Digi XBPS3B XBEE PRO XSC User Manual manual xs oem rf module v42b5

Digi International Inc XBEE PRO XSC manual xs oem rf module v42b5

Manual

Download: Digi XBPS3B XBEE PRO XSC User Manual manual xs oem rf module v42b5
Mirror Download [FCC.gov]Digi XBPS3B XBEE PRO XSC User Manual manual xs oem rf module v42b5
Document ID1583786
Application IDJT7fSCyVv/+gOEtQ4bts4Q==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize67.06kB (838211 bits)
Date Submitted2011-11-18 00:00:00
Date Available2011-11-18 00:00:00
Creation Date2011-11-03 11:22:03
Producing SoftwareAcrobat Distiller 10.0.0 (Windows)
Document Lastmod2011-11-03 11:22:22
Document Titlemanual_xs_oem_rf-module_v42b5.book
Document CreatorPScript5.dll Version 5.2.2
Document Author: sfatunbi

XBee-PRO® XSC RF Module
XBee-PRO® XSC RF Module
RF Module Operation
RF Module Configuration
Appendices
Product Manual
For RF Module Part Number:
XBP09-XC…
900 MHz OEM RF Modules by Digi International Inc.
11001 Bren Road East
Minnetonka, MN 55343
www.digi.com
90000938_C
11, 3, 2011
XBee‐PRO®XSC RF Module ‐ Product Manual
© 2011 Digi International, Inc. All rights reserved
No part of the contents of this manual may be transmitted or reproduced in any
form or by any means without the written permission of Digi International, Inc.
XBee‐PRO® is a registered trademark of Digi International Inc.
Technical Support:
Phone: (801) 765‐9885
Live Chat: www.digi.com
© 2011 Digi International, Inc.
ii
XBee‐PRO® XSC OEM RF Modules
Contents
1. XBee-PRO® XSC OEM RF Module 4
Key Features 4
Worldwide Acceptance 4
Specifications 5
Pin Signals 6
Electrical Characteristics 7
Timing Specifications 7
Mechanical Drawings 8
2. RF Module Operation 9
Serial Communications 9
UART-Interfaced Data Flow 9
Serial Data 9
Flow Control 10
Modes of Operation 11
Idle Mode 11
Transmit Mode 11
Sleep Mode 13
Command Mode 15
3. RF Module Configuration 18
XBee Programming Examples 18
AT Commands 18
Binary Commands 18
Command Reference Table 19
Command Descriptions 20
Agency Certifications 37
FCC (United States) Certification 37
Labeling Requirements 37
FCC Notices 37
Limited Modular Approval 38
FCC-approved Antennas 38
IC (Industry Canada) Certification 38
Additional Information 42
1-Year Warranty 42
Contact Digi 42
© 2011 Digi Internaitonal, Inc.
XBee‐PRO® XSC OEM RF Modules
1. XBee‐PRO® XSC OEM RF Module
The XBee-PRO XSC (900 MHz) OEM RF Modules were
engineered to afford OEMs and integrators an easy-to-use RF
solution that provides reliable delivery of critical data between
remote devices. These modules come configured to sustain
reliable long-range wireless links.
The XBee Module is a drop-in wireless solution that transfers a
standard asynchronous serial data stream.
1.1. Key Features
Long Range Data Integrity
Easy-to-Use
XBee-PRO XSC- S3:
• Indoor/Urban: 1200' (370m)
• Continuous RF data stream
up to 9600 bps
• Outdoor line-of-sight: Up to 6 miles (9.6
km)
• No configuration required for out-of-the-box
RF data communications
• Outdoor line-of-sight: Up to 15 miles (24
km) w/ high gain antenna
• Advanced configurations available through
standard AT & binary Commands
• Receiver Sensitivity: -106 dBm,
• Portable (small form factor easily designed
into a wide range of data radio systems)
XBee-PRO XSC-S3B:
• Indoor/Urban range: 2000’ (610 m)
• Outdoor line-of-sight range: 9 miles (14 km)
• Receiver Sensitivity: -109 dBm
Advanced Networking & Security
• Software-selectable serial interface baud rates
• I/O Support: CTS, RTS (& more)
• Support for multiple data formats
(parity, start and stop bits, etc.)
• Power-saving Sleep Modes
• True peer-to-peer (no “master” required)
communications
• Point-to-point & point-to-multipoint topologies supported
• Retries and Acknowledgements
• 7 hopping channels, each with over 65,000
available network addresses
• FHSS (Frequency Hopping Spread Spectrum)
1.1.1. Worldwide Acceptance
FCC Certified (USA) - Refer to Appendix A for FCC Requirements.
Systems that include XBee-PRO Modules inherit Digi’s FCC Certification
ISM (Industrial, Scientific & Medical) frequency band
Manufactured under ISO 9001:2000 registered standards
XBee-PRO™ XSC (900 MHz) OEM RF Modules are approved for use in US and
Canada.
RoHS compliant
© 2011 Digi International, Inc.
XBee‐PRO® XSC OEM RF Modules
1.2. Specifications
Table 1‐01.
XBee‐PRO XSC OEM RF Module Specifications
Specification
XBee-PRO XSC (S3) (900 MHz)
OEM RF Module
XBee-PRO XSC
(S3B)
Up to 1200ft (370m)
up to 2000ft (610m)
Up to 6 miles (9.6km) w/ dipole antenna
Up to 15 miles (24 km) w/ high-gain antenna
Up to 9 miles (14km) w/
dipole antenna
Up to 28 miles (45km) w/
high-gain antenna
Performance
Indoor/Urban Range
Outdoor line-of-sight Range
125 - 65,000 bps
(Software selectable, includes non-standard baud rates)
Interface Data Rate
Throughput Data Rate
9,600 bps
9.6 kbps or 19.2kbs
10 kbps
10 kbps or 20kbs
100 mW (+20 dBm)
24dBm @ 215mA
-106dBm
-109dBm at 9600 baud
-107dBm at 19200 baud
3.0-3.6 VDC regulated
2.4 to 3.6v
RF Data Rate
Transmit Power Output
Receiver Sensitivity
Power Requirements
Supply Voltage
Receive Current
65mA
26mA typical
Transmit Current
265mA
215mA at 24dBm
50 uA
2.5uA typical @3.3v
Power Down Current
General
Frequency Range
902-928 MHz (located in the 900MHz ISM Band)
Spread Spectrum
Frequency Hopping
Network Topology
Point-to-Point, Peer-to-Peer, Point-to-Multipoint
Channel Capacity
7 hop sequences share 25 frequencies
Board-level Serial Data Interface (S3B)
3V CMOS UART (5V-tolerant)
3V CMOS UART
Physical Properties
Module Board Size
Weight
Connector
1.297" x 0.962" x 0.215 (3.29 cm x 2.44 cm x 0.546 cm)
Note: Dimensions do not include connector/antenna or pin lengths
5 to 8 grams, depending on the antenna option
2 rows of 10 pins, 22mm apart with 2mm spaced male Berg-type headers
Operating Temperature
-40 to 85º C (industrial)
Antenna Options
Integrated Wire
Integrated Helical
¼ wave monopole, 3.25” (8.26 cm) length, 1.9 dBi Gain
0.315" (0.8 cm) height
RF Connector
Reverse-polarity SMA or U.FL
Impedance
50 ohms unbalanced
Certifications)
FCC Part 15.247
MCQ-XBEEXSC
Industry Canada (IC)
1846A-XBEEXSC
MCQ-XBPS3B
1846A-XBPS3B
Europe
N/A
RoHS
Compliant
Australia
N/A
© 2011 Digi International, Inc.
Pending
XBee‐PRO® XSC OEM RF Modules
1.3. Pin Signals
Figure 1‐01. XBee‐PRO XSC OEM RF Module Pin Numbers (top view, shield underneath)
Table 1‐02.
J1 Pin Signal Descriptions
(Low‐asserted signals distinguished with a horizontal line over signal name.)
Module Pin
Public Signal
VCC
Notes
When
Active
Function
Supply Voltage
I/O
DO (Data Out)
n/a
Serial data exiting the module (to the UART host). Refer to the
Serial Communications section for more information
DI (Data In
n/a
Serial data entering the module (from UART host). Refer to the
Serial Communications section for more information.
DO3 / RX LED
high
Pin is driven high during RF data reception; otherwise, the pin is
driven low. Refer to the CD Command section to enable.
Reset
**Has a pull up
I/O
resistor
low
Re-boot module.(minimum pulse is 90us) Open Drain
configuration. Module will drive reset line low momentarily on
reboot and power up.
Config
*Has a pull up
resistor
low / high
Pin can be used as a backup method for entering Command
Mode during power-up. Primary method is with “+++”. Refer to
the AT Commands section for more information.
Driven high
NC
DI3 / SLEEP
10
GND
*Has a pull up
resistor
Do not Connect
Do not Connect
high
By default, DI3 pin is not used. To configure this pin to support
Sleep Modes, refer to the Sleep Mode, SM Command and PW
Command sections.
Ground
11
Driven high
Do not Connect
12
DO2 / CTS / RS-485
Enable
low
CTS(clear-to-send) flow control - When pin is driven low, UART
host is permitted to send serial data to the module. Refer to the
Serial Communications and CS Command sections for more
information.
---------------------------------------------------------------RS-485 Enable - To configure this pin to enable RS-485 (2-wire
or 4-wire) communications, refer to the Serial Communications
and CS Command sections.
13
ON / Sleep
high
high = Indicates power is on and module is not in Sleep Mode.
Low = Sleep mode or module is unpowered
14
VREF
n/a
Not used on this module. For compatibility with other XBee
modules, we recommend connecting this pin to a voltage
reference if Analog sampling is desired. Otherwise, connect to
GND.
n/a
low = TX - Pin pulses low during transmission
-------------------------------------------------------------high = PWR - Indicates power is on and module is not in Sleep
Mode
low
RTS (request-to-send) flow control - By default, this pin is not
used. To configure this pin to regulate the flow of serial data
exiting the module, refer to the Serial Communications and RT
Command sections.
-------------------------------------------------------------CMD -Refer to Binary Commands and RT Command sections
to enable binary command programming.
17
Driven low
Do not Connect
18
Driven low
Do not Connect
19
Driven low
Do not Connect
20
Driven low
Do not Connect
15
16
TX / PWR
DI2 / RTS / CMD
*Has a pull
down resistor
Note:*S3 has a 100k pull‐up. S3B has internal pull‐up. **S3 has 10k pull‐up. S3B has internal pull‐up.
© 2011 Digi International, Inc.
XBee‐PRO® XSC OEM RF Modules
1.4. Electrical Characteristics
Figure 1‐02. System Block Diagram Basic wireless link between hosts
The data flow sequence is initiated when the first byte of data is received in the DI Buffer of the
transmitting module (XBee Module A). As long as XBee Module A is not already receiving RF data,
data in the DI Buffer is packetized, then transmitted over-the-air to XBee Module B.
1.4.1. Timing Specifications
Figure 1‐03. Timing Specifications (“A” and “B” refer to Figure 1‐02.)
Host A sends serial data to XBee Module A
D IN A
T ST
RFOUT A
After TST , contents of D IN Buffer
are assembled into packet and transmitted
A Transmits over air
B Receives
T TX
TX/PWR LED on XBee Module A pulses off
briefly to indicate RF transmission
TX LED A
T TL
If 16-bit CRC checks out, data is shifted out
serial port to Host B
D OUT B
TCLDL
(Optional) Set ATCS = 1 to use CTS as RS-485
TX enable low-asserted signal
CTS B
TCHDH
RX LED B
RX LED pulses on briefly to indicate RF reception
T RL
© 2011 Digi International, Inc.
XBee‐PRO® XSC OEM RF Modules
Table 1‐03.
AC Characteristics (SY parameter = 0, symbols correspond to Figure 1‐02 and Figure 1‐03.)
Symbol
Description
TTX
Latency from the time data
is transmitted until received
TTL
Time that TX/PWR pin is
driven low
9600 baud rate
(32 byte packet)
72.0 ms
For 0 < B < 40,
T = 46.27 + (0.73 * B) ms
16.8 ms
TRL
Time that RX LED pin is
driven high
25.6 ms
TST
Channel Initialization Time
35.0 ms
Table 1‐04.
9600 timing
(B=number of bytes)
For B >= 39 bytes,
T = 74.80 ms
For 0 < B < 14,
T = 6.50 + (0.8 * B) ms
For B > 13
T = 16.80 ms
For 0 < B < 37,
T = 1.63 + (0.794 * B)
For B > 36,
T = 30.2 ms
35.0 ms
DC Characteristics (Vcc = 3.0‐3.6 VDC)
Symbol
Parameter
Condition
Vcc
Module Supply Voltage
VIL
Input Low Voltage
All input signals
VIH
Input High voltage
All input signals
VOL
Output Low-Level
Voltage
Iout = Iout_Max
VOH
Output High-Level
Voltage
Iout = Iout_Max
IL
Input Leakage Current
***With Pull-up resistors
disabled
IO1
Output Current
IO2
Output Current
Min
Typical
Max
Units
*3.0
3.6
-0.3
0.3Vcc
0.7Vcc
Vcc + 0.3 **
0.4
Vcc-0.4
40
400
nA
pins 2, 15 (Dout, ~TX/
Pwr)
mA
pins 4, 12, 13
(DCD,~CTS,ON/~Sleep)
mA
Note: *Min Voltage for S3B is 2.4v, however Max Power will be reduced and Sensitivity may degrade.
**S3 is tolerant up to 5.5v on input pins.
***S3B can have pull‐ups enabled and still maintain low leakage current.
1.5. Mechanical Drawings
Figure 1‐04. Mechanical Drawings
© 2011 Digi International, Inc.
XBee‐PRO® XSC OEM RF Modules
2. RF Module Operation
2.1. Serial Communications
The XBee module interfaces to a host device through a CMOS-level asynchronous serial port.
Through its serial port, the module can communicate with any UART voltage compatible device or
through a level translator to any RS-232/485/422 device.
2.1.1. UART-Interfaced Data Flow
Devices that have a UART interface can connect directly through the pins of the XBee module as shown in the
figure below.
Figure 2‐01. System Data Flow Diagram in a UART‐interfaced environment
(Low‐asserted signals distinguished with horizontal line over signal name.)
DIN (data in)
DIN (data in)
DOUT (data out)
DOUT (data out)
2.1.2. Serial Data
Data enters the XBee module through the DI pin as an asynchronous serial signal. The signal
should idle high when no data is being transmitted.
The UART performs tasks, such as timing and parity checking, that are needed for data
communications. Serial communication consists of two UARTs, one being the XBee's and the other
being the Microcontroller's, configured with compatible parameters (baud rate, parity, start bits,
stop bits, data bits) to have successful communication. Each data packet consists of a start bit
(low), 8 data bits (least significant bit first) and a stop bit (high). The following figure illustrates
the serial bit pattern of data passing through the module.
Figure 2‐02. UART data packet 0x1F (decimal number ʺ31ʺ) as transmitted through the XBee Module
Example Data Format is 8‐N‐1 (bits ‐ parity ‐ # of stop bits)
© 2011 Digi International, Inc.
XBee‐PRO® XSC OEM RF Modules
2.1.3. Flow Control
Figure 2‐03. Internal Data Flow Diagram (The five most commonly‐used pin signals shown.)
DI (Data In) Buffer and Flow Control
When serial data enters the XBee module through the DI Pin, then the data is stored in the DI
Buffer until it can be transmitted.
When the RO parameter threshold is satisfied (refer to Transmit Mode and Command Descriptions
sections for more information), the module attempts to initialize an RF connection. If the module is
already receiving RF data, the serial data is stored in the module's DI Buffer. If the DI buffer
becomes full, hardware or software flow control must be implemented in order to prevent overflow
(loss of data between the host and XBee OEM RF Module).
How to eliminate the need for flow control:
• Send messages that are smaller than the DI buffer size, which is generally around 1,000
bytes.
• Interface at a lower baud rate (BD parameter) than the fixed RF data rate with the Retries
functionality (RR parameter) disabled.
Two cases in which the DI Buffer may become full and possibly overflow:
• If the serial interface data rate is set higher than the RF data rate of the module, the module
will receive data from the host faster than it can transmit the data over-the-air.
• If the module is receiving a continuous stream of data, monitoring data on a network, or
awaiting acknowledgments for Retries functionality, any serial data that arrives on the DI pin
is placed in the DI Buffer. The data in the DI buffer will be transmitted over-the-air when the
module no longer detects RF data in the network.
Hardware Flow Control (CTS). When the DI buffer is 65 bytes away from being full; by default,
the module de-asserts (high) CTS to signal to the host device to stop sending data [refer to FT
(Flow Control Threshold) and CS (DO2 Configuration) Commands]. CTS is re-asserted after the DI
Buffer has 34 bytes of memory available.
Software Flow Control (XON). XON/XOFF software flow control can be enabled using the FL
(Software Flow Control) command.
DO (Data Out) Buffer and Flow Control
When RF data is received, the data enters the DO buffer and is then sent out the serial port to a
host device. Once the DO Buffer reaches capacity, any additional incoming RF data is lost.
Two cases in which the DO Buffer may become full and possibly overflow:
• If the RF data rate is higher than the set interface data rate of the module, the module will
receive data from the transmitting module faster than it can send the data to the host.
• If the host does not allow the RF module to send data out of the DO buffer because of hardware or software flow control.
Hardware Flow Control (RTS). If RTS is enabled for flow control (RT Parameter = 2), data will
not be sent out the DO Buffer as long as RTS (pin 16) is de-asserted.
Software Flow Control (XOFF). XON/XOFF software flow control can be enabled using the FL
(Software Flow Control) Command. This option only works with ASCII data.
© 2011 Digi International, Inc.
10
XBee‐PRO® XSC OEM RF Modules
2.2. Modes of Operation
XBee-PRO® XSC RF Modules operate in five modes.
Figure 2‐04. Modes of Operation
2.2.1. Idle Mode
When not receiving or transmitting data, the RF module is in Idle Mode. The module shifts into the
other modes of operation under the following conditions:
• Transmit Mode (Serial data is received in the DI Buffer)
• Receive Mode (Valid RF data is received through the antenna)
• Sleep Mode (Sleep Mode condition is met)
• Command Mode (Command Mode Sequence is issued)
2.2.2. Transmit Mode
When the first byte of serial data is received from the UART in the DI buffer, the modem attempts
to shift to Transmit Mode and initiate an RF connection with other modems. After transmission is
complete, the modem returns to Idle Mode.
RF transmission begins after either of the following criteria is met:
1. RB bytes have been received in the DI buffer and are pending for RF transmission [refer to RB
(Packetization Threshold) command, p34].
- The RB parameter may be set to any value between 1 and the RF packet size (PK), inclusive.
When RB = 0, the packetization threshold is ignored.
2. At least one character has been received in the DI buffer (pending for RF transmission) and RO
time has been observed on the UART [refer to RO (Packetization Timeout) command].
- The timeout can be disabled by setting RO to zero. In this case, transmission will begin after RB
bytes have been received in the DI buffer.
Note: RF reception must complete before the modem is able to enter into Transmit Mode.
After either RB or RO conditions are met, the modem then initializes a communications channel.
[Channel initialization is the process of sending an RF initializer that synchronizes receiving
modems with the transmitting modem. During channel initialization, incoming serial data
accumulates in the DI buffer.]
Serial data in the DI buffer is grouped into RF packets [refer to PK (RF Packet Size)]; converted to
RF data; then transmitted over-the-air until the DI buffer is empty.
RF data, which includes the payload data, follows the RF initializer. The payload includes up to the
maximum packet size (PK Command) bytes. As the transmitting modem nears the end of the
transmission, it inspects the DI buffer to see if more data exists to be transmitted. This could be
the case if more than PK bytes were originally pending in the DI buffer or if more bytes arrived
from the UART after the transmission began. If more data is pending, the transmitting modem
assembles a subsequent packet for transmission.
© 2011 Digi International, Inc.
11
XBee‐PRO® XSC OEM RF Modules
RF Packet
The RF packet is the sequence of data used for communicating information between MaxStream
Modems. An RF Packet consists of an RF Initializer and RF Data.
When streaming multiple RF packets, the RF Initializer is only sent in front of the first packet.
RF Initializer
An RF initializer is sent each time a new connection sequence begins. The RF initializer contains
channel information that notifies receiving modems of information such as the hopping pattern
used by the transmitting modem. The first transmission always sends an RF initializer.
An RF initializer can be of various lengths depending on the amount of time determined to be
required to prepare a receiving modem. For example, a wake-up initializer is a type of RF initializer used to wake remote modems from Sleep Mode (Refer to the FH, LH, HT and SM Commands for more information). The length of the wake-up initializer should be longer than the
length of time remote modems are in cyclic sleep.
© 2011 Digi International, Inc.
12
XBee‐PRO® XSC OEM RF Modules
Header
The header contains network addressing information that filters incoming RF data. The receiving modem checks for a matching Hopping Channel (HP parameter), Vendor Identification Number (ID parameter) and Destination Address (DT parameter). Data that does not pass through
all three network filter layers is discarded.
CRC (Cyclic Redundancy Check)
To verify data integrity and provide built-in error checking, a 16-bit CRC (Cyclic Redundancy
Check) is computed for the transmitted data and attached to the end of each RF packet. On the
receiving end, the receiving modem computes the CRC on all incoming RF data. Received data
that has an invalid CRC is discarded. Receive Mode
If a module detects RF data while operating in Idle Mode, the module transitions into Receive Mode
to start receiving RF packets.
Figure 2‐05. Reception of RF Data
After a packet is received, the module
checks the CRC (cyclic redundancy check)
to ensure that the data was transmitted
without error. If the CRC data bits on the
incoming packet are invalid, the packet is
discarded. If the CRC is valid, the packet
proceeds to the DO Buffer.
The module returns to Idle Mode after valid
RF data is no longer detected or after an
error is detected in the received RF data. If
serial data is stored in the DI buffer while
the module is in Receive Mode, the serial
data will be transmitted after the module is
finished receiving data and returns to Idle
Mode.
2.2.3. Sleep Mode
Sleep Modes enable the XBee module to operate at minimal power consumption when not in use.
The following Sleep Mode options are available:
• Pin Sleep
• Cyclic Sleep
For the module to transition into Sleep Mode, the module must have a non-zero SM (Sleep Mode)
Parameter and one of the following must occur:
• The module is idle (no data transmission or reception) for a user-defined period of time [Refer
to the ST (Time before Sleep) Command].
• SLEEP is asserted (only for Pin Sleep option).
In Sleep Mode, the module will not transmit or receive data until the module first transitions to
Idle Mode. All Sleep Modes are enabled and disabled using SM Command. Transitions into and out
of Sleep Modes are triggered by various events as shown in the table below.
© 2011 Digi International, Inc.
13
XBee‐PRO® XSC OEM RF Modules
Table 2‐01.
Sleep Mode
Setting
Pin Sleep
(SM = 1)
Cyclic Sleep
(SM = 3-8)
Summary of Sleep Mode Configurations
Transition into
Sleep Mode
Microcontroller can shut down and wake
modules by asserting (high) SLEEP (pin 9).
Note: The module will complete a
transmission or reception before activating
Pin Sleep.
Automatic transition to Sleep Mode occurs
in cycles as defined by the SM (Sleep
Mode) Command.
Transition out of
Sleep Mode
Related
Commands
Typical Power
Consumption
(S3)
Typical Power
Consumption
(S3B)
De-assert (low)
SLEEP (pin 9).
SM
50 µA
2.5uA
76 µA
when sleeping
2.5uA
when sleeping
After the cyclic sleep
time interval elapses.
Note: Module can be SM, ST, HT,
Note: The cyclic sleep time interval must be forced into Idle Mode LH, PW
shorter than the “Wake-up Initializer Timer” if PW (Pin Wake-up)
Command is enabled.
(set by LH Command).
Pin Sleep (SM = 1)
In order to achieve this state, SLEEP pin must be asserted (high). The module remains in Pin Sleep
until the SLEEP pin is de-asserted.
After enabling Pin Sleep, the SLEEP pin controls whether the XBee module is active or in Sleep
Mode. When SLEEP is de-asserted (low), the module is fully operational. When SLEEP is asserted
(high), the module transitions to Sleep Mode and remains in its lowest power-consuming state
until the SLEEP pin is de-asserted. SLEEP is only active if the module is setup to operate in this
mode; otherwise the pin is ignored.
Once in Pin Sleep Mode, CTS is de-asserted (high), indicating that data should not be sent to the
module. The PWR pin is also de-asserted (low) when the module is in Pin Sleep Mode.
Note: The module will complete a transmission or reception before activating Pin Sleep.
Cyclic Sleep (SM = 3-8)
Cyclic Sleep is the Sleep Mode in which the XBee module enters into a low-power state and
awakens periodically to determine if any transmissions are being sent.
When Cyclic Sleep settings are enabled, the XBee module goes into Sleep Mode after a userdefined period of inactivity (no transmission or reception on the RF channel). The user-defined
period is determined by ST (Time before Sleep) Command.
While the module is in Cyclic Sleep Mode, CTS is de-asserted (high) to indicate that data should
not be sent to the module during this time. When the module awakens to listen for data, CTS is
asserted and any data received on the DI Pin is transmitted. The PWR pin is also de-asserted (low)
when the module is in Cyclic Sleep Mode.
The module remains in Sleep Mode for a user-defined period of time ranging from 0.5 seconds to
16 seconds (SM Parameters 3 through 8). After this interval of time, the module returns to Idle
Mode and listens for a valid data packet for 100 ms. If the module does not detect valid data (on
any frequency), the module returns to Sleep Mode. If valid data is detected, the module
transitions into Receive Mode and receives incoming RF packets. The module then returns to Sleep
Mode after a Period of inactivity that is determined by ST “Time before Sleep” Command.
The module can also be configured to wake from cyclic sleep when SLEEP (pin 9) is de-asserted
(low). To configure a module to operate in this manner, PW (Pin Wake-up) Command must be
issued. Once SLEEP is de-asserted, the module is forced into Idle Mode and can begin transmitting
or receiving data. It remains active until no data is detected for the period of time specified by the
ST Command, at which point it resumes its low-power cyclic state.
Note: The cyclic interval time defined by SM (Sleep Mode) Command must be shorter than the
interval time defined by LH (Wake-up Initializer Timer).
For example: If SM=4 (Cyclic 1.0 second sleep), the LH Parameter should equal 0x0B ("1.1"
seconds). With these parameters set, there is no risk of the receiving module being asleep for the
duration of wake-up initializer transmission. “Cyclic Scanning” explains in further detail the
relationship between “Cyclic Sleep” and “Wake-up Initializer Timer”
© 2011 Digi International, Inc.
14
XBee‐PRO® XSC OEM RF Modules
Cyclic Scanning. Each RF transmission consists of an RF Initializer and payload. The wake-up
initializer contains initialization information and all receiving modules must wake during the wakeup initializer portion of data transmission in order to be synchronized with the transmitting module
and receive the data.
Figure 2‐06. Correct Configuration (LH > SM)
Length of the wake‐up initializer exceeds the time interval of Cyclic Sleep. The receiver is guaranteed to detect
the wake‐up initializer and receive the accompanying payload data.
Figure 2‐07. Incorrect Configuration (LH < SM)
Length of wake‐up initializer is shorter than the time interval of Cyclic Sleep. This configuration is vulnerable to
the receiver waking and missing the wake‐up initializer (and therefore also the accompanying payload data).
2.2.4. Command Mode
To modify or read module parameters, the module must first enter into Command Mode, the state in
which received characters on the UART are interpreted as commands. Two command types are available for programming the module:
• AT Commands
• Binary Commands
For modified parameter values to persist in the module registry, changes must be saved to non-volatile memory using WR (Write) Command. Otherwise, parameters are restored to previously saved values after the module is powered off and then on again.
AT Commands
To Enter AT Command Mode:
• Send the 3-character command sequence “+++” and observe guard times before and after
the command characters. [refer to ‘Default AT Command Mode Sequence’ below.] The ‘Terminal’ tab (or other serial communications software) of the X-CTU Software can be used to enter
the sequence.
[OR]
• Assert (low) the CONFIG pin and either turn the power going to the module off and back on.
(If using a Digi XBIB-R Interface Board, the same result can be achieved by holding the DataIn line low (also known as a break) while rebooting the module by pressing the reset button
on the module assembly [module assembly = module mounted to an interface board]).
© 2011 Digi International, Inc.
15
XBee‐PRO® XSC OEM RF Modules
Default AT Command Mode Sequence (for transition to Command Mode):
• No characters sent for one second [refer to the BT (Guard Time Before) Command]
• Input three plus characters (“+++”) within one second
[refer to the CC (Command Sequence Character) Command.]
• No characters sent for one second [refer to the AT (Guard Time After) Command.]
To Send AT Commands:
Send AT commands and parameters using the syntax shown below.
Figure 2‐8. Syntax for sending AT Commands
To read a parameter value stored in the module register, leave the parameter field blank.
The preceding example would change the module’s Destination Address to “0x1F”. To store the
new value to non-volatile (long term) memory, the Write (ATWR) command must subsequently be
sent before powering off the module.
System Response. When a command is sent to the module, the module will parse and execute
the command. Upon successful execution of a command, the module returns an “OK” message. If
execution of a command results in an error, the module returns an “ERROR” message.
To Exit AT Command Mode:
• If no valid AT Commands are received within the time specified by CT (Command Mode Timeout) Command, the module automatically returns to Idle Mode.
[OR]
• Send ATCN (Exit Command Mode) Command.
For an example of programming the RF module using AT Commands and descriptions of each configurable parameter, refer to the “RF Module Configuration” chapter.
Binary Commands
Sending and receiving parameter values using binary commands is the fastest way to change
operating parameters of the module. Binary commands are used most often to sample signal
strength (RS parameter) and/or error counts; or to change module addresses and channels for
polling systems when a quick response is necessary. Since the sending and receiving of parameter
values takes place through the same data path as 'live' data (received RF payload), follow the CTS
pin as outlined in Figure 2-012 to distinguish between the two types of data (commands vs 'live'
data).
Common questions regarding the use of binary commands:
• What are the implications of asserting CMD while live data is being sent or received?
• After sending serial data, is there a minimum time delay before CMD can be asserted?
• Is a time delay required after CMD is de-asserted before payload data can be sent?
• How to discern between live data and data received in response to a command?
CMD (pin 16) must be asserted in order to send binary commands to the module. The CMD pin can
be asserted to recognize binary commands anytime during the transmission or reception of data.
The status of the CMD signal is only checked at the end of the stop bit as the byte is shifted into
the serial port. The application does not allow control over when data is received, except by
waiting for dead time between bursts of communication.
If the command is sent in the middle of a stream of payload data to be transmitted, the command
will essentially be executed in the order it is received. If the radio is continuously receiving data,
the radio will wait for a break in the received data before executing the command. The CTS signal
will frame the response coming from the binary command request [Figure 2-09].
© 2011 Digi International, Inc.
16
XBee‐PRO® XSC OEM RF Modules
A minimum time delay of 100 µs (after the stop bit of the command byte has been sent) must be
observed before pin 5 can be de-asserted. The command executes after all parameters associated
with the command have been sent. If all parameters are not received within 0.5 seconds, the
module aborts the command and returns to Idle Mode.
Note: Binary commands that return only one parameter byte must also be written with two parameter
bytes, 0-padded, LSB first. Refer to “Programming Examples” section [pXX] for a binary programming
example.
Commands can be queried for their current value by sending the command logically ORed (bitwise) with the value 0x80 (hexadecimal) with CMD asserted. When the binary value is sent (with
no parameters), the current value of the command parameter is sent back through the DO pin.
Figure 2‐09. Binary Command Write then Read
Signal #4 is CMD (pin 16)
Signal #1 is the DIN (pin 3) signal
to the radio
Signal #2 is the DOUT (pin 2) signal
from the radio
Signal #3 is CTS (pin 12)
In this graph, a value was written to a
register and then read out to verify it.
While not in the middle of other received
data, note that the CTS signal outlines the
data response out of the module.
IMPORTANT: For the XBee module to recognize a binary command, the RT (DI2 Configuration) parameter must be set to one. If binary programming is not enabled RT = 0 or 2, the module will not recognize that the CMD pin is asserted and therefore will not recognize the data as binary commands.
© 2011 Digi International, Inc.
17
XBee‐PRO® XSC OEM RF Modules
3. RF Module Configuration
3.1. XBee Programming Examples
For information about entering and exiting AT and Binary Command Modes, refer to the Command
Mode section.
3.1.1. AT Commands
To Send AT Commands (Using the ‘Terminal’ tab of the X-CTU Software)
Example: Utilize the 'Terminal' tab of the X-CTU Software to change the module's DT (Destination Address) parameter and save the new address to non-volatile memory. This example
requires the installation of Digi’s X-CTU Software and a serial connection to a PC.
Note: Do not send com‐
mands to the module
during flash program‐
ming (when parameters
are being written to the
module registry).
Wait for the “OK” sys‐
tem response that fol‐
lows the ATWR
command before enter‐
ing the next command
or use flow control.
Select the ‘Terminal’ tab of the X-CTU Software and enter the following command lines:
Method 1 (One line per command)
Send AT Command
+++
ATDT 
ATDT1A0D 
ATWR 
ATCN 
System Response
OK  (Enter into Command Mode)
{current value}  (Read Destination Address)
OK  (Modify Destination Address)
OK  (Write to non-volatile memory)
OK  (Exit Command Mode)
Method 2 (Multiple commands on one line)
Send AT Command
+++
ATDT 
ATDT1A0D,WR,CN 
System Response
OK  (Enter into Command Mode)
{current value}  (Read Destination Address)
OK  (Execute commands)
Note: When using X-CTU Software to program a module, PC com port settings must match the baud
(interface data rate), parity & stop bits parameter settings of the module. Use the 'Com Port Setup'
section of the “PC Settings” tab to configure PC com port settings to match those of the module.
3.1.2. Binary Commands
To Send Binary Commands
Example: Use binary commands to change the XBee module's destination address to 0x1A0D
and save the new address to non-volatile memory.
1.
RT Command must be set to "1" in AT Command Mode to enable binary programming.
2.
Assert CMD (Pin 16 is driven high). (Enter Binary Command Mode)
3.
Send Bytes (parameter bytes must be 2 bytes long):
(Send DT (Destination Address) Command)
00
(Least significant byte of parameter bytes
0D
(Most significant byte of parameter bytes)
1A
(Send WR (Write) Command)
08
De-assert CMD (Pin 16 is driven
(Exit Binary Command Mode)
4.
low)
Note: CTS is de-asserted high when commands are being executed. Hardware flow control must be
disabled as CTS will hold off parameter bytes.
© 2011 Digi International, Inc.
18
XBee‐PRO® XSC OEM RF Modules
3.2. Command Reference Table
Table 3‐01.
AT Commands (The RF Module expects numerical values in hexadecimal. ʺdʺ denotes decimal equivalent.)
AT
Command
Binary
Command
*AM
AT
Command Category
# Bytes
Returned
Factory
Default
AT Command Name
Range
0x3A (58d)
Auto-set MY
Networking & Security
0x05 (5d)
Guard Time After
0x02 – 0xFFFF [x 100 msec]
Command Mode Options
0x0A (10d)
Interface Data Rate
Standard baud rates:
0–6
Non-standard baud rates:
0x7D – 0xFFFF
Serial Interfacing
0x03 9600bps
BD
0x15 (21d)
BT
0x04 (4d)
Guard Time Before
2 – 0xFFFF [x 100 msec]
Command Mode Options
0x0A (10d)
CC
0x13 (19d)
Command Sequence Character
0x20 – 0x7F
Command Mode Options
0x2B (“+”)
CD
0x28 (40d)
DO3 Configuration
0-4
Serial Interfacing
CN
0x09 (9d)
Exit AT Command Mode
Command Mode Options
CS
0x1F (31d)
DO2 Configuration
0–4
Serial Interfacing
CT
0x06 (6d)
Command Mode Timeout
0x02 – 0xFFFF [x 100 msec]
Command Mode Options
0xC8 (200d)
RSSI level in dBm of the most recent
packet
0 - 0x70 [read-only]
Diagnostics
DB
DT
0x00 (0d)
Destination Address
0 – 0xFFFF
Networking
E0
0x0A (10d)
Echo Off
Command Mode Options
E1
0x0B (11d)
Echo On
Command Mode Options
ER
0x0F (15d)
Receive Error Count
0 – 0xFFFF
Diagnostics
FH
0x0D (13d)
Force Wake-up Initializer
Sleep (Low Power)
FL
0x07 (7d)
Software Flow Control
0–1
Serial Interfacing
FT
0x24 (36d)
Flow Control Threshold
0 – (DI buffer – 0x11) [bytes]
Serial Interfacing
varies
GD
0x10 (16d)
Receive Good Count
0 – 0xFFFF
Diagnostics
FR
Forces the module to Reset
(Special)
HP
0x11 (17d)
Hopping Channel
0–6
Networking
HT
0x03 (3d)
Time before Wake-up Initializer
0 – 0xFFFF [x 100 msec]
Sleep (Low Power)
0xFFFF
User set table: 0x10 - 0x7FFF
Read-only: 0x8000 – 0xFFFF
Networking
ID
0x27 (39d)
Module VID
LH
0x0C (12d)
Wake-up Initializer Timer
0 – 0xFF [x 100 msec]
Sleep (Low Power)
*MD
0x32 (50d)
RF Mode
0–4
Networking & Security
0xFFFF
MK
0x12 (18d)
Address Mask
0 – 0xFFFF
Networking
*MY
0x2A (42d)
Source Address
0 – 0xFFFF
Networking & Security
0xFFFF
NB
0x23 (35d)
Parity
0–5
Serial Interfacing
PC
0x1E (30d)
Power-up Mode
0–1
Command Mode Options
*PK
0x29 (41d)
RF Packet Size
0 - 0x100 [bytes]
Serial Interfacing
0x40 (64d)
*PL
0x3c (60d)
RF Power Level
0-4
(Special)
PW
0x1D (29d)
Pin Wake-up
0–1
Sleep (Low Power)
*RB
0x20 (32d)
Packetization Threshold
0 - 0x100 [bytes]
Serial Interfacing
0x01
RE
0x0E (14d)
Restore Defaults
(Special)
RN
0x19 (25d)
Delay Slots
0 – 0xFF [slots]
Networking
RO
0x21 (33d)
Packetization Timeout
0 – 0xFFFF [x 200 µsec]
Serial Interfacing
RP
0x22 (34d)
RSSI PWM Timer
0 - 0x7F [x 100 msec]
Diagnostics
RR
0x18 (24d)
Retries
0 – 0xFF
Networking
RS
0x1C (28d)
RSSI
0x06 – 0x36 [read-only]
Diagnostics
RT
0x16 (22d)
DI2 Configuration
0-2
Serial Interfacing
*RZ
0x2C (44d)
DI Buffer Size
[read-only]
Diagnostics
SB
0x36 (54d)
Stop Bits
0-1
Serial Interfacing
SH
0x25 (37d)
Serial Number High
0 – 0xFFFF [read-only]
Diagnostics
SL
0x26 (38d)
Serial Number Low
0 – 0xFFFF [read-only]
Diagnostics
SM
0x01 (1d)
Sleep Mode
0, 1, 3 - 8
Sleep (Low Power)
ST
0x02 (2d)
Time before Sleep
0x10 – 0xFFFF [x 100 msec]
Sleep (Low Power)
0x64 (100d)
© 2011 Digi International, Inc.
19
XBee‐PRO® XSC OEM RF Modules
SY
0x17 (23d)
Time before Initialization
0 – 0xFF [x 100 msec]
Networking
TR
0x1B (27d)
Transmit Error Count
0 – 0xFFFF
Diagnostics
TT
0x1A (26d)
Streaming Limit
0 – 0xFFFF [0 = disabled]
Networking
0xFFFF
VR
0x14 (20d)
Firmware Version
0 - 0xFFFF [read-only]
Diagnostics
0x08 (8d)
Write
(Special)
WR
0 (disabled)
NOTE: AT Commands issued without a parameter value are interpreted as queries and will return the currently stored parameter.
*Commands only supported on S3B hardware.
3.3. Command Descriptions
Commands in this section are listed alphabetically. Command categories are designated between
the “< >” symbols that follow each command title. Modules expect numerical values in
hexadecimal and those values are designated by a “0x” prefix.
Modules operating within the same network should contain the same firmware platform to ensure
the same AT Command parameters are supported.
AM (Auto-set MY) Command
Command Summary
AT Command: ATAM
Binary Command: 0x3A (58 decimal)
This command is only supported on S3B
modules.
Description
 AM Command
is used to automatically set the MY
(Source Address) parameter from the
factory-set module serial number. The
address is formed with bits 29, 28 and
13-0 of the serial number (in that
order).
AT (Guard Time After) Command
Command Summary
AT Command: ATAT
Binary Command: 0x05 (5 decimal)
Parameter Range:0x02 – 0xFFFF
[x 100 milliseconds]
Number of bytes returned: 2
Default Parameter Value: 0x0A (10
decimal)
Related Commands: BT (Guard Time
Before), CC (Command Sequence
Character)
Description
 AT
Command is used to set the time-ofsilence that follows the command
sequence character (CC Command). By
default, AT Command Mode will activate
after one second of silence.
Refer to the AT Commands section [p] to
view the default AT Command Mode
Sequence.
© 2011 Digi International, Inc.
20
XBee‐PRO® XSC OEM RF Modules
BD (Interface Data Rate) Command
Command Summary
AT Command: ATBD
Binary Command: 0x15 (21 decimal)
Parameter Range (Standard baud rates): 0
–6
(Non-standard baud rates): 0x7D –
0xFFFF (125d – 65535d)
Parameter
Value
BAUD (bps)
Configuration
1200
2400
4800
9600
19200
38400
57600
Number of bytes returned: 2
Default Parameter Value: Set to equal
module’s factory-set RF data rate.
Table 3‐02.
Description
 BD Command allows the user to adjust the
UART interface data rate and thus modify the rate at which
serial data is sent to the module. The new baud rate does not
take effect until the CN (Exit AT Command Mode) Command is
issued. The RF data rate is not affected by the BD Command.
Although most applications will only require one of the seven
standard baud rates, non-standard baud rates are also
supported.
Note: If the serial data rate is set to exceed the fixed RF data
rate of the module, flow control may need to be implemented
as described in the Pin Signals and Flow Control sections of this
manual.
Non-standard Interface Data Rates: When parameter values
outside the range of standard baud rates are sent, the closest
interface data rate represented by the number is stored in the
BD register. For example, a rate of 19200 bps can be set by
sending the following command line “ATBD4B00”. NOTE: When
using X-CTU Software, non-standard interface data rates can
only be set and read using the X-CTU ‘Terminal’ tab. Nonstandard rates are not accessible through the ‘Modem
Configuration’ tab.
When the BD command is sent with a non-standard interface
data rate, the UART will adjust to accommodate the requested
interface rate. In most cases, the clock resolution will cause the
stored BD parameter to vary from the parameter that was sent
(refer to the table below). Reading the BD command (send
“ATBD” command without an associated parameter value) will
return the value that was actually stored to the BD register.
Parameter Sent vs. Parameter Stored
BD Parameter Sent (HEX)
12C
E100
Interface Data Rate (bps)
1200
19,200
57600
300
57600
BD Parameter Stored (HEX)
12B
E883
BT (Guard Time Before) Command
Command Summary
AT Command: ATBT
Binary Command: 0x04 (4 decimal)
Parameter Range:2 – 0xFFFF
[x 100 milliseconds]
Default Parameter Value: 0x0A (10
decimal)
Number of bytes returned: 2
Related Commands: AT (Guard Time
After), CC (Command Sequence
Character)
Description
 BT
Command is used to set the DI pin
silence time that must precede the
command sequence character (CC
Command) of the AT Command Mode
Sequence. Refer to the AT Commands
section [p] to view the default AT
Command Mode Sequence.
© 2011 Digi International, Inc.
21
XBee‐PRO® XSC OEM RF Modules
CC (Command Sequence Character) Command
Command Summary
AT Command: ATCC
Binary Command: 0x13 (19 decimal)
Parameter Range: 0x20 – 0x7F
Default Parameter Value: 0x2B (ASCII “+”
sign)
Number of bytes returned: 1
Related Commands: AT (Guard Time
After), BT (Guard Time Before)
Description
 CC
Command is used to set the ASCII
character to be used between Guard
Times of the AT Command Mode
Sequence (BT+ CC + AT). The AT
Command Mode Sequence activates AT
Command Mode (from Idle Mode).
Refer to the AT Commands section [p] to
view the default AT Command Mode
Sequence.
CD (DO3 Configuration) Command
AT Command: ATCD
Binary Command: 0x28 (40 decimal)
Parameter Range: 0 – 3
Parameter
Value
Configuration
RX LED
Default high
Default low
(reserved)
Assert only when packet
addressed to module is sent
Description
 CD
Command is used to
define the behavior of
the DO3/RX LED line.
Default Parameter Value: 0
Number of bytes returned: 1
CN (Exit AT Command Mode) Command
Command Summary
AT Command: ATCN
Binary Command: 0x09 (9 decimal)
Description
 CN
Command is used to explicitly exit AT
Command Mode.
CS (DO2 Configuration) Command
Command Summary
AT Command: ATCS
Binary Command: 0x1F (31 decimal)
Parameter Range:0 – 4
Parameter
Value
Configuration
RS-232
flow control
RS-485 TX enable low
high
RS-485 TX enable high
low
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required:
4.27D
Description
 CS
Command is used to
select the behavior of
the DO2 pin signal.
This output can
provide RS-232 flow
control, control the TX
enable signal (for RS485 or RS-422
operations), or set the
default level for the I/O
line passing function.
By default, DO2
provides RS-232 CTS
(Clear-to-Send) flow
control.
© 2011 Digi International, Inc.
22
XBee‐PRO® XSC OEM RF Modules
CT (Command Mode Time out) Command
Command Summary
AT Command: ATCT
Binary Command: 0x06 (6 decimal)
Parameter Range:0x02 – 0xFFFF
[x 100 milliseconds]
Default Parameter Value: 0xC8 (200
decimal, 20 seconds)
Number of bytes returned: 2
Description
 CT
Command sets the amount of time
before AT Command Mode terminates
automatically. After a CT time of
inactivity, the module exits AT
Command Mode and returns to Idle
Mode. AT Command Mode can also be
exited manually using CN (Exit AT
Command Mode) Command.
DB (RSSI in dBm) Command
Command Summary
AT Command: ATDB
Binary Command: Not available
Parameter Range:00x00 to 0x70
[read-only]
Number of bytes returned: returned: 1
Related Commands: RS (RSSI Level)
Description
 DB command returns the
signal level of the last packet received in
dBm. This reading is useful for
determining range characteristics of the
Modules under various conditions of
noise and distance.
Once the command is issued, the
module will return the value in dBm.
0x32 (50d) = -50 dBm (strong signal),
and 0x64 (100d) = -100 dBm (weak
signal).
DT (Destination Address) Command
Command Summary
AT Command: ATDT
Binary Command: 0x00
Parameter Range:0 – 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: HP (Hopping
Channel), ID (Module VID), MK (Address
Mask)
Description
 DT Command is used to
set the networking address of a Module.
Modules use three network layers –
Vendor Identification Number (ATID),
Channels (ATHP), and Destination
Addresses (ATDT). DT Command
assigns an address to a module that
enables it to communicate only with
other modules having the same
addresses. All modules that share the
same Destination Address can
communicate freely with each other.
Modules in the same network with a
different Destination Address (than that
of the transmitter) will listen to all
transmissions to stay synchronized, but
will not send any of the data out their
serial ports.
E0 (Echo Off) Command
Command Summary
AT Command: ATE0
Binary Command: 0x0A (10 decimal)
Description
 E0
Command turns off character echo in AT
Command Mode. By default, echo is off.
© 2011 Digi International, Inc.
23
XBee‐PRO® XSC OEM RF Modules
E1 (Echo On) Command
Command Summary
AT Command: ATE1
Binary Command: 0x0B (11 decimal)
Description
 E1
Command turns on the echo in AT
Command Mode. Each typed character
will be echoed back to the terminal
when ATE1 is active. E0 is the default.
ER (Receive Error Count) Command
Command Summary
AT Command: ATER
Binary Command: 0x0F (15 decimal)
Parameter Range:0 – 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: GD (Receive Good
Count)
Description
 Set/Read the receiveerror. The error-count records the
number of packets partially received
then aborted on a reception error. This
value returns to 0 after a reset and is not
non-volatile (Value does not persist in
the module’s memory after a power-up
sequence). Once the “Receive Error
Count” reaches its maximum value (up
to 0xFFFF), it remains at its maximum
count value until the maximum count
value is explicitly changed or the
module is reset.
FH (Force Wake-up Initializer) Command
Command Summary
AT Command: ATFH
Binary Command: 0x0D (13 decimal)
Description
 FH Command is
used to force a Wake-up Initializer to be
sent on the next transmit. WR (Write)
Command does not need to be issued
with FH Command.
Use only with cyclic sleep modes active
on remote modules.
FL (Software Flow Control) Command
Command Summary
AT Command:
ATFL
Binary Command: 0x07 (7
decimal)
Parameter Range: 0 – 1
Parameter Value
Configuration
Disable software
flow control
Enable software
flow control
Default Parameter Value: 0
Number of bytes returned: 1
Description
 FL Command
is used to configure software flow
control. Hardware flow control is
implemented with the Module as
the DO2 pin (), which regulates
when serial data can be transferred
to the module. FL Command can be
used to allow software flow control
to also be enabled. XON character
used is 0x11 (17 decimal). XOFF
character used is 0x13 (19
decimal).
© 2011 Digi International, Inc.
24
XBee‐PRO® XSC OEM RF Modules
FR (Force Reset) Command
Command Summary
AT Command: ATFR
Binary Command: Not available
Description
 FR command is used in order
to reset the module through the UART.
The characters “OK” will be
returned and the module will reset
100ms
FT (Flow Control Threshold) Command
Command Summary
AT Command: ATFT
Binary Command: 0x24 (36 decimal)
Parameter Range:0 – (DI buffer size minus
0x11 bytes)
Default Parameter Value: DI Buffer size
minus 0x11 (17 decimal)
Number of bytes returned: 2
Minimum Firmware Version Required:
4.27B
Description
 Flow Control
Threshold - Set or read flow control
threshold. De-assert CTS and/or send
XOFF when FT bytes are in the UART
receive buffer. Re-assert CTS when less
than FT - 16 bytes are in the UART receive
buffer.
GD (Receive Good Count) Command
Command Summary
AT Command: ATGD
Binary Command: 0x10 (16 decimal)
Parameter Range:0 – 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: ER (Receive Error
Count)
Description
 Set/Read the count of
good received RF packets. Parameter
value is reset to 0 after every reset and is
not non-volatile (Value does not
persist in the module’s memory after a
power-up sequence). Once the
“Receive Good Count” reaches its
maximum value (up to 0xFFFF), it
remains at its maximum count value until
the maximum count value is
manually changed or the module is reset.
HP (Hopping Channel) Command
Command Summary
AT Command: ATHP
Binary Command: 0x11 (17 decimal)
Parameter Range:0 – 6
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: DT (Destination
Address), ID (Module VID), MK (Address
Mask)
Description
 HP Command is used to
set the module’s hopping channel
number. A channel is one of three layers
of addressing available to the
module. In order for modules to
communicate with each other, the
modules must have the same channel
number since each network uses a
different hopping sequence. Different
channels can be used to prevent
modules in one network from listening
to transmissions of another.
© 2011 Digi International, Inc.
25
XBee‐PRO® XSC OEM RF Modules
HT (Time before Wake-up Initializer) Command
Command Summary
AT Command: ATHT
Binary Command: 0x03 (3 decimal)
Parameter Range:0 – 0xFFFF
[x 100 milliseconds]
Default Parameter Value: 0xFFFF (means
that long wake-up initializer will not be
sent)
Number of bytes returned: 2
Related Commands: LH (Wake-up
Initializer Timer), SM (Sleep Mode), ST
(Time before Sleep)
Description
 If any modules within range are running
in a “Cyclic Sleep” setting, a wake-up initializer must be used
by the transmitting module for sleeping modules to remain
awake [refer to the LH (“Wake-up InitializerTimer”) Command].
When a receiving module in Cyclic Sleep wakes, it must detect
the wake-up initializer in order to remain awake and
receive data. The value of HT Parameter tells the transmitter,
“After a period of inactivity (no transmitting or receiving)
lasting HT amount of time, send a long wake-up initializer”. HT
Parameter should be set to match the inactivity time out
[specified by ST (Time before Sleep) Command]
used by the receiver(s). From the receiving module perspective,
after HT time elapses and the inactivity
time out [ST Command] is met, the receiver goes into cyclic
sleep. In cyclic sleep, the receiver wakes once per sleep interval
to check for a wakeup initializer. When a wake-up initializer is
detected, the module will stay awake to receive data. The
wake-up initializer must be longer than the
cyclic sleep interval to ensure that sleeping modules detect
incoming data. When HT time elapses, the transmitter then
knows that it needs to send a long Wake-up Initializer for all
receivers to be able to remain awake and
receive the next transmission. Matching HT to the time
specified by ST on the receiving module guarantees that all
receivers will detect the next transmission.
ID (Modem VID) Command
Command Summary
AT Command: ATID
Binary Command: 0x27 (39 decimal)
Parameter Range (user-set table) 0x10 0x7FFFF
(Factory-set and read-only) 0x8000 –
0xFFFF
Number of bytes returned: 2
Description
 Set/Read the “Vendor
Identification Number”. Only modems
with matching IDs can communicate
with each other. Modules with nonmatching
VIDs will not receive unintended data
transmission.
© 2011 Digi International, Inc.
26
XBee‐PRO® XSC OEM RF Modules
LH (Wake-up Initializer Timer) Command
Command Summary
AT Command: ATLH
Binary Command: 0x0C (12 decimal)
Parameter Range:0 – 0xFF
[x 100 milliseconds]
Default Parameter Value: 1
Number of bytes returned: 1
Related Commands: HT (Time before
Wake-up Initializer), SM (Sleep Mode), ST
(Time before Sleep)
Description
 LH Command
adjusts the duration of time for which
the RF initializer is sent.
When receiving modules are put into
Cyclic Sleep Mode, they power-down
after a period of inactivity [specified by
ST (Time before Sleep) Command] and
will periodically awaken and listen
for transmitted data. In order for the
receiving modules to remain awake, they
must detect~35ms of the wake-up
initializer. LH Command must be used
whenever a receiver is operating in
Cyclic Sleep Mode. This lengthens
the Wake-up Initializer to a specific
amount of time (in tenths of a second).
The Wake-up Initializer Time must be
longer than the cyclic sleep time that is
determined by SM (Sleep Mode)
Command. If the wake-up initializer
time were less than the Cyclic Sleep
interval, the connection would be at risk
of missing the wake-up initializer
transmission. Refer to Figures 3.1 & 3.2
of the SM Command description to view
diagrams of correct and incorrect
configurations. The images help
visualize the importance that the value
of LH be greater than the value of SM.
MD (RF Mode) Command
Command Summary
AT Command: ATMD
Binary Command: 0x32 (50 decimal)
Parameter Range: 0 – 4
Description
 The MD
command is used to select/read the RF
Mode (Peer-to-peer, Multi-Stream or
Repeater Modes) of the module.
Multi-Streaming Mode enables exclusive
Parameter
Configuration
connections in point-to-multipoint
networks. Refer to the Multi-Streaming
Peer-to-Peer
(transparent operation) Mode section [p43] for more information
regarding how these parameter values
Multi-Steam Base
affect other parameter values.
Multi-Steam Remote Repeater Mode enables longer range via
an intermediary module. When MD=3,
Repeater & End Node
the module will act as a “store and
forward” repeater. Any packets not
End Node
addressed to this node will be repeated.
Default Parameter Value: 0
A Repeater End Node (MD=4) handles
Number of bytes returned: 1
repeated messages, but will not forward
Related Commands: CB (Connection
the data over-the-air. Refer to the
Duration Time out), CE (Connection
Repeater Mode section [p38] for more
Inactivity Time out), CM (Connection
information.
Message), DC (Disconnect)
This command is only supported on S3B
modules.
© 2011 Digi International, Inc.
27
XBee‐PRO® XSC OEM RF Modules
MK (Address Mask) Command
Command Summary
AT Command: ATMK
Binary Command: 0x12 (18 decimal)
Parameter Range:0 – 0xFFFF
Default Parameter Value: 0xFFFF
(Destination address (DT parameter) of
the transmitting module must exactly
match the destination address of the
receiving module.)
Number of bytes returned: 2
Related Commands: DT (Destination
Address), HP (Hopping Channel), ID
(Module VID)
Description
 MK Command is used to
set/read the Address Mask.
All data packets contain the Destination
Address of the transmitting module.
When an RF data packet is received, the
transmitter’s Destination Address is
logically “ANDed” (bitwise) with the
Address Mask of the receiver. The
resulting value must match the
Destination Address or the
Address Mask of the receiver for the
packet to be received and sent out the
module’s DO serial port. If the “ANDed”
value does not match either the
Destination Address or the Address
Mask of the receiver, the packet is
discarded. (All “0” values are treated as
“irrelevant” values and are ignored.)
MY (Source Address) Command
Command Summary
AT Command: ATMY
Binary Command: 0x2A (42 decimal)
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0xFFFF
(Disabled – the DT (Destination Address)
parameter serves as both source and
destination address.)
Number of bytes returned: 2
Related Commands: DT (Destination
Address), HP (Hopping Channel), ID
(Modem VID), MK (Address Mask), AM
(Auto-set MY)
This command is only supported on S3B
modules.
Description
 Set/Read the
source address of the module.
Refer to the Addressing section [p36] of
the RF Communication Modes chapter
for more information.
NB (Parity) Command
Command Summary
AT Command: ATNB
Binary Command: 0x23 (35 decimal)
Parameter Range:0 – 4 (S3 Hardware)
0-5 (S3B Hardware)
Parameter
Value
Configuration
Description

Select/Read parity
settings for UART
communications.
8-bit (no parity or
7-bit (any parity)
8-bit even
8-bit odd
8-bit mark
8-bit space
9-bit data (S3B Hardware)
Default Parameter Value: 0
Number of bytes returned: 1
© 2011 Digi International, Inc.
28
XBee‐PRO® XSC OEM RF Modules
PC (Power-up to AT Mode) Command
Command Summary
AT Command: ATPC
Binary Command: 0x1E (30 decimal)
Parameter Range:0 – 1
Parameter
Value
Configuration
Power-up to Idle Mode
Power-up to
AT Command Mode
Default Parameter Value: 0
Number of bytes returned: 1
Description
 PC
Command allows the
module to power-up
directly into AT
Command Mode from
reset or power-on. If
PC Command is
enabled with SM
Parameter set to 1, DI3
(pin 9) can be used to
enter the
module into AT
Command Mode. When
the DI3 pin is deasserted (low),
the module will wakeup in AT Command
Mode. This behavior
allows module
DTR emulation.
PK (RF Packet Size) Command
Command Summary
AT Command: ATPK
Binary Command: 0x29 (41 decimal)
Parameter Range: 0 – 0x100 [Bytes]
Default Parameter Value: 0x40 (64
decimal)
Number of bytes returned: 2
Related Commands: RB (Packetization
Threshold), RO (Packetization Time out)
This command is only supported on S3B
modules.
Description
 Set/Read the
maximum size of the RF packets sent
out a transmitting module. The
maximum packet size can be used along
with the RB and RO parameters to
implicitly set the channel dwell time.
Changes to this parameter may have a
secondary effect on the RB (Packet
Control Characters) parameter. RB must
always be less than or equal to PK. If PK
is changed to a value less than the
current value of RB, RB is automatically
lowered to be equal to PK.
PL (Module Power Level) Command
Command Summary
AT Command: ATPL
Binary Command: 0x3C (60 decimal)
Parameter Range:0 – 4
Parameter
Value
Configuration
Description
 Set/Read the power level at which the RF
module transmits conducted power. This command is only
supported on S3B hardware. Power level 4 is calibrated and the
other power levels are approximate.
+7.0 dBm
+15.0dBm
+18.0dBm
+21.0dBm
+24.0 dBm
Default Parameter Value: 4
Number of bytes returned: 1
This command is only supported on S3B
hardware
© 2011 Digi International, Inc.
29
XBee‐PRO® XSC OEM RF Modules
PW (Pin Wake-up) Command
Command Summary
AT Command: ATPW
Binary Command: 0x1D (29 decimal)
Parameter Range:0 – 1
Parameter
Value
Configuration
Disabled
Enabled
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: SM (Sleep Mode), ST
(Time before Sleep)
Description
 Under normal operation, a module in
Cyclic Sleep Mode cycles from an active state to a low-power
state at regular intervals until data is ready to be received. If
the PW Parameter is set to 1, SLEEP (pin 2) can be used to wake
the module from Cyclic Sleep. If the SLEEP pin
is de-asserted (low), the module will be fully operational and
will not go into Cyclic Sleep. Once SLEEP is asserted, the
module will remain active for the period of time specified by ST
(Time before Sleep) Command, and will return to Cyclic Sleep
Mode (if no data is ready to be transmitted). PW
Command is only valid if Cyclic Sleep has been enabled.
RB (Packetization Threshold) Command
Command Summary
AT Command: ATRB
Binary Command: 0x20 (32 decimal)
Parameter Range: 0 – 0x100 [Bytes]
(Maximum value equals the current value
of PK Parameter (up to 0x100 HEX (800
decimal))
Default Parameter Value: 1
Number of bytes returned: 2
Related Commands: PK (RF Packet Size),
RO (Packetization Time out)
This command is only supported on S3B
modules.
Description
 RF transmission will
commence when data is in the DI Buffer
and either of the following criteria are
met:
• RO times out on the UART receive lines
(ignored if RO = 0)
• RB characters have been received by
the UART (ignored if RB = 0)
If PK is lowered below the value of RB; RB
is automatically lowered to match PK.
Note: RB and RO criteria only apply to
the first packet of a multi-packet
transmission. If data remains in the DI
Buffer after the first packet,
transmissions will continue in streaming
manner until there is no data left in the
DI Buffer (UART receive buffer).
RE (Restore Defaults) Command
Command Summary
AT Command: ATRE
Binary Command: 0x0E (14 decimal)
Description
 RE Command restores all
configurable parameters to factory
default settings. However, RE Command
will not write the default values to
non-volatile (persistent) memory. Unless
the WR (Write) Command is
issued after the RE command, the
default settings will not be saved in the
event of module reset or power-down.
© 2011 Digi International, Inc.
30
XBee‐PRO® XSC OEM RF Modules
RN (Delay Slots) Command
Command Summary
AT Command: ATRN
Binary Command: 0x19 (25 decimal)
Parameter Range:0 – 0xFF [slots]
Default Parameter Value: 0 (no delay slots
inserted)
Number of bytes returned: 1
Description
 RN Command is only
applicable if retries have been
enabled [RR (Retries) Command], or if
forced delays will be inserted into
a transmission [refer to TT (Streaming
Limit) Command]. RN Command is
used to adjust the time delay that the
transmitter inserts before attempting
to resend a packet. If the transmitter
fails to receive an acknowledgement
after sending a packet, it will insert a
random number of delay slots
(ranging from 0 to (RN minus 1)) before
attempting to resend the packet.
Each delay slot lasts for a period of
38ms.
If two modules attempted to transmit at
the same time, the random time
delay after packet failure would allow
one of the two modules to transmit
the packet successfully, while the other
would wait until the channel
opens up to begin transmission.
RO (Packetization Time out) Command
Command Summary
AT Command: ATRO
Binary Command: 0x21 (33 decimal)
Parameter Range:0 – 0xFFFF [x 200 µs]
Default Parameter Value: 0
Number of bytes returned: 2
Description
 RO Command is used
to specify/read the time of
silence (no bytes received) after which
transmission begins. After a serial
byte is received and if no other byte is
received before the RO time out,
the transmission will start.
RP (RSSI PWM Timer) Command
Command Summary
AT Command: ATRP
Binary Command: 0x22 (34 decimal)
Parameter Range:0 - 0x7F
[x 100 milliseconds]
Default Parameter Value: 0 (disabled)
Number of bytes returned: 1
Description
 RP Command is used to
enable a PWM (“Pulse Width Modulation”)
output on the Config pin which is
calibrated to show the level the
received RF signal is above the sensitivity
level of the module. The PWM
pulses vary from zero to 95 percent. Zero
percent means the received RF
signal is at or below the published
sensitivity level of the module. The
following
table shows levels above sensitivity and
PWM values.
The total period of the PWM output is
8.32 ms. There are 40 steps in the
PWM output and therefore the minimum
step size is 0.208 ms.
© 2011 Digi International, Inc.
31
XBee‐PRO® XSC OEM RF Modules
Table 3‐03.
PWM Chart
dBm above Sensitivity
10
20
30
PWM percentage
(high period / total period)
47.5 %
62.5 %
77.5 %
A non-zero value defines the time that the PWM output will be active with the RSSI value of the
last received RF packet. After the set time when no RF packets are received, the PWM output will
be set low (0 percent PWM) until another RF packet is received. The PWM output will also be set
low at power-up. A parameter value of 0xFF permanently enables the PWM output and it will
always reflect the value of the last received RF packet.
PWM output shares the Config input pin. When the module is powered, the Config pin will be an
input. During the power-up sequence, the Config pin will be read to determine whether the module
is going into AT Command Mode. After this, if RP parameter is a non-zero value, the Config pin will
be configured as an output and set low until the first RF packet is received. With a non-zero RP
parameter, the Config pin will be an input for RP ms after power up.
RZ (DI Buffer Size) Command
Command Summary
AT Command: ATRZ
Binary Command: 0x2C (44 decimal)
Parameter Range:Read-only
Number of bytes returned: 1
This command is only supported on S3B
modules.
Description
 The RZ command is used
to read the size of the DI buffer (UART RX
(Receive)).
Note: The DO buffer size can be
determined by multiplying the DI buffer
size by 1.5.
RR (Retries) Command
Command Summary
AT Command: ATRR
Binary Command: 0x18 (24 decimal)
Parameter Range:0 – 0xFF
Default Parameter Value: 0 (disabled)
Number of bytes returned: 1
Description
Networking> RR Command specifies the
number of retries that can be sent
for a given RF packet. Once RR Command
is enabled (set to a non-zero
value), RF packet acknowledgements and
retries are enabled. After transmitting
a packet, the transmitter will wait to
receive an acknowledgement
from a receiver. If the acknowledgement
is not received in the period of
time specified by the RN (Delay Slots)
Command, the transmitter will transmit
the original packet again. The packet will
be transmitted repeatedly
until an acknowledgement is received or
until the packet has been sent RR
times.
Note: For retries to work correctly, all
modules in the system must have
retries enabled.
© 2011 Digi International, Inc.
32
XBee‐PRO® XSC OEM RF Modules
RS (RSSI) Command
Command Summary
AT Command: ATRS
Binary Command: 0x1C (28 decimal)
Parameter Range: 0x06 – 0x36 [readonly]
Number of bytes returned: 1
Description
 RS Command returns the
signal level of the last packet
received. This reading is useful for
determining range characteristics of the
modules under various conditions of
noise and distance.
Once the command is issued, the
module will return a value between 0x6
and 0x36 where 0x36 represents a very
strong signal level and 0x4 indicates
a low signal level.
RT (DI2 Configuration) Command
Command Summary
AT Command: ATRT
Binary Command: 0x16 (22 decimal)
Parameter Range:0 – 2
Parameter
Value
Configuration
disabled
Enable Binary Programming
Enable
Default Parameter Value: 0
Number of bytes returned: 1
Flow Control
Description
 RT
command is used to
dictate the behavior of
the
DI2/RTS/CMD line. RT
Command must be
issued to enable RTS
flow control
or binary
programming.
SB (Stop Bits) Command
Command Summary
AT Command: ATSB
Binary Command: 0x36 (54 decimal)
Parameter Range:0 – 1
Parameter
Value
Configuration
Description
SB Command is used to
set/read the number of
stop bits in the data
packets.
1 stop bits
2 stop bits
Default Parameter Value: 0
Number of bytes returned: 1
SH (Serial Number High) Command
Command Summary
AT Command: ATSH
Binary Command: 0x25 (37 decimal)
Parameter Range:0 – 0xFFFF [read-only]
Number of bytes returned: 2
Related Commands: SL (Serial Number
Low)
Description
 Read the serial number
high word of the module.
© 2011 Digi International, Inc.
33
XBee‐PRO® XSC OEM RF Modules
SL (Serial Number Low) Command
Command Summary
AT Command: ATSL
Binary Command: 0x26 (38 decimal)
Parameter Range:0 – 0xFFFF [read-only]
Number of bytes returned: 2
Related Commands: SH (Serial Number
High)
Description
 Read the serial number
low word of the module.
SM (Sleep Mode) Command
Command Summary
AT Command: ATSM
Binary Command: 0x01
Parameter Range:0,1 3-8
Parameter
Value
Configuration
Disabled
Pin Sleep
Cyclic 0.5 second sleep
(Module wakes every 0.5
seconds)
Cyclic 1.0 second sleep
Cyclic 2.0 second sleep
Cyclic 4.0 second sleep
Cyclic 8.0 second sleep
Cyclic 16.0 second sleep
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands:
Description
 SM Command is used to adjust
Sleep Mode settings. By default, Sleep Mode is disabled and the
module remains continually active. SM Command allows the
module to run in a lower-powerstate and be configured in one
of eight settings. Cyclic Sleep settings wake the module after
the amount of time designated
by SM Command. If the module detects a wake-up initializer
during the time it is awake, it will synchronize with the
transmitter and start receiving data after the wake-up
initializer runs its duration. Otherwise, it
returns to Sleep Mode and continue to cycle in and out of
inactivity until the Wake-up Initializer is detected. If a Cyclic
Sleep setting is chosen, the ST, LH and HT parameters must
also be set as described in the “Sleep
Mode” section of this manual.
For Pin Sleep – PC (Power-up Mode), PW
(Pin Wake-up)
For Serial Port Sleep – ST (Time before
Sleep)
For Cyclic Sleep – ST (Time before Sleep),
LH (Wake-up Initializer Timer), HT (Time
Before Wake-up Initializer), PW (Pin Wakeup)
ST (Time before Sleep) Command
Command Summary
AT Command: ATST
Binary Command: 0x02
Parameter Range:0x10 – 0xFFFF
[x 100 milliseconds]
Default Parameter Value: 0x64 (100
decimal)
Number of bytes returned: 2
Related Commands: SM (Sleep Mode), LH
(Wake-up Initializer Timer), HT (Time
before Wake-up Initializer)
Description
 ST
Command sets the period of time (in
tenths of seconds) in which the module
remains inactive before entering
into Sleep Mode. For example, if the ST
Parameter is set to 0x64 (100
decimal), the module will enter into
Sleep mode after 10 seconds of
inactivity
(no transmitting or receiving). This
command can only be used if
Cyclic Sleep or Serial Port Sleep Mode
settings have been selected using
SM (Sleep Mode) Command.
© 2011 Digi International, Inc.
34
XBee‐PRO® XSC OEM RF Modules
SY (Time before Initialization) Command
Command Summary
AT Command: ATSY
Binary Command: 0x17 (23 decimal)
Parameter Range:0 – 0xFF
[x 100 milliseconds]
Default Parameter Value: 0 (Disabled channel initialization information is sent
with each RF packet.)
Number of bytes returned: 1
Description
 SY Command keeps a communication channel
open as long as module transmits or receives before the active
connection expires. It can be used to reduce latency in a query/
response sequence and should be set 100 ms longer than the
delay between transmissions. This command allows multiple
Modules to share a hopping channel
for a given amount of time after receiving data. By default, all
packets include an RF initializer that contains channel
information used to synchronize any listening receivers to the
transmitter’s hopping pattern. Once a new module comes
within range, it is able to instantly synchronize to the
transmitter and start receiving data. If no new modules are
introduced into the system, the synchronization information
becomes redundant once modules
have become synchronized.
SY Command allows the modules to remove this information
from the RF Initializer after the initial synchronization. For
example, changing the SY Parameter to 0x14 (20 decimal)
allows all modules to remain in sync for 2
seconds after the last data packet was received.
Synchronization information is not re-sent unless transmission
stops for more than 2 seconds. This command allows
significant savings in packet transmission time.
Warning: Not recommended for use in an interference-prone
environment. Interference can break up the session and the
communications channel will not be available again until SY
time expires. With SY set to zero, the channel session is opened
and closed with each transmission - resulting in a more robust
link with more latency.
TR (Transmit Error Count) Command
Command Summary
AT Command: ATTR
Binary Command: 0x1B (27 decimal)
Parameter Range:0 – 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: RR (Retries)
Description
 TR Command records the
number of retransmit failures.
This number is incremented each time a
packet is not acknowledged within
the number of retransmits specified by
the RR (Retries) Command. It
therefore counts the number of packets
that were not successfully received
and have been dropped.
The TR Parameter is not non-volatile and
will therefore be reset to zero
each time the module is reset.
© 2011 Digi International, Inc.
35
XBee‐PRO® XSC OEM RF Modules
TT (Streaming Limit) Command
Command Summary
AT Command: ATTT
Binary Command: 0x1A (26 decimal)
Parameter Range:0 – 0xFFFF (0 =
disabled)
Default Parameter Value: 0xFFFF (65535
decimal)
Number of bytes returned: 2
Related Commands: RN (Delay Slots)
Description
 TT Command defines a
limit on the number of bytes that can
be sent out before a random delay is
issued. TT Command is used to simulate
full-duplex behavior.
If a module is sending a continuous
stream of RF data, a delay is inserted
which stops its transmission and allows
other modules time to transmit
(once it sends number of bytes specified
by TT Command). Inserted random
delay lasts between 1 & ‘RN + 1’ delay
slots, where each delay slot
lasts 38 ms.
© 2011 Digi International, Inc.
36
XBee‐PRO® XSC OEM RF Modules
Appendix A: Agency Certifications
FCC (United States) Certification
The XBee-PRO® XSC OEM RF Module complies with Part 15 of the FCC rules and regulations.
Compliance with the labeling requirements, FCC notices and antenna usage guidelines is required.
In order to operate under Digi’s FCC Certification, OEMs/integrators must comply with the
following regulations:
1.
The system integrator must ensure that the text provided with this device [Figure A-01] is
placed on the outside of the final product and within the final product operation manual.
2.
The XBee-PRO® XSC OEM RF Module may only be used with antennas that have been
tested and approved for use with this module Refer to to Table A-1.
Labeling Requirements
WARNING: The Original Equipment Manufacturer (OEM) must ensure that FCC labeling
requirements are met. This includes a clearly visible label on the outside of the final
product enclosure that displays the text shown in the figure below.
Figure A‐01. Required FCC Label for OEM products containing the XBee‐PRO® XSC OEM RF Module.
XBEE PRO S3
Contains FCC ID: MCQ-XBEEXSC
The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any interference received, including interference that may cause undesired operation.
OR
XBEE PRO S3B
Contains FCC ID: MCQ-XBPS3B
The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any interference received, including interference that may cause undesired operation.
FCC Notices
IMPORTANT: The XBee-PRO® XSC OEM RF Module has been certified by the FCC for use with
other products without any further certification (as per FCC section 2.1091). Modifications not
expressly approved by Digi could void the user's authority to operate the equipment.
IMPORTANT: OEMs must test final product to comply with unintentional radiators (FCC section
15.107 & 15.109) before declaring compliance of their final product to Part 15 of the FCC Rules.
IMPORTANT: The RF module has been certified for remote and base radio applications. If the
module will be used for portable applications, the device must undergo SAR testing.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
© 2011 Digi International, Inc.
37
XBee‐PRO® XSC OEM RF Modules
interference by one or more of the following measures: Re-orient or relocate the receiving
antenna, Increase the separation between the equipment and receiver, Connect equipment and
receiver to outlets on different circuits, or Consult the dealer or an experienced radio/TV technician
for help.
Limited Modular Approval
This is an RF module approved for Limited Modular use operating as a mobile transmitting device
with respect to section 2.1091 and is limited to OEM installation for Mobile and Fixed applications
only. During final installation, end-users are prohibited from access to any programming
parameters. Professional installation adjustment is required for setting module power and antenna
gain to meet EIRP compliance for high gain antenna(s).
Final antenna installation and operating configurations of this transmitter including antenna gain
and cable loss must not exceed the EIRP of the configuration used for calculating MPE. Grantee
(Digi) must coordinate with OEM integrators to ensure the end-users and installers of products
operating with the module are provided with operating instructions to satisfy RF exposure
requirements.
The FCC grant is valid only when the device is sold to OEM integrators. Integrators are instructed
to ensure the end-user has no manual instructions to remove, adjust or install the device.
FCC-approved Antennas
WARNING: This device has been tested with Reverse Polarity SMA connectors with the
antennas listed in the tables of this section. When integrated into OEM products, fixed
antennas require installation preventing end-users from replacing them with nonapproved antennas. Antennas not listed in the tables must be tested to comply with FCC
Section 15.203 (unique antenna connectors) and Section 15.247 (emissions).
Fixed Base Station and Mobile Applications
Digi RF Modules are pre-FCC approved for use in fixed base station and mobile applications. When
the antenna is mounted at least 20cm (8") from nearby persons, the application is considered a
mobile application.
Portable Applications and SAR Testing
When the antenna is mounted closer than 20cm to nearby persons, then the application is
considered “portable” and requires an additional test be performed on the final product. This test
is called Specific Absorption Rate (SAR) testing and measures the emissions from the module and
how they affect the person.
RF Exposure
This statement must be included as a CAUTION statement in OEM product manuals.
WARNING: This equipment is approved only for mobile and base station transmitting
devices. Antenna(s) used for this transmitter must be installed to provide a separation
distance of at least 20 cm from all persons and must not be co-located or operating in
conjunction with any other antenna or transmitter.
IC (Industry Canada) Certification
Labeling requirements for Industry Canada are similar to those of the FCC. A clearly visible label
on the outside of the final product enclosure must display one of the following text:
For XBEE PRO S3 Contains Model: XBEEXSC, IC: 1846A-XBEEXSC
OR
For XBEEPRO S3B Contains Model: XBPS3B, IC: 1846A-XBPS3B
Integrator is responsible for its product to comply with IC ICES-003 & FCC Part 15, Sub. B Unintentional Radiators. ICES-003 is the same as FCC Part 15 Sub. B and Industry Canada accepts
FCC test report or CISPR 22 test report for compliance with ICES-003.
© 2011 Digi International, Inc.
38
XBee‐PRO® XSC OEM RF Modules
Transmitter Antennas
This device has been designed to operate with the antennas listed below, and having a maximum
gain of 15.1 dB. Antennas not included in this list or having a gain greater than 15.1 dB are strictly
prohibited for use with this device. The required antenna impedance is 50 ohms.
Operation is subject to the following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including interference that may cause undesired
operation of the device.
To reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotopically radiated power (e.i.r.p.) is not more than that permitted for
successful communication
Antenna Options: 900 MHz Antenna Listings
Table A-01. Antennas approved for use with the XBee-PRO XSC OEM RF Module
Type
Connector
Gain
Application
Cable Loss or
Power Reduction
for S3B Radio
A09-F0
Fiberglass Base
RPN
0 dBi
Fixed
0dB
A09-F1
Fiberglass Base
RPN
1.0 dBi
Fixed
0dB
A09-F2
Fiberglass Base
RPN
2.1 dBi
Fixed
0dB
A09-F3
Fiberglass Base
RPN
3.1 dBi
Fixed
0dB
A09-F4
Fiberglass Base
RPN
4.1 dBi
Fixed
0dB
A09-F5
Fiberglass Base
RPN
5.1 dBi
Fixed
0dB
A09-F6
Fiberglass Base
RPN
6.1 dBi
Fixed
0dB
A09-F7
Fiberglass Base
RPN
7.1 dBi
Fixed
0dB
A09-F8
Fiberglass Base
RPN
8.1 dBi
Fixed
0dB
Part Number
Omni-directional antennas
A09-F9
Base Station
RPSMAF
9.2dBi
Fixed
0dB
A09-W7
Wire Base Station
RPN
7.1 dBi
Fixed
0dB
A09-F0
Fiberglass Base
RPSMA
0 dBi
Fixed
0dB
A09-F1
Fiberglass Base
RPSMA
1.0 dBi
Fixed
0dB
A09-F2
Fiberglass Base
RPSMA
2.1 dBi
Fixed
0dB
A09-F3
Fiberglass Base
RPSMA
3.1 dBi
Fixed
0dB
A09-F4
Fiberglass Base
RPSMA
4.1 dBi
Fixed
0dB
A09-F5
Fiberglass Base
RPSMA
5.1 dBi
Fixed
0dB
A09-F6
Fiberglass Base
RPSMA
6.1 dBi
Fixed
0dB
A09-F7
Fiberglass Base
RPSMA
7.1 dBi
Fixed
0dB
A09-F8
Fiberglass Base
RPSMA
8.1 dBi
Fixed
0dB
A09-M7
Base Station
RPSMAF
7.2dBi
Fixed
0dB
A09-W7SM
Wire Base Station
RPSMA
7.1 dBi
Fixed
0dB
A09-F0TM
Fiberglass Base
RPTNC
0 dBi
Fixed
0dB
A09-F1TM
Fiberglass Base
RPTNC
1.0 dBi
Fixed
0dB
A09-F2TM
Fiberglass Base
RPTNC
2.1 dBi
Fixed
0dB
A09-F3TM
Fiberglass Base
RPTNC
3.1 dBi
Fixed
0dB
A09-F4TM
Fiberglass Base
RPTNC
4.1 dBi
Fixed
0dB
A09-F5TM
Fiberglass Base
RPTNC
5.1 dBi
Fixed
0dB
A09-F6TM
Fiberglass Base
RPTNC
6.1 dBi
Fixed
0dB
A09-F7TM
Fiberglass Base
RPTNC
7.1 dBi
Fixed
0dB
A09-F8TM
Fiberglass Base
RPTNC
8.1 dBi
Fixed
0dB
A09-W7TM
Wire Base Station
RPTNC
7.1 dBi
Fixed
0dB
© 2011 Digi International, Inc.
39
XBee‐PRO® XSC OEM RF Modules
A09-HSM-7
Straight half-wave
RPSMA
3.0 dBi
Fixed / Mobile
0dB
A09-HASM-675
Articulated half-
RPSMA
2.1 dBi
Fixed / Mobile
0dB
A09-HABMM-P6I
Articulated half-
MMCX
2.1 dBi
Fixed / Mobile
0dB
A09-HABMM-6-P6I
Articulated half-
MMCX
2.1 dBi
Fixed / Mobile
0dB
A09-HBMM-P6I
Straight half-wave
MMCX
2.1 dBi
Fixed / Mobile
0dB
A09-HRSM
Right angle half-
RPSMA
2.1 dBi
Fixed
0dB
A09-HASM-7
Articulated half-
RPSMA
2.1 dBi
Fixed
0dB
A09-HG
Glass mounted
RPSMA
2.1 dBi
Fixed
0dB
A09-HATM
Articulated half-
RPTNC
2.1 dBi
Fixed
0dB
A09-H
Half-wave dipole
RPSMA
2.1 dBi
Fixed
0dB
A09-HBMMP6I
A09-QBMMP6I
MMCX
MMCX
2.1dBi
1.9 dBi
Mobile
Mobile
0dB
0dB
Integrated
1.9 dBi
Mobile
0dB
29000187
1/2 wave antenna
1/4 wave antenna
1/4 wave integrated
wire antenna
Helical
Integrated
-2.0 dBi
Fixed/Mobile
0dB
A09-QW
Quarter-wave wire
Permanent
1.9 dBi
Fixed / Mobile
0dB
A09-QRAMM
3 “Quarter-wave
MMCX
2.1 dBi
Fixed / Mobile
0dB
A09-QI
A09-QSM-3
Quarter-wave
RPSMA
1.9 dBi
Fixed / Mobile
0dB
A09-QSM-3H
Heavy duty quarter-
RPSMA
1.9 dBi
Fixed / Mobile
0dB
A09-QBMM-P6I
Quarter-wave w/ 6”
MMCX
1.9 dBi
Fixed / Mobile
0dB
A09-QHRN
Miniature Helical
Permanent
-1 dBi
Fixed / Mobile
0dB
A09-QHSN
Miniature Helical
Permanent
-1 dBi
Fixed / Mobile
0dB
A09-QHSM-2
2” Straight
RPSMA
1.9 dBi
Fixed / Mobile
0dB
A09-QHRSM-2
2" Right angle
RPSMA
1.9 dBi
Fixed / Mobile
0dB
A09-QHRSM-170
1.7" Right angle
RPSMA
1.9 dBi
Fixed / Mobile
0dB
A09-QRSM-380
3.8" Right angle
RPSMA
1.9 dBi
Fixed / Mobile
0dB
A09-QAPM-520
5.2” Articulated
Permanent
1.9 dBi
Fixed / Mobile
0dB
A09-QSPM-3
3” Straight screw
Permanent
1.9 dBi
Fixed / Mobile
0dB
A09-QAPM-3
3” Articulated screw
Permanent
1.9 dBi
Fixed / Mobile
0dB
A09-QAPM-3H
3” Articulated screw
Permanent
1.9 dBi
Fixed / Mobile
0dB
A09-DPSM-P12F
omni directional
RPSMA
3.0 dBi
Fixed
0dB
A09-D3NF-P12F
omni directional
RPN
3.0 dBi
Fixed
0dB
A09-D3SM-P12F
omni directional w/
RPSMA
3.0 dBi
Fixed
0dB
A09-D3PNF
omni directional
RPN
3.0 dBi
Fixed
0dB
A09-D3TM-P12F
omni directional w/
RPTNC
3.0 dBi
Fixed
0dB
A09-D3PTM
omni directional
RPTNC
3.0 dBi
Fixed
0dB
A09-M0SM
Mag Mount
RPSMA
0 dBi
Fixed
0dB
A09-M2SM
Mag Mount
RPSMA
2.1 dBi
Fixed
0dB
A09-M3SM
Mag Mount
RPSMA
3.1 dBi
Fixed
0dB
A09-M5SM
Mag Mount
RPSMA
5.1 dBi
Fixed
0dB
A09-M7SM
Mag Mount
RPSMA
7.1 dBi
Fixed
0dB
A09-M8SM
Mag Mount
RPSMA
8.1 dBi
Fixed
0dB
A09-M0TM
Mag Mount
RPTNC
0 dBi
Fixed
0dB
A09-M2TM
Mag Mount
RPTNC
2.1 dBi
Fixed
0dB
A09-M3TM
Mag Mount
RPTNC
3.1 dBi
Fixed
0dB
A09-M5TM
Mag Mount
RPTNC
5.1 dBi
Fixed
0dB
A09-M7TM
Mag Mount
RPTNC
7.1 dBi
Fixed
0dB
A09-M8TM
Mag Mount
RPTNC
8.1 dBi
Fixed
0dB
© 2011 Digi International, Inc.
40
XBee‐PRO® XSC OEM RF Modules
Yagi antennas
A09-Y6
2 Element Yagi
RPN
6.1 dBi
Fixed / Mobile
0dB
A09-Y7
3 Element Yagi
RPN
7.1 dBi
Fixed / Mobile
0dB
A09-Y8
4 Element Yagi
RPN
8.1 dBi
Fixed / Mobile
0dB
A09-Y9
4 Element Yagi
RPN
9.1 dBi
Fixed / Mobile
0dB
A09-Y10
5 Element Yagi
RPN
10.1 dBi
Fixed / Mobile
0dB
A09-Y11
6 Element Yagi
RPN
11.1 dBi
Fixed / Mobile
0dB
A09-Y12
7 Element Yagi
RPN
12.1 dBi
Fixed / Mobile
0dB
A09-Y13
9 Element Yagi
RPN
13.1 dBi
Fixed / Mobile
0.8dB
A09-Y14
10 Element Yagi
RPN
14.1 dBi
Fixed / Mobile
1.8dB
A09-Y14
12 Element Yagi
RPN
14.1 dBi
Fixed / Mobile
1.8dB
A09-Y15
13 Element Yagi
RPN
15.1 dBi
Fixed / Mobile
2.8dB
A09-Y15
15 Element Yagi
RPN
15.1 dBi
Fixed / Mobile
2.8dB
A09-Y6TM
2 Element Yagi
RPTNC
6.1 dBi
Fixed / Mobile
0dB
A09-Y7TM
3 Element Yagi
RPTNC
7.1 dBi
Fixed / Mobile
0dB
A09-Y8TM
4 Element Yagi
RPTNC
8.1 dBi
Fixed / Mobile
0dB
A09-Y9TM
4 Element Yagi
RPTNC
9.1 dBi
Fixed / Mobile
0dB
A09-Y10TM
5 Element Yagi
RPTNC
10.1 dBi
Fixed / Mobile
0dB
A09-Y11TM
6 Element Yagi
RPTNC
11.1 dBi
Fixed / Mobile
0dB
A09-Y12TM
7 Element Yagi
RPTNC
12.1 dBi
Fixed / Mobile
0dB
A09-Y13TM
9 Element Yagi
RPTNC
13.1 dBi
Fixed / Mobile
0.8dB
A09-Y14TM
10 Element Yagi
RPTNC
14.1 dBi
Fixed / Mobile
1.8dB
A09-Y14TM
12 Element Yagi
RPTNC
14.1 dBi
Fixed / Mobile
1.8dB
A09-Y15TM
13 Element Yagi
RPTNC
15.1 dBi
Fixed / Mobile
2.8dB
A09-Y15TM
15 Element Yagi
RPTNC
15.1 dBi
Fixed / Mobile
2.8dB
© 2011 Digi International, Inc.
41
XBee‐PRO® XSC OEM RF Modules
Appendix B: Additional Information
1-Year Warranty
WARRANTY PERIOD: Digi warranties hardware Product for a period of one (1) year.
WARRANTY PROCEDURE: Upon return of the hardware Product Digi will, at its option, repair or
replace Product at no additional charge, freight prepaid, except as set forth below. Repair parts
and replacement Product will be furnished on an exchange basis and will be either reconditioned or
new. All replaced Product and parts become the property of Digi. If Digi determines that the
Product is not under warranty, it will, at the Customers option, repair the Product using current
Digi standard rates for parts and labor, and return the Product UPS Ground at no charge in or out
of warranty.
Contact Digi
Technical Support:
Phone.
(801) 765-9885
Live Chat.
www.digi.com
Online Support.
http://www.digi.com/support/eservice/login.jsp
© 2011 Digi International, Inc.
42

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : sfatunbi
Create Date                     : 2011:11:03 11:22:03-05:00
Modify Date                     : 2011:11:03 11:22:22-05:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Title                           : manual_xs_oem_rf-module_v42b5.book
Creator                         : sfatunbi
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2011:11:03 11:22:22-05:00
Producer                        : Acrobat Distiller 10.0.0 (Windows)
Document ID                     : uuid:8486715d-136d-4bc1-af83-cebb5fb59b8f
Instance ID                     : uuid:12a8ece6-25ed-4d9b-8995-692047f51b0e
Page Count                      : 42
EXIF Metadata provided by EXIF.tools
FCC ID Filing: MCQ-XBPS3B

Navigation menu