400 and 200 Mb/s LVDS Digital
Waveform Generator/Analyzers
NEW

NI PXI-6562, NI PXI-6561
• 400 Mb/s (PXI-6562) or 200 Mb/s
(PXI-6561) maximum data rate in
double data rate (DDR) mode
• 200 MHz (PXI-6562) or 100 MHz
(PXI-6561) maximum clock rate
• LVDS signaling for fast clock rates
and low power consumption
• 16 channels with per-channel
direction control (single data
rate mode)
• 2, 16, or 128 Mb/channel
onboard memory
• Interactive waveform and script
editor software
• Synchronization and Memory Core
(SMC) for tight synchronization
with other SMC-based devices

Operating Systems
• Windows 2000/NT/XP

Recommended Software
• LabVIEW
• LabWindows/CVI

Driver and Editing
Software (included)
• NI-HSDIO driver
• Express VIs for
LabVIEW 7.1 and later
• Script Editor
• Digital Waveform Editor (included
with 16 and 128 Mb/channel models)

Description
The National Instruments PXI-6562 and PXI-6561 are 400 and 200 Mb/s
digital waveform generator/analyzers, respectively, for interfacing to
LVDS digital electronics. These modules feature 200 and 100 MHz clock
rates, respectively, single and double data rate modes, 16 channels with
per-channel direction control (in single data rate mode) and deep
onboard memory with triggering and pattern sequencing. You can also
use the modules with the NI Digital Waveform Editor, an interactive
software tool for creating and editing digital waveforms. With the SMC,
you can create mixed-signal test systems with digitizers, arbitrary
waveform generators, and other digital waveform generator/analyzers, or
you can synchronize multiple digital devices to build low-skew
multichannel systems for interfacing to high-pin-count digital ICs
and electronics.

Create and Edit Patterns Interactively
with the Digital Waveform Editor
• Import existing waveforms into LabVIEW from VHDL simulation
and spreadsheet tools in Value Change Dump (.VCD) or ASCII formats
• Create new waveforms using built-in fill patterns
• Edit waveforms interactively in the user interface

Ordering Information
NI PXI-6561 ..............................................................778993-0M1
NI PXI-6562 ..............................................................778994-0M1
1Where

M is: 1 (2 Mb/channel), 2 (16 Mb/channel), or 3 (128 Mb/channel)
Includes NI-HSDIO driver and Script Editor. The 16 and 128 Mb/channel models
also include the Digital Waveform Editor.

Software

Design High-Density Interfaces

Applications
Aerospace/Defense
Avionic subsystem communications
Surveillance systems
Satellite testing
Semiconductor
Analog-to-digital converters
Digital-to-analog converters

• 400 Mb/s (NI 6562) or 200 Mb/s
(NI 6561) maximum data rate in
double data rate (DDR) mode
• 200 MHz (NI 6562) or 100 MHz
(NI 6561) maximum clock rate
• Data delay for clock frequencies ≥ 25 MHz
• Data delay resolution as small as 60 ps
(see specifications on following page for valid delay ranges)
• Internal or external clock sources
• Tight channel-channel skew of ±215 ps (generation) or ±330 ps
(acquisition) (typical for clock frequencies at or above 25 MHz)
• 16 channels with per-channel direction control in single data rate
(SDR) mode

NI Digital Waveform Editor ........................................778724-03
Cable

SHB12X-B12X LVDS cable ..........................................192344-01
Accessories

SMA-2164 prototyping board ......................................779323-01
Mating connector for custom load boards ..................779157-01

BUY NOW!
For complete product specifications, pricing, and accessory
information, call (800) 813-3693 (U.S. only) or go to
ni.com/modularinstruments.

400 and 200 Mb/s LVDS Digital
Waveform Generator/Analyzers
Specifications
Acquisition Signal Characteristics (Data, Strobe, and PFI <0:3> Channels)

For detailed specifications, please visit ni.com/info and enter pxi6561 or pxi6562.
These specifications are valid for PXI for the temperature range 0 to 55 °C.

Channel Characteristics
Data channels .................................................. 16
Specification
Direction control
of data channels

Single Data Rate (SDR)
Data <0..15>
Per channel

Double Data Rate (DDR)
Comments
Data <0:7>
Dedicated for Using SDR, data
data generation is clocked using
Data <8:15>
Dedicated for
the rising or
data acqusition falling edge of the
Sample clock.
Using DDR, data
is clocked using
both edges of the
Sample clock.

Data channel-to-channel skew ........................ ±600 ps for sample clock rates < 25
±330 ps for sample clock rates >25 MHz
(typical across all data channels and PFI<1:2>)
Acquisition data delay range ........................... See Exported Sample Clock Delay Range table
Acquisition data delay resolution .................... 1/256 of sample clock period for clock frequencies ≥ 25 MHz
or 60 ps, whichever is greater

Waveform Characteristics
Triggers (Inputs to the NI 656x)

Output impedance (LVDS channels)................. 100 Ω differential
Channel power-up state................................... Drivers disabled, 100 Ω differential impedance

Trigger types..................................................... Start trigger, pause trigger, script trigger <0:3>
(generation sessions only), reference trigger
(acquisition sessions only), advance trigger
(acquisition sessions only)
Sources ............................................................ 1. PFI <0> (SMB jack connectors)
2. PFI <1:3> (DDC connector)
3. PXI_TRIG<0:7> (PXI backplane, PXI only)
4. PXI STAR (PXI backplane, PXI only)
5. Pattern match (acquisition sessions only)
6. Software (user function call)
7. Disabled (do not wait for a trigger)
Trigger detection .............................................. 1. Start trigger (edge detection: rising or falling)
2. Pause trigger (level detection: high or low)
3. Script trigger <0:3> (edge detection: rising or falling,
Level detection: high or low)
4. Reference triggers (edge detection: rising or falling)
5. Advance trigger (edge detection: rising or falling)
Minimum required trigger pulse width............ 30 ns
Destinations ..................................................... 1. PFI <0> (SMB jack connector)
2. PFI <1:3> (DDC connector)
3. PXI_TRIG <0:6> (PXI backplane)
Each of the triggers can be routed to any of the
destinations with the exception of pause trigger.
Pause trigger can not be exported.

Acquisition Signal Characteristics (Data, Strobe, and PFI <0:3> Channels)

Events (Outputs from the NI 656x)

Generation Signal Characteristics (data, and PFI <0:3> channels)
Generation Signal Type
Generation
voltage families
Generation
Voltage Levels
Generation
voltage levels

Typical
1.2 V

Acquisition
Voltage Families (V)
Acquisition voltage families

Acquisition
Voltage Levels
Acquisition voltage
levels (LVDS)

Data<0:15>, PFI<1:2>
LVDS

Offset (Vos)
Min
Max
1.125 V 1.375 V

PFI 0
LVCMOS

Differential Voltage (Vod)
Min
Max
Typical
247 mV 454 mV 305 mV

Data<0:15>, PFI<1:2>
and Strobe
LVDS

Voltage Threshold
Max
±50 mV

PFI 3
LVCMOS or LVDS
(software selectable)

PFI 0
LVCMOS

Comments
Into 100 Ω
differential load,
TIA/EIA-644
compliant

PFI 3
LVCMOS or LVDS
(software selectable)

Voltage Range
Min
0V

Max
2.4 V

Comments
TIA/EIA-644
compliant

Input impedance............................................... 100 Ω differential

Timing Characteristics
Sample Clock
Sample clock sources....................................... 1. Onboard clock (internal VCXO with divider)
2. CLK IN (SMB)
3. PXI_STAR (PXI only)
4. STROBE (DDC connector) – acquisition only
On board clock frequency range ..................... NI 6561: 48 Hz to 100 MHz.
(Settable to 200 MHz / N; 2 ≤ N ≤ 4,194,304)
NI 6562: 48 Hz to 200 MHz.
(Settable to 200 MHz / N; 1 ≤ N ≤ 4,194,304)
Exported Sample Clock Delay Range
Sample Clock Frequency (ƒ)
50 MHz < ƒ < maximum clock rate
25 MHz < ƒ < 50 MHz

Delay Range (Sample Clock Period)
0 to 1 sample clock period
0 to 1 sample clock period except
[0.25 ± (0.25 - 5 ns x ƒ)] and [0.75 ± (0.25 - 5 ns x ƒ)]

Exported sample clock delay resolution .......... 1/256 of sample clock period for clock frequencies ≥ 25 MHz
or 60 ps, whichever is greater

Exported Sample Clock Jitter (Typical Using Onboard Clock)
Period jitter
19 ps (rms)

Cycle-to-cycle jitter
29 ps (rms)

Generation Signal Characteristics (Data, DDC Clk Out LVDS, DDC Clk Out PECL,
and PFI <0:3> Channels)
Data channel-to-channel skew ........................
Maximum data channel toggle rate ................
Data position modes ........................................
Generation data delay range ...........................
Generation data delay resolution ....................

±215 (typical across all data channels and PFI <1:2>)
NI 6561: 100 MHz; NI 6562: 200 MHz
Rising edge, falling edge, delayed relative to sample clock
See Exported Sample Clock Delay Range table
1/256 of sample clock period for clock frequencies ≥ 25 MHz
or 60 ps, whichever is greater

Event types ....................................................... Marker <0..3>, data active event, ready for start event,
ready for advance event, End of Record Event
Destinations ..................................................... 1. PFI <0> (SMB jack connectors)
2. PFI <1:3> (DDC connector)
3. PXI_TRIG <0:6> (PXI backplane)
Each of the events can be routed to any of the destinations
with the exception of data active event. Data active event
can only be routed to the PFI channels.

Miscellaneous
Onboard Clock Characteristics (Only Valid When PLL Reference Source is Set to None)
Frequency accuracy .......................................... ±100 ppm (typical)
Temperature stability ....................................... ±30 ppm (typical)
Aging ................................................................ ±5 ppm first year (typical)

Power Requirements
Maximum.......................................................... 16.4 W

Physical
I/O Panel Connectors
Label
CLK IN
PFI 0
CLK OUT
Digital data and
control (DDC)

External Function(s)
External sample clock, External PLL
reference input
Events, triggers
Exported sample clock,
exported reference clock
Digital data channels, exported
sample clock, STROBE, events, triggers

Connector Type
SMB jack
SMB jack
SMB jack
12X InfiniBand

PXI ............................................................ Single 3U CompactPCI slot. PXI Compatible

Environment
Operating temperature..................................... PXI: 0 to 55 °C in all NI PXI chassis except the following:
0 to 45 °C when installed in an NI PXI-1000/B and
PXI-101x chassis. (Meets IEC-60068-2-1 and IEC-60068-2-2)
Storage temperature ........................................ -20 to 70 °C
Relative humidity ............................................. 10 to 90%, noncondensing (meets IEC-60068-2-56)
Storage relative humidity................................. 5 to 95%, noncondensing (meets IEC-60068-2-56)

Compliance
Safety
NI 656x devices meet the requirements of the following standards for safety and electrical equipment for
measurement, control, and laboratory use:
IEC 61010-1, EN 61010-1
UL 3111-1, UL 61010B-1
CAN/CSA C22.2 No. 1010.1
Note: For full EMC compliance, you must operate this device with shielded cabling. In addition, all covers and
filler panels must be installed. See the Declaration of Conformity (DoC) for this product for any additional
regulatory compliance information. To obtain the DoC for this product, visit ni.com/hardref.nsf.

National Instruments • info@ni.com • ni.com

2

NI Services and Support
NI has the services and support to meet
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.

Local Sales and Technical Support

SERVICE
NEEDS

In offices worldwide, our staff is local to the country, giving you
access to engineers who speak your language. NI delivers industryleading technical support through online knowledge bases, our
applications engineers, and access to 14,000 measurement and
automation professionals within NI Developer Exchange forums.
Find immediate answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of
technical support. Visit ni.com/ssp.

Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save
development time, and reduce maintenance costs over the
application life cycle. We schedule instructor-led courses in cities
worldwide, or we can hold a course at your facility. We also offer a
professional certification program that identifies individuals who
have high levels of skill and knowledge on using NI products.
Visit ni.com/training.

Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and
configure the system to your specifications. NI extends the standard
warranty by one year on hardware components (controllers, chassis,
modules) purchased with FIS. To use FIS, simply configure your
system online with ni.com/pxiadvisor.

Professional Services

OEM Support
We offer design-in consulting and product integration assistance if
you want to use our products for OEM applications. For information
about special pricing and services for OEM customers, visit
ni.com/oem.

Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.

Repair and Extended Warranty
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.

ni.com
National Instruments • info@ni.com
© 2005 National Instruments Corporation. All rights reserved. CVI, LabVIEW, National Instruments Alliance Partner, ni.com, and SCXI are
trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies.

2004_4548_101_D

Our Professional Services
Team is comprised of NI
applications engineers, NI
Consulting Services, and
a worldwide NI Alliance
Partner Program of more than 600 independent consultants and
integrators. Services range from start-up assistance to turnkey system
integration. Visit ni.com/alliance.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 3
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments
Create Date                     : 2005:02:01 12:07:49
Producer                        : QuarkXPress(tm) 6.11
Creator                         : QuarkXPress(tm) 6.11
Title                           : 04_3749_NI654.qxd
EXIF Metadata provided by EXIF.tools

Navigation menu