Status Indication Pet-Immune PIR Motion Detector Pet-Immune Function Illustration Meaning Display Blinks continuously Self testing Blinks once Intrusion detected Blinks twice Testing mode is finished, the detector enters power-saving mode Blinks once every 3 seconds Low battery, please replace the battery as soon as possible 2m MD9100 9m 1m User Manual 2m IMPORTANT: If you keep a pet at home, make sure the detector is installed at the upright position to achieve pet-immune function. Introduction Tamper switch MD9100 motion detector adopts unique design with dual Infrared sensor effectively identify interference signal from body movement signals. It can reduce false alarm rate caused by pets under Working Mode AA 1.5V LR6 AA 1.5V LR6 infrared sensors and intelligent analysis algorithm which 20kgs or other interfering objects. The detector is suitable for Testing Mode Press the test button, the detector enters testing mode and detects once every 10 seconds. After 3 minutes, the status indicator blinks twice, and the detector switches to power saving mode. Status indicator lobby, hallway detection with a detective range of 0-9 m at front. With low power feedback function, the users will get SMS alert Infrared sensor: It detects the infrared rays released by human or push message for low battery if the detector has been body motion, please don’t touch the surface and always keep it connected to a GSM or Wi-Fi alarm system. clean. Power Saving Mode If the PIR motion detector detects movements twice in 3 minutes, it automatically goes into a sleep state. If there is no movement detected in next 3 minutes, it will switch from sleep state to arm. During the 3 minutes, the detector won’t be active and send any signals to the control panel. As long as there is a movement detected within 3 minutes, the duration of power saving mode will be extended. Tamper switch: Once the case is opened in working mode, the tamper switch is triggered and then generates an alarm signal. Product Overview 1. Detection window Detection Range 2. Status indicator 3. Test button Case 1: Initial start and then arm. 4. Double-sided tape 3m stick place 5. Bracket slot 6m Case 2: Press the test button and then arm. 9m 3 minutes later 2m Top view Side view Sleep after detecting human movement twice. No human movement within 3 minutes Switch from sleep to arm. Pairing to Control Panel Step 1: The ideal mounting height of the motion detector is 2 FCC STATEMENT meters from the floor. It is suggested to mount it at the corner of 1.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: the wall or just stick it to the wall by using the supplied 3M sticker. Control panel enters pairing state Make the control panel in pairing state. Press the test button Press the test button on the back of the detector twice, the control panel beeps once to indicate a successful pairing. (1)This device may not cause harmful interference. (2)This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 2m Ground Note: If the control panel beeps twice when the above operation is done, it means the detector has been paired already. Step 2: After mounting the detector, please walk from left to right in the room for a test; The status indicator will blink once when motion is detected. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Test It is to check whether the PIR motion detector can work properly or not. Arm the system Make sure the alarm system is in armed state. Trigger an alarm Press the test button until an alarm is triggered. The detector is proved to be connected successfully and ready for installation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Note: This PIR motion detector can also be mounted at special location by using the supplied bracket and screw kits. Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Specifications Installation Power Supply DC 3V (AA 1.5V LR6 battery x 2 pcs) Important: Avoid installing the motion detector directly toward Static Current <50 uA windows or near heat sources, such as heat extraction units, air- Alarm Current <9.5 mA condition, micro-wave oven, refrigerator etc. Also try to avoid Detection Scope 9m/110° placing two motion detectors in the opposite of each other and Pet Immunity <20kgs don’t place them in each other ’s detection range. Transmitting Distance <80 m (open area/ no interference) Radio Frequency 868 MHz or 915 MHZ (±75KHz) Housing Material ABS plastic Operating Condition Temperature: -10°C ~+ 55°C ON Relative Humidity: <80% (non-condensing) Detector Dimensions (L x W x H) 108 x 52 x 36.8 mm Bracket Dimensions (L x W x H) 52 x 30 x 26.5 mm Ver: MD9100-UM-EN-V1.0 2015 SMANOS HOLDING LTD. All Rights Reserved.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Administrator Create Date : 2015:04:15 15:46:59+08:00 Modify Date : 2015:04:20 08:52:19+08:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Format : application/pdf Creator : Administrator Title : MD9100-UM-EN-V1.1.cdr Creator Tool : CorelDRAW X7 Metadata Date : 2015:04:20 08:52:19+08:00 Producer : Corel PDF Engine Version 17.0.0.491 Document ID : uuid:c07cae2a-8fea-4da0-9814-d6a286819b89 Instance ID : uuid:77fa0f3a-1309-4619-8f3c-44a916228126 Page Count : 2 Profile CMM Type : Lino Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : IEC Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : HP Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract)EXIF Metadata provided by EXIF.tools