CoAsia Microelectronics 5096-SAT WearSmith ALCOHOL BREATH TESTER User Manual WearSmith W 6826 ai
CoAsia Microelectronics Corp. WearSmith ALCOHOL BREATH TESTER WearSmith W 6826 ai
User Manual
折線 Front Size 76x76mm Front Components Diagram Back Digital LED Display Power Bottom Apply a small amount of pressure on the indention of the battery compartment cover located on the rear of the unit and open and away from the unit simultaneously to release the cover. See the following diagram. Battery Battery Cover Contents Alcohol Breath Tester ( x 1 ) , Mouthpieces( x 1 ) , CR2032 Battery ( x1 ) , Silicon Rubber Ring ( x1 ) , Charm ( x 1 ) and User Manual ( x1) Please be informed. The sensor warm-up process will take around 5 min after first insertion of the coin battery. User Instruction Manual Introduction There are different types of Alcohol Breath Tester available. You can get simple devices meant for home use and professional devices like those used by police for suspected drunk drivers. WearSmith Alcohol Breath Tester is designed for your Personal use , it is a part of accessory in your modern life. It is an easies way to know your breath alcohol concentration in a short time. WearSmith Smartphone application can guide you to take an accurate measurement and analyze your recovery time to zero by linking to the tester via Bluetooth Smart Technology . You can also use it standalone, and it will show the result on the OLED display. IMPORTANT Please gargle with water before test. This can avoid heavy alcohol concentration remaining in your mouth injures the electrochemical sensor. Inlets To avoid alcohol remains in mouthpiece, remember to wash mouthpiece frequently or blow more fresh-air to clean it whenever you get non-zero result after fresh-air blowing. Battery Socket Mouthpiece Unlick Batter cover to open Test subjects should wait 20 minutes after eating, drinking, or smoking before blowing into the WearSmith. ONE year LIMITED Warranty The WearSmith Alcohol Breath Tester provide the product to be free from defects in workmanship or materials which also excluding calibration Under normal use for 12 months from the date to purchase. The WearSmith Alcohol Breath Tester obligation under this warranty is limited to replacing, Adjusting or repairing the unit if returned along with proof of purchase. This product is for personal use, is not recommended to share with others. Due to personal health and hygiene issues, after use do not accept returns. The Warranty is void if the unit has been tampered with Or maliciously damaged. Warnings Do not blow smoke, saliva or other contaminants into mouthpiece as this may damage the sensor. Product Maintenance Clean the Mouthpiece Cleaning is a normal part of owning and operating a professional level of Alcohol breath tester . WearSmith recommends that you cleaning your mouthpiece at least once a week, depending on the performance you observe and require. If the product is used every day, it may need to be clean the mouthpiece more frequently. DO NOT USE THIS DEVICE AS A TOOL TO DETERMINE WHETHER YOU OR ANYONE ELSE SHOULD OPERATE ANY MOTOR VEHICLE OR MACHINERY. Outlets Accessory hole Q : How to get a correct test value? A : Check following tips : - Please gargle with water before test. - Test subjects should wait 20 minutes after eating, drinking, or smoking before blowing into the WearSmith. When testing, continuously blow for 5 sec without interruption. - Blowing strength can be referred to APP pressure bar ( if connected with handset APP ) for blow-learning. - Whaen blowing, your lips need close to the mouthpieces. Q : Why it show WAIT for a long time? A : WAIT means device sensor is calibrating itself to avoid heavy alcohol concentration remaining in your mouth to injure the electrochemical sensor. There are two situations to see WAIT during operation : - Insert new battery and power-on first time. - Once device reports heavy alcohol concentration. Q : Can I shorten the WAIT time? A : In case the WAIT is caused by heavy alcohol concentration, you can remove the mouthpiece and blow with fresh air. It can let the alcohol evaporate and sensor can recover faster. DO NOT DRINK AND DRIVE. ALWAYS HAVE A DESIGNATED DRIVER WHEN YOU DRINK ALCOHOL. Silicon Ring Q&A 5096-SAT WearSmith - Smart Alcohol Tester (BT) Dimension 38 x 38 x 15 mm Weight 19.91 g NCC Warning Statement Sensor Electrochemical Fuel Cell Can be set to following unit by Smartphone - Breath Alcohol Content in mg/L - Conver Blood Alcohol Content in % - Conver Blood Alcohol Content in ‰ 本產品符合低低功率電波輻射性電機管理辦法 Unit of Measurement Measurement Range 0 to 1.5 mg/L Operation temperature range 5 to 40 °C Operation Humidity Range 0 to 100% RH non-condensing Battery DC 3V, Type CR2032 Lithium battery Battery Life Up to 1,000 tests, standby time up to 3 months Display Monochrome OLED graphics display Communication Bluetooth 4.0 Low Energy (Bluetooth Smart) Free APP available for iPhone iOS9 and above, Android 5.0 and above; Android Phone BLE performance depends on Smartphone Types 1 year limited warranty Due to pwesonal health and hygiene issues, after use do not accept returns. Smartphone APP Warranty WWW.AIR-MENTOR.COM 第十二條 經型式認證合格之低功率射頻電機, 非經許可,公司、商號或使用者均不得擅自變更頻 率、加大功率或變更原設計之特性及功能。 AIR MENTOR Technology by CoAsia Microelectronics Corp. ©2016 All Right Reserved. Design and Made In Taiwan Battery Caution: - Battery may explode or leak causing personal injury, if inserted incorrect type, short-circuited or disposed of in fire. - Small-sized batteries can easily be swallowed. They must be kept out of the reach of small children. - Dispose of used batteries according to the instructions. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. CCAM16LP1190T2 FCC RF Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Back Mobile App In order to use WearSmith , you will need to download the WearSmith App for your Smartphone. Once you have done this, open the app, pair your device with your smartphone and you are Ready to start using WearSmith . How to use Battery is installed WearSmith Screen Flow FW version Wait sensor warm up STEP. 1 Check the Mouthpiece In slot. Battery Ready for testing Setup Process 1. Download the WearSmtih App from the App store or Google play. 2. Go to Settings on your mobile device and make sure Bluetooth is switched on. Pairing takes place within the WearSmith App. 3. Press the Power Button on your WearSmith Alcohol Breath Tester, then release, powering it on and allowing it be found. No cords or adapters are needed. Open the app from the home screen and press the “Connect WearSmith ” button. When the screen remains the display . , press the “ power “Button again until “ wait “ STEP. 4 When the screen on your device reads for 5 seconds until all the arrows are illuminated. Sensor need release to 100% Wait for creating an air current Remove MYLAR for start device blow into the mouthpiece Menu Starting blow into STEP.7 STEP. 3 Error Message 1. The user had a short exhale time during the test, which likely means the user did not exhale STEADILY AND CONTINUOUSLY FOR AT LEAST 5 SECONDS. Repeat steps 1 – 5 above to perform another test. Calculator for Drinking Capability Blow failed, please re-test None Value Analysis of breath alcohol concentration STEP. 5 Testing air The digit sample. Analysis of concentration will be shown on the display as the device analyzes the Weak Strong Save the data STEP. 2 None value icon Acceptable range icon Warning range icon Harmful to health icon Error Message 2. The unit detected a very high alcohol concentration (above 1.50mg/L). STEP. 6 Press the "POWER" button once, if sensor needs to be warm-up first, the screen will show "Wait" process. And after warm-up ready, directly go to STEP.3. When analysis is complete, the test result will be displayed. Once your WearSmith has analyzed the sample, it will communicate the reading to your mobile device and the WearSmith value will display. The result will be shown for about 20seconds then the unit will shut itself off automatically. The Unit of measurement can be optional selecting for %, mg/L , ‰ on user smartphone. Low battery icon FW upgrade ready icon Example : Breath Alcohol Content in mg/L Blood Alcohol Content in % Message Alert Above 1.50mg/L Personal Profile Over testing range 1.50mg/L STEP. 8 Blood Alcohol Content in ‰ WearSmith will turn itself off by a default time out 20 seconds if disconnection. When it connects to Smartphone, it will wait for 30 seconds then turn off. Alcohol Concetration The average position of blowing pressure reference Last measurement Test Result Edit your profile to calculate body recovery time 第十四條 低功率射頻電機之使用不得影響飛航安 全及干擾合法通信;經發現有干擾現象時,應改善 至無干擾時方得繼續使用。前項合法通信,指依電 信法規定作業之無線電通信。低功率射頻電機須忍 受合法通信或工業、科學及醫療用電波輻射性電機 設備之干擾。 You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. FCC ID : 2AEGI-5096-SAT Inserting the Mouthpiece Do not cover the holes while testing and Do not test without mouthpiece. For more information, please visit Product Name Body recovery time to zero
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : magic_mvl Create Date : 2016:08:30 11:00:43+08:00 Modify Date : 2016:08:30 11:00:43+08:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Title : WearSmith_說明書-W_6826.ai Creator : magic_mvl Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 11.0 (Windows) Document ID : uuid:96ccf07c-3ae6-4960-b144-bdae77880689 Instance ID : uuid:9ed3e741-797f-427c-96c8-202f5e449d8b Page Count : 1EXIF Metadata provided by EXIF.tools