Crane Payment Innovations ONETRACK RFID system User Manual FLST0310 F

MEI RFID system FLST0310 F

User Manual

     2015 Crane Payment Innovations Part No#     UG-FLST0310_F 06/15  Functional GroundingChassis Grounding5. General Specifications:  5.1. Electrical Specifications:  Operating Voltage  Continuous Current  Maximum  Current 12 V DC/ 24 V DC  1.0  A  3 A   Use only current limiting CSA or UL recognized CLASS 2 Power Supply.  5.2. Operating Temperature:  0° ~ 50 ° C (32° ~ 122 °F)  5.3. Total Weight:   Less than 3.5 Kg (7.72 lb)  5.4. Features:     Multi Width 62~85 mm Validator Head           Short Slide Housing Multi I/O         Dual Operating Voltage         Contactless Reader for Cassette         FLS Cassette with RFID Tag  5.5. Enclosed:   Onetrack Enabled Housing Assembly    Validating Head (Part # FLSV-0003)      Mounting Kit ((Part# OPT-MKFLS-HS) FLS Cassette with RFID Tag (Part# FLSCT0002) User's Guide             5.6.   Applicable Patents: 6229317, 6163034, 7104383, 6057683       CPI  |  Crane Payment Innovations 2720 Steeles Ave. West, Units 2-3 Concord, ON, Canada, L4K 4S3  Phone:     +1 905 303-8874  Toll Free:  +1 800 584-2633 Fax:          +1 905 303-8875 Website: www.cranepi.com http://support.cashcode.com     FrontLoad Bill Validator (Onetrack™ Enabled)  FLST0310 User’s Guide                Note:  1) During shipment, switch# 2.3 set to On (Onecheck mode), unless specified by customer. 2) If Harness not supplied, 4 cables from housing requires to be installed on 24 Pin. 3) Default Machine No and Location No to be set to “000000”.
   2015 Crane Payment Innovations  1.  Interface Connector Pin out:   View from the back of the validator  Mating connector CashCode P/N: o  24 Pin socket: 0100455  o  Terminal M1189-2 (JAE P/N DR-SC24-1-7000) TERMINAL SIGNAL  FUNCTION 1  GROUND   GROUND BUS 2  RxD-EXT  RECEIVE DATA (RS232) 3  TxD-EXT  TRANSMIT DATA (RS232) 4  VCC  POWER 5  GND  GROUND  6  RXD-EXT1  RECEIVE DATA 7  GND-EXT/EXT1  INTERFACE GROUND (RS232) 8  TXD-EXT1  TRANSMIT DATA 9  RS485-A  RS485 BUS 10  RS485-B  RS485 BUS 11  INP-RXD  INPUT SIGNAL 12  INP-TTL1  INPUT SIGNAL 13  POWER-  POWER 0V 14  INP-TTL2  INPUT SIGNAL 15  OC-TXD  OUTPUT SIGNAL (OPEN-COLLECTOR ) 16  OC-OUT1  OUTPUT SIGNAL (OPEN-COLLECTOR ) 17  C-LED-BDP / OC-OUT2  LED CATHODE/ OUTPUT SIGNAL  (OPEN-COLLECTOR ) 18  A-LED-BDP  LED ANODE 19  POWER+  POWER 12V/24V 20  TXD-BDP  TRANSMIT DATA (OPTO) 21  RXD-BDP  RECEIVE DATA (OPTO) 22  RST-BDP  MASTER RESET  (OPTO) 23  GND-BDP  INTERFACE GND (OPTO) 24  +12V BDP  INTERFACE POWER (OPTO) We recommend to ground line 1 on the main frame. Also, Interface ground line must be separate from Power (0 V) ground   2. Typical DIP Switches Setting, Currency and Protocol Information:  Please refer to Software Description.  3. Diagnostics: This diagnostics chart is for reference only. Please refer to Software Description for details.  NO OF STATUS LIGHT FLASHES  ERROR DESCRIPTION HARDWARE 1 RED ON BLACK CASSETTE IS REMOVED FROM BILL VALIDATOR 2 RED ON BLACK AN ERROR OCCURRED DURING CPU EXCHANGE WITH MAGNETIC BOARD 3 RED ON BLACK CASSETTE IS FULL 4 RED ON BLACK MECHANICAL JAM IN THE CASSETTE OR STACKER MOTOR FAILURE 5 RED ON BLACK FAILURE OF DIELECTRIC SENSORS 6 RED ON BLACK FAILURE OF OPTICAL SENSORS 7 RED ON BLACK FAILURE OF INDUCTIVE SENSORS 8 RED ON BLACK FAILURE OF TRANSPORTING MOTOR 9 RED ON BLACK SPEED OF TRANSPORTING MOTOR IS TOO FAST 10 RED ON BLACK FAILURE IN ALIGNMENT MECHANISM 11 RED ON BLACK BILL PATHWAY IS NOT EMPTY  12 RED ON BLACK  BILL JAMMED IN ENTRY SLOT OF THE CASSETTE. NO CREDIT GIVEN 13 RED ON BLACK OVERLOAD OF TRANSPORT MOTOR 14 RED ON BLACK SYSTEM ERROR  SOFTWARE 1 GREEN ON RED UNABLE TO WRITE PROGRAM MEMORY 2 GREEN ON RED FIRMWARE INTEGRITY ERROR 3 GREEN ON RED WRONG MEMORY CARD 4 GREEN ON RED SECURITY ERROR   Onetrack FLICKER X 1 CASH BOX IS HOT OR MACHINE# IS MISMATCH FLICKER X 2 ONETRACK CASH BOX / ANTENNA BOARD MODULE ERROR 4.  FCC and IC Information:  FCC ID # QP8ONETRACK. IC # 1297A-ONETRACK. Changes or modifications not approved by the manufacturer could void the user’s authority to operate the equipment.  This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1)  this device may not cause interference. (2)  this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)  l'appareil ne doit pas produire de brouillage. (2)  l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)  this device may not cause harmful interference. (2)  this device must accept any interference received, including interference that may cause undesired operation.  7161213 1819 24

Navigation menu