CoAsia Microelectronics 5096-SAT WearSmith ALCOHOL BREATH TESTER User Manual WearSmith W 6826 ai

CoAsia Microelectronics Corp. WearSmith ALCOHOL BREATH TESTER WearSmith W 6826 ai

User Manual

Download: CoAsia Microelectronics 5096-SAT WearSmith ALCOHOL BREATH TESTER User Manual WearSmith                     W 6826 ai
Mirror Download [FCC.gov]CoAsia Microelectronics 5096-SAT WearSmith ALCOHOL BREATH TESTER User Manual WearSmith                     W 6826 ai
Document ID3119552
Application IDygp/OrwN3uN6zLZ4rGLIfg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize35.98kB (449780 bits)
Date Submitted2016-09-01 00:00:00
Date Available2016-09-01 00:00:00
Creation Date2016-08-30 11:00:43
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2016-08-30 11:00:43
Document TitleWearSmith_說明書-W_6826.ai
Document CreatorPScript5.dll Version 5.2.2
Document Author: magic_mvl

折線
Front
Size 76x76mm
Front
Components
Diagram
Back
Digital LED Display
Power Bottom
Apply a small amount of pressure on the
indention of the battery compartment cover
located on the rear of the unit and open and
away from the unit simultaneously to release
the cover. See the following diagram.
Battery
Battery Cover
Contents
Alcohol Breath Tester ( x 1 ) , Mouthpieces( x 1 ) , CR2032 Battery ( x1 ) ,
Silicon Rubber Ring ( x1 ) , Charm ( x 1 ) and User Manual ( x1)
Please be informed. The sensor warm-up
process will take around 5 min after first
insertion of the coin battery.
User Instruction Manual
Introduction
There are different types of Alcohol Breath Tester available. You can get simple devices meant
for home use and professional devices like those used by police for suspected drunk drivers.
WearSmith Alcohol Breath Tester is designed for your Personal use , it is a part of accessory in
your modern life. It is an easies way to know your breath alcohol concentration in a short time.
WearSmith Smartphone application can guide you to take an accurate measurement and
analyze your recovery time to zero by linking to the tester via Bluetooth Smart Technology .
You can also use it standalone, and it will show the result on the OLED display.
IMPORTANT
Please gargle with water before test. This can avoid heavy alcohol concentration remaining
in your mouth injures the electrochemical sensor.
Inlets
To avoid alcohol remains in mouthpiece, remember to wash mouthpiece frequently or blow
more fresh-air to clean it whenever you get non-zero result after fresh-air blowing.
Battery Socket
Mouthpiece
Unlick Batter cover to open
Test subjects should wait 20 minutes after eating, drinking, or smoking before blowing into
the WearSmith.
ONE year LIMITED Warranty
The WearSmith Alcohol Breath Tester provide the product to be free from defects in
workmanship or materials which also excluding calibration Under normal use for 12 months
from the date to purchase.
The WearSmith Alcohol Breath Tester obligation under this warranty is limited to replacing,
Adjusting or repairing the unit if returned along with proof of purchase.
This product is for personal use, is not recommended to share with others.
Due to personal health and hygiene issues, after use do not accept returns.
The Warranty is void if the unit has been tampered with Or maliciously damaged.
Warnings
Do not blow smoke, saliva or other contaminants into mouthpiece as this may damage the
sensor.
Product Maintenance
Clean the Mouthpiece
Cleaning is a normal part of owning and operating a professional level of Alcohol breath
tester . WearSmith recommends that you cleaning your mouthpiece at least once a week,
depending on the performance you observe and require. If the product is used every day, it
may need to be clean the mouthpiece more frequently.
DO NOT USE THIS DEVICE AS A TOOL TO DETERMINE WHETHER YOU OR ANYONE ELSE
SHOULD OPERATE ANY MOTOR VEHICLE OR MACHINERY.
Outlets
Accessory hole
Q : How to get a correct test value?
A : Check following tips :
- Please gargle with water before test.
- Test subjects should wait 20 minutes after eating, drinking, or smoking before
blowing into the WearSmith. When testing, continuously blow for 5 sec without
interruption.
- Blowing strength can be referred to APP pressure bar ( if connected with handset
APP ) for blow-learning.
- Whaen blowing, your lips need close to the mouthpieces.
Q : Why it show WAIT for a long time?
A : WAIT means device sensor is calibrating itself to avoid heavy alcohol concentration
remaining in your mouth to injure the electrochemical sensor.
There are two situations to see WAIT during operation :
- Insert new battery and power-on first time.
- Once device reports heavy alcohol concentration.
Q : Can I shorten the WAIT time?
A : In case the WAIT is caused by heavy alcohol concentration, you can remove the
mouthpiece and blow with fresh air. It can let the alcohol evaporate and sensor can
recover faster.
DO NOT DRINK AND DRIVE. ALWAYS HAVE A DESIGNATED DRIVER WHEN YOU DRINK
ALCOHOL.
Silicon Ring
Q&A
5096-SAT
WearSmith - Smart Alcohol Tester (BT)
Dimension
38 x 38 x 15 mm
Weight
19.91 g
NCC Warning Statement
Sensor
Electrochemical Fuel Cell
Can be set to following unit by Smartphone
- Breath Alcohol Content in mg/L
- Conver Blood Alcohol Content in %
- Conver Blood Alcohol Content in ‰
本產品符合低低功率電波輻射性電機管理辦法
Unit of Measurement
Measurement Range
0 to 1.5 mg/L
Operation temperature range
5 to 40 °C
Operation Humidity Range
0 to 100% RH non-condensing
Battery
DC 3V, Type CR2032 Lithium battery
Battery Life
Up to 1,000 tests, standby time up to 3 months
Display
Monochrome OLED graphics display
Communication
Bluetooth 4.0 Low Energy (Bluetooth Smart)
Free APP available for iPhone iOS9 and above,
Android 5.0 and above; Android Phone BLE
performance depends on Smartphone Types
1 year limited warranty
Due to pwesonal health and hygiene issues, after use
do not accept returns.
Smartphone APP
Warranty
WWW.AIR-MENTOR.COM
第十二條 經型式認證合格之低功率射頻電機,
非經許可,公司、商號或使用者均不得擅自變更頻
率、加大功率或變更原設計之特性及功能。
AIR MENTOR Technology by
CoAsia Microelectronics Corp.
©2016 All Right Reserved.
Design and Made In Taiwan
Battery Caution:
- Battery may explode or leak causing personal injury, if inserted incorrect type, short-circuited or disposed of in fire.
- Small-sized batteries can easily be swallowed. They must be kept out of the reach of small children.
- Dispose of used batteries according to the instructions.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference and (2) this device must accept any interference received, including interference that
may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.
CCAM16LP1190T2
FCC RF Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must
follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or
operating in conjunction with any other antenna or transmitter.
Back
Mobile App
In order to use WearSmith , you will need to download the WearSmith App for your
Smartphone.
Once you have done this, open the app, pair your device with your smartphone and you are
Ready to start using WearSmith .
How to use
Battery is installed
WearSmith
Screen Flow
FW version
Wait sensor warm up
STEP. 1
Check the Mouthpiece In slot.
Battery
Ready for testing
Setup Process
1. Download the WearSmtih App from the App store or Google play.
2. Go to Settings on your mobile device and make sure Bluetooth is switched on.
Pairing takes place within the WearSmith App.
3. Press the Power Button on your WearSmith Alcohol Breath Tester, then release, powering
it on and allowing it be found. No cords or adapters are needed. Open the app
from the home screen and press the “Connect WearSmith ” button.
When the screen remains the
display .
, press the “ power “Button again until “ wait “
STEP. 4
When the screen on your device reads
for 5 seconds until all the arrows are illuminated.
Sensor need release to 100%
Wait for creating an air current
Remove MYLAR for start device
blow into the mouthpiece
Menu
Starting
blow into
STEP.7
STEP. 3
Error Message 1.
The user had a short exhale time during the test, which likely means the user did not
exhale STEADILY AND CONTINUOUSLY FOR AT LEAST 5 SECONDS. Repeat steps 1 – 5
above to perform another test.
Calculator for
Drinking Capability
Blow failed,
please re-test
None Value
Analysis of
breath alcohol
concentration
STEP. 5
Testing air
The digit
sample.
Analysis of concentration
will be shown on the display as the device analyzes the
Weak
Strong
Save the data
STEP. 2
None value icon
Acceptable range icon
Warning range icon
Harmful to health icon
Error Message 2.
The unit detected a very high alcohol concentration (above 1.50mg/L).
STEP. 6
Press the "POWER" button once,
if sensor needs to be warm-up first, the screen will show "Wait" process. And after
warm-up ready, directly go to STEP.3.
When analysis is complete, the test result will be displayed. Once your WearSmith has analyzed
the sample, it will communicate the reading to your mobile device and the WearSmith value
will display. The result will be shown for about 20seconds then the unit will shut itself off
automatically. The Unit of measurement can be optional selecting for %, mg/L , ‰ on user
smartphone.
Low battery icon
FW upgrade ready icon
Example :
Breath Alcohol Content in mg/L Blood Alcohol Content in %
Message Alert
Above 1.50mg/L
Personal Profile
Over testing range 1.50mg/L
STEP. 8
Blood Alcohol Content in ‰
WearSmith will turn itself off by a default time out 20 seconds if disconnection. When it
connects to Smartphone, it will wait for 30 seconds then turn off.
Alcohol Concetration
The average position of blowing
pressure reference
Last measurement
Test Result
Edit your profile to
calculate body
recovery time
第十四條 低功率射頻電機之使用不得影響飛航安
全及干擾合法通信;經發現有干擾現象時,應改善
至無干擾時方得繼續使用。前項合法通信,指依電
信法規定作業之無線電通信。低功率射頻電機須忍
受合法通信或工業、科學及醫療用電波輻射性電機
設備之干擾。
You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could
void your authority to operate the equipment.
FCC ID : 2AEGI-5096-SAT
Inserting the Mouthpiece
Do not cover the holes while testing and
Do not test without mouthpiece.
For more information, please visit
Product Name
Body recovery time
to zero

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : magic_mvl
Create Date                     : 2016:08:30 11:00:43+08:00
Modify Date                     : 2016:08:30 11:00:43+08:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Format                          : application/pdf
Title                           : WearSmith_說明書-W_6826.ai
Creator                         : magic_mvl
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 11.0 (Windows)
Document ID                     : uuid:96ccf07c-3ae6-4960-b144-bdae77880689
Instance ID                     : uuid:9ed3e741-797f-427c-96c8-202f5e449d8b
Page Count                      : 1
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AEGI-5096-SAT

Navigation menu