D and T FS-L2401D LCD Monitor User Manual FS L2401D manual
D&T; Inc. LCD Monitor FS L2401D manual
D and T >
User Manual
FS-L2401D( 24" ) MEDIC AL LCD MONITOR USER'S GUIDE Table of Contents Symbol Definitions Safety Instructions Caution FCC Information 10 Parts 12 Connector 13 Mechanical Product Drawing 14 Control 15 Power mangement 18 Adjust OSD Menu 19 Stansard Signal table 22 Signal connector Pin Assignments 23 Specification 26 English - 1 Symbol Definitions The following symbols appear on the product. its labeling, or the product packing. Each symbol carries a special definition, as defined below Dangerous : High Voltage. Consult accompanying documents. Maximum Stacking. Indicats proof of conformity to applicable European Econmic Community Council directives and to harmonzed standards published in the official journal of the European Communities. Medical Equipment is in accordance with UL 60601-1 and CAN/CSA C22.2 No.601.1 in regards to electric shock, fire hazards, and mechanical hazards. Direct Current. Tested to comply with FCC Class B standards. lndicates protective earth ground. Degrees of protection against the ingress of water. DC Power control switch. Serial Number. Top-Bottom. Fragile. Do not get wet. 2 - English This symbol indicates that the waste of electronic equipment must not be disposed as unsorted municipal waste and must be collected separately. Please contact the manufacturer or other authorized disposal company to decommission your equipement. Tested to comply with VCCI Class B standards. Tested to comply with CCC standards. English - 3 Safety Instructions On Safety 1.Before connecting the AC power cord to the DC adapter outlet make sure the voltage designation of the DC adapter corresponds to the local electrical supply. 2.Never insert anything metallic into the cabinet openings of the Liquid Crystal Display(LCD) monitor. doing so may create the danger of electric shock. 3.To reduce the risk of electric shock, do not remove cover. No user-serviceable parts inside. Only a qualified technician should open the case of the LCD monitor. 4.Never use your LCD monitor if the power cord has been damaged. Do not allow anything to rst on the power cord, and keep the cord away from areas where people can trip over it. 5.Be sure to hold the plug, not the cord,when disconnecting the LCD monitor from am electric socket. 6.Unplug your LCD monitor when it is going to be left unused for an extended period of time. 7.Unplug your LCD monitor from the AC outlet before any service. 8.if your LCD monitor does not operate normally-in particular, if there are any unusual sounds or smells coming from it-unplug it immediately am authorized dealer or service center. Warning Do not to touch signal input,signal output or other connectors, and the patient simultaneously. 4 - English Warning Extrnal equipment intended for connection to signal input, signal output or other connectors, shall comply with relevant IEC standard(e.g.,IEC60950 for IT equipment and IEC60601 series for medical electrical equipment). In addition, all such combination-system-shall comply with the standard IEC 60601-1-1, safety requirements for medical electrical systems. Any person who connectors has formed at system and is therefore responsible for the system to comply with the requirements of IEC 60601-1-1. if,in doubt, contact qualified technician or your local representative. On installation 1.Openings in the LCD monitor cabinet are provided for ventilation. To prevent overheating, these openings should not be blocked or covered. if you put the LCD monitor in a bookcase or some other enclosed space, be sure to provide adequate ventilation. 2.Put your LCD monitor in a location with low humidity and a minimum of dust. 3.Do not exepose the LCD monitor to rain or use it near water (in kitchens, near swimming pools, etc.). if the LCD monitor accidentally gets wet, unplug it and contact an authorized dealer immediately.You can clean the LCD monitor with a damp cloth if necessary, but be sure to unplug the LCD monitor first. 5.Locate your LCD monitor near an easily accessible AC outlet. 6.High temperature can cause problems. Don't use your LCD monitor in direct sunlight and keep it away from heaters, stoves, fireplaces, and sources of heat. English - 5 CAUTION Environmental Conditions for transport and Storage - Temperature range within -30°C to 85°C - Relative humidity range 5% to 95% Atrnospheric pressure range within 500 to 1060hPs. This symbol alerts the user that important literature concerning the operation of this unit has been included. Therefore, it should be read carefully in order to avoid potential problems. This symbol warms user that un-insulated voltage within the unit the may have sufficient magnitude to cause electrical shock. Therefore, it is dangerous to make contact with any part inside the unit. To reduce the risk of electric shock, DO NOT remove cover (or back). There are no user serviceable parts inside. Refer servicing to qualified service personal. To prevent fire or shock hazards, do not expose this unit to rain or moisture. Also, do not use this unit's polarized plug with an extension cord receptacle or other outlets unless the prongs can be fully inserted. The display is designed to meet the medical safety requirements for a patient vicinity device. This device may not be used in connection with life support equipment. Underwriters Laboratories (UL) Classification: UL safety Compliance: This LCD monitor is U.L. Classified WITH RESPECT TO ELECTRIC SHOCK, FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL 606011/CAH/CSA C22.2 NO. 601.1 6 - English English - 7 EEC Safety Compliance: This display unit meets the requirements of EN-60601-1 so as to conform to the Medical Device Directive 93/42/EEC (general safety information). This monitor complies to the above standards only when used with the supplied medical grade power supply. JWM1150KA2400F04(Ault korea corp.) The monitor should be powered from a center tapped circuit when used in the US at voltages over 120 volts. Monitor is intended for continuous operation. This display is energized from an external electrical power source for class 1 equipment. It Is the responsibility of the installer to test the display's earth ground to verify that it complies with the hospital, local and nation impedance requirements. This requirement may not be used in the presence of flammable anesthetics mixture with air, oxygen or nitrous oxide. Recycling : Follow local governing ordinances and recycling plans regarding the recycling or disposal of this requirement. Servicing Do not attempt to service the apparatus yourself as opening or removing covers may expose you to dangerous voltages or other hazards, and will void the warranty. Refer all servicing to qualified service personnel. Unplug the apparatus from its power source and refer servicing to qualified personnel under the following conditions: If the power cord or plug is damaged or frayed. If liquid has been spilled into the apparatus. If objects have fallen into the apparatus. If the apparatus has been exposed to rain or moisture If the apparatus has been subjected to excessive shock by being dropped. If the cabinet has been damaged. If the apparatus seems to be overheated. If the apparatus emits smoke or abnormal odor. If the apparatus fails to operate in accordance with the operating instructions. Accessories Use only accessories specified by the manufacturer, or sold with the apparatus. Cleaning Instructions : Follow your hospital protocol for the handling of blood and body fluids. Clean the display with a diluted mixture of mild detergent and water. Use a soft towel or swab. Use of certain cleaning agnts may cause degrandation to the labels and plastic components of the product. Consult cleanser manufacturer to see if agent is compatible with it. Do not allow liquid enter the display. 8 - English English - 9 FCC Information Quick Startup This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference. This monitor can radiate radio frequency energy and, if not installed and used in accordance with the instructions, it may interfere with other radio communications equipment. There is no guarantee that interference will not occur in a particular installation. If this equipment is found to cause harmful interference to radio or television reception, the user is encouraged to try to correct the interference by carrying out one or more of the following measures: Powering On The Unit : 1. Connect the power supply to the display via the power plug. 2. Plug in the DC adapter to AC inlet with power cord cable. 3. Connect the video source to this monitor. 4. Apply power to the peripheral device. 5. Turn on the switch of this monitor. 1. Reorient or relocate the receiving antenna. 2. Increase the distance between the color monitor and the subject of interference. 3. Plug the monitor into a outlet on a different electrical circuit than that to which the subject of interference is connected. 4. Consult the dealer or an experienced radio/TV technician for help. NOTICES TO USER : This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC WARNING : This equipement geneates or uses radio frequency energy. Changes or modifications to this equipement may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose authority to operate this equipment if an unauthorized change or modification is made. 10 - English English - 11 Connector Parts Back Panel Jacks 24" LCD Monitor Accessories User Manual DVI Cable D-SUB Cable AC Adapter BNC Cable AC Power code (Hospital Grade) S-Video (Y/C) Cable DC Cable Terminal male / female (Option) AC ON/OFF SWITCH S-VIDEO/Y AC Inlet S-VIDEO/C OPTICAL IN C-VIDEO DVI IN RED /Pr DVI OUT GREEN/Y VGA IN BLUE/Pb RS232C C-SYNC/H-SYNC SDI IN V-SYNC SDI OUT TOUCH(OPTION) SCREW FH M3X6 (Option) 12- English English - 13 Control Mechanical Product Drawing OSD Button Position 14 - English English - 15 OSD Button Function An 8 button keypad, located in button light corner on the front of the display, allows the user to make adjustments to various display parameters using the On Screen Display (OSD) system. Power Indicating LED Green : Normal mode Red : Standby mode OFF : Monitor Off On-Screen Display (OSD) Function Button POWER : Turns ON/OFF the monitor. MENU : With OSD deactivated, Activated to OSD menu. With OSD activated, Exit from main menu or sub menu. PIP : With OSD deactivated, Hot key of PIP mode. UP ( ) : With OSD deactivated, Hot key of the brightness control and increases the brightness. With OSD activated, move the cursor upward. selected function. DOWN ( ) : With OSD deactivated, Hot key of the brightness control and decreases the brightness. With OSD activated, move the cursor downward. 16 - English - (MINUS) : With OSD deactivated, Hot key of the contrast control and decreases the contrast. With OSD activated, decreases the adjustment of the selected function. + (PLUS) : With OSD deactivated, Hot key of the contrast control and increase the contrast. With OSD activated, enter sub menu and increases the adjustment of the selected function. INPUT : Change the display signal source. If D-SUB Analog's picture size not matched with full screen size or image is noisy press the input buttom during 2~3 seconds then you can see the most appropriate screen English - 17 Power management Adjusting OSD This monitor does not adhere to the VESA DPMS standard when no signal is present on the video inputs. ADJUST Status Normal Mode Standby Mode LED sign Green on Red Blinking Power Consumption <100W <20W BRIGHTNESS 49 CONTRAST 50 SHARPNESS 50 SATURATION 50 COLOR BACK LIGHT 100 EXIT SELECT CVIDEO MOVE NTSC 60Hz/3.58MHz Adjust BRIGHTNESS Increase or decrease the brightness. (Range : 0~100) CONTRAST Increase or decrease the Contrast. (Range : 0~100) CLOCK Increase or decrease the sampling frequency.(Range : 0~100) PHASE Increase or decrease the Phase level.(Range : 0~100) BACK LIGHT Increase or decrease the back light dimming level (Range : 0~100) AUTO ADJUST Fit to the most appropriate screen on the D-SUB Analog signal SHARPNESS Adjust the sharpness of the displayed image. SATURATION Adjust the saturation of the image. COLOR Adjust the color of the image. ADJUST EXIT CVIDEO 18 - English BRIGHTNESS 49 CONTRAST 50 SHARPNESS 50 SATURATION 50 COLOR BACK LIGHT 100 SELECT MOVE NTSC 60Hz/3.58MHz English - 19 Setup Color temp COLOR TEMP MODE LANGUAGE 50 GREEN 50 BLUE 50 OSD COLOR Adjust the OSD background from white opaque to half translucent. OSD POSITION Change the osd position. (9 Positions) DURATION Adjust time until the OSD Menu will disappear after adjusting the menu. (5, 10, 20, 30, 60, 90, 120, 180, 240 seconds) RESET SETTINGS Changes the all OSD value to factory out going status. AUTO SOURCE SELECT Disable of enable auto source select. (ON: Searches through all possible input source untill an active video source is found. OFF: Video input is manually selected.) LAYOUT Change the OSD layout. (Single, PIP, PBP1, PBP2) SOURCE Change the secondary source. SWAP Swaps the position and size of the Primary and Secondary image. 50 OSD POSITION RED Red balance (Only Working with USER mode) (Range : 0~100) GREEN Green balance (Only Working with USER mode) (Range : 0~100) MOVE NTSC 60Hz/3.58MHz CVIDEO LANGUAGE Change the OSD language (8 language) (Korean, English, French, Spanish, German, Chinese, Japanese, Italian) 20 SEC DURATION RESET SETTINGS AUTO SOURCE SELECT ON SELECT ENGLISH OSD COLOR USER RED EXIT SETUP MODE Change the color model. (C1(Redish), C2(greenish). USER) EXIT SELECT MOVE CVIDEO NTSC 60Hz/3.58MHz BLUE Blue balance (Only Working with USER mode) (Range : 0~100) Image IMAGE SIZE Change the image size (Scaling mode) (Full, Fill aspect, 1:1, Normal, Video, Zoom, video only) H POSITION Adjust the horizontal position of the displayed source image. (Range : 0~100) V POSITION Adjust the vertical position of the displayed source image. (Range : 0~100) IMAGE IMAGE SIZE FILL ASPECT H POSITION 50 V POSITION 50 FILTER NORMAL OVER SCAN 0 1 2 3 4 5 6 7 8 MODE 1 IMAGE SETTING EXIT CVIDEO SELECT MOVE NTSC 60Hz/3.58MHz PIP PIP FILTER Set the sharpness of image ( Softest, Soft, Normal, Sharp, Sharpest) 20 - English PIP SOURCE COMPONENT SWAP OVER SCAN Adjust the displayed size. (0~8) EXIT LAYOUT IMAGE SETTING Allows selection of one of five user defined image presets. CVIDEO SELECT MOVE NTSC 60Hz/3.58MHz English - 21 Standard Signal table Signal connector Pin Assignments PC Supported Mode VGA (15Pin D-Sub) Resolution Horizontal Frequency (KHz) Vertical Frequency (Hz) Clock Frequency (MHz) 640 X 350 @70Hz 31.469 70.087 25.175 720 X 400 @70Hz 31.469 70.082 28.324 640 X 480 @60Hz 31.469 59.940 25.175 640 X 480 @75Hz 37.500 75.000 31.500 800 X 600 @60Hz 37.879 60.317 40.000 800 X 600 @75Hz 46.875 75.000 49.500 1024 X 768 @60Hz 48.363 60.004 65.000 1024 X 768 @75Hz 60.023 75.029 78.750 1152 X 864 @60Hz 54.348 60.053 80.000 1152 X 864 @75Hz 67.500 75.000 108.000 1280 X 1024@75Hz 79.976 75.025 135.000 1360 X 768@75Hz 47.649 59.936 84.625 1600 X 1200@60Hz 74.077 59.981 130.375 1920 X 1080@60Hz 67.500 60.000 148.500 1920 X 1200@60Hz 74.099 59.999 154.125 SDI Video format Output Signal Description SMPTE-274M 1080i (60 / 59.94 / 50) 1080p (30 /29.97 / 25 / 24 / 24sF / 23.98 / 23.98sF) SMPTE-296M 720p (60 / 59.94 / 50) SMPTE-260M 1035i (60 / 59.94) SMPTE-125M 480i (59.94) ITU-R BT.656 576i (50) 22- English Pin No. Assignment Red Green Blue Ground DDC 5V Standby Cable Connection check Ground-Red Ground-Green Ground-Blue Pin No. 10 11 12 13 14 15 Assignment No Connection Ground-Sync Ground DDC Data H.Sync V.Sync DDC Clock 10 11 15 DVI In,Out (24Pin DVI-D) Pin No. Assignment T.M.D.S. Data2T.M.D.S. Data2+ T.M.D.S. Data2 Shield No Connection No Connection DDC Clock DDC Data No Connection Pin No. Assignment 13 No Connection 14 +5V Power 15 Cable Connection check 16 Hot Plug Detect 17 T.M.D.S. Data018 T.M.D.S. Data0+ 19 T.M.D.S. Data0 Shield 20 No Connection T.M.D.S. Data1- 21 No Connection 10 T.M.D.S. Data1+ 22 T.M.D.S. Clock Shield 11 T.M.D.S. Data1 Shield 23 T.M.D.S. Clock+ 12 No Connection 24 T.M.D.S. Clock- 16 17 24 C-Video (BNC) Pin No. Assignment Composite Ground English - 23 3 S-Video (BNC) RGBHV/RGBS/YPbPr (BNC) Pin No. Assignment S-VIDEO/Y (Luma) S-VIDEO/C (Chroma) Ground Pin No. Assignment RGBS Y Pb Pr Red Pr Green Blue Pb H-Sync / C-Sync No Connection V-Sync No Connection Ground R/Pr G/Y B/Pb CS/HS VS RS232C (D-SUB 9Pin) Pin No. Assignment No Connection TXD RXD No Connection Ground No Connection No Connection No Connection No Connection OPTICAL 24 - English Pin No. Assignment OPICAL Clock OPICAL Blue OPICAL Green OPICAL Red SDI (BNC) Pin No. Assignment SDI IN SDI OUT Ground English - 25 Specification Model LCD Panel Synchro nization FS-L2401D Type TFT-LCD Screen Size 24 linch Maximum Resolution 1920 X 1200 @ 60Hz Pixel pitch 0.270(H) mm X 0.270(V) mm Display Colors 16.7M Contrast Ratio 700:1 Viewing Angle 89° / 89° / 89° / 89° Response Time 12 msec(Rising+Falling) Luminance 400cd/m Horizontal Frequency 30KHz~75KHz Vertical Frequency 50Hz~75Hz Maximum Power Consumption Standby Mode Max 100W Control key Front side INPUT, -, +, Input Signal Video 2XBNC (SVHS Y/C), 1XBNC (SDI), 5XBNC Out Signal Max 20W , PIP, MENU, POWER 1XDVI, 1XOptical DVI, 1XD-SUB, 1XBNC (CVBS) (Component Y/G, Pb/B, Pr/R, H/CS, VS Input) Video 1XDVI, 1XBNC (SDI) Input power DC 24V, 6.25A Max Dimension 26 - English Size and Weight 580 386 87.5(mm)/ 10Kg
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2007:07:19 23:22:04Z Modify Date : 2007:07:24 09:27:46+09:00 Page Count : 15 Creation Date : 2007:07:19 23:22:04Z Producer : Acrobat Distiller 4.0.5 for Macintosh Author : ¼ö Mod Date : 2007:07:24 09:27:46+09:00 Metadata Date : 2007:07:24 09:27:46+09:00 Creator : ¼ö Title : FS-L2401D_manual_¼öÁ¤EXIF Metadata provided by EXIF.tools