Contrinex RFM30HF RFID Transponder Reader User Manual Users manual 3

Contrinex AG RFID Transponder Reader Users manual 3

Users manual 3

Download: Contrinex RFM30HF RFID Transponder Reader User Manual Users manual 3
Mirror Download [FCC.gov]Contrinex RFM30HF RFID Transponder Reader User Manual Users manual 3
Document ID3852408
Application ID6TXQuFDPDQAIvVy8h2Cm7w==
Document DescriptionUsers manual 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize36.74kB (459306 bits)
Date Submitted2018-05-16 00:00:00
Date Available2018-05-17 00:00:00
Creation Date2017-12-05 17:00:42
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2017-12-05 17:00:44
Document TitleUsers manual 3
Document CreatorAdobe InDesign CC 2017 (Windows)

HF RFID SYSTEM
READ/WRITE MODULES (RWM)
RLS-1301-320
HOUSING
READ/WRITE DISTANCE
M30
62.5 mm*
ü M30 Metal threaded housing ü 2 x PNP output in SIO
ü Sensing face of PBTP
ü Insensitive to dirt
ü IO-Link V1.1
mode configurable
ü RWM reconfigurable via
a Master Tag
* Please refer to table page 8
GENERAL DATA
Carrier frequency
Compatible standard
Maximum transmission speed
Read-write distance max.
INTERFACE
13.56 MHz
ISO 15693
26.5 kbit/s
62.5 mm with RTP-0502-022
ELECTRICAL DATA
Supply voltage range (Ub)
No-load supply current (field off)
Max. current consumption (no load)
Polling current
Short-circuit protection
Voltage reversal protection
Max. output current
Data transfer rate
LED green on
LED green blinking
LED yellow on
LED yellow blinking
38 400 baud
RWM live
IO-Link communication
Transponder detected
Transponder + IO-Link
communication
IO-Link
ü
MECHANICAL DATA
11...32 VDC
20 mA
50 mA
30 mA
ü
ü
≤ 200 mA
Protection degree
Ambient temperature range TA**
Storage temperature range TS***
Sensing face material
Housing material
IP67
-25...+80 °C
-25...+80 °C
PBTP
Chrome-plated brass
Connector type
Weight (incl. nuts)
M12 4-pin
87 g
** Read/write operations possible
*** Data retention and mechanical stability limit
CONTRINEX AG Industrial Electronics
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
MOUNTING RECOMMENDATIONS
CLEARANCE
Read/write modules must not mutually influence each other. For this reason, a minimum distance of 2 x D between the devices must be observed.
sensing face
metal free zone
10 mm
support
WIRING DIAGRAM
bk
wh
bu
PIN ASSIGNMENT
PIN
SIGNAL
FUNCTION
L+
L+
C/Q1
Q2
Q2
L-
L-
C/Q1
+24 V
DO (tag presence or data comparison)
OV
SDCI/SIO (tag presence or data
comparison)
IO-LINK CHARACTERISTICS
VALUE FOR RLS-1301-320
IO-Link Protocol
COM-Mode
Min. cycle time
Process data width in
Process data width out
Profile
SIO-Mode support
Port type
Memory request for data management
Device ID
Vendor ID
1.1
COM2 (38.4 kBaud)
14.4 ms
9 bytes
10 bytes
Smart Sensor Profile
Yes
41 bytes
0xAB0300
0x0156
CONTRINEX AG Industrial Electronics
M12
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
CONFIGURATION PARAMETER (IO-LINK / SIO MODE)
Index
Sub Hex
Name
Access
Data Type
Value
Default
IDENTIFICATION
10h
11h
12h
13h
14h
15h
17h
Vendor Name
Vendor Text
Product Name
Product ID
Product Text
Serial Number
Firmware Revision
char []
char []
char []
char []
char []
char []
char []
“Contrinex“
“www.contrinex.com“
“RLS-1301-320“
“00000000“
“IO-Link RFID reader“
“00000001“
“01.09.01“
18h
Application Specific Tag
R/W
char []


READER PARAMETER PROCESS DATA
40h
01h
Operating Mode
R/W
uint8
FFh : Scan UID
00h : Scan User Data
01h : Read / Write Command
FFh
FFh
02h
Data Hold Time
R/W
uint8
FFh : No Hold Time
00h : Hold Time 100 ms
01h : Hold Time 200 ms
02h : Hold Time 500 ms
03h : Hold Time 1000 ms
04h : Hold Time 2000 ms
03h
Scan Address
R/W
uint8
Address to scan
FFh
READER PARAMETER SIO
41h
01h
C/Q1 PIN SIO Operating
Mode
R/W
uint8
FFh : Presence Transponder
00h : Compare Data
01h : No SIO
FFh
02h
C/Q1 SIO Data to compare H
R/W
uint32
Comparison value Byte 7 to 4
FFh, FFh,
FFh, FFh,
03h
C/Q1 SIO Data to compare L
R/W
uint32
Comparison value Byte 3 to 0
FFh, FFh,
FFh, FFh,
04h
SIO Compare Data Address
(C/Q1 & Q2)
R/W
uint8
Comparison address for C/Q1 and Q2 (A valid
address must be chosen)
FFh
FFh
05h
Data Hold Time Output
(C/Q1 & Q2)
R/W
uint8
FFh : No Hold Time
00h : Hold Time 100 ms
01h : Hold Time 200 ms
02h : Hold Time 500 ms
03h : Hold Time 1000 ms
04h : Hold Time 2000 ms
06h
C/Q1 PIN SIO Polarity
R/W
uint8
FFh : Output “close” if condition = true
00h : Output “open” if condition = true
FFh
FFh
07h
Q2 PIN SIO Operating Mode
R/W
uint8
FFh : Presence Transponder
00h : Compare data (C/Q1 must be also in compare data)
01h : No SIO
08h
Q2 SIO Data to compare H
R/W
uint32
Comparison value Byte 7 to 4
FFh, FFh,
FFh, FFh,
09h
Q2 SIO Data to compare L
R/W
uint32
Comparison value Byte 3 to 0
FFh, FFh,
FFh, FFh,
0Ah
Q2 PIN SIO Polarity
R/W
uint8
FFh : Output “close” if condition = true
00h : Output “open” if condition = true
FFh
CONTRINEX AG Industrial Electronics
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
PROCESS DATA REPRESENTATION
PROCESS DATA MODE SCAN UID MODE
PROCESS DATA INPUT
Bitoffset
TAG
ANT
UID 0
UID 1
UID 2
UID 3
UID 4
UID 5
UID 6
UID 7
NB TAG
TAG :
ANT :
NB TAG :
UID 0 :
UID 7 :
0 = No tag present in front of the RWM
1 = 1 tag or more present in front of the RWM
0 = RF field off
1 = RF field on
Number of tag in front of the RWM
UID LSB
UID MSB
PROCESS DATA OUTPUT
Bitoffset
N_ANT
N_ANT :
TAG NB
TAG NB :
0 = Switch on RF field
1 = Switch off RF field
Index of tag to be printed in UID area
(index from 0)
PROCESS DATA MODE SCAN USER DATA
PROCESS DATA INPUT
Bitoffset
RDY
ERR
TAG
ANT
Data 0 / Error Code
Data 1
Data 2
Data 3
Extended Data 4
Extended Data 5
Extended Data 6
Extended Data 7
EXT
RDY :
ERR :
TAG :
ANT :
EXT :
Data 0 :
Data 3 / 7 :
0 = No data available yet
1 = Memory scanned and data available
0 = Memory scanned and no error
1 = Memory scanned but error;
0 = No tag present in front of the RWM
1 = Tag present in front of the RWM
0 = RF field off
1 = RF field on
0 = 4 bytes data
1 = 8 bytes data
User data LSB / Error Code
User data MSB
PROCESS DATA OUTPUT
Bitoffset
N_ANT
CONTRINEX AG Industrial Electronics
N_ANT :
0 = Switch on RF Field
1 = Switch off RF Field
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
PROCESS DATA MODE READ/WRITE
PROCESS DATA INPUT
Bitoffset
RDY
ERR
TAG
ANT
Data 0 / Error Code
Data 1
Data 2
Data 3
Extended Data 4
Extended Data 5
Extended Data 6
Extended Data 7
EXT
RDY :
ERR :
TAG :
ANT :
EXT :
Data 0 :
Data 3 / 7 :
0 = No data available yet
1 = Command executed and data available
0 = Command executed and no error
1 = Command executed but error
0 = No tag present in front of the RWM
1 = Tag present in front of the RWM
0 = RF field off
1 = RF field on
0 = 4 bytes data
1 = 8 bytes data
Read data LSB / Error Code
Read data MSB
Error Code Definition
CommandNotSupported
FormatError
OptionNotSupported
CommandProblem
CommTagError
TagError
NoMomoryBloc
BlocProtected
= 1,
= 2,
= 3,
= 5,
= 6,
= 15,
= 16,
= 18,
PROCESS DATA OUTPUT
Bitoffset
0 START
N_ANT
CMD
ADD
Data 0
Data 1
Data 2
Data 3
Extended Data 4
Extended Data 5
Extended Data 6
Extended Data 7
EXT
START :
N_ANT :
CMD :
EXT :
ADD :
Data 0 :
Data 3 / 7 :
0 = Do not execute the command
1 = Execute the command
0 = Switch on RF Field
1 = Switch off RF Field
0 = No command
1 = Read
2 = Write
0 = 4 bytes data
1 = 8 bytes data
Block address
Write data LSB
Write data MSB
SYSTEM COMMAND (idx 02h)
Value hex
Value dec
Function
05h
80h
82h
128
130
ParamDownloadStore
Device Reset
Restore factory settings*
*always do a reset after the restore of factory settings
CONTRINEX AG Industrial Electronics
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
MASTER TAG CONFIGURATION
For the RLS-1301-320, the IO-Link mode or the SIO (standard I/O mode) can be configured via IO-Link or via a Master Tag.
For the configuration via a Master Tag, a transponder (called Master Tag) will contain all the data used for the configuration.
There is a simple procedure to configure the RWM. Once all the data are written in the Master Tag, you need to put it in front of the RWM sensing face,
to switch off the RWM power supply and to switch on again. The RWM will detect that it’s a Master Tag and read all the data and configure the outputs
accordingly.
On the Contrinex RFID product finder page (https://www.contrinex.com/product-finder/rfid/) of any ContriNET RWM USB, it is possible to download a
software to setup the Master Tag using a ContriNET RWM USB. This program is called “IO-Link Master Tag Programmer” and its it is included in the
“Softwares” zip file.
SIO MODE POSSIBILITIES
If you use the RLS-1301-320 in an SIO mode, you will have two main possibilities:
1.
Presence Transponder:
In this mode, the output will switch if a transponder is in the field of the RWM.
2.
Compare Data:
In this mode, the output will switch if the data red in the defined block memory of the transponder matches with the data stocked in the RWM.
MASTER TAG
To build a Master Tag it’s possible to use any ISO15693 chip with at least eight memory blocks with 32 bits each. Two screenshots of the “IO-Link
Master Tag Programmer” are placed below to serve as an example of one possible Master Tag configuration
Read/Write Module used
Output switch condition selection for C/Q1 (Compare data)
Compare data value (DEC) to switch output C/Q1
Output switch condition selection for Q2 (Tag presence)
Tag memory address value (DEC) where to perform the compare data operation
Timer value during which the switching state is maintained after the transponder left the
RWM detection range
Selection box for the IO-Link operation mode (Scan UID, Scan User Data and Scan Read/
Write Command)
Scan address where to read the RFID data (only available when Scan User Data mode is
selected)
When Tag Master data (SIO & IO-Link Mode) is successfully programmed in to the tag
memory, the "Program Master TAG" button turns green , otherwise it turns red
CONTRINEX AG Industrial Electronics
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
POSSIBLE COMBINATION AND TYPICAL DISTANCE - RLS-1181-320
Transponder type
Smax
S0
D0
Ø9
Ø 16
Ø 20
Ø 26
Ø 30
Ø 50
Ø 50
Ø 50
Ø 50
16
36
26
34
36
47
62.5
61
59
17
10.5
15.5
15.5
20
29.5
28.5
27.5
22
38
31
37
41
54
66
65
63
RTP-0090-020
RTP-0160-020
RTP-0201-020
RTP-0263-020
RTP-0301-020
RTP-0501-020
RTP-0502-022
RTP-0502-062
RTP-0502-082
Working area
Read/Write Module
Transponder
D0
RLLS--133011-00
S0
Smax
AVAILABLE TYPES
Part number
Part reference
Ø
Mounting
Connection
720 100 207
RLS-1301-320
M30
Non-embeddable
M12 4-pin
DISCLAIMERS
FCC information
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.
Note:This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
IC information
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence. L`exploitation est autorisée aux
deux conditions suivantes :
(1) L`appareil ne doit pas produire de brouillage, et
(2) l’utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement.
Contrinex information
Operators of the products we supply are responsible for compliance with measures for the protection of persons. The use of our equipment in applications where the safety of persons might be at risk is only authorized if the operator observes and implements separate, appropriate and necessary
measures for the protection of persons and machines. Terms of delivery and rights to change design reserved.
CONTRINEX AG Industrial Electronics
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
RLS-1301-320_171205_YAG

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c137 79.159768, 2016/08/11-13:24:42
Create Date                     : 2017:12:05 17:00:42+01:00
Metadata Date                   : 2017:12:05 17:00:44+01:00
Modify Date                     : 2017:12:05 17:00:44+01:00
Creator Tool                    : Adobe InDesign CC 2017 (Windows)
Instance ID                     : uuid:0b9963aa-3b14-458a-82f4-e9200efce52b
Original Document ID            : xmp.did:7455C9DD35D0E311B768B6FD92D29AA0
Document ID                     : xmp.id:ece43c66-da95-0c48-a5ea-25e163f27150
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:83bbc46e-c3e8-404c-81c2-237cb30db0cf
Derived From Document ID        : xmp.did:79c9baf0-8c73-e643-ae4a-8cd0c2b64941
Derived From Original Document ID: xmp.did:7455C9DD35D0E311B768B6FD92D29AA0
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2017 (Windows)
History Changed                 : /
History When                    : 2017:12:05 17:00:42+01:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 7
Creator                         : Adobe InDesign CC 2017 (Windows)
EXIF Metadata provided by EXIF.tools