Christie Digital Systems Canada CRMX100 ASSY PCB RF Module User Manual 020 100489 02 LIT TECH REF RFModule
Christie Digital Systems Canada, Inc. ASSY PCB RF Module 020 100489 02 LIT TECH REF RFModule
user manual
DESCRIPTION EL 20 l E AS 09 ED RF Module Technical Reference Information on tro FF 2.4GHz IEEE 802.15.4 Compliant RF Transceiver High Performance and Low-Power 8051 Microcontroller Two Serial Unart Interface 2.4GHz Front End Amplifier Supports RemoTI stack from Texas Instruments 16 General Purpose I/O ports Chip antenna or RP-SMA connector for external antenna Miniature Footprint 35.80 x 23.11 mm Long Range up to 225 meter Max 10 mW output power RoHS compliant • • • • • • • • • • • FEATURES 1, en IA D LL D ocum Y The CRMX-100 RF module is a 2.4GHz IEEE 802.15.4 transceiver designed for proprietary, Zigbee or RF4CE application. The module is based on Texas Instruments CC2530 that combines the excellent performance of a RF transceiver with industry–standard enhanced 8051 microcontroller unit, 128 KB in-system programmable flash memory, 8-KB RAM, and many other features. The RF module incorporates Texas Instrument CC2590 RF Front End power amplifier (PA) and low-noise amplifier (LNA) for increased output power, and improved receiver sensitivity respectively. The module has an option to either be populated with a chip antenna or reverse-polarity SMA connector to be used with an external antenna. The RF module has various operating modes, making it highly suited for systems where ultralow power consumption is required. RF Module Datasheet Technical Reference Information 020-100489-02 Rev. 01 (11-2009) 1 of 8 ABSOLUTE MAXIMUM RATINGS (1) Rating Supply voltage All supply pins must have the same voltage Voltage on any digital pin MAX 3.9 UNIT VDC -0.3 VDD + 0.3, Max 3.9 +10 125 260 VDC dBm °C °C kV 500 -40 According to IPC/JEDEC J-STD-020C All pads, according to human-body model, JEDEC STD 22, method A114 According to charged-device model JEDEC STD 22, method C101 EL 20 l E AS 09 ED Input RF level Storage Temperature Range Reflow soldering temperature ESD(2) MIN -0.3 1) Stress beyond those listed under the Absolute Maximum Ratings may cause permanent damage to device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. on tro IA D LL D ocum Y 2) CAUTION! ESD sensitive device. Precaution should be used when handling the device in order to prevent permanent damage. Min 2405 -40 Max 3.6 2480 85 Unit VDC MHz °C FF Rating Power Supply Voltage (VDD) Input Frequency Ambient Temperature Range 1, en RECOMMENDED OPERATING CONDITIONS PIN DESCRIPTIONS The RF module has 24 edge I/O pins for connecting to a host board. The following table enumerates and defines the RF module pinout. 2 of 8 RF Module Datasheet Technical Reference Information 020-100489-02 Rev. 01 (11-2009) PIN PIN NAME PIN TYPE PIN DESCRIPTION GROUND GND Ground P2_2 General Purpose Digital I/O Port 2_2 P2_1 DI/DO/AI DI/DO/AI P2_0 DI/DO/AI General Purpose Digital I/O Port 2_0 P1_7 DI/DO/AI General Purpose Digital I/O Port 1_7 P1_6 DI/DO/AI General Purpose Digital I/O Port 1_6 P1_5 DI/DO/AI General Purpose Digital I/O Port 1_5 GROUND GND P1_3 DI/DO 11 P1_2 DI/DO General Purpose Digital I/O Port 1_2 Not Connected 14 P0_6 DI/DO 15 P0_5 DI/DO 16 P0_4 DI/DO 17 GROUND GND 18 P0_3 DI/DO 19 P0_2 20 RESET 21 P0_1 FF P0_0 General Purpose Digital I/O Port 1_0 General Purpose Digital I/O Port 0_6 VDD GROUND on tro DI/DO General Purpose Digital I/O Port 0_5 General Purpose Digital I/O Port 0_4 en P1_0 IA D LL D ocum Y 13 24 General Purpose Digital I/O Port 1_3 12 23 Ground Not Connected 10 22 EL 20 l E AS 09 ED General Purpose Digital I/O Port 2_1 Ground DI/DO 1, General Purpose Digital I/O Port 0_3 DI Reset, active low General Purpose Digital I/O Port 0_2 DI/DO General Purpose Digital I/O Port 0_1 DI/DO General Purpose Digital I/O Port 0_0 PI Power Supply Input GND Ground DI= Digital Input DO= Digital Output AI= Analog Input AO=Analog Output PI = Power Input GND = Ground RF Module Datasheet Technical Reference Information 020-100489-02 Rev. 01 (11-2009) 3 of 8 ANTENNA The RF module can either be populated with a chip antenna or Reverse-Polarity SMA connector for an external whip antenna. The regulatory certification will be completed with Yageo Corporation’s 5320 ceramic chip antenna (part# CAN4311153002501K) and also with the PRO-CELL CO., LTD’s dipole antenna (part# RA-A01) with Reverse-Polarity SMA connector. DIMENSIONS: CRMX-100 RF MODULE WITH CHIP ANTENNA on tro FF 1, en IA D LL D ocum Y EL 20 l E AS 09 ED All dimensions are in millimeters, unless otherwise noted. 4 of 8 RF Module Datasheet Technical Reference Information 020-100489-02 Rev. 01 (11-2009) DIMENSIONS: CRMX-100 RF MODULE WITH RP-SMA CONNECTOR on tro FF 1, en IA D LL D ocum Y EL 20 l E AS 09 ED All dimensions are in millimeters, unless otherwise noted. RF Module Datasheet Technical Reference Information 020-100489-02 Rev. 01 (11-2009) 5 of 8 on tro FF 1, en IA D LL D ocum Y PCB KEEP-OUT AREAS EL 20 l E AS 09 ED PCB PAD LAYOUT 6 of 8 RF Module Datasheet Technical Reference Information 020-100489-02 Rev. 01 (11-2009) NOTICE You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user's authority to operate the equipment. EL 20 l E AS 09 ED This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC/IC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. 1) this device may not cause interference and on tro This device complies with Part 15 of the FCC/IC Rules.Operation is subject to the following two conditions: IA D LL D ocum Y 2) this device must accept any interference received, including interference that may cause undesired operation of the device. en FCC/IC RF Radiation Exposure Statement: 1, This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FF Contains FCC ID: XU6-CRMX100 Contains IC: 8691A-CRMX100 RF Module Datasheet Technical Reference Information 020-100489-02 Rev. 01 (11-2009) 7 of 8 EL 20 l E AS 09 ED on tro 1, en IA D LL D ocum Y FF 8 of 8 RF Module Datasheet Technical Reference Information 020-100489-02 Rev. 01 (11-2009)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Producer : GPL Ghostscript 8.63 Keywords : Modify Date : 2009:12:01 11:04:56-05:00 Create Date : 2009:11:27 10:11:34-05:00 Creator Tool : PDFCreator Version 0.9.6 Metadata Date : 2009:12:01 11:04:56-05:00 Document ID : b054d8c3-ddc2-11de-0000-afa779d57d72 Instance ID : uuid:410180d9-da3b-4e0e-8c28-f2d24a12244e Format : application/pdf Title : 020-100489-02_LIT TECH REF_RFModule.fm Creator : nschneider Description : Page Mode : UseOutlines Page Count : 8 Author : nschneider Subject :EXIF Metadata provided by EXIF.tools