UL Listed Natural Gas Boosters Low Capacity Series T E C H N I C A L D A T A S H E E T Product Features Hermetically Sealed – UL Listed Single stage centrifugal design Volume to 12,000 ICFH ∆P to 9" WC Explosion-proof motor – UL Listed Performance Data GAS @ .6 Sp.Gr Catalog Number Inlet Outlet Motor Hp GL-0231-1/2-R 3 Thd GL-0244- /2-R GL-0325-1/2-R 1 º The Spencer Turbine Company introduced the first hermetically sealed multistage natural gas boosters in 1975. The company continues to lead the industry with a range of designs using Spencer's standard overhung blowers and multiple, spark-resistant aluminum alloy impellers mounted directly on heavy-duty extended motor shafts. Volume ICFH Pressure IN WC 1/2 9000 6.4 4 Thd 1/2 12000 6.75 3 Thd 1/2 5400 9 Notes: Ratings based on inlet gas at standard pressure of 14.7 PSIA, temperature 70°F, 0.6 specific gravity natural gas and 1.0 specific gravity air for UL Listing. Allowable maximum inlet to UL standards is 15.2 PSIA or 13” WC and nominal 70°F. Gas Boosters include standard shaft, 115/230V, 1Ph or 208/230/460V, 3Ph, 60Hz, 3500 RPM, class 1, group D, UL Listed, explosion-proof motor with thermal overload protection and junction box. Spencer’s Low Capacity Series UL Listed Natural Gas Booster is a single-stage design. Installations can boost pressure levels by 9 inches WC, with volumes to 12,000 ICFH. Spencer’s simple direct drive and generous internal clearances provide for long-term reliability and quiet operation — well within OSHA limits. The unique leaktight hermetic design also provides a continuous flow of natural gas around the explosion-proof motor, cooling the motor and extending its life. In addition, Spencer offers the GasCube™ series, an easy-to-install natural gas booster skid package. It is pre-engineered, prepiped and has a compact footprint. The GasCube package is also available in organized modules for on-site assembly. Spencer’s complete line of hermetic, single and multistage, low and high-pressure gas boosters — including the GasCube skid package — undergo standard commercial tests at the factory for leaks as well as for power input, volume and pressure. For information on Spencer’s High Capacity Series UL Listed Natural Gas Boosters, refer to Bulletin TDS-512 and for information on the GasCube Series, refer to Bulletin No. 515. The Spencer Turbine Company ◆ 600 Day Hill Road, Windsor, CT USA 06095 ◆ TEL 800-232-4321 ◆ 860-688-8361 ◆ www.spencerturbine.com UL Listed Natural Gas Boosters Dimensions: Low Capacity Series Gas Booster Casing Head Gasket Outlet (Position 1) Shown in inches C Impeller B Lifting Lug Rotation Inspection Port Axial Inlet Electrical Connector 231/4 113/4 ExplosionProof Motor 15/8* 141/4 16 221/8 16 /16 189/16 5 Cork Isolation Pads 1" (25 mm) thick A *1 /4 on GL-0244-1/2 -R 3 Outlet Position: Available outlet position as viewed from the outlet end of the machine. Specify position on order. Catalog Number A B C GL-O231-1/2-R 19 15/16 4 5/8 8 1/16 GL-O244-1/2-R 20 1/16 4 3/4 7 9/16 GL-O325-1/2-R 19 15/16 4 5/8 8 1/16 For Customer Approval Certified Correct Date: ________________________________________ Signed:_______________________________________ º Notes: 1. No special equipment foundation is necessary, but a level concrete floor or block is recommended. Simply rest machine on cork pads furnished; do not use anchor bolts. Flexible piping connections are recommended. 2. Outlet position must be specified when the gas booster is ordered. 3. All dimensions are for reference only unless certified. 4. All units have thermal overload protection in motor and must be connected according to NEC and local codes. Customer Name: _______________________________ Customer Order No.: ____________________________ Project Name: _________________________________ Sales Order No.:________________________________ Spencer may make improvements and dimensional changes to equipment designs based on market trends and requirements. For product selection assistance, please email marketing@spencer-air.com or visit our website at www.spencerturbine.com to locate the Spencer representative in your area. Blowers & Vacuum Systems with an Engineering Edge The Turbine Company, 600 Day Hill Road, Windsor, CT 06095-4706 TEL 800-232-4321 ◆ 860-688-8361 ◆ FAX 860-688-0098 ◆ www.spencerturbine.com TDS-513B Copyright ©2009 The Spencer Turbine Company 0809KBA1.75
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : 3.1-701 Create Date : 2009:08:13 10:33:32Z Creator Tool : QuarkXPress(R) 7.31 Modify Date : 2009:08:19 09:57:06-04:00 Metadata Date : 2009:08:19 09:57:06-04:00 Producer : QuarkXPress(R) 7.31 X Press Private : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments Format : application/pdf Title : Layout 1 Document ID : uuid:36cd81ed-ddf8-b845-bb30-a657ffe6ea53 Instance ID : uuid:b66e1258-1f36-4802-9d7f-a6b3971ea3ec Has XFA : No Page Count : 2 Creator : QuarkXPress(R) 7.31EXIF Metadata provided by EXIF.tools