Coulisse ABC06 Tubular Motor User Manual ABC 0607MC A R0 indd
Coulisse B.V. Tubular Motor ABC 0607MC A R0 indd
Coulisse >
User Manual
1.3 Motor assembly Roller 42/50mm Assembly Manual AC Tubular motors ABC-06, -07 - MC RCU-29-ABC ph1 1.3A 1.3B 1. Assembly 1.1 Compatibility and adapters Motor 1.3C ABC-06/ABC-07 System: Roller Roller Roller Roller 42mm 50mm 65mm 80mm Tube: Drive plug: Adapter: RTU-42 RTU-50 RTU-65 RTU-80 RCU-29-ABC RCU-29-ABC RCU-30-ABC RCU-31-ABC no adapters no adapters RCU-13 RCU-14 1.3D 1.3E 1.4 Motor assembly Roller 65/80mm RCU-30/31/32/33-ABC RCU-13/14 ph1 1.2 Component overview Drive plugs: RCU-29-ABC RCU-30-ABC RCU-32-ABC RCU-31-ABC RCU-13-ABC RCU-14 RCU-14-ABC 1.4A 1.4B 1.4C 1.4D RCU-33-ABC Adapters: RCU-13 Tubes: ph1 RTU-42 RTU-50 RTU-65 RTU-80 1.4F 1.4G ABC-0607-A_R1_GB1 1.4E User Manual AC Tubular motors ABC-06, -07 - MC(120) 3. Position adjustment 1. Upper position Turn the switch upwards and turn the white or red screw until the blind has reached the upper position (select the white or red screw depending on the position of the motor in the blind; you need to rst test this in order to make the selection). The upper position is now set. 2. Lower position Turn the switch downwards and turn the white or red screw until the blind has reached the lower position (select the white or red screw depending on the position of the motor in the blind; you need to rst test this in order to make the selection). The lower position is now set. WARNING: Important safety instructions. Follow all instructions, since incorrect installation can lead to severe injury. WARNING: Do not make repairs yourself. Do not attempt to open the device or disassemble it. You run the risk of electric shock and voiding the limited warranty. No user-serviceable parts are inside. 3. Changing positions: By turning the red or the white screw to the right (+) or to the left you can respectively enlarge the end position or make it smaller. indoor use only Upper position Included adjuster 1. General information White adjuster screw The ABC-06-MC(120), ABC-07-MC(120) are tubular motors to motorize Coulisse Absolute Roller. The tubular motors are compatible with Coulisse tubes and makes it possible to operate your blind motorised with minimum noise. Lower position Red adjuster screw Switch 1.1 General dimensions L1 Ø D1 L2 4. Tips & Troubleshooting L3 Please check www.coulisse.nl for the latest tips and troubleshooting guide Type L1 L2 ABC-06/07-MC(120) 475 L3 17 Ø D1 460 5. Safety & Cleaning 40 WARNING: 1.2 Performances Type Power supply ABC-06-MC ABC-07-MC ABC-06-MC(120) ABC-07-MC(120) Rated power 230V AC 50Hz 230V AC 50Hz 120V AC 60Hz 120V AC 60Hz Torq - rpm 0.53A - 121W 0.53A - 121W 0.85A - 102W 0.89A - 92W 5Nm - 30 rpm 10Nm - 15 rpm 6Nm - 33 rpm 10Nm - 21 rpm Max. revolutions Weight [gram] IP 30 30 30 30 1750 1750 1750 1750 44 44 44 44 Do not make repairs yourself. Do not attempt to open the device or disassemble it. You run the risk of electric shock and voiding the limited warranty. No user-serviceable parts are inside. Do not let children play with the blind and/or remote control. Only use powersupplies or batteries that comply with the cations speci on the motor. In case of malfunction, unplug the device or remove the batteries and contact your dealer. Take care that the blind can move freely and is not blocked by objects. Take care that the powersupply cable is out of reach for children. Do not paint the device. Keep the device dry. Follow these general rules when cleaning the outside of the device and its components: General Max. operating time Operating Temp. Len gth w ire 4 min. 5 - 60°C 2 m tr - Make sure the device is unplugged. - Use a damp, soft, lint-free cloth. Avoid getting moisture in openings. - Don’t use aerosol sprays, solvents, alcohol, or abrasives. 6. Service & Support WARNING: 1.3 Compatibility Type Roller A B C -0 6 -M C (12 0 ) ABC-07-MC(120) Venetian 42, 50, 65, 80m m 42, 50, 65, 80mm Other 50mm tilt and lift Do not make repairs yourself. Do not attempt to open the device or disassemble it. You run the risk of electric shock and voiding the limited warranty. No user-serviceable parts are inside. Online Resources For the latest information and updated manuals go to www.coulisse.nl. ro m an roman Obtaining Warranty Service First follow the advice in this booklet and then go to your local dealer. If the product appears to be damaged or does not function properly, go to your local dealer for instructions on how to obtain warranty service. 2. Connecting diagram IMPORTANT: When the mains cable is permanently connected, a readily accessible disconnect device shall be incorporated external to the motor. When there is a pluggable connecter installed on the mains cable, the socket-outlet shall be installed near the motor and shall be easily accessible. Attention: 1. Do not wire two or more motors to one single pole switch or relay. 2. Do not control one motor from several locations without using a proper controller. 3. Do not connect the brown wire and the black wire at the same time to the powersource, this may permanently damage the motor. Disclaimer: © Copyright Coulisse All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, by any means, in any form, electronic, mechanical, photocopying, recording, digital MS 1 230V 120V Neutral (1) Direction 1 (2) Direction 2 (3) Ground (4) Blue Brown Black Green/Yellow White Red Black Green or otherwise without the written permission of the publisher. Although this manual has been composed with the most care, Coulisse B.V. does not accept any responsibility for damage due to mistakes and/or faults in this manual. Coulisse B.V. reserves the right to revise the manual and to revise and/or changes its content at any time, without to notify obligation any person or entity of such revisions or changes. The most recent version replaces older versions of this manual. The most recent version is available at ww.coulisse.com act or cont your Coulisse contact person . We invite you to send remarks and comments about this manual to Coulisse at manuals@coulisse.com. Coulisse B.V., Vonderweg 48, 7468 DC Enter, The Netherlands FCC STATEMENT 1.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)This device must accept any interference received, including interference that may cause undesired operation. 2.Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. ABC-0607MC-U_R1_ GB1 Mains cable M S2 NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Irene Create Date : 2012:05:29 10:51:04+08:00 Modify Date : 2012:07:12 15:37:17+08:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2012:07:12 15:37:17+08:00 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Title : ABC-0607MC-A_R0.indd Creator : Irene Document ID : uuid:66b24dc0-2bec-4cd0-806e-8dda8e71e0ae Instance ID : uuid:cd31e37c-a492-4abd-ae4e-f5eb83fafce3 Producer : Acrobat Distiller 9.0.0 (Windows) Page Count : 3 For : Administrator, Bounding Box : 42 1 734 1130 Container Version : 11 Creator Version : 14 Image Height : 1129 Image Width : 692 Image Size : 692x1129 Megapixels : 0.781EXIF Metadata provided by EXIF.tools