Coulisse ABC05 Motor for indoor blinds User Manual ABC 05 U indd
Coulisse B.V. Motor for indoor blinds ABC 05 U indd
Coulisse >
Contents
manual 1
L3
L2
L1
ØD1
Ød1
-
+
-
+
1.
2.
1. 2.
Coulisse B.V., Vonderweg 48, 7468 DC Enter, The Netherlands
indoor use only
ABC-05-U_R0_
1.1A
User Manual
DC Tubular motor
ABC-05
1. General information
1.1 General dimensions
The ABC-05 is a tubular motor to motorize Coulisse Absolute Roller. The tubular motor
is compatible with Coulisse tubes and makes it possible to operate your blind motorised
with minimum noise. The motors are operated with a Coulisse remote control only.
Endpoints and favorite position are set with the remote control. The motor is energy
effi cienct and can also be battery operated.
WARNING: Important safety instructions. Follow all instructions,
since incorrect installation can lead to severe injury.
Do not make repairs yourself. Do not attempt to open the device
or disassemble it. You run the risk of electric shock and voiding
the limited warranty. No user-serviceable parts are inside.
WARNING:
1.2 Performances
1.3 Compatibility
1.4 Connectors and buttons
Program button
12-24V DC -0.6A input
2. Programming and operating
2.1 First use
Step 1: Connect the motor with the 12V powersupply
Program button
(also possible by using ‘SingleSelect’, see manual remote control*)
*Manuals are also available on our website www.coulisse.nl
Step 2: Set the blind in program-mode by pushing the program button
Step 3: Pair the blind to a channel/remote
Choose channel
by pressing
the ChannelSelect button
Pair/unpair by pressing
the program button on the
backside of the remote
Press the up + down button to
change the rotation direction
Step 4: Switch the rotating direction
Set to program mode:
Shortly press
program button
Program mode:
Blind is
stepping...
1 sec
Action confi rmed:
blind stops stepping
for 3 seconds
Action confi rmed:
blind stops stepping
for 3 seconds
If you press down
and the blind goes up,
the rotation direction
of the blind
has to be switched.
Set the blind in program
mode and follow
this step.
12-24V DC -0.6A input
We refer to the manual of the Coulisse Remote control to set the addtional blind settings.
2.4 Additional blind settings
5. Service & Support
4.2 Cleaning
Follow these general rules when cleaning the outside of the device and its components:
- Make sure the device is unplugged.
- Use a damp, soft, lint-free cloth. Avoid getting moisture in openings.
- Don’t use aerosol sprays, solvents, alcohol, or abrasives.
Do not make repairs yourself. Do not attempt to open the device or
disassemble it. You run the risk of electric shock and voiding the limited
warranty. No user-serviceable parts are inside.
WARNING:
Do not make repairs yourself. Do not attempt to open the device
or disassemble it. You run the risk of electric shock and voiding
the limited warranty. No user-serviceable parts are inside.
WARNING:
- Do not let children play with the blind and/or remote control.
- Only use powersupplies or batteries that comply with the specifi cations on the motor.
- In case of malfunction, unplug the device or remove the batteries and contact your dealer.
- Take care that the blind can move freely and is not blocked by objects.
- Take care that the powersupply cable is out of reach for children.
- Do not paint the device.
- Keep the device dry.
Online Resources
For the latest information and updated manuals go to www.coulisse.nl.
Obtaining Warranty Service
First follow the advice in this booklet and then go to your local dealer.
If the product appears to be damaged or does not function properly, go to your local dealer
for instructions on how to obtain warranty service.
3. Tips & Troubleshooting
Please check www.coulisse.nl for the latest tips and troubleshooting guide
Disclaimer:
© Copyright Coulisse
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, by any means,
electronic, mechanical, photocopying, recording, digital or otherwise without the written permission of the publisher.
Although this manual has been composed with the most care, Coulisse B.V. does not accept any responsibility for damage due to
mistakes and/or faults in this manual.
Coulisse B.V. reserves the right to revise the manual and to revise and/or changes its content at any time, without obligation to notify any
person or entity of such revisions or changes.
The most recent version replaces older versions of this manual. The most recent version is available at ww.coulisse.nl or contact your
Coulisse contact person .
We invite you to send remarks and comments about this manual to Coulisse at manuals@coulisse.nl.
Shortly press program
button ( <2 sec. )
Program mode:
Blind is
stepping...
- Reset to factory defaults & Erase all paired channels/remotes
Hold program button for 10 sec.
untill blind stops stepping
2.2 Normal use
- Manual Control
Hold program button
for more than 2 sec.
Blind moves as
long as button is
pressed
(max. 15 sec.)
For moving in opposite
direction release button
and hold program button
again for more than 2 sec.
2.3 Reset
Shortly press program
button ( <2 sec. )
Program mode:
Blind is
stepping...
- Reset to factory defaults
Hold program button for 15
sec. untill blind stops stepping
and steps once
1 sec
15 sec
Step 6: Exit the program-mode by pressing the program button again
Then set the lower endposition
Step 5: Set endpositions (the positions can also be set after fi rst installation)
Use the up and down
buttons to go to
the lower endposition
Set the position
by pressing
the center + up button
Action confi rmed:
blind stops stepping
for 3 seconds
Action confi rmed:
blind stops stepping
for 3 seconds
Exit program mode:
Shortly press
program button
1 sec 10 sec
>2 sec
Type Power supply Rated power Torq - rpm Operating
temp.
Max. channels to
pair
ABC-05 12-24V DC 0.6A - 7W 0.8Nm - 28 rpm 5°-60° 32 channels
Type Roller Venetian Other
ABC-05 28, 30, 35mm - -
OR
Additional blind settings: Available
Switch rotation direction Yes
Favorite position Yes
BatteryMode Yes
4. Safety & Cleaning
Use the up and down
buttons to go to
the upper endposition
Set the position
by pressing
the center + down button
First set the upper endposition
Type L1 L2 L3 Ø D1 Ø d1
ABC-05 250 11 243 40 26.5
4.1 Safety
GB1