Chungear Co CE10307 Ceiling fan remote Controller (Transmitter) User Manual

Chungear Industrial Co Ltd Ceiling fan remote Controller (Transmitter)

User Manual

Download: Chungear Co CE10307 Ceiling fan remote Controller (Transmitter) User Manual
Mirror Download [FCC.gov]Chungear Co CE10307 Ceiling fan remote Controller (Transmitter) User Manual
Document ID2779463
Application ID6aU1rrd173uHVkfwa2/Ueg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize16.7kB (208771 bits)
Date Submitted2015-10-12 00:00:00
Date Available2015-10-12 00:00:00
Creation Date2015-09-21 10:03:49
Producing SoftwaredoPDF Ver 7.3 Build 382 (Windows XP Professional Edition (SP 3) - Version: 5.1.2600 (x86))
Document Lastmod2015-10-01 18:54:42
Document TitleUser Manual

DC POWER CEILING FAN REMOTE CONTROL MANUAL
LEARNING PROCESS
NOTE: This unit is to be used for the control of DC power ceiling fan and in an AC110/120V 60Hz power
supply only.
Step: 1 Open the remote battery cover and install
CR2032*2pcs Lithium batteries.
Step: 2. Within 30 seconds of turning the Receivers AC
power ON. use a ball pen to press and hold the Set key about
5 seconds.Once the receiver has detected the frequency, the
receiver will make sound, Bi Bi, twice. This will indicate the
receiver has learned the frequency that was previously
selected on the transmitter.
Note: After the AC power is on, do not press any other button on the transmitter before setting learning. Doing so will
cause the procedure to fail.
After completing the steps above, you should be able to operate the ceiling fan and light. If the fan is not responding
to the transmitter, please turn the power off to the receiver. And repeat step 2.
LIGHT FUNCTION SELECT SWITCH
If installed energy light onto ceiling fan, please slide the dip switch ,light function
select switch, to “O” position. If installed tungsten light onto ceiling fan, please
slide the “light function select switch” to “D” position.
FUCNCTIONS OF WALL REMOTE CONTROL
LED for show fan or light’s function setting
FAN key : press and turn fan off
: fan speed control key
press the key
or key
each time for change fan speed
light control key:
ON/OFF- Press
and release immediately to turn on or off dwon light.
DIMMER-Press
or
and hold to dim or brighten light to the desired level and
release.
(Tungsten only and light function select switch on dimmer position.)
TR205A
1hr:Setting up that the ceiling fan will turn off after 1 hour automatically
3hr:Setting up that the ceiling fan will turn off after 3 hours automatically
6hr:Setting up that the ceiling fan will turn off after 6 hours automatically
Home Shield – Press and hold the buttons for 3 seconds.
randomly turn on and off while you are away home.
Fan will be off and the light will
: Walk Away Light Delay – Tap once ‐ the light and fan turn off after 1 minute automatically.
Press the key for set fan speed for making natural wind.
Press the key for forward airflow of ceiling fan
Touch icon for reverse airflow of ceiling fan.
To assure continued FCC compliance:
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
--Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult
the dealer or an experienced radio/TV technician for help.
CAUTION:
Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to
operate the equipment.
FCC ID:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Page Mode                       : UseNone
XMP Toolkit                     : 3.1-702
Create Date                     : 2015:09:21 10:03:49+08:00
Modify Date                     : 2015:10:01 18:54:42+08:00
Metadata Date                   : 2015:10:01 18:54:42+08:00
Producer                        : doPDF Ver 7.3 Build 382 (Windows XP Professional Edition  (SP 3) - Version: 5.1.2600 (x86))
Format                          : application/pdf
Document ID                     : uuid:8f23f97e-0c38-42c6-b332-597dabfedcba
Instance ID                     : uuid:7649090f-1cee-4a11-ba13-393cb1dae66e
Page Count                      : 2
Page Layout                     : OneColumn
EXIF Metadata provided by EXIF.tools
FCC ID Filing: KUJCE10307

Navigation menu