Controlled Entry Distributors DOL1000-MF2 Remote Controller User Manual Print
Controlled Entry Distributors, Inc. Remote Controller Print
Users Manual
DOL1000-MF2 (2 Relay) Programming & Installation Manual INTRODUCTION The DOL1000-MF2 is a versatile keypad that has the option of running wirelessly. The DOL1000- MF2 can work with 6 volts of battery power or 6-24 volts of AC/DC. This keypad can be wired with multiple wireless transmitters. DOL1000-MF2 can store up to 1000 access codes. Guest access codes are also programmable, which are single-use codes for access. After 5 successive incorrect codes, the keypad will lock for 4 minutes CONNECTION TERMINALS • • • • • • • • • • • • V+/V-: These terminals will supply power to the transmitter. ANT: Antenna RF1-4: The DOL1000-MF2 can control up to 4 different channels. Each RF terminal represents a different channel. GO: Connects to the green LED NOGO: Connects to the red LED KEYPADUTE: Connects to the DOL1000-MF2 lights located in front of the keypad NO (Normally open): Use N.O. for equipment that requires a temporary surge of electricity to activate. Example, Electric door locks, automated gates, push plates, etc. COM: Common ground NC (Normally closed): Use N.C. for equipment that requires a constant flow of electricity to function properly. Example, Magnetic locks, receivers, etc. BATTERY 6VDC: If deciding to power the DOL1000-MF2 with a battery, then connect the battery to these terminals. 6-24VAC/DC: If deciding to hardwire the DOL1000-MF2 directly to a power source, use these terminals. Master Reset Button: Holding this button down for 5 seconds after reconnecting the keypad to its power source will make the keypad beep 3 times. This will indicate that the Master Code has been reset to 1234. RESETTING THE KEYPAD AND MASTER CODE Located on the DOL1000-MF2’s circuit board, the red Master Reset Button is used to reset the master code back to 1234. The following steps will reset the master code: 1. Remove the battery or eliminate the power source to the DOL1000-MF2 and wait for 30 seconds for the keypad to completely power off. 2. Press and hold the red Master Reset Button. 3. While holding the red Master Reset Button, reconnect the battery or power source to the DOL1000-MF2. 4. Continue to hold the red Master Reset Button until the keypad beeps 3 times. This will indicate that the Master Code has been reset to 1234. The very first time that you apply powewr to the keypad, you will hear a series of beeps followed by a regular repeating beep (1 beep at 3 second intervals) that lets you know you are in programming mode: Enter a 4 digit Master Code that only you will use for programming purposes. Write Master Code here You can now add up to 1000 access codes as well as a flash code (for one use only) and a latch code to hold open the gate. Example - Master Code 1234 To add Access Code 1934 To add Access Codes 2413, 888 and 9743 beep Master Code Sub Mode Access Code 1 2 3 4 1 # 1 9 3 4 Master Code Sub Mode Access Code 1 2 3 4 1 # 2 4 1 3 8 8 8 8 9 7 4 3 (you may add up to 1000 different codes) Channel Exit Channel Exit To remove Access Code 1934 Master Code Sub Mode Access Code Exit 1 2 3 4 2 # 1 9 3 4 To add Flash Code 4437 Master Code Sub Mode 1 2 3 4 3 # Master Code Sub Mode # Seconds 1 2 3 4 5 # 1 5 # 1 2 3 4 5 # 0 # To change Master Code from 1234 to 4321 Master Code Sub Mode 1 2 3 4 7 # To clear all Access, Flash and Latch codes Master Code Sub Mode 1 2 3 4 8 # (for one use only) To set relay output time 15 seconds (1/2 - 60 seconds) To set relay output time 1/2 second Access Code: Flash Code 4 4 3 7 New Master Code 4 3 2 1 Channel Exit PROGRAMMING THE DOL1000-MF2 with 433 MHz Module Default Master Code: 1 2 3 4 1 2 3 4, 1#, Access Code: __ __ __ __ , Channel:1 # Example: Add Access Codes STEP 1: Press 1 2 3 4 STEP 2: Press 1 # STEP 3: Enter access code __ __ __ __ STEP 4: Press 1 # (multiple beeps confirm) STEP 5: Press * * STEP 6: Test new access code. __ __ __ __ (Green light will flash 6 times confirming that the new access code has been accepted.) STEP 7: Install 433 MHz wireless module (see next page) STEP 8: Proceed to program the keypad to the receiver. Use Channel 1 if unsure. The different channels are dependent on the RF terminal used. Any channel can be assigned for devices that connect to normally open/normally closed. Remove Access Codes 1 2 3 4, 2#, Access Code: __ __ __ __ , # Enter the Access Code you would like to delete. 1 2 3 4, 3#, Guest Code: __ __ __ __ , Channel:1 Add Guest Code The Guest Code is a one-time use access code. Once used, the number will be cleared from memory. 1 2 3 4, 4#, Toggle Code: __ __ __ __ , Channel:1 Add Access Toggle Code Entering Access Toggle Code will toggle the keypad to continuously activate. Entering the code again will toggle the keypad off. Dip switch #6 on the circuit board needs to be in the off position in order for this mode to work. TOGGLE MODE ONLY FOR USE WHEN KEYPAD IS HARD WIRED. Set Relay Output Time Change Master Code Clear All Codes 1 2 3 4, 5#, Seconds:0-60, # Set the number of seconds the device will grant access before locking again. 1 2 3 4, 7#, Master Code: __ __ __ __ , # Changes Master Code. If the Master Code is forgotten, this manual contains instructions on how to reset the Master Code. 1 2 3 4, 8# This will clear all data except the Master Code. INSTALLING THE 433 MHz MODULE STEP1: Prepare the 433 MHz module STEP2: Remove (cut) the battery connector Antenna Activation Wires: Common & Normally Open STEP 3: Install the 433 MHz Module to the keypad board Channel 1 Channel 2 • NOTE: Be sure to connect the power source to the correct terminals! The battery terminals and the AC/DC terminals are different. • NOTE: Any channel can be assigned for devices that connect to normally open/normally closed. DIP SWITCH MODULE INSTALLATION EXAMPLE: Relay 1 Relay 2 NOTE: Be sure to connect the power source to the correct terminals! The battery terminals and the AC/DC terminals are different. DIP SWITCHES 1. 2. 3. 4. 5. 6. SOUND LED LIGHTS Not used Not used WIRELESS MODE a. Switching this dip switch to off will enable the toggle gate feature and switching to the on position will disable the toggle gate feature. Disabling this feature can potentially save battery power in the case that the toggle gate feature has been accidentally activated. Refer to the programming chart for more details with the toggle gate feature. 7. Not used 8. Not used Channel 1 Channel 2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Title : Print Metadata Date : 2015:06:24 13:30:35+08:00 Modify Date : 2015:06:24 13:30:35+08:00 Create Date : 2015:06:08 16:47-06:00 Creator Tool : Adobe Illustrator CC 2014 (Macintosh) Thumbnail Width : 208 Thumbnail Height : 256 Thumbnail Format : JPEG Thumbnail Image : (Binary data 19311 bytes, use -b option to extract) Instance ID : uuid:75905280-252c-4329-8f0a-a793ba73fc09 Document ID : xmp.did:af574afe-5a89-42cd-bbcf-605987bf20a6 Original Document ID : uuid:5D20892493BFDB11914A8590D31508C8 Rendition Class : proof:pdf Derived From Instance ID : uuid:40990833-20c2-ef4a-836a-3824f74678e4 Derived From Document ID : xmp.did:825114c2-3a5d-4b22-9dc3-c447353ab006 Derived From Original Document ID: uuid:5D20892493BFDB11914A8590D31508C8 Derived From Rendition Class : proof:pdf History Action : saved, saved History Instance ID : xmp.iid:05801174072068118083CAC6A49B0B28, xmp.iid:af574afe-5a89-42cd-bbcf-605987bf20a6 History When : 2013:09:18 16:24:47-06:00, 2015:06:08 16:47:01-06:00 History Software Agent : Adobe Illustrator CS5, Adobe Illustrator CC 2014 (Macintosh) History Changed : /, / Manifest Link Form : EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference Manifest Reference File Path : /private/var/folders/pq/zxlxql9x13lbwd0684bzlvhr0000gn/T/TemporaryItems/(A Document Being Saved By Illustrator 7)/iMVF1L.tif, /Users/graphicdesign/Documents/Projects/Transmitter Solutions/Dolphin Access Control/DOL1000-MF2-2 Relay/board.tif, /Users/graphicdesign/Documents/Projects/Transmitter Solutions/Dolphin Access Control/DOL1000-MF/transmitter-power-end.tif, /Users/graphicdesign/Documents/Projects/Transmitter Solutions/Dolphin Access Control/DOL1000-MF/DOL100-MF-433Wiring-transmitter.tif, /private/var/folders/pq/zxlxql9x13lbwd0684bzlvhr0000gn/T/TemporaryItems/(A Document Being Saved By Illustrator 9)/BtX34Z.tif Manifest Reference Document ID : adobe:docid:photoshop:33d6df7f-4e9f-1178-84c6-bd0a9d01b6a1, A29563F203763BC4BB44455FAFCCAB18, A29563F203763BC4BB44455FAFCCAB18 Manifest Reference Instance ID : xmp.iid:d58e8abd-3d3d-428c-b130-53b6af80cace, xmp.iid:03801174072068118A6D862FAC129DC2, xmp.iid:0680117407206811A6139D382D2756A2 Ingredients File Path : /private/var/folders/pq/zxlxql9x13lbwd0684bzlvhr0000gn/T/TemporaryItems/(A Document Being Saved By Illustrator 7)/iMVF1L.tif, /Users/graphicdesign/Documents/Projects/Transmitter Solutions/Dolphin Access Control/DOL1000-MF2-2 Relay/board.tif, /Users/graphicdesign/Documents/Projects/Transmitter Solutions/Dolphin Access Control/DOL1000-MF/transmitter-power-end.tif, /Users/graphicdesign/Documents/Projects/Transmitter Solutions/Dolphin Access Control/DOL1000-MF/DOL100-MF-433Wiring-transmitter.tif, /private/var/folders/pq/zxlxql9x13lbwd0684bzlvhr0000gn/T/TemporaryItems/(A Document Being Saved By Illustrator 9)/BtX34Z.tif Ingredients Document ID : adobe:docid:photoshop:33d6df7f-4e9f-1178-84c6-bd0a9d01b6a1, A29563F203763BC4BB44455FAFCCAB18, A29563F203763BC4BB44455FAFCCAB18 Ingredients Instance ID : xmp.iid:d58e8abd-3d3d-428c-b130-53b6af80cace, xmp.iid:03801174072068118A6D862FAC129DC2, xmp.iid:0680117407206811A6139D382D2756A2 Startup Profile : Print Has Visible Overprint : True Has Visible Transparency : True N Pages : 1 Max Page Size W : 8.500000 Max Page Size H : 11.000000 Max Page Size Unit : Inches Font Name : Geneva, Swiss721BT-Light, Swiss721BT-Roman, Swiss721BT-Italic, Swiss721BT-Medium, Swiss721BT-Bold, Swiss721BT-BoldItalic, Symbol, Univers-Bold Font Family : Geneva, Swiss 721 BT, Swiss 721 BT, Swiss 721 BT, Swiss 721 BT, Swiss 721 BT, Swiss 721 BT, Symbol, Univers Font Face : Regular, Light, Roman, Italic, Medium, Bold, Bold Italic, Regular, 65 Bold Font Type : TrueType, Type 1, Type 1, Type 1, Type 1, Type 1, Type 1, TrueType, Type 1 Font Version : 10.0d2e2, 2.0-1.0, 2.0-1.0, 003.001, 2.0-1.0, 2.0-1.0, 003.001, 6.1d7e3, 001.000 Font Composite : False, False, False, False, False, False, False, False, False Font File Name : Geneva.dfont, SwissBTLig; Swis721 Lt BT, SwissBTRom; Swis721 BT, SwissBTIta; Swis721 It BT, SwissBTMed; Swis721 Md BT, SwissBTBol; Swis721 Bd BT, SwissBTBolIta; Swis721 BdIt BT, Symbol.ttf, UniveBol; Univers 65 Bold Plate Names : Cyan, Magenta, Yellow, Black, PANTONE 187 C Swatch Groups Colorants Tint : 100.000000 Swatch Groups Group Name : Brights Swatch Groups Group Type : 1 Swatch Groups Colorants Swatch Name: C=60 M=90 Y=0 K=0 Swatch Groups Colorants Mode : CMYK Swatch Groups Colorants Type : PROCESS Swatch Groups Colorants Cyan : 60.000000 Swatch Groups Colorants Magenta : 90.000000 Swatch Groups Colorants Yellow : 0.003100 Swatch Groups Colorants Black : 0.003100 Producer : Adobe PDF library 9.90 Page Count : 8 Creator : Adobe Illustrator CC 2014 (Macintosh)EXIF Metadata provided by EXIF.tools