Coulisse ABC23 Curtain Motor User Manual CBB5C3F7CAE92E706466
Coulisse B.V. Curtain Motor CBB5C3F7CAE92E706466
Coulisse >
User Manual
User manual Curtain Motor ABC-23-W120 2.2 Operating 2. Programming and operating 3. Tips & Troubleshooting - Control by remote (see manual remote control) - Manual Control (by pulling) 2.1 First use Please check www.coulisse.com for the latest tips and troubleshooting guide. Step 1: Connect the motor with the powersupply Step 2: Set the curtain in program-mode by pushing the program button (also possible by using âSingleSelectâ, see manual remote control*) 4. Safety & Cleaning 4.1 Safety Pull curtain to start the motor Set to program mode: Shortly press program button WARNING: Curtain moves to end limit - Manual Control (by button) Program mode: Curtain is stepping... Step 3: Pair the curtain to a channel/remote Do not make repairs yourself. Do not attempt to open the device or disassemble it. You run the risk of electric shock and voiding the limited warranty. No user-serviceable parts are inside. Do not let children play with the curtain and/or remote control. Only use powersupplies or batteries that comply with the speciďŹcations on the motor. In case of malfunction, unplug the device or remove the batteries and contact your dealer. Take care that the curtain can move freely and is not blocked by objects. Take care that the powersupply cable is out of reach for children. Do not paint the device. Keep the device dry. 4.2 Cleaning Action conďŹrmed: curtain stops stepping for 3 seconds WARNING: Important safety instructions. Follow all instructions, since incorrect installation can lead to severe injury. WARNING: Do not make repairs yourself. Do not attempt to open the device or disassemble it. You run the risk of electric shock and voiding the limited warranty. No user-serviceable parts are inside. Choose channel by pressing the ChannelSelect button Pair/unpair by pressing the program button on the backside of the remote Hold program button for more than 2 sec. Curtain moves as long as button is pressed (max. 15 sec.) For moving in opposite direction release button and hold program button again for more than 2 sec. 5. Service & Support 2.3 Direct take over From factory default âDirect take overâ is activated. A motor will take over the command directly and runs to itâs endlimit. Switch this function off when it is recommended that the motor must move in small steps. Step 4: Switch the rotating direction indoor use only The ABC-23 is a curtain motor to motorize curtain tracks. The motor can be operated with a coulisse remote control or manually by pulling on the curtain. Limits and favorite position are set with the remote control. 1.1 General dimensions Action conďŹrmed: curtain stops stepping for 3 seconds 5 sec Shortly press program button Press the left + right to change the rotation direction 250 WARNING: Do not make repairs yourself. Do not attempt to open the device or disassemble it. You run the risk of electric shock and voiding the limited warranty. No user-serviceable parts are inside. Online Resources For the latest information and updated manuals go to www.coulisse.com. If you press left and the curtain goes right, the rotation direction of the curtain has to be switched. 1. General information Follow these general rules when cleaning the outside of the device and its components: - Make sure the device is unplugged. - Use a damp, soft, lint-free cloth. Avoid getting moisture in openings. - Donât use aerosol sprays, solvents, alcohol, or abrasives. Program mode: Blind is stepping... Obtaining Warranty Service First follow the advice in this booklet and then go to your local dealer. If the product appears to be damaged or does not function properly, go to your local dealer for instructions on how to obtain warranty service. Hold program button untill blind stops stepping (5 sec. ) 2.4 Reset - Reset to factory defaults 52 Step 5: Set endpositions First set the left endposition 15 220 70 10 sec 2. Type Power Supply Rated Power Torq-Speed Curtain weight ABC-23-W ABC-23-W120 230V AC 50Hz 120V AC 60Hz 0.23A - 45W 0.46A - 45W 0,8Nm, 20 cm/s 0,8Nm, 24 cm/s 50kg 50kg Type Max operating time Operating temp. Max. channels to pair Deg. of protection 4 min. 5 - 60° 32 channels IP20 ABC-23-W & W(120) Use the left and right buttons to go to the left endposition Action conďŹrmed: curtain stops stepping for 3 seconds 1. 1.2 Performances Set the position by pressing the center + left button Shortly press program button Program mode: is stepping... Hold program button untill curtain stops stepping for the second time (ca. 10 sec.) - Reset to factory defaults & Erase all paired channels/remotes Then set the right endposition 1.2A 1. 2. 1.3 Connectors and buttons Use the left and right buttons to go to the right endposition Action conďŹrmed: curtain stops stepping for 3 seconds Set the position by pressing the center + right button Step 6: Exit the program-mode by pressing the program button again Program button 1.3A 15 sec Shortly press program button Program mode: is stepping... Hold program button untill curtain stops stepping and steps once (ca. 15 sec.) 2.5 Additional curtain settings Additional curtain settings: Available Switch rotation direction Favorite position Domotica Box Yes Yes Yes We refer to the manual of the Coulisse Remote control to set the additional curtain settings. Mains cable Neutral Phase Ground 230V 120V Blue Brown Yellow-green White Black Green Exit program mode: Shortly press program button *Manuals are also available on our website www.coulisse.com 1.3B IMPORTANT: When the mains cable is permanently connected, a readily accessible disconnect device shall be incorporated external to the motor. Disclaimer: Š Copyright Coulisse All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, by any means, electronic, mechanical, photocopying, recording, digital or otherwise without the written permission of the publisher. Although this manual has been composed with the most care, Coulisse B.V. does not accept any responsibility for damage due to mistakes and/or faults in this manual. Coulisse B.V. reserves the right to revise the manual and to revise and/or changes its content at any time, without obligation to notify any person or entity of such revisions or changes. The most recent version replaces older versions of this manual. The most recent version is available at ww.coulisse.com or contact your Coulisse contact person. We invite you to send remarks and comments about this manual to Coulisse at manuals@coulisse.com. Coulisse B.V., Vonderweg 48, 7468 DC Enter, The Netherlands ABC-23-U_R0_ GB0 When there is a pluggable connecter installed on the mains cable, the socket-outlet shall be installed near the motor and shall be easily accessible. Assembly Manual Absolute Control Curtain Motor ABC-23-W120 CR-02 CR-01 2.1B 1. Calculations Rail lenght (CR-01-W) = Width - 150mm Belt length (CR-02) = 2 x Width - 50mm Number of runners (CR-11-W) = +/- 8pcs/mtr Ceiling brackets = (CR06-W) = 1pc/mtr 42 22 2.2B CR-11 260 53 62 1A 2. Assembly =1x CR-02 CR-01-W CR-07/08-W CR-14-W CR-04-W CR-06-W =2x CR-03 CR-12 CR-05-W CR-11-W CR-09/10 2.2E 2.1C 2.2C 2.2 Assembling Endcaps CR-09 CR-10 CR-09 CR-09 or CR-13-W CR-09 CR-10 CR-04 ABC-23 2A 2.1 Assembling Belt 2.2F CR-02 CR-12 2.2A =2x 2.1A 2.2D 2.2G ABC-23-A_R0_ GB0 =4x 2.4 Installation bracket ABC-23 2.3 Assemble motor CR-09 CR-06-W 2.2H CR-07-W CR-08-W CR-14 2.4A 2.3A 2.2I CR-05-W ABC-23 2.4B 2.2J 2.3B ABC-23-A_R0_GB0 2.4C NOTICE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this equipment not expressly approved by Shape Technology (Shenzhen) Co., Ltd may void the FCC authorization to operate this equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: is connected. !
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Modify Date : 2012:08:16 16:01:46+08:00 Create Date : 2012:08:15 14:13:42+08:00 Metadata Date : 2012:08:16 16:01:46+08:00 Creator Tool : Adobe InDesign CS4 (6.0.6) Format : application/pdf Title :EXIF Metadata provided by EXIF.toolsCreator : dell Document ID : uuid:34d1cb6c-4411-417a-9806-da96797750e1 Instance ID : uuid:a4987f45-e219-4d79-a09c-27d2f022888c Producer : Acrobat Distiller 9.0.0 (Windows) Page Count : 4 Author : dell