Diagnostic Warning Screens Screen Meaning Action required The Driver has crossed the border of the 100 air-miles radius zone. Stop the vehicle as soon as possible and take the required rest time. The 100 air-miles exemption is no longer active The Driver has crossed the border of the 150 air-miles radius zone. Stop the vehicle as soon as possible and take the required rest time. The 150 air-miles exemption is no longer active 111 The vehicle is in motion although none of the logged in the Drivers has changed their status to Driver, or the vehicle is in motion and no Drivers are logged into the system. Stop the vehicle and log in to RoadLog, or stop the vehicle and switch status to Driver. RoadLog detects that a pre-trip inspection was not performed on one or more current resources, but the vehicle is in motion, or a pre-trip inspection was performed for all resources, but at least one of those resources indicates that vehicle operation is not safe. Stop the vehicle and perform the pre-trip inspection on the resource(s) in question. Diagnostic Warning Screens Screen Meaning Action required The Self-Test Failed screen is displayed. Press the on/off button to restart the device. If the problem persists, contact Customer Assistance for support. VDO Technical Support: Tel: 855-ROADLOG or 855-762-3564 E-mail: roadlog-support@vdo.com The inserted USB device is defective and has caused the RoadLog USB port to short circuit. Remove the USB device. Press the on/off button to restart the device. If the problem persists, contact Technical Support for assistance. VDO Technical Support: Tel: 855-ROADLOG or 855-762-3564 E-mail: roadlog-support@vdo.com RoadLog cannot communicate with the vehicle, and therefore HOS calculations cannot be performed. Until the problem can be resolved, use paper logs to track Duty Status changes and activities. The internal battery has a low energy level. Replace the battery. See Battery Installation. 112 Diagnostic Warning Screens Screen Meaning Action required The vehicle started to move and RoadLog detects a USB device connected. Remove the USB device. RoadLog has detected a USB device connected while a printing request was performed. Remove the USB device and try printing again. During the printing process, a printer error was detected. Try to print again. CAUTION! Driving with a USB device in the USB port can cause damage to RoadLog and / or the USB device. If the problem persists, contact Customer Support for assistance. VDO Technical Support: Tel: 855-ROADLOG or 855-762-3564 E-mail: roadlog-support@vdo.com 113 Diagnostic Warning Screens Screen Meaning Action required Printer paper has run out. Insert a new paper roll and then tap Continue to resume printing. Tap Cancel to abort printing CAUTION! Do not touch printer head while replacing paper. It may be very hot! The printer overheated. Wait for printer to cool down. The printing resumes automatically once the temperature is in the normal range. Tap Cancel if you want to abort the current printing. During Driver log out, RoadLog detects that there is not enough available memory on the Driver Key to download data. Tap Continue to log out manually. The Driver RODS data will be stored on RoadLog. Tap Cancel to abort the log out. Download data to the Fleet Software as soon as possible to create more available memory on the Driver Key. 114 Diagnostic Warning Screens Screen Meaning Action required A transfer error has been detected during data download to the Driver Key. Tap Continue to log out manually. The Driver RODS data will be stored in RoadLog. Tap Cancel to abort the log out. RoadLog detected data conflicts between RODS data on Driver Key and the RODS data in RoadLog device. Tap Continue to continue log in. OR Tap Cancel to abort log in. Due to this conflict, merging the two sets of RODS data is not possible. As a result, RoadLog may not have enough data to calculate your HOS availability. Conflicting RODS data has been downloaded to the Driver Key. 115 OR Fix the conflicting RODS data using the RoadLog Fleet Software. Fix the conflicting RODS data using the RoadLog Fleet Software. Diagnostic Warning Screens Screen Meaning Action required The maximum number of Drivers (five) are already logged into this RoadLog device. Select a Driver from the list and tap Force Logout to log that Driver out. Tap Cancel if you don’t want to continue logging in. There is another Driver logged into RoadLog under Personal Use status. Tap Cancel if you want to cancel your log in. Select Force Logout to log out the Driver logged in under Personal Use status and continue your log in. GPS signal is unavailable. The automatic localization feature does not work. 116 Enter your location state and place manually. Diagnostic Warning Screens Screen Meaning Action required You performed an improper log out from the listed Vehicles. Tap Continue Login to continue logging in. The RoadLog calculations may be incorrect due to the missing RODS data. The RODS data found on Driver Key might be incomplete due to the improper log out. Go to the listed vehicles and recover your RODS data by inserting your Driver Key and tap Recover RODS. Tap Cancel to abort the log in. There is insufficient historical data for RODS availability calculation. If you get this message while logging in with a Driver Key, it means the RODS data found on your Key merged with the RODS data found in RoadLog, and RoadLog does not have the complete duty status history for the last 15 days. You may cancel log in and then use the RoadLog Fleet Software to reconstruct the missing parts of your RODS history on the Driver Key. You may continue the log in but RoadLog will not be able to accurately warn you when you are about to break HOS regulations. If you get this message while logging in manually, it means that your RODS data found on this RoadLog does not have the complete duty status history for the last 15 days. Vehicle is in motion and you are approaching the limit of the 150 air-miles radius zone. 117 If you go beyond this limit, the 150 air-miles exemption will automatically be disabled Diagnostic Warning Screens Screen Meaning Action required The entered date and time for a pre-trip or post-trip activity is invalid, meaning it overlaps with an already recorded log session. Tap OK and then type in a valid date for the activity you want to add. To view the available time frames for extending your on duty time, check your logs. See View Logs (Details). The inserted USB device is not a valid Driver Key. Tap OK to continue. Even thought the USB is not a valid Driver Key it can still be used for performing roadside inspections or for downloading the device related files. The inserted USB device is not a valid Fleet Key. Remove the USB device and insert a valid Fleet Key. Configuration cannot continue without having a valid Fleet key inserted in RoadLog. The tractor list may not contain the tractor created with the serial number of the RoadLog unit in this vehicle None of the downloadable files were selected and the Download button was tapped. 118 Select at least one file from the list before continuing to download. Diagnostic Warning Screens Screen 119 Meaning Action required Data download onto the USB key failed. Retry data download. The USB key memory is full. Free up some memory from the USB key by downloading to the Fleet Software, and then retry the current function. An invalid Fleet Key was inserted into the RoadLog connector. Remove the USB key and insert a valid Fleet Key to continue. Diagnostic Warning Screens Screen Meaning Action required The inserted USB device is not recognized by RoadLog. Remove the USB device and insert a valid RoadLog USB Driver or Fleet Key. The entered Driver Identification is not found in RoadLog memory. Acknowledge the message and log in with valid Driver ID. You are not able to log in to this RoadLog. During system startup, RoadLog detects that the current vehicle position is not the same position recorded when the device was switched off. 120 Driver IDs are established in the Fleet Software. Acknowledge the message. A record of the location conflict is stored in the RoadLog data. Diagnostic Warning Screens Screen Meaning Action required Driver Key memory is full. No data download can be performed on this Key. Free up some memory from the USB key by downloading to the Fleet Software, and retry download. Driver Key memory is full. Tap Continue to continue to perform a manual log out. Your RODS history will be stored in RoadLog. The available recorded RODS cannot be downloaded on the Driver Key. Tap Cancel to abort the log out. Free up some memory from the USB key by downloading to the Fleet Software, and then try to log out again. Data transfer error occurred while transferring the Driver RODS file on the Driver Key. Tap Continue to log out manually. Your RODS history will be stored in RoadLog (if there is sufficient internal memory available). Tap Cancel to abort the log out. Try to log out again. 121 Diagnostic Warning Screens Screen Meaning Action required A data transfer error occurred while performing the download to Driver Key. Remove the Driver Key, and then reinsert Driver Key and retry download. During a software update, an error was detected. Acknowledge the message. Try to install again. See Software Updates. The user attempts to perform an automatic configuration, but the Company Trailer List file is either damaged or cannot be found on the Fleet Key. Automatic configuration cannot be performed. 122 Acknowledge the message. Then, use the RoadLog Fleet Software to create or fix the Company Tractor List File on the Fleet Key. When complete, reattempt automatic configuration. Diagnostic Warning Screens Screen Meaning Action required RoadLog detects no speed pulses; therefore it cannot calculate the W factor. Acknowledge the message. RoadLog does not detect the relevant messages for the chosen synchronization interface. Check which synchronization interface RoadLog is physically connected to in the Vehicle and then try to re-synchronize. The wrong interface may have been selected. Try changing the synchronization type between J1708 and J1939 or vice versa The calculated value of the W factor is beyond the valid range. Re-enter the measurement with a valid value. W Factor value must have a value of between 2,400 and 25,000 pulses per kilometer. 123 The connection between RoadLog and the Vehicle will need to be checked. Diagnostic Warning Screens Screen 124 Meaning Action required In 30 minutes, the On Duty time rule will be broken. Stop the vehicle in 30 minutes or less and take the required rest time. In 30 minutes, the On Duty time rule for this week will be broken. Stop the vehicle in 30 minutes or less and take the required rest time. In 15 minutes the On Duty time rule for this day will be broken. Stop the vehicle in 15 minutes or less and take the required rest time. Diagnostic Warning Screens Screen Meaning Action required In 15 minutes the On Duty time rule for this week will be broken. Stop the vehicle in 15 minutes or less and take the required rest time. The Driver list from Company Support Data File contained on the Fleet Key has two or more identical sets of Driver data. Use the RoadLog Fleet Software to remove the duplicate Driver from Company Support Data File. In this case, the Driver list cannot be uploaded into RoadLog. Manual Driver log in for this RoadLog is not possible unless the Driver who wants to log in manually was previously logged in to this RoadLog unit using his or her Driver Key. Company Support Data File is not found on the Fleet Key. 125 Use the RoadLog Fleet software to create the missing file on the Fleet Key. Diagnostic Warning Screens Screen Meaning Action required RoadLog has no more memory available to record the vehicle activities, data and DVIR data. Download Company Vehicle Activities Data File and Company Vehicle DVIR Data File as soon as possible to avoid overwriting recorded activities. Company Vehicle Activities Data File or Company Vehicle DVIR Data File was not downloaded for more than 28 days. Download Company Vehicle Activities Data File and Company Vehicle DVIR Data File in the next 48 hours to avoid overwriting recorded activities. Company Vehicle Activities Data File or Vehicle DVIR Data File has not been downloaded in 29 days Download Company Vehicle Activities Data File and Company Vehicle DVIR Data File in the next 24 hours to avoid overwriting recorded activities. In 24 hours, existing vehicle activities data will be overwritten if no download is performed. 126 Diagnostic Warning Screens Screen 127 Meaning Action required The maximum number of configuration sessions (100) were recorded in RoadLog memory. Download Company Configuration Session File in order to perform the next configuration. There is no more memory available in RoadLog’s internal memory to record this Driver’s activities. Download Driver RODS binary data file as soon as possible. It is safe to remove the inserted USB device. Acknowledge the message. Remove the USB drive from the USB port. Diagnostic Warning Screens Screen Meaning Action required The inserted Key contains a Software update package. Tap Install to update RoadLog Software. See Software Updates. Tap Cancel if you don’t want to perform the software update. RoadLog detects there is no USB flash drive inserted in the USB connector. Insert a USB flash drive into the connector. Data transfer is in progress. CAUTION! Do not remove the inserted USB flash drive until you are prompted to do so. Removal of the USB flash drive during data transfer might result in data loss. 128 RoadLog Files 17. RoadLog Files Data exchange between RoadLog and the Fleet Software is achieved through transfers using the Fleet Key, Driver Key or USB flash drive. Data exchanges involve uploading and downloading several different types of files, each type of file having its own purpose. There are three types of files: • Files related to the Company • Files related to Driver use • Files related to the RoadLog EOBR device Company-Related Files (Fleet Management Software Files) Company Files are files that are either used by RoadLog during company log in sessions or that contain data recorded by RoadLog during company log in. Company Identification File The Company Identification File contains the company configuration data. • The file is created during company registration and first set up. • The file is uploaded in RoadLog memory during company log in. • The file can be downloaded only on Fleet Keys belonging to the logged in company The Company Identification File contains: • Company identification. • Company address. • Time zone of the company’s home terminal. The Company Identification File name structure is: 129 RoadLog Files • When created by the RoadLog: Carrier_ CompanyID. CID • When created by RoadLogFleet: Carrier_CompanyID_ yymmddhhmmss.CID • List of the Driver/Users permitted to log in manually. • List of predefined company trailers along with their latest DVIR report. • List of predefined company annotations. • CompanyID: the USDOT number. • List of predefined Supporting Documents activities. • yymmddhhmmss: the time the file is created. • List of company Shipment Documents. Company Tractor List File The Company Support Data File name structure is: The Company Tractor List File contains the list of RoadLog devices (up to 100) installed on the fleet’s vehicles. The file is created by the RoadLog Fleet Software during company registration and first set up. The file can be updated by the RoadLog with the latest configuration upon the user’s request. The Company Tractor List File includes: • Company identification. • When created by the RoadLog: Carrier_CompanyID_ SupportData.CSD • When created by RoadLogFleet: Carrier_CompanyID_ SupportData _ yymmddhhmmss.CSD • CompanyID: the USDOT number. • yymmddhhmmss : time the file is created. • A list of the company’s tractors. Company Vehicle Activities Data File • Configuration parameters for each of the tractors. The Company Vehicle Activities Data File contains data recorded by RoadLog during company log sessions. The file is downloaded automatically onto the Driver Key upon Driver log out. The file is created by RoadLog whenever a user requests its download onto a Driver Key or Fleet Key • The last DVIR record for each of the tractors. The Company Tractor List File name structure is: • When created by RoadLog: Carrier_ CompanyID_ TractorList.CTL Company Vehicle Activities Data File includes: • Vehicle reports recorded over the previous 30 days. • When created by the RoadLog Fleet Software: Carrier_ CompanyID_TractorList_ yymmddhhmmss.CTL The Company Vehicle Activities Data File name structure is: • CompanyID: the USDOT number. • yymmddhhmmss is the time when the file is created. • Only created by the RoadLog: Carrier_CompanyID_ TractorNumber_yymmddhhmmss.CVD Company Support Data File • CompanyID: the USDOT number. The Company Support Data File contains data used by RoadLog during company log in. The file is created by the RoadLog Fleet Software during company registration and first set up. The file is uploaded in RoadLog memory during company log in. The file is updated by RoadLog whenever a user requests its download. • Yymmddhhmmss: time the file is created. The file can be downloaded only on the Fleet Key belonging to the logged in company. The Company Support Data File includes: 130 Company Vehicle DVIR Data File The Company Vehicle DVIR Data file contains DVIR data reports recorded by RoadLog during company log sessions for the last 30 days. The file is created by RoadLog whenever a user requests its download on a Driver Key or Fleet Key belonging to the logged in company.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Create Date : 2014:11:19 11:29:07+01:00 Creator : Adobe InDesign CS6 (Macintosh) Modify Date : 2014:11:19 11:29:18+01:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2014:11:19 11:29:18+01:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Format : application/pdf Document ID : uuid:aec09bdf-1bb5-4412-a3c1-8c064017bc3d Instance ID : uuid:b51413e3-7663-4db5-b7d4-f4a8715a61ea Producer : Adobe PDF Library 10.0.1 Page Count : 20EXIF Metadata provided by EXIF.tools