ChronoTrack Systems CON-M200-USA1 Mobile RFID 4 Port Data Collection Device User Manual 1
ChronoTrack Systems LLC Mobile RFID 4 Port Data Collection Device Users Manual 1
Contents
- 1. Users Manual 1
- 2. Users Manual 2
- 3. Users Manual 3
Users Manual 1
MiniTrack User Manual ChronoTrack Systems, Inc. 111 East Diamond Avenue Evansville, Indiana 47711 U.S.A. Document # 12471 812-423-7800 Main 314-406-7243 Sales 812-759-7877 Support 812-423-7801 Fax Updated: May 2012 www.chronotrack.com © Copyright 2012 ChronoTrack Systems, Inc. All rights reserved. “ChronoTrack”, “MiniTrack”, “D-Tag”, “B-Tag”, and “D-Tag Interrogator” are trademarks of ChronoTrack Systems, Inc. “Windows” is a registered trademark of Microsoft Corporation in the United States and other countries. All other trademarks used herein are property of their respective owners. ChronoTrack Systems, Inc. makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. ChronoTrack Systems shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of ChronoTrack Systems. ChronoTrack Systems shall not be liable for technical or editorial errors or omissions contained herein. The information is provided “as is” without warranty of any kind and is subject to change without notice. Updated: May 2012 ChronoTrack Systems, Inc. MiniTrack User Manual Index Table of Contents 1. Introduction ...................................................................................................................................................... 1 1.1 1.2 1.3 1.4 Applicable Version .................................................................................................................................... 1 About This Guide ...................................................................................................................................... 1 MiniTrack System Overview ...................................................................................................................... 1 Cautions and Warnings ............................................................................................................................. 2 2. Gator Setup and Configuration .......................................................................................................................... 3 2.1 2.2 2.3 Possible Gator Configurations ................................................................................................................... 3 Positioning and Linking Gators .................................................................................................................. 3 Creating a “Dead Zone” ............................................................................................................................ 4 3. Controller Setup ................................................................................................................................................ 5 3.1 3.2 3.3 3.4 The Controller Interface ............................................................................................................................ 5 Powering ON ............................................................................................................................................ 5 Checking Connected Antennas .................................................................................................................. 6 Swap Battery Power ................................................................................................................................. 6 4. Using the MiniTrack Controller .......................................................................................................................... 7 4.1 4.2 4.3 The Main Screen ....................................................................................................................................... 7 Menu Navigation ...................................................................................................................................... 8 Menu Commands ..................................................................................................................................... 9 4.3.1 4.3.2 4.3.3 4.3.4 4.3.5 4.3.6 4.3.7 4.3.8 4.3.9 4.3.10 4.3.11 4.3.12 4.3.13 4.3.14 4.4 Pre-configuring the MiniTrack ................................................................................................................. 15 4.4.1 4.4.2 4.4.3 4.4.4 4.4.5 4.5 Creating a Gun Start Timestamp ................................................................................................................10 Viewing Messages.....................................................................................................................................10 Setting File Markers ..................................................................................................................................10 Server Configuration .................................................................................................................................10 Tools ........................................................................................................................................................11 Low Power................................................................................................................................................12 Dry Mode .................................................................................................................................................12 Setting the Time and Date .........................................................................................................................13 Audio Menu..............................................................................................................................................14 Network Configuration..............................................................................................................................14 Temperature.............................................................................................................................................14 MAC Address ............................................................................................................................................14 Versions....................................................................................................................................................15 Copyright ..................................................................................................................................................15 Fields ........................................................................................................................................................15 Clearing Values .........................................................................................................................................16 Comments ................................................................................................................................................16 File and Directory Names ..........................................................................................................................16 Example....................................................................................................................................................16 Collecting Select Times ........................................................................................................................... 17 4.5.1 Using the Keyboard...................................................................................................................................18 5. Using CCSLite .................................................................................................................................................. 19 5.1 5.2 5.3 5.4 Configuration of CCSLite ......................................................................................................................... 19 Establishing Controller Connections ........................................................................................................ 19 CCSLite Raw Mode .................................................................................................................................. 20 Adding a Firewall Exception for CCSLite................................................................................................... 20 6. Using SimpleClient .......................................................................................................................................... 21 6.1 SimpleClient Operation Modes ............................................................................................................... 21 Updated: May 2012 ii ChronoTrack Systems, Inc. 6.1.1 6.1.2 6.2 6.3 6.4 6.5 6.6 6.7 Index Local Network Mode .................................................................................................................................21 Internet Server Mode................................................................................................................................21 Connecting to the Server and Retrieving Data ......................................................................................... 21 Streaming Data ....................................................................................................................................... 22 Tag Invalidation ...................................................................................................................................... 23 File Formats ............................................................................................................................................ 23 Saving SimpleClient Data......................................................................................................................... 23 Filtering Data .......................................................................................................................................... 24 6.7.1 6.8 6.9 6.10 6.11 6.12 6.13 MiniTrack User Manual Creating Tag Ranges for an Event ..............................................................................................................24 Creating Virtual Points ............................................................................................................................ 24 Creating and Using an Announcer Line .................................................................................................... 25 Loading Controller Files........................................................................................................................... 25 Establishing a Direct Socket Connection with Scoring Software ............................................................... 26 Setting Time Intervals for Pass Counts and Same Tag Observations ......................................................... 26 Creating Time Shifts ................................................................................................................................ 26 6.13.1 6.13.2 6.13.3 6.13.4 Disabled ...................................................................................................................................................26 UTC to Local Timezone ..............................................................................................................................27 Manual .....................................................................................................................................................27 00:00 Start ................................................................................................................................................27 6.14 Renaming Events/Points ......................................................................................................................... 27 6.15 More SimpleClient Functions .................................................................................................................. 27 7. Troubleshooting .............................................................................................................................................. 28 8. Appendix......................................................................................................................................................... 29 8.1 System Specifications.............................................................................................................................. 29 9. Index............................................................................................................................................................... 30 Updated: May 2012 iii ChronoTrack Systems, Inc. MiniTrack User Manual Introduction 1. Introduction MiniTrack is a cost-effective timing and tracking system for use at athletic events, such as a marathon or a road race. ChronoTrack “D-Tag” technology uses specially designed RFID controllers and antennas to track an EPC-certified, UHF RFID tag that is attached to the runner’s foot during the race. Using this system, ChronoTrack Systems, Inc. provides full-service race timing packages, including internationally certified race timers, bibs, tags, and race timing equipment. 1.1 Applicable Version This guide applies to Mini Track Controller software version 5.2.9 and above. 1.2 About This Guide This guide describes how to set up, configure, and use MiniTrack system components to time and track athletic events. This symbol indicates cautions and warnings where necessary. 1.3 MiniTrack System Overview The MiniTrack system is comprised of the components listed below. See System Specifications in the Appendix for more details. • D-Tag Interrogator (“Gator”) or Mat A D-Tag Interrogator, also known as a Gator, is a specially designed modular track that is placed at each timing location. Each Gator is 42 inches long and is connected with other Gators until they span the entire width of the roadway at the designated timing location. • D-Tag Interrogator Core (Antenna) A D-Tag Interrogator Core Antenna fits inside each Gator and reads participant D-Tags as they pass over that portion of track. This information is then sent to the MiniTrack controller. • MiniTrack Controller (Mini Series) A MiniTrack controller stores and reads the RFID data that is recorded by the antennas at its timing location. The MiniTrack controller can support a configuration of up to four Gators (a span of up to 14 feet). • Power Cable and Power Brick The Power Cable and Power Brick enable you to run the MiniTrack controller from an auxiliary battery source. • Cable Set Cable sets include four cables which connect the Gator Core Antennas to the controller. • External Keypad An optional numeric keypad that can be connected to the controller to enable you to manually collect select times (Logitech N305 only). • Client/Server Software The MiniTrack controller enables you to connect to server/client software to tabulate and review results. SimpleClient software that retrieves and manipulates controller data for use in third-party scoring software. CCSLite software that helps establish LAN and Wi-Fi connections with the SimpleClient software. Updated: May 2012 Relevant S/W Ver: 5.2.9 and above ChronoTrack Systems, Inc. 1.4 MiniTrack User Manual Introduction Cautions and Warnings DOT regulations prohibit the shipping of lithium batteries by aircraft or vessel. Shipped controllers that include the Ryobi battery must include the following label: “LITHIUM BATTERIES: FORBIDDEN FOR TRANSPORT ABOARD AIRCRAFT AND VESSEL”. FCC Part 15 Regulations Caution – Any changes or modifications to this system without the express permission of ChronoTrack Systems will void the user’s authority to operate this equipment. Industry Canada Notices (RSS-GEN Issue 3 §7.1.2) English French This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. This radio transmitter IC: 8688A-CONM200USA1 has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le présent émetteur radio IC: 8688A-CONM200USA1 a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur. Impinj A30310-USAOE (5 dBi gain, 50 Ω impedance) Updated: May 2012 Relevant S/W Ver: 5.2.9 and above ChronoTrack Systems, Inc. MiniTrack User Manual Gator Setup and Configuration 2. Gator Setup and Configuration The MiniTrack Controller and modular Gators are versatile and allow for multiple configurations. Timing locations can be configured to be as narrow as 42 inches or as wide as 28 feet of continuous lengths, with one controller covering as much as 14 feet. 2.1 Possible Gator Configurations In preparation for an event, it is important to determine the width of the roadway at the designated timing locations. This information is used to determine which configurations of Gators and controllers will best suit your needs. With the MiniTrack system, a backup line is recommended to increase overall performance of the system and as a fail-safe measure to ensure every tag is read. The following are some possible configurations. Note that spacing is not to scale. Primary and Backup with Two MiniTrack Controllers Mat Length of 14 Feet (4.27 Meters) Mat Separation of 15 Feet (5 Meters) 2.2 Positioning and Linking Gators To position and link Gators, complete the following procedure: 1. Position the Gators on the ground with the cable compartment hinges facing in the direction from which runners will be approaching, and then link the connecting ends together. Primary and backup lines should be spaced 15 feet apart. 2. Insert the Impinj Threshold antenna into the cable compartment of each Gator, placing it in the direction of the controller with the writing on top. The Impinj logo must be readable by the runners for D-Tags; for B-Tag, it must be the opposite direction. 3. Starting with the Gator farthest from the controller, connect the Core antennas together using the appropriate cable set for your configuration. When the connectors tangibly ‘click’, the cables are connected correctly. Updated: May 2012 Relevant S/W Ver: 5.2.9 and above ChronoTrack Systems, Inc. MiniTrack User Manual Gator Setup and Configuration 4. Pass the cables through the Gators using the top trough in the cable compartments. Make sure the cables do not cross over the top of a trough. This can cause the lid of the Gator to close unevenly and possibly damage the cable. 5. Connect the cables from the nearest Gator to the corresponding ports on the controller, matching the color of each cable to the color of the port (Red cable to red port, blue to blue, etc.) The only antenna licensed for use with this controller is the Impinj Threshold Antenna P/N: IPJ-A031-USA0E using the cable sets provided by ChronoTrack Systems LLC. 2.3 Creating a “Dead Zone” In order to avoid cross-reads when lines are placed next to each other (for example, two races finishing at the same location on different ChronoTrack lines) it is necessary to either create an 8′ x 12′ “dead zone” or use a radiant barrier (an insulation material available at most hardware stores). Updated: May 2012 Relevant S/W Ver: 5.2.9 and above ChronoTrack Systems, Inc. MiniTrack User Manual Controller Setup 3. Controller Setup 3.1 The Controller Interface MiniTrack Controllers are housed in crush-proof, waterproof, heat-resistant transport cases. The case also provides lid supports to shield the controller interface during inclement weather. In harsh conditions, you can place controllers in plastic bags for further protection or you can use rain covers. The controllers include an LCD for messages, status and configuration, a TouchPad for menu interaction and LEDs to indicate status and signal events. The MiniTrack controller interface and legend are shown as follows: Power Alert indicator LEDs Menu/message LCD screen Menu/message navigation keys Battery A Status Menu/message navigation keys Toggle battery power Battery B Status Port indicator LEDs Numeric keypad Gun start button Power indicator Side panel Bottom panel 3.2 Powering ON To power ON a controller, slide the power switch located on the upper portion of the side panel. The LCD displays “MiniTrack Loading…”. LCD lights on the interface light up as the controller readies. When the controller is ready, the Main Screen is displayed. Updated: May 2012 Relevant S/W Ver: 5.2.9 and above ChronoTrack Systems, Inc. 3.3 MiniTrack User Manual Controller Setup Checking Connected Antennas The controller side panel contains antenna ports. For each antenna connected, the port light turns on to indicate a connection. Each controller also comes with an RFID Detector card that can be held approximately 6” (15.25cm) from each antenna to confirm that it is operating properly 3.4 Swap Battery Power Remove battery to swap to alternate battery or press the SWAP button on the interface. When AC power is connected, the controller automatically uses AC power, even if batteries are connected. If AC power is disconnected, an alert sounds and a message indicates the controller has switched to battery power (if available). The controller will shut down if no battery power is available and the AC power is disconnected. Updated: May 2012 Relevant S/W Ver: 5.2.9 and above ChronoTrack Systems, Inc. MiniTrack User Manual Using the MiniTrack Controller 4. Using the MiniTrack Controller This section describes the MiniTrack controller menu. Menu commands are organized into six categories: 1. Messages: view/clear alert messages and set markers 2. Server: connect and set the IP address for the ChronoTrack server 3. Tools: controller settings 4. Time: set or synchronize ChronoSync and controller time 5. Audio: turn the audible tag beep setting on/off 6. Network: set controller’s IP address, Netmask and Gateway 7. Status: controller status and version information See Error! Reference source not found. for a table of menu commands. 4.1 The Main Screen After a controller is powered ON, the Main Screen is displayed. System time Last tag read 10:38:16 6912 A 3T Unique count Total count/ Upload count Frequency (select countries only) Elements of the main screen include: • System time: The current system time is displayed in the top left of the Main Screen. To change the system time, see Setting the Time and Date. • Unique count: indicates the total number of unique D-Tags ready by the controller. • Last tag: indicates the most recent tag read. Data is not displayed here until after the accurate time is calculated and assigned for the tag (about five seconds). To clear the tag count, see Zeroing Tag Counts. • Frequency: indicates the frequency currently in use (for models in select countries only). • Total uploaded (U): if connected to the network, the main screen displays the total number of tags uploaded by the controller. • Total count (T): if disconnected, the main screen indicates the total number of tags read by the controller. A tag is read again if a participant passes over the same timing line beyond the five second read window. For example, if the start line is also used as the finish line a tag may be read twice. Updated: May 2012 Relevant S/W Ver: 5.2.9 and above ChronoTrack Systems, Inc. 4.2 MiniTrack User Manual Using the MiniTrack Controller Menu Navigation Use the TouchPad to access the menu or respond to messages. Menu commands are available using keys to scroll and select items or via numeric shortcuts. To scroll to select a menu command: • Press to access the menu. • Press • Press Enter to select the current Menu item. arrow keys to scroll through menus. To select a menu command using a shortcut: • Press to access the menu. • Use the numeric keypad to enter the shortcut numbers. For example, to view messages, press -1-1. To exit the menu: • Press to return to the Main Screen, or • Press to return to the previous menu (move up one level). To change a menu item: • Press Enter to select the Menu item or press • The screen displays the current value, such as an IP address or date. • Use the numeric keypad to enter a new value. • or to move the cursor, then press To edit specific values, press Use the numeric keypad to enter new values. • Press Enter. • When prompted, press • Press Updated: May 2012 and the numeric code. to confirm the new value or press to delete. to cancel. to exit the menu and return to the Main Screen. Relevant S/W Ver: 5.2.9 and above ChronoTrack Systems, Inc. 4.3 MiniTrack User Manual Using the MiniTrack Controller Menu Commands The following table provides a summary of menu commands and a quick-reference for menu codes. Shortcut Command 1–1 1–2 1–2–1 1–2–2 1–2–3 2–1 2–2 2–3 3–1 3-1-1 3-1-2 3–2 3–2–1 3–2–2 3–3 3–3–1 3–3–2 3–3–3 3–4 3–4–1 3–4–2 Messages View/Acknldg Markers Marker Wave End Next Point Server Connect Address Disconnect Tools Zero Counts This Ctrl All Ctrls File Copy Current All Files Mode Low Power Immediate Chanel set Maintenance Dry Reader Cmd 4–1 4–2 4-3 4–4 4–4–1 4–4–2 5–1 6–1 6–2 6–3 7–1 7–2 7–3 7–3–1 7–3–2 7–3–3 7–3–4 7–3–5 7–4 Time Manual Sync Brdcst Sync Server Sync ChronoSync Send Recv Audio Beep On/Off Network Cfg Ctrlr IP Ctrlr Netmsk Ctrlr Gateway Status Temperature MAC Address Versions Pwrbrd Rdr S/W Rdr H/W Hdwr Ver Serial # Copyright Updated: May 2012 Description View/acknowledge alert messages Add a marker to file to divide tag times into different groups General marker Create divider for wave starts Change use of MiniTrack to a different point Connect to the ChronoTrack Server Set the IP address for the ChronoTrack Server Disconnect from the ChronoTrack Server Clear the counts that are displayed on the Main Screen … …on just THIS controller …on ALL networked controllers Copy controller data to a USB device Copy the current tag observation files to a USB drive Copy all the tag observation files to a USB drive Change mode or settings for tag reporting Turn down antenna power Report tag read immediately (supports announcer displays) Set the frequency the antennas use (applies to select countries only) Non-race options Turn on fan to aid in drying out case. Do not use during a race! (Future) Send commands to reader (use only with direction from ChronoTrack) Manually enter and set controller’s date/time Broadcast this controller’s time to all other networked controllers (Future) Pull time from the server (Future) Use ChronoSync USB device to set/read time Send controller’s time to ChronoSync Read time from ChronoSync and set time Turn tag beep on and off Set controller’s IP address Set controller’s Netmask Set controller’s Gateway Display reader and PowerBoard temperatures Display the MAC Address of the reader Display version information for ChronoTrack staff View PowerBoard firmware version View reader application version View reader firmware version View version of PowerBoard hardware View controller serial number View copyright information Relevant S/W Ver: 5.2.9 and above ChronoTrack Systems, Inc. MiniTrack User Manual Using the MiniTrack Controller 4.3.1 Creating a Gun Start Timestamp To set the Gun Start during an event, press the Gun Start button on the MiniTrack controller side panel. 4.3.2 Viewing Messages The Messages screen is used to view and acknowledge system alerts, and to view gun and marker timestamps. If multiple messages are available, the most recent message will be shown at the top of the list. To view messages: -1-1 or press 1. Press 2. Accessing this screen silences the alert bell. 3. Use 4. Press 4.3.2.1 and and scroll to select 1. Messages → 1.1 View. to scroll through messages. to return to the Main Screen. Viewing Current Event / Point Information The first two messages in the queue will be the Event and Point names for the current session. This allows the user to know the exact Event/Point that their data will be in if they connect it to the server or use CCSLite and SimpleClient. Additionally, if they use the Event / Point Rename functionality, this allows the user to determine how the controller is currently configured. 4.3.3 Setting File Markers Creating file markers helps you organize the data. When you set a marker, data from that point on is collected in a different session. To set a marker timestamp: -1-2 or press 1. Press 2. Select a marker type: and scroll to select 1.2 Markers. • 1.2.1 Marker adds a general marker to differentiate data. • 1.2.2 Wave end adds a marker with the label “Wave End” for improved organization. • 1.2.3 Next Point adds a marker with the label “Next Point” for improved organization. Marker timestamps are displayed on the menu/message LCD, and can also be viewed from the Messages menu. 4.3.4 Server Configuration In order to transfer controller data live to a networked laptop or the ChronoTack CCS Server, a network connection must be established with a server. To set the server address: -2-2 or press 1. Press and scroll to select 2. Server → 2.2 Address. 2. Use the numeric keypad to enter the IP address you wish to use as the server, then press Enter. 3. A message appears to confirm the IP address change. Press to confirm or press to cancel. After setting the server address, you must establish the network connection. To connect to the server: -2-1 or press 1. Press 2. While a connection is being attempted, the Connected LED blinks. Updated: May 2012 and scroll to select 2. Server → 2.1 Connect. Relevant S/W Ver: 5.2.9 and above 10 ChronoTrack Systems, Inc. 3. MiniTrack User Manual Using the MiniTrack Controller When a connection is established, the Connected LED turns on. To disconnect from the server: -2-3 or press and scroll to select 2. Server → 2.3 Connect. 1. Press 2. The Connected LED turns off and the connection is closed. The controller and server monitor the connection. If it is dropped, the controller will automatically attempt to reconnect. After a few times attempting without success, the controller will create an error message and light the Alert LEDs to notify the user of the problem. It will continue to attempt to connect to the server but there may be problems that require the user to intervene (i.e. CradlePoint unplugged, cellular signal not found, server inaccessible or shutdown). 4.3.5 Tools 4.3.5.1 Zeroing Tag Counts The Zero Counts command allows you to reset the unique and total tag count numbers displayed on the Main Screen of the controller. Zero Counts also ignores all prior data in the current session. You may want to zero tag counts if you are using the same timing line for a start and finish. After all participants have crossed the start line, create a marker and then zero the count by doing the following: 1. Press -3-1 or press 2. Press to confirm the action. 4.3.5.2 and scroll to select 3. Tools → 3.1 Zero counts. Copying Files to USB When a controller is powered ON, it creates and works on one data file (AKA the current file) until the box is powered OFF. If a controller is powered ON and sees no tags during that session, an empty file is created. You can copy the data files from a controller to a USB device to load the data into SimpleClient. There are two options: Current and All. The Current option can be to copy the file with data currently being saved to it. This file can be copied at any time throughout the race. It can also be copied multiple times during a race as more people finish. The All option can be used to retrieve all of the data the controller has collected over the last 2 weeks, including the current file. To copy the Current file to a USB device: 1. Insert a USB device into one of the USB slots on the controller. Wait for it to beep. 2. Press 3. Wait until the screen says “Copying-Done”. Make sure the USB drive’s activity indicator stops flashing and then pull the drive out of the controller. -3-2-1 or press and scroll to select 3. Tools → 3.2 File Copy → 3.2.1 Current. To copy the All files to a USB device: 1. Insert a USB device into one of the USB slots on the controller. Wait for it to beep. 2. Press 3. Wait until the screen says “Copying-Done”. Make sure the USB drive’s activity indicator stops flashing and then pull the drive out of the controller. Updated: May 2012 -3-2-2 or press and scroll to select 3. Tools → 3.2 File Copy → 3.2.2 All Files. Relevant S/W Ver: 5.2.9 and above 11 ChronoTrack Systems, Inc. MiniTrack User Manual Using the MiniTrack Controller While the USB 2.0 Standard is backward-compatible with 1.0, not all USB devices meet the USB 2.0 standards. We recommend testing your flash drive before an event. We also recommend using thumb drives less than 2GB; larger drives take longer to initialize and sometimes appear to have caused the system to lock up when it has not. 4.3.6 Low Power The Low Power feature is not used for outdoor races but may apply to indoor events such as stairwells. To turn down antenna power: 1. Press -3-3-1 or press 2. Press or 3. Press Enter. 4. When prompted, press 4.3.6.1 and scroll to select 3. Tools → 3.3 Mode → 3.3.1 Low Power. to adjust by 5% or to adjust by 1%. to confirm the new value or press to cancel. Immediate Mode The Immediate mode reports the tag reads immediately, allowing an announcer to view live results. Times reported are not the official time. To enable the Immediate mode: -3-3-2 or press and scroll to select 3. Tools → 3.3 Mode → 3.3.2 Immediate. 1. Press 2. To deactivate the Immediate mode, select 3.3.2 Immediate again. Select the Immediate mode to work with live results reporting for an announcer line. In this mode, the controller reports both immediate and official tag read times. To create an announcer line, you must also enable Immediate mode in SimpleClient. See Creating and Using an Announcer Line for more information. 4.3.6.2 Chanel Set SELECT COUNTRY MODELS ONLY: Set the frequency of the controller. You must ensure adjacent or primary/ backup controllers do not share the same frequency. 3-3-3 or press 1. Press 2. Use 3. Press Enter. 4. Press or and scroll to select 3. Tools → 3.3 Mode → 3.3.3 Chanel Set. buttons to select A, B, C or D. to confirm the new value or press to cancel. 4.3.7 Dry Mode Activating the dry mode turns on a fan to pump air through the controller box. To start the dry mode: -3-4-1 or press 1. Press and scroll to select 3. Tools → 3.4 Maintenance → 3.4.1 Dry. 2. The fan turns on. To deactivate the fan, select 3.4.1 Dry again. Do not use Dry Mode during a race! Updated: May 2012 Relevant S/W Ver: 5.2.9 and above 12 ChronoTrack Systems, Inc. 4.3.7.1 MiniTrack User Manual Using the MiniTrack Controller Sending Reader Commands The Reader Cmd menu item enables you to send commands directly to the reader. Use only with direction from ChronoTrack staff. Do not attempt to use this feature without advanced knowledge of these commands. If controllers are networked, these commands are sent to all controllers and subsequent readers on the network. To send a command to the reader: -3-4-2 or press 1. Press and scroll to 3. Tools → 3.4 Maintenance → 3.4.2 Reader Cmd). 2. In the menu, select the command to send. 3. Press Enter. 4.3.8 Setting the Time and Date The Time menu gives you the option to manually set the time and date on a single controller, synchronize the controller’s time to the server, or use the ChronoSync USB device to set or read the time. 4.3.8.1 Setting the Date and Time on a Controller To manually set the date and time on a controller and any others networked to it: -4-1 or press 1. Press 2. Use the numeric keypad to enter the date in [yyyy]/[mm]/[dd]. The controller inserts slashes automatically. 3. Press Enter to confirm the date or start typing a new date to change it. 4. When prompted, enter the correct time in [hh]:[mm]:[ss] format. The controller inserts the colons automatically. 5. Press Enter to accept the time. 6. Press and scroll to select 4. Time → 4.1 Manual Sync. to confirm message. The alert indicator LEDs light up to indicate the time has been set. 4.3.8.2 Broadcast Sync To push this controller’s time to all other controllers on the same network: -4-2 or press 1. Press and scroll to select 4. Time → 4.2 Brdcst Sync. 2. All controllers on the network will receive the new time. The alert indicator LEDs light up to indicate the time has been set. 4.3.8.3 Server Sync To synchronize the time with the server, you must first establish a connection with the server. To synchronize the time with the server: -4-3 or press 1. Press 2. Press Enter to synchronize the time. Updated: May 2012 and scroll to select 4. Time → 4.3 Server Sync. Relevant S/W Ver: 5.2.9 and above 13 ChronoTrack Systems, Inc. MiniTrack User Manual Using the MiniTrack Controller The Alert indicator LEDs blink while the server is being contacted. They change to ON to indicate the time has been set. 4.3.8.4 ChronoSync This USB device not yet implemented 4.3.9 Audio Menu You can activate or deactivate the tag beep, which sounds when a tag is in the field. Error beeps cannot be disabled. To turn the tag beep on or off: 1. Press 2. Press 5-1 or press 5-1 or press and scroll to select 5. Audio → 5.1 Beep:On. and scroll to select 5. Audio → 5.1 Beep:Off. 4.3.10 Network Configuration Do not make changed here unless directed. Network configuration options are available to reconfigure the IP address, netmask, and gateway for LAN and Wi-Fi networks. To change network settings: -6 or press 1. Press and scroll to select 6. Network Cfg. 2. Select the network configuration option from the menu: • 6.1 Ctrlr IP allows you to view or change the controller’s IP address • 6.2 Ctrlr Netmsk allows you to view or change the controller’s Netmask • 6.3 Ctrlr Gatewy allows you to view or change the controller’s gateway 3. Use the numeric keypad to enter the new value. Press Enter. 4. When prompted, press to confirm the new value or press to cancel. 4.3.11 Temperature The Temperature menu indicates the reader and PowerBoard temperatures in Celsius. For safe operation, the reader temperature should be below 70 and the PowerBoard temperature should be below 70. To view the temperature of controller components: 7-1 or press and scroll to 7. Status → 7.1 Temperature. 1. Press 2. If the temperature is above the safe operating level, the controller fan automatically cycles. 4.3.12 MAC Address This menu option reports the MAC Address of the reader in the Controller. It displays all 12 digits of the MAC but instead of the typical 6 tupples separated with colons; it displays 6 digits, a colon separator, and the last 6 digits. This is due to the space constraints of the screen. To view the MAC Address: 1. Press Updated: May 2012 7-2 or press and scroll to 7. Status → 7.2 MAC Address. Relevant S/W Ver: 5.2.9 and above 14 ChronoTrack Systems, Inc. MiniTrack User Manual Using the MiniTrack Controller 4.3.13 Versions These menu options report version information for ChronoTrack staff. You may need to access this menu to support a troubleshooting call. To look up copyright and version information: 7-3 or press 1. Press and scroll to 7. Status → 7.3 Versions. 2. The Versions menu displays the following: • 7.3.1 PwrBrd PowerBoard firmware version • 7.3.2 Reader S/W Reader application version • 7.3.3 Reader H/W Reader firmware version. • 7.3.4 Hdwr Ver Version of the PowerBoard hardware • 7.3.5 Serial Num Serial number of the controller 4.3.14 Copyright To display the copyright of the controller: 1. 4.4 7-4 or press Press and scroll to 7. Status → 7.4 Copyright. Pre-configuring the MiniTrack Starting with v5.1.3 of the MiniTrack software, the user can configure some of the settings on a controller by supplying an INI file on a USB drive. This drive must be inserted before the controller is powered on in order for the new name to take effect. Once the INI file is processed, the controller will have the specified settings. Any text editor, such as Windows Notepad, can be used to edit the file. The file format is as follows: {ctrlr}.{field}={name} The fields are as follows: • ctrlr = the serial number of the controller to be set; ‘ALL’ can be used to set every controller • field = the name of the setting to change • value = the value to use for the specified field 4.4.1 Fields There are shared fields between the two types of controllers and the Event Screen of the ChronoView website: Event view Mini Pro Field Description Limit Example EVENT Event name CHICAGOHALF POINT Point name CONTROLLERS READERS 1-16 GATORS 1-64 16 SERVER Number of controllers at this point Number of readers at this point Number of gators at this point IP address of the 16 char length; A-Z and 0-9 16 char length; A-Z and 0-9 1-8 Standard IP 50.17.233.218 Updated: May 2012 Relevant S/W Ver: 5.2.9 and above Start 15 ChronoTrack Systems, Inc. MiniTrack User Manual Event view Description Limit Chronotrack server Power the WiFi on or off Power the GPRS on or off IP address of the network gateway Identifies controller distance from start Contact name of timer at point (name can contain spaces) Phone number of timer at point Expected first runner time at point Expected last runner time at point Notes associated with point address ON/OFF ON/OFF Standard IP address All decimal numbers A-Z, a-z, 0-9 Mini Pro Field WIFIPOWER GPRSPOWER GATEWAY DISTANCE CONTACT PHONE EFIRST ELAST NOTE Using the MiniTrack Controller Example ON OFF 172.20.23.1 3.3 Bob Square Phone # or Skype user Free form 812.759.7877 0:25 Free form 1:20 Free form Watch for manhole cover in WB lane 4.4.2 Clearing Values There are three methods to use if the event or point name needs to be returned to its default value: 1. INI file with no lines in it 2. INI file with a line for the controller to clear but nothing after the equal sign 10043.EVENT= 3. INI file with a line for the controller to clear and the key word 'default' as the name 10043.EVENT=default Values cannot be cleared on the Pro Series controllers at this time. 4.4.3 Comments Comment are allowed in the file— just start the line with a hash mark (#). Blank lines are also allowed. 4.4.4 File and Directory Names The INI file should be placed on a USB drive in the 'New' directory in the root directory. For example, if your USB drive is at F:, the full path would be F:\New\CtrlCfg.ini 4.4.5 Example The following is a sample file: This file lists all controllers used for the Pumpkin Run 2011. Note that it also clears controllers that were not used in the race (10004 & 2382). The start is handled by 1 Pro controller, the 5K is handled by 1 Mini, and the finish is handled by 2 Pros. # 'ALL' can be used to set a value for every controller. This first group # of configs will demonstrate. # ************************************************************************ # Set every controller's event to 'PUMPKIN2011' ALL.EVENT= PUMPKIN2011 # Set every controller's WiFi off Updated: May 2012 Relevant S/W Ver: 5.2.9 and above 16 ChronoTrack Systems, Inc. MiniTrack User Manual Using the MiniTrack Controller ALL.WIFIPOWER=OFF # Set every controller to auto connect when done booting ALL.SERVER-AUTO-CONNECT TRUE # Set every controller's server setting ALL.SERVER=50.17.233.218 # This group sets up the POINT value for each controller. # ******************************************************* 2223.POINT =START 10305.POINT =5K 2385.POINT = FINISH 2102.POINT = FINISH # Clear the unused controllers. # ***************************** 10004.EVENT= 10004.POINT= 10006.EVENT= 10006.POINT= # Start Line # ********** # Only one 800 controller at the start. 2223.CONTROLLERS = 1 # An 800 has 2 readers. 2223.READERS = 2 # Will use 8 gators at this line. 2223.GATORS = 8 # Turn on the Cell Modem. 2223.GPRSPOWER = ON # Clear the Gateway. 2223.GATEWAY # 5K Line # ******* # A Mini needs to have a gateway defined in order to use the CradlePoint. 10305.GATEWAY=172.20.23.1 # Finish Line # *********** # Two 800 controllers at the finish. 2385.CONTROLLERS = 2 # Each 800 has 2 readers. 2385.READERS = 4 # Will use 14 gators at this line. 2385.GATORS = 14 # Turn off the Cell Modem -- using LAN cable. 2385.GPRSPOWER = OFF # Clear the Gateway. 2385.GATEWAY 2102.CONTROLLERS 2102.READERS 2102.GATORS 2102.GPRSPOWER 2102.GATEWAY 4.5 14 OFF Collecting Select Times If you would like to use the MiniTrack to collect select times, you can purchase and connect the wireless number keypad (see System Specifications). Collecting select times allows timers to cross-reference select times with times from the controller and identify participants who were not automatically tracked due to tag damage or loss. These times show up right in the scoring software simplifying the lookup task. Updated: May 2012 Relevant S/W Ver: 5.2.9 and above 17 ChronoTrack Systems, Inc. MiniTrack User Manual Using the MiniTrack Controller NOTE: You must use SimpleClient v0.4.7 or later to view the results—previous versions do not provide support for Select Time data stream. 4.5.1 Using the Keyboard Key . (period) 0-9 Enter Back Clear Action Test key, the controller beeps to confirm the device connection Numeric entry, limited to 5-digit bib identifiers Primer for a gun start; type equal sign, then type enter when the gun goes off Submits entry, assigning the time stamp to either the bib number or the gun start Erases the last key entered; also works for the gun start primer (=) Clears the complete entry since the last entry was submitted (Enter key) To use the wireless keyboard to manually collect times: 1. Insert the USB receiver for the wireless keyboard into an available port on the MiniTrack controller. The controller will beep when the USB is inserted. 2. Turn on the numeric keypad, using the power switch on the back of the device. 3. Press ‘.’ (period) to test the connection. You should hear an audible beep. 4. Press the equal sign (=) to prime for a gun start, then press Enter when the gun sounds. 5. Use the numeric keys (0-9) to enter bib numbers. Press Enter to submit each bib number. The bib can be 5 digits maximum. 6. It is a good idea to test the wireless connection every so often by hitting the period key. This makes sure you still have a connection to the Mini and is due to the limited range of the wireless system. If the Mini does not beep, the fix is to unplug and plug in the USB receiver. Updated: May 2012 Relevant S/W Ver: 5.2.9 and above 18 ChronoTrack Systems, Inc. MiniTrack User Manual Using CCSLite 5. Using CCSLite CCSLite is an application that acts as a bridge between wired (LAN) and Wi-Fi network connections on the controller and SimpleClient, an application for retrieving and manipulating controller data. CCSLite must be running when establishing a wired or Wi-Fi network. 5.1 Configuration of CCSLite To configure CCSLite, complete the following steps: 1. Start the CCSLite application on your computer. 2. Make sure Windows is not blocking TCP port 61610. When CCSLite is started for the first time, you are prompted to choose whether or not the program is allowed to listen for incoming connections. If not, this setting can be altered manually—see Adding a Firewall Exception for CCSLite. 3. From the menu, click Action > Storage Directory, and set the path where CCSLite will store controller data. 4. From the menu, click Action > SimpleClient Path, and select the SimpleClient executable to use when opening data streams from the CCSLite controller grid. 5. Close CCSLite to store the settings and apply them for the next start-up of CCSLite. 5.2 Establishing Controller Connections To establish controller connections with CCSLite: 1. Start the CCSLite application on your computer. 2. On the controller, make a server connection to CCSLite, using the local IP address of your computer as the server address. 3. If the controller is connected to CCSLite, you will find a new row in CCSLite's connection grid displayed on the main screen. 4. Double-click the entry of the controller in the CCSLite grid. This will open an instance of SimpleClient showing you the available sessions from that controller's active file. Updated: May 2012 Relevant S/W Ver: 5.2.9 and above 19 ChronoTrack Systems, Inc. 5.3 MiniTrack User Manual Using CCSLite CCSLite Raw Mode If controllers are connected to the local network, CCSLite will listen for tag observations straight from the readers. This is called raw mode. This information does not contain markers (event names, point names, gun markers, and manual markers) and controller software is completely ignored. However, a backup of all raw observation data on the local network is available for use. The raw stream also contains the information gathered from a “raw reader dump” in case of a controller lock-up. Raw reader dumps are the final option in data recovery and should only be used if all other actions have failed. To isolate data from the different controllers on the network, a virtual point configuration file (with .rmg extension) can be used (see Creating Virtual Points). 5.4 Adding a Firewall Exception for CCSLite rd If you use a 3 -party firewall, check the supplied documentation. Otherwise, complete the following steps to add a firewall exception to Windows XP: 1. Start the security center: From the Windows Start menu, open the Control Panel and select the Security Center menu item. 2. From the Security Center, open the Windows Firewall settings. 3. On the General tab, make sure the Don’t allow exceptions box is unchecked if the firewall is activated (preferred). 4. On the Exceptions tab, check to see if the list box of allowed exceptions shows CCSLite. If not, unlock the program by using either the Add Program button or the Add Port button. NOTE: If you choose to add the program to the exception list, this port is only unlocked for the CCSLite program started from the specified path. You will block it again if you change the path of CCSLite. Instead, add TCP port 61610 to ensure that any program attaching to that port can be reached, regardless of its program path. Also, there may be other applications running with firewalls set (specifically programs like anti-virus, spyware protection, and ad blockers); either disable these programs, or add exceptions for CSSLite. Updated: May 2012 Relevant S/W Ver: 5.2.9 and above 20 ChronoTrack Systems, Inc. MiniTrack User Manual Using SimpleClient 6. Using SimpleClient SimpleClient is an application used to retrieve and manipulate controller data. Data from events, including real-time stats, can be filtered and streamed from SimpleClient to your computer or directly into your race scoring software. 6.1 SimpleClient Operation Modes There are two modes of operation when working with SimpleClient: • Local network mode • Internet server mode 6.1.1 Local Network Mode Local network mode is used when connecting controllers through the wired (LAN) or wireless network (802.11). To load controller files in this mode, you must either use CCSLite as a bridging application (see Using CCSLite), or load them from a USB drive. To load from USB, use one of the following methods: • From the SimpleClient main menu, click File > Load Controller File. • Drag and drop a .mrk or .csv file onto the ChronoTrack logo on the SimpleClient main screen. 6.1.2 Internet Server Mode Controllers can send their data to the ChronoTrack CCS servers located on the Internet by using either the built-in cellular modem or a connected router (wired LAN or wireless 802.11). The following servers are available for North American users: • Main server: east01-us.chronotrack.com (50.17.233.218) • Backup server: east02-us.chronotrack.com (50.17.233.220) The CCS Server will show sessions from all controllers and any uploaded events. This data is stored for approximately three weeks. To obtain data from the CCS Server online and use it on your local computer, establish a connection with the CCS Server using your ChronoTrack user account. See Connecting to the Server and Retrieving Data for more information. 6.2 Connecting to the Server and Retrieving Data You can send data from a controller into SimpleClient by connecting to the CCS Server. To connect to the CCS Server, complete the following procedure: 1. Establish a network connection on the controller. See Establishing Network Connections. 2. Start the SimpleClient application on your computer. 3. If you want to be connected directly to your scoring software, see Establishing a Direct Socket Connection with Scoring Software. 4. From the main menu, click CCS Server > Connect. 5. A connection box is displayed. Make sure that the box contains the following information: 6. Hostname: 50.17.233.218 or east01-us.chronotrack.com TCP Port: 61612 Your log-in username Your password Click Connect. Updated: May 2012 Relevant S/W Ver: 5.2.9 and above 21 ChronoTrack Systems, Inc. MiniTrack User Manual Using SimpleClient The Select Device Session screen is displayed and you are now connected to the server with all of your events. 7. Filter to display only your current event by unchecking All events. 8. Use the drop-down list to select the event from which you want to retrieve data. 9. Click on the segment to load, then click Select at the bottom of the screen. The SimpleClient main screen is displayed. You can now either start streaming the data and/or save the data for import into your software: To start the data stream onto your computer, click Play. If you have a direct connection with your scoring software, you will see the times in your software. To save the data, click Play. From the main menu, click File > Save As. 10. Repeat these steps to connect to other checkpoints. Alternately, open a new session of SimpleClient to run multiple streams at the same time. 6.3 Streaming Data After selecting a file segment to stream onto your computer (see Connecting to the Server and Retrieving Data), use the following buttons on the SimpleClient interface to start, stop, and rewind data: • Play: Starts the data stream into a buffer on your computer. • Stop: Stops the data stream. To pick up where you left off, press Play. • Rewind: Starts the data stream over from the beginning. Updated: May 2012 Relevant S/W Ver: 5.2.9 and above 22 ChronoTrack Systems, Inc. MiniTrack User Manual Using SimpleClient As the data plays, there are two red numbers above the buttons. The first red number indicates the size of the save buffer (see Saving SimpleClient Data). The second indicates the size of the invalidated tags buffer (see Tag Invalidation). The middle section of the screen displays the data for each tag as it plays. 6.4 Tag Invalidation Tags can be invalidated in order to prevent them from appearing in your race scoring software. There are three features that can be used to specify which tags should be invalidated: • Activated tag range filtering • Ignore same tag for X seconds • Activated invalidate negative times To inspect tags that have been invalidated, from the SimpleClient main menu, select View > Invalidated Tags. The screen shows all invalidated tags listed by order of arrival. The reason for invalidation of each tag is also shown. If a tag has been invalidated in error, it can be revalidated: 1. Select the tag entries on the grid that should be revalidated. 2. Right-click and select Validate Selected. The revalidated tags will be removed from the grid and the observations will be put at the end of the save buffer, ready to be streamed to the race scoring software or saved to text file. 6.5 File Formats SimpleClient lets you export data and specify how the files are formatted (separators, line terminators, etc.). This is useful when you need to send data to a third-party application that requires a specific file format. To specify file formats, from the main menu, click File > File Format. See File Format Specifications in the Appendix for information about available formats and syntax. 6.6 Saving SimpleClient Data You can manually save the current feed/buffer, or configure SimpleClient to save files automatically: • To save the current buffer in SimpleClient (as indicated by the first red number on the main screen), from the main menu, click File > Save File. • To automatically save files, click File > Auto Save and set the path where the files should be saved. You can then configure your scoring software to retrieve data from that path. If you want each session that you open for a different point to be automatically saved using the point designation as the file name, click File > Auto Save and check Single Point/File. When this option is not checked, each stream is saved to its event designation (so you can have multiple points in a file belonging to the same event) and uses the event designation in the file name. When saving files, both manually and with Auto Save, the output is sent to either a text file or, if established, to a direct socket connection, for streaming into your scoring software. A direct sockect connection is the preferred solution with RunScore scoring software. Updated: May 2012 Relevant S/W Ver: 5.2.9 and above 23 ChronoTrack Systems, Inc. 6.7 MiniTrack User Manual Using SimpleClient Filtering Data Filters can be applied to organize your data. You can filter out bib numbers from previous events or filter by various segments such as leagues. Tag filters can be created online and applied in SimpleClient so that only tag data within specified bib ranges, event codes, and/or timer codes is streamed. The Select Session File screen in SimpleClient is used to activate tag range filters that you create online. To filter the data shown in SimpleClient, complete the following procedure: 1. On the Select Session screen, select the point containing the data you want to filter. 2. Select the Activate Tag Range Filtering option. 3. The Tag Ranges for Event drop-down menu contains a list of tag ranges that you have created pre-event. Select the tag ranges for your event. 4. The columns in the middle of the screen display the filtering selections of timer and event codes and names, and minimum and maximum bib numbers. D-Tags are assigned a timer and event code when they are printed and encoded. 6.7.1 Creating Tag Ranges for an Event To create tag ranges for an event, complete the following procedure: 1. Prior to the event, log in to the ChronoTrack StreamManager at https://secure.chronotrack.com with your valid ChronoTrack user account. After logging in, a Welcome page with your name is displayed. 2. Click the Manage Events heading. 3. Click Add an Event. 4. Enter the information about your event. 5. Click Submit. The page now shows the tag range you created. 6. To save the tag ranges locally to your computer, from the main menu, click CCS Server > Update Local TagRange DB. 6.8 Creating Virtual Points Some events, like triathlons, will utilize multiple points at the same location (run in, bike out). For these types of events, it is possible either to use multiple controllers in normal mode, or to split up the points based on individual Gators or combinations of Gators from a single controller. To split the point names, you will need to relocate point information on your readers and Gators by creating and loading a virtual point file in Simple Client. This file specifies which MAC addresses should be assigned to which reader and ports. The virtual point file must be an ASCII file with an RMG file extension. The text must be semicolon-delimited with each new point on a separate row. The syntax for each row is: [ReaderMACAddress];[FirstGatorID];[LastGatorID];[NameOfNewPoint] Valid Gator IDs are 1, 2, 4, and 8. Below is an example of a virtual point file: 003487;1;1;GATOR1 003487;2;2;GATOR2 003487;4;4;GATOR3 003487;8;8;GATOR4 This example relocates each Gator to a new point name. The most common setup would be to separate both readers and can be done like this: 003487;1;8;READER1 0034AF;1;8;READER2 Updated: May 2012 Relevant S/W Ver: 5.2.9 and above 24 ChronoTrack Systems, Inc. MiniTrack User Manual Using SimpleClient After creating the virtual point file, load it into SimpleClient with the following steps: 1. From the SimpleClient main menu, click Settings > Relocate Point Info on Reader/Gator. 2. Select Virtual Points. 3. Click Configure. The file is now loaded and will be included in the Select Session screen, labeled “Virtual Points”. 6.9 Creating and Using an Announcer Line Announcers can view live data about participants during an event with an announcer line. To create, load, and view an Announcer Line, do the following: 1. Create a bib file. A bib file is an ASCII semicolon-delimited file with field headers. The field headers are displayed as column headers in the announcer line. The first field header must be the bib number, but you can add as many other fields as you like. Below is an example of the first few lines of a bib file: BIB;FIRSTNAME;LASTNAME;AGE;SEX;CITY;DIVCODE 25;Scott;Abrams;51;M;LA PINE;G 26;Julio A;Aguirre;62;M;HIGHLAND PARK;I 27;Claus G.;Ahrens;25;M;JERSEY CITY;C 2. From the SimpleClient main menu, click File > Load Bib File and select the file you just created. This loads the file into SimpleClient. 3. In order to view live data streaming into the Announcer Line, make sure there is a network connection with the controller, then put the controller into Immediate mode (see Immediate Mode). 4. Enable Immediate mode in SimpleClient by selecting it from the Tag Mode drop-down list on the Select Session screen. NOTE: When the controller and SimpleClient are in Immediate mode, tags are only reported once despite the number of reads. 5. From the SimpleClient main menu, click View > Announcer Display. 6. On the SimpleClient main screen, click the Play button. You can resize the Announcer Display window to zoom text by dragging the edges. The Flush Queue option clears the grid and can be used to help announcers keep up with participants if the streaming data is coming in too quickly (like runners crossing a finish line). Other options are available to set the scroll speed in seconds, change number of rows, colors, and more. To hide tags that do not contain participant data, from the Announcer Display window, click View > Hide Unknown Tags. 6.10 Loading Controller Files After copying a file from a controller to a USB device, load it into SimpleClient by doing one of the following: • From the SimpleClient main menu, click File > Load Controller File, then select the file to load. • Drag the file onto the SimpleClient main screen. When you load a controller file, the Select Session screen displays the event and point names. If markers exist in the file, any tags after a marker are listed on another row. To stream the data, select the event and point and click Select, then click the Play button on the SimpleClient main screen. Updated: May 2012 Relevant S/W Ver: 5.2.9 and above 25 ChronoTrack Systems, Inc. MiniTrack User Manual Using SimpleClient To connect directly to your scoring software, follow the instructions under Establishing a Direct Socket Connection with Scoring Software. Alternately, you can save the data to a file that you can import into your scoring software by clicking File > Save File from the main menu. Repeat this process to import, play, and save other files that you have copied from the controller. 6.11 Establishing a Direct Socket Connection with Scoring Software You can connect SimpleClient to your scoring software with a direct socket connection. This enables data to stream directly into your scoring software when you start a data stream in SimpleClient. To establish a direct socket connection, complete the following procedure: 1. Open your scoring software (for example, RunScore, Race Director, or your own software). 2. Initialize your software to allow connections from SimpleClient on port 61611. 3. Open SimpleClient. 4. On the main menu, click Direct Socket Out, and make sure Enabled and Auto Reconnect are checked. 5. Click Direct Socket Out > Connect. A connection window is displayed showing the hostname as “local host” and the TCP port as “61611”. 6. Click Connect on the connection window. Connecting opens the socket so that when you play data in SimpleClient, the data is also streamed directly into the scoring application. 6.12 Setting Time Intervals for Pass Counts and Same Tag Observations You can set the time interval for pass counts so that if the same tag is read twice within a specified time, it is not marked as a second lap. For example, if it takes at least five minutes to complete one lap, you could set the time interval to four minutes so that any tags read twice within four minutes are not counted. To set the time interval from the SimpleClient main menu, click Settings > Time Interval for Pass Count. You can also specify that the same tag should be ignored for a specified number of seconds. This is useful to prevent the same tag from being reported twice when you have primary and backup lines. To set this option, from the main menu, click Settings > Ignore Same Tag for … Seconds. Ignored tags are placed in the invalidated tags list (see Tag Invalidation). 6.13 Creating Time Shifts If the controller time was not accurate for your needs when it was collecting data, you can adjust the time using SimpleClient. To create a time shift, use the Time Shift set of options on the Select Session screen: • Disabled: No time shift adjustments. • UTC to local timezone: Shifts the time to match your computer’s local time. • Manual: Enables you to enter a specific time. • 00:00 Start: Used to set the date and time if the time at Gun Start was a zero time. 6.13.1 Disabled By default, tag observations are not time-shifted. Since most race scoring software cannot handle dates and the ChronoTrack controller holds both date and time, the controller timing information needs to be converted. To allow timing events with a duration over 24 hours, the normal output mode is in a special 24h+ format. To convert the controller time to 24h+ format, SimpleClient introduces a concept of base dates. When a session is selected and the stream is started, the first tag observation or gun marker (whichever comes first) is inspected. The date found in this tag observation or gun marker is now set as the base date. Each consecutive observation or marker is inspected for its date and compared to the base date. If the date is the same, a normal time output can be expected, ranging Updated: May 2012 Relevant S/W Ver: 5.2.9 and above 26 ChronoTrack Systems, Inc. MiniTrack User Manual Using SimpleClient between 0:00:00.00 and 23:59:59.99. If the date found is later than the base date, the difference in days is multiplied by 24 and added to the hours section of the time of day. If the date found is earlier than the base date, the output will contain a negative time showing the difference between the observed time and midnight at the base date. If you do not want to output negative times, you can disable the output of negative times from the SimpleClient Settings menu. 6.13.2 UTC to Local Timezone Use this mode when you synchronize the controllers by GPS to the UTC timezone. In this mode, the difference between UTC timezone and your computer's timezone setting will be used for a time shift, resulting in timing output converted to local time of day. After times are shifted, SimpleClient will continue to use its base date logic. 6.13.3 Manual If you find a controller to be off by a specific amount of time, you can use the manual option to adjust the controller's misaligned timing. A positive offset will increase the times, while a negative offset will decrease times. After times are shifted, SimpleClient will continue to use its base date logic. 6.13.4 00:00 Start This option can be used for multiple timing issues and is very powerful. By setting the date and time part of this option, you pinpoint an exact moment in time on which the timing output of SimpleClient will be equal to 0:00:00.00. The difference between a tag observation’s date and time and this zero point will be the output to your race scoring software. By only setting the date and keeping the time to 0:00:00, you can set the base date manually, overriding SimpleClient's automated base date discovery in case it gives you timing errors. By also setting the time, you can actually convert SimpleClient's output to race time instead of time of day. If you enter both date and time equal to the gun time, you will get this behavior. If you have used a gun marker on the controller and its timing information is displayed on SimpleClient's session form, you can drag the gun marker to the 00:00 Start Time Shift option to automatically fill it in. 6.14 Renaming Events/Points Events and points can be renamed in SimpleClient. On the Select Session screen, type the new names in the Rename Event and Rename Point text boxes. When you change an event or point name in SimpleClient, the name is relabeled in the text file output or direct socket protocol. 6.15 More SimpleClient Functions More SimpleClient functions are described below. • To view gun times, from the main menu, click View > Gun Times. This displays information about each gun start set in the file. • To view invalidated tags, from the main menu, click View > Invalidated Tags. • If you have already loaded a session from a controller file, you can go back to the same CSV file and select another session from it to load. To do this from the main menu, click File > Show Available Sessions. This option is only available when working in local mode (as opposed to server mode, when you are connected to the CCS Server). • If you are working on a session, you can close local mode and switch to a CCS Server stream without closing Simple Client. To do this from the main menu, click File > Close Local mode. Updated: May 2012 Relevant S/W Ver: 5.2.9 and above 27 ChronoTrack Systems, Inc. MiniTrack User Manual Troubleshooting 7. Troubleshooting The following table lists issues that might arise when using the ChronoTrack system and provides steps for troubleshooting. Issue Steps to Resolution Controller will not connect to CCSLite Antenna will not report connected on controller Wireless numeric keypad is not working USB device not recognized Updated: May 2012 • Disable all firewalls on the PC • Make sure that the PC IP address is in the range 172.20.23.2-49 • Check the cable connections at controller and antenna • Swap ports to confirm working antenna and cables • Verify the correct device model/brand; see System Specifications • Ensure the device is powered on (power switch on back of keyboard) • Press ‘.’ (period) on the keypad to test connectivity; an audible beep should sound if the device is connected • To confirm the controller recognizes your USB device, insert the USB into the MiniTrack after it has completed the boot sequence • It should beep (10 to 20 seconds) or give an error alert (if you have one of the known directory structures on the drive). • If neither of the above happens, you will need to use a different USB drive. Relevant S/W Ver: 5.2.9 and above 28 ChronoTrack Systems, Inc. MiniTrack User Manual Appendix 8. Appendix 8.1 System Specifications DOT regulations prohibit the shipping of lithium batteries by aircraft or vessel. Shipped controllers must include the following label: “LITHIUM BATTERIES: FORBIDDEN FOR TRANSPORT ABOARD AIRCRAFT AND VESSEL”. FCC Part 15 Regulations Caution – Any changes or modifications to this system without the express permission of ChronoTrack Systems will void the user’s authority to operate this equipment. Component D-Tag Interrogator (“Gator”) D-Tag Mini Interrogator (“MiniGator”) ChronoTrack Controller Cable Sets (Short/Long) Specification • • • • • • • • • • • • • • • • • • • • • • AC Power Cable Power Brick Wireless number keypad (optional) Updated: May 2012 • • • • • • • • • • • ADA-compliant Physical dimensions: 42”(L)x33”(W)x1.25”(H) Weight: 27lbs NOT ADA-compliant Physical dimensions: 36”(L)x14”(W)x1.25”(H) Weight: 12lbs MiniTrack provides four ports About 2 hours per Ryobi #P104 battery LCD with keypad Four powered USB A ports One USB B port Two LAN ports LED system status indicators Buzzer 24V DC connection Physical dimensions: 16.0"(L)x13.0"(W)x6.9"(H) Weight (no batteries): 12lbs Weight (with batteries): 16lbs Belden 7808R BNC-Male to BNC-Male Short set for connecting up to 14 feet of linked Gators Long set for connecting up to 14-28 feet of linked Gators 3-prong grounded male plug (NEMA 5-15) to 3pin shroud female (IEC-320 C13) 14’ AWG 18/3 SJT Input: 100-240V, 50/60Hz, 1.5A AC Output: +24V, 2.5A DC Logitech N305 Physical dimensions 6.7 x 2.8 x 8.8 inches Weight: 10.6 ounces Extended 3 year battery life Plug-in receiver for numeric entry 2.4 GHz connection Relevant S/W Ver: 5.2.9 and above 29 ChronoTrack Systems, Inc. MiniTrack User Manual • Index ~30’ (~9m) range 9. Index announcer line, 24 rewind, 21 Auto Save, 22 saving files, 22 bib file, 24 SimpleClient direct socket, 25 Internet server mode, 20 file formats, 22 server connection, 20 filter data, 23 stop, 21 Internet server mode, 20 streaming data, 21 invalidated tags, 22 tag ranges, 23 load controller files, 24 time interval, 25 local network mode, 20 virtual points, 23 play, 21 Updated: May 2012 Relevant S/W Ver: 5.2.9 and above 30
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 34 Producer : GPL Ghostscript 8.64 Create Date : 2012:07:19 16:03:41-05:00 Modify Date : 2012:07:19 16:03:41-05:00 Title : Microsoft Word - miniTrack_UserManual_v1.6-FCC-IC3.docx Creator : PScript5.dll Version 5.2.2 Author : Geoff MochauEXIF Metadata provided by EXIF.tools