CipherLab 3656CRADLE Cradle User Manual
CipherLab Co., Ltd. Cradle Users Manual
Users Manual
1560/1562 Barcode Scanner 3656 CRADLE Setup barcodes included. Version 1.21 Copyright © 2009~2017 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided under a license agreement containing restrictions on use and disclosure and is also protected by copyright law. Reverse engineering of the software is prohibited. Due to continued product development this information may change without notice. The information and intellectual property contained herein is confidential between CIPHERLAB and the client and remains the exclusive property of CIPHERLAB CO., LTD. If you find any problems in the documentation, please report them to us in writing. CIPHERLAB does not warrant that this document is error-free. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior written permission of CIPHERLAB CO., LTD. For product consultancy and technical support, please contact your local sales representative. Also, you may visit our web site for more information. The CipherLab logo is a registered trademark of CIPHERLAB CO., LTD. All brand, product and service, and trademark names are the property of their registered owners. The editorial use of these names is for identification as well as to the benefit of the owners, with no intention of infringement. CIPHERLAB CO., LTD. Website: http://www.cipherlab.com IMPORTANT NOTICES FOR USA This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. FOR CANADA This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled "Digital Apparatus," ICES-003 of Industry Canada. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux appareils numeriques de Classe B prescrites dans la norme sur le material brouilleur: "Appareils Numeriques," NMB-003 edictee par l'Industrie. FOR EUROPE This device complies with the essential requirements of the R&TTE Directive 1999/5/EC. The following test methods have been applied in order to prove presumption of conformity with the essential requirements of the R&TTE Directive 1999/5/EC: - EN 60950-1: 2006+A11:2009+A1:2010+A12:2011+A2:2013 Safety of Information Technology Equipment - EN 301 489-1 V2.1.1: 2016 Electromagnetic compatibility and Radio Spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements - EN 301 489-3 V2.1.0: 2016 Electromagnetic compatibility and Radio Spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 40 GHz - EN 301 489-17 V3.1.1: 2016 ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for Broadband Data Transmission Systems; Harmonised Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU - EN 300 328 V2.1.1: 2016 Wideband transmission systems;Data transmission equipment operating in the 2,4 GHz ISM band and using wide band modulation techniques; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU FOR HANDHAND-HELD PRODUCT WITH RF FUNCTIONS The 1560/1562 unit (FCC ID: Q3N-1560) complies with FCC radiation exposure limits set forth for uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement C to OET65. The unit has very low level of RF energy that it is deemed to comply without testing of specific absorption ratio (SAR). The 3656 CRADLE CRADLE unit (FCC ID: Q3N-3656CRADLE) complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. It only operated in hand-held used. If you only transfer data to the host wirelessly, please keep the minimum distance 20 cm between machine & your body. FOR PRODUCT WITH LASER LASER CAUTION This laser component emits FDA / IEC Class 2 laser light at the exit port. Do not stare into beam. SAFETY PRECAUTIONS DO NOT expose the scanner to any flammable sources. Under no circumstances, internal components are self-serviceable. For AC power adaptor, a socket outlet shall be installed near the equipment and shall be easily accessible. Make sure there is stable power supply for the scanner or its peripherals to operate properly. CARE & MAINTENANCE Use a clean cloth to wipe dust off the scanning window and the body of the scanner. DO NOT use/mix any bleach or cleaner. If finding the scanner malfunctioning, write down the specific scenario and consult the local sales representative. RELEASE NOTES Version Date Notes 1.21 Jul. 13, 2017 Modified: 2.3.1 Activate BT SPP Master Mode – settings as a single 1D barcode (SeTcOn) for connecting to a target device added Modified: 3.1.1 Connect to 3656 CRADLE – settings as a single 1D barcode (SeTcOn) for connecting to a target device added New: 4.2.5/4.3.5/4.4.5 – Code 25 Security Level (1560P Only) Modified: 4.21.2 – setting barcodes of Transmit and Do Not Transmit exchanged 1.20 Mar. 15, 2017 Modified: Symbology Supported – Code 11, Trioptic Code 39 added Modified: 2.1.6 – set “By Character” to default Modified: 2.1.7 – set “Use Trigger Key to Show or Hide Keypad” to default Modified: 2.1.8 – set “Fast” transmit speed to default New: 2.1.10 BT HID Auto-Reconnection (1560P Only) Modified: 2.6.5 – set “By Character” to default Modified: 3.2.4 – set “Enable” (simple pairing) to default Modified: 4.5.5 – set “Normal” (Code 39 security level) to default New: 4.6 Trioptic Code 39 Modified: 4.8.1 – set “Normal” (Code 128 security level) to default Modified: 4.10.4 – set “Normal” (EAN-13 security level) to default New: 4.17.8 Security Level (GS1 DataBar) New: 4.21 Code 11 Modified: 5.2.2 Symbologies for Character Substitution (All 3 Sets) – Code 11, Trioptic Code 39 added Modified: 5.4.1 Select Pre-defined Code ID – AIM Code ID added Modified: 5.4.2 Change Code ID – Code 11, Trioptic Code 39 added Modified: 5.5 Length Code – Code 11, Trioptic Code 39 added Modified: 6.3.1 Applicable Code Type – Code 11, Trioptic Code 39 added 1.17 Dec. 17, 2015 Modified: 1.11.2 - setting barcodes for Auto-sense Detection, Auto-sense Detection Level, and Auto Power On added Modified: 2.1.7 – setting barcodes for showing/hiding iPhone/iPad onscreen keypad added (1560P) 1.16 Nov. 10, 2015 New: 1.11.1 Behavior of 1560 New: 1.11.2 Behavior of 1560P New: 1.11.3 Ambient Light New: 4.5.6 Asterisks as Data Characters 1.15 Aug. 21, 2015 New: 2.3.6 BT SPP Master Auto-Reconnection (1560P Only) 1.14 Aug. 17, 2015 New: 2.1.9 BT HID Slave/Master Switching New: 2.2.4 BT SPP Slave Hardware Flow Control New: 2.3.5 BT SPP Master Hardware Flow Control Modified: descriptions relating to CD-ROM removed 1.13 Mar. 14, 2014 “ Modified: Care & Maintenance – Keep the scanner away from any magnets and magnetic fields to prevent the laser engine from malfunctioning.” added New: 4.8.3 – GTIN-13 format barcodes added New: 4.10.3 – GS1 formatting barcodes added New: 4.10.4 – Application ID Mark barcodes added New: 4.16.5 – Field Separator barcode added New: 4.16.6 – GS1 Formatting barcodes added New: 4.16.7 – Application ID Mark barcodes added 1.12 Oct. 09, 2013 New: 2.1.8 Transmit Speed – setting barcodes (for BT HID) added New: 3.2.4 Secure Simple Pairing (SSP) setting barcodes added New: 4.11.1 ISBT Concatenation – setting barcodes added 1.11 Jan. 02, 2013 Modified: Symbologies Supported (EAN-128): default value to Enabled – Code 128 GS1-128 New: 1.2.3 Free Memory barcode Modified: 2.1/2.4/2.6 Add Keyboard Type: PCAT (Hungarian), PCAT (Swiss German), PCAT (Danish) Modified: 2.7/3.1 Note for Driver version 5.4 or later required New: 4.1.4 Security Level (Codabar) setup barcodes New: 4.5.5 Security Level (Code 39) setup barcodes New: 4.7.1 Security Level (Code 128) setup barcodes Modified: 4.10 GS1-128 (EAN-128) - GS1-128 default to Enable Modified: Appendix II - #@RDSN command added 1.10 Aug 31, 2011 New: “Auto Power Off Ignoring Scan Mode” is added. Sections involved are: 1.09 May 25, 2011 Renamed section 1.1.1 “Turn on/off the Scanner” Modified section: 1.1.2 “Power Economy”. Adjusted new Connection” section: 1.1.3 “Power Economy vs. WPAN Modified: 3656 CRADLE +USB+Adaptor issue Modified: 2.1 BT HID — add Inter-Character Delay Modified: 2.6 USB HID via 3656 CRADLE — add Inter-Character Delay 1.08 Mar. 11, 2011 New: Quick Start — Create One-Scan Setup Barcodes (e.g. ”109950” ”#@109950#”) Modified: 1.11 Auto-Sense Mode (1560 Only) — add High Sensitivity behavior Modified: Specifications — Power Adaptor 1.07 Jan. 10, 2011 Modified: Introduction, Product Highlights — add CipherConnect Modified: 4.10 GS1-128 (EAN-128) — Cannot read when disabled since firmware v1.01 Modified: 5.6.1 Edit a Concatenation of Barcodes — Code type for ISBT 128 New: 6.4.5 Pause Field Setting Modified: 6.5 Configuring Format — Define Transmission Sequence (add Pause Field, Null Character Field ) 1.06 Nov. 30, 2010 Modified: Introduction, Symbologies Supported — add support of more RSS symbologies New: Introduction — Charging the Battery via Charger Modified: 1.1.2 Auto Power Off & Power-Saving Modified: 1.4 Beeper — describe “Low Battery Alarm” New: 2.1.6 Keypad Support for iPhone/iPad Modified: 3.2.3 Connect to Dongle — describe random PIN in Step 12 Modified: 4.16 GS1 DataBar (RSS Family) Modified: 4.16.2 GS1 DataBar Omnidirectional (RSS-14) Modified: 4.16.3 GS1 DataBar Expanded (RSS Expanded) Modified: 5.2 Character Code/Normal Key 1.05 Apr. 09, 2010 Substitution — add table for Scan Modified: 1.1.2 Auto Power Off & Power-Saving Modified: 2.1.1 Activate BT HID & Select Keyboard Type — add Turkish Modified: 2.1.3 Keyboard Settings — BT HID supports “Alphabets Layout” Modified: 2.1.5 HID Character Transmit Mode Modified: 2.2 BT SPP Slave Modified: 2.3 BT SPP Master Modified: 2.4.1 Activate Keyboard Wedge & Select Keyboard Type — add Turkish Modified: 2.5.2 Baud Rate — add setup barcode for 4800 bps (100100) Modified: 2.5.2 Baud Rate — change default baud rate to 115200 bps Modified: 2.6.1 Activate USB HID & Select Keyboard Type — add Turkish Modified: 2.6.2 Keyboard Settings — USB HID supports “Alphabets Layout” Modified: 2.6.4 HID Character Transmit Mode New: 3.1.3 Configure Related Settings — Sniff Mode Modified: 4.9.4 Security Level Modified: Appendix III Keyboard Wedge Table — remove settings for user-defined scan code Modified: Appendix III Keyboard Wedge Table — provide examples 1.04 Mar. 02, 2010 Modified: Charging the Battery via 3656 CRADLE — suggest connecting power cord for USB 1.03 Oct. 30, 2009 Modified: 1.10 Auto-Sense Mode (1560 Only) — Continuous mode as an alternative Modified: 1.13 Symbologies Supported — ISBT 128 enabled by default Modified: 5.2.2 Symbologies for Character Substitution (All 3 Sets) — add ISBT 128 Modified: 5.4.1 Select Pre-defined Code ID — add ISBT 128 Modified: 5.4.2 Change Code ID — add ISBT 128 Modified: 5.5 Length Code — add ISBT 128 Modified: 6.3.1 Applicable Code Type (for Editing Format) — add ISBT 128 1.02 July 07, 2009 Modified: Charging the Battery via 3656 CRADLE —charging time changed from 3 to 5 (hr) Modified: 1.1 Battery — charging time changed from 3 to 5 (hr) Modified: 1.1.2 Auto Power Off & Power-Saving — add setup barcode for Power-Saving setting (101021) Modified: 3.2.2 Configure Related Settings — Authentication 1.01 June 3, 2009 Modified: 1.10 Auto-Sense Mode — Power supply cord is required. Modified: Appendix II Host Serial Commands 1.00 Apr. 29, 2009 Initial release CONTENTS IMPORTANT NOTICES ................................................................ ................................................................................................ ........................................................................ ........................................- 3 For USA........................................................................................................................................ - 3 For Canada ................................................................................................................................. - 3 For Hand-held Product with RF Functions ...................................................................... - 4 For Product with Laser ........................................................................................................... - 4 Safety Precautions .................................................................................................................. - 5 Care & Maintenance................................................................................................................ - 5 RELEASE NOTES ................................................................ ................................................................................................ .................................................................................... ....................................................- 5 INTRODUCTION................................ ................................................................ ................................................................................................ ........................................................................................ ........................................................ 1 Getting Familiarized with 1560/1562 and 3656 CRADLE ................................................ 2 Installing the Battery to 1560/1562 ............................................................................... 2 Setting up 3656 CRADLE ........................................................................................................ 3 Charging the Battery via 3656 CRADLE ............................................................................ 5 Charging the Battery via Charger .................................................................................... 6 Inside the Package ...................................................................................................................... 8 Product Highlights ....................................................................................................................... 8 Symbologies Supported ............................................................................................................ 9 QUICK START................................................................ ................................................................................................ ........................................................................................... ........................................................... 13 Enter Configuration Mode....................................................................................................... 15 Exit Configuration Mode .......................................................................................................... 15 Default Settings ......................................................................................................................... 16 Save User Settings as Defaults....................................................................................... 16 Restore User Defaults ......................................................................................................... 16 Restore System Defaults ................................................................................................... 16 Read a Setup Barcode ............................................................................................................. 17 Configure Parameters ......................................................................................................... 17 List the Current Settings ................................................................................................... 21 Create One-Scan Setup Barcodes ....................................................................................... 23 UNDERSTANDING THE BARCODE SCANNER ............................................................ ............................................................ 25 1.1 Battery ................................................................................................................................... 25 1.1.1 Turn on/off the Scanner ........................................................................................ 25 1.1.2 Power Economy ......................................................................................................... 26 1.1.3 Power Economy vs. WPAN Connection ............................................................ 29 1.2 Memory .................................................................................................................................. 31 1.2.1 Transmit Buffer ......................................................................................................... 31 1.2.2 Memory Mode............................................................................................................. 32 1.2.3 Free Memory .............................................................................................................. 33 1560/1562 Series Barcode Scanner User Guide 1.3 LED Indicator....................................................................................................................... 34 1.3.1 Good Read LED.......................................................................................................... 35 1.3.2 Good Read LED Duration ....................................................................................... 35 1.4 Beeper .................................................................................................................................... 36 1.4.1 Beeper Volume .......................................................................................................... 37 1.4.2 Good Read Beep ....................................................................................................... 38 1.4.3 Low Battery Alarm ................................................................................................... 39 1.5 Send “NR” to Host ............................................................................................................. 39 1.6 Scan Modes .......................................................................................................................... 40 1.6.1 Continuous Mode ...................................................................................................... 41 1.6.2 Test Mode .................................................................................................................... 41 1.6.3 Laser Mode .................................................................................................................. 42 1.6.4 Auto Off Mode ............................................................................................................ 42 1.6.5 Auto Power Off Mode .............................................................................................. 42 1.6.6 Alternate Mode .......................................................................................................... 43 1.6.7 Aiming Mode ............................................................................................................... 43 1.6.8 Multi-Barcode Mode ................................................................................................. 44 1.7 Scanning Timeout .............................................................................................................. 45 1.8 Delay between Re-read ................................................................................................... 46 1.9 Read Redundancy for All Symblogies ........................................................................ 47 1.10 Addon Security for UPC/EAN Barcodes................................................................... 48 1.11 Auto-Sense Mode (1560/1560P Only) .................................................................... 49 1.11.1 Behavior of 1560 .................................................................................................... 49 1.11.2 Behavior of 1560P ................................................................................................. 50 1.11.3 Ambient Light .......................................................................................................... 51 1.12 CCD Sensor Always Active (1560 Only) ................................................................. 52 1.13 Negative Barcodes .......................................................................................................... 52 1.14 Effective Decoding Area................................................................................................ 53 1.14.1 Positioning Window ............................................................................................... 53 1.14.2 Adjusting Window .................................................................................................. 54 SELECTING OUTPUT INTERFACE ................................................................ ................................................................................... ................................................... 55 2.1 BT HID ................................................................................................................................... 56 2.1.1 Activate BT HID & Select Keyboard Type ....................................................... 57 2.1.2 Reset Connection ...................................................................................................... 58 2.1.3 Keyboard Settings .................................................................................................... 59 2.1.4 Inter-Character Delay ............................................................................................. 66 2.1.5 Inter-Function Delay ............................................................................................... 66 2.1.6 HID Character Transmit Mode ............................................................................. 67 2.1.7 Keypad Support for iPhone/iPad......................................................................... 68 2.1.8 Transmit Speed ......................................................................................................... 68 2.1.9 BT HID Slave/Master Switching .......................................................................... 68 2.1.10 BT HID Auto-Reconnection (1560P Only)..................................................... 69 2.2 BT SPP Slave ....................................................................................................................... 70 2.2.1 Activate BT SPP Slave Mode................................................................................. 70 2.2.2 Inter-Function Delay ............................................................................................... 70 1560/1562 Series Barcode Scanner User Guide 2.2.3 ACK/NAK Timeout .................................................................................................... 71 2.2.4 BT SPP Slave Hardware Flow Control ............................................................... 71 2.3 BT SPP Master ..................................................................................................................... 72 2.3.1 Activate BT SPP Master Mode .............................................................................. 72 2.3.2 Inter-Function Delay ............................................................................................... 74 2.3.3 ACK/NAK Timeout .................................................................................................... 74 2.3.4 Switch between Master/Slave Mode ................................................................. 76 2.3.5 BT SPP Master Hardware Flow Control............................................................. 76 2.3.6 BT SPP Master Auto-Reconnection (1560P Only) ........................................ 76 2.4 Keyboard Wedge via 3656 CRADLE ............................................................................... 77 2.4.1 Activate Keyboard Wedge & Select Keyboard Type .................................... 78 2.4.2 Keyboard Settings .................................................................................................... 79 2.4.3 Inter-Character Delay ............................................................................................. 87 2.4.4 Inter-Function Delay ............................................................................................... 87 2.5 RS-232 via 3656 CRADLE .................................................................................................. 88 2.5.1 Activate RS-232 Interface..................................................................................... 88 2.5.2 Baud Rate .................................................................................................................... 88 2.5.3 Data Bits ...................................................................................................................... 89 2.5.4 Parity ............................................................................................................................. 89 2.5.5 Stop Bit ......................................................................................................................... 90 2.5.6 Flow Control ................................................................................................................ 90 2.5.7 Inter-Character Delay ............................................................................................. 91 2.5.8 Inter-Function Delay ............................................................................................... 91 2.5.9 ACK/NAK Timeout .................................................................................................... 92 2.6 USB HID via 3656 CRADLE................................................................................................ 93 2.6.1 Activate USB HID & Select Keyboard Type .................................................... 94 2.6.2 Keyboard Settings .................................................................................................... 95 2.6.3 Inter-Character Delay ...........................................................................................101 2.6.4 Inter-Function Delay .............................................................................................102 2.6.5 HID Character Transmit Mode ...........................................................................102 2.7 USB Virtual COM via 3656 CRADLE..............................................................................103 2.7.1 Activate USB Virtual COM....................................................................................103 2.7.2 Inter-Function Delay .............................................................................................103 2.7.3 ACK/NAK Timeout ..................................................................................................104 SETTING UP A WPAN CONNECTION................................ ................................................................ ........................................................................... ........................................... 105 3.1 Connecting via 3656 CRADLE .........................................................................................107 3.1.1 Connect to 3656 CRADLE........................................................................................107 3.1.2 Change Interface ....................................................................................................108 3.1.3 Configure Related Settings .................................................................................110 3.2 Connecting via Bluetooth® Dongle............................................................................111 3.2.1 Change Interface ....................................................................................................111 3.2.2 Configure Related Settings .................................................................................112 3.2.3 Connect to Dongle ..................................................................................................115 3.2.4 Secure Simple Pairing (SSP) ..............................................................................122 CHANGING SYMBOLOGY SETTINGS ................................................................ ........................................................................... ........................................... 123 4.1 Codabar ...............................................................................................................................124 1560/1562 Series Barcode Scanner User Guide 4.1.1 Start/Stop Characters Selection .......................................................................124 4.1.2 Start/Stop Transmission ......................................................................................125 4.1.3 CLSI Conversion......................................................................................................125 4.1.4 Security Level ..........................................................................................................125 4.2 Code 25 – Industrial 25 ................................................................................................126 4.2.1 Start/Stop Pattern Selection ..............................................................................126 4.2.2 Verify Check Digit ...................................................................................................126 4.2.3 Transmit Check Digit .............................................................................................127 4.2.4 Code Length Qualification ...................................................................................127 4.2.5 Security Level (1560P Only) ..............................................................................128 4.3 Code 25 – Interleaved 25 ............................................................................................129 4.3.1 Start/Stop Pattern Selection ..............................................................................129 4.3.2 Verify Check Digit ...................................................................................................130 4.3.3 Transmit Check Digit .............................................................................................130 4.3.4 Code Length Qualification ...................................................................................131 4.3.5 Sesurity Level (1560P Only) ..............................................................................131 4.4 Code 25 – Matrix 25 .......................................................................................................132 4.4.1 Start/Stop Pattern Selection ..............................................................................132 4.4.2 Verify Check Digit ...................................................................................................133 4.4.3 Transmit Check Digit .............................................................................................133 4.4.4 Code Length Qualification ...................................................................................134 4.4.5 Security Level (1560P Only) ..............................................................................134 4.5 Code 39 ...............................................................................................................................135 4.5.1 Start/Stop Transmission ......................................................................................135 4.5.2 Verify Check Digit ...................................................................................................135 4.5.3 Transmit Check Digit .............................................................................................136 4.5.4 Standard/Full ASCII Code 39.............................................................................136 4.5.5 Security Level ..........................................................................................................136 4.5.6 Asterisks (*) as Data Characters .....................................................................137 4.6 Trioptic Code 39 ...............................................................................................................137 4.7 Code 93 ...............................................................................................................................137 4.8 Code 128 .............................................................................................................................137 4.8.1 Security Level ..........................................................................................................138 4.9 EAN-8 ...................................................................................................................................138 4.9.1 Convert to EAN-13 .................................................................................................139 4.9.2 Transmit Check Digit .............................................................................................139 4.9.3 Conversion Format .................................................................................................139 4.10 EAN-13 ..............................................................................................................................141 4.10.1 ISBN Conversion ..................................................................................................142 4.10.2 ISSN Conversion ..................................................................................................142 4.10.3 Transmit Check Digit ..........................................................................................142 4.10.4 Security Level ........................................................................................................143 4.11 GS1-128 (EAN-128) .....................................................................................................144 4.11.1 Code ID Transmission ........................................................................................144 4.11.2 Field Separator (GS Character) ......................................................................144 4.11.3 GS1 Formatting ....................................................................................................145 1560/1562 Series Barcode Scanner User Guide 4.11.4 Application ID Mark .............................................................................................145 4.12 ISBT 128...........................................................................................................................146 4.12.1 ISBT Concatenation ............................................................................................146 4.13 MSI .....................................................................................................................................147 4.13.1 Verify Check Digit ................................................................................................147 4.13.2 Transmit Check Digit ..........................................................................................147 4.13.3 Code Length Qualification .................................................................................148 4.14 French Pharmacode ......................................................................................................149 4.14.1 Transmit Check Digit ..........................................................................................149 4.15 Italian Pharmacode ......................................................................................................150 4.15.1 Transmit Check Digit ..........................................................................................150 4.16 Plessey ..............................................................................................................................151 4.16.1 Convert to UK Plessey ........................................................................................151 4.16.2 Transmit Check Digit ..........................................................................................151 4.17 GS1 DataBar (RSS Family) .......................................................................................152 4.17.1 Code ID Selection ................................................................................................152 4.17.2 GS1 DataBar Omnidirectional (RSS-14) .....................................................153 4.17.3 GS1 DataBar Expanded (RSS Expanded) ...................................................155 4.17.4 GS1 DataBar Limited (RSS Limited).............................................................156 4.17.5 Field Separator (GS Character) ......................................................................157 4.17.6 GS1 Formatting ....................................................................................................157 4.17.7 Application ID Mark .............................................................................................157 4.17.8 Security Level ........................................................................................................158 4.18 Telepen..............................................................................................................................159 4.18.1 Telepen Output – Full ASCII/Numeric .........................................................159 4.19 UPC-A.................................................................................................................................160 4.19.1 Convert to EAN-13 ..............................................................................................161 4.19.2 System Number Transmission ........................................................................161 4.19.3 Transmit Check Digit ..........................................................................................161 4.20 UPC-E .................................................................................................................................162 4.20.1 System Number Selection ................................................................................163 4.20.2 Convert to UPC-A .................................................................................................163 4.20.3 System Number Transmission ........................................................................164 4.20.4 Transmit Check Digit ..........................................................................................164 4.21 Code 11 .............................................................................................................................165 4.21.1 Verify Check Digit ................................................................................................165 4.21.2 Transmit Check Digit ..........................................................................................166 4.21.3 Security Level ........................................................................................................166 DEFINING OUTPUT FORMAT ................................................................ .......................................................................................... .......................................................... 167 5.1 Letter Case .........................................................................................................................167 5.2 Character Substitution ...................................................................................................168 5.2.1 Select a Set for Character Substitution .........................................................169 5.2.2 Symbologies for Character Substitution (All 3 Sets) ................................170 5.3 Prefix/Suffix Code ............................................................................................................176 5.4 Code ID................................................................................................................................177 1560/1562 Series Barcode Scanner User Guide 5.4.1 Select Pre-defined Code ID ................................................................................177 5.4.2 Change Code ID ......................................................................................................180 5.4.3 Clear Code ID Settings .........................................................................................181 5.5 Length Code .......................................................................................................................182 5.6 Multi-Barcode Editor .......................................................................................................186 5.6.1 Edit a Concatenation of Barcodes ....................................................................187 5.6.2 Activate the Concatenation of Barcodes........................................................189 5.7 Removal of Special Character .....................................................................................190 APPLYING FORMATS FOR DATA EDITING .............................................................. .............................................................. 191 6.1 Activating Editing Formats ...........................................................................................192 6.1.1 Activate Editing Formats......................................................................................192 6.1.2 Exclusive Data Editing ..........................................................................................193 6.2 How to Configure Editing Formats ............................................................................194 6.2.1 Select Format to Configure .................................................................................195 6.2.2 Restore Default Format ........................................................................................196 6.3 Configuring Format — Define Data Criteria ..........................................................197 6.3.1 Applicable Code Type ............................................................................................197 6.3.2 Data Length ..............................................................................................................204 6.3.3 Matching String & Location .................................................................................205 6.4 Configuring Format — Define Data Field ................................................................205 6.4.1 Start Position ............................................................................................................205 6.4.2 Field Adjustment .....................................................................................................206 6.4.3 Total Number of Fields .........................................................................................206 6.4.4 Field Settings............................................................................................................207 6.4.5 Pause Field Setting ................................................................................................213 6.5 Configuring Format — Define Transmission Sequence .....................................214 6.6 Programming Examples ................................................................................................216 6.6.1 Example I ..................................................................................................................216 6.6.2 Example II .................................................................................................................217 SPECIFICATIONS ................................................................ ................................................................................................ ................................................................................. ................................................. 219 FIRMWARE UPGRADE ................................................................ ................................................................................................ ........................................................................ ........................................ 221 How to Upgrade 1560/1562 Firmware ............................................................................221 Using 3656 CRADLE ..............................................................................................................221 Using Bluetooth® Dongle .................................................................................................224 How to Upgrade 3656 CRADLE Firmware ..........................................................................226 Upgrading 3656 CRADLE CPU Firmware .......................................................................226 Upgrading 3656 CRADLE USB Bridge Firmware ........................................................228 HOST SERIAL COMMANDS ................................................................ .............................................................................................. .............................................................. 231 1560/1562 Serial Commands .............................................................................................231 Example .................................................................................................................................232 3656 CRADLE Setup Barcodes & Serial Commands ......................................................233 3656 CRADLE Setup Barcodes ..........................................................................................234 Example .................................................................................................................................236 1560/1562 Series Barcode Scanner User Guide KEYBOARD WEDGE TABLE ................................................................ .............................................................................................. .............................................................. 237 Key Type & Status...................................................................................................................238 Key Type ................................................................................................................................238 Key Status .............................................................................................................................238 Example.......................................................................................................................................239 NUMERAL SYSTEMS ................................................................ ................................................................................................ ............................................................................ ............................................ 241 Decimal System .......................................................................................................................241 Hexadecimal System ..............................................................................................................242 ASCII Table ................................................................................................................................243 Entering PIN Code for Authentication ..............................................................................244 Use Preset PIN .....................................................................................................................244 Disable Authentication or Use Random PIN .............................................................245 INTRODUCTION CipherLab’s 1560 Series Barcode Scanners are specifically designed to answer your mobile demands. The versatile scanners are designed to help accelerate productivity while lowering the total cost of ownership. Intensive data collection jobs are made easier with fast, accurate barcode scanning in various working environments, especially in small businesses. Integrating short-distance wireless technology to small-form-factor scanners, the 1560/1562 scanners are ideal for carrying around, and thus give workers tether-free mobility anytime anywhere and get job done more efficiently. This line of scanners deliver data over a wireless personal network at a range of up to 90 meters and a prolonged battery life to keep business running. Owing to the slim, ergonomic design, extremely low power consumption, and powerful decoding capability, the 1560 Series Barcode Scanners are the best choice for the following applications – Receiving in Retail Product labeling & Tracking Shelf Product Replenishment Mobile Point of Sale (POS) Mobile Inventory Management Order Picking & Staging Work-In-Process Tracking Material Flow Control Transportation & Distribution Warehousing Asset Management This manual contains information on operating the scanner and using its features. We recommend that you keep one copy of the manual at hand for quick reference or maintenance purposes. To avoid any improper disposal or operation, please read the manual thoroughly before use. Thank you for choosing CipherLab products! Update 1560/1562 Series Barcode Scanner User Guide GETTING FAMILIARIZED WITH 1560/1562 1560/1562 AND 3656 CRADLE INSTALLING THE BATTERY BATTERY TO 1560/1562 1560/1562 When you first receive the package, the rechargeable battery is stored separately from the scanner. Insert the battery into the scanner first so that it can be charged when sitting in the Auto-Sense stand. Note: Any improper handling may reduce the battery life. 1) Hold the scanner still and insert the battery into the battery compartment at the bottom of the scanner. 2) Slide the battery latch to lock the battery in the compartment. 3) Hold down the trigger about 2 seconds to turn on the scanner. 4) The scanner will respond with a long beep and its LED will come on-off shortly. Note: (1) To turn off the scanner, remove the battery. Refer to settings of “Auto Power Off”. (2) For shipping and storage purposes, save the scanner and the battery separately. This will keep the battery in good condition for future use. (3) When the battery charge becomes low, you will find the scanner cannot emit scan beam and its power-on beep sounds differently. Enter Setup 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 SETTING UP 3656 CRADLE Capable of charging 1560/1562, the 3656 CRADLE stand is specifically designed for the scanner to communicate with a host computer wirelessly. The connection between the scanners and 3656 CRADLE is made easy and reliable. Refer to 3.1.1 Connect to . The 3656 CRADLE stand is also an Auto-Sense stand when used with the scanner set to Auto-Sense mode. Two LED indicators are provided for power and communications status. Power LED Meaning Red, solid --- Power ON --- --- Power OFF Communication LED Meaning --- Blue, solid Initialize Red, solid --- Failed to establish a USB connection Red, solid Blue, flashing Serial command mode with USB Virtual COM or RS-232: wait 3 seconds for starting a serial command Red, flashing Blue, flashing Serial command mode with USB HID: wait 3 seconds for pressing [Num Lock] or [Caps Lock] 5 times via keyboard --- Blue, Wait for connection request from the scanner (Slow flash at 0.5 Hz) Update 1560/1562 Series Barcode Scanner User Guide flashing --- Blue, flashing Connected with the scanner (Fast flash at 1 Hz) Red, solid Blue, flashing Failed to send data to host via USB Virtual COM (Fast flash at 1 Hz) Red, flashing --- Enter Download Mode Enter Setup 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 CHARGING THE BATTERY VIA 3656 CRADLE The battery may not be charged to full for shipment. When you first receive the package, you will need to charge the battery to full before using the scanner. When using the RS-232 cable, it takes approximately 5 hours to charge the battery to full (from the power adaptor). Note: Battery charging stops when the temperature drops below 0°C or exceeds 40°C. It is recommended to charge the battery at room temperature (18°C to 25°C) for optimal performance. 1) Install the battery to the scanner. 2) Seat the scanner in the 3656 CRADLE stand. 3) Connect the 3656 CRADLE stand to your computer or notebook via the USB or RS-232 cable. 4) Connect the power supply cord from 3656 CRADLE to a proper power outlet. Warning: RS-232/USB interface both require connecting the power supply cord. When the stand is solely on USB power, the current may be insufficient for it to function normally. You must connect the power supply cord. 5) The LED for power indication on 3656 CRADLE will become solid red. 6) The scanner LED will be flashing red during charging. When the charging is done, the LED will turn off. When charging error occurs, the LED will turn solid red. 7) The LED for communications on 3656 CRADLE will first become solid blue while initializing. Refer to the table above for details on different stage of communications. The two pivot bolts need to be tightened, or charging error may occur. Update 1560/1562 Series Barcode Scanner User Guide Warning: If the two pivot bolts are not tightened properly, charging error may occur. CHARGING THE BATTERY VIA CHARGER The battery charger is provided for charging the battery only. You may purchase the charger separately. It takes approximately 3 hours to charge the battery to full. Note: Battery charging stops when the temperature drops below 0°C or exceeds 40°C. It is recommended to charge the battery at room temperature (18°C to 25°C) for optimal performance. 1) Insert the battery. 2) Lock the battery. 3) Connect the power supply cord to the charger. 4) Connect the other end of the power cord to a suitable power outlet. Enter Setup 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Status LED Meaning Red, solid --- Charger power ON (LED on for 0.5 second) Red, solid --- Charging battery --- Green, solid Charging done Red, solid Green, solid Pre-charging when battery voltage under 3V (Typical) --- --- Power or battery not ready Update 1560/1562 Series Barcode Scanner User Guide INSIDE THE PACKAGE The items included in the package may be different, depending on your order. Save the box and packaging material for future use in case you need to store or ship the scanner. Barcode Scanner (1560, 1560P, or 1562) BT Base (3656 CRADLE) Rechargeable Li-ion battery PRODUCT HIGHLIGHTS Small-form-factor and built tough to survive drop test Extremely low power consumption Firmware upgradeable Supports most popular barcode symbologies, including GS1-128 (EAN-128), GS1 DataBar (RSS), etc. Supports negative barcodes Supports different scan modes, including Aiming Mode and Multi-Barcode Mode User feedback via LED indicator and beeper Beeping tone and duration programmable for Good Read 512 KB flash memory for Memory Mode operation, storing up to 32,768 scans based on EAN-13 barcodes Provides up to 4 KB SRAM for reserve buffer while getting out of range over a wireless personal area network (WPAN), storing up to 256 scans based on EAN-13 barcodes Capable of transmitting scanned data, emulating a serial cable (BT SPP) or as keyboard input (BT HID), to a notebook computer or PDA with Bluetooth® wireless technology Programmable parameters include data output format, editing format, symbologies, etc. Easy configuration through ScanMaster Easy connection through CipherConnect, available via online marketplace for mobile devices running on Android 2.x, BlackBerry 5.x, or Windows Mobile 6.x Enter Setup 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 SYMBOLOGIES SUPPORTED Most of the popular barcode symbologies are supported, as listed below. Each can be individually enabled or disabled. The scanner will automatically discriminate and recognize all the symbologies that are enabled. Refer to Chapter 4 Changing Symbology Settings for details of each symbology. Symbologies Supported: Enable/Disable Default Codabar Enabled Code 93 Enabled MSI Disabled Plessey Disabled Telepen Disabled Code 128 Code 128 Enabled GS1-128 (EAN-128) Enabled ISBT 128 Enabled Note: Starting from firmware version 1.01, ISBT 128 is enabled by default. Code 2 of 5 Industrial 25 Enabled Interleaved 25 Enabled Matrix 25 Code 3 of 9 EAN/UPC Code 39 Disabled Enabled Italian Pharmacode Disabled French Pharmacode Disabled Trioptic Code 39 Disabled EAN-8 Enabled EAN-8 Addon 2 Disabled EAN-8 Addon 5 Disabled EAN-13 Enabled EAN-13 & UPC-A Addon 2 Disabled EAN-13 & UPC-A Addon 5 Disabled ISBN Disabled UPC-E0 Enabled UPC-E1 Disabled UPC-E Addon 2 Disabled UPC-E Addon 5 Disabled UPC-A Enabled Update 1560/1562 Series Barcode Scanner User Guide GS1 DataBar (RSS) GS1 DataBar Omnidirectional (RSS-14) Disabled GS1 DataBar Truncated Disabled GS1 DataBar Stacked Disabled GS1 DataBar Stacked Omnidirectional Disabled GS1 DataBar Limited (RSS Limited) Disabled GS1 DataBar Expanded (RSS Expanded) Disabled GS1 DataBar Expanded Stacked Disabled Disabled Code 11 10 Enter Setup 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 11 Update QUICK START The configuration of the scanner can be done by reading the setup barcodes contained in this manual or via the ScanMaster software. This section describes the procedure of configuring the scanner by reading the setup barcodes and provides some examples for demonstration. Configuration Mode 1. Hold down the trigger about 2 seconds to turn on the scanner. It will respond with a long beep and its LED will come on-off shortly. 2. Have the scanner read the “Enter Setup” barcode. It will respond with six beeps and its LED indicator will become flashing red after reading the barcode. 3. Have the scanner read more setup barcodes… Most of the setup barcodes are normal. The scanner will respond with two beeps (low-high tone). For special setup barcodes, it requires reading more than one setup barcode to complete the setting. 4. Have the scanner read the “Update” or “Abort” barcode. It will respond with six beeps and its LED indicator will become flashing red after reading the barcode. 5. The scanner will restart automatically upon reading the “Update” or “Abort” barcode. It will respond with a long beep and its LED will come on-off shortly. Note: Refer to Appendix II Host Serial Commands for how to configure the 3656 CRADLE stand by having the scanner read 3656 CRADLE -related setup barcodes or using serial commands. 13 Update 1560/1562 Series Barcode Scanner User Guide Working Working Mode Upon powering up, the 1560/1562 scanner will try to establish a connection with 3656 CRADLE or a computer with Bluetooth® wireless technology. Refer to Chapter 3 – Setting up a WPAN Connection for details. The connection between the scanners and 3656 CRADLE is made easy and reliable. Note: If RS-232, USB Virtual COM or BT SPP is selected for output interface, the host can directly send serial commands to configure the scanner. For example, run HyperTerminal.exe and type the 6-digit command located under each setup barcode. Refer to Appendix II Host Serial Commands. 14 Enter Setup 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 ENTER CONFIGURATION MODE For the scanner to enter the configuration mode, you must have it read the “Enter Setup” barcode, which can be located at the bottom of almost every even page of this manual. The scanner will respond with six beeps and its LED indicator will become flashing red after reading the barcode. Enter Setup For configuring scanner parameters, see “Read a Setup Barcode” below. EXIT CONFIGURATION MODE MODE For the scanner to save settings and exit the configuration mode, you must have it read the “Update” barcode, which can be located at the bottom of almost every odd page of this manual. If you want to exit the configuration mode without saving any changes, have the scanner read the “Abort” barcode instead. Just like reading the “Enter Setup” barcode, the scanner will respond with six beeps and its LED indicator will become flashing red after reading the barcode. Wait for a few seconds for the scanner to restart itself. Update Abort 15 Update 1560/1562 Series Barcode Scanner User Guide DEFAULT SETTINGS SAVE USER SETTINGS AS AS DEFAULTS For the scanner to keep the customized settings as user defaults, you must have it read the “Save as User Defaults” barcode. This is a normal setup barcode, and the scanner will respond with two beeps (low-high tone). After reading the “Update” barcode, the current settings will be saved as user defaults. Save as User Defaults RESTORE USER DEFAULTS DEFAULTS For the scanner to restore the user defaults, which you have saved earlier, you must have it read the “Restore User Defaults” barcode. This is a normal setup barcode, and the scanner will respond with two beeps (low-high tone). After reading the “Update” barcode, all the parameters of the scanner will return to their customized values. Restore User Defaults RESTORE SYSTEM DEFAULTS DEFAULTS For the scanner to restore the factory defaults, you must have it read the “Restore System Defaults” barcode. This is a normal setup barcode, and the scanner will respond with two beeps (low-high tone). For 3656 CRADLE to restore factory defaults, refer to 3656 CRADLE Setup Barcodes & Serial Commands. After reading the “Update” barcode, all the parameters of the scanner will return to their default values. The current connection record will be cleared as well. Restore System Defaults Note: The system default value (if there is) for each setting is indicated by an asterisk “*”. 16 Enter Setup 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 READ A SETUP BARCODE CONFIGURE PARAMETERS For most of the scanner parameters, only one read is required to set them to new values. The scanner will respond with two beeps (low-high tone) when each parameter is set successfully. But for a number of special parameters, multiple reads are required to complete the setting. In this case, the scanner will respond with a short beep to indicate it needs to read more setup barcodes. These special parameters may require reading one or more setup barcodes, such as Numeric barcodes, say, for keyboard type, inter-character delay, length qualification Hexadecimal barcodes, say, for character strings as prefix, suffix, etc. When “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to change key status when “Normal Key” is selected for Key Type. To complete the configuration of these special parameters, it requires reading the “Validate” barcode, and the scanner will respond with two beeps (low-high tone) to indicate the input values are validated. 17 Update 1560/1562 Series Barcode Scanner User Guide The example below shows how to save your settings as “User Default” so that you may restore user defaults at a later time: Steps Action Action User Feedback if Successful Power on the scanner… The scanner will respond with a long beep (high tone) and its LED indicator will become solid red and go off quickly. Enter the Configuration Mode… The scanner will respond with six beeps (high-low tone repeats three times), and its LED indicator will be flashing red. Read a Setup barcode… The scanner will respond with two beeps (low-high tone) if reading a normal setup barcode. For example, Exit the Configuration Mode… Same as for Enter the Configuration Mode. OR The scanner will automatically restart itself… Same as for Power on the scanner. When any configuration error occurs... The scanner will respond with one long beep (low tone). 18 Enter Setup 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 The example below shows how to set numeric parameters: Steps Action User Feedback if Successful Power on the scanner... The scanner will respond with a long beep (high tone) and its LED indicator will become solid red and go off quickly. Enter the Configuration Mode… The scanner will respond with six beeps (high-low tone repeats three times), and its LED indicator will become flashing red. Read a Setup barcode... The scanner will respond with two beeps (low-high tone) if reading a normal setup barcode. For example, Normal setup barcode Normal setup barcode The scanner will respond with one short beep if reading a special setup barcode such as “Max. Length”, indicating the setup requires reading more barcodes. Special setup barcode Read the “Decimal Value” barcode(s). Decimal barcodes Refer to System” Appendix IV “Decimal The scanner will respond with two beeps (low-high tone) when the input values are validated. Exit the Configuration Mode… Same as for Enter the Configuration Mode. OR The scanner will automatically restart itself… Same as for Power on the scanner. 19 Update 1560/1562 Series Barcode Scanner User Guide The example below shows how to set string parameters: Steps Action User Feedback if Successful Power on the scanner... The scanner will respond with a long beep (high tone) and its LED indicator will become solid red and go off quickly. Enter the Configuration Mode… The scanner will respond with six beeps (high-low tone repeats three times), and its LED indicator will become flashing red. Read a Setup barcode... The scanner will respond with one short beep if reading a special setup barcode such as “Prefix Code”, indicating the setup requires reading more barcodes. For example, Special setup barcodes When “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to change key status when “Normal Key” is selected for Key Type. Refer to Appendix III Read the “Hexadecimal Value” barcodes for the desired character string. For example, read “2” and “B” for the scanner to prefix the character “+”. Hexadecimal barcodes Refer to Appendix IV “Hexadecimal System” The scanner will respond with two beeps (low-high tone) when the input values are validated. Exit the Configuration Mode… Same as for Enter the Configuration Mode. OR The scanner will automatically restart itself… Same as for Power on the scanner. 20 Enter Setup 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 LIST THE CURRENT SETTINGS SETTINGS The current settings of all scanner parameters can be sent to the host computer for user inspection. The listing includes pages as shown below. You can select the page of interest by having the scanner read the “List Page x” barcode. The scanner will respond with two beeps (low-high tone) and send the selected page to the host immediately. List settings regarding Firmware Version, Serial Number, Interface, Buzzer, and Other Scanner Parameters List settings regarding Prefix, Suffix, and Length Code Setting List Page 1 List Page 2 List settings regarding Code ID List Page 3 List settings regarding: Readable Symbologies List Page 4 List settings regarding Symbology Parameters (1/3) List Page 5 List settings regarding Symbology Parameters (2/3) List Page 6 List settings regarding Symbology Parameters (3/3) List Page 7 List settings regarding Editing Format 1 List Page 8 List settings regarding Editing Format 2 List Page 9 List settings regarding Editing Format 3 List Page 10 21 Update 1560/1562 Series Barcode Scanner User Guide List settings regarding Editing Format 4 List Page 11 List settings regarding Editing Format 5 List Page 12 22 Enter Setup 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 CREATE ONEONE-SCAN SETUP BARCODES The fact is most of the scanner parameters require only one read for setting new values. To facilitate configuring the scanner, you may create One-Scan setup barcodes for use. The requirements of a One-Scan setup barcode are: a prefix of the “#@” characters the six digits of command parameters a suffix of the “#”character For example, the scanner needs reading three setup barcodes for the command parameter “109952” to take effect: Enter Setup List Page 3 Update Now, it requires only one read: One-Scan Setup Barcode for 109952 Note: The scanner will restart automatically upon reading the One-Scan setup barcode for (1) changing the interface or (2) setting memory mode, enable or disable. It will respond with a long beep and its LED will come on-off shortly. 23 Update 1560/1562 Series Barcode Scanner User Guide 24 Enter Setup Chapter 1 UNDERSTANDING NDERSTANDING THE BARCODE SCANNER This chapter will guide you through the features of the barcode scanner and how it can function for you. IN THIS CHAPTER 1.1 Battery ...................................................................... 25 1.2 Memory ..................................................................... 31 1.3 LED Indicator ............................................................. 34 1.4 Beeper....................................................................... 36 1.5 Send “NR” to Host ....................................................... 39 1.6 Scan Modes ................................................................ 40 1.7 Scanning Timeout ....................................................... 45 1.8 Delay between Re-read................................................ 46 1.9 Read Redundancy for All Symblogies ............................. 47 1.10 Addon Security for UPC/EAN Barcodes ......................... 48 1.11 Auto-Sense Mode (1560/1560P Only) .......................... 49 1.12 CCD Sensor Always Active (1560 Only) ........................ 52 1.13 Negative Barcodes..................................................... 52 1.14 Effective Decoding Area ............................................. 53 1.1 BATTERY The scanner is powered by a rechargeable 3.7 V/800 mAh Li-ion battery, and it takes approximately 5 hours to charge the battery to full (via 3656 CRADLE from the power adaptor). However, the charging time may vary by working condition. For intensive data collection, you may need to purchase a spare battery for non-stop operation. Note: See also “Power Economy”, “CCD Sensor Always Active”, “Sniff Mode”, as well as “Low Battery Alarm”. 1.1.1 TURN ON/OFF THE SCANNER Turn on the scanner… scanner… After installing the battery, pull down the trigger for about 2 seconds. The scanner will respond with a long beep (high tone), then the LED will become solid red and go off quickly. Turn off the scanner… scanner… Remove the battery directly or let it turn off automatically in specific circumstances. 25 Update 1560/1562 Series Barcode Scanner User Guide 1.1.2 POWER ECONOMY ECONOMY The scanner features “Power-Saving”, “Auto Power Off” and “Auto Power Off Ignoring Scan Mode” giving consideration to the power issue that is generally critical for Bluetooth-enabled devices. By the scanner’s support of power economy, its power consumption may progress by the following transition: 1) running at full CPU speed at power-on 2) shifting to low CPU speed (Power-Saving) 3) finally shutting down automatically (Auto Power Off) In the following content of this section, you will be guided through the configurations for the scanner’s power economy. 1.1.2.1 POWERPOWER-SAVING For the scanner to save power, you need to appoint the timing for the scanner to shift to power-saving mode. Make the configuration that best suits your application while noting the following points: Power-Saving: 1~254 minutes configurable. 0= Disable. By default, the scanner stands by at full-speed for 2 minutes after power-on and before entering low-speed mode. If Power-Saving isn’t desired, set it to 0 to disable it. Read the setup barcode in the following to achieve the setup. Note: Power-Saving setting won’t take effect when the WPAN connection is established successfully whether via BT HID or SPP. Power-Saving after 0~254 min. (*2) 1) Read the barcode above to enable the scanner to enter low-speed “Power-Saving”. 2) Assign the time for the scanner to enter low-speed mode by reading the “Decimal Value” barcode on page 241. For example, read “5” for the scanner to enter low-speed mode after idleness of 5 minutes. 3) Read the “Validate” barcode on the same page to complete this setting. 26 Enter Setup Chapter 1 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Note: Power-Saving won’t take effect when one of the following conditions is met: (1) the scanner has already established a BT HID/SPP connection, (2) the scanner is in the configuration mode, (3) the scan mode is set to Test, Continuous or Alternate Mode, (4) 1560 is in Auto-Sense mode and seated in the 3656 CRADLE stand, or (5) the setting value of Power-Saving is greater than that of Auto Power Off. 1.1.2.2 AUTO POWER OFF OFF For the scanner to save power, further to setting up “Power-Saving” mode, you may also need to enable “Auto Power Off”, which deals with a time for the scanner to automatically power off after power-on. Make the configuration that best suits your application while noting the following points: Auto Power Off: 1~254 minutes configurable. 0= Disable. 1. By default, the scanner automatically shuts down 10 minutes after power-on. 2. If Auto Power Off isn’t desired, set the parameter to 0 to disable it. 3. When the scan mode is set to any of Continuous Mode, Test Mode, and Alternate Mode, you need to enable “Auto Power Off Ignoring Scan Mode” in addition to enabling “Auto Power Off”. See the following section 1.1.2.3 Auto Power Off Ignoring Scan Mode to achieve auto power off. Note: When the scanner is set to any scan mode other than Continuous Mode, Test Mode and Alternate Mode, you can skip “Auto Power Off Ignoring Scan Mode”. Auto Power Off after 0~254 min. (*10) 1) Read the barcode above to enable the scanner to automatically turn off at a specified time after power-on. 2) Assign the auto power off time by reading the “Decimal Value” barcode on page 241. For example, read “1” and “5” for the scanner to automatically turn off after idleness of 15 minutes. 3) Read the “Validate” barcode on the same page to complete this setting. 27 Update 1560/1562 Series Barcode Scanner User Guide Note: “Auto Power Off” will not take effect when one of the following conditions is met: (1) the scanner is in the configuration mode, or (2) 1560 is in Auto-Sense mode and seated in the 3656 CRADLE stand. 1.1.2.3 AUTO POWER OFF OFF IGNORING SCAN MODE MODE This mode is intended only for Continuous Mode, Test Mode, and Alternate Mode. To force a scanner that is set to one of these three modes to automatically power off to save power, you need the following settings: 1. Enable “Auto Power Off” as detailed in the foregoing section 1.1.2.2 Auto Power Off. And set a time for the scanner to automatically power off after power-on. 2. Enable “Auto Power Off Ignoring Scan Mode” by reading the barcode below: Enable *Disable Read the barcode above to enable/disable automatic power-off for Continuous Mode, Test Mode, and Alternate Mode. Note: “Auto Power Off Ignoring Scan Mode” only features enabling and disabling. It doesn’t feature the setting of auto power-off time. Such setting should be configured in the preceding setup of “Auto Power Off”. 28 Enter Setup Chapter 1 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 1.1.3 1.1.3 POWER ECONOMY VS. WPAN CONNECTION Before the scanner can communicate with the host computer, Bluetooth connection (or WPAN connection) needs to be established. The scanner’s power economy always accommodates itself to the establishment of the WPAN connection. The following describes how the scanner carries out power economy before and after the establishment of the WPAN connection: Before efore establishing a WPAN connection successfully… successfully… 1. The scanner stays active for a specified period of time (2 minutes by default) for the following scenarios. The CPU runs at full speed, and the LED blinks blue (On/Off ratio 0.5 s: 0.5 s). (a) waiting for a connection request from the host (BT SPP Slave Mode) (b) trying to connect to the host (BT HID or BT SPP Master Mode) (c) trying to connect to 3656 CRADLE 2. If the scanner fails to connect within 2 minutes, it becomes inactive to save power for the remaining period of time (the specified “Auto Power Off” value minus 2 minutes). The CPU starts to run at low speed, and the LED begins to blink red (On/Off ratio 0.3 s: 2.5 s). Pull the trigger to wake up the scanner when it becomes inactive, and the scanner will become active again. 3. If it fails to connect again and again, and finally stays inactive until the specified Auto Power Off time elapses, the scanner will automatically turn off in order to conserve battery power. Pull down the trigger for about 2 seconds to turn it on again. Note: For scenarios (a) and (b) in step 1, you may need to search for the scanner again on your computer. After establishing a WPAN connection successfully… successfully… 1. Once a WPAN connection is established successfully, the scanner will stay active for a specified period of time (2 minutes by default) for data transmission. The CPU runs at full speed, and the LED blinks blue (On/Off ratio 0.02 s: 3 s). 2. If the scanner stays idle for 2 minutes (default), it will then turn inactive to save power for the remaining period of time (the specified “Auto Power Off” value minus 2 minutes). The CPU runs at low speed, and the LED is blinking red (On/Off ratio 0.3 s: 2.5 s). Pull the trigger to wake up the scanner when it becomes inactive, then the scanner will stay active again. For BT HID or SPP, the scanner automatically shuts down after the configured “Auto Power Off” time without the transition from full CPU speed to low CPU speed. However, when connecting with 3656 CRADLE, the scanner will go through the transition in order to save power. 3. If the scanner first becomes idle and finally stays inactive until the specified Auto Power Off time is up, the scanner will automatically turn off in order to conserve battery power. You will hear three short beeps, tone descending from high to low. Pull down the trigger for about 2 seconds to turn it on again. For BT HID, the scanner resumes the connection with the host upon powering on again, as long as the host application is running. You will hear three short beeps, tone ascending 29 Update 1560/1562 Series Barcode Scanner User Guide from low to high upon the resumption. If the scanner fails to resume the connection, it will try every 5 seconds to re-connect to the host unless you have the scanner read the “Reset Connection” barcode. For BT SPP Slave Mode, the scanner waits for the host to re-connect. For BT SPP Master Mode, the scanner resumes the connection with the host upon powering on again as long as the host application is running. You will hear three short beeps, tone ascending from low to high upon resumption. If the scanner fails to resume the connection, it will try every 5 seconds to re-connect to the host unless you have the scanner read the “Reset Connection” or “Restore System Defaults” barcode. With the use of 3656 CRADLE, the scanner tries to re-connect 3656 CRADLE unless you turn off the scanner. 30 Enter Setup Chapter 1 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 1.2 MEMORY The collected data can be sent back to a host computer one by one via the WPAN connection or stored in flash memory when the scanner is set to Memory mode. 1.2.1 TRANSMIT BUFFER BUFFER By default, transmit buffer is enabled and for use when the scanner is out of range. Upon reading a barcode successfully within range, the scanner responds with one short beep (high tone) and its LED indicator becomes solid green and goes off quickly. However, the host computer may not receive the data immediately if getting out of range. With the 4 KB transmit buffer, the scanner can ignore the transmission status and keep on reading barcodes until the buffer is full. When transmit buffer is enabled… If the scanner is out of range, it will respond with two short beeps, high-low tone, upon reading a barcode successfully. When transmit buffer is full, the scanner will respond with one long beep (low tone) and its LED indicator will become solid red and go off quickly. You are advised to get back to range. When transmit buffer is disabled… If the scanner is out of range, it will respond with one long beep (low tone) and its LED indicator will become solid red and go off quickly. You are advised to get back to range. *Enable Disable Note: The 4 KB transmit buffer on the scanner can hold as many as 256 scans based on EAN-13 barcodes. Data will be cleared out once the scanner is turned off or running out of battery power! 31 Update 1560/1562 Series Barcode Scanner User Guide 1.2.2 1.2.2 MEMORY MODE The scanner keeps 512 KB flash memory for memory mode operation. When the scanner is in memory mode, it means any real-time connection established with the host is disabled. Enable *Disable Warning: No real-time connection is allowed unless the memory mode is disabled. Memory Data Delay You may set a delay between each data record while transmitting data back to the host. *None 250 ms 500 ms 1 sec 2 sec 3 sec 5 sec 32 Enter Setup Chapter 1 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 8 sec Send Data The 512 KB flash memory on the scanner can store up to 32,768 scans based on EAN-13 barcodes. When it is used up, the scanner will respond with two short beeps (high-low tone) as a warning. You are advised to send data to the host immediately by having the scanner read the “Send Data” barcode below. It will resume the previous WPAN connection with the host temporarily. Send Data Clear Data & Confirm Even though data has been sent back to the host, the flash memory is still occupied unless you erase the memory by having the scanner read two barcodes – “Clear Data” and “Confirm”. 1. Read the “Clear Data” barcode to clear the flash memory. 2. Read the “Confirm” barcode to confirm the action. Clear Data Confirm 1.2.3 FREE MEMORY In memory mode, you can scan the barcode below to show the available capacity of the flash memory in percentage terms. Spare memory 33 Update 1560/1562 Series Barcode Scanner User Guide 1.3 LED INDICATOR The triple-color LED on top of the scanner is used to provide user feedback. For example, the LED becomes solid red and goes off quickly upon powering on or running out of transmit buffer. You may tell the difference by the beeps – you will hear a long beep of high tone when powering on the scanner, and a long beep of low tone when the transmit buffer becomes full. Scanner LED Meaning --- Charging (On/Off ratio 0.5 s: 0.5 s) Red, flashing --- Red, solid --- --- Charging error Red, flashing --- --- Flashing red (On/Off ratio 0.3 s: 2.5 s) indicates the scanner is inactive and its CPU running at low speed to save power — Configuration Mode (On/Off ratio 0.5 s: 0.5 s) No WPAN connection is established after waiting for two minutes Red, on-off --- --- Power on, with one long beep (high tone, LED on for 1 second) Data saved to buffer when transmit buffer is enabled and the scanner is out of range, with two short beeps (high-low tone) Transmit buffer full, with one long beep (low tone) Transmit buffer disabled, with one long beep (low tone) Memory full in memory mode, with two short beeps (high-low tone) --- --- Green, on-off Good Read, with one short beep (high tone) and beeper pitch and duration programmable --- Blue, flashing --- First, flashing blue (On/Off ratio 0.5 s: 0.5 s) for two minutes indicates the scanner is waiting for connection, and goes off if no connection is established, then flashing red (On/Off ratio 0.3 s: 2.5 s) indicates the scanner is inactive. It is ready for connection only while the LED is flashing blue — SPP Slave: waiting host to connect HID or SPP Master: trying to connect to host Using 3656 CRADLE: trying to connect to 3656 CRADLE --- Blue, flashing --- Flashing blue (On/Off ratio 0.1 s: 0.1 s) indicates the scanner receives a PIN code request from host (flashing more quickly than waiting connection). --- Blue, flashing --- Flashing blue (On/Off ratio 0.02 s: 3 s) indicates the scanner has established a WPAN connection successfully. --- Blue, flashing Green, flashing Flashing blue and green (On/Off ratio 0.1 s: 0.1 s) indicates an error occurs while entering the PIN code. Press the trigger to get ready for re-connecting. 34 Enter Setup Chapter 1 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字 套用到您想要在此處顯示的文字。 示的文字。 1.3.1 1.3.1 GOOD READ LED *Enable Good Read LED Disable Good Read LED 1.3.2 GOOD READ LED DURATION By default, the Good Read LED stays on for 40 milliseconds. Specify a value, ranging from 1 to 254 in units of 10 milliseconds. Good Read LED Time-out after 0.01~2.54 sec. (*40 ms) 1) Read the barcode above to specify the time interval before the Good Read LED goes off. 2) Read the “Decimal Value” barcode on page 241. For example, read “1” and “5” for the Good Read LED to go off after 150 milliseconds. 3) Read the “Validate” barcode on the same page to complete this setting. 35 Update 1560/1562 Series Barcode Scanner User Guide 1.4 1.4 BEEPER BEEPER The scanner has a buzzer to provide user feedback in various operating conditions. Beeping Meaning One long beep, high tone Power on, with red LED on (1 second) and off quickly One short beep, high tone Good Read, with green LED on-off quickly Programmable, default to 4 KHz Enter Configuration Mode, with red LED flashing Six short beeps High-low times tone repeats three Two short beeps, low-high tone One short beep, high tone Exit Configuration Mode Setup barcode read successfully More setup barcode required Input PIN code Clear PIN code One short beep, low tone One long beep, low tone More barcodes required to complete the “output sequence” requirements of Multi-Barcode Editor, with green LED on-off quickly (Upon completion, same as Good Read.) Transmit buffer full, with red LED on-off quickly Transmit buffer disabled, with red LED on-off quickly Configuration error (Wrong barcode…) PIN code input error Reject random PIN request Fail to send data in memory mode Two short beeps, high-low tone Data saved to buffer when transmit buffer is enabled and the scanner is out of range, with red LED on-off quickly Memory Mode – Memory full, with red LED on-off quickly Two short beeps, high tone Low Battery Alarm Two long beeps, high-low tone Multi-Barcode Mode – Buffer full Three short beeps, tone ascending from low to high Three short beeps, tone ascending from high to low WPAN connection established, with blue LED flashing WPAN connection resumed, with blue LED flashing WPAN connection out of range or suspended 36 Enter Setup Chapter 1 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 1.4.1 1.4.1 BEEPER VOLUME Mute Minimum Volume Medium Volume *Maximum Volume 37 Update 1560/1562 Series Barcode Scanner User Guide 1.4.2 1.4.2 GOOD READ BEEP Frequency 8 kHz *4 kHz 2 kHz 1 kHz Duration *Shortest Shorter Longer Longest 38 Enter Setup Chapter 1 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 1.4.3 1.4.3 LOW BATTERY ALARM By default, it will activate the beeper to give a warning when the battery charge gets low. In order to prevent data loss, you are advised to replace the battery immediately when you hear two short beeps (high tone). No Alarm *Low Battery Alarm 1.5 SEND “NR” TO HOST The scanner can send the “NR” string to the host to notify the No Read event. Enable *Disable 39 Update 1560/1562 Series Barcode Scanner User Guide 1.6 1.6 SCAN MODES Different scan modes are supported – select the scan mode that best suits the requirements of a specific application. Refer to the comparison table below. Scan Mode Start to Scan Always Press trigger once Stop Scanning Hold trigger Press trigger twice Release trigger Press trigger once Continuous mode Test mode Laser mode Auto Off mode Auto Power Off mode Alternate mode Aiming mode Multi-Barcode mode Note: By default, the scan mode is set to Laser mode. 40 Enter Setup Barcode being read Timeout Chapter 1 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 1.6 1.6.1 CONTINUOUS MODE The scanner is always scanning. After a successful decoding, the removal of barcode is required. It is not allowed to proceed to decode until the decoding delay time has passed. To decode the same barcode repeatedly, move away the barcode and put it back again and again for scanning. Note: Refer to “Delay between Re-read”. Continuous Mode Decoding Delay Set the time interval between each decoding. *Disable 0.5 sec 1 sec 2 sec 1.6 1.6.2 TEST MODE The scanner is always scanning. Capable of decoding the same barcode repeatedly without removing it, for testing purpose. Test Mode 41 Update 1560/1562 Series Barcode Scanner User Guide 1.6 1.6.3 LASER MODE The scanner will start scanning once the trigger is held down. The scanning won’t stop until (1) a barcode is decoded, (2) the pre-set timeout expires, or (3) you release the trigger. Note: Refer to “Scanning Timeout”. *Laser Mode 1.6 1.6.4 AUTO OFF MODE The scanner will start scanning once the trigger is pressed. The scanning won’t stop until (1) a barcode is decoded, and (2) the pre-set timeout expires. Note: Refer to “Scanning Timeout”. Auto Off Mode 1.6. 1.6.5 6.5 AUTO POWER OFF MODE The scanner will start scanning once the trigger is pressed. The scanning won’t stop until the pre-set timeout expires, and, the pre-set timeout period re-counts after each successful decoding. Note: Refer to “Delay between Re-read” and “Scanning Timeout”. Auto Power Off Mode 42 Enter Setup Chapter 1 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 1.6.6 ALTERNATE MODE The scanner will start scanning once the trigger is pressed The scanning won't stop until you press the trigger again. Alternate Mode 1.6 1.6.7 AIMING MODE The scanner will aim at a barcode once the trigger is pressed, and start scanning when the trigger is pressed again within one second. The scanning won't stop until (1) a barcode is decoded, and (2) the pre-set timeout expires. Aiming Mode Aiming Timeout You can limit the aiming time interval (1~15). By default, the scanner time-out is set to 1 second. Aiming Time-out after 1~15 sec. (*1) 1. Read the barcode above to specify the time interval before aiming ends. (It is set to 1 by default.) 2. Read the “Decimal Value” barcode on page 241. For example, read “1” and “0” for the scanner to automatically shut down after idleness for 10 seconds. 3. Read the “Validate” barcode on the same page to complete this setting. 43 Update 1560/1562 Series Barcode Scanner User Guide 1.6 1.6.8 MULTIMULTI-BARCODE MODE The scanner will be scanning as long as the trigger is held down, capable of decoding one single barcode, as well as multiple unique barcodes one at a time. While decoding a bunch of unique barcodes, if a barcode is decoded twice, its subsequent decoding will be ignored and the scanner is expecting another unique barcode. The scanning won't stop until you release the trigger. Multi-Barcode Mode Note: (1) A barcode is considered unique when its Code Type or data is different from others. (2) Multi-Barcode Mode has nothing to do with the Multi-Barcode Editor. 44 Enter Setup Chapter 1 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 1.7 1.7 SCANNING SCANNING TIMEOUT Specify the scanning time interval (1~254 sec.; 0= Disable) when the scan mode is set to any of the following – Laser mode Auto Off mode Auto Power Off mode Aiming mode Scanner Time-out after 0~254 sec. (*10) 1) Read the barcode above to specify the time interval before the scan engine times out. 2) Read the “Decimal Value” barcode on page 241. For example, read “1” and “5” for the scanner to automatically shut down after idleness of 15 seconds. 3) Read the “Validate” barcode on the same page to complete this setting. 45 Update 1560/1562 Series Barcode Scanner User Guide 1.8 1.8 DELAY BETWEEN RERE-READ This is also referred to as the “Blocking Time”, which is used to prevent the scanner from accidentally reading the same barcode twice when the scan mode is set to any of the following – Continuous mode Auto Power Off mode Alternate mode 100 ms 200 ms *400 ms 800 ms 1 sec 2 sec 3 sec 5 sec 46 Enter Setup Chapter 1 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 1.9 1.9 READ REDUNDANCY REDUNDANCY FOR ALL SYMBLOGIES SYMBLOGIES Select the level of reading security. For example, If “No Redundancy” is selected, one successful decoding will make the reading valid and induce the “READER Event”. If “Three Times” is selected, it will take a total of four consecutive successful decoding of the same barcode to make the reading valid. The higher the reading security is (that is, the more redundancy the user selects), the slower the reading speed gets. It is obvious that the more redundancy you select, the higher the reading security is, and thus, the slower the reading speed becomes. You will have to compromise between reading security and decoding speed. *No Redundancy One Time Two Times Three Times 47 Update 1560/1562 Series Barcode Scanner User Guide 1.10 1.10 ADDON SECURITY FOR UPC/EAN BARCODES The scanner is capable of decoding a mix of UPC/EAN barcodes with and without addons. The read redundancy (0~30 times) allows changing the number of times to decode a UPC/EAN barcode before transmission. The more redundancy you select, the higher the reading security is, and thus, the slower the reading speed becomes. You will have to compromise between reading security and decoding speed. Note: UPC/EAN Addon 2 and Addon 5 must be enabled individually for this setting to take effect. Addon Security Level (*0~30) 1) Read the barcode above to specify the read redundancy for UPC/EAN barcodes. (It is set to 0 by default.) 2) Read the “Decimal Value” barcode on page 241. For example, read “1” and “2” for the scanner to re-read the barcode for 12 times. 3) Read the “Validate” barcode on the same page to complete this setting. 48 Enter Setup Chapter 1 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 1.11 AUTOAUTO-SENSE MODE (1560/1560P (1560/1560P ONLY) 1.11.1 BEHAVIOR OF 1560 1560 For 1560, this mode is available when you seat the scanner in the Auto-sense stand and scan the Enable barcode. When you enable this mode, it will force the scanner to apply Laser mode as the scan mode. However, it works slightly different from the original Laser mode. Now the scanner will be expecting barcodes as long as it is seated in the Auto-sense stand, as shown below. Whenever a barcode is brought within range, the scanner will be able to decode it. Enable *Disable Note: Enabling Auto-sense will force the scanner into Laser mode. To stop this mode, you may remove the scanner from the stand or have the scanner read the “Disable (Auto-sense)” barcode above. It will then return to Laser mode. If Laser mode is not desired, proceed to select a scan mode best suits your application. Note: To get Auto-sense mode work, you must connect both the power supply cord and the interface cable to the stand; supplying the only USB power is insufficient. 49 Update 1560/1562 Series Barcode Scanner User Guide 1.11.2 BEHAVIOR OF 1560P 1560P For 1560P, Auto-sense is only available when the scanner is working in Laser Mode. 1560P will be expecting barcodes as long as it is seated in the Auto-sense stand. Whenever a barcode is brought within range, the scanner will be able to decode it. To stop this mode, just remove the scanner from the stand. *Enable Disable You can determine the occasion for decoding destination barcodes. As the setting barcodes shown below, “Detection By Barcode” means when an object is judged a barcode, the scanner decodes the destination barcode. “Detection by Motion” means when an object is detected moving, the scanner decodes the destination barcode. *Detection By Barcode Detection By Motion Besides, users can determine the auto-sense detection level ranging from 0 to 7 (default value is set to 4; greater number means higher detection sensitivity) when the scanner is seated in the stand and set in the “Detection By Motion” mode. Auto-sense Detection Level 0~7 (*4) 1) Read the barcode above to specify the Auto-sense Detection level. 2) Read the “Decimal Value” barcode on page 241. For example, read “1” to set the Auto-sense Detection Level on 1. 3) Read the “Validate” barcode on the same page to complete this setting. 50 Enter Setup Chapter 1 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 For your convenience, 1560P is designed to power on automatically in Auto-sense mode when you seat it in the stand connecting to the power socket. By default, this mechanism is disabled. You have to enable it by having the scanner read the Enable barcode below. Enable *Disable 1.11.3 AMBIENT LIGHT When the ambient light is too dim to activate the sensor, you may have the scanner read the “High Sensitivity” barcode to improve performance. Starting from firmware version 1.23, it will emit scan beam every 300 milliseconds when “High Sensitivity” is enabled. High Sensitivity *Normal Note: If the ambient light is under 100 lux, we suggest that you either add lighting or use Continuous mode instead. 51 Update 1560/1562 Series Barcode Scanner User Guide 1.12 CCD SENSOR ALWAYS ALWAYS ACTIVE ACTIVE (1560 ONLY) This feature is used to keep the CCD sensor always active so that the scanner can decode more efficiently. However, you may disable it in order to save battery power. *Enable Disable 1.13 1.13 NEGATIVE BARCODES Normally, barcodes are printed with the color of the bars darker than that of the spaces. But for negative barcodes, they are printed in the opposite sense just like negative films. The spaces of negative barcodes are printed with a color darker than that of the bars. You can configure the scanner to be able to read negative barcodes. Enable *Disable 52 Enter Setup Chapter 1 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 1.14 1.14 EFFECTIVE DECODING AREA AREA By default, the effective decoding area is 100% covered by the scanned area. However, you may narrow down the decoding area to prevent reading the wrong barcode when a number of barcodes are printed closely. The scanner will only read barcodes that appear in the effective decoding area. Read the barcode “Centering On” and specify the percentage to narrow down the decoding area. For example, read “Left 10%” and then “Right 30%” for the scanner to decode barcode “A” only. 1.14 1.14.1 WINDOW 14.1 POSITIONING WINDOW Centering On *Centering Off 53 Update 1560/1562 Series Barcode Scanner User Guide 1.14 1.14.2 14.2 ADJUSTING WINDOW Percentage for Left Half *Left 50% Left 40% Left 30% Left 20% Left 10% Percentage for Right Half Right 10% Right 20% Right 30% Right 40% *Right 50% 54 Enter Setup Chapter 2 SELECTING SELECTING OUTPUT INTERFACE INTERFACE In order to establish a proper connection between your computer and the scanner, we suggest that you follow these instructions – 1) Install the battery and hold down the trigger for about 2 seconds to turn on the scanner. 2) Have the scanner read the “Enter Setup” barcode to enter the configuration mode. 3) Have the scanner read the associated barcodes to activate the desired interface. See the following sections for output interfaces supported. 4) Have the scanner read the barcodes for related settings. 5) Have the scanner read the “Update” barcode to exit the configuration mode. 6) Turn on your computer or laptop and establish a WPAN connection with the scanner. Refer to Chapter 3 – Setting up a WPAN Connection. Note: By default, the output interface is set to “BT HID”. IN THIS CHAPTER 2.1 2.2 2.3 2.4 2.5 2.6 2.7 BT HID ...................................................................... 56 BT SPP Slave .............................................................. 68 BT SPP Master ............................................................ 72 Keyboard Wedge via .................................................. 77 RS-232 via ............................................................... 88 USB HID via .............................................................. 93 USB Virtual COM via ................................................ 103 55 Update 1560/1562 Series Barcode Scanner User Guide 2.1 2.1 BT HID For BT HID, refer to Chapter 3 – Setting up a WPAN Connection for related connection settings. Run any text editor on your computer, and the scanned data will be transmitted to the computer. HID Settings Defaults Keyboard Type PCAT (US) Alphabets Layout Normal Digits Layout Normal Capital Lock Type Normal Capital Lock State Off Alphabets Transmission Case-sensitive Digits Transmission Alphanumeric keypad Inter-Character Delay 0 (ms) Inter-Function Delay 0 (ms) 56 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 2.1.1 .1.1 ACTIVATE BT HID & SELECT KEYBOARD KEYBOARD TYPE When BT HID interface is activated, you will have to select a keyboard type to complete this setting. By default, BT HID is activated on the scanner, and the keyboard type is set to PCAT (US). Activate BT HID & Select Keyboard Type… 1) Read the barcode above to activate BT HID and select a keyboard type. 2) Read the “Decimal Value” barcode on page 241. Refer to the table below for the number of desired keyboard type. 3) Read the “Validate” barcode on the same page to complete this setting. BT HID By default, the keyboard type is set to PCAT (US). The following keyboard types are supported — No. Keyboard Type No. Keyboard Type 64 PCAT (US) 72 PCAT (Spanish) 65 PCAT (French) 73 PCAT (Portuguese) 66 PCAT (German) 74 PS55 A01-2 (Japanese) 67 PCAT (Italy) 75 User-defined table 68 PCAT (Swedish) 76 PCAT (Turkish) 69 PCAT (Norwegian) 77 PCAT (Hungarian) 70 PCAT (UK) 78 PCAT (Swiss German) 71 PCAT (Belgium) 79 PCAT (Danish) 57 Update 1560/1562 Series Barcode Scanner User Guide 2.1.2 RESET CONNECTION For BT HID, you can only have the scanner connected to one computer at a time. If you want to connect the scanner to another host, you must have it read the “Reset Connection” barcode so that the current connection record will be cleared. Then, the scanner will restart itself automatically. Go through the whole process in 3.2.3 Connect to Dongle to establish a new connection. Reset Connection Note: The “Restore System Defaults” barcode will have the current connection record cleared as well. 58 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 2.1 2.1.3 KEYBOARD SETTINGS Alphabets Layout Digits Layout Capital Lock Type Capital Lock Setting Alphabets Transmission Digits Transmission Note: BT HID does not support these functions on PDAs – (1) Capital Lock Setting: Auto Detection (2) Digits Transmission: Numeric Key Alphabets Layout By default, the alphabets layout is set to normal mode, also known as the standard English layout. Select French or German keyboard layout if necessary. The scanner will make adjustments when sending the "A", "Q", "W", "Z", "Y", and "M" characters according to this setting. *Normal AZERTY QWERTZ Note: This setting only works when the keyboard type selected is US keyboard, such as PCAT (US). The Alphabets Layout and Digits Layout setting must match your keyboard. 59 Update 1560/1562 Series Barcode Scanner User Guide US Keyboard Style – Normal QWERTY layout, which is normally used in western countries. Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters. French Keyboard Style – AZERTY French layout; see below for French Keyboard Style. Select “Upper Row” for the “Digits Layout” setting for the lower row is for special characters. German Keyboard Layout – QWERTZ German layout; see below for German Keyboard Style. Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters. 60 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Digits Layout Select a proper layout that matches the alphabets layout. The scanner will make adjustments according to this setting. Options Description Normal Depends on the [Shift] key or [Shift Lock] setting Lower Row For QWERTY or QWERTZ keyboard Upper Row For AZERTY keyboard *Normal Upper Row Lower Row Note: This setting is to be used with the Character Substitution setting when support to certain keyboard types (languages) is unavailable but required. 61 Update 1560/1562 Series Barcode Scanner User Guide Capital Lock Type & Setting In order to send the alphabets with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabets being transmitted. Cap Lock Type Type Description Normal Normal type Capital Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys. Shift Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. In addition, this affects the number or punctuation keys. *Normal Shift Lock Capital Lock Capital Lock State Description Capital Lock OFF Assuming that the status of Caps Lock on the keyboard is OFF, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Capital Lock ON Assuming that the status of Caps Lock on the keyboard is ON, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Refer to the Capital Lock Type above. Auto Detection The scanner will automatically detect the status of Caps Lock on the keyboard before data is transmitted; transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). This setting is not supported on PDAs. Auto Detect Capital Lock ON 62 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 *Capital Lock OFF 63 Update 1560/1562 Series Barcode Scanner User Guide Alphabets Transmission By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabets transmitted according to the status of Caps Lock on the keyboard only. Ignore Case *Case-sensitive Refer to 5.1 Letter Case. 64 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Digits Transmission By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if you wish to use the keys on the numeric keypad. Numeric Key *Alphanumeric Key Note: If you select “Numeric Keypad”, the Num Lock status of the physical keyboard should be “ON”. This setting is not supported on PDAs. 65 Update 1560/1562 Series Barcode Scanner User Guide 2.1.4 INTERINTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Character Delay… (*0~254) 1) Read the barcode above to specify the inter-character delay. 2) Read the “Decimal Value” barcode on page 241 for the desired inter-character delay (millisecond). 3) Read the “Validate” barcode on the same page to complete this setting. 2.1 2.1.5 INTERINTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Function Delay… (*0~254) 1) Read the barcode above to specify the inter-function delay. 2) Read the “Decimal Value” barcode on page 241 for the desired inter-function delay (millisecond). 3) Read the “Validate” barcode on the same page to complete this setting. 66 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 2.1. 2.1.6 1.6 HID CHARACTER TRANSMIT TRANSMIT MODE By default, HID interface sends data to the host character by character. You may have the scanner read the “Batch Processing” barcode to process data in batch. Batch Processing *By Character Note: “By Character” transmit mode is required when working with iPhone or iPad. 67 Update 1560/1562 Series Barcode Scanner User Guide 2.1.7 2.1.7 KEYPAD SUPPORT FOR IPHONE/IPAD IPHONE/IPAD When the scanner has been successfully connected to iPhone or iPad for data collection, the onscreen keypad of iPhone/iPad will disappear by default. Have the scanner read the “Show or Hide Keypad” barcode to show or hide the keypad if necessary. Show or Hide Keypad For 1560P Series scanners, read the “Use Trigger Key to Show or Hide Keypad” barcode in advance allowing users to press the trigger key twice within 0.5 seconds to show or hide the onscreen keypad. Disable *Use Trigger Key to Show or Hide Keypad Note: This function only works for (1) iPhone 4 and 3GS version 4.1 or later, and (2) iPad version 4.2 or later. 2.1.8 TRANSMIT SPEED By default, the BT HID transmit speed is set to Fast for working in quicker transmit speed. Users can have the scanner work in normal speed by reading the Normal barcode. Normal *Fast 2.1.9 BT HID SLAVE/MASTER SLAVE/MASTER SWITCHING By default, the BT HID role is set to slave. Users can have the scanner switch between slave and master by reading the barcodes below. *Slave 68 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Master 2.1.10 BT HID AUTOAUTO-RECONNECTION (1560P ONLY) Users can decide whether to have the scanner automatically reconnect to a paired device after disconnection, and the occasion for reconnecting. *Auto reconnect immediately Auto reconnect on data being scanned Auto reconnect off 69 Update 1560/1562 Series Barcode Scanner User Guide 2.2 2.2 BT SPP SLAVE For BT SPP Slave, refer to Chapter 3 – Setting up a WPAN Connection for related connection settings. 2.2 2.2.1 ACTIVATE BT SPP SLAVE MODE This is SPP Slave Mode. Activate BT SPP, Slave Mode 2.2 2.2.2 INTERINTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Function Delay… (*0~254) 1) Read the barcode above to specify the inter-function delay. 2) Read the “Decimal Value” barcode on page 241 for the desired inter-function delay (millisecond). 3) Read the “Validate” barcode on the same page to complete this setting. 70 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 2.2 2.2.3 ACK/NAK TIMEOUT TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all three attempts fail without any notification, data loss will occur. ACK/NAK Time-out after … (*0~99) 1) Read the barcode above to specify the time interval for the scanner to send data and wait for a response from the host. 2) Read the “Decimal Value” barcode on page 241. For example, read “1” and “0” for the scanner to automatically shut down after idleness of 1 second. 3) Read the “Validate” barcode on the same page to complete this setting. ACK/NAK Error Beep Enable Error Beep *Disable Error Beep Note: We suggest enabling the error beep so that you will be notified of such data loss and have the scanner re-read data. 2.2.4 BT SPP SLAVE HARDWARE HARDWARE FLOW CONTROL By default, the data sending via Bluetooth SPP doesn’t employ hardware flow control. In some cases users may want to enable hardware flow control to prevent data loss during transmission. Please scan the barcode below to enable/disable it. *Disable Enable 71 Update 1560/1562 Series Barcode Scanner User Guide 2.3 BT SPP MASTER As a SPP master device, the scanner will be able to resume connection with the host upon powering on again, as long as the host application is running. If the scanner fails to resume connection, it will try every 5 seconds to re-connect to the host unless you have the scanner read the “Reset Connection” or “Restore System Defaults” barcode. For BT SPP Master, refer 3.2.2 Configure Related Settings for related connection settings. Note: In SPP Master Mode, if the scanner fails to re-connect within the specified period of time (2 minutes by default), the scanner will become inactive to save power. Once the re-connection is established successfully, the scanner will not go through transition from full CPU speed to low CPU speed even though it is idle during the specified time interval for Auto Power Off. It will automatically turn off when the time is up. Refer to 1.1.3 Power Economy vs. WPAN Connection. 2.3 2.3.1 ACTIVATE BT SPP MASTER MODE This is SPP Master Mode. Activate BT SPP, Master Mode How to connect with the target device? Produce two setup barcodes for the target SPP slave device, just like what we do for 3656 CRADLE. “Set Connection” “MAC ID” Note: The “MAC ID” barcode must have a prefix of two characters, either “0x” or “0X”, followed by the real MAC address of the target device. Usage: 1. Read the “Activate BT SPP, Master Mode” barcode above and barcodes for connection settings, such as authentication and preset PIN. Skip this step if no connection settings are desired. 2. Read the “Set Connection” and “MAC ID” barcodes. The scanner will respond with one beep upon reading each of the barcodes. Set Connection Prefix “0X” to target MAC address 72 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Note: Read the “Set Connection” barcode first, and then the “MAC ID” barcode within 10 seconds. Instead of producing the “MAC ID” barcode, you may have the scanner read the setup barcodes for entering the MAC address. Have the scanner read the “Abort” barcode to cancel the operation at any time while reading setup barcodes for the MAC address. If the MAC address has not been completed yet, having the scanner read the “Validate” barcode can cancel the operation as well. Enter MAC ID in Hexadecimal… Usage: 1) Read the barcode above. 2) Read the “Hexadecimal System” barcode on page 242 for the desired MAC address. 3) Read the “Validate” barcode on the same page to complete this setting. Connect with the target device by scanning a single 1D setting barcode Users can produce a single 1D setup barcode that combines the “Set Connection” and “MAC ID” setup commands to connect with the target device. While producing the barcode, be aware the letter upper/lower case “SeTcOn” and the barcode must be the Code 128 symbology. Usage: 1) Read the “Activate Bluetooth® SPP, Master Mode” barcode above and barcodes for connection settings, such as authentication and preset PIN. Skip this step if no connection settings are desired. 2) Read the “SeTcOnxxxxxxxxxxxx” 1D single barcode below. The scanner will respond with one beep upon reading the barcode. Exit SPP Master Mode To stop such re-connection, read “Reset Connection” or “Restore System Defaults” barcode so that the current connection record (= MAC ID) will be cleared. Then, the scanner will restart itself automatically. Go through the process in 3.2.3 Connect to Dongle to establish a new WPAN connection. Reset Connection 73 Update 1560/1562 Series Barcode Scanner User Guide 2.3 2.3.2 INTERINTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Function Delay… (*0~254) 1) Read the barcode above to specify the inter-function delay. 2) Read the “Decimal Value” barcode on page 241 for the desired inter-function delay (millisecond). 3) Read the “Validate” barcode on the same page to complete this setting. 2.3 2.3.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all three attempts fail without any notification, data loss will occur. ACK/NAK Time-out after … (*0~99) 1) Read the barcode above to specify the time interval for the scanner to send data and wait for a response from the host. 2) Read the “Decimal Value” barcode on page 241. For example, read “1” and “0” for the scanner to automatically shut down after idleness of 1 second. 3) Read the “Validate” barcode on the same page to complete this setting. 74 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 ACK/NAK Error Beep Enable Error Beep *Disable Error Beep Note: We suggest enabling the error beep so that you will be notified of such data loss and have the scanner re-read data. 75 Update 1560/1562 Series Barcode Scanner User Guide 2.3.4 SWITCH BETWEEN MASTER/SLAVE MODE After the scanner has established a connection as a SPP slave device, you may have it read the “Activate BT SPP, Master Mode” setup barcode to switch to SPP Master Mode. This will result in easy and reliable re-connection, just like connecting with 3656 CRADLE. 2.3.5 BT SPP MASTER HARDWARE FLOW CONTROL CONTROL By default, the data sending via Bluetooth SPP doesn’t employ hardware flow control. In some cases users may want to enable hardware flow control to prevent data loss during transmission. Please scan the barcode below to enable/disable it. *Disable Enable 2.3.6 BT SPP MASTER AUTOAUTO-RECONNECTION (1560P ONLY) Users can decide whether to have the scanner automatically reconnect to a paired device after disconnection, and the occasion for reconnecting. *Auto reconnect immediately Auto reconnect on data being scanned Auto reconnect off 76 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 2.4 KEYBOARD WEDGE VIA 3656 CRADLE The Y cable allows you to connect the scanner via 3656 CRADLE to the keyboard input port of PC and you may join the keyboard as well. The scanned data will be transmitted to the host keyboard port as if it is manually entered via the keyboard. For example, run a text editor on your computer to receive the data. Keyboard Wedge Settings Defaults Keyboard Type PCAT (US) Alphabets Layout Normal Digits Layout Normal Capital Lock Type Normal Capital Lock State Off Alphabets Transmission Case-sensitive Digits Transmission Alphanumeric keypad Alternate Composing No Laptop Support Disable Inter-Character Delay 0 (ms) Inter-Function Delay 0 (ms) 77 Update 1560/1562 Series Barcode Scanner User Guide 2.4 2.4.1 ACTIVATE KEYBOARD WEDGE & SELECT KEYBOARD KEYBOARD TYPE When Keyboard Wedge interface is activated, you will have to select a keyboard type to complete this setting. Activate 3656 CRADLE Keyboard Wedge & Select Keyboard Type… 1) Read this barcode above to activate Keyboard Wedge and select a keyboard type. 2) Read the “Decimal Value” barcode on page 241. Refer to the table below for the number of desired keyboard type. 3) Read the “Validate” barcode on the same page to complete this setting. Keyboard Wedge via 3656 CRADLE By default, the keyboard type is set to PCAT (US). The following keyboard types are supported when using 3656 CRADLE with the keyboard wedge cable provided — No. Keyboard Type No. Keyboard Type PCAT (US) 18 PS55 001-3 PCAT (French) 19 PS55 001-8A PCAT (German) 20 PS55 002-1, 003-1 PCAT (Italian) 21 PS55 002-81, 003-81 PCAT (Swedish) 22 PS55 002-2, 003-2 PCAT (Norwegian) 23 PS55 002-82, 003-82 PCAT (UK) 24 PS55 002-3, 003-3 PCAT (Belgium) 25 PS55 002-8A, 003-8A PCAT (Spanish) 26 IBM 3477 Type 4 (Japanese) 10 PCAT (Portuguese) 27 PS2-30 11 PS55 A01-1 28 IBM 34XX/319X, Memorex Telex 122 Keys 12 PS55 A01-2 (Japanese) 29 User-defined table 13 PS55 A01-3 30 PCAT (Turkish) 14 PS55 001-1 31 PCAT (Hungarian) 15 PS55 001-81 32 PCAT (Swiss German) 16 PS55 001-2 33 PCAT (Danish) 17 PS55 001-82 78 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 2.4 2.4.2 KEYBOARD SETTINGS Alphabets Layout Digits Layout Capital Lock Type Capital Lock Setting Alphabets Transmission Digits Transmission Alternate Composing Laptop Support Alphabets Layout By default, the alphabets layout is set to normal mode, also known as the standard English layout. Select French or German keyboard layout if necessary. The scanner will make adjustments when sending the "A", "Q", "W", "Z", "Y", and "M" characters according to this setting. *Normal AZERTY QWERTZ Note: This setting only works when the keyboard type selected is US keyboard, such as PCAT (US). The Alphabets Layout and Digits Layout setting must match your keyboard. 79 Update 1560/1562 Series Barcode Scanner User Guide US Keyboard Style – Normal QWERTY layout, which is normally used in western countries. Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters. French Keyboard Style – AZERTY French layout; see below for French Keyboard Style. Select “Upper Row” for the “Digits Layout” setting for the lower row is for special characters. German Keyboard Layout – QWERTZ German layout; see below for German Keyboard Style. Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters. 80 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Digits Layout Select a proper layout that matches the alphabets layout. The scanner will make adjustments according to this setting. Options Description Normal Depends on the [Shift] key or [Shift Lock] setting Lower Row For QWERTY or QWERTZ keyboard Upper Row For AZERTY keyboard *Normal Upper Row Lower Row Note: This setting is meant to be used with the Alphabets Layout; and perhaps with the Character Substitution setting when support to certain keyboard types (languages) is unavailable but required. 81 Update 1560/1562 Series Barcode Scanner User Guide Capital Lock Type & Setting In order to send the alphabets with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabets being transmitted. Cap Lock Type Description Normal Normal type Capital Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys. Shift Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. In addition, this affects the number or punctuation keys. *Normal Shift Lock Capital Lock Capital Lock State Description Capital Lock OFF Assuming that the status of Caps Lock on the keyboard is OFF, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Capital Lock ON Assuming that the status of Caps Lock on the keyboard is ON, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Refer to the Capital Lock Type above. Auto Detection The scanner will automatically detect the status of Caps Lock on the keyboard before data is transmitted; transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Auto Detect Capital Lock ON 82 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 *Capital Lock OFF 83 Update 1560/1562 Series Barcode Scanner User Guide Alphabets Transmission By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabets transmitted according to the status of Caps Lock on the keyboard only. Ignore Case *Case-sensitive Refer to 5.1 Letter Case. 84 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Digits Transmission By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if you wish to use the keys on the numeric keypad. Numeric Key *Alphanumeric Key Note: If you select “Numeric Keypad”, the Num Lock status of the physical keyboard should be “ON”. 85 Update 1560/1562 Series Barcode Scanner User Guide ALT Composing By default, Alternate key composing is disabled. Select [Yes] to allow emulating Alternate key code of a specific keyboard character. For example, [Alt] + [065] will be sent to host for the character “A” regardless the keyboard type you are using. Yes *No Laptop Support By default, laptop support is disabled. It is suggested to enable this feature if you connect the wedge cable to a laptop without an external keyboard being inter-connected. Enable *Disable 86 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 2.4 2.4.3 INTERINTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Character Delay… (*0~254) 1) Read the barcode above to specify the inter-character delay. 2) Read the “Decimal Value” barcode on page 241 for the desired inter-character delay (millisecond). 3) Read the “Validate” barcode on the same page to complete this setting. 2.4 2.4.4 INTERINTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Function Delay… (*0~254) 1) Read the barcode above to specify the inter-function delay. 2) Read the “Decimal Value” barcode on page 241 for the desired inter-function delay (millisecond). 3) Read the “Validate” barcode on the same page to complete this setting. 87 Update 1560/1562 Series Barcode Scanner User Guide 2.5 RSRS-232 VIA 3656 CRADLE Use the RS-232 cable to connect the scanner via 3656 CRADLE to the serial port of PC, and connect the power supply cord. The associated RS-232 parameters must match those configured on the computer. You may run HyperTerminal.exe on your computer, and the scanned data will be transmitted to the computer. RSRS-232 Settings Defaults Baud Rate, Data Bit, Parity, Stop Bit 115200 bps, 8 bits, No parity, 1 stop bit Flow Control None Inter-Character Delay 0 (ms) Inter-Function Delay 0 (ms) ACK/NAK Timeout ACK/NAK Beep Disable 2.5 2.5.1 ACTIVATE RSRS-232 INTERFACE Activate 3656 CRADLE RS-232 Interface 2.5 2.5.2 BAUD RATE *115200 bps 57600 bps 38400 bps 19200 bps 9600 bps 88 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4800 bps 2400 bps 1200 bps 600 bps 2.5 2.5.3 DATA BITS *8 bits 7 bits 2.5 2.5.4 PARITY *No parity Even Odd 89 Update 1560/1562 Series Barcode Scanner User Guide 2.5 2.5.5 STOP BIT 2 stop bits *1 stop bit 2.5 2.5.6 FLOW CONTROL By default, there is no flow control in use. Select the flow control (handshake) method. Options Description No No flow control Scanner Ready The scanner will activate the RTS signal upon powering on. After each good read, the scanner will then wait for the CTS signal to become active. Data will not be sent until the CTS signal becomes active. Data Ready The RTS signal will be activated after each good read. The scanner will then wait for the CTS signal to become active. Data will not be sent until the CTS signal becomes active. Inverted Data Ready It works the same as the Data Ready flow control except that the RTS signal level is inverted. *None Scanner Ready Data Ready Invert Data Ready 90 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 2.5 2.5.7 INTERINTER-CHARACTER DELAY By default, the inter-character delay is zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Character Delay… (*0~254) 1) Read the barcode above to specify the inter-character delay. 2) Read the “Decimal Value” barcode on page 241 for the desired inter-character delay (millisecond). 3) Read the “Validate” barcode on the same page to complete this setting. 2.5 2.5.8 INTERINTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Function Delay… (*0~254) 1) Read this barcode above to specify the inter-function delay. 2) Read the “Decimal Value” barcode on page 241 for the desired inter-function delay (millisecond). 3) Read the “Validate” barcode on the same page to complete this setting. 91 Update 1560/1562 Series Barcode Scanner User Guide 2.5 2.5.9 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all three attempts fail without any notification, data loss will occur. ACK/NAK Time-out after … (*0~99) 1) Read the barcode above to specify the time interval for the scanner to send data and wait for a response from the host. 2) Read the “Decimal Value” barcode on page 241. For example, read “1” and “0” for the scanner to automatically shut down after idleness off 1 second. 3) Read the “Validate” barcode on the same page to complete this setting. ACK/NAK Error Beep Enable Error Beep *Disable Error Beep Note: We suggest enabling the error beep so that you will be notified of such data loss and have the scanner re-read data. 92 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 2.6 2.6 USB HID VIA 3656 CRADLE For USB HID, use the USB cable to connect the scanner via 3656 CRADLE to the USB port of PC and connect the power supply cord. Run any text editor on your computer, and the scanned data will be transmitted to the computer. Warning: When the 3656 CRADLE stand is solely on USB power, the current may be insufficient for it to function normally. You must connect the power supply cord. HID Settings Defaults Keyboard Type PCAT (US) Digits Layout Normal Capital Lock Type Normal Capital Lock State Off Alphabets Transmission Case-sensitive Digits Transmission Alphanumeric keypad Inter-Character Delay 0 (ms) Inter-Function Delay 0 (ms) 93 Update 1560/1562 Series Barcode Scanner User Guide 2.6 2.6.1 ACTIVATE USB HID & SELECT KEYBOARD KEYBOARD TYPE When USB HID interface is activated, you will have to select a keyboard type to complete this setting. Activate 3656 CRADLE USB HID & Select Keyboard Type… 1) Read the barcode above to activate USB HID and select a keyboard type. 2) Read the “Decimal Value” barcode on page 241. Refer to the table below for the number of desired keyboard type. 3) Read the “Validate” barcode on the same page to complete this setting. USB HID By default, the keyboard type is set to PCAT (US). The following keyboard types are supported — No. Keyboard Type No. Keyboard Type 64 PCAT (US) 72 PCAT (Spanish) 65 PCAT (French) 73 PCAT (Portuguese) 66 PCAT (German) 74 PS55 A01-2 (Japanese) 67 PCAT (Italy) 75 User-defined table 68 PCAT (Swedish) 76 PCAT (Turkish) 69 PCAT (Norwegian) 77 PCAT (Hungarian) 70 PCAT (UK) 78 PCAT (Swiss German) 71 PCAT (Belgium) 79 PCAT (Danish) 94 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 2.6 2.6.2 KEYBOARD SETTINGS Alphabets Layout Digits Layout Capital Lock Type Capital Lock Setting Alphabets Transmission Digits Transmission Alphabets Layout By default, the alphabets layout is set to normal mode, also known as the standard English layout. Select French or German keyboard layout if necessary. The scanner will make adjustments when sending the "A", "Q", "W", "Z", "Y", and "M" characters according to this setting. *Normal AZERTY QWERTZ Note: This setting only works when the keyboard type selected is US keyboard, such as PCAT (US). The Alphabets Layout and Digits Layout setting must match your keyboard. 95 Update 1560/1562 Series Barcode Scanner User Guide US Keyboard Style – Normal QWERTY layout, which is normally used in western countries. Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters. French Keyboard Style – AZERTY French layout; see below for French Keyboard Style. Select “Upper Row” for the “Digits Layout” setting for the lower row is for special characters. German Keyboard Layout – QWERTZ German layout; see below for German Keyboard Style. Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters. 96 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Digits Layout Select a proper layout that matches the alphabets layout. The scanner will make adjustments according to this setting. Options Description Normal Depends on the [Shift] key or [Shift Lock] setting Lower Row For QWERTY or QWERTZ keyboard Upper Row For AZERTY keyboard *Normal Upper Row Lower Row Note: This setting is to be used with the Character Substitution setting when support to certain keyboard types (languages) is unavailable but required. 97 Update 1560/1562 Series Barcode Scanner User Guide Capital Lock Type & Setting In order to send the alphabets with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabets being transmitted. Cap Lock Type Description Normal Normal type Capital Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys. Shift Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. In addition, this affects the number or punctuation keys. *Normal Shift Lock Capital Lock Capital Lock State Description Capital Lock OFF Assuming that the status of Caps Lock on the keyboard is OFF, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Capital Lock ON Assuming that the status of Caps Lock on the keyboard is ON, transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Refer to the Capital Lock Type above. Auto Detection The scanner will automatically detect the status of Caps Lock on the keyboard before data is transmitted; transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabets Transmission). Auto Detect Capital Lock ON 98 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 *Capital Lock OFF 99 Update 1560/1562 Series Barcode Scanner User Guide Alphabets Transmission By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabets transmitted according to the status of Caps Lock on the keyboard only. Ignore Case *Case-sensitive Refer to 5.1 Letter Case. 100 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Digits Transmission Transmission By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if you wish to use the keys on the numeric keypad. Numeric Key *Alphanumeric Key Note: If you select “Numeric Keypad”, the Num Lock status of the physical keyboard should be "ON". 2.6.3 INTERINTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Character Delay… (*0~254) 1) Read the barcode above to specify the inter-character delay. 2) Read the “Decimal Value” barcode on page 241 for the desired inter-character delay (millisecond). 3) Read the “Validate” barcode on the same page to complete this setting. 101 Update 1560/1562 Series Barcode Scanner User Guide 2.6 2.6.4 INTERINTER-FUNCTION DELAY DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Function Delay… (*0~254) 1) Read the barcode above to specify the inter-function delay. 2) Read the “Decimal Value” barcode on page 241 for the desired inter-function delay (millisecond). 3) Read the “Validate” barcode on the same page to complete this setting. 2.6 2.6.5 HID CHARACTER TRANSMIT TRANSMIT MODE B By default, HID interface sends data to the host character by character. You may have the scanner read the “Batch Processing” barcode to process data in batch. Batch Processing *By Character 102 Enter Setup Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 2.7 2.7 USB VIRTUAL COM VIA 3656 CRADLE Use the USB cable to connect the scanner via 3656 CRADLE to the USB port of PC and connect the power supply cord. You may run HyperTerminal.exe on your computer, and the scanned data will be transmitted to the computer. Warning: When the 3656 CRADLE stand is solely on USB power, the current may be insufficient for it to function normally. You must connect the power supply cord. Note: If using USB Virtual COM for the first time, you must install its driver beforehand. Driver version 5.4 or later is required. Please remove older versions! 2.7 2.7.1 ACTIVATE USB VIRTUAL COM Activate 3656 CRADLE USB Virtual COM 2.7 2.7.2 INTERINTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Function Delay… (*0~254) 1) Read the barcode above to specify the inter-function delay. 2) Read the “Decimal Value” barcode on page 241 for the desired inter-function delay (millisecond). 3) Read the “Validate” barcode on the same page to complete this setting. 103 Update 1560/1562 Series Barcode Scanner User Guide 2.7 2.7.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all three attempts fail without any notification, data loss will occur. ACK/NAK Time-out after … (*0~99) 1) Read the barcode above to specify the time interval for the scanner to send data and wait for a response from the host. 2) Read the “Decimal Value” barcode on page 241. For example, read “1” and “0” for the scanner to automatically shut down after being idle for 1 second. 3) Read the “Validate” barcode on the same page to complete this setting. ACK/NAK Error Beep Enable Error Beep *Disable Error Beep Note: We suggest enabling the error beep so that you will be notified of such data loss and have the scanner re-read data. 104 Enter Setup Chapter 3 SETTING UP A WPAN CONNECTION The 1560/1562 scanner can be configured to send data to a host computer wirelessly via the 3656 CRADLE stand, or to a notebook computer or PDA with Bluetooth® wireless technology. Upon powering up, the scanner will be ready for establishing a WPAN connection. To establish a connection via 3656 CRADLE after reading “Set Connection” and “Serial No.” labels … Interface Option Reference Keyboard Wedge 2.4 Keyboard Wedge via RS-232 2.5 RS-232 via USB HID 2.6 USB HID via USB Virtual COM 2.7 USB Virtual COM via To establish establish a connection via Bluetooth® dongle after pairing… pairing… Interface Option Reference BT HID 2.1 BT HID BT SPP 2.2 BT SPP Slave, 2.3 BT SPP Master 105 Update 1560/1562 Series Barcode Scanner User Guide IN THIS CHAPTER 3.1 Connecting via ........................................................ 107 3.2 Connecting via Bluetooth® Dongle ............................... 111 106 Enter Setup Chapter 3 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 3.1 3.1 CONNECTING VIA 3656 CRADLE By default, the interface of 3656 CRADLE is set to “USB HID”. Use the interface cable to connect the scanner via 3656 CRADLE to PC. You can have up to seven scanners connected to one computer at the same time. Note: If using USB Virtual COM for the first time, you must install its driver beforehand. Driver version 5.4 or later is required. Please remove older versions! 3.1 3.1.1 CONNECT TO 3656 CRADLE By scanning two setting barcodes in sequence Connect any scanner to 3656 CRADLE by reading the two labels at the back of 3656 CRADLE. The scanner will respond with one beep upon reading each of the labels. “Set Connection” label “Serial Number” label After reading these labels, the scanner will stay active for a specified period of time (2 minutes by default) trying to connect to the 3656 CRADLE while its LED is flashing blue (On/Off ratio 0.5 s: 0.5 s). Once connected, the scanner will respond with three beeps (tone ascending from low to high), and the LED flashes blue (On/Off ratio 0.02 s: 3 s). When out of range, the scanner will respond with three short beeps (tone descending from high to low). Usage: Read the “Set Connection” barcode first, and then the “Serial Number” barcode. If the “Set Connection” barcode on 3656 CRADLE is illegible, try this one — Set Connection Note: The 3656 CRADLE settings will overwrite the interface-related settings on the scanners that are currently connected to 3656 CRADLE. By scanning a single 1D setting barcode Users can produce a single 1D setup barcode that combines the “Set Connection” and “3656 CRADLE Serial Number” setup commands to connect with the target device. While producing the barcode, be aware the letter upper/lower case “SeTcOn” and the barcode must be the Code 128 symbology. Usage: Read the “SeTcOnxxxxxxxxx” single 1D barcode. The scanner will respond with one beep upon reading the barcode. 107 Update 1560/1562 Series Barcode Scanner User Guide 3.1 3.1.2 CHANGE INTERFACE If you want to change the interface cable of 3656 CRADLE, use one of the scanners to configure the interface-related settings and it will pass the new settings to 3656 CRADLE, which will then initialize and pass the settings to any other connected scanners. 1) Have the scanner read the “Set Connection” and “Serial Number” labels at the back of 3656 CRADLE. 2) Within two minutes, connect the interface cable between 3656 CRADLE and your computer. For USB Virtual COM, you may need to install its driver first! 3) The scanners will connect to your computer via 3656 CRADLE. 4) Have one scanner read the “Enter Setup” barcode to enter the configuration mode. 5) Have the scanner read the desired interface barcode and configure its related settings – “Activate Keyboard Wedge & Select Keyboard Type” “Activate RS-232” “Activate USB HID & Select Keyboard Type” “Activate USB Virtual COM” 6) Have the scanner read the “Update” barcode to exit the configuration mode. 7) After the scanner resumes connection with 3656 CRADLE, it will pass the interface-related settings to 3656 CRADLE. 8) Upon receipt of the new settings, 3656 CRADLE will initialize itself. 9) Updated with new settings, 3656 CRADLE will pass the settings to other connected scanners. 108 Enter Setup Chapter 3 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 109 Update 1560/1562 Series Barcode Scanner User Guide 3.1.3 3.1.3 CONFIGURE CONFIGURE RELATED SETTINGS Sniff Mode (Power(Power-saving) By default, this feature is enabled, meaning the scanner will listen to the wireless network at a reduced rate. *Enable Disable 110 Enter Setup Chapter 3 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 3.2 3.2 CONNECTING VIA BLUETOOTH® DONGLE 3.2 3.2.1 CHANGE CHANGE INTERFACE Below is the procedure to configure the scanner before establishing a WPAN connection via Bluetooth® dongle. 1) Have the scanner read the “Enter Setup” barcode to enter the configuration mode. 2) Have the scanner read the desired interface barcode – “Activate BT HID & Select Keyboard Type” “Activate BT SPP Slave Mode” “Activate BT SPP Master Mode” 3) Have the scanner read the barcodes related to WPAN settings, such as Device Name Broadcasting, Authentication & PIN Code, etc. 4) Have the scanner read the “Update” barcode to exit the configuration mode. 5) The scanner will stay active for a specified period of time (2 minutes by default) waiting for a connection request from the host (SPP Slave Mode) or trying to connect to the host (HID or SPP Master Mode). Its CPU is running at full speed, and the LED is flashing blue (On/Off ratio 0.5 s: 0.5 s). Once connected, when getting out of range, the scanner will respond with three short beeps (tone descending from high to low). 111 Update 1560/1562 Series Barcode Scanner User Guide 3.2.2 CONFIGURE CONFIGURE RELATED SETTINGS Sniff Mode (Power(Power-saving) By default, this feature is enabled, meaning the scanner will listen to the wireless network at a reduced rate. *Enable Disable Note: When connecting more than two scanners to a notebook computer or PDA with Bluetooth® wireless technology, we suggest that you disable the power-saving setting for a more reliable connection. Device Name Broadcasting The scanner can be configured to hide itself from other devices equipped with Bluetooth® wireless technology. Simply disable the device name broadcasting setting so that it won’t be discovered by any other computer or PDA. However, broadcasting must be enabled for establishing an initial connection with the scanner. For example, you can disable device name broadcasting after successfully connecting the scanner to WorkStation1. Such connection will be maintained automatically unless the scanner is removed from the paired device list (called unpairing) by WorkStation1 or any changes made to authentication and the PIN code. If you want WorkStation2 to connect to the scanner, you will have to enable device name broadcasting first. *Enable Disable Note: By default, device name broadcasting is enabled (which is required for initial connection). 112 Enter Setup Chapter 3 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Authentication When any changes are made to authentication and PIN code on the scanner side, you will have to remove the scanner from the paired device list (called unpairing) and go through the whole process to re-establish the connection. The scanner allows up to 16 characters for a PIN code and provides two options for authentication: Enable Authentication with Preset PIN Have the scanner read the “Use preset PIN” barcode, and change the preset PIN if necessary. This means you will have to enter exactly the same string for your computer or PDA to connect to the scanner. If the PIN or passkey is incorrect, any connection attempt will be turned down by the scanner. See step 8 in 3.2.3 Connect to Dongle. 1. Read the “Use preset PIN” barcode to enable authentication with a preset PIN. Use Preset PIN 2. Read one of the barcodes to specify the PIN code, in decimal or hexadecimal. By default, the PIN code is set to “0000”. Maximum 16 characters are allowed. Enter PIN in Hexadecimal … Enter PIN in Decimal… 3. Read the “Decimal Value” barcode on page 241 or the “Hexadecimal Value” barcode on page 242 for the desired digits or character string. Read the “Clear PIN Code” barcode first if you need to re-input the PIN code. Clear PIN Code 4. Read the “Validate” barcode to complete this setting. Enable Authentication with Random PIN or No Authentication By default, it is set to “No PIN or use random PIN”, which depends on the setting of the target device. (No PIN = No authentication.) *No PIN or use random PIN 113 Update 1560/1562 Series Barcode Scanner User Guide Use random PIN No PIN required Note: When using BT HID, some device driver may not support pre-defined PIN code for authentication. In this case, make sure you have the scanner set to “No PIN or use random PIN” before pairing. While pairing, the host PIN code will be displayed on the computer screen. Have the scanner read the setup barcode “Enter PIN Code in Decimal” or “Enter PIN Code in Hexadecimal” to input the matching PIN code. Refer to Disable Authentication or Use Random PIN. 114 Enter Setup Chapter 3 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 3.2.3 3.2.3 CONNECT TO DONGLE The procedure goes through associating devices for establishing a WPAN connection, which is pretty much the same except for the software you are using. If your computer is running Microsoft® Windows® XP Service Pack 3 (SP3) or Windows Vista® Service Pack 1 (SP1), you can use the software support that Windows® includes, or you can use the driver that the device manufacturer provides. Now, let’s try using the software support that Windows® XP Service Pack 2 includes. BT HID Procedure By default, BT HID is activated on the scanner, and the keyboard type is set to PCAT (US). When BT HID is re-activated, you will have to select a keyboard type to complete this setting. The procedure is the same as for BT SPP. Refer to steps 1~11 below. BT SPP Procedure 1. Turn on the Bluetooth® function on your computer, running Windows XP SP2. 2. Double-click the Bluetooth® icon from the lower right of the taskbar. Alternatively, you may go to Control Panel > Bluetooth Devices. 3. Click [Add] to search devices nearby. 115 Update 1560/1562 Series Barcode Scanner User Guide 4. Turn on the scanner with correct WPAN settings, such as select BT SPP or BT HID, broadcasting enabled, authentication enabled, and PIN code specified, etc. Select the check box of [My device is set up and ready to be found] on your computer. 5. Click [Next]. 6. Wait for a few seconds for the Wizard to search available devices nearby. The scanner will appear with its “serial number” as the device name. You may double-check the “Serial Number” label on the scanner to ensure connecting with the correct scanner. Select the target scanner. If the target scanner does not appear on the list, click [Search Again] to refresh the list. The scanner might enter Suspend Mode now, and you can press the trigger to have it active again (=discoverable). It will then stay active for a specified period of time (2 minutes by default) and wait for PC to establish a connection. 116 Enter Setup Chapter 3 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字 套用到您想要在此處顯示的文字。 您想要在此處顯示的文字。 7. Click [Next]. 8. Enter the passkey for authentication, which must be exactly the same as configured for the scanner. 117 Update 1560/1562 Series Barcode Scanner User Guide 9. Click [Next]. Wait for a few seconds for Windows to exchange passkeys. 118 Enter Setup Chapter 3 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Note: When Bluetooth security is enabled without providing a pre-set PIN code, dynamic input of PIN code is supported. 10. Click [Finish]. 1560 as BT SPP Slave 1560 as BT SPP Master 119 Update 1560/1562 Series Barcode Scanner User Guide 11. Now the target scanner will be listed as shown below. You can have up to seven scanners connected to one computer at the same time. Select and Remove Note: When any changes are made to authentication and PIN code on the scanner side, or you want to change to use BT HID, it is suggested that you remove the scanner from the paired device list (called unpairing) and go through the whole process to re-establish the connection. 12. Run the desired application on your computer, such as HyperTerminal.exe if using BT SPP or Notepad.exe if using BT HID. The status of the scanner listed on the device list will be updated to “Connected”, indicating the WPAN connection is established successfully via the outgoing COM port if using BT SPP. Note: Even though the scanner is connected to the host with authentication disabled (= no PIN code required), the host may still request a PIN code while the application is opening COM port. Dynamic input of PIN code is supported so that you may input a matching PIN code on the scanner. Refer to Disable Authentication or Use Random PIN. 120 Enter Setup Chapter 3 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 BT SPP Connected BT SPP Disconnected 121 Update 1560/1562 Series Barcode Scanner User Guide 3.2.4 SECURE SIMPLE PAIRING (SSP) Secure Simple Pairing (SSP), introduced in Bluetooth® Core Specification 2.1 + EDR, is a new feature designed to ease the pairing process while keeping up the communication security level. When connecting to a Bluetooth® host that supports Bluetooth® HID or Bluetooth® SPP profile, you can implement the secure simple pairing process. This function is enabled by default; the password dialog box won’t show up during the pairing process. Disable *Enable Note: Secure Simple Pairing only supports to devices with Bluetooth® v2.1 or later. 122 Enter Setup Chapter 4 CHANGING SYMBOLOGY SETTINGS In this chapter, a brief on the symbology settings is provided for your reference. IN THIS CHAPTER 4.1 Codabar ................................................................... 4.2 Code 25 – Industrial 25 ............................................. 4.3 Code 25 – Interleaved 25........................................... 4.4 Code 25 – Matrix 25 .................................................. 4.5 Code 39 ................................................................... 4.6 Trioptic Code 39 ....................................................... 4.7 Code 93 ................................................................... 4.8 Code 128 ................................................................. 4.9 EAN-8...................................................................... 4.10 EAN-13 .................................................................. 4.11 GS1-128 (EAN-128) ................................................ 4.12 ISBT 128................................................................ 4.13 MSI ....................................................................... 4.14 French Pharmacode ................................................. 4.15 Italian Pharmacode ................................................. 4.16 Plessey .................................................................. 4.17 GS1 DataBar (RSS Family) ....................................... 4.18 Telepen .................................................................. 4.19 UPC-A .................................................................... 4.20 UPC-E .................................................................... 4.21 Code 11 ................................................................. 124 126 129 132 135 137 137 137 138 141 144 145 147 149 150 151 152 157 160 162 165 123 Update 1560/1562 Series Barcode Scanner User Guide 4.1 CODABAR *Enable Disable 4.1.1 START/STOP CHARACTERS CHARACTERS SELECTION Select one of the four different start/stop character pairs – * abcd/abcd abcd/tn*e ABCD/ABCD ABCD/TN*E 124 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.1.2 START/STOP TRANSMISSION TRANSMISSION Decide whether to include the start/stop characters in the data being transmitted. Transmit Start/Stop Characters *Do Not Transmit 4.1.3 CLSI CONVERSION CONVERSION When enabled, the CLSI editing strips the start/stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar barcode. Apply CLSI Editing *Do Not Apply Note: The 14-character barcode length does not include start/stop characters. 4.1.4 SECURITY SECURITY LEVEL Security Level renders more decoding accuracy giving consideration to barcodes’ print quality. Decide the security level for reading CodaBar barcodes. Normal *High 125 Update 1560/1562 Series Barcode Scanner User Guide 4.2 CODE 25 – INDUSTRIAL 25 *Enable Disable 4.2.1 START/STOP START/STOP PATTERN SELECTION SELECTION This decides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 2 of 5 barcode but with Interleaved 2 of 5 start/stop pattern. In order to read this barcode, the start/stop pattern selection parameter of Industrial 2 of 5 should set to "Interleaved 25". *Industrial 25 Start/Stop Pattern Interleaved 25 Start/Stop Pattern Matrix 25 Start/Stop Pattern 4.2.2 VERIFY CHECK DIGIT Decide whether to verify the check digit. If incorrect, the barcode will not be accepted. Verify Industrial 25 Check Digit *Do Not Verify 126 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.2.3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. *Transmit Industrial 25 Check Digit Do Not Transmit 4.2.4 CODE LENGTH QUALIFICATION QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If “Fixed Length” is selected, up to 2 fixed lengths can be specified. 1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification. *Enable Max./Min. Length (0~127)… Enable Fixed Length(s)… 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2. 127 Update 1560/1562 Series Barcode Scanner User Guide Max. Length (*127) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 3) Read the “Decimal Value” barcode on page 241 for the desired length. 4) Read the “Validate” barcode on the same page to complete this setting. 4.2.5 SECURITY LEVEL (1560P ONLY) Security Level renders more decoding accuracy giving consideration to barcodes’ print quality. Decide the security level for reading Code 25 barcodes. Normal *High 128 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.3 CODE 25 – INTERLEAVED 25 *Enable Disable 4.3.1 START/STOP PATTERN PATTERN SELECTION This decides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 2 of 5 barcode but with Interleaved 2 of 5 start/stop pattern. In order to read this barcode, the start/stop pattern selection parameter of Industrial 2 of 5 should set to "Interleaved 25". Industrial 25 Start/Stop Pattern *Interleaved 25 Start/Stop Pattern Matrix 25 Start/Stop Pattern 129 Update 1560/1562 Series Barcode Scanner User Guide 4.3.2 VERIFY CHECK DIGIT Decide whether to verify the check digit. If incorrect, the barcode will not be accepted. Verify Interleaved 25 Check Digit *Do Not Verify 4.3.3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. *Transmit Interleaved 25 Check Digit Do Not Transmit 130 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.3.4 CODE LENGTH QUALIFICATION QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If “Fixed Length” is selected, up to 2 fixed lengths can be specified. 1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification. *Enable Max./Min. Length (0~127)… Enable Fixed Length(s)… 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2. Max. Length (*126) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 3) Read the “Decimal Value” barcode on page 241 for the desired length. 4) Read the “Validate” barcode on the same page to complete this setting. 4.3.5 SESURITY LEVEL (1560P ONLY) Security Level renders more decoding accuracy giving consideration to barcodes’ print quality. Decide the security level for reading Code 25 barcodes. Please refer to 4.2.5 Security Level. 131 Update 1560/1562 Series Barcode Scanner User Guide 4.4 CODE 25 – MATRIX 25 Enable *Disable 4.4.1 START/STOP PATTERN PATTERN SELECTION This decides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 2 of 5 barcode but with Interleaved 2 of 5 start/stop pattern. In order to read this barcode, the start/stop pattern selection parameter of Industrial 2 of 5 should set to "Interleaved 25". Industrial 25 Start/Stop Pattern Interleaved 25 Start/Stop Pattern *Matrix 25 Start/Stop Pattern 132 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.4.2 VERIFY CHECK DIGIT Decide whether to verify the check digit. If incorrect, the barcode will not be accepted. Verify Matrix 25 Check Digit *Do Not Verify 4.4.3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. *Transmit Matrix 25 Check Digit Do Not Transmit 133 Update 1560/1562 Series Barcode Scanner User Guide 4.4.4 CODE LENGTH QUALIFICATION QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If “Fixed Length” is selected, up to 2 fixed lengths can be specified. 1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification. *Enable Max./Min. Length (0~127)… Enable Fixed Length(s)… 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2. Max. Length (*127) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 3) Read the “Decimal Value” barcode on page 241 for the desired length. 4) Read the “Validate” barcode on the same page to complete this setting. 4.4.5 SECURITY LEVEL (1560P ONLY) Security Level renders more decoding accuracy giving consideration to barcodes’ print quality. Decide the security level for reading Code 25 barcodes. Please refer to 4.2.5 Security Level. 134 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.5 4.5 CODE 39 *Enable Disable 4.5.1 START/S START/STOP /STOP TRANSMISSION Decide whether to include the start/stop characters in the data being transmitted. Transmit Code 39 Start/Stop Characters *Do Not Transmit 4.5.2 VERIFY CHECK DIGIT Decide whether to verify check digit. If incorrect, the barcode will not be accepted. Verify Code 39 Check Digit *Do Not Verify 135 Update 1560/1562 Series Barcode Scanner User Guide 4.5.3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. *Transmit Code 39 Check Digit Do Not Transmit 4.5.4 STANDARD/FULL ASCII CODE 39 Decide whether to support Code 39 Full ASCII that includes all the alphanumeric and special characters. Code 39 Full ASCII *Standard Code 39 4.5.5 SECURITY LEVEL Security Level renders more decoding accuracy giving consideration to barcodes’ print quality. Decide the security level for reading Code 39 barcodes. *Normal High 136 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.5.6 ASTERISKS ASTERISKS (*) AS DATA CHARACTERS Decide whether to take asterisk (*) as part of the data. Enable *Disable 4.6 TRIOPTIC CODE 39 Enable *Disable 4.7 4.7 CODE 93 *Enable Disable 4.8 4.8 CODE 128 *Enable Disable 137 Update 1560/1562 Series Barcode Scanner User Guide 4.8 4.8.1 SECURITY LEVEL Security Level renders more decoding accuracy giving consideration to barcodes’ print quality. Decide the security level for reading Code 128 barcodes. *Normal High 4.9 4.9 EANEAN-8 EANEAN-8 *Enable EAN-8 (No Addon) Disable EANEAN-8 Addon 2 Enable EAN-8 Addon 2 *Disable EANEAN-8 Addon Addon 5 Enable EAN-8 Addon 5 *Disable 138 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字 套用到您想要在此處顯示的文字。 您想要在此處顯示的文字。 4.9 4.9.1 CONVERT TO EANEAN-13 Decide whether to expand the read EAN-8 barcode, as well as its addons, into EAN-13. After conversion, the data follows EAN-13 format and is affected by EAN-13 programming selections (e.g. Check Digit). Convert EAN-8 to EAN-13 *Do Not Convert 4.9 4.9.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. *Transmit EAN-8 Check Digit Do Not Transmit 4.9 4.9.3 CONVERSION FORMAT FORMAT When converting EAN-8 to EAN-13, you can scan the barcode below to decide conversion in default or GTIN-13 format. 139 Update 1560/1562 Series Barcode Scanner User Guide *Default Format GTIN-13 Format 140 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.10 4.10 EANEAN-13 EANEAN-13 *Enable EAN-13 (No Addon) Disable EANEAN-13 Addon 2 Enable EAN-13 Addon 2 *Disable EANEAN-13 Addon 5 Enable EAN-13 Addon 5 *Disable 141 Update 1560/1562 Series Barcode Scanner User Guide 4.10 4.10.1 10.1 ISBN CONVERSION Decide whether to convert the EAN-13 barcode, starting with 978 and 979, to ISBN. Convert EAN-13 to ISBN *Do Not Convert 4.10 4.10.2 10.2 ISSN CONVERSION Decide whether to convert the EAN-13 barcode, starting with 977 to ISSN. Convert EAN-13 to ISSN *Do Not Convert 4.10 4.10.3 10.3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. *Transmit EAN-13 Check Digit Do Not Transmit 142 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.10. 4.10.4 SECURITY LEVEL Security Level renders more decoding accuracy giving consideration to barcodes’ print quality. Decide the security level for reading EAN-13 barcodes. *Normal High 143 Update 1560/1562 Series Barcode Scanner User Guide 4.1 4.11 GS1GS1-128 (EAN (EANEAN-128) 128) *Enable Disable Note: When this setting is disabled, GS1-128 barcodes used to be taken as Code 128. However, starting from firmware version 1.01, GS1-128 barcodes can be decoded only when this setting is enabled. 4.1 4.11.1 CODE ID TRANSMISSION TRANSMISSION Decide whether to include the Code ID ("]C1") in the data being transmitted. Transmit Code ID *Do Not Transmit 4.1 4.11.2 FIELD SEPARATOR (GS (GS CHARACTER) Decide whether to apply a field separator (to convert the FNC1 control character to human readable character). Enable Field Separator… 1) Read the barcode above to enable field separator. 2) Read the “Hexadecimal Value” barcode on page 242 for the desired character string. 3) Read the “Validate” barcode to complete this setting. Note: GS1-128 barcodes start with the FNC1 control character to distinguish themselves from other uses of Code 128. FNC1 is also used to separate data fields in the GS1-128 barcodes. 144 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.11 4.11.3 GS1 FORMATTING Decide whether to enable GS1 formatting for GS1-128. Enable *Disable 4.11 4.11.4 APPLICATION ID MARK Decide whether to add an application ID mark (1 character) to the left (AIMark1) or right (AIMark2) of an application ID (AI) for the purpose of labeling it when formatting the GS1 data. AIMark1 AIMark2 1) Read the barcode above to add a mark to the left (AIMark1)/right (AIMark2) of an application ID. 2) Read the “Hexadecimal Value” barcode on page 242 for the desired character string. Read ‘00’ if you want to remove the AI mark. 3) Read the “Validate” barcode to complete this setting. 145 Update 1560/1562 Series Barcode Scanner User Guide 4.12 4.12 ISBT 128 *Enable Disable 4.12 .12.1 ISBT CONCATENATION CONCATENATION Decide whether to decode and concatenate pairs of ISBT barcodes. Auto-discriminate ISBT Concatenation It decodes and concatenates pairs of ISBT barcodes immediately. If only a single ISBT barcode is present, the scanner must decode 10 times before transmitting its data to confirm that there is no additional ISBT barcode. Enable ISBT Concatenation There must be two ISBT barcodes in order for the scanner to decode and perform concatenation. It does not decode single ISBT barcodes. Disable ISBT Concatenation It will not concatenate pairs of ISBT barcodes it encounters. *Auto-discriminate Enable Disable 146 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.1 4.13 MSI Enable *Disable 4.1 4.13.1 VERIFY CHECK DIGIT Select one of the three calculations to verify check digit when decoding barcodes. If incorrect, the barcode will not be accepted. *Single Modulo 10 Double Modulo 10 Modulo 10 & 11 4.13 4.13.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. *Last Digit Not Transmitted Both Digits Transmitted Both Digits Not Transmitted 147 Update 1560/1562 Series Barcode Scanner User Guide 4.1 4.13.3 CODE LENGTH QUALIFICATION QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If “Fixed Length” is selected, up to 2 fixed lengths can be specified. 1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification. *Enable Max./Min. Length (0~127)… Enable Fixed Length(s)… 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2. Max. Length (*127) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 3) Read the “Decimal Value” barcode on page 241 for the desired length. 4) Read the “Validate” barcode on the same page to complete this setting. 148 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.14 4.14 FRENCH PHARMACODE Enable *Disable 4.14 4.14.1 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. *Transmit French Pharmacode Check Digit Do Not Transmit 149 Update 1560/1562 Series Barcode Scanner User Guide 4.15 4.15 ITALIAN PHARMACODE Enable *Disable 4.15 4.15.1 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. *Transmit Italian Pharmacode Check Digit Do Not Transmit 150 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.16 4.16 PLESSEY Enable *Disable 4.16 4.16.1 CONVERT TO UK PLESSEY PLESSEY Decide whether to change each occurrence of the character 'A' to character 'X' in the decoded data. Convert to UK Plessey *Do Not Convert 4.16 4.16.2 TRANSMIT CHECK DIGIT Decide whether to include the two check digits in the data being transmitted. *Transmit Plessey Check Digits Do Not Transmit 151 Update 1560/1562 Series Barcode Scanner User Guide 4.17 4.17 GS1 DATA DATAB TABAR (RSS (RSS FAMILY) FAMILY) It is categorized into three groups: Group I — GS1 DataBar Omnidirectional (RSS(RSS-14) This group consists of the following: GS1 DataBar Omnidirectional GS1 DataBar Truncated GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional Group Group II — GS1 DataBar Expanded (RSS Expanded) This group consists of the following: GS1 DataBar Expanded GS1 DataBar Expanded Stacked Group III — GS1 DataBar Limited (RSS Limited) This group consists of the following: GS1 DataBar Limited 4.17 4.17.1 CODE ID ID SELECTION Select a desired Code ID to use: “]e0“ (GS1 DataBar Code ID) “]C1” (GS1-128 Code ID) Use “]C1” *Use “]e0” 152 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.17 4.17.2 GS1 DATAB DATABAR OMNIDIRECTIONAL (RSS (RSSRSS-14) Enable RSS-14 & RSS Expanded (Groups I, II) *Disable The settings below apply to Group I symbologies only: GS1 DataBar Omnidirectional GS1 DataBar Truncated GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional Transmit Code ID Decide whether to include the Code ID in the data being transmitted. *Transmit RSS-14 Code ID Do Not Transmit Transmit Application ID Decide whether to include the Application ID ("01") in the data being transmitted. *Transmit RSS-14 Application ID Do Not Transmit 153 Update 1560/1562 Series Barcode Scanner User Guide Transmit Check Digit Decide whether to include the check digit in the data being transmitted. *Transmit RSS-14 Check Digit Do Not Transmit 154 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.17 4.17.3 GS1 DATAB DATABAR EXPANDED (RSS (RSS EXPANDED) EXPANDED) Enable RSS-14 & RSS Expanded (Groups I, II) *Disable The settings below apply to Group II symbologies only: GS1 DataBar Expanded GS1 DataBar Expanded Stacked Transmit Code ID Decide whether to include the Code ID in the data being transmitted. *Transmit RSS Expanded Code ID Do Not Transmit 155 Update 1560/1562 Series Barcode Scanner User Guide 4.17 .17.4 GS1 DATAB DATABAR LIMITED (RSS (RSS LIMITED) LIMITED) Enable RSS Limited (Group III) *Disable Transmit Code ID Decide whether to include the Code ID in the data being transmitted. *Transmit RSS Limited Code ID Do Not Transmit Transmit Application Application ID Decide whether to include the Application ID ("01") in the data being transmitted. *Transmit RSS Limited Application ID Do Not Transmit Transmit Check Digit Decide whether to include the check digit in the data being transmitted. *Transmit RSS Limited Check Digit Do Not Transmit 156 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.17 4.17.5 FIELD SEPARATOR (GS CHARACTER) Decide whether to apply a field separator (to convert the GS control character to human readable character). Enable Field Separator… 1) Read the barcode above to enable field separator. 2) Read the “Hexadecimal Value” barcode on page 242 for the desired character string. 3) Read the “Validate” barcode to complete this setting. 4.17. 4.17.6 7.6 GS1 FORMATTING Decide whether to enable GS1 formatting for GS1 DataBar (RSS family). Enable *Disable 4.17 4.17.7 APPLICATION ID MARK Decide whether to add an application ID mark (1 character) to the left (AIMark1) or right (AIMark2) of an application ID (AI) for the purpose of labeling it when formatting the GS1 data. AIMark1 AIMark2 1) Read the barcode above to add a mark to the left (AIMark1)/right (AIMark2) of an application ID. 2) Read the “Hexadecimal Value” barcode on page 242 for the desired character string. Read '00' if you want to remove the AI mark. 3) Read the “Validate” barcode to complete this setting. 157 Update 1560/1562 Series Barcode Scanner User Guide 4.17 4.17.8 SECURITY LEVEL Security Level renders more decoding accuracy giving consideration to barcodes’ print quality. Decide the security level for reading GS1 DataBar barcodes. *Normal High 158 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.18 4.18 TELEPEN Enable Telepen *Disable 4.18 4.18.1 TELEPEN OUTPUT – FULL ASCII/NUMERIC ASCII/NUMERIC Decide whether to support Telepen in full ASCII code. By default, it supports ASCII mode. AIM Telepen (Full ASCII) includes all the alphanumeric and special characters. Original Telepen (Numeric) *AIM Telepen 159 Update 1560/1562 Series Barcode Scanner User Guide 4.19 4.19 UPCUPC-A UPCUPC-A *Enable UPC-A (No Addon) Disable UPCUPC-A Addon 2 Enable UPC-A Addon 2 *Disable UPCUPC-A Addon 5 Enable UPC-A Addon 5 *Disable 160 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.19 4.19.1 CONVERT TO EANEAN-13 Decide whether to expand the read UPC-A barcode, as well as its addons, into EAN-13. After conversion, the data follows EAN-13 format and is affected by EAN-13 programming selections (e.g. Check Digit). Convert UPC-A to EAN-13 *Do Not Convert 4.19 4.19.2 SYSTEM NUMBER TRANSMISSION TRANSMISSION Decide whether to include the system number in the data being transmitted. *Transmit UPC-A System Number Do Not Transmit 4.19 4.19.3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. *Transmit UPC-A Check Digit Do Not Transmit 161 Update 1560/1562 Series Barcode Scanner User Guide 4.20 4.20 UPCUPC-E UPCUPC-E *Enable UPC-E (No Addon) Disable UPCUPC-E Addon 2 Enable UPC-E Addon 2 *Disable UPCUPC-E Addon 5 Enable UPC-E Addon 5 *Disable 162 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.20 4.20.1 20.1 SYSTEM NUMBER SELECTION SELECTION Decide whether to decode the ordinary UPC-E barcodes only or both UPC-E0 and UPC-E1 barcodes. System number 0 enabled for decoding UPC-E0 barcodes. System number 1 enabled for decoding UPC-E1 barcodes. System Number 0 & 1 *System Number 0 Only Warning: Because of the way system number 1 is encoded, if both system numbers are enabled, the user might suffer from short scanning UPC-A or EAN-13 barcodes into UPC-E1 barcodes. 4.20 4.20.2 20.2 CONVERT TO UPCUPC-A Decide whether to expand the read UPC-E barcode, as well as its addons, into UPC-A. After conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g. System Number, Check Digit). Convert UPC-E to UPC-A *Do Not Convert 163 Update 1560/1562 Series Barcode Scanner User Guide 4.20 4.20.3 20.3 SYSTEM NUMBER TRANSMISSION TRANSMISSION Decide whether to include the system number in the data being transmitted. Transmit UPC-E System Number *Do Not Transmit 4.20 4.20.4 20.4 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. *Transmit UPC-E Check Digit Do Not Transmit 164 Enter Setup Chapter 4 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 4.21 CODE 11 Enable *Disable 4.21.1 4.21.1 VERIFY VERIFY CHECK DIGIT Select one of the verification when decoding barcodes. If incorrect, the barcode will not be accepted. None Double Single *Auto 165 Update 1560/1562 Series Barcode Scanner User Guide 4.21. 4.21.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. *Transmit Check Digit Do Not Transmit 4.21.3 4.21.3 SECURITY LEVEL Security Level renders more decoding accuracy giving consideration to barcodes’ print quality. Decide the security level for reading Code 11 barcodes. Normal *High 166 Enter Setup Chapter 5 DEFINING OUTPUT OUTPUT FORMAT You may configure in which format the collected data will be output to the host computer. Barcode read by the scanner will be processed in the following sequence – 1) Perform character substitution on the data scanned. 2) Add Code ID and Length Code to the front of the data:[Code ID][Length Code][Data] 3) Process the whole data in step 2 with user formats. Data is now divided into fields by user specified rules. Refer to Chapter 6 Applying Formats for Data Editing. 4) Add Prefix Code and Suffix Code before transmission:[Prefix Code][Processed Data][Suffix Code] IN THIS CHAPTER 5.1 5.2 5.3 5.4 5.5 5.6 5.7 Letter Case .............................................................. Character Substitution ............................................... Prefix/Suffix Code ..................................................... Code ID ................................................................... Length Code ............................................................. Multi-Barcode Editor .................................................. Removal of Special Character ..................................... 167 168 176 177 182 186 190 5.1 LETTER CASE By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case. Ignoring the original letter case, select [Upper Case] to output data in upper case only; otherwise, select [Lower Case] to output data in lower case only. *Normal Upper Case Lower Case 167 Update 1560/1562 Series Barcode Scanner User Guide 5.2 CHARACTER SUBSTITUTION SUBSTITUTION Character substitution is performed on every occurrence of the first character specified. If only one character is specified, every occurrence of that character in the barcode will be taken away. The first character will be replaced by the second character(s). Up to three sets of character substitution can be configured. If “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type. Key Type Key Status Scan Code Only 1 scan code value is allowed. Refer to 5.2.1 Select a Set for Character Substitution. Normal Key Up to 3 allowed. character strings are N/A Add Shift Add Left Ctrl Add Left Alt Add Right Ctrl Add Right Alt Refer to Keyboard Wedge Table. Note: The character substitution is performed only on the barcode itself and before the processing of editing formats. It is not applicable to the Prefix/Suffix Code, Code ID, Length Code, or any Additional Field. 168 Enter Setup Chapter 5 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 5.2.1 SELECT A SET FOR FOR CHARACTER SUBSTITU SUBSTITUT UBSTITUTION Configure Set 1 Configure Set 2 Configure Set 3 1) Read the barcode above to enable character substitution by set. For example, have the scanner read the “Set 1” barcode to configure the first set of character substitution. The scanner will respond with one short beep, high tone, to indicate more setup barcodes are required. 2) Read the “Hexadecimal Value” barcode on page 242 for the desired character substitution. For example, KEY TYPE = NORMAL Read “3”, “0”, “2”, and “D” to replace the character “0” with a dash “-”. Read “3”, “0”, “2”, “D”, “3”, and “0” to replace the character “0” with a dash “-0”. KEY TYPE = SCAN CODE If you want to replace the character “0” with “a” (= “1C” on the scan code table): 1. Read “3” and “0”. 2. Read the “Scan Code” barcode. 3. Read “1” and “C”. KEY TYPE = NORMAL + KEY STATUS = SHIFT If you want to replace the character “0” with “!” (= “Shift” + “1” on keyboard): 1. Read “3” and “0”. 2. Read the “Add Shift” barcode. 3. Read “3” and “1”. 3) Read the “Validate” barcode to complete this setting. (The defined set or sets will be applied to all symbologies by default.) 169 Update 1560/1562 Series Barcode Scanner User Guide 5.2.2 SYMBOLOGIES FOR FOR CHARACTER SUBSTITUTION SUBSTITUTION (ALL 3 SETS) By default character substitution will be performed on all symbologies. If the character substitution is not desired with one or more symbologies, read the “Do Not Apply” barcode for each undesired symbologies and all the three sets will be ignored for them. Character Substitution for Codabar *Apply Do Not Apply Character Substitution for Code 39 *Apply Do Not Apply Character Substitution for Trioptic Code 39 *Apply Do Not Apply Character Substitution for Code 93 *Apply Do Not Apply Character Substitution for Code 128 170 Enter Setup Chapter 5 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 *Apply Do Not Apply Character Substitution for GS1GS1-128 *Apply Do Not Apply Character Substitution for ISBT 128 *Apply Do Not Apply Character Substitution for for EANEAN-8 (No Addon) *Apply Do Not Apply Character Substitution for EANEAN-8 Addon 2 *Apply Do Not Apply Character Substitution for EANEAN-8 Addon 5 171 Update 1560/1562 Series Barcode Scanner User Guide *Apply Do Not Apply Character Substitution for EANEAN-13 (No Addon) Addon) *Apply Do Not Apply Character Substitution for EANEAN-13 Addon 2 *Apply Do Not Apply Character Substitution for EANEAN-13 Addon 5 *Apply Do Not Apply Character Substitution for French Pharmacode *Apply Do Not Apply Character Character Substitution for Italian Pharmacode 172 Enter Setup Chapter 5 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 *Apply Do Not Apply Character Substitution for Industrial 25 *Apply Do Not Apply Character Substitution for Interleaved 25 *Apply Do Not Apply Character Substitution for Matrix 25 *Apply Do Not Apply Character Substitution for MSI *Apply Do Not Apply Character Substitution for Plessey 173 Update 1560/1562 Series Barcode Scanner User Guide *Apply Do Not Apply Character Substitution for GS1 DataBar *Apply Do Not Apply Character Substitution Substitution for Telepen *Apply Do Not Apply Character Substitution for UPCUPC-A (No Addon) Addon) *Apply Do Not Apply Character Substitution for UPCUPC-A Addon 2 *Apply Do Not Apply Character Substitution for UPCUPC-A Addon 5 174 Enter Setup Chapter 5 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 *Apply Do Not Apply Character Substitution for UPCUPC-E (No Addon) Addon) *Apply Do Not Apply Character Substitution for UPCUPC-E Addon 2 *Apply Do Not Apply Character Substitution for UPCUPC-E Addon 5 *Apply Do Not Apply Character Substitution for Code 11 *Apply Do Not Apply 175 Update 1560/1562 Series Barcode Scanner User Guide 5.3 PREFIX/SUFFIX CODE CODE By default, there is no prefix code, and [ENTER] or [CR] (Carriage Return) is configured to be suffix code. Up to 8 characters can be configured, for example, “Barcode_”, and you will have the string appear in front of the barcode read, like this – “Barcode_1234567890”. If “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type. Key Type Key Status Scan Code Up to 4 allowed. Normal Key Up to 8 allowed. scan code character values are strings are N/A Add Shift Add Left Ctrl Add Left Alt Add Right Ctrl Add Right Alt Refer to Keyboard Wedge Table. Configure Prefix Configure Suffix 1) Read the barcode above to apply prefix code or suffix code separately, and follow steps 2~3. (Max. 8 characters each) 2) Read the “Hexadecimal Value” barcode on page 242 for the desired character string. For example, read “2” and “B” for the scanner to prefix or suffix the character [+]. 3) Read the “Validate” barcode to complete this setting. 176 Enter Setup Chapter 5 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 5.4 CODE ID Up to two characters for Code ID can be configured for each symbology. To make the Code ID configuration easier, the scanner provides five pre-defined Code ID sets that you can select one and make necessary changes on it. If “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type. Key Type Key Status Scan Code Only 1 scan code value is allowed. Normal Key Up to 2 allowed. character strings N/A are Add Shift Add Left Ctrl Add Left Alt Add Right Ctrl Add Right Alt Refer to Keyboard Wedge Table. Note: "]C1" is the Code ID of GS1-128 (EAN-128) barcodes; "]e0" is the default Code ID of GS1 DataBar (RSS) barcodes. 5.4.1 5.4.1 SELECT PREPRE-DEFINED CODE ID Apply Code ID Set 1 Apply Code ID Set 2 Apply Code ID Set 3 Apply Code ID Set 4 Apply Code ID Set 5 177 Update 1560/1562 Series Barcode Scanner User Guide Code ID options Set 1 Set 2 Set 3 Set 4 Set 5 Code 39 Trioptic Code 39 Italian Pharmacode French Pharmacode Industrial 25 Interleaved 25 Matrix 25 Codabar Code 93 Code 128 ISBT 128 UPC-E EAN-8 FF EAN-13 UPC-A MSI Plessey Telepen --- --- --- --- Code 11 Besides Set 1 ~ 5 of Code ID options, you can also scan the barcode below to apply AIM Code ID as the Code ID option. Apply AIM Code ID After applying AIM Code ID, three characters are added in front of the output data. “]” is always the first character. The second (Character) and third (Modifier Character) may vary depending on symbologies. Please refer to the table below. Symbology Character Modifier Character Codabar 0: Standard Codabar symbol. No special processing. Code 11 0: Single modulo 11 check character validated and transmitted 1: Two modulo 11 check characters validated and transmitted 3: Check characters validated but not transmitted 178 Enter Setup 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Chapter 5 Code 39 0: No check character validation nor full ASCII processing. All data transmitted as decoded. 1: Modulo 43 check character validated and transmitted 3: Modulo 43 check character validated but not transmitted 4: Full ASCII character conversion performed. No check character validation. 5: Full ASCII character conversion performed. Modulo 43 check character validated and transmitted. 7: Full ASCII character conversion performed. Modulo 43 check character validated but not transmitted. Code 93 No options specified. Always transmit 0. Code 128 0: Standard data packet. No FNC1 in first or second symbol character position after start character. 1: EAN/UCC-128 data packet. FNC1 in first symbol character position after start character. 2: FNC1 in second symbol character position after start character. 4: Concatenation according to International Society for Blood Transfusion specifications has been performed. Concatenated data follows. GS1 DataBar e Family No option specified at this time. Always transmit 0. GS1 DataBar and GS1 DataBar Limited transmit with an Application Identifier “01”. Interleaved 25 0: No check character validation 1: Modulo 10 symbol check character validated and transmitted 3: Modulo 10 symbol check character validated but not transmitted MSI 0: Modulo 10 symbol check character validated and transmitted 1: Modulo 10 symbol check character validated but not transmitted Matrix 25 No options specified. Always transmit 0. Plessey No options specified. Always transmit 0. Industrial 25 No options specified. Always transmit 0. Telepen No options specified. Always transmit 0. UPC/EAN 0: Standard data packet in full EAN format (13 digits for EAN-13, UPC-A, and UPC-E; does not include add-on data) 3: Combined data packet comprising 13 digits from EAN-13, UPC-A, or UPC-E symbol and 2 or 5 digits from add-on symbol 4: EAN-8 data packet 179 Update 1560/1562 Series Barcode Scanner User Guide 5.4.2 CHANGE CODE ID 1) Read the barcode below to change code ID of a specific symbology. 2) Read the “Hexadecimal Value” barcode on page 242 for the desired character string. For example, read “4” and “4” for applying the character [D] for Code ID. 3) Read the “Validate” barcode to complete this setting. Configure Code ID for Codabar Configure Code ID for Code 39 Configure Code ID for Trioptic Code 39 Configure Code ID for Code 93 Configure Code ID for Code 128 Configure Code ID for ISBT 128 Configure Code ID for EAN-8 Configure Code ID for EAN-13 Configure Code ID for French Pharmacode Configure Code ID for Italian Pharmacode 180 Enter Setup Chapter 5 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Configure Code ID for Industrial 25 Configure Code ID for Interleaved 25 Configure Code ID for Matrix 25 Configure Code ID for MSI Configure Code ID for Plessey Configure Code ID for Telepen Configure Code ID for UPC-A Configure Code ID for UPC-E Configure Code ID for Code 11 5.4.3 CLEAR CODE ID SETTINGS Clear All Code ID Settings 181 Update 1560/1562 Series Barcode Scanner User Guide 5.5 LENGTH CODE A two-digit code representing the length of barcode data (character count) can be inserted in front of data being transmitted. Such "Length" code can be individually enabled or disabled for each symbology. Length Code for Codabar Apply *Do Not Apply Length Code for Code Code 39 Apply *Do Not Apply Length Code for Trioptic Code 39 Apply *Do Not Apply Length Code for Code 93 Apply *Do Not Apply Length Code for Code 128 182 Enter Setup Chapter 5 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Apply *Do Not Apply Length Code for GS1GS1-128 & GS1 DataBar DataBar Apply *Do Not Apply Length Code for ISBT 128 Apply *Do Not Apply Length Code for EANEAN-8 Apply *Do Not Apply Length Code for EANEAN-13 Apply *Do Not Apply 183 Update 1560/1562 Series Barcode Scanner User Guide Length Code for French Pharmacode Apply *Do Not Apply Length Code for Italian Pharmacode Apply *Do Not Apply Length Code for Industrial 25 Apply *Do Not Apply Length Code for Interleaved 25 Apply *Do Not Apply Length Code for Matrix 25 Apply *Do Not Apply 184 Enter Setup Chapter 5 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Length Code for MSI Apply *Do Not Apply Length Code for Plessey Apply *Do Not Apply Length Code for Telepen Apply *Do Not Apply Length Code for UPCUPC-A Apply *Do Not Apply Length Code for UPCUPC-E Apply *Do Not Apply 185 Update 1560/1562 Series Barcode Scanner User Guide Length Code for Code 11 Apply *Do Not Apply 5.6 MULTIMULTI-BARCODE EDITOR The Multi-Barcode Editor allows you to decide the output sequence of a concatenation of barcodes. Up to five barcodes can be specified. When you enable this mode, it will force the scanner to apply Laser mode as the scan mode. Note: The Multi-Barcode Editor has nothing to do with Multi-Barcode Mode. The barcodes that are found meeting the specified criteria below will be arranged in the desired sequence. Code Type 4-digit barcode length, excluding prefix, suffix, length code, etc. Matching the first character of barcode data 186 Enter Setup Chapter 5 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 5.6.1 EDIT A CONCATENATION CONCATENATION OF BARCODES Edit Output Sequence 1) Read the barcode above to start editing a concatenation of barcodes. 2) Code Type setting – read the “Hexadecimal Value” barcode on page 242 for Code Type of the (first) barcode. For example, read “4” and “1” for Code 39. 187 Update 1560/1562 Series Barcode Scanner User Guide Code Type Symbology Code Type Symbology 40 (@) ISBT 128 4F (O) EAN-8 with Addon 5 41 (A) Code 39 50 (P) EAN-13 42 (B) Italian Pharmacode 51 (Q) EAN-13 with Addon 2 43 (C) French Pharmacode 52 (R) EAN-13 with Addon 5 44 (D) Industrial 25 53 (S) MSI 45 (E) Interleaved 25 54 (T) Plessey 46 (F) Matrix 25 55 (U) GS1-128 (EAN-128) 47 (G) Codabar (NW7) 56 (V) UPC-A 48 (H) Code 93 57 (W) UPC-A with Addon 2 49 (I) Code 128 58 (X) UPC-A with Addon 5 4A (J) UPC-E0 / UPC-E1 4B (K) UPC-E with Addon 2 5A (Z) Telepen 4C (L) UPC-E with Addon 5 5B ( [ ) GS1 DataBar (RSS) 4D (M) EAN-8 4E (N) EAN-8 with Addon 2 3) Barcode Length setting – read the “Decimal Value” barcode on page 241 for the 4-digit length of the (first) barcode. For example, read “0065” for barcode length of 65 characters or read “0000” for any length. Note: If not reading 0000 for any length, the 4-digit length must exclude prefix, suffix (0x0d by default), length code, etc. 4) Matching Character setting – read the “Hexadecimal Value” barcode on page 242 for the 1st character that must be found matching in the (first) barcode. For example, read “4” and “1” for matching character “A” as the first character in the barcode or read “00” for any character. 5) Read twice the “F” barcode on page 242 (“FF”) to complete the setting of each barcode. 6) Read the “Validate” barcode to end the editing of the barcode set. 188 Enter Setup Chapter 5 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 5.6.2 ACTIVATE THE CONCATENATION CONCATENATION OF BARCODES BARCODES By default, the output sequence editing of the concatenation of barcodes is not applied. When “Enforce Output Sequence” is enabled, all barcodes read by the scanner must meet with the criteria for the concatenation. If data is found excluded from all output sequence sets (= not meeting with the criteria), the scanner will not accept the reading, and therefore, data will not be transmitted. When “Apply Output Sequence” is enabled, only barcodes found meeting with the criteria are counted for the concatenation. Those found not meeting with the criteria are processed normally and individually. Note: When it requires reading more barcodes to complete the “output sequence” requirements, the scanner will respond with one short beep (low tone). After reading an acceptable barcode, its LED indicator will become solid green and go off quickly (= Good Read). Upon completion of reading acceptable barcodes, the scanner will respond with one short beep (high tone) and its LED indicator will become solid green and go off quickly (= Good Read). *Ignore Output Sequence Enforce Output Sequence Apply Output Sequence Warning: When you disable the Multi-Barcode Editor later, the scan mode remains unchanged. If Laser mode is not desired, proceed to select a scan mode best suits your application. 189 Update 1560/1562 Series Barcode Scanner User Guide 5.7 REMOVAL REMOVAL OF SPECIAL CHARACTER CHARACTER You can only specify 1 character, but it will remove every matching character encountered from the starting position of barcode data until a different character is met. For example, if it is configured to remove the character “0” (hex value is “30”), one or more zeros will be stripped off the barcode data “012345” and “00012345”. However, for barcode data “010333”, only the first zero will be stripped off. Remove Special Character 1) Read the barcode above to remove the specified character. 2) Read the “Hexadecimal Value” barcode on page 242 for the desired character. For example, read “3” and “0” for the scanner to remove the character “0”. 3) Read the “Validate” barcode to complete this setting. 190 Enter Setup Chapter 6 APPLYING FORMATS FOR DATA DATA EDITING The scanner allows advanced data editing by applying user-configured editing formats. The whole processed data can be divided into fields by user-specified rules. These fields together with the user-configurable additional fields consist of the data actually sent to the host computer. [Prefix Code] [Code ID] [Length Code] [Data] [Suffix Code] None by default None by default None by default Barcode itself 0x0d by default Additional Field(s) IN THIS CHAPTER 6.1 6.2 6.3 6.4 6.5 6.6 Activating Editing Formats ......................................... How to Configure Editing Formats ............................... Configuring Format — Define Data Criteria ................... Configuring Format — Define Data Field....................... Configuring Format — Define Transmission Sequence .... Programming Examples ............................................. 192 194 197 205 214 216 191 Update 1560/1562 Series Barcode Scanner User Guide 6.1 6.1 ACTIVATING EDITING FORMATS FORMATS 6.1.1 ACTIVATE EDITING EDITING FORMATS If you have already configured any editing format before, you may directly apply the editing format. If not, you must start with configuring an editing format first, and then, activate the editing format when it is desired in use. Editing Format 1 Enable *Disable Editing Format 2 Enable *Disable Editing Format 3 Enable *Disable Editing Format 4 Enable *Disable 192 End Programming Format Chapter 6 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Editing Format 5 Enable *Disable 6.1.2 EXCLUSIVE DATA EDITING EDITING By default, only barcodes found meeting with the criteria are processed by the editing formats. Those found not meeting with the criteria are processed normally. When “Exclusive Data Editing” is enabled, all barcodes read by the scanner must be processed by the editing formats. If data is found excluded from all enabled editing formats (= not meeting with the specified criteria), the scanner will not accept the reading, and therefore, data will not be transmitted. Yes *No 193 Update 1560/1562 Series Barcode Scanner User Guide 6.2 6.2 HOW TO CONFIGURE EDITING FORMATS FORMATS 194 End Programming Format Chapter 6 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 6.2.1 SELECT FORMAT TO CONFIGURE Start Programming Format Select one editing format (Format 1~5) and the parameters pertaining to the editing format can then be configured – applicable code type, data length, matching string & location, start position, field adjustment, total number of fields, field settings (field-dividing rule), additional fields, and field transmission sequence. Up to five different formats can be specified. Configure Format 1 Configure Format 2 Configure Format 3 Configure Format 4 Configure Format 5 Note: Before you complete the programming of an editing format, if you have the scanner read any barcode for parameters other than those pertaining to the editing format, it will automatically abort the programming process. End Programming Format After having configured all the desired parameters, you must have the scanner read the “End Programming Format” barcode, which can be located at the bottom of every even page in this chapter. End Programming Format 195 Update 1560/1562 Series Barcode Scanner User Guide 6.2.2 RESTORE DEFAULT FORMAT FORMAT You may select an existing editing format and have the defaults restored. The default settings of an editing format are listed below. Editing format Defaults Applicable Code Type All Data Length 0 (No qualification) Matching String Disable Matching String Location None Start Position From head Field Adjustment No adjustment Total Number of Fields Field Setting – field-dividing rule Not configured Additional Fields None Field Transmission Sequence F1 Restore Default Format 196 End Programming Format Chapter 6 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 6.3 CONFIGURING FORMAT FORMAT — DEFINE DATA CRITERIA Three applicable conditions can be configured to check whether the data read by the scanner can be processed by the particular editing format. Note: Data editing cannot be performed unless the three conditions are all met. 6.3.1 APPLICABLE CODE CODE TYPE By default, barcodes of all the supported symbologies will be processed by any editing format, if having been configured and enabled. For quick configuration, you may first clear all, and then select the desired symbologies. Note: You must have at least one symbology selected. *Apply to All Clear All 197 Update 1560/1562 Series Barcode Scanner User Guide Editing Format for Codabar *Apply Do Not Apply Editing Format for Code 39 *Apply Do Not Apply Editing Format for Trioptic Code 39 *Apply Do Not Apply Editing Editing Format for Code 93 *Apply Do Not Apply Editing Format for Code 128 *Apply Do Not Apply 198 End Programming Format Chapter 6 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Editing Format for GS1GS1-128 & GS1 DataBar *Apply Do Not Apply Editing Format for ISBT 128 *Apply Do Not Apply Editing Editing Format for EANEAN-8 *Apply Do Not Apply Editing Format for EANEAN-8 Addon 2 *Apply Do Not Apply Editing Format for EANEAN-8 Addon 5 *Apply Do Not Apply 199 Update 1560/1562 Series Barcode Scanner User Guide Editing Format for EANEAN-13 *Apply Do Not Apply Editing Format Format for EANEAN-13 Addon 2 *Apply Do Not Apply Editing Format for EANEAN-13 Addon 5 *Apply Do Not Apply Editing Format for French Pharmacode *Apply Do Not Apply Editing Format for Italian Pharmacode *Apply Do Not Apply 200 End Programming Format Chapter 6 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字 套用到您想要在此處顯示的文字。 您想要在此處顯示的文字。 Editing Format for Industrial 25 *Apply Do Not Apply Editing Format for Interleaved 25 *Apply Do Not Apply Editing Format for Matrix 25 *Apply Do Not Apply Editing Format for MSI *Apply Do Not Apply Editing Format for Plessey *Apply Do Not Apply 201 Update 1560/1562 Series Barcode Scanner User Guide Editing Format for Telepen *Apply Do Not Apply Editing Format for UPCUPC-A *Apply Do Not Apply Editing Format for UPCUPC-A Addon 2 *Apply Do Not Apply Editing Format for UPCUPC-A Addon 5 *Apply Do Not Apply Editing Format for UPCUPC-E *Apply Do Not Apply 202 End Programming Format Chapter 6 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Editing Format for UPCUPC-E Addon 2 *Apply Do Not Apply Editing Format for UPCUPC-E Addon 5 *Apply Do Not Apply Editing Format for Code 11 *Apply Do Not Apply 203 Update 1560/1562 Series Barcode Scanner User Guide 6.3.2 DATA LENGTH The length must include prefix, suffix (0x0d by default), length code, etc. By default, barcodes of any length (character count) are eligible for data editing. You may specify a value from 0 to 254. When zero is given to both, the scanner will not perform the length qualification. 1) Read the barcode below to specify Max. Length or Min. Length separately, and follow steps 2~3. Max. Length Min. Length 2) Read the “Decimal Value” barcode on page 241 for the desired length. 3) Read the “Validate” barcode on the same page to complete this setting. 204 End Programming Format Chapter 6 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 6.3.3 MATCHING STRING STRING & LOCATION By default, no matching string is specified, and therefore, it is disabled. You may enable this feature by specifying a matching string; up to four characters are allowed. When the Matching String Location is zero, the scanner will only check for the existence of the matching string in the barcode data. You may specify a value from 1 to 254 to indicate where the matching string starts in the barcode data. 1) Read the barcode to specify a matching string. Matching String… 2) Read the “Hexadecimal Value” barcode on page 242 for the desired character string. 3) Read the “Validate” barcode to complete this setting. 4) Read the barcode to specify the location of the matching string. Location of Matching String… 5) Read the “Decimal Value” barcode on page 241 for the desired location. 6) Read the “Validate” barcode on the same page to complete this setting. 6.4 CONFIGURING FORMAT FORMAT — DEFINE DATA DATA FIELD 6.4.1 START POSITION Data can be divided into fields in one of the following direction – from head (F1) to tail (F5) from tail (F1) to head (F5) *From Head From Tail 205 Update 1560/1562 Series Barcode Scanner User Guide 6.4.2 FIELD ADJUSTMENT You may apply equal length to all fields, if necessary. If data is found longer than specified, it will be truncated automatically. When data is found shorter, it will add “Space” (0x20) to field. *No adjustment Set length to adjust fields… (*0) 1) Read the barcode above to adjust field by length. 2) Read the “Decimal Value” barcode on page 241 for the desired field length. 3) Read the “Validate” barcode on the same page to complete this setting. 6.4.3 TOTAL NUMBER OF FIELDS Data can be divided into at most 6 fields; each of them is numbered from F1 to F6 accordingly. However, only F1~F5 can be configured. The total number of fields must be specified correctly. If three fields are configured for the editing format, the data characters after F3 will be assigned to F4 automatically. This feature is quite useful especially when data of variable lengths is processed by editing formats. *One Field Two Fields Three Fields Four Fields 206 End Programming Format Chapter 6 錯誤! 使用 [常用] 索引標籤將 Heading Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Five Fields Six Fields Note: The number of configurable fields is always one less than the total number of fields specified. The extra data characters beyond the last field configured will be automatically assigned to the next field. 6.4.4 6.4.4 FIELD SETTINGS Data eligible for editing formats is divided into fields by user-specified rules – either using the field terminating string or specified field length. By Terminating String Specify the field terminating string. Up to two characters are allowed. The scanner will search for the occurrence of this particular string in the data. By default, this string will be included in the field. You may discard it. By Length Alternatively, you may simply specify the field length. The scanner will assign the next specified number of characters into the field. Field 1 Setting 1. Read the barcode below to divide field 1 by a specified terminating string. Select Field Separator to Divide Field 1… 2. Read the “Hexadecimal Value” barcode on page 242 for the desired character string. 3. Read the “Validate” barcode to complete this setting. 4. Read the “Discard Separator” barcode if the field separator is not desired in the field. *Include Separator Discard Separator 207 Update 1560/1562 Series Barcode Scanner User Guide If not dividing the field by a specific separator, you may divide it by a specified length. 1. Read the barcode below to divide field 1 by length. Divide Field 1 by Length 2. Read the “Decimal Value” barcode on page 241 for the desired field length. 3. Read the “Validate” barcode on the same page to complete this setting. Field 2 Setting 1. Read the barcode below to divide field 2 by a specified terminating string. Select Field Separator to Divide Field 2… 2. Read the “Hexadecimal Value” barcode on page 242 for the desired character string. 3. Read the “Validate” barcode to complete this setting. 4. Read the “Discard Separator” barcode if the field separator is not desired in the field. *Include Separator Discard Separator If not dividing the field by a specific separator, you may divide it by a specified length. 1. Read the barcode below to divide field 2 by length. Divide Field 2 by Length 2. Read the “Decimal Value” barcode on page 241 for the desired field length. 3. Read the “Validate” barcode on the same page to complete this setting. 208 End Programming Format Chapter 6 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Field 3 Setting 1. Read the barcode below to divide field 3 by a specified terminating string. Select Field Separator to Divide Field 3… 2. Read the “Hexadecimal Value” barcode on page 242 for the desired character string. 3. Read the “Validate” barcode to complete this setting. 4. Read the “Discard Separator” barcode if the field separator is not desired in the field. *Include Separator Discard Separator If not dividing the field by a specific separator, you may divide it by a specified length. 1. Read the barcode below to divide field 3 by length. Divide Field 3 by Length 2. Read the “Decimal Value” barcode on page 241 for the desired field length. 3. Read the “Validate” barcode on the same page to complete this setting. 209 Update 1560/1562 Series Barcode Scanner User Guide Field 4 Setting 1. Read the barcode below to divide field 4 by a specified terminating string. Select Field Separator to Divide Field 4… 2. Read the “Hexadecimal Value” barcode on page 242 for the desired character string. 3. Read the “Validate” barcode to complete this setting. 4. Read the “Discard Separator” barcode if the field separator is not desired in the field. *Include Separator Discard Separator If not dividing the field by a specific separator, you may divide it by a specified length. 1. Read the barcode below to divide field 4 by length. Divide Field 4 by Length 2. Read the “Decimal Value” barcode on page 241 for the desired field length. 3. Read the “Validate” barcode on the same page to complete this setting. 210 End Programming Format Chapter 6 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Field 5 Setting 1. Read the barcode below to divide field 5 by a specified terminating string. Select Field Separator to Divide Field 5… 2. Read the “Hexadecimal Value” barcode on page 242 for the desired character string. 3. Read the “Validate” barcode to complete this setting. 4. Read the “Discard Separator” barcode if the field separator is not desired in the field. *Include Separator Discard Separator If not dividing the field by a specific separator, you may divide it by a specified length. 1. Read the barcode below to divide field 5 by length. Divide Field 5 by Length 2. Read the “Decimal Value” barcode on page 241 for the desired field length. 3. Read the “Validate” barcode on the same page to complete this setting. 211 Update 1560/1562 Series Barcode Scanner User Guide Additional Fields Up to five additional fields can be created for each editing format; each of them is numbered from AF1 to AF5 accordingly. If “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type. Key Type Key Status Scan Code Up to 2 scan code values are allowed. Normal Key Up to 4 character strings are allowed. N/A Add Shift Add Left Ctrl Add Left Alt Add Right Ctrl Add Right Alt Refer to Keyboard Wedge Table. 1. Read the barcode below to specify an additional field, one at a time. Additional Field 1… Additional Field 2… Additional Field 3… Additional Field 4… Additional Field 5… 2. Read the “Hexadecimal Value” barcode on page 242 for the desired additional field. 3. Read the “Validate” barcode to complete this setting. 212 End Programming Format Chapter 6 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 6.4.5 PAUSE FIELD SETTING SETTING Pause Field Time You can limit the pause time interval (1~16). By default, it is set to 1 second. Pause Field Time 1~16 sec. (*1) 1. Read the barcode above to specify the time interval for the Pause Field. (It is set to 1 by default.) 2. Read the “Decimal Value” barcode on page 241. For example, read “1” and “0” for setting the Pause Field Time to 10 seconds. 3. Read the “Validate” barcode on the same page to complete this setting. 213 Update 1560/1562 Series Barcode Scanner User Guide 6.5 CONFIGURING FORMAT FORMAT — DEFINE TRANSMISSION SEQUENCE After configuring the data fields and additional fields, you must now program the transmission sequence of these fields that comprise the final data. This field transmission sequence can be assigned in any desired order and fields can be assigned multiple times as well. Note: Up to twelve fields can be assigned. 1) Read the “Start” barcode to begin with programming the field transmission sequence. Start Programming… 2) Program the transmission sequence by reading the desired fields as well as additional fields. Field 1 Field 2 Field 3 Field 4 Field 5 Field 6 Additional Field 1 Additional Field 2 214 End Programming Format Chapter 6 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Additional Field 3 Additional Field 4 Additional Field 5 Pause Field Null Character Field 3) Read the “End” barcode to complete this setting. End Programming… 215 Update 1560/1562 Series Barcode Scanner User Guide 6.6 6.6 PROGRAMMING EXAMPLES 6.6 6.6.1 EXAMPLE I Extract data from the 10th character to the 19th character... The editing format should be configured as follows: 1. Read the “Enter Setup” barcode to enter the Configuration Mode. 2. Read the “Configure Format 1” barcode. 3. Read the “Clear All” and “Code 128” barcodes for applicable code type. 4. Read the “Three Fields” barcode. 5. Read the “Divide Field 1 by Length” barcode, and set length to 9. Field 1 data starts from the 1st character to the 9th character. 6. Read the “Divide Field 2 by Length” barcode, and set length to 10. Field 2 data starts from the 10th character to the 19th character. 7. Read the “Start (Programming)” barcode to program the transmission sequence. 8. Read the “Field 2” barcode. 9. Read the “End” barcode to complete the transmission sequence setting. 10. Read the “End Programming Format” barcode to complete the setting of Editing Format 1. 11. Read the “Enable Format 1” barcode to apply Editing Format 1 to Code 128. 12. Read the “Update” barcode to exit the Configuration Mode. 216 End Programming Format Chapter 6 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 6.6.2 EXAMPLE II Extract the date code, item number, and quantity information from barcodes. Data in a barcode is encoded like this: From the 1st character to the 6th character is the date code. From the 7th character to the dash ‘-’ character is the item number. After the dash ‘-’ character is the quantity information. Data will be transmitted like this: The item number goes first, then a TAB character, followed by the date code, then another TAB character, and finally the quantity information. The editing format should be configured as follows: 1. Read the “Enter Setup” barcode to enter the Configuration Mode. 2. Read the “Configure Format 2” barcode. 3. Read the “Three Fields” barcode. 4. Read the “Divide Field 1 by Length” barcode, and set length to 6. Field 1 data starts from the 1st character to the 6th character. 5. Read the “Select Field Separator to Divide Field 2” barcode, and use a dash ‘-’ character. Field 2 data starts from the 7th character until the dash ‘-’ character is met. 6. Read the “Additional Field 1” barcode, and use a tab character for the field. 7. Read the “Start (Programming)” barcode to program the transmission sequence. 8. Read the “Field 2”, “Additional Field 1”, “Field 1”, “Additional Field 1”, “Field 3” barcodes. 9. Read the “End” barcode to complete the transmission sequence (F2 A1 F1 A1 F3) setting. 10. Read the “End Programming Format” barcode to complete the setting of Editing Format 1. 11. Read the “Enable Format 2” barcode to apply Editing Format 2 to all code types. 12. Read the “Update” barcode to exit the Configuration Mode. 217 Update 1560/1562 Series Barcode Scanner User Guide 218 End Programming Format SPECIFICATIONS Optical Characteristics Characteristics 1560 1562 Scan Engine Non-contact type Non-contact type Optical Sensor CCD, 2500 pixels Laser Light Source Visible red LED Visible laser diode RF Characteristics WPAN Module Wireless PAN BT Class 2 compliance Coverage (line-of-sight) 90 meters with 3656 CRADLE Interface Supported Serial Port Profile (BT SPP) Human Interface Device Profile (BT HID) 3656 CRADLE Physical Characteristics Memory 4 KB for transmit buffer 512 KB flash for memory mode Switch Tactile switch Indication Triple-color LED (Red/Green/Blue) and beeper Weight Approx. 170 g Approx. 175 g 219 Update 1560/1562 Series Barcode Scanner User Guide Electrical Characteristics Battery Rechargeable Li-ion battery – 3.7 V, 800 mAh Power Adapto Adaptor Input AC 100~240 V, 50/60 Hz Output DC 5V, 2A (3656 CRADLE) DC 5V 0.5A (Battery Charger) Operating Temperature 0 °C to 40 °C Environmental Characteristics Temperature Humidity (Non-condensing) Operating 0 °C to 50 °C Storage -20 °C to 60 °C Operating 10% to 90% Storage 5% to 95% Resistance Impact Resistance 1.2 m, 5 drops per 6 sides Splash / Dust Resistance IP 30 Electrostatic Discharge ± 15 kV air discharge, ± 8 kV contact discharge Programming Support Configuration via Setup Barcodes Use setup barcodes or host serial commands. Software Windows®-based ScanMaster Firmware upgradeable Download firmware updates via the download utility. Accessories (√ (√ means “supported”) Rechargeable Li-ion Battery √ √ Battery Charger √ √ 3656 CRADLE Stand √ √ USB Cable √ √ RS-232 Cable √ √ Keyboard Wedge Cable √ √ Note: The 3656 CRADLE stand is not only an Auto-Sense stand (for 1560 only) and capable of charging the 1560/1562 scanner, but specifically designed for the scanner to communicate with a host computer wirelessly. 220 Enter Setup Appendix I FIRMWARE UPGRADE UPGRADE You can only upgrade firmware of one scanner at a time. For example, you must turn off each of the rest 1560/1562 scanners when there is more than one scanner connected to your computer. Note: In case it fails downloading due to low battery, make sure the targe scanner is loaded with good battery and the battery charge is enough. HOW TO UPGRADE 1560/1562 1560/1562 FIRMWARE USING 3656 CRADLE 1) Connect the interface cable, RS-232 or USB, between 3656 CRADLE and your computer. For USB Virtual COM, you may need to install its driver first! 2) Connect the power supply cord from 3656 CRADLE to a proper power outlet. 3) Refer to 3.1.1 Connect to for the target scanner to connect to 3656 CRADLE. Read the “Set Connection” label first, and then the “Serial Number” label. Both labels can be located at the back of 3656 CRADLE. 4) Read the following barcodes in sequence to configure the scanner to use RS-232 as download interface. Enter Setup Activate 3656 CRADLE RS-232 115200 bps Update Or, read the following barcodes in sequence to configure the scanner to use USB Virtual COM as download interface. 221 Update 1560/1562 Series Barcode Scanner User Guide Enter Setup Activate 3656 CRADLE USB Virtual COM Update 5) Read the following barcodes in sequence for the scanner to enter the download mode. The scanner will respond with beeps to indicate it is ready for downloading. Enter Setup Download 6) Run the download utility “ProgLoad.exe” on your computer. Kernel Program User Program K1560_V*.shx STD1560_V*.shx For the communication settings, select “RS-232” and the correct COM port for RS-232 or USB Virtual COM interface. For RS-232, select 115200 bps for baud rate; for USB Virtual COM, ignore the baud rate setting. For the file option, click [Browse] to select the target file for firmware update. Click [OK]. 7) After upgrading kernel, you will need to manually restart the scanner. After upgrading the user program, the scanner will automatically restart itself once the download is completed successfully. 222 Enter Setup Appendix I 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Note: The output interface remains unchanged as specified in step 3 (= RS-232 or USB Virtual COM). For RS-232, the baud rate setting is still 115200 bps! 223 Update 1560/1562 Series Barcode Scanner User Guide USING BLUETOOTH® DONGLE 1) Refer to 3.2.3 Connect to Dongle for the target scanner to accept the connection request from your computer. 2) Read the following barcodes in sequence to configure the scanner to use BT SPP as download interface. Enter Setup Activate BT SPP Update 3) Read the following barcodes in sequence for the scanner to enter the download mode. The scanner will respond with beeps to indicate it is ready for downloading. Enter Setup Download 4) Run the download utility “ProgLoad.exe” on your computer. Kernel Program User Program K1560_V*.shx STD1560_V*.shx 224 Enter Setup Appendix I 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 For the communication settings, select “RS-232” and the correct COM port for BT SPP interface. Ignore the baud rate setting. For the file option, click [Browse] to select the target file for firmware update. Click [OK]. 5) After upgrading kernel, you will need to manually restart the scanner. After upgrading the user program, the scanner will automatically restart itself once the download is completed successfully. Note: The output interface remains unchanged as specified in step 2 (= BT SPP). 225 Update 1560/1562 Series Barcode Scanner User Guide HOW TO UPGRADE 3656 CRADLE FIRMWARE UPGRADING 3656 CRADLE CPU FIRMWARE 1) Connect the interface cable, RS-232 or USB, between 3656 CRADLE and your computer. For USB Virtual COM, you may need to install its driver first! 2) Connect the power supply cord from 3656 CRADLE to a proper power outlet. 3) Refer to 3.1.1 Connect to for the target scanner to connect to 3656 CRADLE. Read the “Set Connection” label first, and then the “Serial Number” label. Both labels can be located at the back of 3656 CRADLE. 4) Read the following barcodes in sequence to configure the scanner to use RS-232 as download interface. Enter Setup Activate 3656 CRADLE RS-232 Update Or, read the following barcodes in sequence to configure the scanner to use USB Virtual COM as download interface. Enter Setup Activate 3656 CRADLE USB Virtual COM Update 5) Read the following barcodes in sequence for 3656 CRADLE to enter the download mode. The Communication LED on 3656 CRADLE will be flashing red to indicate it is ready for downloading. 226 Enter Setup Appendix I 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Enter Setup Download 3656 CRADLE CPU Firmware 6) Run the download utility “ProgLoad.exe” on your computer. Kernel Program User Program K3656 CRADLE _V*.shx STD3656 CRADLE _V*.shx For the communication settings, select “RS-232” and the correct COM port for RS-232 or USB Virtual COM interface. For RS-232, select 115200 bps for baud rate; for USB Virtual COM, ignore the baud rate setting. For the file option, click [Browse] to select the target file for firmware update. Click [OK]. 7) The 3656 CRADLE will automatically restart itself when upgrading firmware is completed successfully. 8) Read the “Update” barcode for the scanner to resume its operation (exit the configuration mode). Update 227 Update 1560/1562 Series Barcode Scanner User Guide UPGRADING 3656 CRADLE USB BRIDGE FIRMWARE 1) Connect the USB cable between 3656 CRADLE and your computer. For USB Virtual COM, you may need to install its driver first! 2) Connect the power supply cord from 3656 CRADLE to a proper power outlet. 3) Refer to 3.1.1 Connect to for the target scanner to connect to 3656 CRADLE. Read the “Set Connection” label first, and then the “Serial Number” label. Both labels can be located at the back of 3656 CRADLE. 4) Read the following barcodes in sequence to configure the scanner to use USB Virtual COM as download interface. Enter Setup Activate 3656 CRADLE USB Virtual COM Update Note: You can download USB Bridge firmware via USB Virtual COM only! 5) Read the following barcodes in sequence for 3656 CRADLE to enter the download mode. The Communication LED on 3656 CRADLE will be flashing red to indicate it is ready for downloading. Enter Setup Download 3656 CRADLE USB Bridge Firmware 6) Run the download utility “ProgLoad.exe” on your computer. Kernel Program User Program K3656 CRADLE Bridge_V*.shx STD3656 CRADLE Bridge_V*.shx 228 Enter Setup Appendix I 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 For the communication settings, select “RS-232” and the correct COM port for USB Virtual COM interface. Ignore the baud rate setting. For the file option, click [Browse] to select the target file for firmware update. Click [OK]. 7) The 3656 CRADLE will automatically restart itself when upgrading firmware is completed successfully. 8) Read the “Update” barcode for the scanner to resume its operation (exit the configuration mode). Update 229 Update 1560/1562 Series Barcode Scanner User Guide 230 Enter Setup Appendix II HOST SERIAL SERIAL COMMANDS 1560/1562 1560/1562 SERIAL COMMANDS Purpose To disable the scanner. Remarks “D” Purpose To enable the scanner. Remarks “E” #@ nnnnnnPurpose To configure the scanner. Remarks nnnnnn – the six digits of command parameters. For example, “109952” is to list the current Code ID settings. List Page 3 Serial Command “0x23” + “0x40” + “0x31” + “0x30” + “0x39” + “0x39” + “0x35” + “0x32” + “0x0d” Note: After configuring the scanner, you may send the serial command “#@109999” to save the settings. #@ - - - - Purpose To halt the scanner. Remarks “0x23” + “0x40” + “0x2d” + “0x2d” + “0x2d” + “0x2d” + “0x0d” #@ . . . . Purpose To resume operation. Remarks “0x23” + “0x40” + “0x2e” + “0x2e” + “0x2e” + “0x2e” + “0x0d” #@//// Purpose To respond with a beep. Remarks “0x23” + “0x40” + “0x2f” + “0x2f” + “0x2f” + “0x2f” + “0x0d” 231 Update 1560/1562 Series Barcode Scanner User Guide #@TRIGOFF Purpose To disable the software trigger Remarks “0x23” + “0x40” + “0x54” + “0x52” + “0x49” + “0x47” + “0x4f” + “0x46” + “0x46” + “0x0d” #@TRIGON Purpose To enable the software trigger Remarks “0x23” + “0x40” + “0x54” + “0x52” + “0x49” + “0x47” + “0x4f” + “0x4e” + “0x0d” #@RDSN #@RDSN RDSN Purpose Read serial number Remarks “0x23” + “0x40” + “0x52” + “0x44” + “0x53” + “0x4E” + “0x0D” EXAMPLE You may run HyperTerminal.exe on the host computer to send serial commands to the 1560/1562 scanner via RS-232, USB Virtual COM or BT SPP. For the scanner to stop immediately – For the scanner to resume working – For the scanner to change the beeper to medium volume and beep – #@101011 #@//// For the scanner to change the beeper to minimal volume and beep – #@101010 #@//// For the scanner to change the beeper frequency to 8 kHz (for Good Read Beep only) and beep – #@101001 #@//// For the scanner to change the beeper length to longest (for Good Read Beep only) and beep – #@101008 #@//// For the scanner to save the settings, send the serial command “#@109999” – #@101011 #@109999 232 Enter Setup Appendix II 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 For the scanner to read the serial number and beep – #@RDSN #@//// Note: (1) For RS-232 or USB Virtual COM, you can only configure the first scanner that connects to 3656 CRADLE. To identify the scanner, you may send the serial command to have it respond with a beep. (2) For BT SPP, you can configure up to seven scanners at the same time. 3656 CRADLE SETUP BARCODES BARCODES & SERIAL COMMANDS Normally, you can configure the 3656 CRADLE stand by having a connected scanner read 3656 CRADLE -related setup barcodes. 1) Connect the interface cable, RS-232, Keyboard Wedge or USB, between 3656 CRADLE and your computer. For USB Virtual COM, you may need to install its driver first! 2) Connect the power supply cord from 3656 CRADLE to a proper power outlet. 3) Refer to 3.1.1 Connect to for the target scanner to connect to 3656 CRADLE. Read the “Set Connection” label first, and then the “Serial Number” label. Both labels can be located at the back of 3656 CRADLE. 4) Read the following barcodes in sequence to configure 3656 CRADLE. Enter Setup (3656-related setup barcodes) Update For 3656 CRADLE -related setup barcodes, refer to the Serial Command table below. Note that for the “Version” and “GetID” barcodes, you must run HyperTerminal.exe or any text editor to receive the information. If the output interface is RS-232 or USB Virtual COM, run HyperTerminal.exe on your computer to receive the information. If the output interface is Keyboard Wedge or USB HID, run any text editor to receive the information. 233 Update 1560/1562 Series Barcode Scanner User Guide 3656 CRADLE SETUP BARCODES Config Config Purpose To configure 3656 CRADLE. Here is the setup barcode for this serial command: Config Remarks A list of the current settings will be displayed. Run HyperTerminal.exe on your computer and change the settings one by one. DefaultSetting DefaultSetting Purpose To restore the default settings. Here is the setup barcode for this serial command: DefaultSetting SingleConnection SingleConnection Purpose To allow only one scanner connecting to 3656 CRADLE. Here is the setup barcode for this serial command: SingleConnection MultiCon MultiConnection Connection nection Purpose To allow up to seven scanners connecting to 3656 CRADLE. Here is the setup barcode for this serial command: MultiConnection UseOnePortforAll UseOnePortforAll Purpose To use one Virtual COM port for all whenever connecting 3656 CRADLE to PC via USB. This setting requires you to connect one 3656 CRADLE at a time, and will facilitate configuring a great amount of 3656 CRADLE via the same Virtual COM port (for administrators’ or factory use). Here is the setup barcode for this serial command: UseOnePortforAll 234 Enter Setup Appendix II 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 UseVariablePort UseVariablePort Purpose To use variable Virtual COM port when connecting more than one 3656 CRADLE to PC via USB. Here is the setup barcode for this serial command: UseVariablePort Version Version Purpose To get the firmware versions (CPU+USB Bridge). Here is the setup barcode for this serial command: Version GetID GetID Purpose To get MAC ID. Here is the setup barcode for this serial command: GetID Download Download Purpose To download CPU firmware to 3656 CRADLE via RS-232 or USB. Here is the setup barcode for this serial command: Download LoadBridge LoadBridge Purpose To download USB Bridge firmware to 3656 CRADLE via USB only. Here is the setup barcode for this serial command: LoadBridge 235 Update 1560/1562 Series Barcode Scanner User Guide EXAMPLE Without using the scanner to read the above setup barcodes for configuring the 3656 CRADLE stand, you may run HyperTerminal.exe on the host computer to send serial commands to 3656 CRADLE via RS-232 or USB. 1) Connect the interface cable, RS-232 or USB, between 3656 CRADLE and your computer. For USB Virtual COM, you may need to install its driver first! 2) Connect the power supply cord from 3656 CRADLE to a proper power outlet. The Communication LED will indicate when 3656 CRADLE can accept serial commands after initializing. Refer to the table below. If the output interface is USB Virtual COM or RS-232, run HyperTerminal.exe on your computer. While the Communication LED on 3656 CRADLE is purple (red with flashing blue), type the serial command within three seconds. If the output interface is USB HID, press the “Num Lock” or “Caps Lock” key on your keyboard 5 times within 3 seconds while the Communication LED on 3656 CRADLE is flashing red and blue. This will change the interface from USB HID to USB Virtual COM and the Communication LED will become purple (red with flashing blue). Then, run HyperTerminal.exe on your computer. While the Communication LED on 3656 CRADLE is purple (red with flashing blue), type the serial command within three seconds. After configuring via serial commands, the interface will be reset to USB HID after re-connecting the power supply cord. Communication LED Meaning --- Blue, solid Initialize Red, solid Blue, flashing Serial command mode with USB Virtual COM or RS-232: wait 3 seconds for starting a serial command Red, flashing Blue, flashing Serial command mode with USB HID changed to USB Virtual COM first: wait 3 seconds for pressing [Num Lock] or [Caps Lock] 5 times via keyboard 236 Enter Setup Appendix III KEYBOARD WEDGE TABLE F2 SP INS F3 DLT F4 Home F5 End F6 Up F7 Down F8 Left F9 BS F10 HT F11 LF F12 Right ESC PgUp Exec CR CR* PgDn F1 Dly ENTER* Note: (1) ~ : Digits of numeric keypad. (2) CR*/ENTER*: ENTER key on the numeric keypad. 237 Update 1560/1562 Series Barcode Scanner User Guide KEY TYPE & STATUS KEY TYPE If “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. *Normal Scan Code KEY STATUS Decide whether or not to change key status when “Normal Key” is selected for Key Type. Add Shift Add Left Ctrl Add Right Ctrl Add Left Alt Add Right Alt 238 Enter Setup Appendix III 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 EXAMPLE KEY TYPE = NORMAL For example, if you want to program the character “!” as the prefix code: 1. Read the “Configure Prefix” barcode. 2. Read the “Hexadecimal Value” barcode on page 242 for “2” and “1”. 3. Read the “Validate” barcode to complete this setting. KEY TYPE = SCAN CODE For example, if you want to program the character “a” (= “1C” on the scan code table) as the prefix code: 1. Read the “Configure Prefix” barcode. 2. Read the “Scan Code” barcode. 3. Read the “Hexadecimal Value” barcode on page 242 for “1” and “C”. 4. Read the “Validate” barcode to complete this setting. KEY TYPE = NORMAL + KEY STATUS = SHIFT For example, if you want to program the character “!” (= “Shift” + “1” on keyboard) as the prefix code: 1. Read the “Configure Prefix” barcode. 2. Read the “Add Shift” barcode. 3. Read the “Hexadecimal Value” barcode on page 242 for “3” and “1”. 4. Read the “Validate” barcode to complete this setting. KEY TYPE = NORMAL + KEY STATUS = CTRL For example, if you want to program “Ctrl+A” and “Ctrl+$” as the prefix code: 1. Read the “Configure Prefix” barcode. 2. Read the “Add Left Ctrl” barcode. 3. Read the “Hexadecimal Value” barcode on page 242 for “4”, “1” (= “A”). 4. Read the “Add Left Ctrl” barcode. 5. Read the “Hexadecimal Value” barcode on page 242 for “2”, “4” (= “$”). 6. Read the “Validate” barcode to complete this setting. 239 Update 1560/1562 Series Barcode Scanner User Guide 240 Enter Setup Appendix IV NUMERAL SYSTEMS DECIMAL SYSTEM Decimal Validate the Values Validate Update Abort 241 1560/1562 Series Barcode Scanner User Guide HEXADECIMAL SYSTEM SYSTEM Hexadecimal 242 Enter Setup Appendix IV 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 Validate the Values Validate ASCII TABLE DLE SP SOH DC1 STX DC2 ETX DC3 EOT DC4 ENQ NAK ACK SYN BEL ETB BS CAN HT EM LF SUB VT ESC FF FS CR GS SO RS SI US DEL Update Abort 243 1560/1562 Series Barcode Scanner User Guide ENTERING ENTERING PIN CODE FOR AUTHENTICATION USE PRESET PIN 1) In the configuration mode, read the barcode below to use a preset PIN for authentication. Use Preset PIN 2) Read one of the barcodes to specify the PIN code, in decimal or hexadecimal. By default, the PIN code is set to “0000”. Maximum 16 characters are allowed. Enter PIN in Hexadecimal… Enter PIN in Decimal… 3) Read the “Decimal Value” barcode on page 241 or the “Hexadecimal Value” barcode on page 242 for the desired digits or character string. Read the “Clear PIN Code” barcode first if you need to re-input the PIN code. Clear PIN Code 4) Read the “Validate” barcode to complete this setting. 244 Enter Setup Appendix IV 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。 套用到您想要在此處顯示的文字。 DISABLE AUTHENTICATION OR USE USE RANDOM PIN In the configuration mode, read the barcode below to disable authentication (= No PIN) or use a random PIN for authentication. *No PIN or use random PIN Note: When using BT HID, some device driver may not support pre-defined PIN code for authentication. In this case, make sure you have the scanner set to “No PIN or use random PIN” before pairing. While pairing, the host PIN code will be displayed on the computer screen. Use Random PIN When the target device is set to use a random PIN for authentication, wait until the random PIN is displayed on the target device while pairing, and then input the matching PIN code on the scanner. Note: Follow the steps below to enter the matching PIN on the scanner. There is no need to enter the configuration mode! 1. Read one of the barcodes to specify the PIN code, in decimal or hexadecimal. Enter PIN in Hexadecimal… Enter PIN in Decimal… 2. Read the “Decimal Value” barcode on page 241 or the “Hexadecimal Value” barcode on page 242 for the desired digits or character string. Read the “Clear PIN Code” barcode first if you need to re-input the PIN. Clear PIN Code 3. Read the “Validate” barcode to complete this setting. Reject Random PIN Request When the random PIN is displayed on the target device while pairing, you can reject the PIN request by having the scanner read the “Validate” barcode. Update Abort 245
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : gary.lin Create Date : 2018:04:30 17:32:52+08:00 Modify Date : 2018:05:29 18:53:47+08:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Producer : GPL Ghostscript 9.06 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2018:05:29 18:53:47+08:00 Document ID : uuid:f42749f7-4eb4-11e8-0000-06a0ce70e880 Instance ID : uuid:a9d625ae-b843-4a36-8c22-6977e6d8537f Format : application/pdf Title : Microsoft Word - 1560_1562 Series Scanner User Guide_v1.21 Creator : gary.lin Page Count : 263EXIF Metadata provided by EXIF.tools