DOL1000-MF2 (2 Relay)Programming & Installation Manual
INTRODUCTION The DOL1000-MF2 is a versatile keypad that has the option of running wirelessly. The DOL1000- MF2 can work with 6 volts of battery power or 6-24 volts of AC/DC. This keypad can be wired with multiple wireless transmitters. DOL1000-MF2 can store up to 1000 access codes. Guest access codes are also programmable, which are single-use codes for access. After 5 successive incorrect codes, the keypad will lock for 4 minutes  CONNECTION TERMINALS • V+/V-: These terminals will supply power to the transmitter. • ANT: Antenna • RF1-4: The DOL1000-MF2 can control up to 4 different channels. Each RF terminal represents a different channel. • GO: Connects to the green LED • NOGO: Connects to the red LED • KEYPADUTE: Connects to the DOL1000-MF2 lights located in front of the keypad • NO (Normally open): Use N.O. for equipment that requires a temporary surge of electricity to activate. Example, Electric door locks, automated gates, push plates, etc. • COM: Common ground • NC (Normally closed): Use N.C. for equipment that requires a constant flow of electricity to function properly. Example, Magnetic locks, receivers, etc. • BATTERY 6VDC: If deciding to power the DOL1000-MF2 with a battery, then connect the battery to these terminals. • 6-24VAC/DC: If deciding to hardwire the DOL1000-MF2 directly to a power source, use these terminals. • Master Reset Button: Holding this button down for 5 seconds after reconnecting the keypad to its power source will make the keypad beep 3 times. This will indicate that the Master Code has been reset to 1234.   RESETTING THE KEYPAD AND MASTER CODE  Located on the DOL1000-MF2’s circuit board, the red Master Reset Button is used to reset the master code back to 1234. The following steps will reset the master code:  1. Remove the battery or eliminate the power source to the DOL1000-MF2  and wait for 30 seconds for the keypad to completely power off. 2. Press and hold the red Master Reset Button. 3. While holding the red Master Reset Button, reconnect the battery or power source to the DOL1000-MF2.  4. Continue to hold the red Master Reset Button until the keypad beeps 3 times. This will indicate that the Master Code has been reset to 1234.
The very first time that you apply powewr to the keypad, you will hear a series of beeps followed bya regular repeating beep (1 beep at 3 second intervals) that lets you know you are in programmingmode:Enter a 4 digit Master Code that only you will use for programming purposes. Write Master Code here You can now add up to 1000 access codes as well as a flash code (for one use only) and a latchcode to hold open the gate.To add Access Code1934To add Access Codes2413, 888 and 9743(you may add up to 1000different codes)Example - Master Code 1234Access Code: Master Code1   2   3   4 1   9   3   4Sub Mode Access Code Channel Exit1   # 1   #  To remove Access Code1934Master Code1   2   3   4 1   9   3   4Sub Mode Access Code Exit2   # #  To change Master Codefrom 1234 to 4321Master Code1   2   3   4 4   3   2   1Sub Mode New Master Code Exit7   # #  To clear all Access, Flashand Latch codesMaster Code1   2   3   4Sub Mode8   #To add Flash Code 4437(for one use only)Master Code1   2   3   4 4   4   3   7Sub Mode Flash Code Channel3   # 1  To set relay output time 15 seconds (1/2 - 60 seconds)Master Code1   2   3   4 1   5   #  Sub Mode # Seconds5   #To set relay output time 1/2 second 1   2   3   4  0   #  5   #Master Code1   2   3   4 2   4   1   3Sub Mode Access Code Channel Exit1   # 2   #  8   8   8   8 3   #  9   7   4   3 4   #  beep -
     Default Master Code: 1 234Add Access 12 3 4, 1#, Access Code: __ __ __ __ , Channel:1 #Example:  STEP 1: Press 1 2 3 4 STEP 2: Press 1 #  STEP 3: Enter access code __ __ __ __  STEP 4: Press 1 # (multiple beeps confirm) STEP 5: Press *  *   STEP 6: Test new access code. __ __ __ __  (Green light will flash 6 times confirming that the new access code has been accepted.) STEP 8: Proceed to program the keypad to the receiver.STEP 7: Install 433 MHz wireless module (see next page) Codes Use Channel 1 if unsure. The different channels are dependent on the RF terminal used. Any channel can be assigned for devices that connect to normally open/normally closed.  1 2 3 4, 2#, Access Code: __ __ __ __ , # Remove Access Codes  Enter the Access Code you would like to delete. 1 2 3 4, 3#, Guest Code: __ __ __ __ , Channel:1  Add Guest Code  The Guest Code is a one-time use access code. Once used, the number will be cleared from memory. 1 2 3 4, 4#, Toggle Code: __ __ __ __ , Channel:1  Add Access Toggle Code  Entering Access Toggle Code will toggle the keypad to continuously activate. Entering the code again will toggle the keypad off. Dip switch #6 on the circuit board needs to be in the off position in order for this mode to work.TOGGLE MODE ONLY FOR USE WHEN KEYPAD IS HARD WIRED. 1 2 3 4, 5#, Seconds:0-60, # Set Relay Output Time  Set the number of seconds the device will grant access before locking again. 1 2 3 4, 7#, Master Code: __ __ __ __ , # Change Master Code  Changes Master Code. If the Master Code is forgotten, this manual contains instructions on how to reset the Master Code. 1 2 3 4, 8# Clear All Codes This will clear all data except the Master Code.   PROGRAMMING THE DOL1000-MF2 with 433 MHz Module
 INSTALLING THE 433 MHz MODULE  AntennaActivation Wires:Common & Normally Open+-Channel 1Channel 2STEP1: Prepare the 433 MHz moduleSTEP2: Remove (cut) the battery connector   • NOTE: Be sure to connect the power source to  the correct terminals! The battery terminals and the AC/DC terminals are different.• NOTE: Any channel can be assigned for devices  that connect to normally open/normally closed. STEP 3: Install the433 MHz Moduleto the keypad board
DIP SWITCH MODULE INSTALLATION EXAMPLE:  NOTE: Be sure to connect the power source to the correct terminals! The battery terminals and the AC/DC terminals are different. Relay 1Relay 2
DIP SWITCHES1. SOUND2. LED3. LIGHTS4. Not used5. Not used6. WIRELESS MODEa. Switching this dip switch to off will enable the toggle gate feature and switching to the on position will disable the toggle gate feature. Disabling this feature can potentially save battery power in the case that the toggle gate feature has been accidentally activated. Refer to the programming chart for more details with the toggle gate feature.7. Not used8. Not usedChannel 1Channel 2