Rev 0606 C M S Chip Measurement System Direct-reading Spot Measurement System ➤ No calibration gas required ➤ Fast Response — results in 20 seconds • Calibration information is stored on each CMS chip • No warm-up required • TWA and action levels reported within 1 to 2 minutes ➤ System integrity assured • Electronic system self-test performed upon start-up • Sampling system test performed before each test ➤ Highly accurate • Accuracy ± 4 to 7% of measured value for most gases • Consistent flow maintained and corrected for changes in atmospheric pressure • Measure quantities as low as 0.20 ppm benzene • Not subject to human error and bias ➤ No battery charging • Operates on AA size alkaline batteries • Ready for instant use — ideal for emergency response ➤ Internal data recorder ➤ Simple 1, 2, 3 operation • Stores up to 50 measurements • Data includes time/date, containment/concentration, and sequential number of measurement series • User may enter measurement location • Recall and display data on demand • Minimal training required ➤ Concentration displayed on easy-to-read backlit digital readout in any one of four languages Dräger CMS combines substance-specific measuring chips with an electronic-based analyzer for an easy-to-use spot measurement system that responds quickly and accurately to your sampling needs. CMS Easy Operation 1 2 Turn on unit by moving the slide to position 1. Wait for “load chip” prompt. 3 Follow instructions on display to load chip. Move slide to position 2. Wait for “chip ok.” Move slide to position 3 to perform measurement. The CMS Analyzer The CMS Analyzer is comprised of: 1. A revolutionary optical system that analyzes color. 2. An integral mass flow controller and pump system that provide unparalleled reproducibility. The CMS Chips Bar code Direction of insert 10 measurement Each CMS Chip contains 10 capillaries (10 tests) filled with substance-specific reagent. A barcode on the chip is read by the analyzer optics to obtain information such as gas type, measuring range, and required measuring time. Gas type, part number, and batch number are printed on the chip for user convenience. Chip calibration remains valid for two years. SKC Inc. 800-752-8472 SKC South 800-752-7684 SKC Gulf Coast 800-225-1309 SKC Inc. 800-752-8472 www.skcinc.com www.skcinc.com 1 SKC South 800-752-7684 SKC West 800-752-9378 C M S Chip Measurement System Direct-reading Spot Measurement System CMS Analyzer* CMS Chips Description Cat. No. CMS Analyzer Set with Data Recorder includes analyzer, 4 AA alkaline batteries, and Allen wrench Remote System includes pump, 3-meter extension hose, float-probe, and screwdriver Pump/Analyzer Remote System, pump permanently attached to analyzer Complete Emergency Response Kit includes analyzer, remote system, telescopic probe, 10 chips (chlorine, ammonia, petroleum hydrocarbons, perchloroethylene, hydrogen sulfide, nitrous fumes†, carbon dioxide, carbon monoxide, hydrochloric acid, and sulfur dioxide) Indoor Air Kit includes analyzer and four chips (carbon dioxide, carbon monoxide, ozone, and formaldehyde) Accessories Leather Carry Case & shoulder strap Extension Hose includes connector and float probe, to be used with analyzer/ remote pump 802-17700 only 3 meter Hose 10 meter Hose Probe Bar with 1-meter Extension Hose, to be used with analyzer/remote pump 802-17700 only * Price 802-05200 $ 1,729.00 802-05060 569.00 802-17700 2,365.00 802-55711 3,585.00 802-56455 2,035.00 802-05080 105.00 802-17614 802-17613 107.00 170.00 802-17963 173.00 Now available with deep mine approval. Contact your SKC representative for more information. Prices subject to change without notice Chip Measuring range (ppm) Cat. No. Acetic acid 2 - 50 Acetone 40 - 600 Ammonia 0.20 - 5.0 Ammonia 2 - 50 Ammonia 10 - 150 Ammonia 100 - 2,000 Benzene‡ 0.2 - 10 Benzene‡ 0.5 - 10 Butadiene 1 - 25 Carbon dioxide 200 - 3,000 Carbon dioxide 1,000 - 25,000 Carbon dioxide 1 - 20 Vol % Carbon monoxide 5 - 150 Chlorine 0.2 - 10 Ethanol 100 - 2,500 Ethylene oxide 0.4 - 5.0 Formaldehyde 0.2 - 5.0 Hydrochloric acid 1 - 25 Hydrochloric acid 20 - 500 Hydrogen cyanide 2 - 50 Hydrogen peroxide 0.2 - 2.0 Hydrogen sulfide 0.20 - 5.0 Hydrogen sulfide 2 - 50 Hydrogen sulfide 20 - 500 Hydrogen sulfide 100 - 2,500 Isopropanol 40 - 1,000 Mercaptan 0.25 - 6.0 Methanol 20 - 500 Methyl tert Butyl Ether (MTBE) 10 - 200 Methylene chloride 20 - 400 Nitrogen dioxide 0.5 - 25 Nitrous fumes† 0.5 - 15 Nitrous fumes† 10 - 200 Oxygen 1 - 25 Vol % Ozone 25 - 1,000 (ppb) Perchloroethylene 5 - 150 Petr. hydrocarbons 20 - 500 Petr. hydrocarbons 100 - 3,000 Phosgene 0.05 - 2.0 Phosphine 0.1 - 2.5 Phosphine 1 - 25 Phosphine 20 - 500 Phosphine 200 - 5,000 Propane 100 - 2,000 Styrene 2.0 - 40 Sulfur dioxide 0.4 - 10 Sulfur dioxide 5 - 150 Toluene‡ 10 - 300 Training Chip — Trichloroethylene 5 - 100 Vinyl chloride 0.3 - 10 Vinyl chloride 10 - 250 Water Vapor 0.4 - 10.0 mg/L Xylene‡ 10 - 300 802-06330 802-06470 802-06550 802-06130 802-06020 802-06570 802-06030‡ 802-06160‡ 802-06460 802-06190 802-06070 802-06210 802-06080 802-06010 802-06370 802-06580 802-06540 802-06090 802-06140 802-06100 802-06440 802-06520 802-06050 802-06150 802-06220 802-06390 802-06360 802-06380 802-06530 802-06510 802-06120 802-06060† 802-06240† 802-06490 802-06430 802-06040 802-06200 802-06270 802-06340 802-06400 802-06410 802-06420 802-06500 802-06310 802-06560 802-06110 802-06180 802-06250‡ 802-06290 802-06320 802-06170 802-06230 802-06450 802-06260‡ Price $ 82.50 82.50 82.50 57.50 57.50 63.00 162.50 162.50 82.50 57.50 55.50 57.50 55.50 57.50 82.50 149.50 82.50 74.00 74.00 69.00 86.50 82.50 57.50 57.50 57.50 99.00 99.00 99.00 82.50 82.50 57.50 55.50 57.50 102.00 82.50 69.00 86.50 82.50 99.00 73.00 73.00 73.00 74.00 82.50 82.50 57.50 69.00 73.00 22.50 69.00 73.00 73.00 84.50 69.00 Convenient CMS Kits CMS is available separately or in two application-specific kits. Indoor Air Quality Kit This kit combines the CMS analyzer with chips for the most commonly measured gases and vapors in indoor air investigations (carbon monoxide, carbon dioxide, formaldehyde, and ozone). It is an excellent tool for checking chemical contaminants for this application. See ordering at left. Emergency Response Kit With the alkaline battery-powered CMS analyzer, remote system, telescopic probe, and chips for 10 different contaminants contained in this kit, you should be ready for most emergency response situations. See ordering at left. ‡ Requires refrigerated storage below 50 F (10 C) † Detects nitric oxide (NO) and nitrogen dioxide (NO2 ) only; not suitable for nitrous oxide. For all your air sampling needs. 2 SKC Inc. 800-752-8472 SKC South 800-752-7684 SKC Gulf Coast 800-225-1309 SKC West 800-752-9378 www.skcinc.com SKC West 800-752-9378 SKC Gulf Coast 800-225-1309 www.skcinc.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Fill forms, Extract, Assemble, Print high-res Create Date : 2006:06:14 09:18:15-05:00 Modify Date : 2008:06:25 10:14:53-04:00 Subject : Chip Measurement System Spec Sheet PDF Document, CMS Specsheet Keywords : Chip, Measurement, System, Spec, Sheet, PDF, Document, CMS Page Count : 2 Creation Date : 2006:06:14 09:18:15-05:00 Mod Date : 2008:06:25 10:14:53-04:00 Producer : Acrobat Distiller 5.0.5 for Macintosh Author : SKC Inc. Metadata Date : 2008:06:25 10:14:53-04:00 Creator : SKC Inc. Title : Chip Measurement System Spec Sheet PDF Document, CMS Specsheet Description : Chip Measurement System Spec Sheet PDF Document, CMS SpecsheetEXIF Metadata provided by EXIF.tools