Deister Electronic TPU4030 RFID Transponder User Manual m en tpu 4030 pcb pro v111115 de bf
Deister Electronic GmbH RFID Transponder m en tpu 4030 pcb pro v111115 de bf
User Manual
TPU 4030 PCB User Manual Art. #TBA m_en_tpu-4030-pcb_pro_v111115_de_bf Content 1. Technical Data............................................................5 2. Mechanical Dimensions..............................................6 3. General Information...................................................6 4. Activating the Transponder........................................7 5. Acoustic Signal............................................................7 6. Battery Monitoring......................................................7 m_en_tpu-4030-pcb_pro_v111115_de_bf Regulatory Notices Europe Hereby, deister electronic GmbH declares that this equipment - if used according to the instructions - is in compliance with the essential requirements and other relevant provisions of the RTTE Directive 1999/5/EC. A full declaration of conformity can be requested at: info@deister-gmbh.de Approved for use in all European countries. FCC Warning This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate this equipment. Industry Canada This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Note: When installing the board into other devices, under no circumstances should an electrical connection be established. m_en_tpu-4030-pcb_pro_v111115_de_bf © Copyright 2011 by deister electronic GmbH Disclaimer deister electronic GmbH is not able to supervise the observance of the instructions given in this manual as well as the conditions and methods used during installation, operation and maintenance of the electronic devices and components respectively. Therefore we disclaim liability and reject responsibility for any losses, damages or costs that are caused by misapplication, installation, handling errors or faulty operation or related to the above in any other way. All our products are subject to current advancement, therefore we reserve the right for modifications without prior notice. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of deister electronic GmbH. deister electronic GmbH reserves the right to make changes to any and all parts of this documentation without obligation to notify any person or entity of such changes. deister electronic GmbH Hermann-Bahlsen Str. 11 30890 Barsinghausen Germany Phone: +49 (0) 51 05 - 51 61 11 Fax: +49 (0) 51 05 - 51 62 17 E-Mail: info.de@deister.com Web: www.deister.com m_en_tpu-4030-pcb_pro_v111115_de_bf 1. Technical Data Dimensions: mm (inch) W x H x D 31.8 x 54.4 x 10 (1.25 x 2.14 x 0.41) Operating Temperature: °C (°F) 5 ... 50 (41 ... 122) Relative Humidity: 5 %...95 %, non-condensing Power Requirement: 1x CR 2450 Frequency: 8 kHz, 125 kHz, 433 MHz Reading Distance: in m (ft.) up to 10 (32.8) OTP: (e.g. Formats up to 64 Bit) Fixcode: (e.g. 32 Bit) Conformity: EN 50364 EN 301489 EN 300330 FCC Part 15 Air interface (EU) Air interface (US) m_en_tpu-4030-pcb_pro_v111115_de_bf 2. Mechanical Dimensions All dimensions in mm [inch]. 3. General Information TPU 4030 is an active transponder, which was developed to be used in combination with Amantag Compact and / or PRX5 reader or ADA (Amantag deactivator). The transponder has three interfaces for communication with readers. • • • Receiving via 8,1 kHz Sending via 433 MHz Sending and receiving via125 kHz (passive modulation) Amantag Compact readers are using 8.1 kHz and 433 MHz frequencies. These lowfrequency fields are generated by the reader and serve to activate the transponder and to communicate with the transponder. Messages from the transponder to the reader are transmitted via 433 MHz. Once a transponder is brought into the sphere of the low frequecy field, it is activated and gets recorded by the reader. Reader and transponder will remain in a constant communication with each other until the transponder leaves the field. The transponder can also send out an acoustic signal when it is detected by the reader. An 125 kHz interface is used for data exchange with PRX 5 reader or ADA. After activation, the transponder sends data to the reader for about 3 seconds. To activate the transponder again, it must first be removed from the reader field and then brought in again. m_en_tpu-4030-pcb_pro_v111115_de_bf 4. Activating the Transponder For transportation, the transponders are set to transport mode. Before use. they must be activated. The activation is done by an Amantag compact reader. The DIP switch B6 needs to be set to ON position. Attention! Possibly, the field strength must be increased. Therefore, set DIP switch B1 to B4 to “ON” position. After configuration, the transponder should be placed close to the reader (it requires high power to wake up the transponder from transport mode). As long as the switch B6 is in ON position, there is no reaction from the reader to the transponder. Whether a transponder is active can only be revealed when the switch B6 is in OFF position. This way, several transponders are activated simultaneously. After activation, the switches must all be brought back into starting position. Attention! Once activated, transponders can not be switched into transport mode again. 5. Acoustic Signal The TPU 4030 has a built-in beeper, which can be activated by an Amantag compact reader. The acoustic signal is triggered by an Amantag compact reader whenever its door number is greater than seven. The picture below shows the switches A5 - A8 set to door number 9. Attention! Once activated, the alarm can only be disabled by an ADA unit (article number: 0723.000). Otherwise, the transponder will beep, until the battery is empty. 6. Battery Monitoring The battery status of the PrisonTag can be monitored. An ADA unit (article number: 0723.000) can read and display the current battery status. For more information, please refer to the description of the ADA unit. m_en_tpu-4030-pcb_pro_v111115_de_bf Headquarters Germany: deister electronic GmbH Hermann-Bahlsen Str. 11 30890 Barsinghausen Tel.: +49 (0) 51 05 - 51 61 11 Fax: +49 (0) 51 05 - 51 62 17 info.de@deister.com www.deister.com France: deister electronic france 101 rue Pierre Semard 92320 Chatillon Tel.: +33 (0) 1 47 - 35 78 78 Fax: +33 (0) 1 47 - 35 92 59 info.fr@deister.com Great Britain: deister electronic (UK) Ltd. Stapleton Way, Enterprise Park Spalding, Lincolnshire PE11 3YQ Tel.: +44 (0) 1775 - 717100 Fax: +44 (0) 1775 - 717101 info.uk@deister.com Art. #TBA Japan: deister electronic Japan, LTD. Toshiba Hoshikawa Bldg. 4F 2-4 Kawabe-chô Hodogaya-ku, Yokohama-shi Kanagawa, 240-0001 Tel.: +81 (0) 45 340 1831 Fax: +81 (0) 45 340 1801 info.jp@deister.com Americas and Caribbean: Deister Electronics USA, Inc. 9303 Grant Avenue Manassas, VA 20110 Tel.: +1 703 - 368 2739 Fax: +1 703 - 368 9791 info.us@deister.com m_en_tpu-4030-pcb_pro_v111115_de_bf
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Print high-res Author : Björn Create Date : 2011:11:23 11:31:25+01:00 Modify Date : 2011:11:23 11:31:25+01:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Title : m_en_tpu-4030-pcb_pro_v111115_de_bf Creator : Björn Producer : Acrobat Distiller 9.4.6 (Windows) Document ID : uuid:1f9bcd71-0982-4c3a-a523-79c40c03a11e Instance ID : uuid:ad295239-a2f0-4c06-beb2-1e2e955b847b Page Count : 8EXIF Metadata provided by EXIF.tools