode, timer can be deactivated from the open position by pressing the STOP button. The timer will be reactivated on the next operation command. The STOP button WILL NOT deactivate the timer in the TS mode. To deactivate the timer for more than one cycle in T mode or in TS mode, attach a defeat switch to 11 and 12 (COMMON and TIMER DEFEAT). SELECTOR DIAL TS E2 FSTS D1 DIAG C2 OPTN PROG B2 Operation will vary depending on wiring type TS E2 FSTS D1 DIAG OPTN C2 B2 PROG CAR DEALER MODE Feature: The car dealer mode uses the SBC (Single Button Control input) to bring the door from a closed position to the programmed Open Mid-Stop position and keep it at that location even with multiple inputs. Benefit: Provides energy cost savings by limiting the door opening height. Requirements: This feature works in conjunction with the programmable Timer-To-Close feature. To enable this feature you must first connect a treadle, photoelectric sensor or loop detector accessory to the SBC input and must have at least one LiftMaster Monitored Entrapment Protection (LMEP) device installed (refer to page 20). Wiring type must be set to TS or T. TO PROGRAM: 1. Start with the door in the closed position. 2. Turn the SELECTOR DIAL to PROG. 3. Push the TIMER button and release (Green Timer LED will be lit). 4. Push the MID button and release. This turns on the Car Dealer Mode. (The GREEN TIMER LED will flash 6 times indicating the Car Dealer Mode is turned on.) 5. Push the TIMER button and release. 6. Turn the SELECTOR DIAL to the desired wiring type (TS or T). NOTE: To disable the Dealer Mode follow steps 2 and 3, then press the MRT button and release. (The GREEN TIMER LED will flash 3 times indicating that the Car Dealer Mode is off.) SELECTOR DIAL TS E2 FSTS D1 DIAG OPTN C2 PROG B2 E2 D1 C2 B2 33 PROGRAMMING Operation will vary depending on wiring type TS FSTS DIAG OPTN PROG Programming MAXIMUM RUN TIMER (MRT) Feature: The operator can learn the time it takes to open or close the door plus and an additional 10 seconds. Benefit: If the operator does not meet its open or close limit within the set time it will stop, limiting damage to the door and operator. To Program: NOTE: The default setting for the MRT is 90 seconds. In the event the application requires the MRT be manually learned for a longer duration follow steps below. 1. Start with the door in the closed position. 2. Set the selector dial to PROGRAM. 3. Press and release the MRT button on logic board. 4. Press the OPEN button and wait for the door to reach the full open limit. 5. Once the door has reached the open position, programming is complete. 6. Turn dial to desired wiring type. NOTE: To reset MRT only, turn selector dial to program and press and hold the MRT button until the MAS led flashes rapidly. SELECTOR DIAL TS E2 FSTS D1 DIAG OPTN C2 PROG B2 Operation will vary depending on wiring type TS E2 FSTS D1 DIAG C2 OPTN PROG B2 RESETTING FACTORY DEFAULTS CLEARING MEMORY PROGRAMMING To reset most of the user installed settings back to factory defaults: 1. Turn the selector dial to DIAGNOSTIC. 2. Press and hold the STOP button for 5 seconds. The MAS LED will flash momentarily when the factory defaults have been restored. 3. Return the selector dial to the desired wiring type. Factory Defaults: a. Timer-To-Close = 0 seconds. b. The Mid Stop is deactivated. c. The Maintenance Alert System is deactivated. d. The Maximum Run Timer is set to 90 seconds. e. Car Dealer Mode is deactivated. f. The remote controls and MyQ® devices will still be learned. g. Remote control programming via the 3-button station. h. The LiftMaster Monitored Entrapment Protection (LMEP) device will be unprogrammed. NOTE: Life of Operator feature (Odometer/Cycle Counter) and programmed remote controls and MyQ devices are not cleared. Programming 34 SELECTOR DIAL TS E2 FSTS D1 DIAG OPTN C2 B2 Operation will vary depending on wiring type PROG E2 D1 C2 B2 TS FSTS DIAG OPTN PROG WARNING WARNING MAINTENANCE MAINTENANCE SCHEDULE CAUTION WARNING For use with Maintenance Alert System. Check at the intervals listed in the following chart: ITEM Drive Chain To avoid SERIOUS personal INJURY or DEATH: • Disconnect electric power BEFORE performing ANY adjustments or maintenance. • ALL maintenance MUST be performed by a trained door systems technician. PROCEDURE EVERY MONTH Check for excessive slack. Check and adjust as required. Lubricate. z6 AVERTISSEMENT Sprockets Check set screw tightness. Clutch EVERY 3 EVERY 6 EVERY 12 MONTHS OR MONTHS OR MONTHS OR 5,000 CYCLES 10,000 CYCLES 20,000 CYCLES AVERTISSEMENT Check and adjust as required. ATTENTION Belt Check condition and tension. Fasteners Check and tighten as required. Manual Disconnect Check and operate. Bearings and Shafts Check for wear and lubricate. LiftMaster Monitored Entrapment Protection (LMEP) Check alignment and functionality. AVERTISSEMENT z6 6 Use SAE 30 Oil (Never use grease or silicone spray). • Do not lubricate motor. Motor bearings are rated for continuous operation. • Do not lubricate clutch or V-belt. Repeat ALL procedures. z Inspect and service whenever a malfunction is observed or suspected. HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA Installation and service information are available. Call our TOLL FREE number: 1-800-528-2806 www.liftmaster.com ADVERTENCIA ADVERTENCIA LIFE OF OPERATOR FEATURE (ODOMETER/CYCLE COUNTER) The operator is equipped with an odometer to show how many months and cycles the operator has performed from the time it as installed. This feature can help determine how long the operator has been in service. 1. Start with the door in the closed position. 2. Turn the SELECTOR DIAL to DIAG (diagnostic mode). 3. Press and release the MAS button on the logic board. 4. Press and release the MRT button on the logic board. 5. The open and close lights will flash. OPEN for every 5,000 cycles and CLOSE for every 3 months. 6. Return the SELECTOR DIAL to the desired wiring type. NOTE: If the operator has not reached 5,000 cycles or 3 months, there will be no indications. ADVERTENCIA PRECAUCIÓN A solenoid brake is available as an option for some models. The brake is adjusted at the factory and should not need additional adjustment for the life of the brake assembly. Inspect the brake pad and replace brake assembly when necessary. NOTE: Your operator may look different than the operator shown. 35 Maintenance MAINTENANCE BRAKE (IF PRESENT) TROUBLESHOOTING DIAGNOSTIC CHART TROUBLESHOOTING The logic board has several LEDs to assist in the installation and troubleshooting of the operator. The following chart should assist in verifying the operator is functioning properly. Turn the selector dial to DIAGNOSTIC to keep the door from moving while troubleshooting. LED COLOR DEFINITION Power Green Indicates that power is being generated for the logic board. Stop Green Indicates a closed circuit between common and terminal 5. Pressing stop should turn off this LED. Open Yellow Indicates a closed circuit between common and terminal 7. Pressing the open button should turn ON this LED. Close Yellow Indicates a closed circuit between common and terminal 6. Pressing the close button should turn ON this LED. LMEP Green Solid on indicates LMEP learned. Flashing indicates sensors need to be re-connected or activated, or unlearned if removed**. Solid off indicates no sensors learned. Timer Defeat Yellow Solid on indicates a closed circuit between common and terminal 12. Timer-To-Close will not close. OLS Yellow Pressing the Open Limit Switch should turn ON this LED. Indicates the Open Limit Switch is activated. CLS Yellow Pressing the Close Limit Switch should turn ON this LED. Indicates the Close Limit Switch is activated. SLS Yellow Pressing the Sensing Limit Switch should turn ON this LED. Indicates the Sensing Limit Switch is activated. Edge Yellow Indicates a closed circuit between common and terminal 8. Pressing the edge should turn ON this LED. Mid Stop Yellow Solid on indicates door is stopped on up or down mid stop. Flashing indicates MID STOP is being set. Timer Enabled Green Solid on indicates TIMER is programmed and will activate from open or mid stop position. Flashing indicates Timer is counting down and door will close after preset time. Each flash represents 1 second of programmed time. SBC Yellow Indicates a closed circuit between common and terminal 1. Pressing the single button control station should turn ON this LED. MAS Yellow Indicates the Maintenance Alert System has been activated or an error code has been triggered. Relay A Yellow Indicates open or close command has been given to the motor. LED turns on when OPEN/CLOSE button is pressed. Relay B Yellow Indicates open or close command has been given to the motor. LED turns on when OPEN/CLOSE button is pressed. DATA Green Indicates communication between the Logic 5 board and optional TLS1CARD. ** RESTRICTED CLOSE. This method will allow you to close the door when LMEP device(s) are no longer working. Press and hold the CLOSE button until the door reaches the closed limit. If the CLOSE button is released before the door reaches the closed limit the operator will stop and the procedure will need to be repeated to fully close the door. Troubleshooting 36 TROUBLESHOOTING GUIDE FAULT THE OPERATOR WILL NOT RESPOND TO ANY COMMANDS POSSIBLE CAUSE a) No power supply FIX ➤ Verify primary line voltage from power source. Green POWER LED must be on. b) Operator control station is wired wrong ➤ Use the OPEN, CLOSE and STOP LEDs to help check correct wiring. Verify that the board is accepting commands by using the onboard station. Green LED next to stop button must be on. c) Interlock switch is activated ➤ Check Interlock(s). If more than one external interlock is present they must be wired in series. Green LED next to stop button must be on. d) Dial still in programming, option, ➤ Set dial to desired wiring type. or diagnostic mode e) Motor is malfunctioning ➤ Verify proper voltage getting to the motor (Check motor name plate). f) Motor thermal overload tripped ➤ Check to see if motor is hot. Allow motor to cool before attempting to move door. Cycle operator in constant pressure one full cycle open and close to reset fault. g) Possible accessory malfunction ➤ Disconnect all devices, reattach them one at a time testing for a failure after each one is replaced. h) Power Board may need to ➤ When the OPEN or CLOSE button is pressed, Relay A or B LED should be replaced turn on and the door should move in the corresponding direction. If Relay A or B lights and the door does not move, the Power Board may need to be replaced. i) Possible logic board failure ➤ Replace logic board. a) Loose secondary wiring connections or a faulty control transformer b) Hoist interlock switch ➤ Repair or replace connections or control transformer. STOP BUTTON LED IS NOT ON a) Control station not connected or wired correctly b) Interlock switch ➤ Check wiring to control station. THE DOOR WILL MOVE ABOUT A FOOT THEN STOP. AFTER STOPPING, ONLY CONSTANT PRESSURE COMMANDS WILL MOVE THE DOOR a) RPM sensor is not connected properly or may need to be replaced ➤ Check the RPM assembly for loose connections. Check that RPM wheel POWER LED IS NOT ON b) Clutch slipping ➤ Check interlock. Verify the manual release chain is not engaged. ➤ Check interlock switch(es) for continuity. is turning when operator is running. Check for foreign matter blocking optical lens. ➤ Replace RPM sensor. ➤ Adjust clutch and verify that door is not binding. THE DOOR WILL MOVE The Maximum Run Timer is not set MOST OF THE WAY correctly TOWARDS A LIMIT THEN STOP. AN EXTRA OPEN OR CLOSE COMMAND IS ABLE TO GET DOOR TO COMPLETE CYCLE ➤ Manually reprogram the Maximum Run Timer (page 34). There may be a Mid Stop set THE DOOR WILL OPEN SOME BUT NOT COMPLETELY. AN EXTRA OPEN IS ABLE TO GET THE DOOR TO OPEN COMPLETELY ➤ Check to see if the Mid Stop LED is on. Clear the Mid Stop by turning THE DOOR WILL OPEN BUT a) The LMEP attached is obstructed WILL ONLY CLOSE AFTER or activated A FIVE SECOND DELAY WITH CONSTANT PRESSURE ON THE CLOSE BUTTON (RESTRICTED CLOSE MODE) b) The logic board thinks that the direct connect photoelectric sensors are attached and blocked ➤ If the on board LMEP LED is flashing, the photoelectric sensor are OR reset the factory defaults (page 34). the selector dial to program. Press and hold the MID STOP button for 5 seconds. Return dial to desired wiring type. To reset Open Mid Stop refer to page 32. ➤ Unlearn the photoelectric sensors from the memory by resetting factory defaults. 37 Troubleshooting TROUBLESHOOTING misaligned or not connected. Remove any obstructions, check the entrapment protection device wires for continuity and shorts. If more than one LMEP is installed with the use of a CPS3CARD the LMEP will not flash when one of the LMEP’s is blocked. TROUBLESHOOTING ERROR CODES by a pause, an operator error has occurred. To view how many errors currently exist, turn the selector dial to DIAGNOSTIC and press the OPEN button. To read out each individual error code (if more than one exists) press CLOSE. It is possible to have more than one error at a time. The chart below can assist with identifying the flashes on the MAS LED. TROUBLESHOOTING Logic 5.0 operators incorporate a self diagnostic feature built into the MAS LED. In addition to indicating when routine maintenance is due, the MAS LED can be used to troubleshoot some problems with the operator. If the MAS LED is flashing on and off rapidly, the Maintenance Alert System has been triggered and the schedule operator service is due. If the MAS LED flashes 2 or more pulses in a row followed ERROR CODE DISPLAY DESCRIPTION EFFECT CORRECTION E1 1 blink MAS triggered (cycles or months) None normal operation Reset MAS (page 31). E2 2 blinks No RPM input during opening The door only responds to constant pressure commands Clutch is slipping, adjust clutch, or verify RPM sensor connection or replace RPM sensor. NOTE: To relearn the RPM sensor, move the door with a constant pressure command. The door will stop once relearned and normal operation will resume. E3 3 blinks (MRT) Maximum Run Time timed out The door stops before reaching set open or close limit(s) First check Operator for any faults (i.e., Bad Limit switch), manually learn Max Run Timer (page 34) OR reset factory defaults (page 34). E4 4 blinks Obstruction sensed or lost RPM sensor input on closing Operator will reverse to OPEN position Remove obstructions, check sensing devices, possible clutch slippage. E5 5 blinks Stuck button pressed for greater than 2 minutes Stuck button on 3-button station will not respond Stuck button must be unstuck before it will be recognized as an input. E6 6 blinks Invalid option card plugged into option card receptacles Option card will not function properly Refer to accessories page for list of supported option card(s). E7 7 blinks LiftMaster Monitored Entrapment Protection (LMEP) device faulted or removed for greater than 2 minutes Normal operation (5 second constant pressure override required to close) Cleared when entrapment protection device is cleared or connected. E8 8 blinks Brownout Detected Operator will run as long as enough power is present 1. Check AC line for voltage. 2. Check transformer secondary for low voltage. Too many accessories may be connected to the transformer. E9 Flash on start of movement Motor movement at invalid time Operator will continue to function normally for 5 operations and then default to a constant pressure mode Check relays and the drive circuitry to ensure that they are turning off. Operator must know that they are turning off. Operator must run correctly for two starts for the error to be cleared. E10 10 blinks Motor Phase Jumper changed while unit is not in programming mode The phase will not change Enter programming mode and move phase jumper to change phase. NOTE: Error codes take priority over normal MAS LED operation. Error codes will repeat on the MAS every 1.5 seconds until cleared. There may be more than one error present, but only the highest priority will flash. If the highest error is cleared, the next highest will flash. All errors self-correct when the corrective action is taken and a reset is not needed. Troubleshooting 38 TROUBLESHOOTING RADIO FUNCTIONALITY The error codes will display at the radio LED. NOTE: Radio receiver is compatible with SECURITY+ 2.0 remotes and touch code devices. ERROR CODE DISPLAY R1 Quick Flash No response from the remote. Unlearned remote A user tries to use a remote, but the RADIO LED only flashes briefly and there is no response from the operator. Try re-learning the remote (page 29). R2 No LED activity No response from the remote. Cannot recognize remote A weak signal caused by a discharged battery or outside interference with the remote(s) - OR - the remote(s) being learned is not compatible with the operator. Antenna not installed or damaged. Replace battery - OR eliminate interference - ORobtain a qualified remote - ORcheck antenna connections. R3 Radio LED turns off after 30 seconds The remote cannot be learned. Cannot recognize remote A weak signal caused by a discharged battery or outside interference interfering with the learn process - OR - the remote(s) being learned is not compatible with the operator. Antenna not installed or damaged. Replace battery - OR eliminate interference - ORobtain a qualified remote - ORcheck antenna connections. R4 2 blinks The remote cannot be learned. Receiver memory full A user enters RADIO function learning mode but there is no space left to add another remote. Erase all learned remotes and re-learn the desired remote. R5 3 blinks The remote cannot be learned. Duplicate remote A user enters RADIO function learning and selects the function to be learned. When the remote button is pressed for learning, a search reveals that remote is already learned. This remote already has a function associated with it. To change the function, erase all learned remotes and re-learn the desired remote. No entrapment protection device present A sensing device is required to close via constant pressure. Must connect a LiftMaster Monitored Entrapment Protection (LMEP) device. R6 SYMPTOM POSSIBLE PROBLEM LMEP LED flashes Cannot close via constant pressure in C2, D1 or E2 modes. CORRECTION TROUBLESHOOTING 39 Troubleshooting WIRING DIAGRAMS LOGIC (VER. 5.0) 1 PHASE WIRING DIAGRAM TBD Maintenance Alert LED (RD) (WH) OPEN CLOSE Open STOP Close Sensing Edge Open/Close Single Button OPTN PROG SBC COMMON FSTS SLOT L3 L2 L1 hot neutral SLS B2 C2 D1 E2 RADIO (GY) MOV MOV 115 / 230 VOLT 1PH. POWER IN ground RELAY RELAY MID MRT (OR) (WH) (YE) (PU) (WH) (RD) (GY) (YE) (RD) (WH) (PU) (YE) (OR) (BK) MOTOR DIRECTION STD SLOT CLS MID OLS REV Remove Jumper To Install External Door Interlock (YE) TS TTC 1-PHASE 3-PHASE DIAG STOP CLOSE OPEN TIMER ENABLE EDGE: LMEP: 10 11 MAS COMMON 12 13 TIMER DEFEAT 24VAC POWER C61 C8 TMR DEF SWITCH 14 (BL) (YE) 24VAC Hoist Interlock When Present DATA C1 3-Button Station Stop Refer to page 21 for LiftMaster Monitored Entrapment Protection (LMEP) device connections (WH) COM 120 VAC -24 VAC (YE) (WH) (RD) (PU) (WH) COM CLOSE L/S (GY) NC (WH) RPM Board NC NO (WH) (WH) LOCK SENSOR (see note at left) Wiring Diagrams (RD) COM NO (RD) NO NC NC 40 SAFETY L/S COM (WH) R1 R2 (YE) R3 1 2 3 4 (YE) NOTE: The Lock Sensor switch is located in the chassis. (OR) (WH) COM NO NC (RD) OPEN L/S NO (YE) NOTE: Lock Sensor is provided on Models DJ and DH only, red wire from main harness connects to NC on Bypass L/S and to NO on LOCK SENSOR switch. White wires connect the COM on BYPASS L/S and LOCK SENSOR switch to NC on Open L/S. (WH) WIRING DIAGRAMS +24 VAC 120 / 240 VAC BYPASS L/S External Radio Receiver NOTE: 32 Vdc power supplied from White and Yellow wires located within the electrical box. LOGIC (VER. 5.0) 3 PHASE WIRING DIAGRAM Maintenance Alert LED (RD) (WH) TBD STOP Close 3-Button Station Stop Refer to page 21 for LiftMaster Monitored Entrapment Protection (LMEP) device connections Open/Close Single Button OPTN PROG SBC COMMON FSTS L3 L2 L1 SLOT B2 C2 D1 E2 RADIO SLS RELAY RELAY MID MRT STD SLOT CLS MID OLS REV Remove Jumper To Install External Door Interlock (YE) TS TTC 1-PHASE 3-PHASE DIAG STOP CLOSE OPEN EDGE: TIMER ENABLE MAS LMEP: 10 11 12 COMMON TIMER DEFEAT POWER 24VAC C61 13 TMR DEF SWITCH 14 (BL) (YE) 24VAC Hoist Interlock When Present C8 CLOSE Open Sensing Edge DATA C1 OPEN (OR) (WH) (YE) (PU) (WH) (RD) (GY) (YE) (RD) (WH) (PU) (YE) (OR) (BK) MOTOR DIRECTION (GY) MOV 208/230/460 VOLT 3PH. POWER IN MOV (WH) COM 120 VAC +24 VAC 120 / 240 VAC -24 VAC (WH) (RD) (PU) (WH) COM (WH) (YE) CLOSE L/S (GY) NC RPM Board NC NO (WH) (WH) LOCK SENSOR (see note at left) (RD) NO (RD) SAFETY L/S COM (WH) COM NO NC NC 41 R1 R2 (YE) R3 1 2 3 4 (YE) NOTE: The Lock Sensor switch is located in the chassis. (OR) (WH) COM NO NC (RD) OPEN L/S NO (WH) NOTE: Lock Sensor is provided on Models DJ and DH only, red wire from main harness connects to NC on Bypass L/S and to NO on LOCK SENSOR switch. White wires connect the COM on BYPASS L/S and LOCK SENSOR switch to NC on Open L/S. External Radio Receiver NOTE: 32 Vdc power supplied from White and Yellow wires located within the electrical box. BYPASS L/S Wiring Diagrams WIRING DIAGRAMS (YE) OPEN OPEN ACCESSORIES REMOTE CONTROLS 315MHz ENTRAPMENT PROTECTION DEVICES MONITORED LiftMaster offers a variety of SECURITY✚® Remote Controls for your application needs. Single to 4-Button, visor or key chain. Contact your authorized dealer. 371LM 1-Button SECURITY✚® Remote Control: Includes visor clip. 373LM 3-Button SECURITY✚® Remote Control: Includes visor clip. 333LM 3-Button Tri-Colored Dip Switch Remote Control: Includes visor clip. WPB1LM3 CPS-UN4 Commercial Protector System®: Provides protection on doors up to 45' wide. NEMA-4 rated. CPS-U Commercial Protector System®: Provides protection on doors up to 30' wide. CPS3CARD Option Logic Board: For use when more than one set of photoelectric sensors are required. Also available pre-packaged with a second set of photoelectric sensors; see CPS3 or CPS3-N4 in Commercial Door Operator Product and Accessories Price List for more information. CPS-EI Monitored Sensing Edge Interface: For use with the approved 4-wire edge (see below). Wireless Single Push Button Control SECURITY✚®: Rugged composite housing. (Wireless controls cannot be used in place of hard wired controls.) OPEN WPB3LM3 Wireless 3 Button Control Station SECURITY✚®: 40-34141-1 Rugged composite housing. (Wireless controls cannot be used in place of hard wired controls.) 65ME1234 Miller ME123 4-Wire Sensing Edge: For sectional or rolling doors. 65ME110 Miller ME110 4-Wire Sensing Edge: For rolling grilles and counter shutters. WKP5LM3 (5 4-digit entry codes) WKP250LM3 (250 4-digit entry codes) MOUNTING CHANNELS Wireless Access Control Keypads SECURITY✚®: Rugged composite housing. (Wireless controls cannot be used in place of hard wired controls.) CONTROL STATIONS 02-101 U-Shaped Mounting Channel: For 65ME1234 edge when installed on sectional doors. 65ME123C1 T-Shaped Mounting Channel: For 65ME1234 edge when installed on rolling doors. Fits between L-shaped angles used to construct a bottom bar on rolling doors. OPEN 1-Button Control Station: Steel enclosure. OPEN 02-102 65ME123C OPEN 65ME123CA3 L-Shaped Mounting Channel: For 65ME1234 edge when installed on sectional doors. 2-Button Control Station: Steel enclosure. NON-MONITORED Vehicle Detection System: Pneumatic Sensing Edge Kit with exterior air switch, 2-wire coil cord and 14' air hose. 65-8202 02-103L 3-Button Control Station: Steel enclosure with Maintenance Alert System. 02-110 OPEN CLOSE 65-5202 Key Control Station: Indoor flush mount, NEMA 1 with Stop button. Vehicle Detection System: Pneumatic Sensing Edge Kit with exterior air switch, 2-wire take-up reel (20' extended) and 14' air hose. OPTION CARDS TLS1CARD STOP MOUNTING BRACKETS 10-12360 ACCESSORIES 08-9098 08-9098EZ Heavy gauge steel bracket for vertical or horizontal mount on either front or top of coil on a rolling door. Has a variety of mounting hole patterns compatible with many OEM manufacturers. For use with J, H, DJ, and DH operators. May be welded. AUXCARD Cast iron bracket to mount J, H, DH, DJ, and GH side mount operators on end bracket of a rolling door or grill. For vertical or horizontal mount on either front or top of coil. Cannot be welded. CHAIN Auxiliary Contact Card: The Auxiliary Contact option card has both Normally-Open and Normally-Closed contacts that actuate when the door is idle, opening, or closing. For Jackshaft Type Operators TENSIONERS 71-6023 71-6125 Same as 08-9098, but with adapter plate to hold mounting bolts in place for easy mounting. Timer Light Status Card: The TLS option card provides special functionality to activate and flash auxiliary devices such as lights, bells, and horns/strobes at various door positions, and to provide special timer functions. For 1" shafts. Recommended to properly tension drive chain between operator shaft and door shaft. Same as 71-6023, but for 1-1/4" shafts. MISCELLANEOUS 1A3982 1A4324 Heavy gauge steel bracket for vertical or horizontal mount on either front or top of coil on a rolling door. May be welded. For use with J, H, DJ, and DH operators. 1A4324EZ Same as 1A4324, but with adapter plate to hold mounting bolts in place for easy mounting. Accessories 86LM (15') 86LMT (25') 42 Operator Cover: For use with wall-mounted J, H, GH, DH or DJ operators. Measures 31" x 19" x 18" (L x W x D). Assembly required. Recommended for damp environments where direct spray is present. Required when the operator is installed less than 8 feet above the floor. Antenna Extension Kit: The antenna extension kit can be used with EXT-ANT for maximum radio receiver range. CONTROL CONNECTION DIAGRAM IMPORTANT NOTES: 1. The 3-Button Control Station provided must be connected for operation. 2. If a STOP button is not used, a jumper must be placed between terminals 4 and 5. 3. When adding accessories, install them one at a time and test each one after it is added to ensure proper installation and operation with the Commercial Door Operator. 3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON STANDARD 10 10 2 OR MORE 7 6 4 KEY LOCKOUT 7 6 10 (RED) (RED) (RED) Open Maintenance Alert LED Maintenance Alert LED Close Stop (WHITE) Open Open Close Close Stop (WHITE) Open Maintenance Alert LED Close Stop (WHITE) Stop NOTE: Stop circuit must be wired in series for all stop buttons to function. This may require removal of factory installed jumper bar in the 3-button station. Keyswitch 2 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER STANDARD 2 OR MORE D1 & E2 MODE ONLY D1 & E2 MODE ONLY Open See note 2. Close TIMER DEFEAT SWITCH Open Open Close Close 1 BUTTON STATION OR ANY AUXILIARY DEVICE 11 12 RADIO CONTROLS (WH) (OR) (YE) OPEN / CLOSE 1 4 R1 B2, T, TS & FSTS MODE ONLY Keyswitch R2 EXTERNAL RADIO RECEIVER R3 NOTE: 32 Vdc power supplied from white and yellow wires located within the electrical box. See note 2. NON-MONITORED EDGE SENSOR TO REVERSE OR STOP EXTERNAL INTERLOCK Note: 11 and 4 are both the same common. Either is acceptable. 11 See note 2. Remove Factory Installed Jumper When Interlock is Used Edge Sensor ONE 2 OR MORE All Wiring Types 43 Control Connection Diagram 01-36811 © 2013, The Chamberlain Group, Inc. All Rights Reserved
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Author : NKay Create Date : 2014:02:17 16:36:40-06:00 Modify Date : 2014:02:17 16:37:02-06:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2014:02:17 16:37:02-06:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Format : application/pdf Title : 01-36811.indd Creator : NKay Document ID : uuid:07741142-0943-4484-ba3f-6d11dae0ad99 Instance ID : uuid:ad12a3de-653e-46f6-b778-e588094472fa Producer : Acrobat Distiller 9.5.3 (Macintosh) Page Count : 22EXIF Metadata provided by EXIF.tools