D and T FS-L4202D LCD Monitor User Manual FS L4202D Manual finally

D&T; Inc. LCD Monitor FS L4202D Manual finally

User Manual

Download: D and T FS-L4202D LCD Monitor User Manual FS L4202D Manual finally
Mirror Download [FCC.gov]D and T FS-L4202D LCD Monitor User Manual FS L4202D Manual finally
Document ID841097
Application IDlL1AXAblVKhGalqAMITn/Q==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize84.49kB (1056142 bits)
Date Submitted2007-09-10 00:00:00
Date Available2007-09-11 00:00:00
Creation Date2007-08-06 22:01:44
Producing SoftwareAcrobat Distiller 4.0.5 for Macintosh
Document Lastmod2007-08-06 22:04:41
Document TitleFS-L4202D_Manual finally
Document CreatorQuarkXPress: AdobePS 8.5.1
Document Author: ¼ö

FS-L4202D ( 42" )
MEDIC AL LCD MONITOR
USER'S GUIDE
Table of Contents
Symbol Definitions
Safety Instructions
Caution
FCC Information
10
Parts
15
Connector
16
Mechanical Product Drawing
17
Control
18
Power mangement
21
Adjust OSD Menu
22
Stansard Signal table
25
Signal connector Pin Assignments
26
Specification
29
English - 1
Symbol Definitions
The following symbols appear on the product. its labeling, or the
product packing. Each symbol carries a special definition, as defined
below
Dangerous : High Voltage.
Consult accompanying documents.
Maximum Stacking.
Indicats proof of conformity to applicable European Econmic
Community Council directives and to harmonzed standards
published in the official journal of the European Communities.
Medical Equipment is in accordance with UL 60601-1 and
CAN/CSA C22.2 No.601.1 in regards to electric shock, fire
hazards, and mechanical hazards.
Direct Current.
Tested to comply with FCC Class B standards.
lndicates protective earth ground.
DC Power control switch.
This symbol indicates that the waste of electronic
equipment must not be disposed as unsorted municipal waste
and must be collected separately. Please contact the
manufacturer or other authorized disposal company to
decommission your equipement.
Serial Number.
Tested to comply with VCCI Class B standards.
Top-Bottom.
Fragile.
Do not get wet.
2 - English
English - 3
Safety Instructions
On Safety
1. Before connecting the AC power cord to the DC adapter outlet make
sure the voltage designation of the DC adapter corresponds to the
local electrical supply.
2. Never insert anything metallic into the cabinet openings of the Liquid
Crystal Display(LCD) monitor. doing so may create the danger of
electric shock.
3. To reduce the risk of electric shock, do not remove cover.
No user-serviceable parts inside. Only a qualified technician should
open the case of the LCD monitor.
4. Never use your LCD monitor if the power cord has been damaged.
Do not allow anything to rst on the power cord, and keep the cord
away from areas where people can trip over it.
5. Be sure to hold the plug, not the cord,when disconnecting the
LCD monitor from am electric socket.
6. Unplug your LCD monitor when it is going to be left unused for an
extended period of time.
7.Unplug your LCD monitor from the AC outlet before any service.
8. if your LCD monitor does not operate normally-in particular, if there
are any unusual sounds or smells coming from it-unplug it
immediately am authorized dealer or service center.
Warning
Do not to touch signal input,signal output or other connectors, and the
patient simultaneously.
4 - English
Warning
Extrnal equipment intended for connection to signal input, signal output
or other connectors, shall comply with relevant IEC
standard(e.g.,IEC60950 for IT equipment and IEC60601 series for
medical electrical equipment).
In addition, all such combination-system-shall comply with the
standard IEC 60601-1-1, safety requirements for medical electrical
systems. Any person who connectors has formed at system and is
therefore responsible for the system to comply with the requirements of
IEC 60601-1-1.
if,in doubt, contact qualified technician or your local representative.
On installation
1. Openings in the LCD monitor cabinet are provided for ventilation.
To prevent overheating, these openings should not be blocked or
covered. if you put the LCD monitor in a bookcase or some other
enclosed space, be sure to provide adequate ventilation.
2. Put your LCD monitor in a location with low humidity and a minimum
of dust.
3. Do not exepose the LCD monitor to rain or use it near water
(in kitchens, near swimming pools, etc.). if the LCD monitor
accidentally gets wet, unplug it and contact an authorized dealer
immediately.You can clean the LCD monitor with a damp cloth if
necessary, but be sure to unplug the LCD monitor first.
5. Locate your LCD monitor near an easily accessible AC outlet.
6. High temperature can cause problems. Don't use your LCD
monitor in direct sunlight and keep it away from heaters, stoves,
fireplaces, and sources of heat.
English - 5
CAUTION
Environmental Conditions for transport and Storage
- Temperature range within -20°C to 60°C
- Relative humidity range 10% to 85%
Atrnospheric pressure range within 500 to 1060hPa.
Intended Use
- This TFT-LCD Monitor is as accessory intended for use with
Medical Equipment to display alpha, numerical and graphical data.
This symbol alerts the user that important literature
concerning the operation of this unit has been included.
Therefore, it should be read carefully in order to avoid potential
problems.
This symbol warms user that un-insulated voltage within the
unit the may have sufficient magnitude to cause
electrical shock. Therefore, it is dangerous to make
contact with any part inside the unit. To reduce the risk of
electric shock, DO NOT remove cover (or back).
There are no user serviceable parts inside. Refer servicing to
qualified service personal.
To prevent fire or shock hazards, do not expose this unit to
rain or moisture. Also, do not use this unit's polarized plug
with an extension cord receptacle or other outlets unless the
prongs can be fully inserted. The display is designed to meet the
medical safety requirements for a patient vicinity device.
This device may not be used in connection with life support
equipment.
Underwriters Laboratories (UL) Classification:
UL safety Compliance:
This LCD monitor is U.L. Classified WITH RESPECT TO
ELECTRIC SHOCK, FIRE AND MECHANICAL
HAZARDS ONLY IN ACCORDANCE WITH UL 606011/CAN/CSA C22.2 NO. 601.1
6 - English
English - 7
EEC Safety Compliance:
This display unit meets the requirements of EN-60601-1 so as
to conform to the Medical Device Directive 93/42/EEC
(general safety information).
The monitor should be powered from a center tapped circuit when used
in the US at voltages over 120 volts. Monitor is intended for continuous
operation.(Using Plug for US: 120V rating -5-15P tYPE, 230V rating-615P type)
Recycling :
Follow local governing ordinances and recycling plans
regarding the recycling or disposal of this requirement.
Cleaning Instructions :
Follow your hospital protocol for the handling of blood and
body fluids. Clean the display with a diluted mixture of
mild detergent and water. Use a soft towel or swab.
Use of certain cleaning agnts may cause degrandation to
the labels and plastic components of the product.
Consult cleanser manufacturer to see if agent is compatible
with it. Do not allow liquid enter the display.
Servicing
Do not attempt to service the apparatus yourself as opening or
removing covers may expose you to dangerous voltages or other
hazards, and will void the warranty. Refer all servicing to qualified
service personnel.
Unplug the apparatus from its power source and refer servicing to
qualified personnel under the following conditions:
If the power cord or plug is damaged or frayed.
If liquid has been spilled into the apparatus.
If objects have fallen into the apparatus.
If the apparatus has been exposed to rain or moisture
If the apparatus has been subjected to excessive shock by being
dropped.
If the cabinet has been damaged.
If the apparatus seems to be overheated.
If the apparatus emits smoke or abnormal odor.
If the apparatus fails to operate in accordance with the operating
instructions.
Accessories
Use only accessories specified by the manufacturer, or sold with the
apparatus.
Classification
- Protection against electric shock : Class I
- Applied Parts : No Applied Parts
- Protection against harmful ingress of Eater : IPX0
- Degree of safety in the presence of flammable anesthetics mixture
with air or with oxygen or with nitrous oxide.
Not suitable for use in the presence of a flammable anesthetics
mixture with oxygen or with nitrous oxide.
- Mode of operation : Continuous.
8 - English
English - 9
FCC Information
This equipment has been tested and found to comply with the limits of a
Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
interference. This monitor can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, it may interfere
with other radio communications equipment. There is no guarantee that
interference will not occur in a particular installation.
If this equipment is found to cause harmful interference to radio or
television reception, the user is encouraged to try to correct the
interference by carrying out one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the distance between the color monitor and the subject
of interference.
3. Plug the monitor into a outlet on a different electrical circuit than
\that to which the subject of interference is connected.
4. Consult the dealer or an experienced radio/TV technician for help.
1. Guidance and manufacturer's declaration - electromagnetic emissions
The FS-L4202D is intended for use in the electromagnetic environment specified below.
The customer or the user of the FS-L2401D should assure that it is used in such an environment.
RF Emissions
CISPR 11
Group 1
RF Emissions
CISPR 11
Class B
Harmonic emisions
IEC 61000-3-2
Electromagnetic environment -guidance
Compliance
Emission test
The FS-L4202D uses RF energy only for its internal function.
Therefore, its RF emissions are very low and are not likely to
cause any interference in nearby electronic equipment
FS-L4202D is suitable for use in ail establishments, including
domestic establishments and those directly connected to the
public low-voltage power supply network that supplies buildings
used for domestic purposes
Voltage fluctuations
Complies
IEC 61000-3-3
NOTICES TO USER :
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may
cause undesired operation.
FCC WARNING :
This equipement geneates or uses radio frequency energy. Changes or
modifications to this equipement may cause harmful interference unless
the modifications are expressly approved in the instruction manual. The
user could lose authority to operate this equipment if an unauthorized
change or modification is made.
2. Guidance and manufacturer's declaration - electromagnetic immunity
FS-L4202D is intended for use in the electromagnetic environment specified below.
The customer or the user of FS-L4202D should assure that it is used in such an environment.
Immunity test
IEC 60601 Test level
Electrostatic
6kV Contact
6kV Contact
discharge(ESD)
8kV air
8kV air
Electrical fast
transient/burst
IEC 61000-4-4
Electromagnetic environment -guidance
Floors should be wood,concrete or
ceramic tile. If floors are covered with
synthetic material, the relative humidity
should be at least 30%
IEC61000-4-2
2kV for power supply 2kV for power supply Mains power quality should be that of a
lines
lines
typical commercial or hospital environment.
1kV for input/output
1kV for input/output
lines
10 - English
Complince level
lines
English - 11
Surge
1kV differential mode
IEC 61000-4-5
2kV common mode
1kV differential mode Mains power quality should be that of a
2kV common mode
typical commercial or hospital environment.
Immunity test
IEC 60601 Test level
Recommended separation distance
Portable and mobile RF communications
Conducted RF
IEC 61000-4-6
3 Vrms
3 Vrms
150 kHz to 80MHz
150 kHz to 80MHz
Electromagnetic environment -guidance
Complince level
80MHz to 800MHz
Portable and mobile RF communications
equipment should be used no closer to any
part of the FS-L4202D, including cables, than
80MHz to 2.5GHz
the recommended separation distance
calculated from the equation applicable to
the frequency of the transmitter.
Radiated RF
IEC 61000-4-3
Recommended separation distance
where P is the maximum output power rating of the transmitter in watts (W)
3. Guidance and manufacturer's declaration - electromagnetic immunity
3 V/m
3 V/m
where P is the maximum output power rating
80.0 MHz to 2.5 GHz 80.0 MHz to 2.5 GHz
of the transmitter in watts (W) according to
the transmitter manufacturer and d is the
recommended separation distance in meters
(m).
Field strengths from fixed RF transmitters, as
deter-mined by an electromagnetic site
survey, a should be less than the compliance
level in each frequency range.
FS-L4202D is intended for use in the electromagnetic environment specified below.
The customer or the user of FS-L4202D should assure that it is used in such an environment.
NOTE : U is the A.C. mains voltage prior to application of the test level.
Immunity test
Power frequency
(50/60Hz)
magnetic field
IEC 61000-4-8
Voltage dips,
short interruptions
and voltage
variations on
power supply
input lines
IEC 61000-4-11
12- English
IEC 60601 Test level
Complince level
3.0A/m
3.0A/m
<5 % U
(>95 % dip in U )
for 0.5 cycle
40 % U
(60 % dip in U )
for 5 cycle
70 % U
(30 % dip in U )
for 25 cycle
<5 % U¨‰
(<95 % dip in U¨‰ )
for 5 s
<5 % U
(>95 % dip in U )
for 0.5 cycle
40 % U
(60 % dip in U )
for 5 cycle
70 % U
(30 % dip in U )
for 25 cycle
<5 % U
(<95 % dip in U )
for 5 s
Electromagnetic environment -guidance
Power frequency magnetic fields should be
at levels characteristic of a typical location
in a typical commercial or hospital
environment.
Mains power quaility should
be that of a typical commercial or hospital
environment. If the user of FS-L4202D
requires continued operation during
power mains interruptions, it is
recommended that FS-L4202 be powered
from an uninterruptible power supply or a
battery
4. Recommended separation distances between portable and mobile
RF communications equipment and the FS-L4202D
- The is intended for use in an electromagnetic environment in which radiated RF
disturbances are controlled. The customer or the user of the FS-L4202D can help
- Prevent electromagnetic interference by maintaining a minimum distance between
portable and mobile
- RF communications equipment (transmitters) and the FS-L4202D as recommended
below,according to the maximum output power of the communications equipment.
Separation distance according to frequency of transmitter[m]
Rated
maximum output
power of tr
ansmitter [W]
150kHz to 80MHz
80MHz to 800MHz
800MHz to 2.5GHz
V1=3Vrms
E1=3V/m
E1=3V/m
English - 13
Parts
0.01
0.116
0.116
0.2333
0.1
0.368
0.3687
0.7378
1.166
1.1660
0.2333
10
3.687
3.6872
0.7375
100
11.660
11.6600
23.333
42" LCD Monitor
For transmitters rated at a maximum output power not listed above, the recommended separation distance d
in metres (m)can be estimated using the equation applicable to the frequency of the transmitter, where p is
the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1) At 80MHz and 800MHz, the separation distance for the higher frequency range applies.
NOTE 2) These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
Quick Startup
Powering On The Unit :
1. Connect the power supply to the display via the power plug.
2. Plug in the DC adapter to AC inlet with power cord cable.
3. Connect the video source to this monitor.
4. Apply power to the peripheral device.
5. Turn on the switch of this monitor.
Accessories
User Manual
BNC Cable
14- English
D-SUB Cable
S-Video (Y/C) Cable
DVI Cable
AC Power code
(Hospital Grade)
English - 15
Mechanical Product Drawing
Connector
Back Panel Jacks
300
600
AC ON/OFF SWITCH
S-VIDEO/Y
AC Inlet
S-VIDEO/C
OPTICAL IN
C-VIDEO
DVI IN
RED /Pr
DVI OUT
GREEN/Y
VGA IN
BLUE/Pb
RS232C
C-SYNC/H-SYNC
SDI IN
V-SYNC
6-M8(USER MUNT HOLE)
SDIOUT
16 - English
English - 17
Control
OSD Button Function
OSD Button Position
An 8 button keypad, located in button light corner on the front of the
display, allows the user to make adjustments to various display
parameters using the On Screen Display (OSD) system.
Power Indicating LED
Green : Normal mode
Amber: Standby mode
OFF : Monitor off
On-Screen Display (OSD) Function Button
POWER : Turns ON/OFF the monitor.
MENU : With OSD deactivated, Activated to OSD menu.
With OSD activated, Exit from main menu or sub menu.
PIP : With OSD deactivated, Hot key of PIP mode.
UP ( ) : With OSD deactivated, Hot key of the brightness
control and increases the brightness.
With OSD activated, move the cursor upward.
selected function.
DOWN ( ) : With OSD deactivated, Hot key of the brightness
control and decreases the brightness.
With OSD activated, move the cursor downward.
18 - English
English - 19
Power management
- (MINUS) : With OSD deactivated, Hot key of the contrast
control and decreases the contrast.
With OSD activated, decreases the adjustment of
the selected function.
+ (PLUS) : With OSD deactivated, Hot key of the contrast
control and increase the contrast.
With OSD activated, enter sub menu and increases
the adjustment of the selected function.
INPUT : Change the display signal source.
If D-SUB Analog's picture size not matched with full
screen size or image is noisy press the input buttom
during 2~3 seconds then you can see the most
appropriate screen.
20 - English
This monitor does not adhere to the VESA DPMS standard when no
signal is present on the video inputs.
Status
Normal Mode
Standby Mode
LED sign
Green on
Amber Blinking
Power Consumption
<260W
<20W
English - 21
Adjusting OSD
Color temp
COLOR TEMP
MODE
ADJUST
BRIGHTNESS
49
CONTRAST
50
SHARPNESS
50
SATURATION
50
COLOR
BACK LIGHT
100
EXIT
SELECT
CVIDEO
50
BLUE
50
RED
Red balance (Only Working with USER mode) (Range : 0~100)
SELECT
GREEN
Green balance (Only Working with USER mode) (Range : 0~100)
BLUE
Blue balance (Only Working with USER mode) (Range : 0~100)
MOVE
NTSC 60Hz/3.58MHz
CVIDEO
NTSC 60Hz/3.58MHz
BRIGHTNESS
49
CONTRAST
50
SHARPNESS
50
SATURATION
50
COLOR
BACK LIGHT
22 - English
MODE
Change the color model. (C1(Redish), C2(greenish). USER)
Image
ADJUST
CVIDEO
50
GREEN
MOVE
Adjust
EXIT
RED
EXIT
USER
100
SELECT
BRIGHTNESS
Increase or decrease the brightness. (Range : 0~100)
IMAGE
IMAGE SIZE
H POSITION
CLOCK
Increase or decrease the sampling frequency.(Range : 0~100)
EXIT
CVIDEO
NTSC 60Hz/3.58MHz
H POSITION
Adjust the horizontal position of the displayed source image.
(Range : 0~100)
V POSITION
Adjust the vertical position of the displayed source image.
(Range : 0~100)
50
FILTER
NORMAL
OVER SCAN
0 1 2 3 4 5 6 7 8
MODE 1
IMAGE SETTING
MOVE
IMAGE SIZE
Change the image size (Scaling mode)
(Full, Fill aspect, 1:1, Normal, Video, Zoom, video only)
50
V POSITION
CONTRAST
Increase or decrease the Contrast. (Range : 0~100)
FILL ASPECT
SELECT
MOVE
NTSC 60Hz/3.58MHz
PHASE
Increase or decrease the Phase level.(Range : 0~100)
BACK LIGHT
Increase or decrease the back light dimming level (Range : 0~100)
FILTER
Set the sharpness of image ( Softest, Soft, Normal, Sharp, Sharpest)
AUTO ADJUST
Fit to the most appropriate screen on the D-SUB Analog signal
OVER SCAN
Adjust the displayed size. (0~8)
SHARPNESS
Adjust the sharpness of the displayed image.
IMAGE SETTING
Allows selection of one of five user defined image presets.
SATURATION
Adjust the saturation of the image.
COLOR
Adjust the color of the image.
English - 23
Standard Signal table
PC Supported Mode
Setup
SETUP
LANGUAGE
ENGLISH
OSD COLOR
50
Resolution
Horizontal Frequency
(KHz)
Vertical Frequency
(Hz)
Clock Frequency
(MHz)
640 X 350 @70Hz
31.469
70.087
25.175
OSD COLOR
Adjust the OSD background from white opaque to half translucent.
720 X 400 @70Hz
31.469
70.082
28.324
640 X 480 @60Hz
31.469
59.940
25.175
OSD POSITION
Change the osd position. (9 Positions)
640 X 480 @75Hz
37.500
75.000
31.500
800 X 600 @60Hz
37.879
60.317
40.000
DURATION
Adjust time until the OSD Menu will disappear after adjusting the menu.
(5, 10, 20, 30, 60, 90, 120, 180, 240 seconds)
800 X 600 @75Hz
46.875
75.000
49.500
1024 X 768 @60Hz
48.363
60.004
65.000
1024 X 768 @75Hz
60.023
75.029
78.750
1152 X 864 @60Hz
54.348
60.053
80.000
1152 X 864 @75Hz
67.500
75.000
108.000
1280 X 1024@75Hz
79.976
75.025
135.000
1360 X 768@75Hz
47.649
59.936
84.625
1600 X 1200@60Hz
74.077
59.981
130.375
1920 X 1080@60Hz
67.500
60.000
148.500
LANGUAGE
Change the OSD language (8 language)
(Korean, English, French, Spanish, German, Chinese, Japanese, Italian)
OSD POSITION
20 SEC
DURATION
RESET SETTINGS
AUTO SOURCE SELECT ON
EXIT
SELECT
MOVE
CVIDEO
NTSC 60Hz/3.58MHz
RESET SETTINGS
Changes the all OSD value to factory out going status.
AUTO SOURCE SELECT
Disable of enable auto source select.
(ON: Searches through all possible input source untill an active video
source is found.
OFF: Video input is manually selected.)
PIP
PIP
LAYOUT
PIP
SOURCE
COMPONENT
SWAP
EXIT
CVIDEO
24 - English
SELECT
MOVE
LAYOUT
Change the OSD layout. (Single, PIP, PBP1, PBP2)
SOURCE
Change the secondary source.
SWAP
Swaps the position and size of the Primary and Secondary image.
SDI Video format
Output Signal
Description
SMPTE-274M
1080i (60 / 59.94 / 50)
1080p (30 /29.97 / 25 / 24 / 24sF / 23.98 / 23.98sF)
SMPTE-296M
720p (60 / 59.94 / 50)
SMPTE-260M
1035i (60 / 59.94)
SMPTE-125M
480i (59.94)
ITU-R BT.656
576i (50)
NTSC 60Hz/3.58MHz
English - 25
Signal connector Pin Assignments
VGA (15Pin D-Sub)
Pin No.
Assignment
Red
Green
Blue
Ground
DDC 5V Standby
Cable Connection check
Ground-Red
Ground-Green
Ground-Blue
Pin No.
10
11
12
13
14
15
Assignment
No Connection
Ground-Sync
Ground
DDC Data
H.Sync
V.Sync
DDC Clock
Pin No.
Assignment
T.M.D.S. Data2T.M.D.S. Data2+
T.M.D.S. Data2 Shield
No Connection
No Connection
DDC Clock
DDC Data
No Connection
Assignment
S-VIDEO/Y (Luma)
S-VIDEO/C (Chroma)
Ground
10
11
15
DVI In,Out (24Pin DVI-D)
Pin No.
S-Video (BNC)
RS232C (D-SUB 9Pin)
Pin No.
Assignment
13
No Connection
14
+5V Power
15
Cable Connection check
16
Hot Plug Detect
17
T.M.D.S. Data018
T.M.D.S. Data0+
19
T.M.D.S. Data0 Shield
20
No Connection
T.M.D.S. Data1-
21
No Connection
10
T.M.D.S. Data1+
22
T.M.D.S. Clock Shield
11
T.M.D.S. Data1 Shield
23
T.M.D.S. Clock+
12
No Connection
24
T.M.D.S. Clock-
16
17
24
Pin No.
Assignment
No Connection
TXD
RXD
No Connection
Ground
No Connection
No Connection
No Connection
No Connection
SDI (BNC)
C-Video (BNC)
Pin No.
26 - English
Assignment
Composite
Ground
Pin No.
Assignment
SDI IN
SDI OUT
Ground
English - 27
Specification
RGBHV/RGBS/YPbPr (BNC)
Model
Assignment
RGBS
Y Pb Pr
Pin No.
Red
Pr
Green
Blue
Pb
H-Sync / C-Sync No Connection
V-Sync
No Connection
Ground
R/Pr
G/Y
B/Pb
CS/HS
VS
LCD
Panel
Synchro
nization
OPTICAL
Pin No.
Assignment
OPICAL Clock
OPICAL Blue
OPICAL Green
OPICAL Red
FS-L4202D
Type
TFT-LCD
Screen Size
42 linch
Maximum Resolution
1920 X 1080 @ 60Hz
Pixel pitch
0.4845(H) mm X 0.4845(V) mm
Display Colors
16.7M
Contrast Ratio
1000:1
Viewing Angle
89° / 89° / 89° / 89°
Response Time
10msec(Rising+Falling)
Luminance
500cd/m
Horizontal Frequency
30KHz~75KHz
Vertical Frequency
50Hz~75Hz
Maximum
Power
Consumption Standby Mode
260W
Control key
Front side
INPUT, -, +,
Input
Signal
Video
2XBNC (SVHS Y/C), 1XBNC (SDI), 5XBNC
Out
Signal
Under 20W
, PIP, MENU, POWER
1XDVI, 1XOptical DVI, 1XD-SUB, 1XBNC (CVBS)
(Component Y/G, Pb/B, Pr/R, H/CS, VS Input)
Video
1XDVI, 1XBNC (SDI)
Input power AC 100-230V~, 50-60Hz, 3A Max
Dimension
28 - English
Size and Weight
1024.6 617.4 111.1(mm)/ 29Kg
English - 29

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2007:08:06 22:01:44Z
Modify Date                     : 2007:08:06 22:04:41+09:00
Page Count                      : 16
Has XFA                         : No
Creation Date                   : 2007:08:06 22:01:44Z
Producer                        : Acrobat Distiller 4.0.5  for Macintosh
Author                          : ¼ö
Mod Date                        : 2007:08:06 22:04:41+09:00
Metadata Date                   : 2007:08:06 22:04:41+09:00
Creator                         : ¼ö
Title                           : FS-L4202D_Manual finally
EXIF Metadata provided by EXIF.tools
FCC ID Filing: THCFS-L4202D

Navigation menu