D and T FS-L2401D LCD Monitor User Manual FS L2401D manual

D&T; Inc. LCD Monitor FS L2401D manual

User Manual

MEDICMEDICAL LCD MONITAL LCD MONITORORUSER'S GUIDEFS-L2401D(FS-L2401D(24" )24" )
English - 1Symbol Definitions 2Safety  Instructions  4Caution 7FCC Information  10Parts  12Connector  13Mechanical Product Drawing   14Control 15Power mangement  18Adjust OSD Menu 19Stansard Signal table 22Signal connector Pin Assignments 23Specification 26Table of Contents
English - 32 - EnglishSymbol DefinitionsThe following symbols appear on the product. its labeling, or theproduct packing. Each symbol carries a special definition, asdefined belowDangerous : High Voltage.Consult accompanying documents.Direct Current.lndicates protective earth ground.DC Power control switch.Serial Number.Top-Bottom.Fragile.Maximum Stacking.Indicats proof of conformity to applicable EuropeanEconmic Community Council directives and to har-monzed standards published in the official journal of theEuropean Communities.Medical Equipment is in accordance with UL 60601-1and CAN/CSA C22.2 No.601.1 in regards to electricshock, fire hazards, and mechanical hazards.Tested to comply with FCC Class B standards.Degrees of protection against the ingress of water.This symbol indicates that the waste of electronic equipment must not be disposed as unsorted municipalwaste and must be collected separately. Please contactthe manufacturer or other authorized disposal companyto decommission your equipement.Do not get wet.Tested to comply with VCCI Class B standards.Tested to comply with CCC standards.
English - 54 - EnglishSafety InstructionsOn Safety1.Before connecting the AC power cord to the DC adapter outlet make sure the voltage designation of the DC adapter correspondsto the local electrical supply.2.Never insert anything metallic into the cabinet openings of the Liquid Crystal Display(LCD) monitor. doing so may create the danger of electric shock.3.To reduce the risk of electric shock, do not remove cover. No user-serviceable parts inside. Only a qualified technician should open the case of the LCD monitor.4.Never use your LCD monitor if the power cord has been damaged. Do not allow anything to rst on the power cord, and keep the cord away from areas where people can trip over it.5.Be sure to hold the plug, not the cord,when disconnecting the LCD monitor from am electric socket.6.Unplug your LCD monitor when it is going to be left unused  for an extended period of time.7.Unplug your LCD monitor from the AC outlet before any service.8.if your LCD monitor does not operate normally-in particular, if there are any unusual sounds or smells coming from it-unplug it immediately am authorized dealer or service center.Warning Do not to touch signal input,signal output or other connectors, andthe patient simultaneously.Warning Extrnal equipment intended for connection to signal input, signaloutput or other connectors, shall comply with relevant IEC stan-dard(e.g.,IEC60950 for IT equipment and IEC60601 series for med-ical electrical equipment).In addition, all such combination-system-shall comply with the stan-dard IEC 60601-1-1, safety requirements for medical electrical sys-tems. Any person who connectors has formed at system and istherefore responsible for the system to comply with the require-ments of IEC 60601-1-1.if,in doubt, contact qualified technician or your local representative.On installation1.Openings in the LCD monitor cabinet are provided for ventilation. To prevent overheating, these openings should not be blocked orcovered. if you put the LCD monitor in a bookcase or some other enclosed space, be sure to provide adequate ventilation.2.Put your LCD monitor in a location with low humidity and a minimum of dust.3.Do not exepose the LCD monitor to rain or use it near water(in kitchens, near swimming pools, etc.). if the LCD monitor accidentally gets wet, unplug it and contact an authorized dealer immediately.You can clean the LCD monitor with a damp cloth ifnecessary, but be sure to unplug the LCD monitor first.5.Locate your LCD monitor near an easily accessible AC outlet.6.High temperature can cause problems. Don't use your LCD monitor in direct sunlight and keep it away from heaters, stoves, fireplaces, and sources of heat.
English - 7.This symbol alerts the user that important literature concerning the operation of this unit has been included.Therefore, it should be read carefully in order to avoidpotential problems. This symbol warms user that un-insulated voltage withinthe unit the may have sufficient magnitude to cause electrical shock. Therefore, it is dangerous to make contact with any part inside the unit. To reduce the risk ofelectric shock, DO NOT remove cover (or back). Thereare no user serviceable parts inside. Refer servicing toqualified service personal. To prevent fire or shock hazards, do not expose this unit to rain ormoisture. Also, do not use this unit's polarized plug with an extension cord receptacle or other outlets unless the prongs canbe fully inserted. The display is designed to meet the medical safety requirements for a patient vicinity device. This device maynot be used in connection with life support equipment. CAUTIONUnderwriters Laboratories (UL) Classification: UL safety Compliance: This LCD monitor is U.L. Classified WITH RESPECT TOELECTRIC SHOCK, FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL 60601-1/CAH/CSA C22.2 NO. 601.1 6 - EnglishEnvironmental Conditions for transport and Storage- Temperature range within -30°C to 85°C- Relative humidity range 5% to 95%Atrnospheric pressure range within 500 to 1060hPs.
English - 98 - EnglishServicingDo not attempt to service the apparatus yourself as opening or removing covers may expose you to dangerous voltages or other hazards, and will void the warranty. Refer all servicing to qualified service personnel.Unplug the apparatus from its power source and refer servicing toqualified personnel under the following conditions:If the power cord or plug is damaged or frayed.If liquid has been spilled into the apparatus.If objects have fallen into the apparatus.If the apparatus has been exposed to rain or moisture If the apparatus has been subjected to excessive shock by beingdropped.If the cabinet has been damaged.If the apparatus seems to be overheated.If the apparatus emits smoke or abnormal odor.If the apparatus fails to operate in accordance with the operatinginstructions.AccessoriesUse only accessories specified by the manufacturer, or sold with the apparatus. This requirement may not be used in the presence offlammable anesthetics mixture with air, oxygen or nitrousoxide. Recycling : Follow local governing ordinances and recycling plans  regarding the recycling or disposal of this requirement. Cleaning Instructions : Follow your hospital protocol for the handling of blood and body fluids. Clean the display with a diluted mixture of mild detergent and water. Use a soft towel or swab. Use of certain cleaning agnts may cause degrandation to the labels and plastic components of the product. Consult cleanser manufacturer to see if agent is compatiblewith it. Do not allow liquid enter the display.   EEC Safety Compliance: This display unit meets the requirements of EN-60601-1so as to conform to the Medical Device Directive93/42/EEC (general safety information). This monitor complies to the above standards only when used withthe supplied medical grade power supply.JWM1150KA2400F04(Ault korea corp.)The monitor should be powered from a center tapped circuit whenused in the US at voltages over 120 volts. Monitor is intended forcontinuous operation. This display is energized from an external electrical power sourcefor class 1 equipment. It Is the responsibility of the installer to testthe display's earth ground to verify that it complies with the hospital,local and nation impedance requirements.
English - 1110 - EnglishPowering On The Unit :1. Connect the power supply to the display via the power plug. 2. Plug in the DC adapter to AC inlet with power cord cable.3. Connect the video source to this monitor.4. Apply power to the peripheral device.5. Turn on the switch of this monitor.Quick StartupFCC InformationThis equipment has been tested and found to comply with the limits of a Class Bdigital device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against interference.This monitor can radiate radio frequency energy and, if not installed and used inaccordance with the instructions, it may interfere with other radio communicationsequipment. There is no guarantee that interference will not occur in a particularinstallation. If this equipment is found to cause harmful interference to radio ortelevision reception, the user is encouraged to try to correct the interference bycarrying out one or more of the following measures:1. Reorient or relocate the receiving antenna.2. Increase the distance between the color monitor and the subject of interference.3. Plug the monitor into a outlet on a different electrical circuit than that to which the subject of interference is connected.4. Consult the dealer or an experienced radio/TV technician for help.NOTICES TO USER : This device complies with part 15 of the FCC Rules. Operation is subject to thefollowing two conditions:(1) this device may not cause harmful interference, and (2) this device mustaccept any interference received, including interference that may cause unde-sired operation.FCC WARNING : This equipement geneates or uses radio frequency energy. Changes or modifications to this equipement may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user couldlose authority to operate this equipment if an unauthorized change or modificationis made.
English - 1312- EnglishAC ON/OFF SWITCHAC InletOPTICAL INDVI INDVI OUTVGA INRS232CSDI INSDI OUTS-VIDEO/YS-VIDEO/CC-VIDEO RED /PrGREEN/YBLUE/PbC-SYNC/H-SYNCV-SYNCTOUCH(OPTION)Back Panel JacksConnector 24" LCD MonitorAccessoriesPartsUser  Manual  D-SUB Cable AC Adapter S-Video (Y/C) CableDVI Cable  BNC Cable AC Power code(Hospital Grade) DC Cable Terminal male / female (Option)SCREW FH M3X6(Option)
English - 1514 - EnglishOSD Button PositionControlMechanical Product Drawing
English - 1716 - English- (MINUS) : With OSD deactivated, Hot key of the contrastcontrol and decreases the contrast. With OSD activated, decreases the adjustment of the selected function. + (PLUS) :  With OSD deactivated, Hot key of the contrast control and increase the contrast. With OSD activated, enter sub menu and increases the adjustment of the selected function. INPUT :  Change the display signal source. If D-SUB Analog's picture size not matched with fullscreen size or image is noisy press the input buttomduring 2~3 seconds then you can see the most appropriate screen678An 8 button keypad, located in button light corner on the front of thedisplay, allows the user to make adjustments to various displayparameters using the On Screen Display (OSD) system. Power Indicating LED Green : Normal mode Red : Standby mode OFF : Monitor OffOn-Screen Display (OSD) Function Button POWER : Turns ON/OFF the monitor. MENU : With OSD deactivated, Activated to OSD menu. With OSD activated, Exit from main menu or sub menu. PIP : With OSD deactivated, Hot key of PIP mode. UP ( ) : With OSD deactivated, Hot key of the brightness control and increases the brightness. With OSD activated, move the cursor upward. selected function. DOWN ( ) : With OSD deactivated, Hot key of the brightnesscontrol and decreases the brightness. With OSD activated, move the cursor downward.12345OSD Button Function
English - 1918 - English495050500ADJUSTBRIGHTNESSCONTRASTSHARPNESSSATURATIONCOLOREXITCVIDEO           NTSC 60Hz/3.58MHzMOVESELECTBACK LIGHT 100Adjust495050500ADJUSTBRIGHTNESSCONTRASTSHARPNESSSATURATIONCOLOREXITCVIDEO           NTSC 60Hz/3.58MHzMOVESELECTBACK LIGHT 100789SHARPNESSAdjust the sharpness of the displayed image.SATURATIONAdjust the saturation of the image.COLORAdjust the color of the image.1234BRIGHTNESSIncrease or decrease the brightness.(Range: 0~100)CONTRASTIncrease or decrease the Contrast.(Range: 0~100)CLOCKIncrease or decrease the sampling frequency.(Range: 0~100)PHASEIncrease or decrease the Phase level.(Range: 0~100)BACK LIGHTIncrease or decrease the back light dimming level (Range: 0~100)AUTO ADJUSTFit to the most appropriate screen on the D-SUB Analog signal5Adjusting OSD6This monitor does not adhere to the VESA DPMS standard when nosignal is present on the video inputs.Status LED sign       Power ConsumptionNormal Mode             Green  on                     <100W                         Standby Mode Red Blinking <20WPower management
English - 2120 - English50SETUPLANGUAGE ENGLISH20 SECOSD COLOROSD POSITIONDURATIONRESET SETTINGSAUTO SOURCE SELECT ONEXITCVIDEO NTSC 60Hz/3.58MHzMOVESELECTSetup1234LANGUAGEChange the OSD language (8 language)(Korean, English, French, Spanish, German, Chinese, Japanese, Italian)OSD COLOR Adjust the OSD background from white opaque to half translucent.OSD POSITIONChange the osd position. (9 Positions)DURATIONAdjust time until the OSD Menu will disappear after adjusting the menu.(5, 10, 20, 30, 60, 90, 120, 180, 240 seconds)RESET SETTINGSChanges the all OSD value to factory out going status.AUTO SOURCE SELECTDisable of enable auto source select.(ON: Searches through all possible input source untill an active videosource is found.OFF: Video input is manually selected.)PIPLAYOUT PIPEXITCVIDEOMOVESELECTSOURCE COMPONENTSWAPNTSC 60Hz/3.58MHzPIP1235LAYOUTChange the OSD layout. (Single, PIP, PBP1, PBP2)SOURCE Change the secondary source.SWAPSwaps the position and size of the Primary and Secondary image.6505050COLOR TEMPMODE USERREDGREENBLUECVIDEO NTSC 60Hz/3.58MHzMOVESELECTEXITColor temp1234MODEChange the color model. (C1(Redish), C2(greenish). USER)REDRed balance(Only Working with USER mode)  (Range: 0~100)GREENGreen balance(Only Working with USER mode)  (Range: 0~100)BLUEBlue balance(Only Working with USER mode)  (Range: 0~100)5050IMAGEIMAGE SIZE FILL ASPECTNORMALMODE 1H POSITIONV POSITIONFILTER0 1 2 3 4 5 6 7 8OVER SCANIMAGE SETTINGCVIDEO NTSC 60Hz/3.58MHzMOVESELECTEXITImage1234IMAGE SIZEChange the image size (Scaling mode)(Full, Fill aspect, 1:1, Normal, Video, Zoom, video only)H POSITIONAdjust the horizontal position of the displayed source image.(Range: 0~100)V  POSITIONAdjust the vertical position of the displayed source image.(Range: 0~100)FILTERSet the sharpness of image ( Softest, Soft, Normal, Sharp, Sharpest)OVER SCANAdjust the displayed size. (0~8)IMAGE SETTINGAllows selection of one of five user defined image presets.56
English - 2322- English1511 15610Pin No.  Assignment  Pin No.  Assignment 1 Red 9 No Connection2 Green 10 Ground-Sync3 Blue 11 Ground4 Ground 12 DDC Data5  DDC 5V Standby 13  H.SyncCable Connection check 14 V.Sync6 Ground-Red 15 DDC Clock7 Ground-Green 8 Ground-Blue 1817 2491621Pin No.  Assignment  Pin No.  Assignment 1  T.M.D.S. Data2- 13 No Connection2  T.M.D.S. Data2+ 14  +5V Power3  T.M.D.S. Data2 Shield  15  Cable Connection check4  No Connection 16 Hot Plug Detect5  No Connection 17  T.M.D.S. Data0-6  DDC Clock 18 T.M.D.S. Data0+7  DDC Data 19 T.M.D.S. Data0 Shield 8  No Connection 20 No Connection9 T.M.D.S. Data1-   21 No Connection10 T.M.D.S. Data1+ 22 T.M.D.S. Clock Shield 11 T.M.D.S. Data1 Shield 23 T.M.D.S. Clock+12 No Connection 24 T.M.D.S. Clock-Pin No.  Assignment 1 Composite2 Ground VGA (15Pin D-Sub)DVI In,Out  (24Pin DVI-D)C-Video (BNC)Signal connector Pin Assignments 640 X 350 @70Hz720 X 400 @70Hz640 X 480 @60Hz640 X 480 @75Hz800 X 600 @60Hz800 X 600 @75Hz1024 X 768 @60Hz1024 X 768 @75Hz1152 X 864 @60Hz1152 X 864 @75Hz1280 X 1024@75Hz1360 X 768@75Hz1600 X 1200@60Hz1920 X 1080@60Hz1920 X 1200@60Hz31.46931.46931.46937.50037.87946.87548.36360.02354.34867.50079.97647.64974.07767.50074.09970.08770.08259.94075.00060.31775.00060.00475.02960.05375.00075.02559.93659.98160.00059.99925.17528.32425.17531.50040.00049.50065.00078.75080.000108.000135.00084.625130.375 148.500154.125ResolutionHorizontal Frequency (KHz)Vertical Frequency(Hz) Clock Frequency(MHz)PC Supported ModeSMPTE-274MSMPTE-296MSMPTE-260MSMPTE-125MITU-R BT.656SDI Video format1080i  (60 / 59.94 / 50)1080p (30 /29.97 / 25 / 24 / 24sF / 23.98 / 23.98sF) 720p (60 / 59.94 / 50)1035i (60 / 59.94)480i (59.94)576i (50)Standard Signal table Output Signal Description
English - 2524 - EnglishR/Pr B/PbAssignment Pin No.RGBHV/RGBS/YPbPr (BNC)G/Y CS/HS VS13Pin No.  Assignment 1 OPICAL Clock2 OPICAL Blue3 OPICAL Green4 OPICAL RedOPTICAL24123451 Red Pr2 Green Y3 Blue Pb4 H-Sync / C-Sync No Connection5 V-Sync No Connection6 GroundRGBS Y Pb Pr61569Pin No.  Assignment 1 No Connection2 TXD3 RXD4 No Connection5 Ground6 No Connection7 No Connection8 No Connection9 No ConnectionRS232C (D-SUB 9Pin)21Pin No.  Assignment 1 S-VIDEO/Y (Luma)2 S-VIDEO/C (Chroma)3 GroundS-Video (BNC)3Pin No.  Assignment 1 SDI IN2 SDI OUT3 GroundSDI (BNC)213
26 - EnglishType TFT-LCDScreen Size 24 linchMaximum Resolution 1920 X 1200 @ 60HzPixel pitch0.270(H) mm X 0.270(V) mmDisplay Colors 16.7M Contrast Ratio 700:1Viewing Angle 89° / 89° / 89° / 89°Response Time 12 msec(Rising+Falling)Luminance 400cd/mHorizontal Frequency 30KHz~75KHzVertical Frequency 50Hz~75HzMaximum Max 100WStandby Mode Max 20WINPUT, -, +, ,  , PIP, MENU, POWER1XDVI, 1XOptical DVI, 1XD-SUB, 1XBNC (CVBS)Video 2XBNC (SVHS Y/C), 1XBNC (SDI), 5XBNC (Component Y/G, Pb/B, Pr/R, H/CS, VS Input)Video 1XDVI, 1XBNC (SDI) Size and Weight580 386 87.5(mm)/  10KgLCDPanelSynchronizationModel FS-L2401DInputSignalOutSignalPower ConsumptionControl keyFront sideDimensionSpecification Input power DC 24V, 6.25A Max

Navigation menu