Compal Electronics TP00062AWD Digitizer I/O Device User Manual RF module manual
Compal Electronics Inc Digitizer I/O Device RF module manual
Contents
- 1. User manual regulatory
- 2. User manual
- 3. RF module manual
RF module manual
Wacom Digitizer Implementation Guide Component Business Division Wacom Co., Ltd. 1 • 30.10.2007 • Wacom Confidential Contents Principle of Wacom EMR 2. General Specification 3. Structure 4. Digitizer Lineup 5. Display Lineup 6. Customizing Digitizer 7. System Designing (EM noise) 8. System Designing2 (metal parts) 9. System Calibration 10. Driver 1. 2 • 30.10.2007 • Wacom Confidential 1. Principle of Wacom EMR Receiving g and transmitting g coil in stylus Y axis Pen Antenna coil X axis Sensor Board Coil switching transmit/receive High frequency source Receiver Signal strength 3 • 30.10.2007 • Wacom Confidential 2. General Specification Wacom Digitizer Di iti Unit U it Technology EMR (Electro-Magnetic Resonance) Active Area 263.12 * 165.2 mm for SU5E-12W16AS-00X Resolution 0.01mm (2540 ppi) Coordinate Accuracy ±0 4mm (see Note 1 and 2) ±0.4mm Coordinate Deviation When Tilting Pen ±3mm (tilted ±50º from vertical) (see Note 3) Detectable Pen tilt Up p to 50°from vertical Detectable Height 4 to 14mm above the Sensor Board (see Note 1) Position Report Rate 133 pps Pressure Resolution 256 levels @ full scale Power Consumption 35mA (max.70mA) @133pps Note 1: The digitizer sensor unit and pen only, at ordinary temperature. Note 2: The pen held vertically at 7mm high from sensor board. N t 3: Note 3 Th The pen h held ld iin th the center t off th the active ti area. 4 • 30.10.2007 • Wacom Confidential 3-1. Structure EMR digitizer be inserted under the LCD 5 • 30.10.2007 • Wacom Confidential 3-2. Structure EMR digitizer be inserted under the LCD 6 • 30.10.2007 • Wacom Confidential 4-1. Digitizer Lineup Sensor : G4 ・・・ glass epoxy sensor G4.5 ・・・ glass epoxy sensor G5 ・・・ PET film or FPC (Polyimide) G4/G4.5 7 • 30.10.2007 • Wacom Confidential G5 4-2. Digitizer Lineup G5 sensor 8 • 30.10.2007 • Wacom Confidential 4-3. Digitizer Line up Technology : EMR only 2. Resistive-DualTouch・・・ sensor + Resistive Touch screen interface 3. Capacitive-DualTouch・・・ sensor + Capacitive Touch screen interface 1. EMR only 9 • 30.10.2007 • Wacom Confidential R-Dual C-Dual 4-4. Digitizer Lineup Interface : UART, USB Si Signal l assignment t (UART) 10 • 30.10.2007 • Wacom Confidential Signal assignment (USB) 4-5. Digitizer Lineup 11 • 30.10.2007 • Wacom Confidential 5. Display Lineup LCD---Kangaroo type 12 • 30.10.2007 • Wacom Confidential ・E-ink display 6-1. Customizing Digitizer Condition for digitizer customization 1. Minimum Volume: 30K/ year 2. There will be NRE and Tooling Cost 13 • 30.10.2007 • Wacom Confidential 6-2. Customizing Digitizer Sensor Board Design 1. Must be square shape rectangle 2. square heart round Must be flat NG OK 3. Non acti e area m Non-active must st be at least 4mm at each side outline tli active area 14 • 30.10.2007 • Wacom Confidential digitizer at least 4mm 6-3. Customizing Digitizer Sensor Board Design (continued) 4. Digitizer active area needs at lease 1mm buffer from LCD active area at each side LCD outline 1mm 1mm 1mm LCD active area digitizer outline 1mm 15 • 30.10.2007 • Wacom Confidential digitizer active area 6-4. Customizing Digitizer Baby Board Design Only y standard design g available. Interface connector Connector t on di digitizer: iti DF19L-14P-1H DF19L 14P 1H (HIROSE) or equivalent i l t Counterpart connector: DF19-14S-1S, DF19G-14S-1C (HIROSE) or equivalent 16 • 30.10.2007 • Wacom Confidential 6-5. Customizing Digitizer Development tS Schedule h d l No. Step Lead Time C fi custom Confirm design i requirement Release of tentative shipping specification At the same time as ES sample shipment ES sample shipment 8 10 weeks 8-10 *handmade sample with default firmware Customer confirmation of shipping specification System calibration Customer approval of ES sample CS sample l shipment hi 2 weeks 8 10 weeks 8-10 *tooled sample with final calibrated firmware Release of final shipping specification Customer approval of MP At the same time as CS sample shipment (including shipping specification, FW and CS sample) MP shipment 8-10 weeks Note: Lead time stated here is only reference and may change depending on digitizer design. Please confirm the final development schedule with Wacom sales. 17 • 30.10.2007 • Wacom Confidential 7-1. System Designing Prevention of EM noise problem Some transformers or coils in the po power er unit nit generates EM noise noise. To prevent this • • • Use transformers or coils that won’t allow magnetic flux leakage. Place them underneath the shield or in a distance as much as possible from the sensor board. Position them so that EM noise flux did not across the sensor board. EM noise source • • Inverter of LCD back light DC to DC converter in power circuit 18 • 30.10.2007 • Wacom Confidential 7-2. System Designing EM Noise Countermeasure LCD View B-B’ Digitizer B’ Inverter or Digitizer is sensitive to Electromagnetic Noise. Inverter is one of the strongest EM source. Shielding the inverter with shield plate*1, would improve an affection of the EM noise from the Inverter Inverter. 19 • 30.10.2007 • Wacom Confidential Shield IMPORTANT As far as you can,please SEPARATE the Digitizer Unit from the Inverter 7-3. System Designing EM Noise Countermeasure2 PC Case COIL Like DC-DC Converter LCD Digitizer In case of PC in one body, motherboard is located right beneath the Digitizer unit. Coils in the p power unit g generates the EM noise and it will cause of inaccuracy of the Digitizer. Shield the COIL with shield plate*1 for better Digitizer quality. 20 • 30.10.2007 • Wacom Confidential 7-4. System Designing Example of Noise Shield1 Noise Source 21 • 30.10.2007 • Wacom Confidential Shielded 7-5. System Designing Example of Noise Shield2 Noise Source 22 • 30.10.2007 • Wacom Confidential Shielded 8-1. System Designing2 Reduction of metal influence Some metal structure reduces digitizer signal which causes coordinate error. To prevent this • • Do not use metal for upper case. Contact Wacom to make Error calibrated firmware data. Metal influence source • • LCD metal bezel and lamp cover Upper case ( if it is made of metal ) 23 • 30.10.2007 • Wacom Confidential 8-2. System Designing2 Minimize Metal influence LCD Upper Bezel Upper case LCD Lamp cover EM signal decrease Metal on the digitizer will disturb the EM signal from the pen. 24 • 30.10.2007 • Wacom Confidential 8-3. System Designing2 Bad Example of Metal Parts1 Full Metal Upper Case 25 • 30.10.2007 • Wacom Confidential 8-4. System Designing2 Bad Example of Metal Parts2 Wrapped by Metal Sheet 26 • 30.10.2007 • Wacom Confidential 9-1. System Calibration Wacom will do following evaluation in order to prevent adverse affect from EM noise and metal parts 1. 2. 3. EM noise environment Coordinate stability Coordinate accuracy Wacom will provide FW data and evaluation report. Calibration work will take approximately 1-2 weeks. C lib i work Calibration k charge iis US$1 US$1,200 200 per calibration. lib i 27 • 30.10.2007 • Wacom Confidential 9-2. System Calibration EM noise environment EM noise which mimic pen signal can cause digitizer malfunction. • Wacom will search the EM noise and measure the level level. • 28 • 30.10.2007 • Wacom Confidential 9-3. System Calibration Coordinate stability EM noise can cause vibration of coordinate detected by digitizer (jitter). Wacom quantifies the level of jitter by take 100 coordinate data at each spot and calculating standard deviation and max deviation from mean location. 29 • 30.10.2007 • Wacom Confidential 9-4. System Calibration C di t accuracy b Coordinate before calibration lib ti Metal parts or EM noise will disturb digitizer signal and can cause the deterioration of digitizer accuracy. Digitizer signal can be compensated by calibration up to certain level. Wacom measures the accuracy before and after calibration. 30 • 30.10.2007 • Wacom Confidential 9-5. System Calibration Coordinate accuracy after calibration 31 • 30.10.2007 • Wacom Confidential 9-6. System Calibration Before sending calibration machine, please check below items. 1. 2. 3. 4. 5. 6. 7. Final design Tooled product All c criteria te a for o syste system des design g is s followed o o ed All accessories (eg. AC adaptor) are enclosed Valid OS is installed Wacom stylus (which pen to use with) Assembly drawing to show LCD and digitizer position Note: Calibration is required for each design. Any material or design changes will need another calibration. When several LCDs are applied for one model model, FW needs to be created for each LCD. 32 • 30.10.2007 • Wacom Confidential 10. Driver Device Driver Windows Vista, Windows XP, Windows 2000, Windows CE , Symbian Note: for dual touch, standard interface is USB 33 • 30.10.2007 • Wacom Confidential
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : rong.rong Create Date : 2011:05:23 16:54:52+08:00 Modify Date : 2011:05:23 16:54:52+08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Title : Microsoft PowerPoint - Wacom Digitizer Design Guide 20081023.ppt [兼容模式] Creator : rong.rong Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 9.4.2 (Windows) Document ID : uuid:73db61a1-7be1-43b8-98d6-ffc9ea09b8a8 Instance ID : uuid:1e9fa342-d157-4fbb-a585-3674b7e358dd Page Count : 33EXIF Metadata provided by EXIF.tools