Device Solutions PA0002 Sensor Board Module User Manual Installation Instructionsx

Device Solutions Inc. Sensor Board Module Installation Instructionsx

Users Manual

Download: Device Solutions PA0002 Sensor Board Module User Manual Installation Instructionsx
Mirror Download [FCC.gov]Device Solutions PA0002 Sensor Board Module User Manual Installation Instructionsx
Document ID1773175
Application IDlZ18az8ehkv3LUd1+vhvoA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize14.66kB (183191 bits)
Date Submitted2012-08-23 00:00:00
Date Available2013-02-19 00:00:00
Creation Date2017-10-30 12:02:48
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-10-30 12:02:48
Document TitleMicrosoft Word - Installation Instructions.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: WCL

Device Solutions
Collector & Sensor
Installation Instructions
Revision History: PRELIMINARY
FCC Caution:
Changes or modifications not expressly approved by Device Solutions could void the user’s authority to operate
this equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:




Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Collector Installation
1. Provision the Collector in the server
2. Remove the four 3/8” #4 screws into the corners of
the enclosure top that fasten it to the enclosure
base.
3. Connect the battery
4. Reinstall the four 3/8” #4 screws into the corners of
the enclosure top that fasten it to the enclosure
base.
5. Attach the enclosure to a surface. The best RF
performance is obtained by mounting the Collector
to a vertical service.
6. Connect external power to the collector
Sensor Installation
1. Remove the screws that hold the top of the Sensor's
enclosure to the base
2. Verify the signal strength at the Sensor
a. Open the Collector press the button to enter
"install mode".
b. Wait for the internal green LED to illuminate.
c. Reboot the Sensor by removing and re‐installing
the 9 volt battery
d. Place the Sensor within 50 feet line of sight of the
Collector
e. Wait for the Sensor's internal LED to illuminate
(up to 1 minute)
f. The color of the LED indicates the following (red –
poor signal quality, yellow – moderate signal
quality, green good signal quality)
g. Move the Collector and/or Sensor until the Sensor
displays a good signal condition for at least 5
consecutive seconds
h. Repeat c through g for each sensor
i. Disable "install mode" for the Collector by
pressing the button on the collector again (if this
step is forgotten the collector will exit install
mode in one hour)
j. Turn off each Sensor by removing the 9 volt
battery
3. Loosen the nut from the cable restraint shown
above
4. Pass the transducer wires through the cable
restraint
5. Tighten the cable restraint nut to the cable restraint
6. Attach the transducer wires to the terminal blocks.
This connection depends on the type of transducer
used. See the appendix for an example.
7. The total length of the transducer cable must be
less than 10 feet
8. Install the 9 volt battery in the sensor
9. Re‐install the screws that hold the top of the
enclosure to the base
10. Attach the enclosure to a surface. The best RF
performance is obtained by mounting the Sensor
vertically.
 Appendix:
Ashcroft Pressure Transducer Installation
Bare wire (shield drain wire) from the transducer is
unused.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Extract, Print high-res
Author                          : WCL
Create Date                     : 2012:08:22 10:44:23-04:00
Modify Date                     : 2012:08:23 15:14:13-04:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Title                           : Microsoft Word - Installation Instructions.docx
Creator                         : WCL
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2012:08:23 15:14:13-04:00
Producer                        : Acrobat Distiller 10.1.3 (Windows)
Document ID                     : uuid:2f76f237-dd00-4e5c-9945-a2700f810492
Instance ID                     : uuid:409df90e-2bad-4bdf-a2c2-e0ba70803605
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OXW-PA0002

Navigation menu