Controlled Electronic Management Systems TSR618V93F Emerald Intelligent Fingerprint Terminal User Manual 15 Emerald Fingerprint Quick Guide
Controlled Electronic Management Systems Ltd Emerald Intelligent Fingerprint Terminal 15 Emerald Fingerprint Quick Guide
Users Manual
Specifications Hex security screwdriver Star head screwdriver Part TSR-QG-0072-1 Mounting the Terminal Opening the terminal 1. Set the terminal on a level surface. 2. Remove the four screws using a security hex screwdriver. 3. Remove the front part of the terminal, pivoting at the base. 4. Disconnect the ribbon cable from the I/O board. emerald TS300f -20°C to 70°C (4°F to 158F) flame-retardant polycarbonate. IP65 rated DC power (unit only) 12v nominal (10v – 14v) @500mA peak. (Typically 300 – 400mA) a Power over Ethernet 15W power to the terminal only. Lock and/or exit reader power should be supplied separately Inputs Four analogue inputs - voltage supplied Comms to exit reader RS485 serial comms using Wiegand protocol Comms to system host 10/100 Base-T TCP/IP CAT5/5e If inputs are used to trigger alarms or events in AC2000 AED they must first be configured in the AC2000 Devices application. (See AC2000 Setup Guide.) Dry contact outputs DC30V @ 5a Card Definitions Configuring Device Inputs Ensure that the appropriate card definitions for the chosen card technology are loaded on the CDC. a. If the DC supply is less than 12V @ 500mA a separate PSU is required for the lock 3a Wiring Configuration: emerald Fingerprint Reader + S610s SE + 3rd Party Read Head WIRING NOTES When using 24V power for a lock, it is imperative that the switch position is set to EXT. Setting the switch to INT will result in 24V being supplied to the terminal which may cause irreversible damage. INT 3rd Party Wiegand Head J19 EXT Removing the I/O board INT External selected EXT LOCK SENSE DRY CONTACT RELAY OUTPUTS: 0-24V DC @ 2A (EXTERNAL SUPPLY) WET CONTACT RELAY OUTPUTS: 12V DC NOW @ 1.3A (INTERNAL SUPPLY) RELAY 2 RELAY 1 EXT REQUEST TO EXIT INT S610s SE Reader 12V 0V NO C NC 0V NO C NC 0V 12V (Serial) J18 PSU 12V 2A min LK4 J10 H0 H1 GND GND J3 LK7 LK5 485B 485A 485B 485A Fail-safe lock If the terminal loses power a fail-safe lock opens allowing free access. Therefore a lock that is constantly powered, such as a maglock, must be used. J17 DOOR POS LOCK POS REX INTERLOCK 0V 1 RS485 A 1 RS485 B RS232 TX 3 RS485 A 3 RS485 B SAFETY GND OV RS232 RX 0V SOUNDER LED GREEN LED AMBER LED RED D1 D0 External Power Supply When the switch is set to EXT a separate DC12 – 24V power source must be used to provide power for any locks or other devices such as sounders attached to the output (J18). Note: Connect the PSU +ve to J18 pin C on RELAY 1. INT DOOR POSITION J1 LABEL EXT Internal Power Supply When the switch is set to INT, DC12V 650mA is provided to the lock or other devices attached to each output from the terminal’s internal power circuitry. 1. Remove the four screws and spacers using a star head screwdriver. 2. Lift the I/O board away from the back casing. 3. Drill the cable access holes using the guides on the back casing. 4. Drill the the holes on the terminal casing to match the back box fixture points. 1. Open AC2000 | Device Configuration | Devices. 2. In the left pane, expand the Controller to which the terminal is being added. 3. Right click the appropriate Device group and select Add Device. 4. In the Device Type drop down list, select the emerald model being installed (TS300). 5. In the Configuration Mode drop down list select the setting that matches your hardware setup. 6. In the Device Number drop down list select a device number. 7. Enter a unique description for the device in Device Location . 8. Enter the unique MAC Address of the device. (To display the MAC Address on the terminal select System information | Network). 9. Enter the unique IP address of the device. 10. Click Add to complete the setup. Keypad This guide contains the basic instructions for installing the emerald TS300f - Intelligent Fingerprint Terminal. Size H20 Size PZ3 Rating TM For a complete description of emerald TS300f and its features, refer to the Technical Product Specification at: http://www.cemsys.com/emerald Adding the device to AC2000 Required tools emerald TS300f Intelligent Fingerprint Terminal Quick Installation Guide Software Setup J15 J5 MAGNETIC LOCK J7 J6 J30 J10 GND 12V Fail-secure lock In fail-secure configuration, if the terminal loses power the lock remains closed. A lock that requires power to open such as a mortice lock must be used. Battery Link fitted JMP1 J11 Ethernet to Switch/Hub Ferrite - Double Loop 1. Using the drilled mounting holes, screw the back casing to the back box. 2. Screw the I/O board to the back casing, ensuring to replace the spacers. micro SD card SW2 Mount the back casing to back box 3b Wiring Configuration: emerald TS300f + DIU200 + S610s SE NOTE: On the DIU, if BGU, FIRE and TAMPER are not used the LABEL J1 (Serial) J17 DOOR POS LOCK POS REX INTERLOCK 0V 1 RS485 A 1 RS485 B RS232 TX 3 RS485 A 3 RS485 B H0 H1 GND J3 BGU COM FIRE TAMPER BUZZ – BGU COM FIRE TAMPER BUZZ – BGU COM FIRE TAMPER BUZZ – BUZZ + BUZZ + BUZZ + LK7 LK5 GND EXT J10 485B 485A DRY CONTACT RELAY OUTPUTS: 0-24V DC @ 2A (EXTERNAL SUPPLY) WET CONTACT RELAY OUTPUTS: 12V DC NOW @ 13A (INTERNAL SUPPLY) RELAY 2 RELAY 1 LK4 485B 485A SAFETY GND OV RS232 RX 0V SOUNDER LED GREEN LED AMBER LED RED D1 D0 EXT Keypad J19 INT connections on J9 must be linked out. S610s SE Reader Re-assembling the Terminal Care should be taken when re-assembling the unit. The front case should not be left hanging from the ribbon cable while attached to the back case. Ensure there is adequate network cable length to reach the connectors. 1. Connect the ribbon cable to the I/O board. J15 J5 J7 J6 INT 12V 0V NO C NC 0V NO C NC 0V 12V J18 BGU 2. Attach the front case to back case ensuring the ribbon cable folds below connector J18. FIRE REQUEST TO EXIT J30 J10 DOOR POSITION LOCK SENSE GND 12V JMP1 J11 COM RDR +12 Loop SW2 micro SD card Configuring the Network Setting the terminal IP address, SubNet mask and Gateway 1. On the terminal home screen swipe across the Date/Time area from left to right. J5 J9 BGU COM J4 J3 FIRE TAMPER BUZZ – LNK 2 LNK 3 LNK 4 LNK 5 J8 LOCK – LOCK + COM MAINS FAIL LOCKIN 12V/24V SUPPLY 12V - MAGNETIC LOCK - PSU 12V + 2A min 4. Clip the side panels on to each side of the terminal covering each of the mounting screws. Note: Power is supplied via the DIU PSU 4. Select the IP address field, enter the address and press OK. 5. Press the SubNet mask field, enter address and press OK. 6. If necessary, select the Gateway field, type the address and press OK. 7. Press Done to close the Network menu. Checking Network Status 1. Press and hold the Reader Address to show the network status indicator. Terminal has received the onboard database Terminal has received configuration settings from the CDC Terminal is connected to the RTC 2. Enter the passcode 67679999 to access the Config Menu. Note: When the terminal has received a configuration from the server the pass code changes to 67670000. 3. Press Device settings | Network 3. Screw the front casing to the back casing using the four security hex screws. TAMPER BUZZ + J1 485A 485B Ferrite Double DIU200 GPO J2 COM REX DOOR COM LOCK Terminal is connected to network via Ethernet The terminal is now connected to the AC2000 system and ready to use. Support For more information on emerald TS300f, consult the following resources. Datasheets Installation Manual User Guide http://www.cemsys.com/emerald http://www.cemsys.com/support http://www.cemsys.com/support Sales Technical Support cem.sales@tycoint.com Tel: +44 (0)28 90 456656 Safety and Regulatory Information WARNING This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Installation of this device should be performed by a qualified person in accordance to all local regulations. See the emerald Installation Manual for safety information. Copyright © 2015 Controlled Electronic Management Systems Limited. All rights reserved. No part of this publication may be produced without the written permission of CEM Systems Limited. Warnings Warning This is a class B product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Warning English Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Français Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Warning - For FCC Labelled emerald Terminals This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept an interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Installation of this device shall be performed by a qualified person in accordance to all local regulations. This system must be installed within the protected premise in accordance with the National Electrical Code (NFPA70), and the local authorities having jurisdiction. Equipment changes or modifications without the approval of the party responsible for compliance could void the user's authority to operate the equipment and could create a hazardous condition. CEM emerald Intelligent Fingerprint Terminal product codes CARD READ TECHNOLOGY TS100F TS200F TS300F FCC ID NUMBER IC ID NUMBER Mifare CSN TSR/100/115 TSR/200/115 TSR/300/115 QABTSR618V93F 12009A-TSR618V93F Picopass TSR/100/116 TSR/200/116 TSR/300/116 QABTSR618V93F 12009A-TSR618V93F CEM DESFire TSR/100/117 TSR/200/117 TSR/300/117 QABTSR618V93F 12009A-TSR618V93F iClass & iClass SE TSR/100/118 TSR/200/118 TSR/300/118 QABTSR618V93F 12009A-TSR618V93F multi smart card reader TSR/100/618 TSR/200/618 TSR/300/618 QABTSR618V93F 12009A-TSR618V93F Note: The typical read range for the integrated 13.56MHz read-head is 3 – 5cm (1.2” – 2”) Supported card technologies The emerald Intelligent Fingerprint Terminal multi smart card reader supports the following card technologies: • CEM DESFire • MIFARE CSN • iClass
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2015:09:30 15:07:58+01:00 Modify Date : 2015:09:30 15:07:58+01:00 Author : pthompson Subject : Page Count : 3 Page Layout : SinglePage Page Mode : UseNone XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:26e854fc-69d8-11e5-0000-bfd2ad630eda Producer : PDFCreator 2.1.1.0 Keywords : Creator Tool : PDFCreator 2.1.1.0 Document ID : uuid:26e854fc-69d8-11e5-0000-bfd2ad630eda Format : application/pdf Title : 15. Emerald Fingerprint Quick Guide Creator : pthompson Description :EXIF Metadata provided by EXIF.tools