Deister Electronic TPU4030 RFID Transponder User Manual m en tpu 4030 pcb pro v111115 de bf

Deister Electronic GmbH RFID Transponder m en tpu 4030 pcb pro v111115 de bf

User Manual

Art. #TBA m_en_tpu-4030-pcb_pro_v111115_de_bfTPU 4030 PCBUser Manual
Content1. Technical Data............................................................52. Mechanical Dimensions..............................................63. General Information...................................................64. Activating the Transponder........................................75. Acoustic Signal............................................................76. Battery Monitoring......................................................72m_en_tpu-4030-pcb_pro_v111115_de_bf
Regulatory Notices EuropeHereby, deister electronic GmbH declares that this equipment - if used according to the instructions - is in compliance with the essential requirements and other relevant provisions of the RTTE Directive 1999/5/EC.A full declaration of conformity can be requested at:info@deister-gmbh.deApproved for use in all European countries.FCC WarningThis device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.CAUTION: Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate this equipment.Industry CanadaThis Class A digital apparatus complies with Canadian ICES-003.Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et  (2)  l'utilisateur de  l'appareil  doit accepter  tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.Note:When  installing  the  board  into  other  devices,  under  no  circumstances should an electrical connection be established. m_en_tpu-4030-pcb_pro_v111115_de_bf 3
© Copyright 2011 by deister electronic GmbHDisclaimerdeister electronic GmbH is not able to supervise the observance of the instructions given in this manual  as  well  as  the  conditions  and  methods  used  during  installation,  operation  and maintenance  of  the electronic  devices  and  components  respectively.  Therefore  we  disclaim liability  and  reject  responsibility  for  any  losses,  damages  or  costs  that  are  caused  by misapplication, installation, handling errors or faulty operation or related to the above in any other way. All our products are subject to current advancement, therefore we reserve the right for modifications without prior notice.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of deister electronic GmbH.deister  electronic  GmbH  reserves  the  right  to  make  changes  to  any  and  all  parts  of  this documentation without obligation to notify any person or entity of such changes.deister electronic GmbHHermann-Bahlsen Str. 1130890 BarsinghausenGermanyPhone: +49 (0) 51 05 - 51 61 11Fax: +49 (0) 51 05 - 51 62 17E-Mail: info.de@deister.comWeb: www.deister.com4m_en_tpu-4030-pcb_pro_v111115_de_bf
1. Technical DataDimensions:mm (inch) W x H x D 31.8 x 54.4 x 10 (1.25 x 2.14 x 0.41)Operating Temperature:°C (°F) 5 ... 50 (41 ... 122)Relative Humidity: 5 %...95 %, non-condensingPower Requirement: 1x CR 2450Frequency: 8 kHz, 125 kHz, 433 MHz  Reading Distance:in m (ft.) up to 10 (32.8)OTP: (e.g.  Formats up to 64 Bit)Fixcode: (e.g. 32 Bit)Conformity: EN 50364EN 301489Air interface (EU) EN 300330Air interface (US) FCC Part 15m_en_tpu-4030-pcb_pro_v111115_de_bf 5
2. Mechanical DimensionsAll dimensions in mm [inch].3. General InformationTPU 4030 is an active transponder, which was developed to be used in combination with Amantag Compact and / or PRX5 reader or ADA (Amantag deactivator).The transponder has three interfaces for communication with readers.•Receiving via 8,1 kHz •Sending via 433 MHz •Sending and receiving via125 kHz (passive modulation) Amantag Compact readers are using  8.1 kHz and  433 MHz  frequencies. These low-frequency fields are generated by the reader and serve to activate the transponder and to communicate with the transponder. Messages from  the transponder  to the reader are transmitted via 433  MHz.  Once a  transponder is brought into the sphere of the  low frequecy field, it is activated and gets recorded by the reader. Reader and transponder will remain in a constant communication with each other until the transponder leaves the field. The transponder can also send out an acoustic signal when it is detected by the reader.An 125 kHz interface is used for data exchange with PRX 5 reader or ADA. After activation, the transponder sends data to the reader for about 3 seconds. To activate the transponder again, it must first be removed from the reader field and then brought in again.6m_en_tpu-4030-pcb_pro_v111115_de_bf
4. Activating the TransponderFor transportation, the transponders are set to transport mode. Before use. they must be activated. The activation is done by an Amantag compact reader. The DIP switch B6 needs to be set to ON position.Attention!Possibly, the field strength must be increased. Therefore, set DIP switch B1 to B4 to “ON” position. After configuration, the transponder should be placed close to the reader  (it requires high power to wake up the transponder from transport mode). As long as the switch B6 is in ON position, there is no reaction from the reader to the transponder. Whether a transponder is active can only be revealed when the switch B6 is in OFF position.This way, several transponders are activated simultaneously. After activation, the switches must all be brought back into starting position.Attention!Once activated, transponders can not be switched into transport mode again.5. Acoustic SignalThe TPU 4030 has a built-in beeper, which can be activated by an Amantag compact reader. The acoustic signal is triggered by an Amantag compact reader whenever its door number is greater than seven.The picture below shows the switches A5 - A8 set to door number 9.Attention!Once  activated,  the  alarm  can  only  be  disabled  by  an  ADA  unit  (article  number: 0723.000). Otherwise, the transponder will beep, until the battery is empty.6. Battery MonitoringThe  battery  status  of  the  PrisonTag  can be  monitored.  An  ADA  unit  (article  number: 0723.000) can read and display the current battery status. For more information, please refer to the description of the ADA unit.m_en_tpu-4030-pcb_pro_v111115_de_bf 7
Art. #TBA m_en_tpu-4030-pcb_pro_v111115_de_bfHeadquartersGermany:deister electronic GmbHHermann-Bahlsen Str. 1130890 BarsinghausenTel.: +49 (0) 51 05 - 51 61 11Fax: +49 (0) 51 05 - 51 62 17info.de@deister.comwww.deister.comJapan:deister electronic Japan, LTD.Toshiba Hoshikawa Bldg. 4F2-4 Kawabe-chôHodogaya-ku, Yokohama-shi Kanagawa, 240-0001Tel.:  +81 (0) 45 340 1831Fax:  +81 (0) 45 340 1801info.jp@deister.comAmericas and Caribbean:Deister Electronics USA, Inc.9303 Grant AvenueManassas, VA 20110Tel.: +1 703 - 368 2739Fax: +1 703 - 368 9791info.us@deister.comFrance:deister electronic france101 rue Pierre Semard92320 ChatillonTel.: +33 (0) 1 47 - 35 78 78Fax:  +33 (0) 1 47 - 35 92 59info.fr@deister.comGreat Britain:deister electronic (UK) Ltd.Stapleton Way, Enterprise Park Spalding, LincolnshirePE11 3YQTel.: +44 (0) 1775 - 717100Fax: +44 (0) 1775 - 717101info.uk@deister.com

Navigation menu