Controlled Entry Distributors DOL1000-MF2 Remote Controller User Manual Print

Controlled Entry Distributors, Inc. Remote Controller Print

Users Manual

Download: Controlled Entry Distributors DOL1000-MF2 Remote Controller User Manual Print
Mirror Download [FCC.gov]Controlled Entry Distributors DOL1000-MF2 Remote Controller User Manual Print
Document ID2660311
Application IDT8In6lW4sMM5vIfHTaAfGg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize247.02kB (3087769 bits)
Date Submitted2015-06-29 00:00:00
Date Available2015-06-29 00:00:00
Creation Date2015-06-08 16:47:00
Producing SoftwareAdobe PDF library 9.90
Document Lastmod2015-06-24 13:30:35
Document TitlePrint
Document CreatorAdobe Illustrator CC 2014 (Macintosh)

DOL1000-MF2 (2 Relay)
Programming & Installation Manual
INTRODUCTION
The DOL1000-MF2 is a versatile keypad that has the option of running wirelessly. The DOL1000- MF2
can work with 6 volts of battery power or 6-24 volts of AC/DC. This keypad can be wired with
multiple wireless transmitters. DOL1000-MF2 can store up to 1000 access codes. Guest access
codes are also programmable, which are single-use codes for access. After 5 successive incorrect
codes, the keypad will lock for 4 minutes
CONNECTION TERMINALS
•
•
•
•
•
•
•
•
•
•
•
•
V+/V-: These terminals will supply power to the transmitter.
ANT: Antenna
RF1-4: The DOL1000-MF2 can control up to 4 different channels. Each RF terminal represents
a different channel.
GO: Connects to the green LED
NOGO: Connects to the red LED
KEYPADUTE: Connects to the DOL1000-MF2 lights located in front of the keypad
NO (Normally open): Use N.O. for equipment that requires a temporary surge of electricity to
activate. Example, Electric door locks, automated gates, push plates, etc.
COM: Common ground
NC (Normally closed): Use N.C. for equipment that requires a constant flow of electricity to
function properly. Example, Magnetic locks, receivers, etc.
BATTERY 6VDC: If deciding to power the DOL1000-MF2 with a battery, then connect the
battery to these terminals.
6-24VAC/DC: If deciding to hardwire the DOL1000-MF2 directly to a power source, use these
terminals.
Master Reset Button: Holding this button down for 5 seconds after reconnecting the keypad
to its power source will make the keypad beep 3 times. This will indicate that the Master Code
has been reset to 1234.
RESETTING THE KEYPAD AND MASTER CODE
Located on the DOL1000-MF2’s circuit board, the red Master Reset Button is used to reset the master
code back to 1234. The following steps will reset the master code:
1. Remove the battery or eliminate the power source to the DOL1000-MF2 and wait for 30
seconds for the keypad to completely power off.
2. Press and hold the red Master Reset Button.
3. While holding the red Master Reset Button, reconnect the battery or power source to the
DOL1000-MF2.
4. Continue to hold the red Master Reset Button until the keypad beeps 3 times. This will
indicate that the Master Code has been reset to 1234.
The very first time that you apply powewr to the keypad, you will hear a series of beeps followed by
a regular repeating beep (1 beep at 3 second intervals) that lets you know you are in programming
mode:
Enter a 4 digit Master Code that only you will use for programming purposes.
Write Master Code here
You can now add up to 1000 access codes as well as a flash code (for one use only) and a latch
code to hold open the gate.
Example - Master Code 1234
To add Access Code
1934
To add Access Codes
2413, 888 and 9743
beep Master Code
Sub Mode
Access Code
1 2 3 4
1 #
1 9 3 4
Master Code
Sub Mode
Access Code
1 2 3 4
1 #
2 4 1 3
8 8 8 8
9 7 4 3
(you may add up to 1000
different codes)
Channel Exit
Channel Exit
To remove Access Code
1934
Master Code
Sub Mode
Access Code
Exit
1 2 3 4
2 #
1 9 3 4
To add Flash Code 4437
Master Code
Sub Mode
1 2 3 4
3 #
Master Code
Sub Mode
# Seconds
1 2 3 4
5 #
1 5 #
1 2 3 4
5 #
0 #
To change Master Code
from 1234 to 4321
Master Code
Sub Mode
1 2 3 4
7 #
To clear all Access, Flash
and Latch codes
Master Code
Sub Mode
1 2 3 4
8 #
(for one use only)
To set relay output time
15 seconds (1/2 - 60 seconds)
To set relay output time
1/2 second
Access Code:
Flash Code
4 4 3 7
New Master Code
4 3 2 1
Channel
Exit
PROGRAMMING THE DOL1000-MF2 with 433 MHz Module
Default Master Code: 1 2 3 4
1 2 3 4, 1#, Access Code: __ __ __ __ , Channel:1 #
Example:
Add Access
Codes
STEP 1: Press 1 2 3 4
STEP 2: Press 1 #
STEP 3: Enter access code __ __ __ __
STEP 4: Press 1 # (multiple beeps confirm)
STEP 5: Press * *
STEP 6: Test new access code. __ __ __ __ (Green light will flash 6 times
confirming that the new access code has been accepted.)
STEP 7: Install 433 MHz wireless module (see next page)
STEP 8: Proceed to program the keypad to the receiver.
Use Channel 1 if unsure. The different channels are dependent on the RF
terminal used. Any channel can be assigned for devices that connect to normally
open/normally closed.
Remove Access
Codes
1 2 3 4, 2#, Access Code: __ __ __ __ , #
Enter the Access Code you would like to delete.
1 2 3 4, 3#, Guest Code: __ __ __ __ , Channel:1
Add Guest Code
The Guest Code is a one-time use access code. Once used, the number will be
cleared from memory.
1 2 3 4, 4#, Toggle Code: __ __ __ __ , Channel:1
Add Access
Toggle Code
Entering Access Toggle Code will toggle the keypad to continuously activate.
Entering the code again will toggle the keypad off. Dip switch #6 on the circuit
board needs to be in the off position in order for this mode to work.
TOGGLE MODE ONLY FOR USE WHEN KEYPAD IS HARD WIRED.
Set Relay
Output Time
Change Master
Code
Clear All Codes
1 2 3 4, 5#, Seconds:0-60, #
Set the number of seconds the device will grant access before locking again.
1 2 3 4, 7#, Master Code: __ __ __ __ , #
Changes Master Code. If the Master Code is forgotten, this manual contains
instructions on how to reset the Master Code.
1 2 3 4, 8#
This will clear all data except the Master Code.
INSTALLING THE 433 MHz MODULE
STEP1:
Prepare the 433 MHz module
STEP2:
Remove (cut) the battery connector
Antenna
Activation Wires:
Common & Normally Open
STEP 3: Install the
433 MHz Module
to the keypad board
Channel 1
Channel 2
•
NOTE: Be sure to connect the power source to
the correct terminals! The battery terminals
and the AC/DC terminals are different.
•
NOTE: Any channel can be assigned for devices
that connect to normally open/normally
closed.
DIP SWITCH MODULE INSTALLATION EXAMPLE:
Relay 1
Relay 2
NOTE: Be sure to connect the power source to the correct terminals! The battery terminals
and the AC/DC terminals are different.
DIP SWITCHES
1.
2.
3.
4.
5.
6.
SOUND
LED
LIGHTS
Not used
Not used
WIRELESS MODE
a. Switching this dip switch to off will enable the toggle gate feature and switching to the
on position will disable the toggle gate feature. Disabling this feature can potentially
save battery power in the case that the toggle gate feature has been accidentally
activated. Refer to the programming chart for more details with the toggle gate feature.
7. Not used
8. Not used
Channel 1
Channel 2


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Format                          : application/pdf
Title                           : Print
Metadata Date                   : 2015:06:24 13:30:35+08:00
Modify Date                     : 2015:06:24 13:30:35+08:00
Create Date                     : 2015:06:08 16:47-06:00
Creator Tool                    : Adobe Illustrator CC 2014 (Macintosh)
Thumbnail Width                 : 208
Thumbnail Height                : 256
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 19311 bytes, use -b option to extract)
Instance ID                     : uuid:75905280-252c-4329-8f0a-a793ba73fc09
Document ID                     : xmp.did:af574afe-5a89-42cd-bbcf-605987bf20a6
Original Document ID            : uuid:5D20892493BFDB11914A8590D31508C8
Rendition Class                 : proof:pdf
Derived From Instance ID        : uuid:40990833-20c2-ef4a-836a-3824f74678e4
Derived From Document ID        : xmp.did:825114c2-3a5d-4b22-9dc3-c447353ab006
Derived From Original Document ID: uuid:5D20892493BFDB11914A8590D31508C8
Derived From Rendition Class    : proof:pdf
History Action                  : saved, saved
History Instance ID             : xmp.iid:05801174072068118083CAC6A49B0B28, xmp.iid:af574afe-5a89-42cd-bbcf-605987bf20a6
History When                    : 2013:09:18 16:24:47-06:00, 2015:06:08 16:47:01-06:00
History Software Agent          : Adobe Illustrator CS5, Adobe Illustrator CC 2014 (Macintosh)
History Changed                 : /, /
Manifest Link Form              : EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference
Manifest Reference File Path    : /private/var/folders/pq/zxlxql9x13lbwd0684bzlvhr0000gn/T/TemporaryItems/(A Document Being Saved By Illustrator 7)/iMVF1L.tif, /Users/graphicdesign/Documents/Projects/Transmitter Solutions/Dolphin Access Control/DOL1000-MF2-2 Relay/board.tif, /Users/graphicdesign/Documents/Projects/Transmitter Solutions/Dolphin Access Control/DOL1000-MF/transmitter-power-end.tif, /Users/graphicdesign/Documents/Projects/Transmitter Solutions/Dolphin Access Control/DOL1000-MF/DOL100-MF-433Wiring-transmitter.tif, /private/var/folders/pq/zxlxql9x13lbwd0684bzlvhr0000gn/T/TemporaryItems/(A Document Being Saved By Illustrator 9)/BtX34Z.tif
Manifest Reference Document ID  : adobe:docid:photoshop:33d6df7f-4e9f-1178-84c6-bd0a9d01b6a1, A29563F203763BC4BB44455FAFCCAB18, A29563F203763BC4BB44455FAFCCAB18
Manifest Reference Instance ID  : xmp.iid:d58e8abd-3d3d-428c-b130-53b6af80cace, xmp.iid:03801174072068118A6D862FAC129DC2, xmp.iid:0680117407206811A6139D382D2756A2
Ingredients File Path           : /private/var/folders/pq/zxlxql9x13lbwd0684bzlvhr0000gn/T/TemporaryItems/(A Document Being Saved By Illustrator 7)/iMVF1L.tif, /Users/graphicdesign/Documents/Projects/Transmitter Solutions/Dolphin Access Control/DOL1000-MF2-2 Relay/board.tif, /Users/graphicdesign/Documents/Projects/Transmitter Solutions/Dolphin Access Control/DOL1000-MF/transmitter-power-end.tif, /Users/graphicdesign/Documents/Projects/Transmitter Solutions/Dolphin Access Control/DOL1000-MF/DOL100-MF-433Wiring-transmitter.tif, /private/var/folders/pq/zxlxql9x13lbwd0684bzlvhr0000gn/T/TemporaryItems/(A Document Being Saved By Illustrator 9)/BtX34Z.tif
Ingredients Document ID         : adobe:docid:photoshop:33d6df7f-4e9f-1178-84c6-bd0a9d01b6a1, A29563F203763BC4BB44455FAFCCAB18, A29563F203763BC4BB44455FAFCCAB18
Ingredients Instance ID         : xmp.iid:d58e8abd-3d3d-428c-b130-53b6af80cace, xmp.iid:03801174072068118A6D862FAC129DC2, xmp.iid:0680117407206811A6139D382D2756A2
Startup Profile                 : Print
Has Visible Overprint           : True
Has Visible Transparency        : True
N Pages                         : 1
Max Page Size W                 : 8.500000
Max Page Size H                 : 11.000000
Max Page Size Unit              : Inches
Font Name                       : Geneva, Swiss721BT-Light, Swiss721BT-Roman, Swiss721BT-Italic, Swiss721BT-Medium, Swiss721BT-Bold, Swiss721BT-BoldItalic, Symbol, Univers-Bold
Font Family                     : Geneva, Swiss 721 BT, Swiss 721 BT, Swiss 721 BT, Swiss 721 BT, Swiss 721 BT, Swiss 721 BT, Symbol, Univers
Font Face                       : Regular, Light, Roman, Italic, Medium, Bold, Bold Italic, Regular, 65 Bold
Font Type                       : TrueType, Type 1, Type 1, Type 1, Type 1, Type 1, Type 1, TrueType, Type 1
Font Version                    : 10.0d2e2, 2.0-1.0, 2.0-1.0, 003.001, 2.0-1.0, 2.0-1.0, 003.001, 6.1d7e3, 001.000
Font Composite                  : False, False, False, False, False, False, False, False, False
Font File Name                  : Geneva.dfont, SwissBTLig; Swis721 Lt BT, SwissBTRom; Swis721 BT, SwissBTIta; Swis721 It BT, SwissBTMed; Swis721 Md BT, SwissBTBol; Swis721 Bd BT, SwissBTBolIta; Swis721 BdIt BT, Symbol.ttf, UniveBol; Univers 65 Bold
Plate Names                     : Cyan, Magenta, Yellow, Black, PANTONE 187 C
Swatch Groups Colorants Tint    : 100.000000
Swatch Groups Group Name        : Brights
Swatch Groups Group Type        : 1
Swatch Groups Colorants Swatch Name: C=60 M=90 Y=0 K=0
Swatch Groups Colorants Mode    : CMYK
Swatch Groups Colorants Type    : PROCESS
Swatch Groups Colorants Cyan    : 60.000000
Swatch Groups Colorants Magenta : 90.000000
Swatch Groups Colorants Yellow  : 0.003100
Swatch Groups Colorants Black   : 0.003100
Producer                        : Adobe PDF library 9.90
Page Count                      : 8
Creator                         : Adobe Illustrator CC 2014 (Macintosh)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SU7DOL1000-MF2

Navigation menu