D and T FS-L4202D LCD Monitor User Manual FS L4202D Manual finally
D&T; Inc. LCD Monitor FS L4202D Manual finally
D and T >
User Manual
FS-L4202D ( 42" ) MEDIC AL LCD MONITOR USER'S GUIDE Table of Contents Symbol Definitions Safety Instructions Caution FCC Information 10 Parts 15 Connector 16 Mechanical Product Drawing 17 Control 18 Power mangement 21 Adjust OSD Menu 22 Stansard Signal table 25 Signal connector Pin Assignments 26 Specification 29 English - 1 Symbol Definitions The following symbols appear on the product. its labeling, or the product packing. Each symbol carries a special definition, as defined below Dangerous : High Voltage. Consult accompanying documents. Maximum Stacking. Indicats proof of conformity to applicable European Econmic Community Council directives and to harmonzed standards published in the official journal of the European Communities. Medical Equipment is in accordance with UL 60601-1 and CAN/CSA C22.2 No.601.1 in regards to electric shock, fire hazards, and mechanical hazards. Direct Current. Tested to comply with FCC Class B standards. lndicates protective earth ground. DC Power control switch. This symbol indicates that the waste of electronic equipment must not be disposed as unsorted municipal waste and must be collected separately. Please contact the manufacturer or other authorized disposal company to decommission your equipement. Serial Number. Tested to comply with VCCI Class B standards. Top-Bottom. Fragile. Do not get wet. 2 - English English - 3 Safety Instructions On Safety 1. Before connecting the AC power cord to the DC adapter outlet make sure the voltage designation of the DC adapter corresponds to the local electrical supply. 2. Never insert anything metallic into the cabinet openings of the Liquid Crystal Display(LCD) monitor. doing so may create the danger of electric shock. 3. To reduce the risk of electric shock, do not remove cover. No user-serviceable parts inside. Only a qualified technician should open the case of the LCD monitor. 4. Never use your LCD monitor if the power cord has been damaged. Do not allow anything to rst on the power cord, and keep the cord away from areas where people can trip over it. 5. Be sure to hold the plug, not the cord,when disconnecting the LCD monitor from am electric socket. 6. Unplug your LCD monitor when it is going to be left unused for an extended period of time. 7.Unplug your LCD monitor from the AC outlet before any service. 8. if your LCD monitor does not operate normally-in particular, if there are any unusual sounds or smells coming from it-unplug it immediately am authorized dealer or service center. Warning Do not to touch signal input,signal output or other connectors, and the patient simultaneously. 4 - English Warning Extrnal equipment intended for connection to signal input, signal output or other connectors, shall comply with relevant IEC standard(e.g.,IEC60950 for IT equipment and IEC60601 series for medical electrical equipment). In addition, all such combination-system-shall comply with the standard IEC 60601-1-1, safety requirements for medical electrical systems. Any person who connectors has formed at system and is therefore responsible for the system to comply with the requirements of IEC 60601-1-1. if,in doubt, contact qualified technician or your local representative. On installation 1. Openings in the LCD monitor cabinet are provided for ventilation. To prevent overheating, these openings should not be blocked or covered. if you put the LCD monitor in a bookcase or some other enclosed space, be sure to provide adequate ventilation. 2. Put your LCD monitor in a location with low humidity and a minimum of dust. 3. Do not exepose the LCD monitor to rain or use it near water (in kitchens, near swimming pools, etc.). if the LCD monitor accidentally gets wet, unplug it and contact an authorized dealer immediately.You can clean the LCD monitor with a damp cloth if necessary, but be sure to unplug the LCD monitor first. 5. Locate your LCD monitor near an easily accessible AC outlet. 6. High temperature can cause problems. Don't use your LCD monitor in direct sunlight and keep it away from heaters, stoves, fireplaces, and sources of heat. English - 5 CAUTION Environmental Conditions for transport and Storage - Temperature range within -20°C to 60°C - Relative humidity range 10% to 85% Atrnospheric pressure range within 500 to 1060hPa. Intended Use - This TFT-LCD Monitor is as accessory intended for use with Medical Equipment to display alpha, numerical and graphical data. This symbol alerts the user that important literature concerning the operation of this unit has been included. Therefore, it should be read carefully in order to avoid potential problems. This symbol warms user that un-insulated voltage within the unit the may have sufficient magnitude to cause electrical shock. Therefore, it is dangerous to make contact with any part inside the unit. To reduce the risk of electric shock, DO NOT remove cover (or back). There are no user serviceable parts inside. Refer servicing to qualified service personal. To prevent fire or shock hazards, do not expose this unit to rain or moisture. Also, do not use this unit's polarized plug with an extension cord receptacle or other outlets unless the prongs can be fully inserted. The display is designed to meet the medical safety requirements for a patient vicinity device. This device may not be used in connection with life support equipment. Underwriters Laboratories (UL) Classification: UL safety Compliance: This LCD monitor is U.L. Classified WITH RESPECT TO ELECTRIC SHOCK, FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL 606011/CAN/CSA C22.2 NO. 601.1 6 - English English - 7 EEC Safety Compliance: This display unit meets the requirements of EN-60601-1 so as to conform to the Medical Device Directive 93/42/EEC (general safety information). The monitor should be powered from a center tapped circuit when used in the US at voltages over 120 volts. Monitor is intended for continuous operation.(Using Plug for US: 120V rating -5-15P tYPE, 230V rating-615P type) Recycling : Follow local governing ordinances and recycling plans regarding the recycling or disposal of this requirement. Cleaning Instructions : Follow your hospital protocol for the handling of blood and body fluids. Clean the display with a diluted mixture of mild detergent and water. Use a soft towel or swab. Use of certain cleaning agnts may cause degrandation to the labels and plastic components of the product. Consult cleanser manufacturer to see if agent is compatible with it. Do not allow liquid enter the display. Servicing Do not attempt to service the apparatus yourself as opening or removing covers may expose you to dangerous voltages or other hazards, and will void the warranty. Refer all servicing to qualified service personnel. Unplug the apparatus from its power source and refer servicing to qualified personnel under the following conditions: If the power cord or plug is damaged or frayed. If liquid has been spilled into the apparatus. If objects have fallen into the apparatus. If the apparatus has been exposed to rain or moisture If the apparatus has been subjected to excessive shock by being dropped. If the cabinet has been damaged. If the apparatus seems to be overheated. If the apparatus emits smoke or abnormal odor. If the apparatus fails to operate in accordance with the operating instructions. Accessories Use only accessories specified by the manufacturer, or sold with the apparatus. Classification - Protection against electric shock : Class I - Applied Parts : No Applied Parts - Protection against harmful ingress of Eater : IPX0 - Degree of safety in the presence of flammable anesthetics mixture with air or with oxygen or with nitrous oxide. Not suitable for use in the presence of a flammable anesthetics mixture with oxygen or with nitrous oxide. - Mode of operation : Continuous. 8 - English English - 9 FCC Information This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference. This monitor can radiate radio frequency energy and, if not installed and used in accordance with the instructions, it may interfere with other radio communications equipment. There is no guarantee that interference will not occur in a particular installation. If this equipment is found to cause harmful interference to radio or television reception, the user is encouraged to try to correct the interference by carrying out one or more of the following measures: 1. Reorient or relocate the receiving antenna. 2. Increase the distance between the color monitor and the subject of interference. 3. Plug the monitor into a outlet on a different electrical circuit than \that to which the subject of interference is connected. 4. Consult the dealer or an experienced radio/TV technician for help. 1. Guidance and manufacturer's declaration - electromagnetic emissions The FS-L4202D is intended for use in the electromagnetic environment specified below. The customer or the user of the FS-L2401D should assure that it is used in such an environment. RF Emissions CISPR 11 Group 1 RF Emissions CISPR 11 Class B Harmonic emisions IEC 61000-3-2 Electromagnetic environment -guidance Compliance Emission test The FS-L4202D uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment FS-L4202D is suitable for use in ail establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes Voltage fluctuations Complies IEC 61000-3-3 NOTICES TO USER : This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC WARNING : This equipement geneates or uses radio frequency energy. Changes or modifications to this equipement may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose authority to operate this equipment if an unauthorized change or modification is made. 2. Guidance and manufacturer's declaration - electromagnetic immunity FS-L4202D is intended for use in the electromagnetic environment specified below. The customer or the user of FS-L4202D should assure that it is used in such an environment. Immunity test IEC 60601 Test level Electrostatic 6kV Contact 6kV Contact discharge(ESD) 8kV air 8kV air Electrical fast transient/burst IEC 61000-4-4 Electromagnetic environment -guidance Floors should be wood,concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30% IEC61000-4-2 2kV for power supply 2kV for power supply Mains power quality should be that of a lines lines typical commercial or hospital environment. 1kV for input/output 1kV for input/output lines 10 - English Complince level lines English - 11 Surge 1kV differential mode IEC 61000-4-5 2kV common mode 1kV differential mode Mains power quality should be that of a 2kV common mode typical commercial or hospital environment. Immunity test IEC 60601 Test level Recommended separation distance Portable and mobile RF communications Conducted RF IEC 61000-4-6 3 Vrms 3 Vrms 150 kHz to 80MHz 150 kHz to 80MHz Electromagnetic environment -guidance Complince level 80MHz to 800MHz Portable and mobile RF communications equipment should be used no closer to any part of the FS-L4202D, including cables, than 80MHz to 2.5GHz the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Radiated RF IEC 61000-4-3 Recommended separation distance where P is the maximum output power rating of the transmitter in watts (W) 3. Guidance and manufacturer's declaration - electromagnetic immunity 3 V/m 3 V/m where P is the maximum output power rating 80.0 MHz to 2.5 GHz 80.0 MHz to 2.5 GHz of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as deter-mined by an electromagnetic site survey, a should be less than the compliance level in each frequency range. FS-L4202D is intended for use in the electromagnetic environment specified below. The customer or the user of FS-L4202D should assure that it is used in such an environment. NOTE : U is the A.C. mains voltage prior to application of the test level. Immunity test Power frequency (50/60Hz) magnetic field IEC 61000-4-8 Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 12- English IEC 60601 Test level Complince level 3.0A/m 3.0A/m <5 % U (>95 % dip in U ) for 0.5 cycle 40 % U (60 % dip in U ) for 5 cycle 70 % U (30 % dip in U ) for 25 cycle <5 % U¨‰ (<95 % dip in U¨‰ ) for 5 s <5 % U (>95 % dip in U ) for 0.5 cycle 40 % U (60 % dip in U ) for 5 cycle 70 % U (30 % dip in U ) for 25 cycle <5 % U (<95 % dip in U ) for 5 s Electromagnetic environment -guidance Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. Mains power quaility should be that of a typical commercial or hospital environment. If the user of FS-L4202D requires continued operation during power mains interruptions, it is recommended that FS-L4202 be powered from an uninterruptible power supply or a battery 4. Recommended separation distances between portable and mobile RF communications equipment and the FS-L4202D - The is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the FS-L4202D can help - Prevent electromagnetic interference by maintaining a minimum distance between portable and mobile - RF communications equipment (transmitters) and the FS-L4202D as recommended below,according to the maximum output power of the communications equipment. Separation distance according to frequency of transmitter[m] Rated maximum output power of tr ansmitter [W] 150kHz to 80MHz 80MHz to 800MHz 800MHz to 2.5GHz V1=3Vrms E1=3V/m E1=3V/m English - 13 Parts 0.01 0.116 0.116 0.2333 0.1 0.368 0.3687 0.7378 1.166 1.1660 0.2333 10 3.687 3.6872 0.7375 100 11.660 11.6600 23.333 42" LCD Monitor For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m)can be estimated using the equation applicable to the frequency of the transmitter, where p is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1) At 80MHz and 800MHz, the separation distance for the higher frequency range applies. NOTE 2) These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. Quick Startup Powering On The Unit : 1. Connect the power supply to the display via the power plug. 2. Plug in the DC adapter to AC inlet with power cord cable. 3. Connect the video source to this monitor. 4. Apply power to the peripheral device. 5. Turn on the switch of this monitor. Accessories User Manual BNC Cable 14- English D-SUB Cable S-Video (Y/C) Cable DVI Cable AC Power code (Hospital Grade) English - 15 Mechanical Product Drawing Connector Back Panel Jacks 300 600 AC ON/OFF SWITCH S-VIDEO/Y AC Inlet S-VIDEO/C OPTICAL IN C-VIDEO DVI IN RED /Pr DVI OUT GREEN/Y VGA IN BLUE/Pb RS232C C-SYNC/H-SYNC SDI IN V-SYNC 6-M8(USER MUNT HOLE) SDIOUT 16 - English English - 17 Control OSD Button Function OSD Button Position An 8 button keypad, located in button light corner on the front of the display, allows the user to make adjustments to various display parameters using the On Screen Display (OSD) system. Power Indicating LED Green : Normal mode Amber: Standby mode OFF : Monitor off On-Screen Display (OSD) Function Button POWER : Turns ON/OFF the monitor. MENU : With OSD deactivated, Activated to OSD menu. With OSD activated, Exit from main menu or sub menu. PIP : With OSD deactivated, Hot key of PIP mode. UP ( ) : With OSD deactivated, Hot key of the brightness control and increases the brightness. With OSD activated, move the cursor upward. selected function. DOWN ( ) : With OSD deactivated, Hot key of the brightness control and decreases the brightness. With OSD activated, move the cursor downward. 18 - English English - 19 Power management - (MINUS) : With OSD deactivated, Hot key of the contrast control and decreases the contrast. With OSD activated, decreases the adjustment of the selected function. + (PLUS) : With OSD deactivated, Hot key of the contrast control and increase the contrast. With OSD activated, enter sub menu and increases the adjustment of the selected function. INPUT : Change the display signal source. If D-SUB Analog's picture size not matched with full screen size or image is noisy press the input buttom during 2~3 seconds then you can see the most appropriate screen. 20 - English This monitor does not adhere to the VESA DPMS standard when no signal is present on the video inputs. Status Normal Mode Standby Mode LED sign Green on Amber Blinking Power Consumption <260W <20W English - 21 Adjusting OSD Color temp COLOR TEMP MODE ADJUST BRIGHTNESS 49 CONTRAST 50 SHARPNESS 50 SATURATION 50 COLOR BACK LIGHT 100 EXIT SELECT CVIDEO 50 BLUE 50 RED Red balance (Only Working with USER mode) (Range : 0~100) SELECT GREEN Green balance (Only Working with USER mode) (Range : 0~100) BLUE Blue balance (Only Working with USER mode) (Range : 0~100) MOVE NTSC 60Hz/3.58MHz CVIDEO NTSC 60Hz/3.58MHz BRIGHTNESS 49 CONTRAST 50 SHARPNESS 50 SATURATION 50 COLOR BACK LIGHT 22 - English MODE Change the color model. (C1(Redish), C2(greenish). USER) Image ADJUST CVIDEO 50 GREEN MOVE Adjust EXIT RED EXIT USER 100 SELECT BRIGHTNESS Increase or decrease the brightness. (Range : 0~100) IMAGE IMAGE SIZE H POSITION CLOCK Increase or decrease the sampling frequency.(Range : 0~100) EXIT CVIDEO NTSC 60Hz/3.58MHz H POSITION Adjust the horizontal position of the displayed source image. (Range : 0~100) V POSITION Adjust the vertical position of the displayed source image. (Range : 0~100) 50 FILTER NORMAL OVER SCAN 0 1 2 3 4 5 6 7 8 MODE 1 IMAGE SETTING MOVE IMAGE SIZE Change the image size (Scaling mode) (Full, Fill aspect, 1:1, Normal, Video, Zoom, video only) 50 V POSITION CONTRAST Increase or decrease the Contrast. (Range : 0~100) FILL ASPECT SELECT MOVE NTSC 60Hz/3.58MHz PHASE Increase or decrease the Phase level.(Range : 0~100) BACK LIGHT Increase or decrease the back light dimming level (Range : 0~100) FILTER Set the sharpness of image ( Softest, Soft, Normal, Sharp, Sharpest) AUTO ADJUST Fit to the most appropriate screen on the D-SUB Analog signal OVER SCAN Adjust the displayed size. (0~8) SHARPNESS Adjust the sharpness of the displayed image. IMAGE SETTING Allows selection of one of five user defined image presets. SATURATION Adjust the saturation of the image. COLOR Adjust the color of the image. English - 23 Standard Signal table PC Supported Mode Setup SETUP LANGUAGE ENGLISH OSD COLOR 50 Resolution Horizontal Frequency (KHz) Vertical Frequency (Hz) Clock Frequency (MHz) 640 X 350 @70Hz 31.469 70.087 25.175 OSD COLOR Adjust the OSD background from white opaque to half translucent. 720 X 400 @70Hz 31.469 70.082 28.324 640 X 480 @60Hz 31.469 59.940 25.175 OSD POSITION Change the osd position. (9 Positions) 640 X 480 @75Hz 37.500 75.000 31.500 800 X 600 @60Hz 37.879 60.317 40.000 DURATION Adjust time until the OSD Menu will disappear after adjusting the menu. (5, 10, 20, 30, 60, 90, 120, 180, 240 seconds) 800 X 600 @75Hz 46.875 75.000 49.500 1024 X 768 @60Hz 48.363 60.004 65.000 1024 X 768 @75Hz 60.023 75.029 78.750 1152 X 864 @60Hz 54.348 60.053 80.000 1152 X 864 @75Hz 67.500 75.000 108.000 1280 X 1024@75Hz 79.976 75.025 135.000 1360 X 768@75Hz 47.649 59.936 84.625 1600 X 1200@60Hz 74.077 59.981 130.375 1920 X 1080@60Hz 67.500 60.000 148.500 LANGUAGE Change the OSD language (8 language) (Korean, English, French, Spanish, German, Chinese, Japanese, Italian) OSD POSITION 20 SEC DURATION RESET SETTINGS AUTO SOURCE SELECT ON EXIT SELECT MOVE CVIDEO NTSC 60Hz/3.58MHz RESET SETTINGS Changes the all OSD value to factory out going status. AUTO SOURCE SELECT Disable of enable auto source select. (ON: Searches through all possible input source untill an active video source is found. OFF: Video input is manually selected.) PIP PIP LAYOUT PIP SOURCE COMPONENT SWAP EXIT CVIDEO 24 - English SELECT MOVE LAYOUT Change the OSD layout. (Single, PIP, PBP1, PBP2) SOURCE Change the secondary source. SWAP Swaps the position and size of the Primary and Secondary image. SDI Video format Output Signal Description SMPTE-274M 1080i (60 / 59.94 / 50) 1080p (30 /29.97 / 25 / 24 / 24sF / 23.98 / 23.98sF) SMPTE-296M 720p (60 / 59.94 / 50) SMPTE-260M 1035i (60 / 59.94) SMPTE-125M 480i (59.94) ITU-R BT.656 576i (50) NTSC 60Hz/3.58MHz English - 25 Signal connector Pin Assignments VGA (15Pin D-Sub) Pin No. Assignment Red Green Blue Ground DDC 5V Standby Cable Connection check Ground-Red Ground-Green Ground-Blue Pin No. 10 11 12 13 14 15 Assignment No Connection Ground-Sync Ground DDC Data H.Sync V.Sync DDC Clock Pin No. Assignment T.M.D.S. Data2T.M.D.S. Data2+ T.M.D.S. Data2 Shield No Connection No Connection DDC Clock DDC Data No Connection Assignment S-VIDEO/Y (Luma) S-VIDEO/C (Chroma) Ground 10 11 15 DVI In,Out (24Pin DVI-D) Pin No. S-Video (BNC) RS232C (D-SUB 9Pin) Pin No. Assignment 13 No Connection 14 +5V Power 15 Cable Connection check 16 Hot Plug Detect 17 T.M.D.S. Data018 T.M.D.S. Data0+ 19 T.M.D.S. Data0 Shield 20 No Connection T.M.D.S. Data1- 21 No Connection 10 T.M.D.S. Data1+ 22 T.M.D.S. Clock Shield 11 T.M.D.S. Data1 Shield 23 T.M.D.S. Clock+ 12 No Connection 24 T.M.D.S. Clock- 16 17 24 Pin No. Assignment No Connection TXD RXD No Connection Ground No Connection No Connection No Connection No Connection SDI (BNC) C-Video (BNC) Pin No. 26 - English Assignment Composite Ground Pin No. Assignment SDI IN SDI OUT Ground English - 27 Specification RGBHV/RGBS/YPbPr (BNC) Model Assignment RGBS Y Pb Pr Pin No. Red Pr Green Blue Pb H-Sync / C-Sync No Connection V-Sync No Connection Ground R/Pr G/Y B/Pb CS/HS VS LCD Panel Synchro nization OPTICAL Pin No. Assignment OPICAL Clock OPICAL Blue OPICAL Green OPICAL Red FS-L4202D Type TFT-LCD Screen Size 42 linch Maximum Resolution 1920 X 1080 @ 60Hz Pixel pitch 0.4845(H) mm X 0.4845(V) mm Display Colors 16.7M Contrast Ratio 1000:1 Viewing Angle 89° / 89° / 89° / 89° Response Time 10msec(Rising+Falling) Luminance 500cd/m Horizontal Frequency 30KHz~75KHz Vertical Frequency 50Hz~75Hz Maximum Power Consumption Standby Mode 260W Control key Front side INPUT, -, +, Input Signal Video 2XBNC (SVHS Y/C), 1XBNC (SDI), 5XBNC Out Signal Under 20W , PIP, MENU, POWER 1XDVI, 1XOptical DVI, 1XD-SUB, 1XBNC (CVBS) (Component Y/G, Pb/B, Pr/R, H/CS, VS Input) Video 1XDVI, 1XBNC (SDI) Input power AC 100-230V~, 50-60Hz, 3A Max Dimension 28 - English Size and Weight 1024.6 617.4 111.1(mm)/ 29Kg English - 29
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2007:08:06 22:01:44Z Modify Date : 2007:08:06 22:04:41+09:00 Page Count : 16 Has XFA : No Creation Date : 2007:08:06 22:01:44Z Producer : Acrobat Distiller 4.0.5 for Macintosh Author : ¼ö Mod Date : 2007:08:06 22:04:41+09:00 Metadata Date : 2007:08:06 22:04:41+09:00 Creator : ¼ö Title : FS-L4202D_Manual finallyEXIF Metadata provided by EXIF.tools