Dialoc ID MR50-0001 MR50 Industrial Reader RFID User Manual manual
Dialoc ID B.V. MR50 Industrial Reader RFID manual
manual
Product Manual Version 1.2 MR50 Industrial Reader — Product Manual v1.2 © 2009 Dialoc ID. All rights reserved. Dialoc ID makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Dialoc ID shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Dialoc ID assumes no responsibility for the use or reliability of its equipment on equipment that is not furnished by Dialoc ID. Dialoc ID reserves the right to modify the software and hardware described in this manual at any time without prior notice. Trademarks: This manual covers the following items: • MR50 Industrial Reader with external antenna Last version date: March 2009 Manual versions: Version 1.0: first version Version 1.1: external antenna added Version 1.2: FCC approval Page 2 of 12 MR50 Industrial Reader — Product Manual v1.2 Table Of Contents Introduction--------------------------------------------------------------------------------- 4 Regulatory information ----------------------------------------------------------------- 5 2.1 2.2 2.3 3.1 3.2 3.3 3.4 3.5 FCC Information to User------------------------------------------------------------------------------------5 FCC Electronic Emission Notices ------------------------------------------------------------------------5 FCC Radio Frequency Interference statement--------------------------------------------------------5 Installation guide ------------------------------------------------------------------------- 6 Mounting--------------------------------------------------------------------------------------------------------6 External antenna mounting --------------------------------------------------------------------------------6 Power supply --------------------------------------------------------------------------------------------------6 Connections ---------------------------------------------------------------------------------------------------7 Led control -----------------------------------------------------------------------------------------------------7 Appendix A Reader specifications --------------------------------------------------- 8 Appendix B External antenna specifications ------------------------------------10 Appendix C Declaration of Conformity --------------------------------------------11 Page 3 of 12 MR50 Industrial Reader — Product Manual v1.2 1 Introduction The MR50 Industrial Reader is a general purpose 13.56 MHz RFID reader. The MR50 Industrial Reader is fully sealed in epoxy to protect the electronics from a harsh environment. There are no user serviceable parts inside the reader. The MR50 Industrial Reader communicates via the RS232/EIA-232 interface. The use of this standard communication interface makes it easy to connect the MR50 Industrial Reader to a host system. The MR50 Industrial Reader also contains a bi-color LED which can be hardware-controlled by means of two inputs. Controlling the MR50 Industrial Reader is done by the T=0 protocol which is not a part of this manual. For more information about the T=0 protocol we refer to the Inside Contactless manual M220H. Remark: the T=0 protocol is a worldwide standardized protocol. Although, it is possible that Inside Contactless also integrated custom made commands into this T=0 protocol. When T=0 protocol is written in this manual, the Inside Contactless T=0 protocol is meant. See also: http://www.insidecontactless.com Attention This manual describes the MR50 Industrial Reader with external reader. The MR51 Industrial Reader has the same functionality and specification but comes with an internal antenna. Ask your dealer for more information. Page 4 of 12 MR50 Industrial Reader — Product Manual v1.2 2 Regulatory information 2.1 FCC Information to User This product does not contain any user serviceable components and is to be used with approved antennas only. Any product changes or modifications will invalidate all applicable regulatory certifications and approvals 2.2 FCC Electronic Emission Notices This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference 2. This device must accept any interference received, including interference that may cause undesired operation. 2.3 FCC Radio Frequency Interference statement This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference, in which case the user will be required to correct the interference at his own expense. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help Page 5 of 12 MR50 Industrial Reader — Product Manual v1.2 3 Installation guide 3.1 Mounting The MR50 Industrial Reader can be mounted on a flat surface with two 4 mm screws. Metal constructions close to the reader-antenna can absorb energy from the reader excite field and can detune the antenna. The read range of the internal antenna will therefore be reduced if the reader-antenna is located on metal surfaces or in close vicinity of metal objects. The amount of reduction will be a factor of the amount of metal and the distance the readerantenna is from the metal. Please check carefully if metal constructions in your operational environment allow for enough margin to guarantee proper operation of the reader. 3.2 External antenna mounting The external antenna can be mounted on a flat surface with five 3 mm screws and five 3 mm nylon spacers (not supplied). Do not over tighten the screws! As mentioned in chapter 3.1, the read range of the internal antenna will therefore be reduced if the reader-antenna is located on metal surfaces or in close vicinity of metal objects. Note The trimmer (C5) on the external antenna is factory adjusted; please do not touch this trimmer. If the operational situation requires large metal constructions close to the antenna, part of the detuning can be compensated for by readjusting C5. In that case please contact Dialoc ID for more instructions. 3.3 Power supply The recommended power supply for the MR50 Industrial Reader is 13,8Vdc up to 24Vdc. The maximum power consumption at 13,8Vdc is 120mA. Page 6 of 12 MR50 Industrial Reader — Product Manual v1.2 3.4 Connections The MR50 Industrial Reader has one connector for power connection, serial communication and led-control. The layout of the connector is as follows: Pin number Function Ground (GND) TX (transmit data) RX (receive data) Led A Not connected Not connected Led B Power (+13,8 – 24Vdc) 3.5 Led control The MR50 Industrial Reader has a bi-color LED which can be controlled from the inputs of the reader. The following table shows how the colors are generated: Led A Led B Color Remarks Low High Green High level equals +13,8 – 24Vdc High Low Red Low level equals GND High High Orange Page 7 of 12 MR50 Industrial Reader — Product Manual Appendix A A.1 Reader specifications Power Input voltage 13,8 - 24Vdc +/-5% Current consumption max. 120 mA @ 13,8V dc Power down option Coupler power down (via software) Overvoltage protection No Polarity protection Yes A.2 Connection Connector type 8 way Wieland PCB connector Contra part Supplied Antenna connection 400 mm lead with a MCX connector A.3 v1.2 Hardware Read distance Up to 15 cm (depending on the type of tag) Labels See the Inside Contactless manual M220H for more details Operating temperature -20 / +50° C A.4 In/outputs Led A and B input voltage A.5 13,8 - 24V dc (current consumption max. 25 mA @ 24V dc) Communication interface / protocol ISO standards 14443 A/B, 15693, FeliCa™ Interface RS232 / EIA-232 Baud rate Default 9600 bps (up to 115.2 kbps) Coupler M220-G2 of Inside Contactless Protocol T=0 of Inside Contactless A.6 Housing Type, color PVC casing, light gray Waterproof Front side IP67, back side open connector Dimensions see below Page 8 of 12 MR50 Industrial Reader — Product Manual Side view Back view 4mm 8mm Front view v1.2 90mm 400 mm lead to antenna (MR50 Industrial Reader only) MCX connector 4mm 8mm 48mm 127mm 110mm Bi-color LED 25mm 2mm 50mm 38mm 4 mm mounting holes (2x) Page 9 of 12 MR50 Industrial Reader — Product Manual Appendix B B.1 v1.2 External antenna specifications Power Impedance 50 ohm @ 13.56 MHz Over voltage protection No Polarity protection No B.2 Connection Connector type B.3 MCX connector Hardware Read distance Up to 15 cm (depending on the type of tag) Operating temperature -20 / +50° C B.4 Antenna housing Type Printed circuit board Waterproof No Dimensions see below Front view Side view Holes (2x) for wire retention C5 trimmer 3 mm mounting hole (5x) additional 3 mm nylon spacer (5x) 10mm 69mm 50mm 100mm 90mm MCX chassis connector 2mm 10mm 46mm 10mm 50mm 90mm 100mm Page 10 of 12 MR50 Industrial Reader — Product Manual Appendix C v1.2 Declaration of Conformity Page 11 of 12 MR50 Industrial Reader — Product Manual v1.2 NOTES DIALOC ID DALTONSTRAAT 42-44 3846 BX HARDERWIJK TEL +31 (0) 341 42 09 40 FAX +31 (0) 341 42 50 33 www.dialocid.com support-rfid@dialocid.com Page 12 of 12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 8.0.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2009:03:09 10:17:40+01:00 Create Date : 2009:03:09 10:17:40+01:00 Format : application/pdf Title : Microsoft Word - MR5x Industrial Reader - Product Manual _v1.2_.doc Creator : Rico Document ID : uuid:61ac170b-bd32-43b2-ba81-afed28bb272a Instance ID : uuid:a70388be-d9ce-45d1-be8a-44968ea48aa4 Page Count : 12 Author : RicoEXIF Metadata provided by EXIF.tools