DSP Group DHANJ DECT Module User Manual DHX91 DHAN Module Datasheet

DSP Group Ltd DECT Module DHX91 DHAN Module Datasheet

Users Manual

Download: DSP Group DHANJ DECT Module User Manual DHX91 DHAN Module Datasheet
Mirror Download [FCC.gov]DSP Group DHANJ DECT Module User Manual DHX91 DHAN Module Datasheet
Document ID3853624
Application IDbwjkxZJrycr+rxBo8r6sIQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize96.85kB (1210686 bits)
Date Submitted2018-05-17 00:00:00
Date Available2018-05-18 00:00:00
Creation Date2018-03-13 11:27:33
Producing SoftwareMicrosoft® Word 2016
Document Lastmod2018-05-15 17:28:52
Document TitleDHX91 DHAN Module Datasheet
Document CreatorMicrosoft® Word 2016
Document Author: Rochelle Singer

DHAN-J Module
DECT-ULE Platform
Datasheet
Version: 2.2
March 13 2018
Version 2.1
DHAN-J Module
Headquarters
USA
DSP Group Inc.
161 S San Antonio Rd
Suite 10
Los Altos, CA 94022
Tel: (408)986-4300
Fax:(408)986-4323
APAC
China
DSP Group (HK) Limited
Unit 1-4, 11/F,
909 Cheung Sha Wan Rd.
Kowloon
Hong Kong
Tel: +852-(3965)-5888
Israel
DSP Group Ltd.
5 Shenkar Street
Herzelia, Israel 4672505
Tel: 972-9-952-9696
Fax: 972-9-954-1234
DSP Group (Shenzhen) Limited
Room 1819, 18/F
Kerry Centre, Renminnan Road,
Shenzhen, China 518001
Tel: +(86 755) 2518 1214
Europe
Germany
DSPG Technologies GmbH
Nelson-Mandela-Platz 18
90459 Nurnberg
Tel: +49-911-2001-0
Fax: +49-911-2001-1210
Scotland
DSPG Edinburgh Ltd.
Geddes House
Kirkton North
Livingston EH54 6GU
Tel: +44-1223-772200
Ascend Technology Inc.
Room 1303,
New World Center,
No.6009 Yitian Road,
Futian District,
Shenzhen City, China
Tel: +86-755-820-24598
Fax: +86-755-239-82986
Ascend Technology Inc.
Rm 607,
Hui Huang International Center,
1st Place, Shangdi 10th Road,
Haidian District, Beijing City, P.R.
Worldwide Sites
Japan
DSP Group (Japan) Inc.
1-29-1 Nishi-Gotanda
Shinagawa-Ku Tokyo 141-0031
Tel:+81-(3)-3493-3050
Tomen Electronics
8-27, Kohnan 1 Chome,
Minato-ku, Tokyo
108-8510, Japan
Tel: +81-(3)-5462-9619
Fax: +81-(3)-5462-9686
Korea
Daesung Semiconductors
140-848, RM 401
Wonhyo BD. 46-1
Wonhyo-ro 3ka, Yongsan-gu,
Seoul, Korea
Tel: +82-(2)-3272-7300
Fax: +82-(2)-712-4632-3
India
DSP Technology Indian Private
Limited
Information Technology Park
Nagawara Village Kasaba Hobli
Bangalore 560045
Tel: +91 80 4024 8399
Taiwan
Ascendtek Electronics, Inc
11F-7, No. 77, Sec. 1
Hsin Tai Wu Rd.,
Hsi Chih
Taipei Hsien,
Taiwan, R.O.C
Tel: 886-2-2698-8696
Fax: 886-2-8698-2138
This document is provided by DSP Group, Inc. and/or one or more of its subsidiaries (“DSP Group”). All information and data contained
in this document is for informational purposes only, without any commitment on the part of DSP Group, and is not to be considered as an
offer for a contract. DSP Group shall not be liable, in any event, for any claims for damages or any other remedy in any jurisdiction
whatsoever, whether in an action in contract, tort (including negligence and strict liability) or any other theory of liability, whether in law
or equity including, without limitation, claims for damages or any other remedy in whatever jurisdiction, and shall not assume responsibility
for patent infringements or other rights to third parties, arising out of or in connection with this document. Further, DSP Group reserves
the right to revise this publication and to make changes to its content, at any time, without obligation to notify any person or entity of such
revision changes. These materials are copyrighted and any unauthorized use of these materials may violate copyright, trademark, and other
laws. Therefore, no part of this publication may be reproduced, photocopied, stored on a retrieval system, or transmitted without the express
written consent of DSP Group. Any new issue of this document invalidates previous issues.
DSP Group reserves the right to revise this publication and to make changes to its content, at any time, without obligation to notify any
person or entity of such revision changes.
© 2018 DSP Group Confidential. All rights reserved.
March 2018
DSP Group Confidential
2/19
Version 2.1
DHAN-J Module
Table of Contents
TABLE OF CONTENTS
1.
INTRODUCTION ........................................................................................................................................... 4
General Description ............................................................................................................................................ 4
Features ............................................................................................................................................................... 4
Block Diagram .................................................................................................................................................... 4
2.
PIN AND SIGNAL DESCRIPTION............................................................................................................... 5
3.
MODULE ELECTRICAL SPECIFICATIONS .............................................................................................. 7
Absolute Maximum Rating ................................................................................................................................. 7
Recommended Operating Conditions ................................................................................................................. 7
Peak Currents and Hibernation Current .............................................................................................................. 7
Transmitter .......................................................................................................................................................... 8
Receiver .............................................................................................................................................................. 8
4.
REFERENCE SCHEMATIC .......................................................................................................................... 9
Module and External Host Interface ................................................................................................................... 9
Power Supply and Optional JTAG ...................................................................................................................... 9
Optional Audio and 32KHz XTAL ................................................................................................................... 10
Interfacing to an external ASIC Sensor or Actuator ......................................................................................... 10
Notes to schematic: ........................................................................................................................................... 11
5.
INTERFACING THE DHAN-J WITH AN EXTERNAL MCU .................................................................. 12
RSTN Input ....................................................................................................................................................... 12
Wake Up Input .................................................................................................................................................. 12
Wake Up Output ............................................................................................................................................... 12
6.
APPLICATION PCB DESIGN RECOMMENDATIONS............................................................................ 13
7.
ASSEMBLY INFORMATION ..................................................................................................................... 14
Mechanical Drawing ......................................................................................................................................... 14
PCB Metal Land Pattern Recommendation ...................................................................................................... 15
PCB Solder Mask Recommendation ................................................................................................................. 16
PCB Stencil Pattern Recommendation .............................................................................................................. 16
Pick & Place, Reflow ........................................................................................................................................ 16
8.
SUPPLEMENTARY INFORMATION ........................................................................................................ 17
Labeling (appended to the module shield) ........................................................................................................ 17
Handling Guidance ........................................................................................................................................... 17
RF Exposure Information and Statement .......................................................................................................... 17
FCC & IC Interference Statement ..................................................................................................................... 18
Declaration of Conformance (DOC) ................................................................................................................. 18
IPEI and EMC ................................................................................................................................................... 18
Ordering Information ........................................................................................................................................ 19
Change Log ....................................................................................................................................................... 19
February 27, 2018
DSP Group Confidential
3/19
Version 2.1
DHAN-J Module
Introduction
1. Introduction
General Description
The DSPG DHAN-J module is based on the state-of-the-art DHX91 - a 3rd generation DECT SOC. The DHAN-J
module is suited for a DECT-ULE Device (or Node) applications. The DHAN-J SW stack includes standard
DECT-ULE MAC-PHY connectivity as well as HAN-FUN (= the ULE Alliance Standard) functionality for DualMode (data and audio) ULE. The Application SW written by the customer can leverage the DHX91 within the
DHAN-J or, alternatively, the application Host can run on external MCU which communicates with the DHAN-J
via a UART interface. The API presented by the DHAN-J is called CMND and DSP Group can supply reference
code for accessing the ULE connectivity presented at this interface.
Features

Excellent radio performance, with over 123dB system gain

A printed antenna is included in the module

Radio covers all regional DECT bands. A simple re-configuration of the EEPROM is required

Radio is fully compliant with ETSI DECT and ULE standards. Regulatory (EU, FCC) certification is
pending

Compact module footprint of 27.2x15.2x3.3 (including the RF shield height)

Minimized external BOM

Operating Temperature spanning -40ºC to 85ºC
Block Diagram
DHAN-J
QSPI
DHX91
13.824M
RF
Matching
/Filter
I2C, UART, SPI, JTAG
32.768K
DHAN-J Module Block Diagram
March 2018
DSP Group Confidential
4/19
DHAN-J Module
Version 2.1
Pin and Signal Description
2. Pin and Signal Description
PIN NO.
NAME
GND
GND
ANT2
Test Pin. Leave Unconnected
DCINS
Leave as not connected (NC)
DCIN3
ADC input used to monitor power supply input
RSTN
For application running on an external MCU, this pin
should be connected to a MCU IO and used to reset
the DHAN-J
SCL (GPIO0)
GPIO or I2C Clock. Open Drain, reset value is
floating. Leave as not connected if not used
SDA (GPIO1)
GPIO or I2C Data. Open Drain, reset value is
floating. Leave as not connected if not used
IIC_ACK (GPI03)
GPIO7
GPIO or SPI Data In. Leave as not connected if not
used
10
GPIO8
GPIO or SPI Data Out. Leave as not connected if not
used
11
RxD (GPIO9)
GPIO or UART Rx (most typically) or SPICLK. See
12
TDI
JTAG Data In. Should be connected to TP (see
Application Schematic Section below)
13
TMS
JTAG Mode Select. Should be connected to TP
14
TDO
JTAG Data Out. Should be connected to TP
15
TCK
JTAG Clock. Should be connected to TP
16
RTCK
JTAG Reset. Should be connected to TP
17
GND
GND
18
TxD (GPIO10)
19-20
GND
21
VBAT
22
DOUBCAP2P
23
DCIN2
Leave Unconnected
24
VCC3V
3V (Doubler) Output. While DHAN-J is hibernating,
this pin is either in tristate (default SW
configuration) or pulled to GND. Can be used in
conjunction with GPIO7&8 above to drive an LED
or button during non-hibernation modes
25
LEDSINK/DCIN1
26
GND
February 27, 2018
DESCRIPTION/TYPE
GPIO or I2C ACK. Leave as not connected if not
used
GPIO or UART Tx or SPICS
Power Supply Input. Connect to Battery or regulated
supply
Pull down with 1M resistor
ULE I/O. If not used, can be left NC
GND
DSP Group Confidential
5/19
DHAN-J Module
Version 2.1
Pin and Signal Description
PIN NO.
NAME
27
AMP2_OUT
28
AMP1_P
29
AMP1_OUT
30
MPWR/ANA2_IN
31
MIN
If not used, can be left as NC
32
MIP
If not used, can be left as NC
33
ANA_IN1
ULE I/O. If not used, can be left NC
34
SPOUTP
If not used, can be left as NC
35
SPOUTN
If not used, can be left as NC
36
PWM0
37
XIN_32K
Connect to 32.768 XTAL if required – see
application schematic notes
38
XOUT_32K
Connect to 32.768 XTAL if required – see
application schematic notes
39
VDD_ULE
1.8V test point. Active during hibernate. Leave NC
40
VBATRF
41-42
GND
February 27, 2018
DESCRIPTION/TYPE
ULE I/O. Typically used (as input) to wake up the
DHAN-J from hibernation
ULE non-inverting sensor conditioning input
ULE I/O. Typically used (as output) to indicate
DHAN-J is active (logic high)
ULE I/O (or Microphone Power). During hibernate,
Logic High should not be applied to this pin (it can
result in leakage current). If not used, can be left NC
Analog Output
Power Supply Input to RF
GND
DSP Group Confidential
6/19
Version 2.1
DHAN-J Module
Module Electrical Specifications
3. Module Electrical Specifications
All parameters are for 25ºC.
Absolute Maximum Rating
Table 3-1: Absolute Maximum Ratings
Minimum Voltage Applied to all pins: -0.3V
Maximum Voltage Applied to all pins: +4.6V
Storage Temperature Range: -45 to 90ºC
Note: Functionality at or above these limits is not implied. Exposure to absolute maximum ratings for
extended periods may affect device reliability.
Recommended Operating Conditions
Table 3-2: Recommended Operating Conditions
RATING
MIN
TYP
MAX
UNIT
Operating ambient
temperature
-40
+25
+85
°C
VBAT, VBATRF
1.95
3.0
3.6
0.8
All GPIOs
(VCC is at nominal
3V)
CONDITIONS
VIL
VIH
VOL
VOH
2.0
0.4
2.4
1.95
DCIN3
3.0
VBAT
Peak Currents and Hibernation Current
VBAT=VBATRF = 3V
PARAMETER
TEST CONDITIONS
TYP
MAX
UNIT
Tx Current
Band=EU @ 23dBm
400
480
mA
Tx Current
Band=US @ 21 dBm
250
300
mA
Rx Current
Max Gain Setting
125
135
mA
Hibernation
Current
February 27, 2018
DSP Group Confidential
µA
7/19
Version 2.1
DHAN-J Module
Module Electrical Specifications
Transmitter
VBAT=VBATRF = 3V
Table 3-3: Tx Characteristics
CHARACTERISTICS
TEST CONDITIONS
MIN
TYP
MAX
UNIT
NTP
Band=EU
21.5
23
24
dBm
NTP
Band=US
19
20
21
dBm
Harmonics
Band=EU & US
-40
-35
dBm
Transmission Mask
EN 301406
Paragraph 5.3.3
Comply
Frequency Offset
EN 301406
Paragraph 5.3.1
-50
+50
KHz
Frequency Drift
EN 301406
Paragraph 5.3.5
-15
+15
KHz/Slot
Emission Due
Modulation
EN 301406
Paragraph 5.3.6.2
M±1
M±2
M±3
M>±3
N/A
dBm
-20
-42
-47
-50
-8
-30
-40
-44
Receiver
VBAT=VBATRF = 3V
Table 3-4: Rx Characteristics
CHARACTERISTICS
TEST CONDITIONS
Sensitivity, BER <
1000ppm
EU Band
Maximum input power
EU Band
February 27, 2018
MIN
DSP Group Confidential
TYP
MAX
UNIT
-96
-93
dBm
15
dBm
8/19
Version 2.1
DHAN-J Module
Supplementary Info
4. Reference Schematic
Module and External Host Interface
Power Supply and Optional JTAG
February 27, 2018
DSP Group Confidential
9/19
Version 2.1
DHAN-J Module
Supplementary Info
Optional Audio and 32KHz XTAL
Interfacing to an external ASIC Sensor or Actuator
February 27, 2018
DSP Group Confidential
10/19
Version 2.1
DHAN-J Module
Supplementary Info
Notes to schematic:
a) For standalone DHAN-J applications, the external MCU can be removed
b) 20-pin JTAG connector is optional. It is recommended for those developing applications on the
DHAN-J (DHX91) where debug and reprogramming of the SW image is a must. For applications
running on an external MCU, the image on the DHAN-J as shipped should suffice
c) Audio interface is required for dual-mode ULE applications only
d) Sensor interface (I2C or otherwise) is relevant when the application host runs on the DHAN-J.
With the application host runs on an external MCU, sensors or actuators should interface with it
and DHAN-J should be used for wireless connectivity only
e) 32KHz XTAL is required for ULE Devices which need to respond to incoming paging from the
Hub with low-latency (within seconds or 10’s of seconds)
February 27, 2018
DSP Group Confidential
11/19
Version 2.1
DHAN-J Module
Supplementary Info
5. Interfacing the DHAN-J with an external MCU
RSTN Input
At power-up, the Application Host on the external MCU should hold this pin at logic Low until it is ready to
establish communication (via UART) with the DHAN-J. When ready, the App Host should apply a rising edge
(and leave at Logic High) and wait for the “Hello” indication from the DHAN-J. If at some point later on the MCU
cannot communicate with the DHAN-J, it should apply a low going pulse of >100uS to reset the DHX91 on the
DHAN-J.
Wake Up Input
Wake up the DHAN-J (from hibernation) by applying a positive going edge to AMP2_OUT (Pin27). The DHAN-J
will reply at the (UART) CMND API with a “Hello_Ind”. At that point the wakeup signal can be lowered.
Wake Up Output
In applications where the Device can be paged by the Hub, the external MCU can enter hibernation. When paged,
the DHAN-J will inform the external MCU via UART. If needed, the DHAN-J can wake up the external MCU by
applying a rising edge from ANA_IN1 (Pin33)
February 27, 2018
DSP Group Confidential
12/19
Version 2.1
DHAN-J Module
Supplementary Info
6. Application PCB Design Recommendations
It is recommended that unused pads on the Application PCB not be left as isolated islands of copper but rather
be anchored with via to inner layers of the PCB. It is also recommend that GND vias be applied liberally in the
vicinity of GND pins 25,26 and 28.
The following layout recommendations need to be apply on Main Board:
1.
Implement a solid ground under the DHAN-J module
2.
Do not route signal traces under the module. Use the bottom layer for signal routing
3.
Locate the antenna on the edge of the PCB – as pictured below
February 27, 2018
DSP Group Confidential
13/19
Version 2.1
DHAN-J Module
Supplementary Info
7. Assembly Information
An electronic version of the information in this Section can be downloaded from the DSP Group website, in the HW
Developer's Collateral section.
Mechanical Drawing
February 27, 2018
DSP Group Confidential
14/19
Version 2.1
DHAN-J Module
Supplementary Info
PCB Metal Land Pattern Recommendation
Zoom-In on the Pads
February 27, 2018
DSP Group Confidential
15/19
Version 2.1
DHAN-J Module
Supplementary Info
PCB Solder Mask Recommendation
PCB Stencil Pattern Recommendation
Pick & Place, Reflow
The DHAN-J module uses a flat shield cover to facilitate a fully automatic assembly process. For backing and
reflow recommendations, use MSL 3 in the JEDEC/IPC standard J-STD-20b. The temperature classification
(TC) for the module is 245° C.
February 27, 2018
DSP Group Confidential
16/19
Version 2.1
DHAN-J Module
Supplementary Info
8. Supplementary Information
Labeling (appended to the module shield)
1)
2)
3)
4)
5)
Year
Week
6-digit serial#
HW Version
SW Version
Handling Guidance
This module includes highly sensitive electronic circuity. Handling without proper ESD protection may damage the
module permanently.
February 27, 2018
DSP Group Confidential
17/19
Version 2.1
DHAN-J Module
Supplementary Info
FCC & IC Interference Statement
This device complies with part 15 of the FCC rules and RSS-213 of Industry Canada. Operation is subject to
the following two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de
brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized
modifications to this equipment. Such modifications could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help
- This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or
transmitter
Declaration of Conformance (DOC)
The full text of the EU Declaration of Conformity is available at the following internet address:
www.dspg.com.hk
IPEI and EMC
Each DHAN-J Module is shipped to the customer with a unique IPEI – its DECT identity.
DHAN-J will ship with an “EMC” of 0xFEB. This is the DSP Group “generic” EMC. The EMC setting identifies a
Device as belonging to a specific group of ULE Devices/Hubs that utilize some proprietary signaling.
In either case, the customer is free to re-program these parameters.
February 27, 2018
DSP Group Confidential
18/19
Version 2.1
DHAN-J Module
Supplementary Info
Ordering Information
Part #: DHX91MDMCFCE7AMI
Change Log
Table 8-1: List of Changes
REVISION
DATE
1.0
June 7, 2017
Baseline release
2.0
February 8,
2018
* Add ESD warning
* Add FCC declarations
2.1
February 27,
2018
* Add reference to the EU Declaration of Conformance
* Modify label on shield with FCC/IC/CE info
February 27, 2018
DESCRIPTION
DSP Group Confidential
19/19
ORIGINAL EQUIPMENT MANUFACTURER (OEM) NOTES

The OEM must certify the final end product to comply with unintentional radiators (FCC Sections 15.107 and
15.109) before declaring compliance of the final product to Part 15 of the FCC rules and regulations. Integration
into devices that are directly or indirectly connected to AC lines must add with Class II Permissive Change.

The OEM must comply with the FCC labeling requirements. If the module’s label is not visible when installed,
then an additional permanent label must be applied on the outside of the finished product which states:
“Contains transmitter module FCC ID: 2AOUK-DHANJ Additionally, the following statement should be included
on the label and in the final product’s user manual: “This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful interferences, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.”

The module is limited to installation in mobile or fixed applications. Separate approval is required for all other
operating configurations, including portable configuration with respect to Part 2.1093 and different antenna
configurations.

A module or modules can only be used without additional authorizations if they have been tested and granted
under the same intended end‐use operational conditions, including simultaneous transmission operations.
When they have not been tested and granted in this manner, additional testing and/or FCC application filing
may be required. The most straightforward approach to address additional testing conditions is to have the
grantee responsible for the certification of at least one of the modules submit a permissive change application.
When having a module grantee file a permissive change is not practical or feasible, the following guidance
provides some additional options for host manufacturers. Integrations using modules where additional testing
and/or FCC application filing(s) may be required are: (A) a module used in devices requiring additional RF
exposure compliance information (e.g., MPE evaluation or SAR testing); (B) limited and/or split modules not
meeting all of the module requirements; and (C) simultaneous transmissions for independent collocated
transmitters not previously granted together.
This Module is full modular approval, it is limited to OEM installation ONLY.
Integration into devices that are directly or indirectly connected to AC lines must add with Class II Permissive Change.
(OEM) Integrator has to assure compliance of the entire end product incluld the integrated Module.
Additional measurements (15B) and/or equipment authorizations (e.g Verification) may need to be addressed
depending on co-location or simultaneous transmission issues if applicable.
(OEM) Integrator is reminded to assure that these installation instructions will not be made available to the end user
of the final host device.
IC labeling requirement for the final end product:
The final end product must be labeled in a visible area with the following “Contains IC: 23573-DHANJ”
The Host Marketing Name (HMN) must be indicated at any location on the exterior of the host product
or product packaging or product literature, which shall be available with the host product or online.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance of 20 cm
between the radiator and your body.
This equipment complies with IC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance of 20 cm
between the radiator and your body.
Cet équipement est conforme aux limites d’exposition aux rayonnements de la IC établies pour un
environnement non contrôé. Cet équipement doit être installé et fonctionner à au moins 20 cm de
distance d’un radiateur ou de votre corps.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Warning                         : Invalid secondary xref table
Has XFA                         : No
Language                        : en-US
Tagged PDF                      : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : Rochelle Singer
Description                     : Table of Contents
Title                           : DHX91 DHAN Module Datasheet
Create Date                     : 2018:03:13 11:27:33+08:00
Creator Tool                    : Microsoft® Word 2016
Modify Date                     : 2018:05:15 17:28:52+08:00
Metadata Date                   : 2018:05:15 17:28:52+08:00
Producer                        : Microsoft® Word 2016
Document ID                     : uuid:eb30bcf4-b8b0-4d3c-827f-558108ff4545
Instance ID                     : uuid:61ca77ea-df47-4406-a8fd-b2bfd056ad08
Page Count                      : 21
Author                          : Rochelle Singer
Keywords                        : List, of, Figures
Subject                         : Table of Contents
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AOUK-DHANJ

Navigation menu