Compal Electronics TP00062AWD Digitizer I/O Device User Manual RF module manual

Compal Electronics Inc Digitizer I/O Device RF module manual

Contents

RF module manual

Wacom DigitizerWacom Digitizer Implementation GuideImplementation GuideComponent Business Division Wacom Co., Ltd. 1 • 30.10.2007 • Wacom Confidential
Contents1. Principle of Wacom EMR2. General Specification3. Structure4. Digitizer Lineup5. Display Lineup6. Customizing Digitizer7. System Designing (EM noise)8. System Designing2 (metal parts)9. System Calibration10. Driver2 • 30.10.2007 • Wacom Confidential
1. Principle of Wacom EMR Receiving and transmitting coil in stylusPenY axis XaxisggyAntenna coil Sensor BoardX axis Coil switchingtransmit/receiveReceiverVHigh frequency Receiversource Signal  strength3 • 30.10.2007 • Wacom Confidential
2. General SpecificationWDiitiUitTechnology EMR (Electro-Magnetic Resonance)Wacom Digitizer UnitActive Area 263.12 * 165.2 mm for SU5E-12W16AS-00XResolution 0.01mm (2540 ppi)Coordinate Accuracy±0 4mm (see Note 1 and 2)Coordinate Accuracy±0.4mm (see Note 1 and 2)Coordinate Deviation When Tilting Pen ±3mm (tilted ±50º from vertical) (see Note 3)Detectable Pen tilt Up to 50°from verticalpDetectable Height 4 to 14mm above the Sensor Board (see Note 1)Position Report Rate 133 pps Pressure Resolution 256 levels @ full scalePower Consumption 35mA (max.70mA) @133ppsNote 1: The digitizer sensor unit and pen only, at ordinary temperature.Note 2: The pen held vertically at 7mm high from sensor board.Nt 3Th hldi th t fth ti4 • 30.10.2007 • Wacom ConfidentialNote 3: The pen held in the center of the active area.
3-1. StructureEMR digitizer be inserted under the LCD5 • 30.10.2007 • Wacom Confidential
3-2. StructureEMR digitizer be inserted under the LCD6 • 30.10.2007 • Wacom Confidential
4-1. Digitizer LineupSensor : G4    ・・・ glass epoxy sensorG4.5 ・・・ glass epoxy sensor G5    ・・・ PET film or FPC (Polyimide)G4/G4.5 G57 • 30.10.2007 • Wacom Confidential
4-2. Digitizer LineupG5 sensor8 • 30.10.2007 • Wacom Confidential
4-3. Digitizer Line upTechnology : 1. EMR only  y2. Resistive-DualTouch・・・ sensor + Resistive Touch screen interface3. Capacitive-DualTouch・・・ sensor + Capacitive Touch screen interfaceEMR only R-Dual C-Dual9 • 30.10.2007 • Wacom Confidential
4-4. Digitizer LineupInterface : UART, USBSi l i t (UART)Signal assignment (UART)Signal assignment (USB)10 • 30.10.2007 • Wacom Confidential
4-5. Digitizer Lineup11 • 30.10.2007 • Wacom Confidential
5. Display LineupLCD---Kangaroo type                                ・E-ink display12 • 30.10.2007 • Wacom Confidential
6-1. Customizing DigitizerCondition for digitizer customization1. Minimum Volume: 30K/ yeary2. There will be NRE and Tooling Cost13 • 30.10.2007 • Wacom Confidential
6-2. Customizing DigitizerSensor Board Design 1. Must be square shaperectangle square round heart2. Must be flat3Nonacti e area m st be at least 4mm at each sideOK NG3.Non-active area must be at least 4mm at each sidetliat least 4mmoutlineactive area digitizer14 • 30.10.2007 • Wacom Confidential
6-3. Customizing DigitizerSensor Board Design (continued)4. Digitizer active area needs at lease 1mm buffer from LCD active garea at each sideLCD outline1mm1mm1mmLCD outlineLCD active areadigitizer outline1mmdigitizer outlinedigitizer active area15 • 30.10.2007 • Wacom Confidential
6-4. Customizing Digitizer Baby Board DesignOnly standard design available. ygInterface connectorC t di iti DF19L14P1H (HIROSE) i l tConnector on digitizer: DF19L-14P-1H (HIROSE) or equivalentCounterpart connector: DF19-14S-1S, DF19G-14S-1C (HIROSE) or equivalent16 • 30.10.2007 • Wacom Confidential
6-5. Customizing Digitizer Dl tShdlDevelopment ScheduleNo. Step Lead Time1Cfi t di i t1Confirm custom design requirement2Release of tentative shipping specification At the same time as ES sample shipment 3ES sample shipment810 weeks3ES sample shipment                                              *handmade sample with default firmware8-10 weeks4Customer confirmation of shipping specification5System  calibration 2 weeks6Customer approval of ES sample7CS l hi t810 k7CS sample shipment                                                *tooled sample with final calibrated firmware8-10 weeks8Release of final shipping specification At the same time as CS sample shipment 8Customer approval of MP                                    (including shipping specification, FW and CS sample)9MP shipment 8-10 weeks17 • 30.10.2007 • Wacom ConfidentialNote: Lead time stated here is only reference and may change depending on digitizer design. Please confirm the final development  schedule with Wacom sales.
7-1. System Designing Prevention of EM noise problemSome transformers or coils in the po er nit generates EM noiseSome transformers or coils in the power unit generates EM noise.  TopreventthisTopreventthis• Use transformers or coils that won’t allow magnetic flux leakage.• Place them underneath the shield or in a distance as much as possible from thesensor board.• Position them so that EM noise flux did not across the sensorboard.EM noise source•InverterofLCDbacklight•InverterofLCDbacklight• DC to DC converter in power circuit18 • 30.10.2007 • Wacom Confidential
7-2. System DesigningBView B-B’LCDEM Noise CountermeasureB’DigitizerInverterShieldorIMPORTANT!Digitizer is sensitive to Electromagnetic Noise.Inverter is one of the strongest EM source.Shielding the inverter with shield plate*1, would improve an affection of the EM noise from the InverterAs far as you can,pleaseSEPARATE the Digitizer Unit!19 • 30.10.2007 • Wacom Confidentialan affection of the EM noise from the Inverter.from the Inverter
7-3. System DesigningPC CaseEM Noise Countermeasure2LCDDigitizerCOILLike DC-DC ConverterIn case of PC in one body, motherboard is located right beneath the Digitizer unit. Coils in the power unit generates the EM noise and it will gpgcause of inaccuracy of the Digitizer. Shield the COIL with shield plate*1 for better Digitizer quality.20 • 30.10.2007 • Wacom Confidential
7-4. System DesigningExample of Noise Shield1Noise Source Shielded21 • 30.10.2007 • Wacom Confidential
7-5. System DesigningExample of Noise Shield2Noise Source Shielded22 • 30.10.2007 • Wacom Confidential
8-1. System Designing2Reduction of metal influenceSome metal structure reduces digitizer signal which causes coordinate error.TopreventthisTopreventthis• Do not use metal for upper case.• Contact Wacom to make Error calibrated firmware data.Metal influence source• LCD metal bezel and lamp cover• Upper case ( if it is made of metal )23 • 30.10.2007 • Wacom Confidential
8-2. System Designing2Minimize Metal influenceLCD Upper BezelUpper caseLCD Lamp coverEM signal decreaseEM signal decrease24 • 30.10.2007 • Wacom ConfidentialMetal on the digitizer will disturb the EM signal from the pen.
8-3. System Designing2Full Metal Upper CaseBad Example of Metal Parts125 • 30.10.2007 • Wacom Confidential
8-4. System Designing2Wrapped by Metal SheetBad Example of Metal Parts226 • 30.10.2007 • Wacom Confidential
9-1. System CalibrationWacom will do following evaluation in order to prevent adverse affect from EM noise and metal parts1. EM noise environment2. Coordinate stability3Coordinate accuracy3.Coordinate accuracyWacom will provide FW data and evaluation report.Calibration work will take approximately 1-2 weeks.C lib i k h i US$1 200 lib iCalibration work charge is US$1,200 per calibration.27 • 30.10.2007 • Wacom Confidential
9-2. System CalibrationEM noise environment•EM noise which mimic pen signal can cause digitizer malfunction. •Wacom will search the EM noise and measure the level•Wacom will search the EM noise and measure the level.28 • 30.10.2007 • Wacom Confidential
9-3. System CalibrationCoordinate stabilityEM noise can cause vibration of coordinate detected by digitizer (jitter). Wacom quantifies the level of jitter by take 100 coordinate data at each   spot and calculating standard deviation and max deviation from mean location.29 • 30.10.2007 • Wacom Confidential
9-4. System CalibrationC di t b f lib tiCoordinate accuracy before calibrationMetal parts or EM noise will disturb digitizer signal and can cause the deterioration of digitizer accuracy.Digitizer signal can be compensated by calibration up to certain level.Wacom measures the accuracy before and after calibration.30 • 30.10.2007 • Wacom Confidential
9-5. System CalibrationCoordinate accuracy after calibration31 • 30.10.2007 • Wacom Confidential
9-6. System CalibrationBefore sending calibration machine, please check below items.1Final design1.Final design2. Tooled product 3.All criteria for system design is followed3c te a o syste des g s o o ed4. All accessories (eg. AC adaptor) are enclosed 5. Valid OS is installed6. Wacom stylus (which pen to use with)7. Assembly drawing to show LCD and digitizer positionNote:Calibration is required for each design. Any material or design changes will need another calibration.When several LCDs are applied for one model FW needs to be32 • 30.10.2007 • Wacom ConfidentialWhen several LCDs are applied for one model, FW needs to be created for each LCD.
10. DriverDevice DriverWindows Vista, Windows XP, Windows 2000, Windows CE , SymbianSymbianNote:Note:for dual touch, standard interface is USB33 • 30.10.2007 • Wacom Confidential

Navigation menu