Digital Monitoring PC0156 Personal Emergency Response Base Unit User Manual Installation Guide

Digital Monitoring Products Inc Personal Emergency Response Base Unit Installation Guide

Contents

Installation Guide

InstallatIon GuIdeEM20 PERSONAL EMERGENCYRESPONSE SYStEM CONSOLECANCELTESTTROUBLECOMMPOWER TROUBLECOMMPOWER
MODEL EM20INSTALLATION GUIDE  FCC NOTICEThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.Changesormodicationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser’s authority to operate the equipment.This device has been designed to operate with the integrated 1100 Series PCB antenna having a maximum gain of 1.8 dB. Antennas having a gain greater than 1.8 dB are strictly prohibited for use with this device. The required antenna impedance is 50 ohms.If necessary, the installer should consult the dealer or an experienced radio/television technician foradditionalsuggestions.Theinstallermayndthefollowingbooklet,preparedbytheFederalCommunications Commission, helpful:“How to identify and Resolve Radio-TV Interference Problems.” ThisbookletisavailablefromtheU.S.GovernmentPrintingOfce,WashingtonD.C.20402StockNo.004-000-00345-4Industry Canada InformationThisdevicecomplieswithIndustryCanadaLicence-exemptRSSstandard(s).Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynotcauseinterference,and(2)thisdevicemustacceptanyinterference, including interference that may cause undesired operation of the device.LeprésentappareilestconformeauxCNRd’IndustrieCanadaapplicablesauxappareilsradioexemptsdelicence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage,et(2)l’utilisateurdel’appareildoitacceptertoutbrouillageradioélectriquesubi,mêmesilebrouillage est susceptible d’en compromettre le fonctionnement.©2015DigitalMonitoringProducts,Inc.InformationfurnishedbyDMPisbelievedtobeaccurateandreliable.Thisinformationissubjecttochangewithoutnotice.Caution NotesThroughoutthisguideyouwillseecautionnotescontaininginformationyouneedtoknowwheninstallingtheEM20.Thesecautionsareindicatedwithayieldsign.Wheneveryouseeacautionnote,makesureyoucompletely read and understand its information. Failing to follow the caution note can cause damage to the equipment or improper operation of one or more components in the system.
Table of ConTenTs Digital Monitoring ProductsiiiSpecications1.1  Power Supply ..................................................................................................... 11.2 Communication ................................................................................................... 11.3 EnclosureSpecications ...................................................................................... 1Introduction2.1 SystemCongurations ......................................................................................... 1System Components3.1 WiringDiagram ................................................................................................... 13.2 AccessoryDevices ............................................................................................... 1Installation4.1  Location Information ........................................................................................... 2Primary Power Supply5.1  AC Power Supply ................................................................................................ 2Secondary Power Supply6.1  Standby Battery .................................................................................................. 26.2 BatterySupervision ............................................................................................. 2Status Light Operation7.1 StatusLights ...................................................................................................... 3Programming Connection8.1 ProgrammingConnection .................................................................................... 38.2 LowPowerShutdown .......................................................................................... 3On-Board 1100 Series Wireless9.1  Wireless Antenna ................................................................................................ 3Telephone Connections10.1 Telephone .......................................................................................................... 410.2 Cellular .............................................................................................................. 410.3 FCCRegistration ................................................................................................. 410.4 Notication ......................................................................................................... 410.5 CS-03RegistrationInformation ............................................................................ 4EM20 Personal Emergency Response System Console ComplianceHomeHealthCareSignalingEquipment .............................................................................. 5ANSI/UL 1637/1635 ........................................................................................................... 511.1 HomeHealthCareSignalingEquipment ................................................................ 5
InstallatIon Digital Monitoring Products1Specications1.1  Power SupplyInput:    16.5VACStandbyBattery: 12VSealedLeadAcid1.2 CommunicationEM20C Cellular CommunicatorTheCellularcommunicatorusesDMPModel264CCDMAtocommunicatewiththeCentralStationreceiver.EM20D Dialer CommunicatorTheDialercommunicatorusesdigitaldialerlinetocommunicatewiththeCentralStationreceiver.1.3 EnclosureSpecicationsTheEM20shipsinaplasticenclosurewithaQuickStartGuide(LT-1329)andUserGuide(LT-1347).Size Color6.5”Wx6.5”Hx2.95”D WhiteIntroduction2.1 SystemCongurationsTheEM20canbeprogrammedwith16wirelesszones.System Components3.1  Wiring DiagramThe system wiring diagram in Figure 1 shows some of the accessory devices for use in various applications. A description of each module follows.3.2  Accessory Devices• 1141WallButton• 1148PersonalPendantwithLanyardandWristbandTELEPHONEWall JackELECTRICALWall JackEM20DConsoleHome Phone1148 Personal Pendant or Wristband16.5V ACPowerAdapter16 VDCEM20DELECTRICALWall JackEM20CConsole1148 Personal Pendant or Wristband16.5V ACPowerAdapter16 VDCEM20CFigure 1: Wiring Diagrams for Cellular and Dialer
InstallatIonDigital Monitoring Products 2Installation4.1  Location InformationA location should be selected that is centrally located between the 1100 Series transmitters used in the installation.PlacetheEM20awayfrommetalobjects.PlacingtheEM20onornearmetalsurfacesimpairsperformance. Primary Power Supply5.1  AC Power Supply1.  Unpackthe16.5VACpowersupplyandfullyunrollthecord.2. ConnectthepowersupplytotheRedRJ22connectiononthebackoftheEM20.3. Connect the power supply to a 120VAC outlet not controlled by a switch andsecure with the screw provided.Secondary Power Supply6.1  Standby BatteryInstall the BatteryObserve polarity when connecting battery. Ensure the battery harness connectors are fully inserted to prevent shorting.1.  TurntheEM20overandremovebatterycover.2.  The new battery comes with the harness pre-installed.3. Connect the new battery harness to the locking 4-pin headerbattery connector inside the battery compartment. Because the headeriskeyed,itcanonlybeinstalledinonedirection.4. Re-installthebatterycoverandturntheEM20upright.6.2  Battery SupervisionTheEM20teststhebatteryonceeveryhourwhenACpowerispresent.Thistestoccurs15minutespasteachhourandlastsforveseconds.A load is placed on the battery and if the battery voltage falls below 11.9V, a low battery is detected.IfDCpowerhasfailed,alowbatteryisdetectedanytimethebatteryvoltagefallsbelow11.9V.Figure 3: Step 2 & 3. Figure 2: Step 1.Figure 4: Step 4.
INStALLAtION Digital Monitoring Products3Status Light Operation7.1  Status LightsEach StatusLightindicatesthecurrentstatusoftheEM20Console.Green POWER LightOff............ NoACPower.Checkpowercordispluggedin.Blinking ......  AC Power Adapter is plugged in but the battery is low. OnSteady ..  AC Power and battery good. This is normal.Red COMM LightOff............ NormalBlinking ...... Notelephonelineorcellularconnectiondetected.OnSteady ..  Connected to an operator or sending a message.Yellow TROUBLE LightOff............ NormalBlinking ...... PressandreleasetheCANCELButtontoresetactivityonconsole.OnSteady ..  System troubles such as low battery on pendant or missing pendant.Programming Connection8.1  Programming ConnectionAlocking4-pinheaderisprovidedtoconnecttheRemoteLinkcomputerwhenusingaDMPModel399ProgrammingCabletoprogramtheunit.Afterprogrammingiscomplete,removetheModel399ProgrammingCable.Note:TousetheprogrammingheaderwiththeDMPModel399ProgrammingCable,youmustremovethebatteryconnector.Thesame4-pinheaderisusedforprogrammingandforchargingthebattery.8.2  Low Power ShutdownUsingRemoteLinkProgrammingSoftware,LowPowerShutdowncanbeenabledtopreservethebatteryduring shipment to the end user by shutting down the processor until AC Power is restored to the unit and Voice Prompt Setup is completed.  On-Board 1100 Series Wireless9.1  Wireless AntennaTheEM20WirelessAntennaisintegratedintothecircuitboard.Thebuilt-inwirelessreceiveroperateswiththeDMP1141and1148transmitters.SeesectionSystemComponents/AccessoryDevicesforalistofaccessory devices.TROUBLECOMMPOWERCANCELTESTHELPFigure 5: Status Lights
Digital Monitoring Products EM20 PERS Installation Guide4InstallatIonTelephone Connections10.1 TelephoneConnect the House Phone1.  Unpackthecolor-codedphonewireandfullyunroll.2. ConnecttheGreenwiretotheGreenRJ11ConnectoronthebackofEM20.3. ConnecttheoppositeendoftheGreenwiretothehousephonewallconnection.10.2 CellularConnect to Cellular Network1.WhenACpowerisapplied,theEM20Cwillbeginsearchingforcellularsignal.10.3  FCC RegistrationThe panel complies with FCC part 68 and is registered with the FCC.Registrationnumber:CCKAL01BXEM20Ringer Equivalence: 0.1 B10.4 NoticationRegistered terminal equipment must not be repaired by the user. In case of trouble, the device must be immediatelyunpluggedfromthetelephonejack.Thefactorywarrantyprovidesforrepairs.Registeredterminalequipmentmaynotbeusedonpartylinesorinconnectionwithcointelephones.Noticationmustbe given to the telephone company with the following information:a. The particular line(s) the service is connected tob. The FCC registration numberc. The ringer equivalenced.Themake,model,andserialnumberofthedevice10.5  CS-03 Registration InformationThisproductmeetstheapplicableIndustryCanadatechnicalspecications.Leprésentmatérielestconformeauxspecicationstechniquesapplicablesd’IndustrieCanada.TheRingerEquivalenceNumber(REN)isanindicationofthemaximumnumberofdevicesallowedtobeconnected to a telephone interface. The termination of an interface may consist of any combination of devicessubjectonlytotherequirementthatthesumoftheRENsofallthedevicesnotexceedve.L’indiced’équivalencedelasonnerie(IES)sertàindiquerlenombremaximaldeterminauxquipeuventêtreraccordés à une interface téléphonique. La terminaison d’une interface peut consister en une combinaison quelconque de dispositifs, à la seule condition que la somme d’indices d’équivalence de la sonnerie de tous les dispositifs n’excède pas cinq.TELEPHONEWall JackELECTRICALWall JackEM20DConsoleHome Phone16.5VacPowerAdapter16 VDCFigure 6: Telephone Connections. ELECTRICALWall JackEM20CConsole16.5V ACPowerAdapter16 VDCFigure 7: Cellular Connections.
800-641-4282      www.dmp.com 2500 North Partnership Boulevard  LT-1346 © 2015 Digital Monitoring Products, Inc.15415PatentsU.S.PatentNo.7,239,236CerticationsFCCPart15RegistrationIDCCKPC0156PendingIndustryCanadaID:5251A-PC0156SpecicationsBattery LifeExpectancy 2years(normaloperation) Type  12VLeadAcid FrequencyRange: 905-924MHzDimensions BaseUnitCase 6.5”Lx6.5”Wx2.95”H Color  WhiteOrdering InformationEM20DDialerCommunicatorEM20CCellularCommunicatorAccessories1141WallButton1148PersonalPendantwithLanyardandWristbandEM20 Personal Emergency Response System Console ComplianceHome Health Care Signaling EquipmentANSI/UL 1637/163511.1  Home Health Care Signaling Equipment1.  Powerfailhoursneedstobesetto8hoursorlessinSystemOptions.2. Addthecharacter“D”tothebeginningofaphonenumberinCommunicationsfortheEM20towait for a dial tone before dialing.COMPLIANCE

Navigation menu