Controlled Electronic Management Systems TSR618V93F Emerald Intelligent Fingerprint Terminal User Manual 15 Emerald Fingerprint Quick Guide

Controlled Electronic Management Systems Ltd Emerald Intelligent Fingerprint Terminal 15 Emerald Fingerprint Quick Guide

Users Manual

Download: Controlled Electronic Management Systems TSR618V93F Emerald Intelligent Fingerprint Terminal User Manual 15  Emerald Fingerprint Quick Guide
Mirror Download [FCC.gov]Controlled Electronic Management Systems TSR618V93F Emerald Intelligent Fingerprint Terminal User Manual 15  Emerald Fingerprint Quick Guide
Document ID2767427
Application IDLl/NNhYS3OYXJ74CZ+0ltg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize150.38kB (1879795 bits)
Date Submitted2015-09-30 00:00:00
Date Available2015-09-30 00:00:00
Creation Date2015-09-30 15:07:58
Producing SoftwarePDFCreator 2.1.1.0
Document Lastmod2015-09-30 15:07:58
Document Title15. Emerald Fingerprint Quick Guide
Document CreatorPDFCreator 2.1.1.0
Document Author: pthompson

Specifications
Hex security screwdriver
Star head screwdriver
Part
TSR-QG-0072-1
Mounting the Terminal
Opening the terminal
1. Set the terminal on a level surface.
2. Remove the four screws using
a security hex screwdriver.
3. Remove the front part of the
terminal, pivoting at the base.
4. Disconnect the ribbon cable from
the I/O board.
emerald TS300f
-20°C to 70°C (4°F to 158F) flame-retardant polycarbonate. IP65 rated
DC power (unit only)
12v nominal (10v – 14v) @500mA peak. (Typically 300 – 400mA) a
Power over Ethernet
15W power to the terminal only. Lock and/or exit reader power should be
supplied separately
Inputs
Four analogue inputs - voltage supplied
Comms to exit reader
RS485 serial comms using Wiegand protocol
Comms to system host
10/100 Base-T TCP/IP CAT5/5e
If inputs are used to trigger alarms or events in AC2000 AED they must first be configured
in the AC2000 Devices application. (See AC2000 Setup Guide.)
Dry contact outputs
DC30V @ 5a
Card Definitions
Configuring Device Inputs
Ensure that the appropriate card definitions for the chosen card technology are loaded on
the CDC.
a. If the DC supply is less than 12V @ 500mA a separate PSU is required for the lock
3a
Wiring Configuration: emerald Fingerprint Reader + S610s SE + 3rd Party Read Head
WIRING NOTES
When using 24V power for a lock, it is imperative that the
switch position is set to EXT. Setting the switch to INT
will result in 24V being supplied to the terminal which
may cause irreversible damage.
INT
3rd Party
Wiegand
Head
J19
EXT
Removing the I/O board
INT
External selected
EXT
LOCK
SENSE
DRY CONTACT RELAY OUTPUTS: 0-24V DC @ 2A (EXTERNAL SUPPLY)
WET CONTACT RELAY OUTPUTS: 12V DC NOW @ 1.3A (INTERNAL SUPPLY)
RELAY 2
RELAY 1
EXT
REQUEST
TO EXIT
INT
S610s SE Reader
12V 0V NO C NC 0V NO C NC 0V 12V
(Serial)
J18
PSU 12V
2A min
LK4
J10
H0
H1
GND
GND
J3
LK7 LK5
485B
485A
485B
485A
Fail-safe lock
If the terminal loses power a fail-safe lock opens allowing
free access. Therefore a lock that is constantly powered,
such as a maglock, must be used.
J17
DOOR POS
LOCK POS
REX
INTERLOCK
0V
1 RS485 A
1 RS485 B
RS232 TX
3 RS485 A
3 RS485 B
SAFETY GND
OV
RS232 RX
0V
SOUNDER
LED GREEN
LED AMBER
LED RED
D1
D0
External Power Supply
When the switch is set to EXT a separate DC12 – 24V
power source must be used to provide power for any locks
or other devices such as sounders attached to the
output (J18).
Note: Connect the PSU +ve to J18 pin C on RELAY 1.
INT
DOOR
POSITION
J1
LABEL
EXT
Internal Power Supply
When the switch is set to INT, DC12V 650mA is provided
to the lock or other devices attached to each output from
the terminal’s internal power circuitry.
1. Remove the four screws and spacers using a star head screwdriver.
2. Lift the I/O board away from the back casing.
3. Drill the cable access holes using the guides on the back casing.
4. Drill the the holes on the terminal casing to match the back box fixture points.
1. Open AC2000 | Device Configuration | Devices.
2. In the left pane, expand the Controller to which the terminal is being added.
3. Right click the appropriate Device group and select Add Device.
4. In the Device Type drop down list, select the emerald model being installed
(TS300).
5. In the Configuration Mode drop down list select the setting that matches
your hardware setup.
6. In the Device Number drop down list select a device number.
7. Enter a unique description for the device in Device Location .
8. Enter the unique MAC Address of the device. (To display the MAC Address
on the terminal select System information | Network).
9. Enter the unique IP address of the device.
10. Click Add to complete the setup.
Keypad
This guide contains the basic instructions for installing
the emerald TS300f - Intelligent Fingerprint Terminal.
Size H20
Size PZ3
Rating
TM
For a complete description of emerald TS300f and its
features, refer to the Technical Product Specification
at: http://www.cemsys.com/emerald
Adding the device to AC2000
Required tools
emerald TS300f
Intelligent
Fingerprint
Terminal
Quick Installation Guide
Software Setup
J15
J5
MAGNETIC
LOCK
J7
J6
J30
J10
GND 12V
Fail-secure lock
In fail-secure configuration, if the terminal loses power the
lock remains closed. A lock that requires power to open
such as a mortice lock must be used.
Battery Link fitted
JMP1
J11
Ethernet to Switch/Hub
Ferrite - Double Loop
1. Using the drilled mounting holes, screw the back casing to the back box.
2. Screw the I/O board to the back casing, ensuring to replace the spacers.
micro
SD card
SW2
Mount the back casing to back box
3b
Wiring Configuration: emerald TS300f + DIU200 + S610s SE
NOTE: On the DIU, if BGU, FIRE and TAMPER are not used the
LABEL
J1
(Serial)
J17
DOOR POS
LOCK POS
REX
INTERLOCK
0V
1 RS485 A
1 RS485 B
RS232 TX
3 RS485 A
3 RS485 B
H0
H1
GND
J3
BGU
COM
FIRE
TAMPER
BUZZ –
BGU
COM
FIRE
TAMPER
BUZZ –
BGU
COM
FIRE
TAMPER
BUZZ –
BUZZ +
BUZZ +
BUZZ +
LK7 LK5
GND
EXT
J10
485B
485A
DRY CONTACT RELAY OUTPUTS: 0-24V DC @ 2A (EXTERNAL SUPPLY)
WET CONTACT RELAY OUTPUTS: 12V DC NOW @ 13A (INTERNAL SUPPLY)
RELAY 2
RELAY 1
LK4
485B
485A
SAFETY GND
OV
RS232 RX
0V
SOUNDER
LED GREEN
LED AMBER
LED RED
D1
D0
EXT
Keypad
J19
INT
connections on J9 must be linked out.
S610s SE Reader
Re-assembling the Terminal
Care should be taken when re-assembling the unit. The front case should
not be left hanging from the ribbon cable while attached to the back case.
Ensure there is adequate network cable length to reach the connectors.
1. Connect the ribbon cable to the I/O board.
J15
J5
J7
J6
INT
12V 0V NO C NC 0V NO C NC 0V 12V
J18
BGU
2. Attach the front case to back case ensuring
the ribbon cable folds below connector J18.
FIRE
REQUEST
TO EXIT
J30
J10
DOOR
POSITION
LOCK
SENSE
GND 12V
JMP1
J11
COM
RDR +12
Loop
SW2
micro
SD card
Configuring the Network
Setting the terminal IP address, SubNet mask and Gateway
1. On the terminal home screen swipe across the Date/Time area from left to right.
J5
J9
BGU
COM
J4 J3
FIRE
TAMPER
BUZZ –
LNK 2
LNK 3
LNK 4
LNK 5
J8 LOCK –
LOCK +
COM
MAINS FAIL
LOCKIN 12V/24V
SUPPLY 12V
- MAGNETIC
LOCK
- PSU 12V
+ 2A min
4. Clip the side panels on to each side of
the terminal covering each of the
mounting screws.
Note: Power is supplied via the DIU PSU
4. Select the IP address field, enter the address and press OK.
5. Press the SubNet mask field, enter address and press OK.
6. If necessary, select the Gateway field, type the address and press OK.
7. Press Done to close the Network menu.
Checking Network Status
1. Press and hold the Reader Address to show the network status indicator.
Terminal has received the onboard database
Terminal has received
configuration settings
from the CDC
Terminal is connected
to the RTC
2. Enter the passcode 67679999 to access the Config Menu.
Note: When the terminal has received a configuration from the server the pass
code changes to 67670000.
3. Press Device settings | Network
3. Screw the front casing to the back
casing using the four security hex screws.
TAMPER
BUZZ +
J1
485A
485B
Ferrite Double
DIU200
GPO J2
COM
REX
DOOR
COM
LOCK
Terminal is connected to network via Ethernet
The terminal is now connected to the AC2000 system and ready to use.
Support
For more information on emerald TS300f, consult the following resources.
Datasheets
Installation Manual
User Guide
http://www.cemsys.com/emerald
http://www.cemsys.com/support
http://www.cemsys.com/support
Sales
Technical Support
cem.sales@tycoint.com
Tel: +44 (0)28 90 456656
Safety and Regulatory Information
WARNING This is a class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take
adequate measures.
Installation of this device should be performed by a qualified person in accordance
to all local regulations. See the emerald Installation Manual for safety information.
Copyright © 2015 Controlled Electronic Management Systems Limited. All rights reserved.
No part of this publication may be produced without the written permission of CEM Systems Limited.
Warnings
Warning
This is a class B product. In a domestic environment this product may
cause radio interference in which case the user may be required to
take adequate measures
Warning
English
Under Industry Canada regulations, this radio transmitter may only
operate using an antenna of a type and maximum (or lesser) gain
approved for the transmitter by Industry Canada.
To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically
radiated power (e.i.r.p.) is not more than that necessary for successful
communication.
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause
undesired operation of the device.
Français
Conformément à la réglementation d'Industrie Canada, le présent
émetteur radio peut fonctionner avec une antenne d'un type et d'un
gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie
Canada.
Dans le but de réduire les risques de brouillage radioélectrique à
l'intention des autres utilisateurs, il faut choisir le type d'antenne et
son gain de sorte que la puissance isotrope rayonnée équivalente
(p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une
communication satisfaisante.
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Warning - For FCC Labelled emerald Terminals
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept an interference received, including
interference that may cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth
for an uncontrolled environment. End users must follow the specific
operating instructions for satisfying RF exposure compliance. This
transmitter must not be co-located or operating in conjunction with
any other antenna or transmitter.
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate
the equipment.
Installation of this device shall be performed by a qualified person in
accordance to all local regulations.
This system must be installed within the protected premise in accordance with the National Electrical Code (NFPA70), and the local
authorities having jurisdiction.
Equipment changes or modifications without the approval of the party
responsible for compliance could void the user's authority to operate
the equipment and could create a hazardous condition.
CEM emerald
Intelligent Fingerprint
Terminal product codes
CARD READ
TECHNOLOGY
TS100F
TS200F
TS300F
FCC ID NUMBER
IC ID NUMBER
Mifare CSN
TSR/100/115
TSR/200/115
TSR/300/115
QABTSR618V93F
12009A-TSR618V93F
Picopass
TSR/100/116
TSR/200/116
TSR/300/116
QABTSR618V93F
12009A-TSR618V93F
CEM DESFire
TSR/100/117
TSR/200/117
TSR/300/117
QABTSR618V93F
12009A-TSR618V93F
iClass &
iClass SE
TSR/100/118
TSR/200/118
TSR/300/118
QABTSR618V93F
12009A-TSR618V93F
multi smart
card reader
TSR/100/618
TSR/200/618
TSR/300/618
QABTSR618V93F
12009A-TSR618V93F
Note: The typical read range for the integrated 13.56MHz
read-head is 3 – 5cm (1.2” – 2”)
Supported card technologies
The emerald Intelligent Fingerprint Terminal multi smart card
reader supports the following card technologies:
• CEM DESFire
• MIFARE CSN
• iClass

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Create Date                     : 2015:09:30 15:07:58+01:00
Modify Date                     : 2015:09:30 15:07:58+01:00
Author                          : pthompson
Subject                         : 
Page Count                      : 3
Page Layout                     : SinglePage
Page Mode                       : UseNone
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:26e854fc-69d8-11e5-0000-bfd2ad630eda
Producer                        : PDFCreator 2.1.1.0
Keywords                        : 
Creator Tool                    : PDFCreator 2.1.1.0
Document ID                     : uuid:26e854fc-69d8-11e5-0000-bfd2ad630eda
Format                          : application/pdf
Title                           : 15. Emerald Fingerprint Quick Guide
Creator                         : pthompson
Description                     : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QABTSR618V93F

Navigation menu