Clipcomm EDR-AP Bluetooth Access Point User Manual
Clipcomm, Inc. Bluetooth Access Point Users Manual
Clipcomm >
Users Manual
■ Table of Contents 1. EDR-AP KEY FEATURES 2. PART CHECKLIST 3. PRODUCT DESCRIPTION 4. SPECIFICATION 5. CONTROLS AND FUNCTIONS [BUTTON/LED/REAR PANEL] 6. EDR-AP INSTALLATION 7. CAUTION 8. ETHERNET NETWORK CONNECTION ■ EDREDR-AP Key Features EDR-AP supports Bluetooth PAN / DUN / OPP Gateway. EDR-AP provides a built-in web server for convenient configuration. EDR-AP support private leased lines, ADSL/VDSL modems using PPPoE and cable modems (DHCP). ■ Part Checklist Please check and make sure that you have the following package contents. Item Q’ty Use EDR-AP Body EDR-AP main body User Manual User guide that explains implementation examples Antenna Bluetooth Antenna Power Adaptor EDR-AP power supply device LAN Cable(1.5m) Cable that connects EDR-AP and Internet Modem features, functions and ■ Product Description Please check and make sure that you have all the following package contents. ■ Specification Name Description Output Power 15 ~ 20 dBm Rx Sensitivity 85 dBm Channel 79 CH Antenna 2.4GHz Band 1/2λSleeve Dipole Antenna Frequency 2402 ~ 2480 MHz Modulation FSK, QPSK Adaptor 5V 1A Max Current 560mA Operating Temperature -20℃~55℃ ■ Controls and Functions ▌ Button Name Button Description If you press any two buttons on the unit, the LED (Green) blinks and EDR-AP goes to discoverable and pairable mode. ▌LEDs Name Color Status ON STATUS WAN Green Green BLINK Description Power is ON and Bluetooth is normal state mode Other device is connected and new device is under pairable mode OFF Power is OFF or Bluetooth is abnormal state mode ON TCP/IP communication is able mode BLINK OFF TCP/IP communication is disable mode No connection with the Ethernet * When EDR-AP restarts, every LED blinks several times ▌ Rear Panel (From the left to the right side) Name Description RESET Press this button for more than three seconds to restore the original factory default setting of EDR-AP (Reboot: press between 1~3 seconds) 5V1A WAN Connect the Power Adaptor Connect to private leased line, ADSL/VDSL modem, cable model using LAN cable (UTP Cable) ■ EDREDR-AP Installation Please check the port location of the rear panel and then follow the steps below to install the BS-P100 properly. ▌ Ethernet Network Connection Let’s check the network cable connection to use the internet service. Modem ① Pull out the cable from the Ethernet (LAN) port of modem and connect it to the WAN port at the EDR-AP’s rear panel. ② Connect the power adaptor to the “POWER” port at the EDR-AP rear panel. ③ Connect antenna provided to antenna connecting jack at the side of body. When you connect antenna, twist it on carefully and lastly push it strongly. 10 ■ CAUTION Use only the power adaptor supplied. Using other power adaptors may cause the voice quality to deteriorate and malfunction. Install EDR-AP far from wireless LAN/microwave about 1m. If installed close may cause jamming. Use only the antenna provided. The data of this device could be lost When the static electricity occurs in antenna portion 11 ■ Configuration using Web Interface You can use Web Interface with web browser in order to set the EDR-AP configuration. You can access the Web Interface by IP address or Bluetooth connection (PAN). For the access by Bluetooth connection, connect with PAN of EDR-AP and access with Gateway address assigned from the PC. ▌ Checking device’ device’s IP address In case of you don’t know the IP address, you can check the current EDR-AP IP address by configuring IP address of user’s PC. ① Click [Start] from the bottom menu bar, then choose [Settings]. ② Select [Control Panel] to view a new window, and then choose [Network connections]. ③ Right click on [Local Area Connection]. If there are more than one Local Area Connections, choose the one that is currently in use. ④ Choose [Properties] when a new window appears. ⑤ Click [IP Address] tab and then check the [Obtain an IP address automatically] box. If the box is already checked, you don’t need to change anything. ⑥ Click [Ok]. You don’t need to restart your computer in Windows XP. 12 Access to the Web Page: http://EDR EDRor http://default default Gateway’ EDR-AP’ AP’s Address:1001/index.html Address Gateway’s Address:1001/index.html Address You can set the functions below through Web Page. Name Detailed Name System Status System Information Technical Specification Network Bluetooth Configuration System Restart Description You can check the status of EDR-AP You can check the information about firmware, software, hardware of EDRAP You can configure the network environment for the internet use. (Choose the network among Static IP, DHCP, ADSL(PPPoE)) You can set the environment for the Bluetooth use You can configure the Device Name, Security Level, Pin Code, Select Power Class Radius You can configure the Radius authentication method and information SNMP You can configure the information for the interoperate with SNMP server System Mgmt You can configure the ID, Password of the EDR-AP Factory Reset System reset by factory value Restart EDR-AP 13 14 ▌ Network Configuration ① Select [Configuration], and then choose [Network] to enter the network configuration page. ② Now select and set the appropriate IP configuration parameters that match your network environment from below. (a) Static IP i. Select [Static IP]. ii. Enter the IP, gateway, network mask and DNS address for EDR-AP. (b) DHCP(Dynamic IP) or Cable modem i. Select [DHCP]. (c) ADSL(PPPoE) i. Select [ADSL]. ii. Enter ADSL ID and the password. 15 ▌ Bluetooth Configuration ① Select [Configuration], and then choose [Bluetooth] to enter the network configuration page. ② When the pop up window requesting ID and Password, type USER ID: admin, Password: 0000. Title Device Name Description Means the name of the device. Choose the “User Defined” and type the name you wish. Default Value Use Default Set the Security Level. Security Configuration Level 1 : Security Code(Pin Code) Is not requested. Level 3 Level 3 : Security Code(Pin Code) Is requested. Device Configuration Radio Power Class Type the Pin Code of EDR-AP. 000000 Select the electric wave of EDR-AP. Class 1 is the strongest electric wave. Class 1 16 ▌ RADIUS ① Select [Configuration], and then choose [RADIUS] to enter the network configuration page. Title Retransmission Timeout(sec) Authentication Server Authentication Password Authentication Port Number Description Define the number of re-transmission times in case of data failures when interoperate with Radius server. Set the time interval for Retransmission. Default value 5 sec Set the domain or IP address of Radius Server. Set the Password to receive the authentication from the Radius Server. Set the Port Number of Radius Server. 1812 17 ▌ SNMP ① Select [Configuration], and then choose [SNMP] to enter the network configuration page. Title SNMP activation SNMP Accessibility SNMP GET/SET Server Setting SNMP Community Setting Description Activate the SNMP function. Check the weather or not to be accessed to the SNMP Server. Default Value enable Use Set the domain or IP address of SNMP Server. RD : Public Set the authority for Read/Write of SNMP Server interoperate. WR : private 18 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. ▌ NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following ▌ Measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. 19 ▌ ATTENTION(FCC): This appliance and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. A minimum separation distance of 20 cm must be maintained between the antenna and the person for this appliance to satisfy the RF exposure requirements. 20 21
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No XMP Toolkit : 3.1-702 Create Date : 2007:01:23 09:57:02Z Creator Tool : Pscript.dll Version 5.0 Modify Date : 2007:01:23 18:09:06+09:00 Metadata Date : 2007:01:23 18:09:06+09:00 Format : application/pdf Creator : kimhansung Title : Microsoft Word - ANYCOM-EDR-AP_ENG_20061110 _4_.doc Producer : AFPL Ghostscript 8.50 Document ID : uuid:7d9bab59-d9d7-46e5-b73d-7a70baaaeec5 Instance ID : uuid:e5c2fd95-5935-4bd1-830e-c8cc575dd92f Page Count : 21 Author : kimhansungEXIF Metadata provided by EXIF.tools