Craftsman 390260293 User Manual PUMP Manuals And Guides L0407610
CRAFTSMAN Pump Manual L0407610 CRAFTSMAN Pump Owner's Manual, CRAFTSMAN Pump installation guides
User Manual: Craftsman 390260293 390260293 CRAFTSMAN PUMP - Manuals and Guides View the owners manual for your CRAFTSMAN PUMP #390260293.
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
SEARS OWNER'S MANUAL MODEL NO. 390.260293 I:RRFTSMRN° CAUTION: Read and Follow All Safety Rulesand Operating Instructions Before FirstUse of This Product. Save ThisManual For Future Reference. PORTABLE 112 H.P. UTILITY/SPRINKLER PUMP • Installation • Operation • Maintenance • Repair Parts Sears, Roebuck and Co., Hoffman Estates, IL 60179 PRINTED IN U.S.A. U.S.A. Form No F642-0201 (Rev. 4/20/04) RULES FOR SAFE INSTALLATION Carefully read manual or on and follow pump. all safety instructions AND OPERATION WARNING ill this _L Pump is supplied with 3-conductor grounding type cord. Connect only to properly grounded, GFCI protected outlet. Do not lilt pump by electrical cord. _This is the safety alert symbol. WJlcll yotl scc this Oll }our punll_ or in this inantlal, look for one of tile ti)llowing signal words and be alert to the potential ior personal injut3'! sylnI_oJ _=_'_ DANGER warns ahout hazards serious personal injury, death if ignored. erty damage Hazardous voltage. Can shock, burn, or cause death. I&WARNING1WARNING warns about hazards that can z cause serious personal injury, death or major property dalnage if ignored. _k CAUTION ]CAUTION can canse damage if ignored. The word important _Pump is non-submersible. Keep motor dry at all times. Do not wash motor. Do not inlmerse. Protect motor from wet weather. that will cause or major prop- Ground pump before connecting to power supply. warns about hazards that will or minor personal injury or property NOTICE indicates special instructions but not related to hazards. which allow water are _IL _usingextension cord, use only UL approved indoor/outdoor, 3-wire, grounding typecord. Do not or receptacle ends to sit in any part of cord or damp locations. Unplug pump before servicing. 1. To avoid risk of serious bodily injury and property damage, read safety instructions carefully before installing pump. 2. Follow local and/or national plumbing and electrical codes when installing pump. _,WARNING ] Hazardous pressure. Pump body may explode if used as a booster pump unless relief valve capable of passing full pump flow at 75 PSi (517 kPa) is installed. 3. _WARNING1 _]To avoid fatal shocks, proceed as fol- lows if pump needs servicing: A Disconnect power to pump outlet box before pulling pump cord plug. After plug is pulled, let pump cool for 20 minutes before attempting to work on it. trapped in pump during steam, leading to explosion Ground Fault Circuit Interrupter grounded outlet for cord plug. Never run pump dry. To do so can damage internal parts, overheat pump (which can cause burns to people handling or servicing pump), and will void warranty! 5. [_ WARNING ]Risk of fire or explosion. gasoline or any other flammable liquids not use pump in atmosphere that flammable fumes or vapors. 6. Do not pump chemicals or corrosive Do not pump with pump. Do might contain liquids witb pump. *Lake Chemical FULL For one year from workmanship. ONE YEAR WARRANTY the date of purchase, ON Sears will repair operation, it may and burns. turn CRAFTSMAN or replace LIMITATION ® 112-HP this pump, OF Co., Chicago, free Illinois UTILITY/SPRINKLER of charge, if defective PUMP in material or LIABILITY SEARS WILL NOT BE LIABLE FOR LOSS OR DAMAGE TO PROPERTY OR ANY INCIDENTAL OR CONSEQUENTIAL EXPENSE FROM PROPERTY DAMAGE DUE DIRECTLY OR IND1RECTL Y FROM THE USE OF THIS PRODUCT LOSS OR Some or exclusion states do not allow may not apply WARRANTY UNITED the exclusion or limitation of incidental or consequential damages, so the above limitation to you. SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS SERVICE CENTER/DEPARTMENT which vary from state to state. STATES. This warranty applies This warranty gives you specific only while Sears, this product is in the United States. legal rights, and you may also have other fights Roebuck and Co., Hoffman Dept. to Pump clean water only with pump. To avoid clogging pump and damage to shaft seal, do not pump water containing solids, foreign material, sand, silt, or abrasives. Always have suction strainer installed when pump is operating. Failure to use strainer may cause pump failure and void warrant3'. Clean strainer and flush out pump after each use. Make sure all hose and pipe connections in suction line are tight. An air leak in suction line will prevent proper priming and reduce performance To prevent damage to pump materials, do not use pipe joint compounds on pump ports. Use only teflon tape or PlastoJoint-Stik* to seal threads. Tighten all piping joints to pump hand tight +1-1/2 tums only. Overtightening may break pump and will void warranty. This unit is not designed for applications involving salt water or brine! Use with salt water or brine will void warranty. (GFCI) 4. pump with If water is NOTICE B. Take extreme care when changing fuses. To reduce chance of fatal electrical shocks, DO NOT stand in water or put your finger in the fuse socket. C. Ground electrical outlet box. D.Use only protected Explosion hazard. Never run Joutlet shut off or blocked. 817WA, Estates, IL 60179 IN THE INSTALLATION Pumping From Lakes, Streams, and Ponds Locate pump as near as possible (vertically) to water source, fn kee l) suction lilt (distance from water to punlp) as low as possible. Place punq_ on level Sul_port. I'rotecl against excess moisture and Ilooding lxmg pipe runs ;rod many litting_ increase friction and reduce flow. Use the smallest possible number of fittings and the shortest possible nm for piping. Support weight of pipe [k" sure water is clear of debris wllieh can dog ptmlp, such as sand, dirt, or scale, l:_esure fl)ot valve and hose are clean and in good condition; scale or dirt in f_)ot valve can cause valve to leak. Valve leakage may cause pump to lose prime, which can result in pump failure Boosting City Water _l, CAUTION i Hazardous lame as a ]lose OtltJct or nozzle Pressure pressure. disch3rgc dosed cxcessi_ c presstlrc. Whcll washer, use only reinhn'ced When using garden line, do not rl.lll r*tlnlp with Ilose tlsillg high or IIOZZ]e ptllllp its pressure I11ay [_tlt'St it frolll high-pressure hose or pipe for disch:u\tge line. When using garden hose. install adapters to pump suction and discharge. Suction hose will require two h'male ends, Either I.ISC it standard washhlg machitle supply hose or modify a short piece of standard 3/4" garden hose as a suction line (see Figures 2A and 2B). (AHIlleCt Stlction hose to tkttlCet on outside of house (see Figure 3, Page 4) and to ptnllp sttction Use 3/4" standard garden hose fi_r discharge. Pump can supply up to 3 sprinklers (depending on GPM output of sprinklers). Piping Both snction and discharge ports arc tapped for 1" NPT (National Pipe Thread) threads. If using hoses, use hose adapters. When pumping from lakes, streams or ponds, use reinforced hose supplied with pump. Ordinary garden hose will collapse and cause pump failure. Keep strainer with l_)ot valve on end of suction hose. Inspect and clean strainer frequently (Figure 1). NOTICE: An air leak in suction pipe may draw air in although no water leaks ()tit. Make sure there arc no air leaks or air pockets in suction pipe. Figure 2A - When Discharge Line (Garden Hose or Rigid Pipe) using pump as a booster pump with hose-connected suction and discharge, install adapters to pump suction and discharge ports. Hose adapter or plastic pipe adapter Priming Plug 115 volt, GFClprote_ed, grounded outlet box. 2374 0396 Suction Line supplied) 2376 0396 Foot valve with strainer (Supplied - clean frequently) Figure I - Typical Installation Figure 2B - Connect pump to spigot for use with sprinklers. Connect with adapters supplied with pump. OPERATION LUBRICATION PRIMING/OPERATION NOTICE: water 1)o not leaking or flooding, All SLIction lift is not priming pump suction run can danlage alld Coilnc'ctioil_, nil)re port water hose thall hclk)re pump iml)ellcr will nltlst dry,. and Running void without Motor €'arising is water is lubricated cl)oh:d Start body pump; (depending above PUMP Make Stll-C suctiotl Fill ptlnlp primp. ill under lO minutes and height of pump st'ill ;it f;Ictor 3' for life iff hearings. ;trail self Ptlnlp Sc:ll lul3ricating warrallty. he airtight. 20 f(.'ct (6. IM). slartillg punlp may dillllage throtlgh _Hazardous wfltage. Can shock, burn, orcause death. Disconnect motor from electrical power before servicing pump. Motor has atito-rcset thermal nverload. If motor overheats, overload will cut off powcr to prevent damage and will reset after nlotor cools. If overload trips repeatedly, check pump l_)r cause (low w)ltage, clogged impeller, etc.). it shotlld on length of water). Figure 3 - Typical sprinkler application. can supply up to three sprinklers. SERVICE Pump _ CAUTION_ Hazardous pressure. Do not shut off hose or sprinklers while pump is running Hose or sprinkler head may cxplode. Figure 4 - Sprinkler pumping from pond. Pump can supply one to three sprinklers depending on conditions. 4 ELECTRICAL _kWARNING Risk shock. Hazardous voltage standing on Dn on wet of dangerous Unplug pump tint handle pump or attempt pump with wet hands or Performance damp or to work while floor. Chart Discharge Suction l)lug immp into 1 IS Volt, 60 Cycle outlet only. Pump is equipped with 3-wire, grounded, cord and plug. 1)o not modify or remove plug. Plug in to properly grounded. grounding type outlet only. Make sure pump circuit meets National Electrical Code (in tSA) or (_anadian Electrical Code (in (_anada). To ;|void dangerous elcctrk:a[ shock hazard, kee l) cord dry :it all times. or fatal electric before servicing it. 5 10 15 Lift Pressure in Pounds 20 Flow per Square 25 in Gallons Inch 30 35 40 Per Minute O' 10.2 10.0 9.7 9.2 8.4 6.9 56 4.2 5' 9.9 9.6 9.4 9.1 7.5 6.1 4.9 3.8 10' 7.9 7.6 7,4 7.2 6.3 5.3 4.0 3.0 15' 6.5 6.4 6.3 6.2 6.0 4.5 3.4 2.5 20' 4.8 4.8 4.8 4.7 4,7 4.2 31 2.2 per Gal. Min. NOTE: Performance cloes not take into account pressure losses in suction and discharge piping, ? ? / \ 2377 0396 Figure 6 - Shroud replacement. Unplug pump before doing any work on it. Be sure that green ground wire is solidly connected to grounding terminal (marked @) before reinstalling shroud. See Steps I and 10, Page 6, for shroud fastenings. 2378 0396 Figure 5 - Capacitor replacement. Unplug pump before doing any work on it. Discharge capacitor by shorting capacitor lead wires together before removing it. 5 PUMP DISASSEMBLY Make stu'c I)o I101 l_ick, _;cr_ltC]l that \oti _n" _zrack or gokl_C do ii_'\\ SEAL REPLACEMENT Step I [_kWARNING1 Risk of electric J shock. Unplug pump before working on it. ,_cr_ttch, AND Step 2 not seal. pLllllp _baft. Make sure scal I_lccs are clean when installing ilew seal. 2379 0496 Step Step 3 Step 4 5 Pull 2382 0496 2383 0496 Step 6 Step Step 7 8 2385 (3496 2386 0496 23840496 Step Step 9 I0 [_ WARNING]Risk of electrical Jshock. Connect =_ C ground pump wire before in shroud. inserting Impeller must not bind on diffuser (inside pump body) at reassembly (Step 9). Turn shaft by hand before tightening pump body bolts to make sure that shaft and impeller are clear of diffuser. 2387 0496 2388 049t 6 REPAIR PARTS 18 17 16 12 19 9 7 6 s \ "\ 4 5 To order parts, call: Sears Product Service, 1-800-366-7278 \ 23 Key No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 • Part Number 101P3410 111P0710 102P1030 111P0370 101P3460 111P0480 102P2840 731S5700 ZBR00010 111P0700 101P1290 121P0090 121P0920 121P1280 102P2010 121R2240 721S1030 751S3230 121P1500 121P4t80 171P5740 121P1940 ZB400960 ZA000020 • Not illustrated. Part Description Pump Body Drain/Priming Port O-Ring Drain/Fill Cap Hose Adapter O-Ring Garden Hose Adapter Venturi O-Ring Venturi/Diffuser Impeller Shaft Seal - Complete Pump Body O-Ring Seal Plate Motor Flat Washer Lock Washer Ground Screw Fan (Includes Key No. 17) Fan Clip Fan Cover Motor Housing (Complete) Washer for Housing Screw Housing Screw Capacitor - 30 microfarad Cap Screw Suction Hose Kit with 1" Foot Valve and Strainer Foot Valve and Strainer - 1" * If motor fails, replace entire pump. 7 Qty. 1 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 [RRFTSMRW OWNER'S MANUAL PORTABLE 112 H.P. UTILITY/SPRINKLER PUMP Model No. 390.260293 Forthe repair or replacementpartsyou need Call 7 am - 7 pro, 7 days a week 1-800-366-PART (1-800-366-7278) For in-homemajorbrandrepair service Call 24 hours a day,7 daysa week 1-800-4-REPAIR (1-800-473-7247) The model number of your Horizontal Tank will be found on a plate attached to the tank. When requesting service or ordering parts, always give the following information: • Product Type • Model Number • Part Number Forthe locationof a SearsRepair ServiceCenterin yourarea Call 24 hours a day,7 daysa week 1-800-488-1222 For informationon purchasinga Sears MaintenanceAgreementor to inquire aboutan existingAgreement call 9 am - 5 pm, Monday-Saturday 1-800-827-6655 SEARS • Part Description Amerrca's Repair Sears, Roebuck and Co., Hoffman Speciahsts Estates, IL 60179 U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 8 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Wed Apr 04 14:41:08 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools