CipherLab 1660 Barcode Scanner User Manual
CipherLab Co., Ltd. Barcode Scanner
User manual
1660 Barcode Scanner Setup labels included. Copyright © 2008 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided under a license agreement containing restrictions on use and disclosure and is also protected by copyright law. Reverse engineering of the software is prohibited. Due to continued product development this information may change without notice. The information and intellectual property contained herein is confidential between CIPHERLAB and the client and remains the exclusive property of CIPHERLAB CO., LTD. If you find any problems in the documentation, please report them to us in writing. CIPHERLAB does not warrant that this document is error-free. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior written permission of CIPHERLAB CO., LTD. For product consultancy and technical support, please contact your local sales representative. Also, you may visit our web site for more information. The CipherLab logo is a registered trademark of CIPHERLAB CO., LTD. Microsoft, Windows, and the Windows logo are registered trademarks of Microsoft Corporation in the United States and/or other countries. Bluetooth is a trademark of Bluetooth SIG, Inc., U.S.A. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. The editorial use of these names is for identification as well as to the benefit of the owners, with no intention of infringement. CIPHERLAB CO., LTD. Website: http://www.cipherlab.com IMPORTANT NOTICES FOR USA This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. You are cautioned that changes or modifications not expressly approved by the party responsible FOR CANADA could void your authority to operate the equipment. for compliance This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled "Digital Apparatus," ICES-003 of Industry Canada. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux appareils numeriques de Classe B prescrites dans la norme sur le material brouilleur: "Appareils Numeriques," NMB-003 edictee par l'Industrie. FOR HAND-HELD PRODUCT WITH RF FUNCTIONS This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. It only operated in hand-held used. If you only transfer data to Host by Bluetooth, please keep the minimum distance 20 cm between machine & your body. FOR PRODUCT WITH LASER Per FDA and IEC standards, the scan engines described in this manual are not given a laser classification. However, the following precautions should be observed: CAUTION This laser component emits FDA / IEC Class 2 laser light at the exit port. Do not stare into beam. SAFETY PRECAUTIONS RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. The use of any batteries or charging devices, which are not originally sold or manufactured by CipherLab, will void your warranty and may cause damage to human body or the product itself. DO NOT disassemble, incinerate or short circuit the battery. DO NOT expose the scanner or the battery to any flammable sources. For green-environment issue, it's important that batteries should be recycled in a proper way. Under no circumstances, internal components are self-serviceable. The charging and communication cradle uses an AC power adaptor. A socket outlet shall be installed near the equipment and shall be easily accessible. Make sure there is stable power supply for the mobile computer or its peripherals to operate properly. CARE & MAINTENANCE Use a clean cloth to wipe dust off the scanning window and the body of the scanner as well as the cradle. DO NOT use/mix any bleach or cleaner. If you want to put away the scanner for a period of time, download the collected data to a host computer when in the memory mode, and then take out the battery. Store the scanner and battery separately. When the scanner resumes its work, make sure the battery is fully charged before use. If you shall find the scanner malfunctioning, write down the specific scenario and consult your local sales representative. RELEASE NOTES Version Date Notes 0.94 Mar. 19, 2008 0.93 Feb. 26, 2008 0.92 Feb. 15, 2008 0.91 Feb. 14, 2008 Separate manual for1660 for review 0.90 Jan. 25, 2008 Draft for use in pilot production Modified: section 1.6.6 Aiming Mode – Timeout (1~15 sec) New: section 4 Changing Symbology Settings – ISBT 128 Modified: remove 1662 Modified: section 2.1.3 Keyboard Settings – illustration * The documentation is subject to change without prior notice. CONTENTS IMPORTANT NOTICES ...................................................................................................................... - 3 For USA .......................................................................................................................................... - 3 For Canada .................................................................................................................................... - 3 For Hand-held Product with RF Functions ................................................................................... - 3 For Product with Laser .................................................................................................................. - 4 Safety Precautions ........................................................................................................................ - 4 Care & Maintenance ..................................................................................................................... - 4 RELEASE NOTES .............................................................................................................................. - 5 INTRODUCTION .................................................................................................................................... 1 Inside the Package............................................................................................................................ 2 Product Highlights ............................................................................................................................. 2 Quick Start ........................................................................................................................................... 3 Enter Configuration Mode................................................................................................................. 4 Exit Configuration Mode.................................................................................................................... 4 Default Settings................................................................................................................................. 5 Save User Settings as Defaults ................................................................................................... 5 Restore User Defaults.................................................................................................................. 5 Restore System Defaults ............................................................................................................. 5 Read a Setup Label........................................................................................................................... 6 Configure Parameters.................................................................................................................. 6 List the Current Settings .............................................................................................................. 9 UNDERSTANDING THE BARCODE SCANNER .................................................................................... 11 1.1 Battery ....................................................................................................................................... 11 1.1.1 Installing the Battery........................................................................................................11 1.1.2 How to Operate the Scanner ...........................................................................................12 1.1.3 Auto Power Off..................................................................................................................12 1.2 Memory ..................................................................................................................................... 13 1.2.1 Transmit Buffer ................................................................................................................13 1.2.2 Memory Mode ..................................................................................................................13 1.3 LED Indicator.............................................................................................................................15 1.3.1 Good Read LED ................................................................................................................16 1.4 Beeper ....................................................................................................................................... 16 1.4.1 Beeper on 1660 ...............................................................................................................16 1.4.2 Beeper Volume.................................................................................................................17 1.4.3 Good Read Beep ..............................................................................................................17 1.4.4 Low Battery Alarm ............................................................................................................18 1.5 Send “NR” to Host ....................................................................................................................19 1.6 Scan Modes ..............................................................................................................................19 1.6.1 Continuous Mode .............................................................................................................20 1600 Series Barcode Scanner User Guide 1.6.2 Test Mode .........................................................................................................................21 1.6.3 Laser Mode.......................................................................................................................21 1.6.4 Auto Off Mode...................................................................................................................21 1.6.5 Auto Power Off Mode .......................................................................................................22 1.6.6 Aiming Mode.....................................................................................................................22 1.6.7 Multi-Barcode Mode.........................................................................................................23 1.7 Scanning Timeout.....................................................................................................................23 1.8 Delay between Re-read ............................................................................................................24 1.9 Effective Decoding Area ...........................................................................................................25 1.9.1 Positioning Window..........................................................................................................25 1.9.2 Adjusting Window.............................................................................................................25 1.10 Negative Barcodes .................................................................................................................27 1.11 Symbologies Supported .........................................................................................................27 1.11.1 Read Redundancy for All Symblogies ...........................................................................28 1.11.2 Addon Security for UPC/EAN Barcodes ........................................................................28 SELECTING OUTPUT INTERFACE ....................................................................................................... 31 2.1 Bluetooth HID............................................................................................................................31 2.1.1 Activate Bluetooth HID & Select Keyboard Type ............................................................32 2.1.2 Reset Connection.............................................................................................................32 2.1.3 Keyboard Settings............................................................................................................33 2.1.4 Inter-Function Delay.........................................................................................................36 2.2 Bluetooth SPP ...........................................................................................................................38 2.2.1 Activate Bluetooth SPP ....................................................................................................38 2.2.2 Inter-Function Delay.........................................................................................................38 2.2.3 ACK/NAK Timeout ............................................................................................................39 SETTING UP BLUETOOTH CONNECTIONS ......................................................................................... 41 3.1 Configuring Bluetooth Settings ................................................................................................42 3.1.1 Sniff Mode (Power-saving)...............................................................................................42 3.1.2 Device Name Broadcasting .............................................................................................42 3.1.3 Authentication ..................................................................................................................43 3.2 Connecting via Bluetooth Dongle ............................................................................................44 3.2.1 Bluetooth HID – Add Bluetooth Device Wizard .............................................................. 44 3.2.2 Bluetooth SPP – Add Bluetooth Device Wizard.............................................................. 44 CHANGING SYMBOLOGY SETTINGS.................................................................................................. 51 4.1 Codabar..................................................................................................................................... 52 4.1.1 Start/Stop Characters Selection .....................................................................................52 4.1.2 Start/Stop Transmission..................................................................................................52 4.1.3 CLSI Conversion ...............................................................................................................53 4.2 Code 25 – Industrial 25 ...........................................................................................................54 4.2.1 Start/Stop Pattern Selection ...........................................................................................54 4.2.2 Checksum Verification .....................................................................................................54 4.2.3 Checksum Transmission..................................................................................................55 4.2.4 Code Length Qualification ...............................................................................................55 4.3 Code 25 – Interleaved 25........................................................................................................57 4.3.1 Start/Stop Pattern Selection ...........................................................................................57 4.3.2 Checksum Verification .....................................................................................................57 4.3.3 Checksum Transmission..................................................................................................58 1600 Series Barcode Scanner User Guide 4.3.4 Code Length Qualification ...............................................................................................58 4.4 Code 25 – Matrix 25 ................................................................................................................60 4.4.1 Start/Stop Pattern Selection ...........................................................................................60 4.4.2 Checksum Verification .....................................................................................................60 4.4.3 Checksum Transmission..................................................................................................61 4.4.4 Code Length Qualification ...............................................................................................61 4.5 Code 39..................................................................................................................................... 63 4.5.1 Start/Stop Transmission..................................................................................................63 4.5.2 Checksum Verification .....................................................................................................63 4.5.3 Checksum Transmission..................................................................................................64 4.5.4 Standard/Full ASCII Code 39 ..........................................................................................64 4.6 Code 93..................................................................................................................................... 65 4.7 Code 128 ..................................................................................................................................65 4.8 EAN-8......................................................................................................................................... 66 4.8.1 Convert to EAN-13............................................................................................................66 4.8.2 Checksum Transmission..................................................................................................67 4.9 EAN-13 ...................................................................................................................................... 68 4.9.1 ISBN Conversion...............................................................................................................68 4.9.2 ISSN Conversion...............................................................................................................69 4.9.3 Checksum Transmission..................................................................................................69 4.10 EAN-128..................................................................................................................................70 4.10.1 Code ID Transmission.................................................................................................... 70 4.10.2 Field Separator (GS Character) .....................................................................................70 4.11 ISBT 128 .................................................................................................................................71 4.12 MSI .......................................................................................................................................... 72 4.12.1 Checksum Verification...................................................................................................72 4.12.2 Checksum Transmission ...............................................................................................72 4.12.3 Code Length Qualification .............................................................................................73 4.13 French Pharmacode...............................................................................................................75 4.13.1 Checksum Transmission ...............................................................................................75 4.14 Italian Pharmacode ................................................................................................................76 4.14.1 Checksum Transmission ...............................................................................................76 4.15 Plessey .................................................................................................................................... 77 4.15.1 Convert to UK Plessey ...................................................................................................77 4.15.2 Checksum Transmission ...............................................................................................77 4.16 RSS Family..............................................................................................................................78 4.16.1 Code ID Selection ..........................................................................................................78 4.16.2 RSS-14............................................................................................................................78 4.16.3 RSS Expanded................................................................................................................79 4.16.4 RSS Limited....................................................................................................................80 4.17 Telepen ................................................................................................................................... 82 4.17.1 Telepen Output – Full ASCII/Numeric ..........................................................................82 4.18 UPC-A....................................................................................................................................... 83 4.18.1 Convert to EAN-13 .........................................................................................................83 4.18.2 System Number Transmission ......................................................................................84 4.18.3 Checksum Transmission ...............................................................................................84 4.19 UPC-E....................................................................................................................................... 85 4.19.1 System Number Selection.............................................................................................85 1600 Series Barcode Scanner User Guide 4.19.2 Convert to UPC-A............................................................................................................86 4.19.3 System Number Transmission ......................................................................................86 4.19.4 Checksum Transmission ...............................................................................................86 DEFINING OUTPUT FORMAT .............................................................................................................. 89 5.1 Letter Case................................................................................................................................ 89 5.2 Character Substitution .............................................................................................................90 5.2.1 Select a Set for Character Substituion ...........................................................................90 5.2.2 Symbologies for Character Substitution (All 3 Sets) ...................................................... 91 5.3 Prefix/Suffix Code.....................................................................................................................96 5.4 Code ID...................................................................................................................................... 97 5.4.1 Select Pre-defined Code ID..............................................................................................97 5.4.2 Change Code ID................................................................................................................98 5.4.3 Clear Code ID Settings ...................................................................................................100 5.5 Length Code............................................................................................................................101 5.6 Multi-Barcode Editor...............................................................................................................104 5.6.1 Edit a Concatenation of Barcodes ................................................................................105 5.6.2 Activate the Concatenation of Barcodes ......................................................................106 APPLYING FORMATS FOR DATA EDITING........................................................................................107 6.1 Format Selection ....................................................................................................................108 6.1.1 Activate Editing Formats................................................................................................108 6.1.2 Exclusive Data Editing....................................................................................................109 6.2 Editing Format.........................................................................................................................110 6.2.1 Select Format to Configure............................................................................................110 6.2.2 Restore Default Format .................................................................................................111 6.2.3 Define Data Criteria .......................................................................................................112 6.2.4 Divide Data into Fields...................................................................................................115 6.2.5 Field Settings..................................................................................................................117 6.2.6 Field Transmission Sequence .......................................................................................121 6.3 Programming Examples .........................................................................................................123 6.3.1 Example I ........................................................................................................................123 6.3.2 Example II .......................................................................................................................123 SPECIFICATIONS ..............................................................................................................................125 NUMERAL SYSTEMS........................................................................................................................127 Decimal System.............................................................................................................................127 Hexadecimal System.....................................................................................................................128 Entering PIN Code for Bluetooth Connection ..............................................................................129 KEYBOARD WEDGE TABLE & ASCII TABLE......................................................................................131 Keyboard Wedge Table .................................................................................................................131 Key Type....................................................................................................................................131 Key Status ................................................................................................................................132 User-defined Scan Code ..........................................................................................................133 ASCII Table.....................................................................................................................................133 HOST SERIAL COMMANDS ..............................................................................................................135 Serial Commands ..........................................................................................................................135 1600 Series Barcode Scanner User Guide Example .........................................................................................................................................136 UPGRADING FIRMWARE ..................................................................................................................137 INTRODUCTION CipherLab’s new small-form-factor 1600 Series Barcode Scanners are specifically designed to answer your mobile demands. The palm-sized 1660 scanners are designed to help accelerate productivity while lowering the total cost of ownership. Intensive data collection jobs are made easier with fast, accurate barcode scanning in various working environments, especially in small businesses. Integrating Bluetooth technology to small-form-factor scanners, the 1660 Bluetooth scanners are ideal for carrying in your pocket, and thus give workers tether-free mobility anytime anywhere and get job done more efficiently. This line of Bluetooth scanners has a range of up to 3 meters and a prolonged battery life that provides up to 30 hours uptime to keep business running. Owing to the compact design, extremely low power consumption, and powerful decoding capability, CipherLab Barcode Scanners are the best choice for the following applications – Receiving in Retail Product labeling & Tracking Shelf Product Replenishment Mobile Point of Sale (POS) Mobile Inventory Management Order Picking & Staging Work-In-Process Tracking Material Flow Control Transportation & Distribution Warehousing Asset Management This manual contains information on operating the scanner and using its features. We recommend you to keep one copy of the manual at hand for quick reference or maintenance purposes. To avoid any improper disposal or operation, please read the manual thoroughly before use. Thank you for choosing CipherLab products! 1600 Series Barcode Scanner User Guide INSIDE THE PACKAGE The items included in the package may be different, depending on your order. Save the box and packaging material for future use in case you need to store or ship the scanner. 1660 Barcode Scanner Manual & Driver CD Note: The Manual & Driver CD includes this manual and Windows-based ScanMaster software for configuration. PRODUCT HIGHLIGHTS Small-form-factor and built tough to survive drop test Most popular barcode symbologies are supported, including Reduced Space Symbology (RSS) Negative barcodes are also supported Seven scan modes are supported, including Aiming Mode and Multi-Barcode Mode User feedback via LED indicator and beeper Beeping tone and duration are programmable for Good Read. Extremely low power consumption 128 KB flash memory for Memory mode operation, storing up to 8192 scans. The 1660 scanner provides up to 4 KB SRAM for reserve buffer, storing up to 256 scans while getting out of range during a Bluetooth connection. Bluetooth Serial Port Profile (SPP) supported – for example, the 1660 scanner can transmit the scanned data to a Bluetooth-enabled computer or PDA. Bluetooth Human Interface Device (HID) supported – for example, the 1660 scanner can transmit the scanned data to a Bluetooth-enabled computer or PDA, as keyboard input. Programmable parameters include data output format, editing format, symbologies, etc. Firmware upgradeable Quick Start The configuration of the scanner can be done by reading the setup labels contained in this manual or via the ScanMaster software. This section describes the procedure of configuring the scanner by reading the setup barcodes and provides some examples for demonstration. Note: If RS-232 or Bluetooth SPP is selected for output interface, the host can directly send serial commands to configure the scanner. Steps Action User Feedback if Successful Power on the scanner… The scanner will respond with a long beep (high tone). Note: Upon powering up, the 1660 scanner will try to establish a connection with a Bluetooth device dongle. Refer to Chapter 3 – Setting up Bluetooth Connections for details. Enter the Configuration Mode… The scanner will respond with six beeps (high-low tone repeats three times), and its LED indicator will be flashing red. Read a Setup label… The scanner will respond with two beeps (low-high tone) if reading a normal label. For example, Exit the Configuration Mode… Same as for Enter the Configuration Mode. OR The scanner will automatically restart itself… Same as for Power on the scanner. When any configuration error occurs... The scanner will respond with one long beep with a low tone. 1600 Series Barcode Scanner User Guide ENTER CONFIGURATION MODE For the scanner to enter the configuration mode, you must have it read the "Enter Setup" label, which can be located at the bottom of almost every even page of this manual. The scanner will respond with six beeps and its LED indicator will become flashing red after reading the label. Enter Setup For configuring scanner parameters, see “Read a Setup Label” below. EXIT CONFIGURATION MODE For the scanner to exit the configuration mode, you must have it read the “Update” label, which can be located at the bottom of almost every odd page of this manual. If you want to exit the configuration mode without saving any changes, have the scanner read the “Abort” label instead. Just like reading the “Enter Setup” label, the scanner will respond with six beeps and its LED indicator will become flashing red after reading the label. Wait for a few seconds for the scanner to restart itself. Update Abort ! DEFAULT SETTINGS SAVE USER SETTINGS AS DEFAULTS For the scanner to keep the customized settings as user defaults, you must have it read the “Save as User Defaults” label. Save as User Default RESTORE USER DEFAULTS For the scanner to restore the user defaults, which you have saved earlier, you must have it read the “Restore User Defaults” label. The scanner will issue two beeps after reading the label, and all the parameters of the scanner will return to their customized values. Restore User Defaults RESTORE SYSTEM DEFAULTS For the scanner to restore the factory defaults, you must have it read the “Restore System Defaults” label. The scanner will issue two beeps after reading the label, and all the parameters of the scanner will return to their default values. Restore System Defaults Note: The system default value (if there is) for each setting is indicated by an asterisk “*”. 1600 Series Barcode Scanner User Guide READ A SETUP LABEL CONFIGURE PARAMETERS For most of the scanner parameters, only one read is required to set them to new values. The scanner will respond with two beeps when each parameter is set successfully. But for a number of special parameters, multiple reads are required to complete the setting. In this case, the scanner will respond with a short beep to indicate it needs to read more setup labels. These special parameters may require reading one or more (1) numeric labels, say, for keyboard type, inter-character delay, length qualification, or (2) hexadecimal labels, say, for character strings as prefix, suffix, etc. Note: When “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type. To complete the configuration of these special parameters, it requires reading the “Validate” label, and the scanner will respond with two beeps (low-high tone) to indicate the input values are validated. ! NUMERIC PARAMETERS Steps Action User Feedback if Successful Power on the scanner... The scanner will respond with a long beep (high tone). Enter the Configuration Mode… The scanner will respond with six beeps (high-low tone repeats three times), and its LED indicator will become flashing red. Read a Setup label... The scanner will respond with two beeps (low-high tone) if reading a normal label. For example, Normal label Normal label The scanner will respond with one short beep if reading a special label such as “Max. Length”, indicating the setup requires reading more labels. Special label Decimal label or labels The scanner will respond with two beeps (low-high tone) when the input values are validated. Exit the Configuration Mode… Same as for Enter the Configuration Mode. OR 1600 Series Barcode Scanner User Guide CHARACTER STRING PARAMETERS Steps Action User Feedback if Successful Power on the scanner... The scanner will respond with a long beep (high tone). Enter the Configuration Mode… The scanner will respond with six beeps (high-low tone repeats three times), and its LED indicator will become flashing red. Read a Setup label... The scanner will respond with one short beep if reading a special label such as “Prefix Code”, indicating the setup requires reading more labels. For example, Special label When “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type. Read the “Hexadecimal Value” label for the desired character string. For example, read “2” and “B” for the scanner to prefix the character “+”. Hexadecimal labels The scanner will respond with two beeps (low-high tone) when the input values are validated. Exit the Configuration Mode… OR Same as for Enter the Configuration Mode. ! LIST THE CURRENT SETTINGS The current settings of all scanner parameters can be sent, via RS-232 or Bluetooth SPP, to the host computer for user inspection. The listing includes ten pages as shown below. You can select the page of interest by reading the “Page x” label. List Page 1 List settings regarding Interface, Buzzer, and Other Scanner Parameters List Page 2 List settings regarding Prefix, Postfix, and Length Code Setting List Page 3 List settings regarding Code ID List Page 4 List settings regarding: Readable Symbologies List Page 5 List settings regarding Symbology Parameters (1/3) List Page 6 List settings regarding Symbology Parameters (2/3) List Page 7 List settings regarding Symbology Parameters (3/3) 1600 Series Barcode Scanner User Guide List Page 8 List settings regarding Editing Format 1 List settings regarding Editing Format 2 List Page 10 List settings regarding Editing Format 3 List Page 11 List settings regarding Editing Format 4 List Page 12 List settings regarding Editing Format 5 10 Chapter 1 UNDERSTANDING THE BARCODE SCANNER This chapter explains the features and usage of the barcode scanner. IN THIS CHAPTER 1.1 Battery..................................................................... 1.2 Memory.................................................................... 1.3 LED Indicator ............................................................ 1.4 Beeper ..................................................................... 1.5 Send "NR" to Host...................................................... 1.6 Scan Modes .............................................................. 1.7 Scanner Time-out ...................................................... 1.8 Delay between Re-read............................................... 1.9 Effective Decoding Area .............................................. 1.10 Negative Barcodes ................................................... 1.11 Symbologies Supported ............................................ 11 13 15 16 19 19 23 24 25 27 27 1.1 BATTERY The scanner is powered by two AAA Alkaline batteries. During normal operation, the scanner can work for over 30 hours or 28,000 scans (based on UPC-E barcodes, 1 scan per 5 seconds). For intensive data collection, you may prepare spare batteries for non-stop operation. Note: The 1660 scanner can be configured to save battery power. Refer to settings of “Auto Power Off”, “Sniff Mode”, as well as “Low Battery Alarm”. 1.1.1 INSTALLING THE BATTERY 1) Hold the scanner face down in one hand. 2) Press the battery lid release and slide the battery lid. 3) Remove the battery lid by the other hand. 4) Install two AAA Alkaline batteries into the battery compartment, each in the right direction. 11 Update 1600 Series Barcode Scanner User Guide 5) Replace the battery lid and lock it firmly. 1.1.2 HOW TO OPERATE THE SCANNER To turn on the scanner, press the [Delete] key for 3 seconds, and the scanner will respond with a long beep (high tone). To turn off the scanner, press the [Delete] key for 1.5 seconds. The scanner will respond with short beep (high tone) and the LED will become solid green, then go off, and finally become solid red. Release the key then. To delete the last collected data, press the [Delete] key. The scanner will respond with short beep (high tone) and the LED will become solid green. Before the LED goes off (within 1 second), press the [Delete] key again to confirm the deletion. 1.1.3 AUTO POWER OFF Specify the time interval (1~254 min.; 0= disable) for the scanner to wait for a computer to establish a connection via a Bluetooth dongle. By default, the 1660 scanner will stay active for 10 minutes waiting for a connection request. If it fails to connect within the time interval, the scanner will automatically turn off in order to conserve battery power (you will hear three short beeps, tone descending from high to low). Press the [Delete] key for 3 seconds to turn it on. On your computer, you will have to search Bluetooth devices again. Once a Bluetooth connection is established successfully, the scanner will stay active as long as the COM port is opened by a host application. Auto Off after 0~254 minutes (*10) 1) Read the label above to specify the time interval before the scanner automatically turns off. 2) Read the “Decimal Value” label on page 123. For example, read “1” and “5” for the scanner to automatically turn off after being idle for 15 minutes. 3) Read the “Validate” label on the same page to complete this setting. 12 Enter Setup Chapter 1 ! Ζ 1.2 MEMORY The collected data can be sent back to a host computer one by one via the transmit buffer (SRAM) or stored in flash memory when the scanner is set to Memory mode. 1.2.1 TRANSMIT BUFFER The 1 KB transmit buffer on the scanner can store up to 64 scans based on EAN-13 barcodes. When it is used up, the scanner will respond with one long beep (low tone) as a warning. You are advised to get back to range if using the Bluetooth scanner. 1.2.2 MEMORY MODE The scanner keeps 128 KB flash memory for memory mode operation. When the 1660 scanner is in memory mode, it means Bluetooth connection is disabled. Enable Memory Mode *Disable Memory Mode Warning: Bluetooth cannot work unless memory mode is disabled. MEMORY DATA DELAY You may set a delay between each data record while transmitting data back to the server. *None 250 ms 13 Update 1600 Series Barcode Scanner User Guide 500 ms 1 sec 2 sec 3 sec 5 sec 8 sec SEND DATA The 128 KB flash memory on the scanner can store up to 8192 scans based on EAN-13 barcodes. When it is used up, the scanner will respond with two short beeps (low-high tone) as a warning. You are advised to send data to the server immediately. Select a desired interface for transmission. For example, disable memory mode and use Bluetooth SPP to transmit data. Send Data 14 Enter Setup Chapter 1 ! Ζ CLEAR DATA & CONFIRM Even though data has been sent back to the server, the flash memory is still occupied unless you erase the memory by having the scanner read two labels – “Clear Data” and “Confirm”. 1) Read the “Clear Data” label to clear the flash memory. 2) Read the “Confirm” label to confirm the action. Clear Data Confirm 1.3 LED INDICATOR The triple-color LED on top of the scanner is used to provide user feedback. For example, the LED becomes solid red and goes off quickly (= Standby mode) upon powering on or running out of transmit buffer. You may tell the difference by the beeps – for example, you will hear a long beep of high tone when powering on the scanner, and a long beep of low tone when the transmit buffer becomes full. LED – Red/Green/Blue Meaning Green, and goes off quickly, and becomes red, and finally goes off when the [Delete] key is released. Power off Red, and goes off quickly Power on, with one long beep (high tone) Transmit buffer full, with one long beep (low tone) Memory full, with two short beeps (low-high tone) Bluetooth connection out of range, with two beeps (high-low tone) Green, and goes off quickly Good Read, beeper pitch and duration programmable Flashing blue (On/Off ratio 1:1) No Bluetooth connection (flashing slowly) Dynamic PIN code request from host (flashing quickly) Flashing blue (On/Off ratio 1:6) Bluetooth connection established Flashing blue and red Dynamic PIN code input error Flashing red Configuration Mode 15 Update 1600 Series Barcode Scanner User Guide 1.3.1 GOOD READ LED *Enable Good Read LED Disable Good Read LED 1.4 BEEPER The scanner has a buzzer to provide user feedback in various operating conditions. 1.4.1 BEEPER ON 1660 Beeping Meaning One long beep, high tone Power on One short beep, low tone Power off One short beep, high tone Good Read Programmable, default to 4 KHz Six short beeps High-low tone repeats three times Enter Configuration Mode Exit Configuration Mode Two short beeps, low-high tone Setup label read successfully One short beep, high tone More setup label required One long beep, low tone Transmit Buffer Full Configuration Error (Wrong label…) Two short beeps, low-high tone Memory Mode – Memory Full Two long beeps, high-low tone Multi-Barcode Mode – Buffer Full Three short beeps Tone ascending from low to high Bluetooth connection established Bluetooth connection resumed Two beeps, high-low tone Bluetooth connection out of range Three short beeps, low tone No Bluetooth connection 16 Enter Setup Chapter 1 ! Ζ 1.4.2 BEEPER VOLUME Mute Minimum Volume Medium Volume *Maximum Volume 1.4.3 GOOD READ BEEP FREQUENCY 8 kHz * 4 kHz 2 kHz 1 kHz 17 Update 1600 Series Barcode Scanner User Guide DURATION *Shortest Shorter Longer Longest 1.4.4 LOW BATTERY ALARM By default, “2.6 V (Alkaline)” is selected for low battery level. When the battery level inside the 1660 scanner reaches 2.6 V, it will activate the beeper to give a warning. If you are using Ni-MH batteries, select “2.1 V (Ni-MH)”. No Alarm * 2.6 V (Alkaline) 2.1 V (Ni-MH) 18 Enter Setup Chapter 1 ! Ζ 1.5 SEND “NR” TO HOST This feature only works when Keyboard Wedge, RS-232, Bluetooth HID, or Bluetooth SPP is selected for output interface. You may have the scanner send the “NR” string to the host to notify the No Read event. Enable *Disable 1.6 SCAN MODES There are eight scan modes supported – select the scan mode that best suits the requirements of a specific application. Refer to the comparison table below. Scan Mode Start to Scan Always Continuous mode Test mode Press trigger once Stop Scanning Hold trigger Laser mode Auto Off mode Auto Power Off mode Release trigger Press trigger once Barcode Timeout being read Aiming mode Multi-Barcode mode Press trigger twice Note: By default, the scan mode is set to Laser mode. 19 Update 1600 Series Barcode Scanner User Guide 1.6.1 CONTINUOUS MODE The scanner is always scanning. To decode the same barcode repeatedly, move away the scan beam and target it at the barcode for each scanning. Note: Refer to “Delay between Re-read”. Continuous Mode DECODING DELAY Set the time interval between each decoding. *Disable 0.5 sec 1 sec 2 sec 20 Enter Setup Chapter 1 ! Ζ 1.6.2 TEST MODE The scanner is always scanning. Capable of decoding the same barcode repeatedly, for testing purpose. Test Mode 1.6.3 LASER MODE The scanner will start scanning once the trigger is hold down. The scanning won't stop until (1) a barcode is decoded, (2) the pre-set timeout expires, or (3) you release the trigger. Note: Refer to “Scanning Timeout”. *Laser Mode 1.6.4 AUTO OFF MODE The scanner will start scanning once the trigger is pressed. The scanning won't stop until (1) a barcode is decoded, and (2) the pre-set timeout expires. Note: Refer to “Scanning Timeout”. Auto Off Mode 21 Update 1600 Series Barcode Scanner User Guide 1.6.5 AUTO POWER OFF MODE The scanner will start scanning once the trigger is pressed. The scanning won't stop until the pre-set timeout expires, and, the pre-set timeout period re-counts after each successful decoding. Note: Refer to “Delay between Re-read” and “Scanning Timeout”. Auto Power Off Mode 1.6.6 AIMING MODE The scanner will aim at a barcode once the trigger is pressed, and start scanning when the trigger is pressed again within one second. The scanning won't stop until (1) a barcode is decoded, and (2) the pre-set timeout expires. Aiming Mode AIMING TIMEOUT You can limit the aiming time interval (1~15). By default, the scanner time-out is set to 1 second. Aiming Time-Out after 1~15 seconds (*1) 1) Read the label above to specify the time interval before aiming ends. (It is set to 1 by default.) 2) Read the “Decimal Value” label on page 123. For example, read “1” and “0” for the scanner to automatically shut down after being idle for 10 seconds. 3) Read the “Validate” label on the same page to complete this setting. 22 Enter Setup Chapter 1 ! Ζ 1.6.7 MULTI-BARCODE MODE The scanner will be scanning as long as the trigger is held down, capable of decoding not only one single barcode but a concatenation of unique barcodes. The scanning won't stop until you release the trigger. Multi-Barcode Mode Note: (1) A barcode is considered unique when its Code Type or data is different from others. (2) Multi-Barcode Mode cannot work with “Multi-Barcode Editor”. 1.7 SCANNING TIMEOUT Specify the scanning time interval (1~254 sec.; 0= disable) when the scan mode is set to any of the following – Laser mode Auto Off mode Auto Power Off mode Aiming mode Scanner Time-Out after 0~254 seconds (*10) 1) Read the label above to specify the time interval before the scan engine times. 2) Read the “Decimal Value” label on page 123. For example, read “1” and “5” for the scanner to automatically shut down after being idle for 15 seconds. 3) Read the “Validate” label on the same page to complete this setting. 23 Update 1600 Series Barcode Scanner User Guide 1.8 DELAY BETWEEN RE-READ This is also referred to as the “Blocking Time”, which is used to prevent the scanner from accidentally reading the same barcode twice when the scan mode is set to any of the following – Continuous mode Auto Power Off mode 100 ms 200 ms * 400 ms 800 ms 1 sec 2 sec 3 sec 5 sec 24 Enter Setup Chapter 1 ! Ζ 1.9 EFFECTIVE DECODING AREA By default, the effective decoding area is 100% covered by the scanned area. However, you may narrow down the decoding area to prevent reading the wrong barcode when a number of barcodes are printed closely. The scanner will only read barcodes that appear in the effective decoding area. Read the label “Centering On” and specify the percentage to narrow down the decoding area. For example, read “Left 10%” and then “Right 30%” for the scanner to decode barcode “A” only. 1.9.1 POSITIONING WINDOW Centering On *Centering Off 1.9.2 ADJUSTING WINDOW PERCENTAGE FOR LEFT HALF *Left 50% 25 Update 1600 Series Barcode Scanner User Guide Left 40% Left 30% Left 20% Left 10% PERCENTAGE FOR RIGHT HALF Right 10% Right 20% Right 30% Right 40% *Right 50% 26 Enter Setup Chapter 1 ! Ζ 1.10 NEGATIVE BARCODES Normally, barcodes are printed with the color of the bars darker than that of the spaces. But for negative barcodes, they are printed in the opposite sense just like negative films. The spaces of negative barcodes are printed with a color darker than that of the bars. You can configure the scanner to be able to read negative barcodes. Enable *Disable 1.11 SYMBOLOGIES SUPPORTED Most of the popular barcode symbologies are supported, as listed below. Each can be individually enabled or disabled. The scanner will automatically discriminate and recognize all the symbologies that are enabled. Refer to Chapter 4 Changing Symbology Settings for details of each symbology. Codabar* Industrial 25* Interleaved 25* Matrix 25 Code 39* Code 93* Code 128* EAN-8* EAN-8 Addon 2 & 5 EAN-13* EAN-13 Addon 2 & 5 EAN-128 French Pharmacode Italian Pharmacode MSI Plessey RSS-14 Limited Telepen UPC-A* UPC-E* RSS Expanded RSS UPC-A Addon 2 & 5 UPC-E Addon 2 & 5 Note: The symbologies, followed by an asterisk mark, are enabled by default. 27 Update 1600 Series Barcode Scanner User Guide 1.11.1 READ REDUNDANCY FOR ALL SYMBLOGIES Select the level of reading security. For example, If "No Redundancy" is selected, one successful decoding will make the reading valid and induce the "READER Event". If "Three Times" is selected, it will take a total of four consecutive successful decodings of the same barcode to make the reading valid. The higher the reading security is (that is, the more redundancy the user selects), the slower the reading speed gets. It is obvious that the more redundancy you select, the higher the reading security is, and thus, the slower the reading speed becomes. You will have to compromise between reading security and decoding speed. *No Redundancy One Time Two Times Three Times 1.11.2 ADDON SECURITY FOR UPC/EAN BARCODES You may like to enforce read redundancy (0~30 times) on UPC/EAN barcodes with addons only. Note: UPC/EAN Addon 2 and Addon 5 must be enabled individually for this setting to take effect. Addon Security Level (*0 ~ 30) 28 Enter Setup Chapter 1 ! Ζ 1) Read the label above to specify the read redundancy when missing add-ons while scanning UPC/EAN barcodes. (It is set to 0 by default.) 2) Read the “Decimal Value” label on page 123. For example, read “1” and “2” for the scanner to re-read the barcode for 12 times. 3) Read the “Validate” label on the same page to complete this setting. 29 Update 1600 Series Barcode Scanner User Guide 30 Enter Setup Chapter 2 SELECTING OUTPUT INTERFACE In order to establish a proper connection between your computer and the scanner, we suggest that you follow these instructions – 1) Install batteries and press the [Delete] key for 3 seconds to turn on the scanner. 2) Have the scanner read the “Enter Setup” label to enter the configuration mode. 3) Have the scanner read the associated label to activate the desired interface. See the following sections for output interfaces supported. 4) Have the scanner read the labels for related settings. 5) Have the scanner read the “Update” label to exit the configuration mode. Note: By default, the output interface is set to “Bluetooth HID”. IN THIS CHAPTER 2.1 Bluetooth HID ........................................................... 31 2.2 Bluetooth SPP ........................................................... 38 2.1 BLUETOOTH HID Refer to Chapter 3 – Setting up Bluetooth Connections for related settings. Bluetooth HID Settings Defaults Keyboard Type PCAT (US) Digits Layout Normal Capital Lock Type Normal Capital Lock State Off Alphabets Transmission Case-sensitive Digits Transmission Alphanumeric keypad Inter-Function Delay 0 (ms) Send “NR” to Host Disable 31 Update 1600 Series Barcode Scanner User Guide 2.1.1 ACTIVATE BLUETOOTH HID & SELECT KEYBOARD TYPE By default, Bluetooth HID is activated on the 1660 scanner, and the keyboard type is set to PCAT (US). When Bluetooth HID is re-activated, you will have to select a keyboard type to complete this setting. Activate Bluetooth HID & Select Keyboard Type … 1) Read the label above to activate Bluetooth HID and select a keyboard type. 2) Read the “Decimal Value” label on page 123. Refer to the table below for the number of desired keyboard type. 3) Read the “Validate” label on the same page to complete this setting. KEYBOARD TYPE By default, the keyboard type is set to PCAT (US). The following keyboard types are supported – No. Keyboard Type No. Keyboard Type 64 PCAT (US) 70 PCAT (UK) 65 PCAT (French) 71 PCAT (Belgium) 66 PCAT (German) 72 PCAT (Spanish) 67 PCAT (Italy) 73 PCAT (Portuguese) 68 PCAT (Swedish) 74 PS55 A01-2 (Japanese) 69 PCAT (Norwegian) 75 User-defined table 2.1.2 RESET CONNECTION For Bluetooth HID, you can only have one scanner connected to your computer. If you want to connect the scanner to another computer, you must have it read the “Reset Connection” label first. The scanner will restart itself automatically. Then, go through the whole process to establish a new connection. Reset Connection 32 Enter Setup Chapter 2 ! Ζ 2.1.3 KEYBOARD SETTINGS Digits Layout Capital Lock Type Capital Lock Setting Alphabets Transmission Digits Transmission Note: Bluetooth HID does not support these functions on PDAs – (1) Capital Lock Setting: Auto Detection (2) Digits Transmission: Numeric Key DIGITS LAYOUT Select a proper layout that matches the alphabets layout. The scanner will make adjustments according to this setting. Options Description Normal Depends on the [Shift] key or [Shift Lock] setting Lower Row For QWERTY and QWERTZ keyboards Upper Row For AZERTY keyboards *Normal Lower Row Upper Row Note: This setting is to be used with the Character Substitution setting when support to certain keyboard types (languages) is unavailable but required. CAPITAL LOCK TYPE & SETTING In order to send the alphabets with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabets being transmitted. 33 Update 1600 Series Barcode Scanner User Guide Cap Lock Type Description Normal Normal type Capital Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys. Shift Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. In addition, this affects the number or punctuation keys. *Normal Capital Lock Shift Lock Capital Lock State Description Capital Lock OFF Assuming that the status of Caps Lock on the keyboard is OFF, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Capital Lock ON Assuming that the status of Caps Lock on the keyboard is ON, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Auto Detection Refer to the Capital Lock Type above. The scanner will automatically detect the status of Caps Lock on the keyboard before data is transmitted; transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). This setting is not supported on PDAs. *Capital Lock OFF 34 Enter Setup Chapter 2 ! Ζ Capital Lock ON Auto Detection ALPHABETS TRANSMISSION By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabets transmitted according to the status of Caps Lock on the keyboard only. 35 Update 1600 Series Barcode Scanner User Guide *Case-sensitive Ignore Case DIGITS TRANSMISSION By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if you wish to use the keys on the numeric keypad. *Alphanumeric Key Numeric Key Note: If you select “Numeric Keypad”, the Num Lock status of the physical keyboard should be "ON". This setting is not supported on PDAs. 2.1.4 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 255, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. 36 Enter Setup Chapter 2 ! Ζ Value Delay Time Value Delay Time Disable 195 ~ 204 200 millisecond 1 ~ 14 10 millisecond 205 ~ 214 210 millisecond 15 ~ 24 20 millisecond 215 ~ 224 220 millisecond 25 ~ 34 30 millisecond 225 ~ 234 230 millisecond 35 ~ 44 40 millisecond 235 ~ 244 240 millisecond 45 ~ 54 50 millisecond 245 ~ 254 250 millisecond … … 255 260 millisecond Inter-Function Delay … (*0 ~ 255) 1) Read the label above to specify the inter-function delay. 2) Read the “Decimal Value” label on page 123 for the desired inter-function delay (millisecond). 3) Read the “Validate” label on the same page to complete this setting. 37 Update 1600 Series Barcode Scanner User Guide 2.2 BLUETOOTH SPP Refer to Chapter 3 – Setting up Bluetooth Connections for related settings. 2.2.1 ACTIVATE BLUETOOTH SPP Activate Bluetooth SPP 2.2.2 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 255, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Value Delay Time Value Delay Time Disable 195 ~ 204 200 millisecond 1 ~ 14 10 millisecond 205 ~ 214 210 millisecond 15 ~ 24 20 millisecond 215 ~ 224 220 millisecond 25 ~ 34 30 millisecond 225 ~ 234 230 millisecond 35 ~ 44 40 millisecond 235 ~ 244 240 millisecond 45 ~ 54 50 millisecond 245 ~ 254 250 millisecond … … 255 260 millisecond Inter-Function Delay … (*0 ~ 255) 1) Read the label above to specify the inter-function delay. 2) Read the “Decimal Value” label on page 123 for the desired inter-function delay (millisecond). 3) Read the “Validate” label on the same page to complete this setting. 38 Enter Setup Chapter 2 ! Ζ 2.2.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data three more times. If all the attempts fail without any notification, data loss will occur. ACK/NAK Time-Out after … (*0 ~ 99) 1) Read the label above to specify the time interval for the scanner to send data and wait for a response from the host. 2) Read the “Decimal Value” label on page 123. For example, read “1” and “0” for the scanner to automatically shut down after being idle for 1 second. 3) Read the “Validate” label on the same page to complete this setting. ACK/NAK ERROR BEEP Enable Error Beep *Disable Error Beep Note: We suggest you to enable the error beep so that you will be notified of such data loss and have the scanner re-read data. 39 Update 1600 Series Barcode Scanner User Guide 40 Enter Setup Chapter 3 SETTING UP BLUETOOTH CONNECTIONS The Bluetooth scanner can be configured to send data to a computer via a Bluetooth dongle, or directly to a Bluetooth-enabled PDA or laptop. Upon powering up, the 1660 scanner will be ready for establishing a Bluetooth connection with a Bluetooth dongle. Below is the procedure to configure the 1660 scanner before establishing a Bluetooth connection. 1) Have the scanner read the “Enter Setup” label to enter the configuration mode. 2) Have the scanner read the desired Bluetooth interface label – “Activate Bluetooth SPP” or “Activate Bluetooth HID & Select Keyboard Type”. It supports PCAT – US, French, German, Italian, Swedish, Norwegian, UK, Belgium, Spanish, Portuguese, and PS55 A01-2 – Japanese. 3) Have the scanner read the labels related to Bluetooth settings, such as Device Name Broadcasting, Authentication & PIN Code, etc. 4) Have the scanner read the “Update” label to exit the configuration mode. Once connected, be aware of the following notifications during operation – When getting out of range or powering off the cradle, the scanner will respond with two short beeps (high-low tone) and its LED indicator will become blue, flashing quickly. The power-saving feature of the scanner will automatically shut down the scanner and stop a Bluetooth connection when it is idle for a specific period of time. The scanner will respond with three beeps (tone descending from high to low) and its LED indicator will become off. IN THIS CHAPTER 3.1 Configuring Bluetooth Settings..................................... 42 3.2 Connecting via Bluetooth Dongle.................................. 44 41 Update 1600 Series Barcode Scanner User Guide 3.1 CONFIGURING BLUETOOTH SETTINGS 3.1.1 SNIFF MODE (POWER-SAVING) This is Bluetooth standard power-saving feature, also known as Sniff mode. When enabled, the scanner will listen to the piconet at a reduced rate. Note: By default, power-saving is enabled. When connecting more than two 1660 scanners via the Bluetooth dongle, we suggest you to disable the power-saving setting for a more reliable connection. *Enable Disable 3.1.2 DEVICE NAME BROADCASTING The scanner can be configured to hide itself from other Bluetooth devices. Simply disable the device name broadcasting setting so that it won’t be discovered by any other computer or PDA. However, broadcasting must be enabled for establishing an initial connection with the scanner. For example, you can disable device name broadcasting after successfully connecting the scanner to WorkStation1. Such connection will be maintained automatically unless the scanner is removed from the paired device list (called unpairing) by WorkStation1 or any changes made to authentication and the PIN code. If you want WorkStation2 to connect to the scanner, you will have to enable device name broadcasting first. Note: By default, device name broadcasting is enabled (which is required for initial connection). *Enable Disable 42 Enter Setup Chapter 3 ! Ζ 3.1.3 AUTHENTICATION For security concerns, it is suggested that you enable authentication and specify a unique PIN code, also known as the passkey used to pair two Bluetooth devices. The scanner itself allows up to 16 characters for a PIN code. This means you will have to enter exactly the same string for your computer or PDA to connect to the scanner. If the passkey is incorrect, any connection attempt will be turned down by the scanner. When any changes are made to authentication and PIN code on the scanner side, you will have to remove the scanner from the paired device list (called unpairing) and go through the whole process to re-establish the connection. Yes *No ENTERING PIN CODE By default, the Bluetooth PIN code is set to “0000”. Maximum 16 characters are allowed. Note: When using Bluetooth HID, some driver of Bluetooth dongle may not support pre-defined PIN code for authentication. In this case, make sure you disable authentication before pairing. The host PIN code will be displayed on the computer screen. Have the scanner read the setup barcode “Enter PIN Code in Decimal” to input the matching PIN code quickly. Enter PIN Code in Hexadecimal … Enter PIN Code in Decimal … 1) Read one of the labels above to specify the PIN code, in decimal or hexadecimal. 2) Read the “Decimal Value” label on page 123 or the “Hexadecimal Value” label on page 124 for the desired digits or character string. 3) Read the “Validate” label on the same page to complete this setting. 43 Update 1600 Series Barcode Scanner User Guide 3.2 CONNECTING VIA BLUETOOTH DONGLE This is called "pairing with a Bluetooth device". The procedure for connecting the scanner to a computer via a Bluetooth dongle is pretty much the same except for the software you are using. Note: When connecting more than two Bluetooth scanners to a computer via the Bluetooth dongle, we suggest you to disable “Sniff Mode” for a more reliable connection. If your computer is running Microsoft Windows XP Service Pack 2 (SP2) or Windows Vista, you can use the generic software support that Windows includes, or you can use the driver that the device manufacturer provides. Now, let’s try using the generic software support that Windows XP Service Pack 2 includes. 3.2.1 BLUETOOTH HID – ADD BLUETOOTH DEVICE WIZARD By default, Bluetooth HID is activated on the 1660 scanner, and the keyboard type is set to PCAT (US). When Bluetooth HID is re-activated, you will have to select a keyboard type to complete this setting. The procedure is the same as for Bluetooth SPP. Refer to steps 1~11 below. 3.2.2 BLUETOOTH SPP – ADD BLUETOOTH DEVICE WIZARD 1) Connect a Bluetooth dongle to your computer, running Windows XP SP2. 2) Double-click the Bluetooth icon fro the lower right of the taskbar. Alternatively, you may go to Control Panel > Bluetooth Devices. 3) Click [Add] to search Bluetooth devices nearby. 4) Select the check box of [My device is set up and ready to be found] when the Bluetooth scanner is ready – having battery inserted or USB cable connected, Bluetooth settings such as select Bluetooth SPP or Bluetooth HID, broadcasting enabled, authentication enabled, and PIN code specified, etc. 5) Click [Next]. 6) Wait for a few seconds for the Wizard to search available Bluetooth devices nearby. The scanner will appear with its “serial number” as the device name. You may double-check the “Serial Number” label on the scanner to ensure connecting with the correct scanner. Select the target scanner. If the target scanner does not appear on the list, click [Search Again] to refresh the list. The scanner might enter Suspend Mode now, and you can press the trigger to have it active again (=discoverable). It will then stay active for one minute and wait for PC to establish a connection. 7) Click [Next]. 44 Enter Setup Chapter 3 ! Ζ 45 Update 1600 Series Barcode Scanner User Guide 8) Enter the passkey for authentication, which must be exactly the same as configured for the scanner. 9) Click [Next]. Wait for a few seconds for Windows to exchange passkeys. 10) Click [Finish]. Ignore this 46 Enter Setup Chapter 3 ! Ζ Bluetooth SPP Only 10 11) Now the target scanner will be listed as shown below. For Bluetooth SPP, you can have up to seven scanners connected to your computer. It is possible for another computer to connect to one these scanners as long as it is in Suspend Mode and the authentication and PIN code settings are matching. 47 Update 1600 Series Barcode Scanner User Guide Select and Remove Note: When any changes are made to authentication and PIN code on the scanner side, or you want to change to use Bluetooth HID, it is suggested that you remove the scanner from the paired device list (called unpairing) and go through the whole process to re-establish the connection. 12) Run the desired application, such as HyperTerminal, on your computer. The status of the scanner listed on the device list will be updated to “Connected”, indicating the Bluetooth connection is established successfully via the outgoing COM port. 48 Enter Setup Chapter 3 ! Ζ Bluetooth Connected Bluetooth Disconnected 49 Update 1600 Series Barcode Scanner User Guide 50 Enter Setup Chapter 4 CHANGING SYMBOLOGY SETTINGS In this chapter, a brief on the symbology settings is provided for your reference. IN THIS CHAPTER 4.1 Codabar ................................................................... 4.2 Code 25 - Industrial 25............................................... 4.3 Code 25 - Interleaved 25 ............................................ 4.4 Code 25 - Matrix 25 ................................................... 4.5 Code 39 ................................................................... 4.6 Code 93 ................................................................... 4.7 Code 128.................................................................. 4.8 EAN-8 ...................................................................... 4.9 EAN-13 .................................................................... 4.10 EAN-128 ................................................................. 4.11 ISBT 128 ................................................................ 4.12 MSI........................................................................ 4.13 French Pharmacode .................................................. 4.14 Italian Pharmacode .................................................. 4.15 Plessey ................................................................... 4.16 RSS Family ............................................................. 4.17 Telepen .................................................................. 4.18 UPC-A .................................................................... 4.19 UPC-E .................................................................... 52 54 57 60 63 65 65 66 68 70 71 72 75 76 77 78 82 83 85 51 Update 1600 Series Barcode Scanner User Guide 4.1 CODABAR *Enable Codabar Disable Codabar 4.1.1 START/STOP CHARACTERS SELECTION Select one of the four different start/stop character pairs – * abcd/abcd abcd/tn*e ABCD/ABCD ABCD/TN*E 4.1.2 START/STOP TRANSMISSION Decide whether or not to include the start/stop characters in the data being transmitted. Transmit Codabar Start/Stop Characters 52 Enter Setup Chapter 4 ! Ζ *Do Not Transmit 4.1.3 CLSI CONVERSION When enabled, the CLSI editing strips the start/stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar barcode. Apply CLSI Editing *Do Not Apply Note: The 14-character barcode length does not include start/stop characters. 53 Update 1600 Series Barcode Scanner User Guide 4.2 CODE 25 – INDUSTRIAL 25 *Enable Industrial 25 Disable Industrial 25 4.2.1 START/STOP PATTERN SELECTION This decides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 2 of 5 barcode but with Interleaved 2 of 5 start/stop pattern. In order to read this barcode, the start/stop pattern selection parameter of Industrial 2 of 5 should set to "Interleaved 25". *Industrial 25 Start/Stop Pattern Interleaved 25 Start/Stop Pattern Matrix 25 Start/Stop Pattern 4.2.2 CHECKSUM VERIFICATION Decide whether to verify the checksum. If the checksum is incorrect, the barcode will not be accepted. Verify Industrial 25 Checksum 54 Enter Setup Chapter 4 ! Ζ *Do Not Verify 4.2.3 CHECKSUM TRANSMISSION Decide whether to include the checksum in the data being transmitted. *Transmit Industrial 25 Checksum Do Not Transmit 4.2.4 CODE LENGTH QUALIFICATION Because of the weak structure of the 2 of 5 symbologies, it is possible to make a "short scan" error. To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If “Fixed Length” is selected, up to 2 fixed lengths can be specified. 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. *Enable Max./Min. Length (0 ~ 127) … Enable Fixed Length(s) … 55 Update 1600 Series Barcode Scanner User Guide 2) Read the labels for Max. /Min or fixed length separately. Max. Length (*127) Or Fixed Length 1 Min. Length (*4) Or Fixed Length 2 3) Read the “Decimal Value” label on page 123 for the desired length. 4) Read the “Validate” label on the same page to complete this setting. 56 Enter Setup Chapter 4 ! Ζ 4.3 CODE 25 – INTERLEAVED 25 *Enable Interleaved 25 Disable Interleaved 25 4.3.1 START/STOP PATTERN SELECTION This decides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 2 of 5 barcode but with Interleaved 2 of 5 start/stop pattern. In order to read this barcode, the start/stop pattern selection parameter of Industrial 2 of 5 should set to "Interleaved 25". Industrial 25 Start/Stop Pattern *Interleaved 25 Start/Stop Pattern Matrix 25 Start/Stop Pattern 4.3.2 CHECKSUM VERIFICATION Decide whether to verify the checksum. If the checksum is incorrect, the barcode will not be accepted. Verify Interleaved 25 Checksum 57 Update 1600 Series Barcode Scanner User Guide *Do Not Verify 4.3.3 CHECKSUM TRANSMISSION Decide whether to include the checksum in the data being transmitted. *Transmit Interleaved 25 Checksum Do Not Transmit 4.3.4 CODE LENGTH QUALIFICATION Because of the weak structure of the 2 of 5 symbologies, it is possible to make a "short scan" error. To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If “Fixed Length” is selected, up to 2 fixed lengths can be specified. 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. *Enable Max./Min. Length (0 ~ 127) … 58 Enter Setup Chapter 4 ! Ζ Enable Fixed Length(s) … 2) Read the labels for Max. /Min or fixed length separately. Max. Length (*126) Or Fixed Length 1 Min. Length (*4) Or Fixed Length 2 3) Read the “Decimal Value” label on page 123 for the desired length. 4) Read the “Validate” label on the same page to complete this setting. 59 Update 1600 Series Barcode Scanner User Guide 4.4 CODE 25 – MATRIX 25 Enable Matrix 25 *Disable Matrix 25 4.4.1 START/STOP PATTERN SELECTION This decides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 2 of 5 barcode but with Interleaved 2 of 5 start/stop pattern. In order to read this barcode, the start/stop pattern selection parameter of Industrial 2 of 5 should set to "Interleaved 25". Industrial 25 Start/Stop Pattern Interleaved 25 Start/Stop Pattern *Matrix 25 Start/Stop Pattern 4.4.2 CHECKSUM VERIFICATION Decide whether to verify the checksum. If the checksum is incorrect, the barcode will not be accepted. Verify Matrix 25 Checksum 60 Enter Setup Chapter 4 ! Ζ *Do Not Verify 4.4.3 CHECKSUM TRANSMISSION Decide whether to include the checksum in the data being transmitted. *Transmit Matrix 25 Checksum Do Not Transmit 4.4.4 CODE LENGTH QUALIFICATION Because of the weak structure of the 2 of 5 symbologies, it is possible to make a "short scan" error. To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If “Fixed Length” is selected, up to 2 fixed lengths can be specified. 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. *Enable Max./Min. Length (0 ~ 127) … 61 Update 1600 Series Barcode Scanner User Guide Enable Fixed Length(s) … 2) Read the labels for Max. /Min or fixed length separately. Max. Length (*127) Or Fixed Length 1 Min. Length (*4) Or Fixed Length 2 3) Read the “Decimal Value” label on page 123 for the desired length. 4) Read the “Validate” label on the same page to complete this setting. 62 Enter Setup Chapter 4 ! Ζ 4.5 CODE 39 *Enable Code 39 Disable Code 39 4.5.1 START/STOP TRANSMISSION Decide whether or not to include the start/stop characters in the data being transmitted. Transmit Code 39 Start/Stop Characters *Do Not Transmit 4.5.2 CHECKSUM VERIFICATION Decide whether or not to perform checksum verification when decoding barcodes. If enabled and the checksum found incorrect, the barcode will not be accepted. Verify Code 39 Checksum *Do Not Verify 63 Update 1600 Series Barcode Scanner User Guide 4.5.3 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted. *Transmit Code 39 Checksum Do Not Transmit 4.5.4 STANDARD/FULL ASCII CODE 39 Decide whether or not to support Code 39 Full ASCII that includes all the alphanumeric and special characters. Code 39 Full ASCII *Standard Code 39 64 Enter Setup Chapter 4 ! Ζ 4.6 CODE 93 You can only configure the scanner to read this symbology or not. *Enable Code 93 Disable Code 93 4.7 CODE 128 You can only configure the scanner to read this symbology or not. *Enable Code 128 Disable Code 128 65 Update 1600 Series Barcode Scanner User Guide 4.8 EAN-8 *Enable EAN-8 (No Addon) Disable EAN-8 (No Addon) Enable EAN-8 Addon 2 *Disable EAN-8 Addon 2 Enable EAN-8 Addon 5 *Disable EAN-8 Addon 5 4.8.1 CONVERT TO EAN-13 Decide whether or not to expand the read EAN-8 barcode into EAN-13. If enabled, the next processing will follow the parameters configured for EAN-13. Convert EAN-8 to EAN-13 66 Enter Setup Chapter 4 ! Ζ *Do Not Convert 4.8.2 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted. *Transmit EAN-8 Checksum Do Not Transmit 67 Update 1600 Series Barcode Scanner User Guide 4.9 EAN-13 *Enable EAN-13 (No Addon) Disable EAN-13 (No Addon) Enable EAN-13 Addon 2 *Disable EAN-13 Addon 2 Enable EAN-13 Addon 5 *Disable EAN-13 Addon 5 4.9.1 ISBN CONVERSION Decide whether or not to convert the EAN-13 barcode, starting with 978 and 979, to ISBN. Convert EAN-13 to ISBN 68 Enter Setup Chapter 4 ! Ζ *Do Not Convert 4.9.2 ISSN CONVERSION Decide whether or not to convert the EAN-13 barcode, starting with 977 to ISSN. Convert EAN-13 to ISSN *Do Not Convert 4.9.3 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted. *Transmit EAN-13 Checksum Do Not Transmit 69 Update 1600 Series Barcode Scanner User Guide 4.10 EAN-128 Enable EAN-128 *Disable EAN-128 4.10.1 CODE ID TRANSMISSION Decide whether or not to include the Code ID (“]C1”) in the data being transmitted. Transmit EAN-128 Code ID *Do Not Transmit 4.10.2 FIELD SEPARATOR (GS CHARACTER) Decide whether or not to apply a field separator (to convert the FNC1 control character to human readable character). Enable Field Separator … 1) Read the label above to enable field separator. 2) Read the “Hexadecimal Value” label on page 124 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. 70 Enter Setup Chapter 4 ! Ζ Note: EAN-128 barcodes start with the FNC1 control character to distinguish themselves from other uses of Code 128. FNC1 is also used to separate data fields in the EAN-128 barcodes. 4.11 ISBT 128 You can only configure the scanner to read this symbology or not. Enable ISBT 128 *Disable ISBT 128 71 Update 1600 Series Barcode Scanner User Guide 4.12 MSI Enable MSI *Disable MSI 4.12.1 CHECKSUM VERIFICATION Select one of the three checksum calculations to perform checksum verification when decoding barcodes. If enabled and the checksum found incorrect, the barcode will not be accepted. *Single Modulo 10 Double Modulo 10 Modulo 10 & 11 4.12.2 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted. *Last Digit Not Transmitted 72 Enter Setup Chapter 4 ! Ζ Both Digits Transmitted Both Digits Not Transmitted 4.12.3 CODE LENGTH QUALIFICATION Because of the weak structure of the symbology, it is possible to make a "short scan" error. To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If “Fixed Length” is selected, up to 2 fixed lengths can be specified. 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. *Enable Max./Min. Length (0 ~ 127) … Enable Fixed Length(s) … 2) Read the labels for Max. /Min or fixed length separately. Max. Length (*127) Or Fixed Length 1 Min. Length (*4) Or Fixed Length 2 73 Update 1600 Series Barcode Scanner User Guide 3) Read the “Decimal Value” label on page 123 for the desired length. 4) Read the “Validate” label on the same page to complete this setting. 74 Enter Setup Chapter 4 ! Ζ 4.13 FRENCH PHARMACODE Enable French Pharmacode *Disable French Pharmacode 4.13.1 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted. *Transmit French Pharmacode Checksum Do Not Transmit 75 Update 1600 Series Barcode Scanner User Guide 4.14 ITALIAN PHARMACODE Enable Italian Pharmacode *Disable Italian Pharmacode 4.14.1 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted. *Transmit Italian Pharmacode Checksum Do Not Transmit 76 Enter Setup Chapter 4 ! Ζ 4.15 PLESSEY Enable Plessey *Disable Plessey 4.15.1 CONVERT TO UK PLESSEY Decide whether or not to change each occurrence of the character 'A' to character 'X' in the decoded data. Convert to UK Plessey *Do Not Convert 4.15.2 CHECKSUM TRANSMISSION Decide whether or not to include the checksum characters (two digits) in the data being transmitted. *Transmit Plessey Checksum Do Not Transmit 77 Update 1600 Series Barcode Scanner User Guide 4.16 RSS FAMILY 4.16.1 CODE ID SELECTION Select a desired Code ID to use – RSS Code ID “]e0“ or EAN-128 Code ID “]C1”. “]C1” for RSS Code ID “]e0” for RSS Code ID (Default) 4.16.2 RSS-14 Enable RSS-14 & RSS Expanded *Disable RSS-14 & RSS Expanded CODE ID TRANSMISSION Decide whether or not to include the Code ID in the data being transmitted. *Transmit RSS-14 Code ID Do Not Transmit 78 Enter Setup Chapter 4 ! Ζ APPLICATION ID TRANSMISSION Decide whether or not to include the Application ID ("01") in the data being transmitted. *Transmit RSS-14 Application ID Do Not Transmit CHECKSUM TRANSMISSION Decide whether or not to include the check digit in the data being transmitted. *Transmit RSS-14 Checksum Do Not Transmit 4.16.3 RSS EXPANDED Enable RSS-14 & RSS Expanded *Disable RSS-14 & RSS Expanded CODE ID TRANSMISSION Decide whether or not to include the Code ID in the data being transmitted. 79 Update 1600 Series Barcode Scanner User Guide *Transmit RSS Expanded Code ID Do Not Transmit 4.16.4 RSS LIMITED Enable RSS Limited *Disable RSS Limited CODE ID TRANSMISSION Decide whether or not to include the Code ID in the data being transmitted. *Transmit RSS Limited Code ID Do Not Transmit APPLICATION ID TRANSMISSION Decide whether or not to include the Application ID ("01") in the data being transmitted. 80 Enter Setup Chapter 4 ! Ζ *Transmit RSS Limited Application ID Do Not Transmit CHECKSUM TRANSMISSION Decide whether or not to include the check digit in the data being transmitted. *Transmit RSS Limited Checksum Do Not Transmit 81 Update 1600 Series Barcode Scanner User Guide 4.17 TELEPEN Enable Telepen *Disable Telepen 4.17.1 TELEPEN OUTPUT – FULL ASCII/NUMERIC Decide whether or not to support Telepen in full ASCII code. By default, it supports ASCII mode. AIM Telepen (Full ASCII) includes all the alphanumeric and special characters. Original Telepen (Numeric) * AIM Telepen 82 Enter Setup Chapter 4 ! Ζ 4.18 UPC-A *Enable UPC-A (No Addon) Disable UPC-A (No Addon) Enable UPC-A Addon 2 *Disable UPC-A Addon 2 Enable UPC-A Addon 5 *Disable UPC-A Addon 5 4.18.1 CONVERT TO EAN-13 Decide whether or not to expand the read UPC-A barcode into EAN-13. If enabled, the next processing will follow the parameters configured for EAN-13. Convert UPC-A to EAN-13 83 Update 1600 Series Barcode Scanner User Guide *Do Not Convert 4.18.2 SYSTEM NUMBER TRANSMISSION Decide whether or not to include the system number in the data being transmitted. *Transmit UPC-A System Number Do Not Transmit 4.18.3 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted. *Transmit UPC-A Checksum Do Not Transmit 84 Enter Setup Chapter 4 ! Ζ 4.19 UPC-E *Enable UPC-E (No Addon) Disable UPC-E (No Addon) Enable UPC-E Addon 2 *Disable UPC-E Addon 2 Enable UPC-E Addon 5 *Disable UPC-E Addon 5 4.19.1 SYSTEM NUMBER SELECTION Decide whether to decode the ordinary UPC-E barcodes only or both UPC-E0 and UPC-E1 barcodes. System number 0 enabled for decoding UPC-E0 barcodes. System number 1 enabled for decoding UPC-E1 barcodes. System Number 0 & 1 85 Update 1600 Series Barcode Scanner User Guide * System Number 0 Only Warning: Because of the way system number 1 is encoded, if both system numbers are enabled, the user might suffer from short scanning UPC-A or EAN-13 barcodes into UPC-E1 barcodes. 4.19.2 CONVERT TO UPC-A Decide whether or not to expand the read UPC-E barcode into UPC-A. If enable, the next processing will follow the parameters configured for UPC-A. Convert UPC-E to UPC-A *Do Not Convert 4.19.3 SYSTEM NUMBER TRANSMISSION Decide whether or not to include the system number in the data being transmitted. Transmit UPC-E System Number *Do Not Transmit 4.19.4 CHECKSUM TRANSMISSION Decide whether or not to include the checksum character in the data being transmitted. 86 Enter Setup Chapter 4 ! Ζ *Transmit UPC-E Checksum Do Not Transmit 87 Update 1600 Series Barcode Scanner User Guide 88 Enter Setup Chapter 5 DEFINING OUTPUT FORMAT You may configure in which format the collected data will be output to the host computer. Barcode read by the scanner will be processed in the following sequence – 1) Perform character substitution on the data scanned. 2) Add Code ID and Length Code to the front of the data: [Code ID][Length Code][Data] 3) Process the whole data in step 2 with user formats. Data is now divided into fields by user specified rules. 4) Add Prefix Code and Suffix Code before transmission: [Prefix Code][Processed Data][Suffix Code] IN THIS CHAPTER 5.1 5.2 5.3 5.4 5.5 5.6 Letter Case ............................................................... 89 Character Substitution ................................................ 90 Prefix/Suffix Code ...................................................... 96 Code ID.................................................................... 97 Length Code ............................................................101 Multi-Barcode Editor..................................................104 5.1 LETTER CASE By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case. Ignoring the original letter case, select [Upper Case] to output data in upper case only; otherwise, select [Lower Case] to output data in lower case only. *Normal Upper Case Lower Case 89 Update 1600 Series Barcode Scanner User Guide 5.2 CHARACTER SUBSTITUTION Character substitution is performed on every occurrence of the first character specified. If only one character is specified, every occurrence of that character in the barcode will be taken away. The first character will be replaced by the second character(s). Up to three sets of character substitution can be configured. Note: The character substitution is performed only on the barcode itself and before the processing of editing formats. It is not applicable to the Prefix/Suffix Code, Code ID, Length Code, or any Additional Field. 5.2.1 SELECT A SET FOR CHARACTER SUBSTITUION Configure Set 1 Configure Set 2 Configure Set 3 1) Read the label above to enable character substitution by set. For example, have the scanner read the “Set 1” label to configure the first set of character substitution. The scanner will respond with one short beep, high tone, to indicate more setup labels are required. 2) Read the “Hexadecimal Value” label on page 124 for the desired character string. For example, have the scanner read (1) “3”, “0”, “2” and “D” to replace the character [0] with a dash [-] for Set 1, and (2) “3”, “0”, “2”, “D”, “3” and “0”to replace the character [0] with a dash [- 0] for Set 2. 3) Read the “Validate” label on the same page to complete this setting. (The defined set or sets will be applied to all symbologies by default.) 90 Enter Setup Chapter 5 ! Ζ 5.2.2 SYMBOLOGIES FOR CHARACTER SUBSTITUTION (ALL 3 SETS) By default character substitution will be performed on all symbologies. If the character substitution is not desired with one or more symbologies, read the “Ignore” label for each undesired symbologies and all the three sets will not be applied to them. CODABAR *Apply to Codabar Do Not Apply CODE 39 Do Not Apply *Apply to Code 39 CODE 93 *Apply to Code 93 Do Not Apply CODE 128 *Apply to Code 128 Do Not Apply EAN-128 *Apply to EAN-128 Do Not Apply 91 Update 1600 Series Barcode Scanner User Guide EAN-8 (NO ADDON) *Apply to EAN-8 Do Not Apply EAN-8 ADDON 2 *Apply to EAN-8 Addon 2 Do Not Apply EAN-8 ADDON 5 *Apply to EAN-8 Addon 5 Do Not Apply EAN-13 (NO ADDON) *Apply to EAN-13 Do Not Apply EAN-13 ADDON 2 *Apply to EAN-13 Addon 2 Do Not Apply EAN-13 ADDON 5 *Apply to EAN-13 Addon 5 Do Not Apply 92 Enter Setup Chapter 5 ! Ζ FRENCH PHARMACODE *Apply to French Pharmacode Do Not Apply ITALIAN PHARMACODE *Apply to Italian Pharmacode Do Not Apply INDUSTRIAL 25 *Apply to Industrial 25 Do Not Apply INTERLEAVED 25 *Apply to Interleaved 25 Do Not Apply MATRIX 25 *Apply to Matrix 25 Do Not Apply MSI Do Not Apply *Apply to MSI 93 Update 1600 Series Barcode Scanner User Guide PLESSEY *Apply to Plessey Do Not Apply RSS FAMILY *Apply to RSS Family Do Not Apply TELEPEN *Apply to Telepen Do Not Apply UPC-A (NO ADDON) *Apply to UPC-A Do Not Apply UPC-A ADDON 2 *Apply to UPC-A Addon 2 Do Not Apply UPC-A ADDON 5 *Apply to UPC-A Addon 5 Do Not Apply 94 Enter Setup Chapter 5 ! Ζ UPC-E (NO ADDON) *Apply to UPC-E Do Not Apply UPC-E ADDON 2 *Apply to UPC-E Addon 2 Do Not Apply UPC-E ADDON 5 *Apply to UPC-E Addon 5 Do Not Apply 95 Update 1600 Series Barcode Scanner User Guide 5.3 PREFIX/SUFFIX CODE By default, there is no prefix code, and [ENTER] or [CR] (Carriage Return) is configured to be suffix code. Up to 8 characters can be configured, for example, “Barcode_”, and you will have the string appear in front of the barcode read, like this – “Barcode_1234567890”. If “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type. Key Status Key Type Scan Code Up to 4 scan code values are allowed – each requires two hexadecimal values. N/A Normal Key Up to 8 character strings are allowed – each requires two hexadecimal values. Default setting Add Shift Add Left Ctrl Add Left Alt Add Right Ctrl Add Right Alt Add Break For example, read labels for [Add Shift], [A], [Add Shift], and [B]. Configure Prefix Configure Suffix 1) Read the label above to apply prefix code or suffix code separately. (Max. 8 characters each) 2) Read the “Hexadecimal Value” label on page 124 for the desired character string. For example, read “2” and “B” for the scanner to prefix or suffix the character [+]. 3) Read the “Validate” label on the same page to complete this setting. 96 Enter Setup Chapter 5 ! Ζ 5.4 CODE ID Up to two characters for Code ID can be configured for each symbology. To make the Code ID configuration easier, the scanner provides five pre-defined Code ID sets that you can select one and make necessary changes on it. If "Keyboard Wedge" is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type. Key Status Key Type Scan Code Up to 1 scan code values are allowed – each requires two hexadecimal values. N/A Normal Key Up to 2 character strings are allowed – each requires two hexadecimal values. Default setting Add Shift Add Left Ctrl Add Left Alt Add Right Ctrl Add Right Alt Add Break For example, read labels for [Add Shift] and the character [A]. Note: "]C1" is the Code ID of EAN-128 barcodes; "]e0" is the default Code ID of RSS barcodes. 5.4.1 SELECT PRE-DEFINED CODE ID Code ID options Set 1 Set 2 Set 3 Set 4 Set 5 Code 39 Italian Pharmacode French Pharmacode Industrial 25 Interleaved 25 Matrix 25 97 Update 1600 Series Barcode Scanner User Guide Codabar Code 93 Code 128 UPC-E EAN-8 FF EAN-13 UPC-A MSI Plessey Telepen --- --- --- --- Apply Code ID Set 1 Apply Code ID Set 2 Apply Code ID Set 3 Apply Code ID Set 4 Apply Code ID Set 5 5.4.2 CHANGE CODE ID 1) Read the label of a specific symbology below to change its code ID. 2) Read the “Hexadecimal Value” label on page 124 for the desired character string. For example, read “4” and “4” for applying the character [D] for Code ID. 3) Read the “Validate” label on the same page to complete this setting. 98 Enter Setup Chapter 5 ! Ζ Configure Code ID for Codabar Configure Code ID for Code 39 Configure Code ID for Code 93 Configure Code ID for Code 128 Configure Code ID for EAN-8 Configure Code ID for EAN-13 Configure Code ID for French Pharmacode Configure Code ID for Italian Pharmacode Configure Code ID for Industrial 25 Configure Code ID for Interleaved 25 99 Update 1600 Series Barcode Scanner User Guide Configure Code ID for Matrix 25 Configure Code ID for MSI Configure Code ID for Plessey Configure Code ID for Telepen Configure Code ID for UPC-A Configure Code ID for UPC-E 5.4.3 CLEAR CODE ID SETTINGS Clear All Code ID Settings 100 Enter Setup Chapter 5 ! Ζ 5.5 LENGTH CODE A two-digit code representing the length of barcode data (character count) can be inserted in front of data being transmitted. Such "Length" code can be individually enabled or disabled for each symbology. CODABAR Apply to Codabar *Do Not Apply CODE 39 Apply to Code 39 *Do Not Apply CODE 93 Apply to Code 93 *Do Not Apply CODE 128 Apply to Code 128 *Do Not Apply EAN-128 & RSS Apply to EAN-128 & RSS *Do Not Apply EAN-8 Apply to EAN-8 *Do Not Apply 101 Update 1600 Series Barcode Scanner User Guide EAN-13 Apply to EAN-13 *Do Not Apply FRENCH PHARMACODE Apply to French Pharmacode *Do Not Apply ITALIAN PHARMACODE Apply to Italian Pharmacode *Do Not Apply INDUSTRIAL 25 Apply to Industrial 25 *Do Not Apply INTERLEAVED 25 Apply to Interleaved 25 *Do Not Apply MATRIX 25 Apply to Matrix 25 *Do Not Apply MSI Apply to MSI *Do Not Apply 102 Enter Setup Chapter 5 ! Ζ PLESSEY Apply to Plessey *Do Not Apply TELEPEN Apply to Telepen *Do Not Apply UPC-A Apply to UPC-A *Do Not Apply UPC-E Apply to UPC-E *Do Not Apply 103 Update 1600 Series Barcode Scanner User Guide 5.6 MULTI-BARCODE EDITOR The Multi-Barcode Editor allows you to decide the output sequence of a concatenation of barcodes. Note: Multi-Barcode Editor cannot work with “Multi-Barcode Mode”. The barcodes that are found meeting the specified criteria below will be arranged in the desired sequence. Code Type 4-digit code length, including prefix, suffix, length code, etc. Matching the first character of data 104 Enter Setup Chapter 5 ! Ζ 5.6.1 EDIT A CONCATENATION OF BARCODES Edit Output Sequence 1) Read the label above to start editing a concatenation of barcodes. 2) Code Type setting – read the “Hexadecimal Value” label on page 124 for Code Type of the (first) barcode. For example, read “4” and “1” for Code 39. Code Type Symbology Code Type Symbology 41 (A) Code 39 4F (O) EAN-8 with Addon 5 42 (B) Italian Pharmacode 50 (P) EAN-13 43 (C) French Pharmacode) 51 (Q) EAN-13 with Addon 2 44 (D) Industrial 25 52 (R) EAN-13 with Addon 5 45 (E) Interleaved 25 53 (S) MSI 46 (F) Matrix 25 54 (T) Plessey 47 (G) Codabar (NW7) 55 (U) EAN-128 48 (H) Code 93 56 (V) UPC-A 49 (I) Code 128 57 (W) UPC-A with Addon 2 4A (J) UPC-E0 / UPC-E1 58 (X) UPC-A with Addon 5 4B (K) UPC-E with Addon 2 4C (L) UPC-E with Addon 5 5A (Z) Telepen 4D (M) EAN-8 5B ( [ ) RSS-14 4E (N) EAN-8 with Addon 2 3) Code Length setting – read the “Decimal Value” label on page 123 for the 4-digit total length of the (first) barcode. For example, read 0065 for 65 characters or read “0000” for any length. Note: If not reading 0000 for any length, the 4-digit length must include prefix, suffix (0x0d by default), length code, etc. 4) Matching Character setting – read the “Hexadecimal Value” label on page 124 for the 1st character that must be found matching in the (first) barcode. For example, read “4” and “1” for matching character “A” as the first character in the barcode or read “00” for any character. 5) Read twice the “F” label on page 124 (“FF”) to complete the setting of each barcode. 6) Read the label “Validate” to end the editing of the barcode set. 105 Update 1600 Series Barcode Scanner User Guide 5.6.2 ACTIVATE THE CONCATENATION OF BARCODES By default, the output sequence editing of the concatenation of barcodes is not applied. When “Enforce Output Sequence” is enabled, all barcodes read by the scanner must meet with the criteria for the concatenation. If data is found excluded from all output sequence sets (= not meeting with the criteria), the scanner will not accept the reading, and therefore, data will not be transmitted. When “Apply Output Sequence” is enabled, only barcodes found meeting with the criteria are counted for the concatenation. Those found not meeting with the criteria are processed normally and individually. *Ignore Output Sequence Enforce Output Sequence Apply Output Sequence 106 Enter Setup Chapter 6 APPLYING FORMATS FOR DATA EDITING The scanner allows advanced data editing by applying user-configured editing formats. Data is divided into fields by user-specified rules. These fields together with the user-configurable additional fields consist of the data actually sent to the host computer. IN THIS CHAPTER 6.1 Format Selection ......................................................108 6.2 Editing Format..........................................................110 6.3 Programming Examples .............................................123 107 Update 1600 Series Barcode Scanner User Guide 6.1 FORMAT SELECTION 6.1.1 ACTIVATE EDITING FORMATS If you have already configured any editing format before, you may directly apply the editing format. If not, you must start with configuring an editing format first, and then, activate the editing format when it is desired in use. EDITING FORMAT 1 Enable Format 1 *Disable Format 1 EDITING FORMAT 2 Enable Format 2 *Disable Format 2 EDITING FORMAT 3 Enable Format 3 *Disable Format 3 108 End Programming Format Chapter 6 ! Ζ EDITING FORMAT 4 Enable Format 4 *Disable Format 4 EDITING FORMAT 5 Enable Format 5 *Disable Format 5 6.1.2 EXCLUSIVE DATA EDITING By default, only barcodes found meeting with the criteria are processed by the editing formats. Those found not meeting with the criteria are processed normally. When “Exclusive Data Editing” is enabled, all barcodes read by the scanner must be processed by the editing formats. If data is found excluded from all enabled editing formats (= not meeting with the specified criteria), the scanner will not accept the reading, and therefore, data will not be transmitted. Yes *No 109 Update 1600 Series Barcode Scanner User Guide 6.2 EDITING FORMAT 6.2.1 SELECT FORMAT TO CONFIGURE START PROGRAMMING FORMAT Select one editing format (Format 1~5) and the parameters pertaining to the editing format can then be configured – applicable code type, data length, matching string & location, total number of fields, field settings (field-dividing rule), additional fields, and field transmission sequence. Up to five different formats can be specified. Configure Format 1 110 End Programming Format Chapter 6 ! Ζ Configure Format 2 Configure Format 3 Configure Format 4 Configure Format 5 Note: Before you complete the programming of an editing format, if you have the scanner read any label for parameters other than those pertaining to the editing format, it will automatically abort the programming process. END PROGRAMMING FORMAT After having configured all the desired parameters, you must have the scanner read the “End Programming Format” label, which can be located at the bottom of every even page in this chapter. End Programming Format 6.2.2 RESTORE DEFAULT FORMAT You may select an existing editing format and have the defaults restored. The default settings of an editing format are listed below. Editing format Defaults Applicable Code Type All Data Length 0 (No qualification.) Matching String Disable Matching String Location None 111 Update 1600 Series Barcode Scanner User Guide Total Number of Fields Field Setting – field-dividing rule Not configured. Additional Fields None Field Transmission Sequence F1 Restore Default Format 6.2.3 DEFINE DATA CRITERIA Three applicable conditions can be configured to check whether the data read by the scanner can be processed by the particular editing format. Note: Data editing cannot be performed unless the three conditions are all met. APPLICABLE CODE TYPE By default, barcodes of all the supported symbologies will be processed by any editing format, if having been configured and enabled. *Apply to All Code Types Clear All Codabar Applicable Code 39 Applicable Code 93 Applicable Code 128 Applicable EAN-8 Applicable EAN-8 Addon 2 Applicable 112 End Programming Format Chapter 6 ! Ζ EAN-8 Addon 5 Applicable EAN-13 Applicable EAN-13 Addon 2 Applicable EAN-13 Addon 5 Applicable EAN-128 & RSS Applicable French Pharmacode Applicable Italian Pharmacode Applicable Industrial 25 Applicable Matrix 25 Applicable Interleaved 25 Applicable MSI Applicable Plessey Applicable Telepen Applicable UPC-A Applicable UPC-A Addon 2 Applicable UPC-A Addon 5 Applicable 113 Update 1600 Series Barcode Scanner User Guide UPC-E Applicable UPC-E Addon 2 Applicable UPC-E Addon 5 Applicable DATA LENGTH By default, barcodes of any length (character count) are eligible for data editing. You may specify a value from 0 to 255. When zero is given to both, the scanner will not perform the length qualification. 1) Read the labels for Max. /Min length separately. Max. Length Min. Length 2) Read the “Decimal Value” label on page 123 for the desired length. 3) Read the “Validate” label on the same page to complete this setting. MATCHING STRING & LOCATION By default, no matching string is specified, and therefore, it is disabled. You may enable this feature by specifying a matching string; up to four characters are allowed. When the Matching String Location is zero, the scanner will only check for the existence of the matching string in the barcode data. You may specify a value from 1 to 255 to indicate where the matching string starts in the barcode data. 114 End Programming Format Chapter 6 ! Ζ 1) Read the label to specify a matching string. Matching String … 2) Read the “Hexadecimal Value” label on page 124 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. 4) Read the label to specify the location of the matching string. Location of Matching String … 5) Read the “Decimal Value” label on page 123 for the desired location. 6) Read the “Validate” label on the same page to complete this setting. 6.2.4 DIVIDE DATA INTO FIELDS START POSITION Data can be divided into fields in one of the following direction – from head (F1) to tail (F5) from tail (F1) to head (F5) *From Head From Tail FIELD ADJUSTMENT You may apply equal length to all fields, if necessary. It will add “Space” (0x20) to field when data is found shorter than specified. 115 Update 1600 Series Barcode Scanner User Guide *No Adjustment Set Length to adjust fields … (*0) 1) Read the label above to adjust field by length. 2) Read the “Decimal Value” label on page 123 for the desired field length. 3) Read the “Validate” label on the same page to complete this setting. TOTAL NUMBER OF FIELDS Data can be divided into at most 6 fields; each of them is numbered from F1 to F6 accordingly. However, only F1~F5 can be configured. The total number of fields must be specified correctly. If three fields are configured for the editing format, the data characters after F3 will be assigned to F4 automatically. This feature is quite useful especially when data of variable lengths is processed by editing formats. *One Field Two Fields Three Fields Four Fields Five Fields 116 End Programming Format Chapter 6 ! Ζ Six Fields Note: The number of configurable fields is always one less than the total number of fields specified. The extra data characters beyond the last field configured will be automatically assigned to the next field. 6.2.5 FIELD SETTINGS Data eligible for editing formats is divided into fields by user-specified rules – either using the field terminating string or specified field length. By Terminating String Specify the field terminating string. Up to two characters are allowed. The scanner will search for the occurrence of this particular string in the data. By default, this string will be included in the field. You may discard it. By Length Alternatively, you may simply specify the field length. The scanner will assign the next specified number of characters into the field. FIELD 1 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 124 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. Select Field Separator to Divide Field 1 … Discard Separator *Include Separator 1) Read the label to divide field by length. 2) Read the “Decimal Value” label on page 123 for the desired field length. 3) Read the “Validate” label on the same page to complete this setting. 117 Update 1600 Series Barcode Scanner User Guide Divide Field 1 by Length … FIELD 2 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 124 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. Select Field Separator to Divide Field 2 … *Include Separator Discard Separator 1) Read the label to divide field by length. 2) Read the “Decimal Value” label on page 123 for the desired field length. 3) Read the “Validate” label on the same page to complete this setting. Divide Field 2 by Length … FIELD 3 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 124 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. Select Field Separator to Divide Field 3 … 118 End Programming Format Chapter 6 ! Ζ *Include Separator Discard Separator 1) Read the label to divide field by length. 2) Read the “Decimal Value” label on page 123 for the desired field length. 3) Read the “Validate” label on the same page to complete this setting. Divide Field 3 by Length … FIELD 4 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 124 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. Select Field Separator to Divide Field 4 … Discard Separator *Include Separator 1) Read the label to divide field by length. 2) Read the “Decimal Value” label on page 123 for the desired field length. 3) Read the “Validate” label on the same page to complete this setting. Divide Field 4 by Length … FIELD 5 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 124 for the desired character string. 119 Update 1600 Series Barcode Scanner User Guide 3) Read the “Validate” label on the same page to complete this setting. Select Field Separator to Divide Field 5 … Discard Separator *Include Separator 1) Read the label to divide field by length. 2) Read the “Decimal Value” label on page 123 for the desired field length. 3) Read the “Validate” label on the same page to complete this setting. Divide Field 5 by Length … ADDITIONAL FIELDS Up to five additional fields can be created for each editing format; each of them is numbered from AF1 to AF5 accordingly. 1) Read the label to specify an additional field, one at a time. 2) Read the “Hexadecimal Value” label on page 124 for the desired additional field. 3) Read the “Validate” label on the same page to complete this setting. Additional Field 1 … Additional Field 2 … 120 End Programming Format Chapter 6 ! Ζ Additional Field 3 … Additional Field 4 … Additional Field 5 … If "Keyboard Wedge" is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type. Key Status Key Type Scan Code Up to 2 scan code values are allowed – each requires two hexadecimal values. N/A Normal Key Up to 4 character strings are allowed – each requires two hexadecimal values. Default setting Add Shift Add Left Ctrl Add Left Alt Add Right Ctrl Add Right Alt Add Break For example, read labels for [Add Shift], [A], [Add Shift], and [B]. 6.2.6 FIELD TRANSMISSION SEQUENCE After configuring the data fields and additional fields, you must now program the transmission sequence of these fields that comprise the final data. This field transmission sequence can be assigned in any desired order and fields can be assigned multiple times as well. Note: Up to twelve fields can be assigned. 1) Read the “Start” label to begin with programming the field transmission sequence. Start (Programming) … 121 Update 1600 Series Barcode Scanner User Guide 2) Program the transmission sequence by reading the desired fields as well as additional fields. Field 1 Field 2 Field 3 Field 4 Field 5 Field 6 Additional Field 1 Additional Field 2 Additional Field 3 Additional Field 4 Additional Field 5 3) Read the “End” label on the same page to complete this setting. End 122 End Programming Format Chapter 6 ! Ζ 6.3 PROGRAMMING EXAMPLES 6.3.1 EXAMPLE I Extract data from the 10th character to the 19th character... The editing format should be configured as follows: Total Number of Fields – 3. Field 1 Setting – Divide Field by Field Length, and set length to 9. Field 1 data starts from the 1st character to the 9th character. Field 2 Setting – Divide Field by Field Length, and set length to 10. Field 2 data starts from the 10th character to the 19th character. Field Transmission Sequence – F2. 6.3.2 EXAMPLE II Extract the date code, item number, and quantity information from barcodes. Data in a barcode is encoded like this: From the 1st character to the 6th character is the date code. From the 7th character to the "-" character is the item number. After the "-" character is the quantity information. Data will be transmitted like this: The item number goes first, then a TAB character, followed by the date code, then another TAB character, and finally the quantity information. The editing format should be configured as follows: Total Number of Fields – 3. Field 1 Setting – Divide Field by Field Length, and set length to 6. Field 1 data starts from the 1st character to the 6th character. Field 2 Setting – Divide Field by Field Terminating String, and set the character string to [-]. Field 2 data starts from the 7th character until the [-] character is met. Additional Field 1 created and set to one [TAB] character. Field Transmission Sequence – F2 A1 F1 A1 F3. 123 Update 1600 Series Barcode Scanner User Guide 124 End Programming Format SPECIFICATIONS Optical Characteristics 1660 Scan Engine Non-contact type Optical Sensor CCD, 2500 pixels Light Source Red LED Wavelength 625 nm RF Characteristics Bluetooth Module Bluetooth Specification Version 2.0, Class 3 Coverage (line-of-sight) Up to 3 meters Profiles Supported Serial Port Profile (SPP), Human Interface Device Profile (HID) Connected Devices 1 for Bluetooth HID and up to 7 scanners for Bluetooth SPP Physical Characteristics Color Dark grey Switch Push-button switch, plus [Delete] key Dimensions 95 mm (L) 35 mm (W) 20 mm (H) Weight Approx. 50 g Electrical Characteristics Battery 2 AAA Alkaline batteries 125 Update 1600 Series Barcode Scanner User Guide Environmental Characteristics Temperature Humidity (Non-condensing) Operating 0 °C to 50 °C Storage -20 °C to 60 °C Operating 10% to 90% Storage 5% to 95% Electrostatic Discharge ± 15 kV air discharge, ± 8 kV direct discharge EMC Regulation FCC, CE, C-Tick, MIC, BSMI TELEC, NCC, RSS-210 Programming Support Configuration via Setup Labels Use setup labels or host serial commands. Software Windows-based ScanMaster Firmware upgradeable Download firmware updates via the download utility. 126 Enter Setup Appendix I NUMERAL SYSTEMS DECIMAL SYSTEM Decimal Validate the Values Validate Update Abort 127 1600 Series Barcode Scanner User Guide HEXADECIMAL SYSTEM HexaDecimal 128 Enter Setup Appendix I ! Ζ Validate the Values Validate ENTERING PIN CODE FOR BLUETOOTH CONNECTION By default, the Bluetooth PIN code is set to “0000”. Maximum 16 characters are allowed. Note: When using Bluetooth HID, some driver of Bluetooth dongle may not support pre-defined PIN code for authentication. In this case, make sure you disable authentication before pairing. The host PIN code will be displayed on the computer screen. Have the scanner read the setup barcode “Enter PIN Code in Decimal” to input the matching PIN code quickly. Enter PIN Code in Hexadecimal … Enter PIN Code in Decimal … 1) Read one of the labels above to specify the PIN code, in decimal or hexadecimal. 2) Read the “Decimal Value” label on page 123 or the “Hexadecimal Value” label on page 124 for the desired digits or character string. 3) Read the “Validate” label on the same page to complete this setting. Update Abort 129 1600 Series Barcode Scanner User Guide 130 Enter Setup Appendix II KEYBOARD WEDGE TABLE & ASCII TABLE KEYBOARD WEDGE TABLE F2 SP INS F3 DLT F4 Home F5 End F6 Up F7 Down F8 Left F9 BS F10 HT F11 LF F12 Right ESC PgUp Exec CR CR* PgDn F1 Dly ENTER* Note: (1) b~k: Digits of numeric keypad. (2) CR*/Send/ENTER*: ENTER key on the numeric keypad. KEY TYPE If "Keyboard Wedge" is configured for interface, Key Type and Key Status will then become applicable. 131 Update 1600 Series Barcode Scanner User Guide *Normal Scan Code KEY STATUS Decide whether or not to change key status when “Normal Key” is selected for Key Type. Add Shift Add Left Ctrl Add Left Alt Add Right Ctrl Add Right Alt 132 Enter Setup Appendix II ! Ζ USER-DEFINED SCAN CODE 1) Read the “Set Scan Code” label to define new scan code. Set Scan Code 2) Read the “Hexadecimal Value” label on page 124 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. 4) Read the “Confirm” label to confirm the action. Confirm ASCII TABLE DLE SP SOH DC1 STX DC2 ETX DC3 EOT DC4 ENQ NAK ACK SYN BEL ETB BS CAN HT EM LF SUB VT ESC FF FS CR GS SO RS SI US DEL 133 Update 1600 Series Barcode Scanner User Guide 134 Enter Setup Appendix III HOST SERIAL COMMANDS SERIAL COMMANDS #@NNNNNNPurpose To configure the scanner. Remarks nnnnnn – the six digits of command parameters. For example, “109952” is to list the current Code ID settings. List Page 3 Serial Command “0x23” + “0x40” + “0x31” + “0x30” + “0x39” + “0x39” + “0x35” + “0x32” + “0x0d” #@ - - - - Purpose To halt the scanner. Remarks “0x23” + “0x40” + “0x2d” + “0x2d” + “0x2d” + “0x2d” + “0x0d” #@ . . . . Purpose To resume operation. Remarks “0x23” + “0x40” + “0x2e” + “0x2e” + “0x2e” + “0x2e” + “0x0d” #@//// Purpose To respond with a beep. Remarks “0x23” + “0x40” + “0x2f” + “0x2f” + “0x2f” + “0x2f” + “0x0d” #@TRIGOFF Purpose Disable software trigger Remarks “0x23” + “0x40” + “0x54” + “0x52” + “0x49” + “0x47” + “0x4f” ” + “0x46” ” + “0x46” + “0x0d” #@TRIGON Purpose Enable software trigger Remarks “0x23” + “0x40” + “0x54” + “0x52” + “0x49” + “0x47” + “0x4f” ” + “0x4e” ” + “0x0d” 135 Update 1600 Series Barcode Scanner User Guide EXAMPLE Send the serial commands via RS-232 interface or Bluetooth SPP. For example, run HyperTerminal on the host computer. For the scanner to change the beeper to medium volume and beep – #@101011 #@//// For the scanner to change the beeper to minimal volume and beep – #@101010 #@//// For the scanner to change the beeper frequency to 8 kHz (for Good Read Beep only) and beep – #@101001 #@//// For the scanner to change the beeper length to longest (for Good Read Beep only) and beep – #@101008 #@//// 136 Enter Setup Appendix IV UPGRADING FIRMWARE You can only upgrade firmware of one Bluetooth scanner at a time. For example, you must turn off each of the rest 1660 scanner when there is more than one scanner connected to your computer via a Bluetooth dongle. Note: In case it fails downloading due to low battery, make sure the targe scanner is loaded with a fully charged battery. 1) Connect the Bluetooth dongle to your computer via the USB port. 2) Refer to 3.2 Connecting via Bluetooth Dongle for the target scanner to establish a connection with your computer via the dongle. Read the following labels in sequence to configure the scanner to use Bluetooth Serial Port as output interface. Enter Setup Activate Bluetooth SPP (and read labels for PIN code …) Update 3) Read the following labels in sequence for the scanner to enter the download mode. The scanner will respond with beeps to indicate it is ready for downloading. 137 Update 1600 Series Barcode Scanner User Guide Enter Setup Download 4) Run the download utility “ProLoad.exe” or “Download.exe” on your computer. (Download.exe requires version 2.3 or later!) Open the firmware update “*.shx”, and select the correct COM port. Baud rate – 115,200 bps Data bit –8 Parity – None Flow control – None 5) The scanner will automatically restart itself when upgrading firmware is completed successfully. 138 Enter Setup
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 6.0 (Windows) Create Date : 2008:04:03 20:04:57+08:00 Modify Date : 2008:04:07 17:54:48+08:00 Metadata Date : 2008:04:07 17:54:48+08:00 Document ID : uuid:e048809f-7861-464b-ad8a-a4472e296fca Instance ID : uuid:9b34729c-2822-4964-b74a-1ed48310bc72 Format : application/pdf Title : untitled Page Count : 150EXIF Metadata provided by EXIF.tools