Digi XBee3® Cellular LTE Cat 1
Smart Modem

User Guide

Revision history—90002253
Revision Date

Description

A

January
2018

Initial release of the document.

B

February Added instructions for sending an SCI request to Remote Manager. Added
2018
details on SPI operation. Added antenna keepout area for Bluetooth. Updated
specifications for Bluetooth.

C

June
2018

0B software release. Added file system and TLS sections, AT commands and
related changes.

D

August
2018

Updated list of cipher suites. Updated Get Started section.

Trademarks and copyright
Digi, Digi International, and the Digi logo are trademarks or registered trademarks in the United
States and other countries worldwide. All other trademarks mentioned in this document are the
property of their respective owners.
© 2018 Digi International Inc. All rights reserved.

Disclaimers
Information in this document is subject to change without notice and does not represent a
commitment on the part of Digi International. Digi provides this document “as is,” without warranty of
any kind, expressed or implied, including, but not limited to, the implied warranties of fitness or
merchantability for a particular purpose. Digi may make improvements and/or changes in this manual
or in the product(s) and/or the program(s) described in this manual at any time.

Warranty
To view product warranty information, go to the following website:
www.digi.com/howtobuy/terms

Send comments
Documentation feedback: To provide feedback on this document, send your comments to
techcomm@digi.com.

Customer support
Digi Technical Support: Digi offers multiple technical support plans and service packages to help our
customers get the most out of their Digi product. For information on Technical Support plans and
pricing, contact us at +1 952.912.3444 or visit us at www.digi.com/support.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

2

Contents
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
Applicable firmware and hardware
SIM cards

11
11

Get started with the XBee Smart Modem Development Kit
Identify the kit contents
Connect the hardware
XBIB-U-DEV reference
Cellular service
Configure the device using XCTU
Add a device
Check for cellular registration and connection
Update to the latest firmware

13
14
16
17
18
18
19
19

Connection examples
Connect to the Echo server
Debugging
Connect to the ELIZA server
Debugging
Connect to the Daytime server
Debugging
Send an SMS message to a phone
Debugging
Perform a (GET) HTTP request
Debugging
Get started with CoAP
CoAP terms
CoAP quick start example
Configure the device
Example: manually perform a CoAP request
Example: use Python to generate a CoAP message
Connect to a TCP/IP address
Debugging
Get started with MQTT
Example: MQTT connect
Send a connect packet
Example: send messages (publish) with MQTT
Example: receive messages (subscribe) with MQTT

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

22
23
24
25
26
27
28
29
30
31
32
32
32
33
33
34
37
37
39
39
41
42
43

3

Use MQTT over the XBee Cellular Modem with a PC
Software libraries

44
47

Get started with MicroPython
About MicroPython
Why use MicroPython
MicroPython on the XBee Smart Modem
Use XCTU to enter the MicroPython environment
Use the MicroPython Terminal in XCTU
Troubleshooting
Example: hello world
Example: turn on an LED
Example: code a request help button
Enter MicroPython paste mode
Catch a button press
Send a text (SMS) when the button is pressed
Add the time the button was pressed
Exit MicroPython mode
Other terminal programs
Tera Term for Windows
Use picocom in Linux

48
48
48
49
49
49
50
50
51
51
52
53
54
55
55
56
57

Technical specifications
Interface and hardware specifications
RF characteristics
Networking specifications
Power requirements
Power consumption
Electrical specifications
Regulatory approvals

60
60
60
60
61
61
62

Hardware
Mechanical drawings
Pin signals
Pin connection recommendations
RSSI PWM
SIM card
The Associate LED

64
64
65
66
66
66

Antenna recommendations
Antenna connections
Keepout area
Through-hole keepout
Antenna placement

69
70
71
71

Design recommendations
Cellular component firmware updates

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

73

4

USB Direct design
Power supply considerations
Recommended application circuit
Heat considerations and testing
Heat sink guidelines
Add a fan to provide active cooling

73
73
74
74
75
76

Cellular connection process
Connecting
Cellular network
Data network connection
Data communication with remote servers (TCP/UDP)
Disconnecting
SMS encoding

78
78
78
78
78
79

Modes
Select an operating mode
Transparent operating mode
API operating mode
Bypass operating mode
Enter Bypass operating mode
Leave Bypass operating mode
Restore cellular settings to default in Bypass operating mode
USB direct mode
Enable USB direct mode
Command mode
Enter Command mode
Troubleshooting
Send AT commands
Response to AT commands
Apply command changes
Make command changes permanent
Exit Command mode
MicroPython mode

81
82
82
82
82
83
83
83
83
83
84
84
84
85
85
85
85
86

Sleep modes
About sleep modes
Normal mode
Pin sleep mode
Cyclic sleep mode
Cyclic sleep with pin wake up mode
Connected sleep mode
The sleep timer
MicroPython sleep behavior

88
88
88
88
88
88
89
89

Power saving features
Airplane mode

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

91

5

Serial communication
Serial interface
Serial data
UART data flow
Serial buffers
CTS flow control
RTS flow control
Enable UART or SPI ports

93
93
93
93
94
94
94

SPI operation
SPI communications
Full duplex operation
Low power operation
Select the SPI port
Force UART operation
Data format

96
97
98
98
99
99

File system
Overview of the file system
Directory structure
Paths
Secure files
XCTU interface
Encrypt files

101
101
101
101
102
102

Socket behavior
Supported sockets
Socket timeouts
Socket limits in API mode
Enable incoming TCP connections
API mode behavior for outgoing TCP and SSL connections
API mode behavior for outgoing UDP data
API mode behavior for incoming TCP connections
API mode behavior for incoming UDP data
Transparent mode behavior for outgoing TCP and SSL connections
Transparent mode behavior for outgoing UDP data
Transparent mode behavior for incoming TCP connections
Transparent mode behavior for incoming UDP connections

104
104
104
104
105
105
105
106
106
107
107
107

Transport Layer Security (TLS)
TLS AT commands
Transparent mode and TLS
API mode and TLS
Key formats
Certificate formats
Certificate limitations
Cipher suites

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

109
110
110
110
110
110
110

6

Server Name Indication (SNI)

111

AT commands
Special commands
AC (Apply Changes)
FR (Force Reset)
RE command
WR (Write)
Cellular commands
PH (Phone Number)
S# (ICCID)
IM (IMEI)
MN (Operator)
MV (Modem Firmware Version)
DB (Cellular Signal Strength)
AN (Access Point Name)
CP (Carrier Profile)
OA (Operating APN)
AM (Airplane Mode)
DV (Antenna Diversity)
Network commands
IP (IP Protocol)
TL (SSL/TLS Protocol Version)
$0 (SSL/TLS Profile 0)
$1 (SSL/TLS Profile 1)
$2 (SSL/TLS Profile 2)
TM (IP Client Connection Timeout)
TS (IP Server Connection Timeout)
DO (Device Options)
EQ (Remote Manager FQDN)
Addressing commands
SH (Serial Number High)
SL (Serial Number Low)
MY (Module IP Address)
P# (Destination Phone Number)
N1 (DNS Address)
N2 (DNS Address)
DL (Destination Address)
OD (Operating Destination Address)
DE (Destination Port)
C0 (Source Port)
LA (Lookup IP Address of FQDN)
Serial interfacing commands
BD (Baud Rate)
NB (Parity)
SB (Stop Bits)
RO (Packetization Timeout)
TD (Text Delimiter)
FT (Flow Control Threshold)
AP (API Enable)
I/O settings commands
D0 (DIO0/AD0)
D1 (DIO1/AD1)
D2 (DIO2/AD2)

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

113
113
113
113
113
114
114
114
114
114
115
115
115
115
116
116
116
117
117
117
118
118
118
119
119
119
120
120
120
120
120
121
121
121
121
122
122
122
122
123
123
123
124
124
124
125
125
125
125
126
126

7

D3 (DIO3/AD3)
D4 (DIO4)
D5 (DIO5/ASSOCIATED_INDICATOR)
D6 (DIO6/RTS)
D7 (DIO7/CTS)
D8 (DIO8/SLEEP_REQUEST)
P0 (DIO10/PWM0 Configuration)
P1 (DIO11/PWM1 Configuration)
P2 (DIO12 Configuration)
P3 (DIO13/DOUT)
P4 (DIO14/DIN)
PD (Pull Direction)
PR (Pull-up/down Resistor Enable)
M0 (PWM0 Duty Cycle)
I/O sampling commands
TP (Temperature)
IS (Force Sample)
Sleep commands
SM (Sleep Mode)
SP (Sleep Period)
ST (Wake Time)
SO (Sleep Options)
Command mode options
CC (Command Sequence Character)
CT (Command Mode Timeout)
CN (Exit Command mode)
GT (Guard Times)
MicroPython commands
PS (Python Startup)
PY (MicroPython Command)
Firmware version/information commands
VR (Firmware Version)
VL (Verbose Firmware Version)
HV (Hardware Version)
AI (Association Indication)
HS (Hardware Series)
CK (Configuration CRC)
Diagnostic interface commands
DI (Remote Manager Indicator)
CI (Protocol/Connection Indication)
Execution commands
NR (Network Reset)
!R (Modem Reset)
File system commands
Error responses
ATFS (File System)
ATFS PWD
ATFS CD directory
ATFS MD directory
ATFS LS [directory]
ATFS PUT filename
ATFS XPUT filename
ATFS HASH filename
ATFS GET filename
ATFS MV source_path dest_path

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

127
127
128
128
129
129
130
130
131
131
132
132
132
133
133
134
134
135
135
135
135
136
136
136
136
137
137
137
137
138
138
139
139
139
139
140
140
140
140
141
143
143
143
143
144
144
144
144
144
144
144
145
145
145
145

8

ATFS RM file_or_directory
ATFS INFO
ATFS FORMAT confirm

145
145
145

Operate in API mode
API mode overview
Use the AP command to set the operation mode
API frame format
API operation (AP parameter = 1)
API operation with escaped characters (AP parameter = 2)

147
147
147
147
148

API frames
AT Command - 0x08
Transmit (TX) SMS - 0x1F
Transmit (TX) Request: IPv4 - 0x20
Tx Request with TLS Profile - 0x23
AT Command Response - 0x88
Transmit (TX) Status - 0x89
Modem Status - 0x8A
Receive (RX) Packet: SMS - 0x9F
Receive (RX) Packet: IPv4 - 0xB0

152
153
154
156
158
159
161
162
163

Configure the XBee Smart Modem using Digi Remote Manager
Create a Remote Manager account
Get the XBee Smart Modem IMEI number
Add a XBee Smart Modem to Remote Manager
Update the firmware
Update the firmware using web services
Example: update the XBee firmware synchronously with Python 3.0
Example: use the device's firmware image to update the XBee firmware synchronously

165
165
165
166
166
166
167

Troubleshooting
Cannot find the serial port for the device
Condition
Solution
Other possible issues
Enable Virtual COM port (VCP) on the driver
Correct a macOS Java error
Condition
Solution
Unresponsive cellular component in Bypass mode
Condition
Solution
Not on expected network after APN change
Condition
Solution
Syntax error at line 1
Solution
Error Failed to send SMS

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

170
170
170
171
171
172
172
172
173
173
173
174
174
174
174
174
174

9

Solution

174

Regulatory information
Modification statement
Interference statement
FCC Class B digital device notice
RF exposure
FCC-approved antennas
Bluetooth antennas
Dipole antennas
Flex PCB antennas
Cellular antennas
Labeling requirements for the host device

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

176
176
176
177
177
177
177
177
178
178

10

Digi XBee3 Cellular LTE Cat 1 Smart Modem User
Guide
The XBee Smart Modem contains a u-blox R410M-02B module that also supports NB-IoT. Digi has not
released support for the NB-IoT feature. Contact your sales representative if you would like more
information about our roadmap to support NB-IoT.
The XBee Smart Modem is an embedded Long-Term Evolution (LTE) Category 1 cellular module that
provides original equipment manufacturers (OEMs) with a simple way to integrate cellular
connectivity into their devices.
The XBee Smart Modem enables OEMs to quickly integrate cutting edge 4G cellular technology into
their devices and applications without dealing with the painful, time-consuming, and expensive FCC
and carrier end-device certifications.
With the full suite of standard XBee API frames and AT commands, existing XBee customers can
seamlessly transition to this new device with only minor software adjustments. When OEMs add the
XBee Smart Modem to their product, they create a future-proof design with flexibility to switch
between wireless protocols or frequencies as needed.
You can read some frequently asked questions here.

Applicable firmware and hardware
This manual supports the following firmware:
n 310xx
It supports the following hardware:
n XB3-C-A1-UT-xxx

SIM cards
The XBee Smart Modem requires a 4FF (Nano) size SIM card. The SIM interface supports both 1.8 V
and 3 V SIM types.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

11

Get started with the XBee Smart Modem
Development Kit
This section describes how to connect the hardware in the XBee Smart Modem Development Kit, and
provides some examples you can use to communicate with the device.
1. Identify the kit contents
2. Connect the hardware
3. Review the development board
4. Set up cellular service
5. Configure the device using XCTU
6. Use one of the following methods to verify your cellular connection:
n

Connect to the Echo server

n

Connect to the ELIZA server

n

Connect to the Daytime server

7. Review additional connection examples to help you learn how to use the device. See
Connection examples.
8. Review introductory MicroPython examples. See Get started with MicroPython.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

12

Identify the kit contents
The Developer's kit includes the following:

One XBIB-U-DEV board

One 12 V power supply

Two cellular antennas with U.FL connectors

One USB cable

One XBee Smart Modem
Note The XBee Smart Modem comes
attached to the board in ESD wrap.
One SIM card

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

13

Get started with the XBee Smart Modem Development Kit

Connect the hardware

Connect the hardware

1. The XBee Smart Modem should already be plugged into the XBIB-U-DEV board.
2. The SIM card should be already be inserted into the XBee Smart Modem. If not, install the
SIM card into the XBee Smart Modem.
WARNING! Never insert or remove the SIM card while the device is powered!

3. Connect the antennas to the XBee Smart Modem by aligning the U.FL connectors carefully,
then firmly pressing straight down to seat the connector. You should hear a snap when the
antenna attaches correctly. U.FL is fragile and is not designed for multiple insertions, so
exercise caution when connecting or removing the antennas. We recommend using a U.FL
removal tool.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

14

Get started with the XBee Smart Modem Development Kit

Connect the hardware

4. Plug the 12 V power supply to the power jack on the development board.
5. Connect the USB cable from a PC to the USB port on the development board. The computer
searches for a driver, which can take a few minutes to install.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

15

Get started with the XBee Smart Modem Development Kit

XBIB-U-DEV reference

XBIB-U-DEV reference
This picture shows the XBee USB development board and the table that follows explains the callouts
in the picture.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

16

Get started with the XBee Smart Modem Development Kit

Number Item

Cellular service

Description

1

Programming header Header used to program XBee programmable devices.

2

Self power module

Advanced users only—voids the warranty. Depopulate R31 to
power the device using V+ and GND from J2 and J5. You can
connect sense lines to S+ and S- for sensing power supplies.
CAUTION: Voltage is not regulated. Applying the incorrect
voltage can cause fire and serious injury.1

3

Current testing

Depopulating R31 allows a current probe to be inserted across P6
terminals. The current though P6/R31 powers the device only.
Other supporting circuitry is powered by a different trace.

4

Loopback jumper

Populating P8 with a loopback jumper causes serial transmissions
both from the device and from the USB to loopback.

5

DC barrel plug: 6-20 V Greater than 500 mA loads require a DC supply for correct
operation. Plug in the external power supply prior to the USB
connector to ensure that proper USB communications are not
interrupted.

6

LED indicator

7

USB

8

RSSI indicator

See RSSI PWM. On the XBIB-U, more lights are better.

9

User buttons

Connected to DIO lines for user implementation.

10

Reset button

11

SPI power

Connect to the power board from 3.3 V.

12

SPI

Only used for surface-mount devices.

13

Indicator LEDs

DS5: ON/SLEEP
DS2: DIO12, the LED illuminates when driven low.
DS3: DIO11, the LED illuminates when driven low.
DS4: DIO4, the LED illuminates when driven low.

14

Through-hole XBee
sockets

15

20-pin header

Yellow: Modem sending serial/UART data to host.
Green: Modem receiving serial/UART data from host.
Red: Associate.

Maps to standard through-hole XBee pins.

Cellular service
Digi now offers Cellular Bundled Service plans. This service includes preconfigured cellular data
options that are ideal for IoT applications, bundled together with Digi Remote Manager for customers

1Powering the board with J2 and J5 without R31 removed can cause shorts if the USB or barrel plug power are

connected. Applying too high a voltage destroys electronic circuitry in the device and other board components
and/or can cause injury.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

17

Get started with the XBee Smart Modem Development Kit

Configure the device using XCTU

who want to remotely monitor and manage their devices. To learn more, or obtain the plan that is
right for your needs, contact us:
n By phone: 1-877-890-4014 (USA/toll free) or +1-952-912-3456 (International). Select the
Wireless Plan Support or Activation option in the menu.
n

By email: Data.Plan.QuoteDesk@digi.com.

The XBee Cellular kit includes six months of free cellular service.1

Configure the device using XCTU
XBee Configuration and Test Utility (XCTU) is a multi-platform program that enables users to interact
with Digi radio frequency (RF) devices through a graphical interface. The application includes built-in
tools that make it easy to set up, configure, and test Digi RF devices.
XCTU does not work directly over an SPI interface.
For instructions on downloading and using XCTU, see the XCTU User Guide.
To use XCTU, you may need to install FTDI Virtual COM port (VCP) drivers onto your computer. Click
here to download the drivers for your operating system.
Note If you are on a macOS computer and encounter problems installing XCTU, see Correct a macOS
Java error.

Add a device
These instructions show you how to add the XBee Smart Modem to XCTU.
If XCTU does not find your serial port, see Cannot find the serial port for the device and Enable Virtual
COM port (VCP) on the driver.
.
1. Launch XCTU
Note XCTU's Update the radio module firmware dialog box may open and will not allow you to
continue until you click Update or Cancel on the dialog.
2. Click Help > Check for XCTU Updates to ensure you are using the latest version of XCTU.
3. Click the Discover radio modules button

.

4. In the Discover radio devices dialog, select the serial ports where you want to look for XBee
modules, and click Next.
5. In the Set port parameters window, maintain the default values and click Finish.
6. As XCTU locates radio modules, they appear in the Discovering radio modules dialog box.
If your module could not be found, XCTU displays the Could not find any radio module dialog
providing possible reasons why the module could not be added.

1Six months of free cellular service assumes a rate of 5 Mb/month. If you exceed a limit of 30 Mb during the six

month period your SIM will be deactivated.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

18

Get started with the XBee Smart Modem Development Kit

Configure the device using XCTU

Check for cellular registration and connection
In the following examples, proper cellular network registration and address assignment must occur
successfully. The LED on the development board blinks when the XBee Smart Modem is registered to
the cellular network; see The Associate LED. If the LED remains solid, registration has not occurred
properly.
Registration can take several minutes.
Note Make sure you are in an area with adequate cellular network reception or the XBee Smart
Modem will not make the connection.
Note Check the antenna connections if the device has trouble connecting to the network.
In addition to the LED confirmation, you can check the AT commands below in XCTU to check the
registration and connection. To view these commands:
1. Open XCTU and Add a device.
2. Click the Configuration working mode

button.

3. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
4. Update to the latest firmware.
Note To search for an AT command in XCTU, use the search box

.

The relevant commands are:
n AI (Association Indication) reads zero when the device successfully registers to the cellular
network. If it reads 23 it is connecting to the Internet; 22 means it is registering to the cellular
network.
n

MY (Module IP Address) should display a valid IP address. If it reads 0.0.0.0, it has not
registered yet.

Note To read a command's value, click the Read button

next to the command.

Update to the latest firmware
Firmware is the program code stored in the device's persistent memory that provides the control
program for the device. Use XCTU to update the firmware.
Note If you have already updated the firmware in a previous step, this process is not necessary.
1. Click the Configuration working modes button

.

2. Select a local XBee module from the Radio Modules list.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

19

Get started with the XBee Smart Modem Development Kit

3. Click the Update firmware button

Configure the device using XCTU

to ensure you have the most current firmware.

The Update firmware dialog displays the available and compatible firmware for the selected
XBee module.
4. Make sure you check the Force the module to maintain its current configuration box and
then click Update.
5. Select the product family of the XBee module, the function set, and the latest firmware version.
6. Click Update. A dialog displays update progress. Click Show details for details of the firmware
update process.
See How to update the firmware of your modules in the XCTU User Guide for more information.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

20

Connection examples
The following examples provide some additional scenarios you can try to get familiar with the XBee
Smart Modem.
Connect to the Echo server
Connect to the ELIZA server
Connect to the Daytime server
Send an SMS message to a phone
Perform a (GET) HTTP request
Get started with CoAP
Connect to a TCP/IP address
Get started with MQTT
Software libraries

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

22
24
26
28
30
32
37
39
47

21

Connect to the Echo server
This server echoes back the messages you type.
The following table explains the AT commands that you use in this example.
At
command

Value

Description

IP (IP
Protocol)

1

Set the expected transmission mode to TCP communications.

TD (Text
Delimiter)

D (0x0D)

The text delimiter to be used for Transparent mode, as an ASCII hex
code. No information is sent until this character is entered, unless the
maximum number of characters has been reached. Set to zero to
disable text delimiter checking. Set to D for a carriage return.

DL
52.43.121.77 The target IP address of the echo server.
(Destination
Address)
DE
0x2329
(Destination
Port)

The target port number of the echo server.

To communicate with the Echo server:
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and Add a device.
3. Click the Configuration working mode

button.

4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. To switch to TCP communication, in the IP field, select 1 and click the Write button

.

6. To enable the XBee Smart Modem to recognize carriage return as a message delimiter, in the
TD field, type D and click the Write button.
7. To enter the destination address of the echo server, in the DL field, type 52.43.121.77 and click
the Write button.
8. To enter the destination IP port number, in the DE field, type 2329 and click the Write button.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

22

Connection examples

Connect to the Echo server

9. Click the Consoles working mode button

on the toolbar to open a serial console to the

device. For instructions on using the Console, see the AT console topic in the XCTU User Guide.
10. Click the Open button

to open a serial connection to the device.

11. Click in the left pane of the Console log, then type in the Console to talk to the echo server.
The following screenshot provides an example of this chat.

Debugging
If you experience problems with the settings in this example, you can load the default settings in
XCTU:
1. On the Configuration toolbar, click the Default button

to load the default values

established by the firmware, and click Yes to confirm.
2. Factory settings are loaded but not written to the device. To write them, click the Write button
on the toolbar.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

23

Connection examples

Connect to the ELIZA server

Connect to the ELIZA server
You can use the XBee Smart Modem to chat with the ELIZA Therapist Bot. ELIZA is an artificial
intelligence (AI) bot that emulates a therapist and can perform simple conversations.
The following table explains the AT commands that you use in this example.
At command

Value

Description

IP (IP Protocol)

1

Set the expected transmission mode to TCP
communications.

DL (Destination
Address)

52.43.121.77 The target IP address of the ELIZA server.

DE (Destination Port)

0x2328

The target port number of the ELIZA server.

To communicate with the ELIZA Therapist Bot:
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and Add a device.
3. Click the Configuration working mode

button.

4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. To switch to TCP communication, in the IP field, select 1 and click the Write button

.

6. To enter the destination address of the ELIZA Therapist Bot, in the DL field, type 52.43.121.77
and click the Write button.
7. To enter the destination IP port number, in the DE field, type 2328 and click the Write button.
8. Click the Consoles working mode button

on the toolbar to open a serial console to the

device. For instructions on using the Console, see the AT console topic in the XCTU User Guide.
9. Click the Open button

to open a serial connection to the device.

10. Click in the left pane of the Console log, then type in the Console to talk to the ELIZA Therapist
Bot. The following screenshot provides an example of this chat with the user's text in blue.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

24

Connection examples

Connect to the ELIZA server

Debugging
If you experience problems with the settings in this example, you can load the default settings in
XCTU:
1. On the Configuration toolbar, click the Default button

to load the default values

established by the firmware, and click Yes to confirm.
2. Factory settings are loaded but not written to the device. To write them, click the Write button
on the toolbar.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

25

Connection examples

Connect to the Daytime server

Connect to the Daytime server
The Daytime server reports the current Coordinated Universal Time (UTC) value responding to any
user input.
The following table explains the AT commands that you use in this example.
At
command
IP (IP
Protocol)

Value

Description

1

Set the expected transmission mode to TCP communications.

DL
52.43.121.77 The target IP of the Daytime server.
(Destination
Address)
DE
0x232A
(Destination
Port)

The target port number of the Daytime server.

TD (Text
Delimiter)

The text delimiter to be used for Transparent mode, as an ASCII hex
code. No information is sent until this character is entered, unless the
maximum number of characters has been reached. Set to zero to
disable text delimiter checking.

0

To communicate with the Daytime server:
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and Add a device.
3. Click the Configuration working mode

button.

4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. To switch to TCP communication, in the IP field, select 1 and click the Write button

.

6. To enter the destination address of the daytime server, in the DL field, type 52.43.121.77 and
click the Write button.
7. To enter the destination IP port number, in the DE field, type 232A and click the Write button.
8. To disable text delimiter checking, in the TD field, type 0 and click the Write button.
9. Click the Consoles working mode button

on the toolbar to open a serial console to the

device. For instructions on using the Console, see the AT console topic in the XCTU User Guide.
10. Click the Open button

to open a serial connection to the device.

11. Click in the left pane of the Console log, then type in the Console to query the Daytime server.
The following screenshot provides an example of this chat.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

26

Connection examples

Connect to the Daytime server

Debugging
If you experience problems with the settings in this example, you can load the default settings in
XCTU:
1. On the Configuration toolbar, click the Default button

to load the default values

established by the firmware, and click Yes to confirm.
2. Factory settings are loaded but not written to the device. To write them, click the Write button
on the toolbar.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

27

Connection examples

Send an SMS message to a phone

Send an SMS message to a phone
The XBee Smart Modem can send and receive Short Message Service (SMS) transmissions (text
messages) while in Transparent mode. This allows you to send and receive text messages to and from
an SMS capable device such as a mobile phone.
The following table explains the AT commands that you use in this example.
Command

Value

Description

AP (API Enable)

0

Set the device's API mode to Transparent mode.

IP (IP Protocol)

2

Set the expected transmission mode to SMS communication.

P#
 on using this command.
TD (Text Delimiter) D (0x0D)

The text delimiter to be used for Transparent mode, as an ASCII hex
code. No information is sent until this character is entered, unless
the maximum number of characters has been reached. Set to 0 to
disable text delimiter checking. Set to D for a carriage return.

PH (Module's SIM
phone number)

The value that represents your device's phone number as supplied
by the SIM card. This is used to send text messages to the device
from another cellular device.

Read
only

1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and Add a device.
3. Click the Configuration working mode

button.

4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. To switch to SMS communication, in the IP field, select 2 and click the Write button

.

6. To enter your cell phone number, in the P# field, type the  and click
the Write button. Type the phone number using only numbers, with no dashes. You can use the
+ prefix if necessary. The target phone number is the phone number you wish to send a text to.
7. In the TD field, type D and click the Write button.
8. Note the number in the PH field; it is the XBee Smart Modem phone number, which you see
when it sends an SMS to your phone.
9. Click the Consoles working mode button

on the toolbar to open a serial console to the

device. For instructions on using the Console, see the AT console topic in the XCTU User Guide.
10. Click the Open button

to open a serial connection to the device.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

28

Connection examples

Send an SMS message to a phone

11. Click in the left pane of the Console log, type hello world and press Enter. The XBee Smart
Modem sends the message to the destination phone number set by the P# command.
Note If you are receiving individual characters, verify that you set TD correctly.
12. When the phone receives the text, you can see that the sender's phone number matches the
value reported by the XBee Smart Modem with the PH command.
13. On the phone, reply with the text connect with confidence and the XBee Smart Modem
outputs this reply from the UART.

Debugging
If you experience problems with the settings in this example, you can load the default settings in
XCTU:
1. On the Configuration toolbar, click the Default button

to load the default values

established by the firmware, and click Yes to confirm.
2. Factory settings are loaded but not written to the device. To write them, click the Write button
on the toolbar.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

29

Connection examples

Perform a (GET) HTTP request

Perform a (GET) HTTP request
You can use the XBee Smart Modem to perform a GET Hypertext Transfer Protocol (HTTP) request
using XCTU. HTTP is an application-layer protocol that runs over TCP. This example uses httpbin.org/
as the target website that responds to the HTTP request.
To perform a GET request:
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and Add a device.
3. Click the Configuration working mode

button.

4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. To enter the destination address of the target website, in the DL field, type httpbin.org and
click the Write button

.

6. To enter the HTTP request port number, in the DE field, type 50 and click the Write button.
Hexadecimal 50 is 80 in decimal.
7. To switch to TCP communication, in the IP field, select 1 and click the Write button.
8. To move into Transparent mode, in the AP field, select 0 and click the Write button.
9. Wait for the AI (Association Indication) value to change to 0 (Connected to the Internet).
10. Click the Consoles working mode button

on the toolbar.

11. From the AT console, click the Add new packet button

in the Send packets dialog. The

Add new packet dialog appears.
12. Enter the name of the data packet.
13. Type the following data in the ASCII input tab:
GET /ip HTTP/1.1
Host: httpbin.org
14. Click the HEX input tab and add 0A (zero A) after each 0D (zero D), and add an additional 0D 0A
at the end of the message body. For example, copy and past the following text into the HEX
input tab:
47 45 54 20 2F 69 70 20 48 54 54 50 2F 31 2E 31 0D 0A 48 6F 73 74 3A 20 68 74 74 70 62 69 6E
2E 6F 72 67 0D 0A 0D 0A
Note The HTTP protocol requires an empty line (a line with nothing preceding the CRLF) to terminate
the request.
15. Click Add packet.
16. Click the Open button

.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

30

Connection examples

Perform a (GET) HTTP request

17. Click Send selected packet.
18. A GET HTTP response from httpbin.org appears in the Console log.

Debugging
If you experience problems with the settings in this example, you can load the default settings in
XCTU:
1. On the Configuration toolbar, click the Default button

to load the default values

established by the firmware, and click Yes to confirm.
2. Factory settings are loaded but not written to the device. To write them, click the Write button
on the toolbar.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

31

Connection examples

Get started with CoAP

Get started with CoAP
Constrained Application Protocol (CoAP) is based on UDP connection and consumes low power to
deliver similar functionality to HTTP. This guide contains information about sending GET, POST, PUT
and DELETE operations by using the Coap Protocol with XCTU and Python code working with the XBee
Smart Modem and Coapthon library (Python 2.7 only).
The Internet Engineering Task Force describes CoAP as:
The protocol is designed for machine-to-machine (M2M) applications such as smart energy and
building automation. CoAP provides a request/response interaction model between application
endpoints, supports built-in discovery of services and resources, and includes key concepts of
the Web such as URIs and Internet media types. CoAP is designed to easily interface with HTTP
for integration with the Web while meeting specialized requirements such as multicast
support, very low overhead, and simplicity for constrained environments (source).

CoAP terms
When describing CoAP, we use the following terms:
Term

Meaning

Method

COAP's method action is similar to the HTTP method. This guide discusses the GET,
POST, PUT and DELETE methods. With these methods, the XBee Smart Modem can
transport data and requests.

URI

URI is a string of characters that identifies a resource served at the server.

Token

A token is an identifier of a message. The client uses the token to verify if the received
message is the correct response to its query.

Payload

The message payload is associated with the POST and PUT methods. It specifies the
data to be posted or put to the URI resource.

Message ID The message ID is also an identifier of a message. The client matches the message ID
between the response and query.

CoAP quick start example
The following diagram shows the message format for the CoAP protocol; see ISSN: 2070-1721 for
details:

This is an example GET request:
44 01 C4 09 74 65 73 74 B7 65 78 61 6D 70 6C 65

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

32

Connection examples

Get started with CoAP

The following table describes the fields in the GET request.
Field

HEX

Bits

Meaning

Ver

44

01

Version 01, which is mandatory here.

T

00

Type 0: confirmable.

TKL

0100

Token length: 4.

Code

01

000 00001

Code: 0.01, which indicates the GET method.

Message ID

C4 09

2 Bytes equal
to hex at left

Message ID. The response message will have the
same ID. This can help out identification.

Token

74 65 73 74 4 Bytes equal
to hex at left

Token. The response message will have the same
token. This can help out identification.

Option delta

B7

1011

Delta option: 11 indicates the option data is Uri-Path.

0111

Delta length: 7 indicates there are 7 bytes of data
following as a part of this delta option.

Option length
Option value

65 78 61 6D 7 Bytes equal
70 6C 65
to hex at left

Example.

Configure the device
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and click the Configuration working mode

button.

3. Add the XBee Smart Modem to XCTU; see Add a device.
4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. To switch to UDP communication, in the IP field, select 0 and click the Write button

.

6. To set the target IP address that the XBee Smart Modem will talk to, in the DL field type
52.43.121.77and click the Write button

. A CoAP server is publicly available at address

52.43.121.77.
7. To set the XBee Smart Modem to send data to port 5683 in decimal, in the DE field, type 1633
and click the Write button.
8. To move into Transparent mode, in the AP field, select 0 and click the Write button.
9. Wait for the AI (Association Indication) value to change to 0 (Connected to the Internet). You
can click Read

to get an update on the AI value.

Example: manually perform a CoAP request
Follow the steps in Configure the device prior to this example. This example performs the CoAP
GET request:

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

33

Connection examples

Get started with CoAP

n

Method: GET

n

URI: example

n

Given message token: test

1. Click the Consoles working mode button

on the toolbar to add a customized packet.

2. From the AT console, click the Add new packet button

in the Send packets dialog. The

Add new packet dialog appears.
3. Click the HEX tab and type the name of the data packet: GET_EXAMPLE.
4. Copy and past the following text into the HEX input tab:
44 01 C4 09 74 65 73 74 B7 65 78 61 6D 70 6C 65
This is the CoAP protocol message decomposed by bytes to perform a GET request on an
example URI with a token test.
5. Click Add packet.
6. Click the Open button

.

7. Click Send selected packet. The message is sent to the public CoAP server configured in
Configure the device. A response appears in the Console log. Blue text is the query, red text is
the response.
The payload is Get to uri: example, which specifies that this is a successful CoAP GET to URI end
example, which was specified in the query.
Click the Close button to terminate the serial connection.

Example: use Python to generate a CoAP message
This example illustrates how the CoAP protocol can perform GET/POST/PUT/DELETE requests
similarly to the HTTP protocol and how to do this using the XBee Smart Modem. In this example, the
XBee Smart Modem talks to a CoAP Digi Server. You can use this client code to provide an abstract
wrapper to generate a CoAP message that commands the XBee Smart Modem to talk to the remote
CoAP server.
Note It is crucial to configure the XBee Smart Modem settings. See Configure the device and follow
the steps. You can target the IP address to a different CoAP public server.
1. Install Python 2.7. The Installation guide is located at: python.org/downloads/.
2. Download and install the CoAPthon library in the python environment from
pypi.python.org/pypi/CoAPthon.
3. Download these two .txt files: Coap.txt and CoapParser.txt. After you download them, open the
files in a text editor and save them as .py files.
4. In the folder that you place the Coap.py and CoapParser.py files, press Shift + right-click and
then click Open command window.
5. At the command prompt, type python Coap.py and press Enter to run the program.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

34

Connection examples

Get started with CoAP

6. Type the USB port number that the XBee Smart Modem is connected to and press Enter. Only
the port number is required, so if the port is COM19, type 19.
Note If you do not know the port number, open XCTU and look at the XBee Smart Modem in the Radio
Modules list. This view provides the port number and baud rate, as in the figure below where the baud
rate is 9600 b/s.

7. Type the baud rate and press Enter. You must match the device's current baud rate.
XCTU provides the current baud rate in the BD Baud Rate field. In this example you would type
9600.
8. Press Y if you want an auto-generated example. Press Enter to build your own CoAP request.
9. If you press Y it generates a message with:
n

Method: POST

n

URI: example

n

payload: hello world

n

token: test

The send and receive message must match the same token and message id. Otherwise, the client reattempts the connection by sending out the request.
In the following figure, the payload contains the server response to the query. It shows the results for
when you press Enter rather than Y.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

35

Connection examples

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

Get started with CoAP

36

Connection examples

Connect to a TCP/IP address

Connect to a TCP/IP address
The XBee Smart Modem can send and receive TCP messages while in Transparent mode; see
Transparent operating mode.
Note You can use this example as a template for sending and receiving data to or from any
TCP/IP server.
The following table explains the AT commands that you use in this example.
Command

Value

Description

IP (IP
Protocol)

1

Set the expected transmission mode to TCP communication.

DL
(Destination
IP Address)



The target IP address that you send and receive from. For example, a
data logging server’s IP address that you want to send
measurements to.

DE
(Destination
Port)

 This is represented as a hexadecimal value.

To connect to a TCP/IP address:
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and Add a device.
3. Click the Configuration working mode

button.

4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. In the IP field, select 1 and click the Write button

.

6. In the DL field, type the  and click the Write button. The target IP address
is the IP address that you send and receive from.
7. In the DE field, type the , converted to hexadecimal, and click the Write
button.
8. Exit Command mode.
After exiting Command mode, any UART data sent to the device is sent to the destination IP address
and port number after the RO (Packetization Timeout) occurs.

Debugging
If you experience problems with the settings in this example, you can load the default settings in
XCTU:

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

37

Connection examples

1. On the Configuration toolbar, click the Default button

Connect to a TCP/IP address

to load the default values

established by the firmware, and click Yes to confirm.
2. Factory settings are loaded but not written to the device. To write them, click the Write button
on the toolbar.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

38

Connection examples

Get started with MQTT

Get started with MQTT
MQ Telemetry Transport (MQTT) is a messaging protocol that is ideal for the Internet of Things (IoT)
due to a light footprint and its use of the publish-subscribe model. In this model, a client connects to a
broker, a server machine responsible for receiving all messages, filtering them, and then sending
messages to the appropriate clients.
The first two MQTT examples do not involve the XBee Smart Modem. They demonstrate using the
MQTT libraries because those libraries are required for Use MQTT over the XBee Cellular Modem with
a PC.
The examples in this guide assume:
n Some knowledge of Python.
n

An integrated development environment (IDE) such as PyCharm, IDLE or something similar.

The examples require:
n An XBee Smart Modem.
n

A compatible development board, such as the XBIB-U.

n

XCTU. See Configure the device using XCTU.

n

That you install Python on your computer. You can download Python from:
https://www.python.org/downloads/.

n

That you install the pyserial and paho-mqtt libraries to the Python environment. If you use
Python 2, install these libraries from the command line with pip install pyserial and pip
install paho-mqtt. If you use Python 3, use pip3 install pyserial and pip3 install paho-mqtt.

n

The full MQTT library source code, which includes examples and tests, which is available in the
paho-mqtt github repository at https://github.com/eclipse/paho.mqtt.python. To download this
repository you must have Git installed.

Example: MQTT connect
This example provides insight into the structure of packets in MQTT as well as the interaction
between the client and broker. MQTT uses different packets to accomplish tasks such as connecting,
subscribing, and publishing. You can use XCTU to perform a basic example of sending a broker a
connect packet and receiving the response from the server, without requiring any coding. This is a
good way to see how the client interacts with the broker and what a packet looks like. The following
table is an example connect packet:
Description

Hex value

CONNECT packet fixed header
byte 1

Control packet type

0x10

byte 2

Remaining length

0x10

CONNECT packet variable header
Protocol name

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

39

Connection examples

Get started with MQTT

Description

Hex value

byte 1

Length MSB (0)

0x00

byte 2

Length LSB (4)

0x04

byte 3

(M)

0x4D

byte 4

(Q)

0x51

byte 5

(T)

0x54

byte 6

(T)

0x54

Level (4)

0x04

CONNECT flags byte, see the table below for the bits.

0X02

byte 9

Keep Alive MSB (0)

0X00

byte 10

Keep Alive LSB (60)

0X3C

byte 11

Length MSB (0)

0x00

byte 12

Length LSB (4)

0x04

byte 13

(D)

0x44

byte 14

(I)

0x49

byte 15

(G)

0x47

byte 16

(I)

0x49

Protocol level
byte 7
Connect flags
byte 8
Keep alive

Client ID

The following table describes the fields in the packet:
Field name

Description

Protocol Name The connect packet starts with the protocol name, which is MQTT. The length of
the protocol name (in bytes) is immediately before the name itself.
Protocol Level

Refers to the version of MQTT in use, in this case a value of 4 indicates MQTT
version 3.1.1.

Connect Flags

Indicate certain aspects of the packet. For simplicity, this example only sets the
Clean Session flag, which indicates to the client and broker to discard any previous
session and start a new one.

Keep Alive

How often the client pings the broker to keep the connection alive; in this example
it is set to 60 seconds.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

40

Connection examples

Get started with MQTT

Field name

Description

Client ID

The length of the ID (in bytes) precedes the ID itself. Each client connecting to a
broker must have a unique client ID. In the example, the ID is DIGI. When using the
Paho MQTT Python libraries, a random alphanumeric ID is generated if you do not
specify an ID.

The following table provides the CONNECT flag bits from byte 8, the CONNECT flags byte.
CONNECT Flag Bit(s)

Bit 7

User name flag

0

Password flag

Bit 6

Bit 5

Bit 4

Bit 3

0

0

Bit 2

Bit 1

Bit 0

0

Will retain

0

Will QoS
Will flag

0

Clean session

1

Reserved

0

Send a connect packet
Now that you know what a connect packet looks like, you can send a connect packet to a broker and
view the response. Open XCTU and click the Configuration working mode button.
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and click the Configuration working mode

button.

3. Add the XBee Smart Modem to XCTU; see Add a device.
4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. In the AP field, set Transparent Mode to [0] if it is not already and click the Write button.
6. In the DL field, type the IP address of the broker you wish to use. This example uses
198.41.30.241, which is the IP address for m2m.eclipse.org, a public MQTT broker.
7. In the DE field, type 75B and set the port that the broker uses. This example uses 75B, because
the default MQTT port is 1883 (0x75B).
8. Once you have entered the required values, click the Write button to write the changes to the
XBee Smart Modem.
9. Click the Consoles working mode button

on the toolbar to open a serial console to the

device. For instructions on using the Console, see the AT console topic in the XCTU User Guide.
10. Click the Open button

to open a serial connection to the device.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

41

Connection examples

11. From the AT console, click the Add new packet button

Get started with MQTT

in the Send packets dialog. The

Add new packet dialog appears.
12. Enter the name of the data packet. Name the packet connect_frame or something similar.
13. Click the HEX input tab and type the following (these values are the same values from the
table in Example: MQTT connect):
10 10 00 04 4D 51 54 54 04 02 00 3C 00 04 44 49 47 49

14. Click Add packet. The new packet appears in the Send packets list.
15. Click the packet in the Send packets list.
16. Click Send selected packet.
17. A CONNACK packet response from the broker appears in the Console log. This is a connection
acknowledgment; a successful response should look like this:

You can verify the response from the broker as a CONNACK by comparing it to the structure of a
CONNACK packet in the MQTT documentation, which is available at http://docs.oasisopen.org/mqtt/mqtt/v3.1.1/os/mqtt-v3.1.1-os.html#_Toc398718081).

Example: send messages (publish) with MQTT
A basic Python example of a node publishing (sending) a message is:

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

42

Connection examples

Get started with MQTT

mqttc = mqtt.Client("digitest") # Create instance of client with client ID
“digitest”
mqttc.connect("m2m.eclipse.org", 1883) # Connect to (broker, port,
keepalive-time)
mqttc.loop_start() # Start networking daemon
mqttc.publish("digitest/test1", "Hello, World!") # Publish message to
“digitest /test1” topic
mqttc.loop_stop() # Kill networking daemon

Note You can easily copy and paste code from the online version of this guide. Use caution with the
PDF version, as it may not maintain essential indentations.
This example imports the MQTT library, allowing you to use the MQTT protocol via APIs in the library,
such as the connect(), subscribe(), and publish() methods.
The second line creates an instance of the client, named mqttc. The client ID is the argument you
passed in: digitest (this is optional).
In line 3, the client connects to a public broker, in this case m2m.eclipse.org, on port 1883 (the default
MQTT port, or 8883 for MQTT over SSL). There are many publicly available brokers available, you can
find a list of them here: https://github.com/mqtt/mqtt.github.io/wiki/brokers.
Line 4 starts the networking daemon with client.loop_start() to handle the background
network/data tasks.
Finally, the client publishes its message Hello, World! to the broker under the topic
digitest/backlog/test1. Any nodes (devices, phones, computers, even microcontrollers) subscribed to
that same topic on the same broker receive the message.
Once no more messages need to be published, the last line stops the network daemon with
client.loop_stop().

Example: receive messages (subscribe) with MQTT
This example describes how a client would receive messages from within a specific topic on the
broker:
import paho.mqtt.client as mqtt
def on_connect(client, userdata, flags, rc): # The callback for when the
client connects to the broker
print("Connected with result code {0}".format(str(rc))) # Print result
of connection attempt
client.subscribe("digitest/test1") # Subscribe to the topic
“digitest/test1”, receive any messages published on it
def on_message(client, userdata, msg): # The callback for when a PUBLISH
message is received from the server.
print("Message received-> " + msg.topic + " " + str(msg.payload)) #
Print a received msg
client = mqtt.Client("digi_mqtt_test") # Create instance of client with
client ID “digi_mqtt_test”
client.on_connect = on_connect # Define callback function for successful
connection
client.on_message = on_message # Define callback function for receipt of a

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

43

Connection examples

Get started with MQTT

message
# client.connect("m2m.eclipse.org", 1883, 60) # Connect to (broker, port,
keepalive-time)
client.connect('127.0.0.1', 17300)
client.loop_forever() # Start networking daemon

Note You can easily copy and paste code from the online version of this guide. Use caution with the
PDF version, as it may not maintain essential indentations.
The first line imports the library functions for MQTT.
The functions on_connect and on_message are callback functions which are automatically called by
the client upon connection to the broker and upon receiving a message, respectively.
The on_connect function prints the result of the connection attempt, and performs the subscription.
It is wise to do this in the callback function as it guarantees the attempt to subscribe happens only
after the client is connected to the broker.
The on_message function prints the received message when it comes in, as well as the topic it was
published under.
In the body of the code, we:
n Instantiate a client object with the client ID digi_mqtt_test.
n

Define the callback functions to use upon connection and upon message receipt.

n

Connect to an MQTT broker at m2m.eclipse.org, on port 1883 (the default MQTT port, or 8883
for MQTT over SSL) with a keepalive of 60 seconds (this is how often the client pings the broker
to keep the connection alive).

The last line starts a network daemon that runs in the background and handles data transactions and
messages, as well as keeping the socket open, until the script ends.

Use MQTT over the XBee Cellular Modem with a PC
To use this MQTT library over an XBee Smart Modem, you need a basic proxy that transfers a payload
received via the MQTT client’s socket to the serial or COM port that the XBee Smart Modem is active
on, as well as the reverse; transfer of a payload received on the XBee Smart Modem’s serial or COM
port to the socket of the MQTT client. This is simplest with the XBee Smart Modem in Transparent
mode, as it does not require code to parse or create API frames, and not using API frames means
there is no need for them to be queued for processing.
1. To put the XBee Cellular Modem in Transparent mode, set AP to 0.
2. Set DL to the IP address of the broker you want to use.
3. Set DE to the port to use, the default is 1883 (0x75B). This sets the XBee Smart Modem to
communicate directly with the broker, and can be performed in XCTU as described in Example:
MQTT connect.
4. You can make the proxy with a dual-threaded Python script, a simple version follows:
import threading
import serial
import socket
def setup():

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

44

Connection examples

Get started with MQTT

"""
This function sets up the variables needed, including the serial port,
and it's speed/port settings, listening socket, and localhost adddress.
"""
global clisock, cliaddr, svrsock, ser
# Change this to the COM port your XBee Cellular module is using. On
# Linux, this will be /dev/ttyUSB#
comport = 'COM44'
# This is the default serial communication speed of the XBee Cellular
# module
comspeed = 115200
buffer_size = 4096 # Default receive size in bytes
debug_on = 0 # Enables printing of debug messages
toval = None # Timeout value for serial port below
# Serial port object for XBCell modem
ser = serial.Serial(comport,comspeed,timeout=toval)
# Listening socket (accepts incoming connection)
svrsock = socket.socket(socket.AF_INET,socket.SOCK_STREAM)
# Allow address reuse on socket (eliminates some restart errors)
svrsock.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1)
clisock = None
cliaddr = None # These are first defined before thread creation
addrtuple = ('127.0.0.1', 17300) # Address tuple for localhost
# Binds server socket to localhost (allows client program connection)
svrsock.bind(addrtuple)
svrsock.listen(1) # Allow (1) connection
def ComReaderThread():
"""
This thread listens on the defined serial port object ('ser') for data
from the modem, and upon receipt, sends it out to the client over the
client socket ('clisock').
"""
global clisock
while (1):
resp = ser.read() ## Read any available data from serial port
print("Received {} bytes from modem.".format(len(resp)))
clisock.sendall(resp) # Send RXd data out on client socket
print("Sent {} byte payload out socket to client.".format(len
(resp)))
def SockReaderThread():
"""
This thread listens to the MQTT client's socket and upon receiving a
payload, it sends this data out on the defined serial port ('ser') to
the
modem for transmission.
"""
global clisock
while (1):
data = clisock.recv(4096) # RX data from client socket
# If the RECV call returns 0 bytes, the socket has closed
if (len(data) == 0):
print("ERROR - socket has closed. Exiting socket reader
thread.")

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

45

Connection examples

Get started with MQTT

return 1 # Exit the thread to avoid a loop of 0-byte receptions
else:
print("Received {} bytes from client via socket.".format(len
(data)))
print("Sending payload to modem...")
bytes_wr = ser.write(data) # Write payload to modem via
UART/serial
print("Wrote {} bytes to modem".format(bytes_wr))
def main():
setup() # Setup the serial port and socket
global clisock, svrsock
if (not clisock): # Accept a connection on 'svrsock' to open 'clisock'
print("Awaiting ACCEPT on server sock...")
(clisock,cliaddr) = svrsock.accept() # Accept an incoming
connection
print("Connection accepted on socket")
# Make thread for ComReader
comthread = threading.Thread(target=ComReaderThread)
comthread.start() # Start the thread
# Make thread for SockReader
sockthread = threading.Thread(target=SockReaderThread)
sockthread.start() # Start the thread
main()

Note This script is a general TCP-UART proxy, and can be used for other applications or scripts that
use the TCP protocol. Its functionality is not limited to MQTT.
Note You can easily copy and paste code from the online version of this guide. Use caution with the
PDF version, as it may not maintain essential indentations.
This proxy script waits for an incoming connection on localhost (127.0.0.1), on port 17300. After
accepting a connection, and creating a socket for that connection (clisock), it creates two threads,
one that reads the serial or COM port that the XBee Smart Modem is connected to, and one that
reads the socket (clisock), that the MQTT client is connected to.
With:
n

The proxy script running

n

The MQTT client connected to the proxy script via localhost (127.0.0.1)

n

The XBee Smart Modem connected to the machine via USB and properly powered

n

AP, DL, and DE set correctly

the proxy acts as an intermediary between the MQTT client and the XBee Smart Modem, allowing the
MQTT client to use the data connection provided by the device.
Think of the proxy script as a translator between the MQTT client and the XBee Smart Modem. The
following figure shows the basic operation.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

46

Connection examples

Software libraries

The thread that reads the serial port forwards any data received onward to the client socket, and the
thread reading the client socket forwards any data received onward to the serial port. This is
represented in the figure above.
The proxy script needs to be running before running an MQTT publish or subscribe script.
1. With the proxy script running, run the subscribe example from Example: receive messages
(subscribe) with MQTT, but change the connect line from client.connect("m2m.eclipse.org",
1883, 60) to client.connect("127.0.0.1", port=17300, keepalive=20). This connects the
MQTT client to the proxy script, which in turn connects to a broker via the XBee Smart
Modem’s internet connection.
2. Run the publish example from Example: send messages (publish) with MQTT in a third Python
instance (while the publish script is running you will have three Python scripts running at the
same time).
The publish script runs over your computer’s normal Internet connection, and does not use the XBee
Smart Modem. You are able to see your published message appear in the subscribe script’s output
once it is received from the broker via the XBee Smart Modem. If you watch the output of the proxy
script during this process you can see the receptions and transmissions taking place.
The proxy script must be running before you run the subscribe and publish scripts. If you stop the
subscribe script, the socket closes, and the proxy script shows an error. If you try to start the proxy
script after starting the subscribe script, you may also see a socket error. To avoid these errors, it is
best to start the scripts in the correct order: proxy, then subscribe, then publish.

Software libraries
One way to communicate with the XBee device is by using a software library. The libraries available
for use with the XBee Smart Modem include:
n XBee Java library
n

XBee Python library

The XBee Java Library is a Java API. The package includes the XBee library, its source code and a
collection of samples that help you develop Java applications to communicate with your XBee devices.
The XBee Python Library is a Python API that dramatically reduces the time to market of XBee
projects developed in Python and facilitates the development of these types of applications, making it
an easy process.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

47

Get started with MicroPython
This guide provides an overview of how to use MicroPython with the XBee Smart Modem. For in-depth
information and more complex code examples, refer to the Digi MicroPython Programming Guide.
Continue with this guide for simple examples to get started using MicroPython on the XBee Smart
Modem.

About MicroPython
MicroPython is an open-source programming language based on Python 3, with much of the same
syntax and functionality, but modified to fit on small devices with limited hardware resources, such as
microcontrollers, or in this case, a cellular modem.

Why use MicroPython
MicroPython enables on-board intelligence for simple sensor or actuator applications using digital and
analog I/O. MicroPython can help manage battery life. Cryptic readings can be transformed into useful
data, excess transmissions can be intelligently filtered out, modern sensors and actuators can be
employed directly, and logic can glue inputs and outputs together in an intelligent way.
For more information about MicroPython, see www.micropython.org.
For more information about Python, see www.python.org.

MicroPython on the XBee Smart Modem
The XBee Smart Modem has MicroPython running on the device itself. You can access a MicroPython
prompt from the XBee Smart Modem when you install it in an appropriate development board (XBDB
or XBIB), and connect it to a computer via a USB cable.
Note MicroPython does not work with SPI.
The examples in this guide assume:
n You have XCTU on your computer. See Configure the device using XCTU.
n

You have a terminal program installed on your computer. We recommend using the Use the
MicroPython Terminal in XCTU. This requires XCTU 6.3.7 or higher.

n

You have an XBee Smart Modem installed in an appropriate development board such as an
XBIB-U-DEV or an XBIB-2.

Note Most examples in this guide require the XBIB-U-DEV board.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

48

Get started with MicroPython

Use XCTU to enter the MicroPython environment

n

The XBee Smart Modem is connected to the computer via a USB cable and XCTU recognizes it.

n

The board is powered by an appropriate power supply, 12 VDC and at least 1.1 A.

Use XCTU to enter the MicroPython environment
To use the XBee Smart Modem in the MicroPython environment:
1. Use XCTU to add the device(s); see Configure the device using XCTU and Add a device.
2. The XBee Smart Modem appears as a box in the Radio Modules information panel. Each
module displays identifying information about itself.
3. Click this box to select the device and load its current settings.
4. To set the device's baud rate to 115200 b/s, in the BD field select 115200 [7] or higher and
click the Write button

. We recommend using flow control to avoid data loss, especially

when pasting large amounts of code/text.
5. To put the XBee Smart Modem into MicroPython mode, in the AP field select MicroPython
REPL [4] and click the Write button

.

6. Note what COM port(s) the XBee Smart Modem is using, because you will need this information
when you use terminal communication. The Radio Modules information panel lists the COM
port in use.

Use the MicroPython Terminal in XCTU
You can use the MicroPython Terminal to communicate with the XBee Smart Modem when it is in
MicroPython mode.1 This requires XCTU 6.3.7 or higher. To enter MicroPython mode, follow the steps
in Use XCTU to enter the MicroPython environment. To use the MicroPython Terminal:
1. Click the Tools drop-down menu

and select MicroPython Terminal. The terminal opens.

2. Click Open. If you have not already added devices to XCTU:
a. In the Select the Serial/USB port area, click the COM port that the device uses.
b. Verify that the baud rate and other settings are correct.
3. Click OK. The Open icon changes to Close

, indicating that the device is properly connected.

4. Press Ctrl+B to get the MicroPython version banner and prompt.
You can now type or paste MicroPython commands at the >>> prompt.

Troubleshooting
If you receive No such port: 'Port is already in use by other applications.' in the MicroPython
Terminal close any other console sessions open inside XCTU and close any other serial terminal
programs connected to the device, then retry the MicroPython connection in XCTU.
If the device seems unresponsive, try pressing Ctrl+C to end any running programs.

1See Other terminal programs if you do not use the MicroPython Terminal in XCTU.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

49

Get started with MicroPython

Example: hello world

You can use the +++ escape sequence and look for an OK for confirmation that you have the correct
baud rate.

Example: hello world
1. At the MicroPython >>> prompt, type the Python command: print("Hello, World!")
2. Press Enter to execute the command. The terminal echos back Hello, World!.

Example: turn on an LED
1. Note the DS4 LED on the XBIB board. The following image highlights it in a red box. The LED is
normally off.

2. At the MicroPython >>> prompt, type the commands below, pressing Enter after each one.
After entering the last line of code, the LED illuminates. Anything after a # symbol is a
comment, and you do not need to type it.
Note You can easily copy and paste code from the online version of this guide. Use caution with the
PDF version, as it may not maintain essential indentations.
import machine
from machine import Pin
led = Pin("D4", Pin.OUT, value=0) # Makes a pin object set to output 0.
# One might expect 0 to mean OFF and 1 to mean ON, and this is normally the
case.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

50

Get started with MicroPython

Example: code a request help button

# But the LED we are turning on and off is setup as what is# known as
"active low".
# This means setting the pin to 0 allows current to flow through the LED and
then through the pin, to ground.

3. To turn it off, type the following and press Enter:
led.value(1)

You have successfully controlled an LED on the board using basic I/O.

Example: code a request help button
This example provides a fast, deep dive into MicroPython designed to let you see some of the powerful
things it can do with minimal code. It is not meant as a tutorial; for in-depth examples refer to the Digi
MicroPython Programming Guide.
Many stores have help buttons in their aisles that a customer can press to alert the store staff that
assistance is required in that aisle. You can implement this type of system using the Digi XBee Smart
Modem, and this example provides the building blocks for such a system. This example, based on SMS
paging, can have many other uses such as alerting someone with a text to their phone if a water
sensor in a building detects water on the floor, or if a temperature sensor reports a value that is too
hot or cold relative to normal operation.

Enter MicroPython paste mode
In the following examples it is helpful to know that MicroPython supports paste mode, where you can
copy a large block of code from this user guide and paste it instead of typing it character by character.
To use paste mode:
1. Copy the code you want to run. For example, copy the following code that is the code from the
LED example:
from machine import Pin
led = Pin("D4", Pin.OUT, value=0)

Note You can easily copy and paste code from the online version of this guide. Use caution with the
PDF version, as it may not maintain essential indentations.
2. In the terminal, at the MicroPython >>> prompt type Ctrl+E to enter paste mode. The terminal
displays paste mode; Ctrl-C to cancel, Ctrl-D to finish.
3. The code appears in the terminal occupying four lines, each line starts with its line number and
three = symbols. For example line 1 starts with 1===.
4. If the code is correct, press Ctrl+D to run the code and you should once again see the DS4 LED
turn on. If you get a Line 1 SyntaxError: invalid syntax error, see Syntax error at line 1.
If you wish to exit paste mode without running the code, for example, or if the code did not
copy correctly, press Ctrl+C to cancel and return to the normal MicroPython >>> prompt.
5. Next turn the LED off. Copy the code below:
from machine import Pin
led = Pin("D4", Pin.OUT, value=1)

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

51

Get started with MicroPython

Example: code a request help button

print("DS4 LED now OFF!")
print("Paste Mode Successful!")

6. Press Ctrl+E to enter paste mode.
7. Press Ctrl + Shift + V or right-click in the Terminal and select Paste to paste the copied code.
8. If the code is correct, press Ctrl+D to run it. The LED should turn off and you should see two
confirmation messages print to the screen.

Catch a button press
For this part of the example, you write code that responds to a button press on the XBIB-U-DEV board
that comes with the XBee Smart Modem Development Kit. The code monitors the pin connected to
the button on the board labeled SW2.

On the board you see DIO0 written below SW2, to the left of the button. This represents the pin that
the button is connected to.
In MicroPython, you will create a pin object for the pin that is connected to the SW2 button. When you
create the pin object, the DIO0 pin is called D0 for short.
The loop continuously checks the value on that pin and once it goes to 0 (meaning the button has been
pressed) a print() call prints the message Button pressed! to the screen.
At the MicroPython >>> prompt, copy the following code and enter it into MicroPython using paste
mode (Ctrl+E), right-click in the Terminal, select Paste to paste the copied code, and press Ctrl+D to
run the code.
# Import the Pin module from machine, for simpler syntax.
from machine import Pin
# Create a pin object for the pin that the button "SW2" is connected to.
dio0 = Pin("D0", Pin.IN, Pin.PULL_UP)
# Give feedback to inform user a button press is needed.
print("Waiting for SW2 press...")

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

52

Get started with MicroPython

Example: code a request help button

# Create a WHILE loop that checks for a button press.
while (True):
if (dio0.value() == 0): # Once pressed.
print("Button pressed!") # Print message once pressed.
break # Exit the WHILE loop.
# When you press SW2, you should see "Button pressed!" printed to the
screen.
# You have successfully performed an action in response to a button press!

Note You can easily copy and paste code from the online version of this guide. Use caution with the
PDF version, as it may not maintain essential indentations.
Note If you have problems pasting the code, see Syntax error at line 1. For SMS failures, see Error
Failed to send SMS.

Send a text (SMS) when the button is pressed
After creating a while loop that checks for a button press, add sending an SMS to your code. Instead of
printing Button pressed! to the screen, this code sends Button pressed to a cell phone as a text
(SMS) message.
To accomplish this, use the sms_send() method, which sends a string to a given phone number. It
takes the arguments in the following order:
1. 
2. 
Before you run this part of the example, you must create a variable that holds the phone number of
the cell phone or mobile device you want to receive the SMS.
1. To do this, at the MicroPython >>> prompt, type the following command, replacing 1123456789
with the full phone number (no dashes, spaces, or other symbols) and press Enter:
ph = 1123456789

2. After you create this ph variable with your phone number, copy the code below and enter it
into MicroPython using paste mode (Ctrl+E) and then run it.
from machine import Pin
import network # Import network module
import time
c = network.Cellular() # initialize cellular network parameter
dio0 = Pin("D0", Pin.IN, Pin.PULL_UP)
while not c.isconnected(): # While no network connection.
print("Waiting for connection to cell network...")
time.sleep(5)
print("Connected.")
# Give feedback to inform user a button press is needed.
print("Waiting for SW2 press...")
while (True):
if (dio0.value() == 0):
# When SW2 is pressed, the module will send an SMS
# message saying "Button pressed" to the given target cell phone

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

53

Get started with MicroPython

Example: code a request help button

number.
try:
c.sms_send(ph, 'Button Pressed')
print("Sent SMS successfully.")
except OSError:
print("ERROR- failed to send SMS.")
# Exit the WHILE loop.
break

Note You can easily copy and paste code from the online version of this guide. Use caution with the
PDF version, as it may not maintain essential indentations.
Note If you have problems pasting the code, see Syntax error at line 1. For SMS failures, see Error
Failed to send SMS.

Add the time the button was pressed
After you add the ability to send an SMS to the code, add functionality to insert the time at which the
button was pressed into the SMS that is sent. To accomplish this:
1. Create a UDP socket with the socket() method.
2. Save the IP address and port of the time server in the addr variable.
3. Connect to the time server with the connect() method.
4. Send hello to the server to prompt it to respond with the current date and time.
5. Receive and store the date/time response in the buf variable.
6. Send an SMS in the same manner as before using the sms_send() method, except that you add
the time into the SMS message, such that the message reads: [Button pressed at: YYYY-MMDD HH:MM:SS]
To verify that your phone number is still in the memory, at the MicroPython >>> prompt, type ph and
press Enter.
If MicroPython responds with your number, copy the following code and enter it into MicroPython
using paste mode and then run it. If it returns an error, enter your number again as shown in Send a
text (SMS) when the button is pressed. With your phone number in memory in the ph variable, copy
the code below and enter it into MicroPython using paste mode (Ctrl+E) and then run it.
from machine import Pin
import network
import usocket
import time
c = network.Cellular()
dio0 = Pin("D0", Pin.IN, Pin.PULL_UP)
while not c.isconnected(): # While no network connection.
print("Waiting for connection to cell network...")
time.sleep(5)
print("Connected.")
# Give feedback to inform user a button press is needed.
print("Waiting for SW2 press...")
while (1):
if (dio0.value() == 0):

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

54

Get started with MicroPython

Exit MicroPython mode

# When button pressed, now the module will send "Button Press" AND
# the time at which it was pressed in an SMS message to the given
# target cell phone number.
socketObject = usocket.socket(usocket.AF_INET, usocket.SOCK_DGRAM)
# Connect the socket object to the web server specified in
"address".
addr = ("52.43.121.77", 10002)
socketObject.connect(addr)
bytessent = socketObject.send("hello")
print("Sent %d bytes on socket" % bytessent)
buf = socketObject.recv(1024)
# Send message to the given number. Handle error if it occurs.
try:
c.sms_send(ph, 'Button Pressed at: ' + str(buf))
print("Sent SMS successfully.")
except OSError:
print("ERROR- failed to send SMS.")
# Exit the WHILE loop.
break

Note You can easily copy and paste code from the online version of this guide. Use caution with the
PDF version, as it may not maintain essential indentations.
Now you have a system based on the XBee Smart Modem that sends an SMS in response to a certain
input, in this case a simple button press.
Note If you have problems pasting the code, see Syntax error at line 1. For SMS failures, see Error
Failed to send SMS.

Exit MicroPython mode
To exit MicroPython mode:
1. In the XCTU MicroPython Terminal, click the green Close button

.

2. Click Close at the bottom of the terminal to exit the terminal.
3. In XCTU's Configuration working mode
the Write button

, change AP API Enable to another mode and click

. We recommend changing to Transparent mode [0], as most of the

examples use this mode.

Other terminal programs
If you do not use the MicroPython Terminal in XCTU, you can use other terminal programs to
communicate with the XBee Smart Modem. If you use Microsoft Windows, follow the instructions for
Tera Term, if you use Linux, follow the instructions for picocom. To download these programs:
n Tera Term for Windows; see https://ttssh2.osdn.jp/index.html.en.
n

Picocom for Linux; see https://developer.ridgerun.com/wiki/index.php/Setting_up_Picocom_-_
Ubuntu and for the source code and in-depth information https://github.com/npatefault/picocom.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

55

Get started with MicroPython

Other terminal programs

Tera Term for Windows
With the XBee Smart Modem in MicroPython mode (AP = 4), you can access the MicroPython prompt
using a terminal.
1. Open Tera Term. The Tera Term: New connection window appears.
2. Click the Serial radio button to select a serial connection.
3. From the Port: drop-down menu, select the COM port that the XBee Smart Modem is
connected to.
4. Click OK. The COMxx - Tera Term VT terminal window appears and Tera Term attempts to
connect to the device at a baud rate of 9600 b/s. The terminal will not allow communication
with the device since the baud rate setting is incorrect. You must change this rate as it was
previously set to 115200 b/s.
5. Click Setup and Serial Port. The Tera Term: Serial port setup window appears.

6. In the Tera Term: Serial port setup window, set the parameters to the following values:
n

Port: Shows the port that the XBee Smart Modem is connected on.

n

Baud rate: 115200

n

Data: 8 bit

n

Parity: none

n

Stop: 1 bit

n

Flow control: hardware

n

Transmit delay: N/A

7. Click OK to apply the changes to the serial port settings. The settings should go into effect
right away.
8. To verify that local echo is not enabled and that extra line-feeds are not enabled:
a. In Tera Term, click Setup and select Terminal.
b. In the New-line area of the Tera Term: Serial port setup window, click the
Receive drop-down menu and select CR if it does not already show that value.
c. Make sure the Local echo box is not checked.
9. Click OK.
10. Press Ctrl+B to get the MicroPython version banner and prompt.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

56

Get started with MicroPython

Use picocom in Linux

Now you can type MicroPython commands at the >>> prompt.

Use picocom in Linux
With the XBee Smart Modem in MicroPython mode (AP = 4), you can access the MicroPython prompt
using a terminal.
Note The user must have read and write permission for the serial port the XBee Smart Modem is
connected to in order to communicate with the device.
1. Open a terminal in Linux and type picocom -b 115200 /dev/ttyUSB0. This assumes you have
no other USB-to-serial devices attached to the system.
2. Press Ctrl+B to get the MicroPython version banner and prompt. You can also press Enter to
bring up the prompt.
If you do have other USB-to-serial devices attached:
1. Before attaching the XBee Smart Modem, check the directory /dev/ for any devices named
ttyUSBx, where x is a number. An easy way to list these is to type: ls /dev/ttyUSB*. This
produces a list of any device with a name that starts with ttyUSB.
2. Take note of the devices present with that name, and then connect the XBee Smart Modem.
3. Check the directory again and you should see one additional device, which is the XBee Smart
Modem.
4. In this case, replace /dev/ttyUSB0 at the top with /dev/ttyUSB, where 
is the new number that appeared.
5. It should connect and show Terminal ready.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

57

Get started with MicroPython

Use picocom in Linux

Now you can type MicroPython commands at the >>> prompt.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

58

Technical specifications
Interface and hardware specifications
RF characteristics
Networking specifications
Power requirements
Power consumption
Electrical specifications
Regulatory approvals

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

60
60
60
60
61
61
62

59

Technical specifications

Interface and hardware specifications

Interface and hardware specifications
The following table provides the interface and hardware specifications for the device.
Specification

Value

Dimensions

2.438 x 3.294 cm (0.960 x 1.297 in)

Weight

5 g (0.18 oz)

Operating temperature

-40 to +80 °C

Antenna connector

U.FL for primary and secondary antennas

Digital I/O

13 I/O lines

ADC

4 10-bit analog inputs

RF characteristics
The following table provides the RF characteristics for the device.
Specification

Cellular value

Bluetooth value

Modulation

LTE/4G – QPSK, 16 QAM

QPSK

Transmit power

23 dBm

9 dBm

Receive sensitivity

-102 dBm

-92 dBm

Over-the-air maximum data rate

10 Mb/s

2 Mb/s

Networking specifications
The following table provides the networking and carrier specifications for the device.
Specification

Value

Addressing options

TCP/IP and SMS

Carrier and technology

AT&T LTE Cat 1

Supported bands

2, 4 and 12

Security

SSL/TLS

Power requirements
The following table provides the power requirements for the device.
Specification

Value

Supply voltage range

3.0 to 5.5 VDC

Extended voltage range

2.7 to 5.5 VDC

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

60

Technical specifications

Power consumption

Power consumption
Specification

State

Average
current

2.4 GHz TX

Active transmit @ 3.3 V

70 mA

2.4 GHz RX

Active receive @ 3.3 V

30 mA

Peak current

Cellular Tx+RX current Active transmit, 23 dBm @ 3.3 V 860 mA

1020 mA, Bluetooth
disabled
1080 mA, Bluetooth
enabled

Cellular Tx+RX current Active transmit, 23 dBm @ 5.0 V 555 mA

630 mA, Bluetooth
disabled
680 mA, Bluetooth
enabled

Cellular TX Only
current

Active transmit, 23 dBm @ 3.3 V 680 mA

N/A

Cellular Rx + ACK
current

Active receive @ 3.3 V

530 mA

N/A

Cellular Rx + ACK
current

Active receive @ 5 V

360 mA

N/A

Cellular RX Only
current

Active receive @ 3.3 V

300 mA

N/A

Idle current

Idle/connected, listening @ 3.3
V

110 mA

N/A

Idle current

Idle/connected, listening @ 5 V

75 mA

N/A

Sleep current

Not connected, Deep
Sleep @ 3.3 V

12 µA

N/A

Electrical specifications
The following table provides the electrical specifications for the XBee Smart Modem.
Symbol

Parameter

Condition

VCCMAX Maximum limits
of VCC line
VDD_IO

Internal supply
voltage for I/O

While in deep sleep and
during initial power up

VDD_IO

Internal supply
voltage for I/O

In normal running mode

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

Min

Typical Max

Units

0

5.5

V

Min
(VCC0.3, 3.3)

3.3

V

3.3 V

V

61

Technical specifications

Regulatory approvals

Symbol

Parameter

Condition

Min

VI

Voltage on 5 V
tolerant pins

XBee pin 6

0.3

Min
(5.25,VDD_
IO+2)1

V

0.3

VDD_IO +
0.3

V

Other input pins

Typical Max

Units

VIL

Input low voltage

0.3*VDD_IO V

VIH

Input high
voltage

VOL

Voltage output
low

Sinking 3 mA VDD_IO = 3.3 V

VOH

Voltage output
high

Sourcing 3 mA VDD_IO = 3.3
V

I_IN

Input leakage
current

High Z state I/O connected
to Ground or VDD_IO

0.1

RPU

Internal pull-up
resistor

Enabled

40

kΩ

RPD

Internal pulldown resistor

Enabled

40

kΩ

0.7*VDD_
IO

V
0.2*VDD_IO V

0.8*VDD_
IO

V
100

nA

Regulatory approvals
The following table provides the regulatory and carrier approvals for the device.
Specification

Value

Model

XB3C1

United States

FCC ID: MCQ-XB3C1
Contains FCC ID:RI7XE866A1NA

Innovation, Science and Economic Development Canada (ISED)

IC: 1846A-XB3C1
Contains IC: 5131A-XE866A1NA

Europe (CE)

N/A

RoHS

Lead-free and RoHS compliant

Australia

N/A

Verizon end-device certified

No

AT&T end-device certified

Yes

PTCRB end-device certified

Yes

1Pin 6 is also 5 V tolerant even when the XBee Smart Modem is not powered. We recommend only driving this

pin with 3.3 V for compatibility with other XBee products. The VBUS line is not used to enable/disable USB on
this product.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

62

Hardware
Mechanical drawings
Pin signals
RSSI PWM
SIM card
The Associate LED

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

64
64
66
66
66

63

Hardware

Mechanical drawings

Mechanical drawings
The following figures show the mechanical drawings for the XBee Smart Modem. All dimensions are in
inches.

Pin signals
The pin locations are:

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

64

Hardware

Pin signals

The following table shows the pin assignments for the through-hole device. In the table, low-asserted
signals have a horizontal line above signal name.
Pin Name

Direction Default

Description

1

VCC

2

DOUT

Output

Output

UART Data Out

3

DIN / CONFIG

Input

Input

UART Data In

4

DIO12 / SPI_MISO

Either

Disabled Digital I/O 12 or SPI Slave Output line1

5

RESET

Input

6

PWM0 / RSSI /
DIO10/USB_VBUS

Either

Output

7

DIO11/USB D+

Either

Disabled Digital I/O 11 or USB Direct D+ line

8

USB D-

9

DTR / SLEEP_RQ/
DIO8

10

GND

11

DIO4 / SPI_MOSI

Either

Disabled Digital I/O 4 or SPI Slave Input Line

12

CTS / DIO7

Either

Output

Output Clear-to-Send Flow Control or Digital I/O 7

13

ON /SLEEP/DIO9

Output

Output

Module Status Indicator or Digital I/O 9

14

VREF

-

15

Associate / DIO5

Either

Output

16

RTS / DIO6

Either

Disabled Input Request-to-Send Flow Control, Digital I/O 6

17

AD3 / DIO3 / SPI_
SS

Either

Disabled Analog Input 3 or Digital I/O 3, SPI low enabled
select line

18

AD2 / DIO2 / SPI_
CLK

Either

Disabled Analog Input 2 or Digital I/O 2, SPI Clock line

19

AD1 / DIO1 / SPI_
ATTN

Either

Disabled Analog Input 1 or Digital I/O 1, SPI Attention line
output

20

AD0 / DIO0

Either

Input

Power supply

PWM Output 0 / RX Signal Strength Indicator /
Digital I/O 10

USB Direct D- line
Either

Disabled Pin Sleep Control Line or Digital I/O 8
Ground

Feature not supported on this device. Used on
other XBee devices for analog voltage reference.
Associated Indicator, Digital I/O 5

Analog Input 0, Digital I/O 0

Pin connection recommendations
To ensure compatibility with future updates, make USB D+ and D- (pin 7 and pin 8) available in your
design.

1DIO12/SPI_MISO and DIO4/SPI_MOSI (pin 4 and pin 11) may optionally be configured as a secondary UART

serial port using MicroPython. See the Digi MicroPython Programming Guide for details.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

65

Hardware

RSSI PWM

The recommended minimum pin connections are VCC, GND, DIN, DOUT, RTS, DTR and RESET.
Firmware updates require access to these pins.

RSSI PWM
The XBee Smart Modem features an RSSI/PWM pin (pin 6) that, if enabled, adjusts the PWM output to
indicate the signal strength of the cellular connection. Use P0 (DIO10/PWM0 Configuration) to enable
the RSSI pulse width modulation (PWM) output on the pin. If P0 is set to 1, the RSSI/PWM pin outputs a
PWM signal where the frequency is adjusted based on the received signal strength of the cellular
connection.
The RSSI/PWM output is enabled continuously unlike other XBee products where the output is enabled
for a short period of time after each received transmission. If running on the XBIB development board,
DIO10 is connected to the RSSI LEDs, which may be interpreted as follows:
Number of LEDs turned
PWM duty cycle on

Received signal strength (dBm)

79.39% or more

3

-83 dBm or higher

62.42% to
79.39%

2

-93 to -83 dBm

45.45% to
62.42%

1

-103 to -93 dBm

Less than
45.45%

0

Less than -103 dBm, or no cellular network
connection

SIM card
The XBee Smart Modem uses a 4FF (Nano) size SIM card.
CAUTION! Never insert or remove SIM card while the power is on!

The Associate LED
The following table describes the Associate LED functionality. For the location of the Associate LED on
the XBIB-U development board, see number 6 on the XBIB-U-DEV reference.

LED status

Blink
timing

On, solid
Double blink

Meaning
Not joined to a mobile network.

½ second The last TCP/UDP/SMS attempt failed. If the LED has this pattern,
you may need to check DI (Remote Manager Indicator) or CI
(Protocol/Connection Indication) for the cause of the error.

Standard single blink 1 second

Normal operation.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

66

Hardware

The Associate LED

The normal association LED signal alternates evenly between high and low as shown below:

Where the low signal means LED off and the high signal means LED on.
When CI is not 0 or 0xFF, the Associate LED has a different blink pattern that looks like this:

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

67

Antenna recommendations
Antenna connections
Keepout area
Antenna placement

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

69
70
71

68

Antenna recommendations

Antenna connections

Antenna connections
CAUTION! The XBee Smart Modem will not function properly with only the secondary
antenna port connected!

The XBee Smart Modem has two U.FL antenna ports; a primary on the upper left of the board and a
secondary port on the upper right, see the drawing below. You must connect the primary port and the
secondary port is optional. The secondary antenna improves receive performance in certain
situations, so we recommend it for best results.

See FCC-approved antennas for a list of approved antennas.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

69

Antenna recommendations

Keepout area

Connect the antenna cables as shown below.
WARNING! If you must run cables through the keepout area, keep them out of the left
area, and do not cover the embedded antennas.

Keepout area
The following drawing shows important recommendations for designing with the PCB antenna
module using an embedded antenna for Bluetooth. Do not mount the surface-mount PCB antenna
module on the RF Pad footprint because that footprint requires a ground plane within the keepout
area.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

70

Antenna recommendations

Antenna placement

Through-hole keepout

Notes
1. We recommend non-metal enclosures. For metal enclosures, use an external antenna.
2. Keep metal chassis or mounting structures in the keepout area at least 2.54 cm (1 in) from the
antenna.
3. Maximize the distance between the antenna and metal objects that might be mounted in the
keepout area.
4. These keepout area guidelines do not apply for wire whip antennas or external RF connectors.
Wire whip antennas radiate best over the center of a ground plane.

Antenna placement
For optimal cellular reception, keep the antenna as far away from metal objects and other electronics
(including the XBee Smart Modem) as possible. Often, small antennas are desirable, but come at the
cost of reduced range and efficiency.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

71

Design recommendations
Cellular component firmware updates
USB Direct design
Power supply considerations
Recommended application circuit
Heat considerations and testing
Heat sink guidelines
Add a fan to provide active cooling

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

73
73
73
74
74
75
76

72

Design recommendations

Cellular component firmware updates

Cellular component firmware updates
Even if you do not plan to use the USB interface (Pin 7 and 8), we strongly recommend you provide a
way to access the USB pins (Pin 7 and 8) to support direct firmware updates of the Cellular modem.
You should keep Pins 7 and 8 routing as a 90 ohm diff pair for USB communications.
CAUTION! If you do not provide access to these USB pins, you may be unable to perform
cellular component firmware updates.

One way to provide access to the USB interface is to connect the USB pins to a header or USB
connector on the host design; see USB Direct design for more information. At a minimum you should
connect pins 7 and 8 to test points so they are easy to wire to a connector if necessary.
If you are using the USB pins for other purposes you must provide a way to disconnect those
interfaces during USB operation, such as using zero ohm resistors.

USB Direct design
Connect USB data pins 7 and 8 (USB_D+ and USB_D- respectively) on the XBee Smart Modem to the
appropriate pins on the host processor or connector. You may optionally connect pin 6 to VBUS for
future compatibility, but the VBUS feature is not supported on this product. See USB direct mode for
more information on how USB is enabled and disabled.
The USB interface follows the USB 2.0 high speed specification and data lines must be designed as a
90 Ω differential pair. Both traces should be the same length and the overall trace length should be
kept as short as possible. If you are connecting to a USB connector then we recommend that you
employ an ESD suppressor appropriate for USB 2.0 HS (for example the Littelfuse PESD0402-140).
Other than the ESD suppressor, do not place additional components in the signal paths. The
suppressor is not needed if you are connecting to an on-board host processor.
CAUTION! If you use pins 7 and 8 for USB you must dedicate the pins to that interface.
Adding any traces to the main USB trace and/or connecting those traces to other
components will introduce signal integrity issues, which may result in unreliable USB
operation.

Power supply considerations
When considering a power supply, use the following design practices.
1. Power supply ripple should be less than 75 mV peak to peak.
2. The power supply should be capable of providing a minimum of 1.5 A at 3.3 V (5 W). Keep in
mind that operating at a lower voltage requires higher current capability from the power
supply to achieve the 5 W requirement.
3. Place sufficient bulk capacitance on the XBee VCC pin to maintain voltage above the minimum
specification during inrush current. Inrush current is about 2 A during initial power up of cellular
communications and wakeup from sleep mode.
4. Place smaller high frequency ceramic capacitors very close to the XBee Smart Modem VCC pin
to decrease high frequency noise.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

73

Design recommendations

Recommended application circuit

5. Use a wide power supply trace or power plane to ensure it can handle the peak current
requirements with minimal voltage drop. We recommend that the power supply and trace be
designed such that the voltage at the XBee VCC pin does not vary by more than 0.1 V between
light load (~0.5 W) and heavy load (~3 W).

Recommended application circuit
In high EMI noise environments, we recommend adding a 10 nF ceramic capacitor very close to pin 5.

Heat considerations and testing
The XBee Smart Modem may generate significant heat during sustained operation. In addition to
heavy data transfer, other factors that can contribute to heating include ambient temperature, air
flow around the device, and proximity to the nearest cellular tower (the XBee Smart Modem must
transmit at a higher power level when communicating over long distances). Overheating can cause
device malfunction and potential damage. In order to avoid this it is important to consider the
application the XBee Smart Modem is going into and mitigate heat issues if necessary. We recommend
that you perform thermal testing in your application to determine the resulting steady state
temperature of the XBee Smart Modem. Use TP (Temperature) to estimate the device temperature.
Convert the TP reading from hex format to decimal.
You also need to know the ambient temperature and the average current consumption during your
test. If you do not have a way to measure current consumption you can estimate it from the table in
the next section.
Use those results to approximate the maximum safe ambient temperature for the XBee Smart
Modem, TMAX,amb, with the following equation:

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

74

Design recommendations

Heat sink guidelines

Where:
TXBee is the steady state temperature of the XBee Smart Modem that you measured during your test
(if using the TP command, be sure to convert from hex format to decimal).
Tamb,test is the ambient air temperature during your test.
IAVG,test is the average current measured during your test.
IMAX is the average current draw expected for your application when transmitting at maximum RF
power; see Power consumption.

Heat sink guidelines
Based on the results of your thermal testing you may find it is advisable or required to implement a
method of dissipating excess heat. This section explains how to employ a heat sink on top of the XBee
Smart Modem.
A bolt-down style heat sink on top of the XBee Smart Modem provides the best performance. An
example part number is Advanced Thermal Solutions ATS-PCBT1084/ATS-PCB1084. You must use an
electrically non-conductive thermal gasket on top of the XBee device under the area that will be
covered by the heat sink. A thermal gasket such as Gap Pad® 2500S20 is suitable for this purpose. We
recommend using a gasket with thickness of at least 0.080 in to ensure that components on top of
the XBee device do not tear through the material when pressure is applied to the heat sink.
Install the SIM card prior to placement of the heat sink. Position the thermal gasket and heat sink
assembly on the top of the device so that it covers the entire section shown inside the blue box below
(covering the RF shield with thermal gasket is optional because the RF shield is allowed to directly
contact the heat sink). Do not cover the U.FL connectors.

When attaching to the host PCB, tighten the mounting hardware until the gasket is compressed at
least 25% and the heat sink is snug against the RF shield. Avoid overtightening. To prevent shorting,
check that the surface of the heat sink does not directly contact any of the XBee device components.
You may also use an adhesive style heat sink with the XBee Smart Modem, such as Wakefield-Vette
658-45ABT3. Follow the instructions above, except do not cover the area under the RF shield with
thermal gasket; connect this surface directly to the heat sink for mechanical strength. The thermal
gasket must be used on top of all other components under the heat sink to prevent shorting and
provide effective thermal transfer to the heat sink.
The following table provides a list of typical scenarios and the maximum ambient temperature at
which the XBee Smart Modem can be safely operated under that condition. These are provided only as
guidelines as your results will vary based on application. We recommend that you perform sufficient

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

75

Design recommendations

Add a fan to provide active cooling

testing, as explained in Heat considerations and testing, to ensure that the XBee Smart Modem does
not exceed temperature specifications.
Maximum safe
ambient
temperature
Heat
No
sink
heat Heat and
sink sink fan

Average current
consumption
(VCC = 3.3V)
Example application

Peak data
consumed
(MB/hr)

Maximum
transmission duty
cycle

950 mA

Running video camera

500 to
2000

N/A

40 C

60 C

50% duty cycle

475 mA

Running low resolution
video camera

200 to 400

42 C

65 C

75 C

20% duty cycle

200 mA

Sending high resolution 50 to 150
photo less than once per
minute

64 C

74 C

78 C

Device awake,
limited
transmissions

170 mA

Updating traffic sign

66 C

75 C

80 C

Device primarily
asleep, very
limited
transmissions

20 mA

Small data
Less than
transmission/receptions 0.1
which occur once per
hour

80 C

80 C

80 C

Scenario

1 to 10

Add a fan to provide active cooling
Another option for heat mitigation is to add a fan to your system to provide active cooling. You can use
a fan instead of or in addition to a heat sink. The XBee Smart Modem offers a fan control feature on
I/O pin DIO11 (pin 7). When the functionality is enabled, that line is pulled high to indicate when the fan
should be turned on. The line is pulled high when the device gets above 70 °C and the cellular
component is running, and turns off when the device drops below 65 °C.
To enable the functionality set P1 (DIO11/PWM1 Configuration) to 1. Note that the I/O pin is not
capable of driving a fan directly; you must implement a circuit to power the fan from a suitable power
source.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

76

Cellular connection process
Connecting
Data communication with remote servers (TCP/UDP)
Disconnecting
SMS encoding

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

78
78
78
79

77

Cellular connection process

Connecting

Connecting
In normal operations, the XBee Smart Modem automatically attempts both a cellular network
connection and a data network connection on power-up. The sequence of these connections is as
follows:

Cellular network
1. The device powers on.
2. It looks for cellular towers.
3. It chooses a candidate tower with the strongest signal.
4. It negotiates a connection.
5. It completes cellular registration; the phone number and SMS are available.

Data network connection
1. The network enables the evolved packet system (EPS) bearer with an access point name
(APN). See AN (Access Point Name) if you have APN issues. You can use OA (Operating APN) to
query the APN value currently configured in the cellular component.
2. The device negotiates a data connection with the access point.
3. The device receives its IP configuration and address.
4. The AI (Association Indication) command now returns a 0 and the sockets become available.

Data communication with remote servers (TCP/UDP)
Once the data network connection is established, communication with remote servers can be
initiated in several ways:
n Transparent mode data sent to the serial port (see TD (Text Delimiter) and RO (Packetization
Timeout) for timing).
n

API mode: Transmit (TX) Request: IPv4 - 0x20 received over the serial connection.

n

Digi Remote Manager connectivity begins.

Data communication begins when:
1. A socket opens to the remote server.
2. Data is sent.
Data connectivity ends when:
1. The server closes the connection.
2. The TM timeout expires (see TM (IP Client Connection Timeout)).
3. The cellular network may also close the connection after a timeout set by the network
operator.

Disconnecting
When the XBee Smart Modem is put into Airplane mode or deep sleep is requested:

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

78

Cellular connection process

SMS encoding

1. Sockets are closed, cleanly if possible.
2. The cellular connection is shut down.
3. The cellular component is powered off.
Note We recommend entering Airplane mode before resetting or rebooting the device to allow the
cellular module to detach from the network.

SMS encoding
The XBee Smart Modem transmits SMS messages using the standard GSM 03.38 character set.1
Because this character set only provides 7 bits of space per character, the XBee Smart Modem
ignores the most significant bit of each octet in an SMS transmission payload.
The device converts incoming SMS messages to ASCII. Characters that cannot be represented in
ASCII are replaced with a space (' ', or 0x20 in hex). This includes emoji and other special characters.

1Also referred to as the GSM 7-bit alphabet.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

79

Modes
Select an operating mode
Transparent operating mode
API operating mode
Bypass operating mode
USB direct mode
Command mode
MicroPython mode

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

81
82
82
82
83
83
86

80

Modes

Select an operating mode

Select an operating mode
The XBee Smart Modem interfaces to a host device such as a microcontroller or computer through a
logic-level asynchronous serial port. It uses a UART for serial communication with those devices.
The XBee Smart Modem supports three operating modes: Transparent operating mode, API operating
mode, and Bypass operating mode. The default mode is Transparent operating mode. Use the AP (API
Enable) command to select a different operating mode.
The following flowchart illustrates how the modes relate to each other.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

81

Modes

Transparent operating mode

Transparent operating mode
Devices operate in this mode by default. The device acts as a serial line replacement when it is in
Transparent operating mode. The device queues all serial data it receives through the DIN pin for RF
transmission. When a device receives RF data, it sends the data out through the DOUT pin. You can set
the configuration parameters using Command mode.
The IP (IP Protocol) command setting controls how Transparent operating mode works for the XBee
Smart Modem.
Note Transparent operation is not available when using SPI.

API operating mode
API operating mode is an alternative to Transparent operating mode. API mode is a frame-based
protocol that allows you to direct data on a packet basis. The device communicates UART or SPI data
in packets, also known as API frames. This mode allows for structured communications with
computers and microcontrollers.
The advantages of API operating mode include:
n It is easier to send information to multiple destinations
n

The host receives the source address for each received data frame

n

You can change parameters without entering Command mode

Bypass operating mode
CAUTION! Bypass operating mode is an alternative to Transparent and API modes for
advanced users with special configuration needs. Changes made in this mode might
change or disable the device and we do not recommended it for most users.

In Bypass mode, the device acts as a serial line replacement to the cellular component. In this mode,
the XBee Smart Modem exposes all control of the cellular component's AT port through the UART. If
you use this mode, you must setup the cellular modem directly to establish connectivity. The modem
does not automatically connect to the network.
Note The cellular component can become unresponsive in Bypass mode. See Unresponsive cellular
component in Bypass mode for help in this situation.
When Bypass mode is active, most of the XBee Smart Modem's AT commands do not work. For
example, IM (IMEI) may never return a value, and DB does not update. In this configuration, the
firmware does not test communication with the cellular component (which it does by sending AT
commands). This is useful in case you have reconfigured the cellular component in a way that makes it
incompatible with the firmware. Bypass operating mode exists for users who wish to communicate
directly with the cellular component settings and do not intend to use XBee Smart Modem software
features such as API mode.
Command mode is available while in Bypass mode; see Enter Command mode for instructions.

Enter Bypass operating mode
To configure a device for Bypass operating mode:

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

82

Modes

USB direct mode

1. Set the AP (API Enable) parameter value to 5.
2. Send WR (Write) to write the changes.
3. Send FR (Force Reset) to reboot the device.
4. After rebooting, enter Command mode and verify that Bypass operating mode is active by
querying AI (Association Indication) and confirming that it returns a value of 0x2F.
It may take a moment for Bypass operating mode to become active.

Leave Bypass operating mode
To configure a device to leave Bypass operating mode:
1. Set AP (API Enable) to something other than 5.
2. Send WR (Write) to write the changes.
3. Send FR (Force Reset) to reboot the device.
4. After rebooting, enter Command mode and verify that Bypass operating mode is not active by
querying AI (Association Indication) and confirming that it returns a value other than 0x2F.

Restore cellular settings to default in Bypass operating mode
Send AT&F1 to reset the cellular component to its factory profile.

USB direct mode
This mode allows you to replace the cellular component with the XBee Smart Modem such that the
USB lines are the same through a configuration option.

Enable USB direct mode
Set P1 (DIO11/PWM1 Configuration) to 7 to enable USB direct mode. When set to 7 DIO11/PWM1 (pin
7) brings out the USB D+ signal of the cellular component. The USB D- signal is available on pin 8. With
these pins connected to a USB host a direct connection is made to the cellular component which is not
mediated by the XBee processor.
When in USB direct mode AI (Association Indication) returns 0x2B.

Command mode
Command mode is a state in which the firmware interprets incoming characters as commands. It
allows you to modify the device’s configuration using parameters you can set using AT
commands. When you want to read or set any parameter of the XBee Smart Modem using this mode,
you have to send an AT command. Every AT command starts with the letters AT followed by the two
characters that identify the command and then by some optional configuration values.
The operating modes of the XBee Smart Modem are controlled by the AP (API Enable) setting,
but Command mode is always available as a mode the device can enter while configured for any of the
operating modes.
Command mode is available on the UART interface for all operating modes. You cannot use the SPI
interface to enter Command mode.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

83

Modes

Command mode

Enter Command mode
To get a device to switch into Command mode, you must issue the following sequence: +++ within one
second. There must be at least one second preceding and following the +++ sequence. Both the
command character (CC) and the silence before and after the sequence (GT) are configurable. When
the entrance criteria are met the device responds with OK\r on UART signifying that it has entered
Command mode successfully and is ready to start processing AT commands.
If configured to operate in Transparent operating mode, when entering Command mode the XBee
Smart Modem knows to stop sending data and start accepting commands locally.
Note Do not press Return or Enter after typing +++ because it interrupts the guard time silence and
prevents you from entering Command mode.
When the device is in Command mode, it listens for user input and is able to receive AT commands on
the UART. If CT time (default is 10 seconds) passes without any user input, the device drops out of
Command mode and returns to the previous operating mode. You can force the device to leave
Command mode by sending CN (Exit Command mode).
You can customize the command character, the guard times and the timeout in the device’s
configuration settings. For more information, see CC (Command Sequence Character), CT (Command
Mode Timeout) and GT (Guard Times).

Troubleshooting
Failure to enter Command mode is often due to baud rate mismatch. Ensure that the baud rate of the
connection matches the baud rate of the device. By default, BD (Baud Rate) = 3 (9600 b/s).
There are two alternative ways to enter Command mode:
n A serial break for six seconds enters Command mode. You can issue the "break" command
from a serial console, it is often a button or menu item.
n

Asserting DIN (serial break) upon power up or reset enters Command mode. XCTU guides you
through a reset and automatically issues the break when needed.

Both of these methods temporarily set the device's baud rate to 9600 and return an OK on the UART
to indicate that Command mode is active. When Command mode exits, the device returns to normal
operation at the baud rate that BD is set to.

Send AT commands
Once the device enters Command mode, use the syntax in the following figure to send AT commands.
Every AT command starts with the letters AT, which stands for "attention." The AT is followed by two
characters that indicate which command is being issued, then by some optional configuration values.
To read a parameter value stored in the device’s register, omit the parameter field.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

84

Modes

Command mode

Multiple AT commands
You can send multiple AT commands at a time when they are separated by a comma in Command
mode; for example, ATNIMy XBee,AC.
The preceding example changes the NI (Node Identifier) to My XBee and makes the setting active
through AC (Apply Changes).

Parameter format
Refer to the list of AT commands for the format of individual AT command parameters. Valid formats
for hexidecimal values include with or without a leading 0x for example FFFF or 0xFFFF.

Response to AT commands
When using AT commands to set parameters the XBee Smart Modem responds with OK if
successful and ERROR if not.
For devices with a file system:
ATAP1
OK
When reading parameters, the device returns the current parameter value instead of an OK message.
ATAP
1

Apply command changes
Any changes you make to the configuration command registers using AT commands do not take effect
until you apply the changes. For example, if you send the BD command to change the baud rate, the
actual baud rate does not change until you apply the changes. To apply changes:
1. Send AC (Apply Changes).
2. Send WR (Write).
or:
3. Exit Command mode.

Make command changes permanent
Send a WR (Write) command to save the changes. WR writes parameter values to non-volatile memory
so that parameter modifications persist through subsequent resets.
Send as RE command to wipe settings saved using WR back to their factory defaults.
Note You still have to use WR to save the changes enacted with RE.

Exit Command mode
1. Send CN (Exit Command mode) followed by a carriage return.
or:
2. If the device does not receive any valid AT commands within the time specified by CT
(Command Mode Timeout), it returns to Transparent or API mode. The default Command mode
timeout is 10 seconds.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

85

Modes

MicroPython mode
For an example of programming the device using AT Commands and descriptions of each configurable
parameter, see AT commands.

MicroPython mode
MicroPython mode (AP = 4) allows you to communicate with the XBee Smart Modem using the
MicroPython programming language. You can use the MicroPython Terminal tool in XCTU to
communicate with the MicroPython stack of the XBee Smart Modem through the serial interface.
MicroPython mode connects the primary serial port to the stdin/stdout interface on MicroPython,
which is either the REPL or code launched at startup.
When code runs in MicroPython with AP set to a value other than 4, stdout goes to the bit bucket and
there is no input to read on stdin.

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

86

Sleep modes
About sleep modes
Normal mode
Pin sleep mode
Cyclic sleep mode
Cyclic sleep with pin wake up mode
Connected sleep mode
The sleep timer
MicroPython sleep behavior

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

88
88
88
88
88
88
89
89

87

Sleep modes

About sleep modes

About sleep modes
A number of low-power modes exist to enable devices to operate for extended periods of time on
battery power. Use SM (Sleep Mode) to enable these sleep modes.

Normal mode
Set SM to 0 to enter Normal mode.
Normal mode is the default sleep mode. If a device is in this mode, it does not sleep and is always
awake.
Devices in Normal mode are typically mains powered.

Pin sleep mode
Set SM to 1 to enter pin sleep mode.
Pin sleep allows the device to sleep and wake according to the state of the SLEEP_RQ pin (SLEEP_RQ).
When you assert SLEEP_RQ (high), the device finishes any transmit or receive operations, closes any
active connection, and enters a low-power state.
When you de-assert SLEEP_RQ (low), the device wakes from pin sleep.

Cyclic sleep mode
Set SM to 4 to enter Cyclic sleep mode.
Cyclic sleep allows the device to sleep for a specific time and wake for a short time to poll.
If you use the D7 command to enable hardware flow control, the CTS pin asserts (low) when the
device wakes and can receive serial data, and de-asserts (high) when the device sleeps.

Cyclic sleep with pin wake up mode
Set SM to 5 to enter Cyclic sleep with pin wake up mode.
This mode is a slight variation on Cyclic sleep mode (SM = 4) that allows you to wake a device
prematurely by de-asserting the SLEEP_RQ pin (SLEEP_RQ).
In this mode, you can wake the device after the sleep period expires, or if a high-to-low transition
occurs on the SLEEP_RQ pin.

Connected sleep mode
XBee Smart Modem hardware part number XB3-C-A1-UT-xxx can enter Connected sleep mode.
Set bit 0 of SO (Sleep Options) for connected sleep. When bit 0 is set and the XBee Smart Modem goes
to sleep, instead of the cellular component shutting down, it enters a lower power consumption mode
that maintains registration with the cellular network. This allows significantly faster resumption of
communications when coming out of sleep at the cost of additional power used.
Connected sleep mode draws 9 mA during sleep and 11 mA average over time (including periodically
waking up to maintain connection).

Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

88

Sleep modes

The sleep timer

The sleep timer
The sleep timer starts when the device wakes and resets on re-configuration. When the sleep timer
expires the device returns to sleep.

MicroPython sleep behavior
When the XBee Smart Modem enters Deep Sleep mode, any MicroPython code currently executing is
suspended until the device comes out of sleep. When the XBee Smart Modem comes out of sleep
mode, MicroPython execution continues where it left off.
Upon entering deep sleep mode, the XBee Smart Modem closes any active UDP connections and turns
off the cellular component. As a result, any sockets that were opened in MicroPython prior to sleep
report as no longer being connected. This behavior appears the same as a typical socket
disconnection event will:
n socket.send raises OSError: ENOTCONN
n

socket.sendto raises OSError: ENOTCONN

n

socket.recv returns the empty string, the traditional end-of-file return value

n

socket.recvfrom returns an empty message, for example:
(b'', (
, ) ) The underlying UDP socket resources have been released at this point. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 89 Power saving features Airplane mode Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 91 90 Power saving features Airplane mode Airplane mode While not technically a sleep mode, Airplane mode is another way of saving power. When set, the cellular component of the XBee Smart Modem is fully turned off and no access to the cellular network is performed or possible. Use AM (Airplane Mode) to configure this mode. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 91 Serial communication Serial interface Serial data UART data flow Serial buffers CTS flow control RTS flow control Enable UART or SPI ports Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 93 93 93 93 94 94 94 92 Serial communication Serial interface Serial interface The XBee Smart Modem interfaces to a host device through a serial port. The device's serial port can communicate: n Through a logic and voltage compatible universal asynchronous receiver/transmitter (UART). n Through a level translator to any serial device, for example, through an RS-232 or USB interface board. n Through a serial peripheral interface (SPI) port. Serial data A device sends data to the XBee Smart Modem's UART through pin 3 DIN as an asynchronous serial signal. When the device is not transmitting data, the signals should idle high. For serial communication to occur, you must configure the UART of both devices (the microcontroller and the XBee Smart Modem) with compatible settings for the baud rate, parity, start bits, stop bits, and data bits. Each data byte consists of a start bit (low), 8 data bits (least significant bit first) and a stop bit (high). The following diagram illustrates the serial bit pattern of data passing through the device. The diagram shows UART data packet 0x1F (decimal number 31) as transmitted through the device. You can configure the UART baud rate, parity, and stop bits settings on the device with the BD, NB, and SB commands respectively. For more information, see Serial interfacing commands. In the rare case that a device has been configured with the UART disabled, you can recover the device to UART operation by holding DIN low at reset time. DIN forces a default configuration on the UART at 9600 baud and it brings the device up in Command mode on the UART port. You can then send the appropriate commands to the device to configure it for UART operation. If those parameters are written, the device comes up with the UART enabled on the next reset. UART data flow Devices that have a UART interface connect directly to the pins of the XBee Smart Modem as shown in the following figure. The figure shows system data flow in a UART-interfaced environment. Lowasserted signals have a horizontal line over the signal name. Serial buffers The XBee Smart Modem maintains internal buffers to collect serial and RF data that it receives. The serial receive buffer collects incoming serial characters and holds them until the device can process them. The serial transmit buffer collects the data it receives via the RF link until it transmits that data out the serial or SPI port. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 93 Serial communication CTS flow control CTS flow control We strongly encourage you to use flow control with the XBee Smart Modem to prevent buffer overruns. CTS flow control is enabled by default; you can disable it with D7 (DIO7/CTS). When the serial receive buffer fills with the number of bytes specified by FT (Flow Control Threshold), the device de-asserts CTS (sets it high) to signal the host device to stop sending serial data. The device re-asserts CTS when less than FT-32 bytes are in the UART receive buffer. Note Serial flow control is not possible when using the SPI port. RTS flow control If you set D6 (DIO6/RTS) to enable RTS flow control, the device does not send data in the serial transmit buffer out the DOUT pin as long as RTS is de-asserted (set high). Do not de-assert RTS for long periods of time or the serial transmit buffer will fill. Enable UART or SPI ports To enable the UART port, configure DIN and DOUT (P3 and P4 parameters) as peripherals. To enable the SPI port, enable SPI_MISO, SPI_MOSI, SPI_SSEL , and SPI_CLK (P5 through P9) as peripherals. If you enable both ports then output goes to the UART until the first input on SPI. When both the UART and SPI ports are enabled on power-up, all serial data goes out the UART. As soon as input occurs on either port, that port is selected as the active port and no input or output is allowed on the other port until the next device reset. If you change the configuration so that only one port is configured, then that port is the only one enabled or used. If the parameters are written with only one port enabled, then the port that is not enabled is not used even temporarily after the next reset. If both ports are disabled on reset, the device uses the UART in spite of the wrong configuration so that at least one serial port is operational. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 94 SPI operation SPI communications Full duplex operation Low power operation Select the SPI port Force UART operation Data format Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 96 97 98 98 99 99 95 SPI operation SPI communications SPI communications The XBee Smart Modem supports SPI communications in slave mode. Slave mode receives the clock signal and data from the master and returns data to the master. The following table shows the signals that the SPI port uses on the device. Signal Function SPI_MOSI Inputs serial data from the master (Master Out, Slave In) SPI_MISO (Master In, Slave Out) Outputs serial data to the master SPI_SCLK (Serial Clock) Clocks data transfers on MOSI and MISO SPI_SSEL (Slave Select) Enables serial communication with the slave SPI_ATTN (Attention) Alerts the master that slave has data queued to send. The XBee Smart Modem asserts this pin as soon as data is available to send to the SPI master and it remains asserted until the SPI master has clocked out all available data. In this mode: n SPI clock rates up to 4.8 MHz are possible. n Data is most significant bit (MSB) first; bit 7 is the first bit of a byte sent over the interface. n Frame Format mode 0 is used. This means CPOL= 0 (idle clock is low) and CPHA = 0 (data is sampled on the clock’s leading edge). n The SPI port only supports API Mode (AP = 1). The following diagram shows the frame format mode 0 for SPI communications. SPI mode is chip to chip communication. We do not supply a SPI communication option on the device development evaluation boards. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 96 SPI operation Full duplex operation Full duplex operation The specification for SPI includes the four signals SPI_MISO, SPI_MOSI, SPI_CLK, and SPI_SSEL. Using these four signals, the SPI master cannot know when the slave needs to send and the SPI slave cannot transmit unless enabled by the master. For this reason, the SPI_ATTN signal is available in the design. This allows the SPI slave to alert the SPI master that it has data to send. In turn, the SPI master is expected to assert SPI_SSEL and start SPI_CLK, unless these signals are already asserted and active respectively. This, in turn, allows the XBee Smart Modem SPI slave to send data to the master. SPI data is latched by the master and slave using the SPI_CLK signal. When data is being transferred the MISO and MOSI signals change between each clock. If data is not available then these signals will not change and will be either 0 or 1. This results in receiving either a repetitive 0 or 0xFF. The means of determining whether or not received data is valid is by packetizing the data with API packets, without escaping. Valid data to and from the XBee Smart Modem is delimited by 0x7E, a length, the payload, and finally a checksum byte. Everything else in both directions should be ignored. The bytes received between frames will be either 0xff or 0x00. This allows the SPI master to scan for a 0x7E delimiter between frames. SPI allows for valid data from the slave to begin before, at the same time, or after valid data begins from the master. When the master is sending data to the slave and the slave has valid data to send in the middle of receiving data from the master, it allows a true full duplex operation where data is valid in both directions for a period of time. During this time, the master and slave must simultaneously transmit valid data at the clock speed so that no invalid bytes appear within an API frame, causing the whole frame to be discarded. An example follows to more fully illustrate the SPI interface during the time valid data is being sent in both directions. First, the master asserts SPI_SSEL and starts SPI_CLK to send a frame to the slave. Initially, the slave does not have valid data to send the master. However, while it is still receiving data from the master, it has its own data to send. Therefore, it asserts SPI_ATTN low. Seeing that SPI_ SSEL is already asserted and that SPI_CLK is active, it immediately begins sending valid data, even while it is receiving valid data from the master. In this example, the master finishes its valid data before the slave does. The master will have two indications of valid data: The SPI_ATTN line is asserted and the API frame length is not yet expired. For both of these reasons, the master should keep SPI_SSEL asserted and should keep SPI_CLK toggling in order to receive the end of the frame from the slave, even though these signals were originally turned on by the master to send data. During the time that the SPI master is sending invalid data to the SPI slave, it is important no 0x7E is included in that invalid data because that would trigger the SPI slave to start receiving another valid frame. The following figure illustrates the SPI interface while valid data is being sent in both directions. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 97 SPI operation Low power operation Low power operation Sleep modes generally work the same on SPI as they do on UART. However, due to the addition of SPI mode, there is an option of another sleep pin, as described below. By default, Digi configures DIO8 (SLEEP_REQUEST) as a peripheral and during pin sleep it wakes the device and puts it to sleep. This applies to both the UART and SPI serial interfaces. If SLEEP_REQUEST is not configured as a peripheral and SPI_SSEL is configured as a peripheral, then pin sleep is controlled by SPI_SSEL rather than by SLEEP_REQUEST. Asserting SPI_SSEL (pin 17) by driving it low either wakes the device or keeps it awake. Negating SPI_SSEL by driving it high puts the device to sleep. Using SPI_SSEL to control sleep and to indicate that the SPI master has selected a particular slave device has the advantage of requiring one less physical pin connection to implement pin sleep on SPI. It has the disadvantage of putting the device to sleep whenever the SPI master negates SPI_SSEL (meaning time is lost waiting for the device to wake), even if that was not the intent. If the user has full control of SPI_SSEL so that it can control pin sleep, whether or not data needs to be transmitted, then sharing the pin may be a good option in order to make the SLEEP_REQUEST pin available for another purpose. If the device is one of multiple slaves on the SPI, then the device sleeps while the SPI master talks to the other slave, but this is acceptable in most cases. If you do not configure either pin as a peripheral, then the device stays awake, being unable to sleep in SM1 mode. Select the SPI port n D1 (This parameter will only be changed if it is at a default of zero when the method is invoked.) n D2 n D3 n D4 n P2 As long as the host does not issue a WR command, these configuration values revert to previous values after a power-on reset. If the host issues a WR command while in SPI mode, these same parameters are written to flash. After a reset, parameters that were forced and then written to flash become the mode of operation. If the UART is disabled and the SPI is enabled in the written configuration, then the device comes up in SPI mode without forcing it by holding DOUT low. If both the UART and the SPI are enabled at the time of reset, then output goes to the UART until the host sends the first input. If that first input comes on the SPI port, then all subsequent output goes to the SPI port and the UART is disabled. If the first input comes on the UART, then all subsequent output goes to the UART and the SPI is disabled. When the master asserts the slave select (SPI_SSEL) signal, SPI transmit data is driven to the output pin SPI_MISO, and SPI data is received from the input pin SPI_MOSI. The SPI_SSEL pin has to be asserted to enable the transmit serializer to drive data to the output signal SPI_MISO. A rising edge on SPI_SSEL causes the SPI_MISO line to be tri-stated such that another slave device can drive it, if so desired. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 98 SPI operation Force UART operation Force UART operation If you configure a device with only the SPI enabled and no SPI master is available to access the SPI slave port, you can recover the device to UART operation by holding DIN / CONFIG low at reset time. DIN/CONFIG forces a default configuration on the UART at 9600 baud and brings up the device in Command mode on the UART port. You can then send the appropriate commands to the device to configure it for UART operation. If you write those parameters, the device comes up with the UART enabled on the next reset. Data format SPI only operates in API mode 1. The XBee Smart Modem does not support Transparent mode or API mode 2 (which escapes control characters). This means that the AP configuration only applies to the UART, and the device ignores it while using SPI. The reason for this operation choice is that SPI is full duplex. If data flows in one direction, it flows in the other. Since it is not always possible to have valid data flowing in both directions at the same time, the receiver must have a way to parse out the valid data and to ignore the invalid data. The XBee Smart Modem sends 0XFF when there is no data to send to the host. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 99 File system For detailed information about using MicroPython on the XBee Smart Modem refer to the Digi MicroPython Programming Guide. Overview of the file system XCTU interface Encrypt files Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 101 102 102 100 File system Overview of the file system Overview of the file system XBee Smart Modem firmware versions ending in 0B (for example, 1130B, 100B, 3100B) and later include support for storing files on an internal 1 MB SPI flash. CAUTION! You need to format the file system if upgrading a device that originally shipped with older firmware. You can use XCTU, AT commands or MicroPython for that initial format or to erase existing content at any time. Note To use XCTU with file system, you need XCTU 6.4.0 or newer. See ATFS FORMAT confirm and ensure that the format is complete. Directory structure The SPI flash appears in the file system as /flash, the only entry at the root level of the file system. It has a lib directory intended for MicroPython modules and a cert directory for files used for SSL/TLS sockets. Paths The XBee Smart Modem stores all of its files in the top-level directory /flash. On startup, the ATFS commands and MicroPython each use that as their current working directory. When specifying the path to a file or directory, it is interpreted as follows: n Paths starting with a forward slash are "absolute" and must start with /flash to be valid. n All other paths are relative to the current working directory. n The directory .. refers to the parent directory, so an operation on ../filename.txt that takes place in the directory /flash/test accesses the file /flash/filename.txt. n The directory . refers to the current directory, so the command ATFS ls . lists files in the current directory. n Names are case-insensitive, so FILE.TXT, file.txt and FiLe.TxT all refer to the same file. n File and directory names are limited to 64 characters, and can only contain letters, numbers, periods, dashes and underscores. A period at the end of the name is ignored. n The full, absolute path to a file or directory is limited to 255 characters. Secure files The file system includes support for secure files with the following properties: n Created via the ATFS XPUT command or in MicroPython using a mode of * with the open() method. n Unable to download via the ATFS GET command or MicroPython's open() method. n SHA256 hash of file contents available from ATFS HASH command (to compare with a local copy of a file). n Encrypted on the SPI flash. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 101 File system XCTU interface n MicroPython can execute code in secure files. n Sockets can use secure files when creating SSL/TLS connections. XCTU interface XCTU releases starting with 6.4.0 include a File System Manager in the Tools menu. You can upload files to and download files from the device, in addition to renaming and deleting existing files and directories. See the File System manager tool section of the XCTU User Guide for details of its functionality. Encrypt files You can encrypt files on the file system. This provides two things: 1. Protection of the client private key for SSL authentication while it is stored on the XBee Smart Modem. 2. Protection for user's MicroPython applications. Use ATFS XPUT filename to place encrypted files on the file system. The XPUT operation is otherwise identical to the PUT operation. Files placed in this way are indicated with a pound sign (#) following the filename. The XBee Smart Modem does not allow an encrypted file to be read by normal use so it: 1. Cannot be retrieved with the GET operation. 2. Cannot be opened and read in MicroPython applications. 3. Cannot be created by a MicroPython application. When ATFS HASH filename is run with the filename of an encrypted file, it reports the SHA256 hash of the file contents. In this way you can validate that the correct file has been placed on the XBee Smart Modem. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 102 Socket behavior Supported sockets Socket timeouts Socket limits in API mode Enable incoming TCP connections API mode behavior for outgoing TCP and SSL connections API mode behavior for outgoing UDP data API mode behavior for incoming TCP connections API mode behavior for incoming UDP data Transparent mode behavior for outgoing TCP and SSL connections Transparent mode behavior for outgoing UDP data Transparent mode behavior for incoming TCP connections Transparent mode behavior for incoming UDP connections Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 104 104 104 104 105 105 105 106 106 107 107 107 103 Socket behavior Supported sockets Supported sockets The XBee Smart Modem supports the following number of sockets: n 10 maximum: some combination of 6 TCP, 6 UDP, 6 SSL.1 Socket timeouts The XBee Smart Modem implicitly opens the socket any time there is data to be sent, and closes it according to the timeout settings. The TM (IP Client Connection Timeout) command controls the timeout settings. Socket limits in API mode There are a fixed number of sockets that can be created which varies by device variant and protocol. When a Transmit (TX) Request: IPv4 - 0x20 frame is sent to the XBee Smart Modem for a new destination, it creates a new socket. The exception to this is when using the UDP protocol with the C0 source port, which allows unlimited destinations on the socket created by C0 (Source Port). If no more sockets are available, the device sends back a Transmit (TX) Status - 0x89 frame with a Resource Error. The Resource Error resolves when an existing socket is closed. An existing socket may be closed when the socket times out (see TM (IP Client Connection Timeout) and TS (IP Server Connection Timeout)) or when the socket is closed via a TX request with the CLOSE flag set. Enable incoming TCP connections TCP establishes virtual connections between the XBee Smart Modem and other devices. You can enable the XBee Smart Modem to listen for incoming TCP connections. Listen means waiting for a connection request from any remote TCP and port.2 The following devices support incoming TCP connections: n Part number: XBC-V1-UT-001 (Digi XBee Cellular Verizon LTE Cat 1) n Part number: XBC-M1-UT-001 (Digi XBee Cellular AT&T LTE Cat 1) n Part number: XB3-C-A1-UT-xxx (Digi XBee3 Cellular AT&T LTE Cat 1) The XBee Smart Modem only supports incoming TCP and UDP connections as configured in IP (IP Protocol), SSL is not supported. To enable incoming connections in XCTU: 1. Set AP (API Enable) to Transparent Mode [0] or API Mode. You can use either API mode with escapes or without escapes. 2. Set IP to TCP [1] or UDP [0]. 3. Set C0 (Source Port) to the value of the TCP port that the device listens on. 4. Click the Write button . 11 UDP socket is always reserved for DNS, so subtract 1 socket from the values above. 2See https://tools.ietf.org/html/rfc793. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 104 Socket behavior API mode behavior for outgoing TCP and SSL connections API mode behavior for outgoing TCP and SSL connections To initiate an outgoing TCP or SSL connection to a remote host, send a Transmit (TX) Request: IPv4 0x20 frame to the XBee Smart Modem's serial port specifying the destination address and destination port for the remote host; the data is optional and the source port is 0. If the connection is disconnected at any time, send a Transmit TX Request frame to trigger a new connection attempt. To send data over this connection use the Transmit (TX) Request: IPv4 - 0x20. The device sends a Transmit (TX) Status - 0x89 frame in reply to the Transmit TX Request indicating the status of the request. A status of 0 indicates the connection and/or data was successful and a non-zero value indicates a failure. Any data received on the connection is sent out the XBee Smart Modem's serial port as a Receive RX frame. A connection is closed when: n The remote end closes the connection. n No data is sent or received for longer than the socket timeout set by TM (IP Client Connection Timeout). n A Transmit TX Request is sent with the CLOSE flag set. API mode behavior for outgoing UDP data To send a UDP datagram to a remote host, send a Transmit (TX) Request: IPv4 - 0x20 frame to the XBee Smart Modem's serial port specifying the destination address and destination port of the remote host. If you use a source port of 0, the device creates a new socket for the purpose of sending to the remote host. The XBee Smart Modem supports a finite number of sockets, so if you need to send to many destinations: 1. The socket must be closed after use. or 2. You must use the socket specified by the C0 (Source Port) setting. To use the socket specified by the C0 setting, in the Transmit TX request frame use a source port that matches the value configured for the C0 setting. The device sends a Transmit (TX) Status - 0x89 frame in reply to the Transmit TX Request to indicate the status of the request. A status of 0 indicates the data was successfully sent out of the device and a non-zero value indicates a failure. Any data received on the UDP socket is sent out the XBee Smart Modem's serial port as a Receive (RX) Packet: IPv4 - 0xB0 frame. A UDP socket is closed when: n No data has been sent or received for longer than the socket timeout set by TM (IP Client Connection Timeout). n A transmit TX Request is sent with the CLOSE flag set. API mode behavior for incoming TCP connections For incoming connections and data in API mode, the XBee Smart Modem uses the C0 (Source Port) and IP (IP Protocol) settings to specify the listening port and protocol used. The XBee Smart Modem does not currently support the SSL protocol for incoming connections. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 105 Socket behavior API mode behavior for incoming UDP data When the IP setting is TCP the XBee Smart Modem allows multiple incoming TCP connections on the port specified by the C0 setting. Any data received on the connection is sent out the XBee Smart Modem's serial port as a Receive (RX) Packet: IPv4 - 0xB0 frame. To send data from the device over the connection, use the Transmit (TX) Request: IPv4 - 0x20 frame with the corresponding address fields received from the Receive RX frame. In other words: n Take the source address, source port, and destination port fields from the Receive (RX) frame and use those respectively as: n The destination address, destination port, and source port fields for the Transmit (TX) Request frame. A connection is closed when: n The remote end closes the connection. n No data has been sent or received for longer than the socket timeout set by TS (IP Server Connection Timeout). n A Transmit (TX) Request frame is sent with the CLOSE flag set. API mode behavior for incoming UDP data When the IP (IP Protocol) setting is UDP, any data sent from a remote host to the XBee Smart Modem's network port specified by the C0 (Source Port) setting is sent out the XBee Smart Modem's serial port as a Receive (RX) Packet: IPv4 - 0xB0 frame. To send data from the XBee Smart Modem to the remote destination, use the Transmit (TX) Request: IPv4 - 0x20 frame with the corresponding address fields received from the Receive RX frame. In other words take the source address, source port, and destination port fields from the Receive (RX) frame and use those respectively as the destination address, destination port, and source port fields for the Transmit (TX) Request frame. Transparent mode behavior for outgoing TCP and SSL connections For Transparent mode, the IP (IP Protocol) setting specifies the protocol and the DL (Destination Address) and DE (Destination Port) settings specify the destination address used for outgoing data (UDP) and outgoing connections (TCP and SSL). To initiate an outgoing TCP or SSL connection to a remote host, send data to the XBee Smart Modem's serial port. If CI (Protocol/Connection Indication) reports a value of 0, then the connection was successfully established, otherwise the value of CI indicates why the connection attempt failed. Any data received over the connection is sent out the XBee Smart Modem's serial port. A connection is closed when: n The remote end closes the connection. n No data has been sent or received for longer than the socket timeout set by TM (IP Client Connection Timeout). n You make and apply a change to the IP, DL, or DE. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 106 Socket behavior Transparent mode behavior for outgoing UDP data Transparent mode behavior for outgoing UDP data To send outgoing UDP data to a remote host, send data to the XBee Smart Modem's serial port. If CI (Protocol/Connection Indication) reports a value of 0, the data was successfully sent; otherwise, the value of CI indicates why the data failed to be sent. The RO (Packetization Timeout) setting provides some control in how the serial data gets packetized before being sent to the remote host. The first send opens up a UDP socket used to send and receive data. Any data received by this socket is sent out the XBee Smart Modem's serial port. Note Set RO to FF for realtime typing by humans. Also, see TD (Text Delimiter). Transparent mode behavior for incoming TCP connections The C0 (Source Port) and IP (IP Protocol) settings specify the listening port and protocol used for incoming connections (TCP) and incoming data (UDP) in Transparent mode. SSL is not currently supported for incoming connections. When the IP setting is TCP and there is no existing connection to or from the XBee Smart Modem, the device accepts one incoming connection. Any data received on the connection is sent out the XBee Smart Modem's serial port. Any data sent to the XBee Smart Modem's serial port is sent over the connection. If the connection is disconnected, it discards pending data. Transparent mode behavior for incoming UDP connections When the IP (IP Protocol) setting is UDP any data sent from a remote host to the XBee Smart Modem's network port specified by C0 (Source Port) is sent out the XBee Smart Modem's serial port. Any data sent to the XBee Smart Modem's serial port is sent to the network destination specified by the DL (Destination Address) and DE (Destination Port) settings. If the DL and DE settings are unspecified or invalid, the XBee Smart Modem discards data sent to the serial port. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 107 Transport Layer Security (TLS) For detailed information about using MicroPython on the XBee Smart Modem refer to the Digi MicroPython Programming Guide. TLS AT commands Transparent mode and TLS API mode and TLS Key formats Certificate formats Certificate limitations Cipher suites Server Name Indication (SNI) Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 109 110 110 110 110 110 110 111 108 Transport Layer Security (TLS) TLS AT commands TLS AT commands The AT commands ATFS (File System), TL (SSL/TLS Protocol Version), IP (IP Protocol), $0 (SSL/TLS Profile 0), $1 (SSL/TLS Profile 1), and $2 (SSL/TLS Profile 2) support TLS. The format of the $ commands is: AT$[];[];[] Where: n num: Profile index. Index zero is used for Transparent mode connections and TLS connections using Transmit (TX) Request: IPv4 - 0x20. n ca_cert: (optional) Filename of a file in the certs/ directory. Indicates the certificate identifying a trusted root certificate authority (CA) to use in validating servers. If ca_cert is empty the server certificate is notauthenticated. This must be a single root CA certificate. The modules do not allow a non-self signed certificate to work, so intermediate CAs are not enough. n client_cert: (optional) Filename of a file in the certs/ directory. Indicates the certificate presented to servers when requested for client authentication. If client_cert is empty no certificate is presented to the server should it request one. This may result in mutual authentication failure. n client_key: (optional) Filename of a file in the certs/ directory. Indicates the private key matching the public key contained in client_cert. This should be a secure file uploaded with ATFS XPUT filename. This should always be provided if client_cert is provided and match the certificate or client authentication will fail. The default value is ";;". This default value preserves the legacy behavior by allowing the creation of encrypted connections that are confidential but not authenticated. To specify a key stored outside of certs/, you can either use a relative path, for example ../server.pem or an absolute path starting with /flash, for example /flash/server.pem. Both examples refer to the same file. It is not an error at configuration time to name a file that does not yet exist. An error is generated if an attempt to create a TLS connection is made with improper settings. n Files specified should all be in PEM format, not DER. n Upload private keys securely with ATFS XPUT filename. n Certificates can be uploaded with ATFS PUT filename as they are not sensitive. It is not possible to use ATFS GET filename to GET them if they have been securely uploaded. To authenticate a server not participating in a public key infrastructure (PKI) using CAs, the server must present a self-signed certificate. That certificate can be used in the ca_cert field to authenticate that single server. There are effectively three levels of authentication provided depending on the parameters provided 1. No authentication: None of the parameters are provided, this is the default value. With this configuration identity is not validated and a man in the middle (MITM) attack is possible. 2. Server authentication: Only ca_cert is provided. Only the servers identity is checked 3. Mutual authentication: All items are provided and both sides are assured of the identity of their peer It is not possible to only have client authentication. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 109 Transport Layer Security (TLS) Transparent mode and TLS Transparent mode and TLS Transparent mode connections made when IP (IP Protocol) = 4 (TLS) are made using the configuration specified by $0 (SSL/TLS Profile 0). API mode and TLS On the Transmit (TX) Request: IPv4 - 0x20 frame, when you specify protocol 4 (TLS), the profile configuration specified by $0 (SSL/TLS Profile 0) is used to form the TLS connection. Tx Request with TLS Profile - 0x23 lets you choose the IP setting for the serial data. Key formats The RSA PKCS#1 format is the only common format across XBee Cellular device variants. You can identify a PKCS#1 key file by the presence of BEGIN RSA PRIVATE KEY in the file header. Digi's implementation does not support encrypted keys, we use file system encryption to protect the keys at rest in the system. Certificate formats The XBee3 Cellular LTE-M Global Smart Modem and the XBee Cellular 3G Global Embedded Modem do not support X509 v3 certificates and extensions for the client certificate. However, v3 certificates are fine for CA certificates used in server authentication. Certificate limitations The XBee Smart Modem only supports certificate files that contain a single certificate in them. The implications of this are: n For client certificate files (for example when client authentication is required): l Self-signed certificates will work. l Certificates signed by the root CA will work, because the root CA can be omitted per RFC 5246. The root certificate authority may be omitted from the chain, under the assumption that the remote end must already possess it in order to validate it in any case. l Certificate chains that include a intermediate CA are problematic. To work around this the client's certificate chain has to be supplied to the server outside of the connection. n For server certificate files (when server authentication is required) this is not a problem unless the client is expected to connect to multiple servers that are using different self signed certificates or are using certificate chains that are signed by different root CA certificates. To work around this you have to change the certificates before making the connection, or in the case of API mode specify a different authentication profile. Cipher suites The only documented shared suites between the XBee3 Cellular LTE Cat 1 Smart Modem and the XBee3 Cellular LTE-M Global Smart Modem are: Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 110 Transport Layer Security (TLS) n TLS_RSA_WITH_AES_128_CBC_SHA n TLS_RSA_WITH_AES_256_CBC_SHA Server Name Indication (SNI) For the Telit LE866 cellular component: n TLS_RSA_WITH_RC4_128_MD5 n TLS_RSA_WITH_RC4_128_SHA n TLS_RSA_WITH_AES_128_CBC_SHA n TLS_RSA_WITH_NULL_SHA n TLS_RSA_WITH_AES_256_CBC_SHA This list may be incomplete. Server Name Indication (SNI) We do not currently support SNI. Therefore servers which use SNI to present certificates based on client provided host data may be unable to establish the expected connections. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 111 AT commands Special commands Cellular commands Network commands Addressing commands Serial interfacing commands I/O settings commands I/O sampling commands Sleep commands Command mode options MicroPython commands Firmware version/information commands Diagnostic interface commands Execution commands File system commands Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 113 114 117 120 123 125 133 135 136 137 138 140 143 143 112 AT commands Special commands Special commands The following commands are special commands. AC (Apply Changes) Immediately applies new settings without exiting Command mode. Applying changes means that the device re-initializes based on changes made to its parameter values. Once changes are applied, the device immediately operates according to the new parameter values. This behavior is in contrast to issuing the WR (Write) command. The WR command saves parameter values to non-volatile memory, but the device still operates according to previously saved values until the device is rebooted or you issue the CN (Exit AT Command Mode) or AC commands. Parameter range N/A Default N/A FR (Force Reset) Resets the device. The device responds immediately with an OK and performs a reset 100 ms later. If you issue FR while the device is in Command Mode, the reset effectively exits Command mode. Note We recommend entering Airplane mode before resetting or rebooting the device to allow the cellular module to detach from the network. Parameter range N/A Default N/A RE command Restore device parameters to factory defaults. The RE command does not write restored values to non-volatile (persistent) memory. Issue the WR (Write) command after issuing the RE command to save restored parameter values to non-volatile memory. Parameter range N/A Default N/A WR (Write) Writes parameter values to non-volatile memory so that parameter modifications persist through subsequent resets. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 113 AT commands Cellular commands Note Once you issue a WR command, do not send any additional characters to the device until after you receive the OK response. Parameter range N/A Default N/A Cellular commands The following AT commands are cellular configuration and data commands. PH (Phone Number) Reads the SIM card phone number. If PH is blank, the XBee Smart Modem is not registered to the network. Parameter range N/A Default Set by the cellular carrier via the SIM card S# (ICCID) Reads the Integrated Circuit Card Identifier (ICCID) of the inserted SIM. Parameter range N/A Default Set by the SIM card IM (IMEI) Reads the device's International Mobile Equipment Identity (IMEI). Parameter range N/A Default Set in the factory MN (Operator) Reads the network operator on which the device is registered. Parameter range N/A Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 114 AT commands Cellular commands Default AT&T MV (Modem Firmware Version) Read the firmware version string for cellular component communications. See the related VR (Firmware Version) command. Parameter range N/A Default Set in the currently loaded firmware DB (Cellular Signal Strength) Reads the absolute value of the current signal strength to the cell tower in dB. If DB is blank, the XBee Smart Modem has not received a signal strength from the cellular component. Parameter range 0x71 - 0x33 (-113 dBm to -51 dBm) [read-only] Default N/A AN (Access Point Name) Specifies the packet data network that the modem uses for Internet connectivity. This information is provided by your cellular network operator. After you set this value, applying changes with AC (Apply Changes) or CN (Exit Command mode) triggers a network reset. Parameter range 1 - 100 ASCII characters Default - CP (Carrier Profile) Configures the cellular component to select network operator settings (RF bands, packet data configuration) for various networks. The default setting of 0 (autodetect) increases the boot time. Changes to the value only take effect on boot so a reboot or power cycle is required for any changes to become active. Parameter range 0-3 Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 115 AT commands Cellular commands Value Description 0 Autodetect from inserted ICCID (SIM) [default] 1 Reserved 2 AT&T 3 Verizon Default 0 OA (Operating APN) Reads the APN value currently configured in the cellular component. Parameter range ASCII characters Default N/A AM (Airplane Mode) When set, the cellular component of the XBee Smart Modem is fully turned off and no access to the cellular network is performed or possible. Parameter range 0-1 0 = Normal operation 1 = Airplane mode Default 0 DV (Antenna Diversity) Set and read the antenna diversity setting of the cellular component. When enabled, the cellular component uses both antennas to improve receive sensitivity. This setting is applied only while the XBee Smart Modem is initializing the cellular component. After changing this setting, you must: 1. Use WR (Write) to write all values to flash. 2. Use FR (Force Reset) to reset the device. 3. Wait for the cellular component to be initialized: AI (Association Indication) reaches 0x00. 4. Use FR to reset the device a second time. 5. Wait again for the cellular component to initialize: AI reaches 0x00. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 116 AT commands Network commands Parameter range 0-1 0 - diversity disabled 1 - diversity enabled Default 1 Network commands The following commands are network commands. IP (IP Protocol) Sets or displays the IP protocol used for client and server socket connections in IP socket mode. Parameter range 0-4 Value Description 0x00 UDP 0x01 TCP 0x02 SMS 0x03 Reserved 0x04 SSL over TCP communication Default 0x01 TL (SSL/TLS Protocol Version) Sets the SSL/TLS protocol version used for the SSL socket. If you change the TL value, it does not affect any currently open sockets. The value only applies to subsequently opened sockets. Note Due to known vulnerabilities in prior protocol versions, we strongly recommend that you use the latest TLS version whenever possible. Range Value Description 0x00 SSL v3 0x01 TLS v1.0 Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 117 AT commands Network commands Value Description 0x02 TLS v1.1 0x03 TLS v1.2 Default 0x03 $0 (SSL/TLS Profile 0) Specifies the SSL/TLS certificate(s) to use in Transparent mode (when IP (IP Protocol) = 4) or API mode (Transmit (TX) Request: IPv4 - 0x20 or Tx Request with TLS Profile - 0x23 with profile set to 0). Format server_cert;client_cert;client_key Parameter range From 1 through 127 ASCII characters. Default N/A $1 (SSL/TLS Profile 1) Specifies the SSL/TLS certificate(s) to use for Tx Request with TLS Profile - 0x23 transmissions with profile set to 1. Format server_cert;client_cert;client_key Parameter range From 1 through 127 ASCII characters. Default N/A $2 (SSL/TLS Profile 2) Specifies the SSL/TLS certificate(s) to use in Transparent mode (when IP (IP Protocol) = 4) or API mode (Transmit (TX) Request: IPv4 - 0x20 or Tx Request with TLS Profile - 0x23 with profile set to 0). Format server_cert;client_cert;client_key Parameter range From 1 through 127 ASCII characters. Default N/A Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 118 AT commands Network commands TM (IP Client Connection Timeout) The IP client connection timeout. If there is no activity for this timeout then the connection is closed. If TM is 0, the connection is closed immediately after the device sends data. If you change the TM value while in Transparent Mode, the current connection is immediately closed. Upon the next transmission, the TM value applies to the newly created socket. If you change the TM value while in API Mode, the value only applies to subsequently opened sockets. Parameter range 0 - 0xFFFF [x 100 ms] Default 0xBB8 (5 minutes) TS (IP Server Connection Timeout) The IP server connection timeout. If no activity for this timeout then the connection is closed. When set to 0 the connection is closed immediately after data is sent.] Parameter Range 10 - 0xFFFF; (x 100 ms) Default 3000 DO (Device Options) Enables and disables special features on the XBee Smart Modem. Bit 0 - Remote Manager support If the XBee Smart Modem cannot establish a connection with Remote Manager, it waits 30 seconds before trying again. On each successive connection failure, the wait time doubles (60 seconds, 120, 240, and so on) up to a maximum of 1 hour. This time resets to 30 seconds once the connection to Remote Manager succeeds or if the device is reset. Bits 1 - 7 Reserved Range 0x00 - 0x07 Bitfield Bit Description 0x00 Disable Remote Manager support 0x01 Enable Remote Manager support Default 0x01 Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 119 AT commands Addressing commands EQ (Remote Manager FQDN) Sets or display the fully qualified domain name of the Remote Manager server. Range From 0 through 63 ASCII characters. Default my.devicecloud.com Addressing commands The following AT commands are addressing commands. SH (Serial Number High) The upper digits of the unique International Mobile Equipment Identity (IMEI) assigned to this device. Parameter range 0 - 0xFFFFFFFF [read-only] Default N/A SL (Serial Number Low) The lower digits of the unique International Mobile Equipment Identity (IMEI) assigned to this device. Parameter range 0 - 0xFFFFFFFF [read-only] Default N/A MY (Module IP Address) Reads the device's IP address. This command is read-only because the IP address is assigned by the mobile network. In API mode, the address is represented as the binary four byte big-endian numeric value representing the IPv4 address. In Transparent or Command mode, the address is represented as a dotted-quad string notation. Parameter range 0- 15 IPv4 characters Default 0.0.0.0 Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 120 AT commands Addressing commands P# (Destination Phone Number) Sets or displays the destination phone number used for SMS when IP (IP Protocol) = 2. Phone numbers must be fully numeric, 7 to 20 ASCII digits, for example: 8889991234. P# allows international numbers with or without the + prefix. If you omit + and are dialing internationally, you need to include the proper International Dialing Prefix for your calling region, for example, 011 for the United States. Range 7 - 20 ASCII digits including an optional + prefix Default N/A N1 (DNS Address) Displays the IPv4 address of the primary domain name server. Parameter Range Read-only Default 0.0.0.0 (waiting on cellular connection) N2 (DNS Address) Displays the IPv4 address of the secondary domain name server. Parameter Range Read-only Default 0.0.0.0 (waiting on cellular connection) DL (Destination Address) The destination IPv4 address or fully qualified domain name. To set the destination address to an IP address, the value must be a dotted quad, for example XXX.XXX.XXX.XXX. To set the destination address to a domain name, the value must be a legal Internet host name, for example remotemanager.digi.com Parameter range 0 - 128 ASCII characters Default 0.0.0.0 Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 121 AT commands Addressing commands OD (Operating Destination Address) Read the destination IPv4 address currently in use by Transparent mode. The value is 0.0.0.0 if no Transparent IP connection is active. In API mode, the address is represented as the binary four byte big-endian numeric value representing the IPv4 address. In Transparent or Command mode, the address is represented as a dotted-quad string notation. Parameter range Default 0.0.0.0 DE (Destination Port) Sets or displays the destination IP port number. Parameter range 0x0 - 0xFFFF Default 0x2616 C0 (Source Port) Set or get the port number used to provide the serial communication service. Data received by this port on the network is transmitted on the XBee Smart Modem's serial port. As long as a network connection is established to this port (for TCP) data received on the serial port is transmitted on the established network connection. IP (IP Protocol) sets the protocol used when UART is in Transparent or API mode. For more information on using incoming connections, see Socket behavior. Parameter range 0 - 0xFFFF Value Description 0 Disabled Non-0 Enabled on that port Default 0 LA (Lookup IP Address of FQDN) Performs a DNS lookup of the given fully qualified domain name (FQDN) and outputs its IP address. When you issue the command in API mode, the IP address is formatted in binary four byte big-endian numeric value. In all other cases (for example, Command mode) the format is dotted decimal notation. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 122 AT commands Serial interfacing commands Range Valid FQDN Default - Serial interfacing commands The following AT commands are serial interfacing commands. BD (Baud Rate) Sets or displays the serial interface baud rate for communication between the device's serial port and the host. Modified interface baud rates do not take effect until the XBee Smart Modem exits Command mode or you issue AC (Apply Changes). The baud rate resets to default unless you save it with WR (Write) or by clicking the Write module settings button in XCTU. Parameter range Standard baud rates: 0x1 - 0x8 Non-standard baud rates: 0x5B9 to 0x3D090 (250,000 b/s) Parameter Description 0x0 1200 b/s 0x1 2400 b/s 0x2 4800 b/s 0x3 9600 b/s 0x4 19200 b/s 0x5 38400 b/s 0x6 57600 b/s 0x7 115200 b/s 0x8 230400 b/s Default 0x3 (9600 b/s) NB (Parity) Set or read the serial parity settings for UART communications. Parameter range 0x00 - 0x02 Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 123 AT commands Serial interfacing commands Parameter Description 0x00 No parity 0x01 Even parity 0x02 Odd parity Default 0x00 SB (Stop Bits) Sets or displays the number of stop bits for UART communications. Parameter range 0-1 Parameter Configuration 0 One stop bit 1 Two stop bits Default 0 RO (Packetization Timeout) Set or read the number of character times of inter-character silence required before transmission begins when operating in Transparent mode. RF transmission also starts after 100 bytes (maximum packet size) are received in the DI buffer. Set RO to 0 to transmit characters as they arrive instead of buffering them into one RF packet. Parameter range 0 - 0xFF (x character times) Default 3 TD (Text Delimiter) The ASCII character used as a text delimiter for Transparent mode. When you select a character, information received over the serial port in Transparent mode is not transmitted until that character is received. To use a carriage return, set to 0xD. Set to zero to disable text delimiter checking. Parameter range 0 - 0xFF Default 0x0 Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 124 AT commands I/O settings commands FT (Flow Control Threshold) Set or display the flow control threshold. The device de-asserts CTS when FT bytes are in the UART receive buffer. Parameter range 0x9D - 0x82D Default 0x681 AP (API Enable) The API mode setting. The device can format the RF packets it receives into API frames and send them out the UART. When API is enabled the UART data must be formatted as API frames because Transparent mode is disabled. See Modes for more information. Parameter range 0x00 - 0x05 Parameter Description 0x00 API disabled (operate in Transparent mode) 0x01 API enabled 0x02 API enabled (with escaped control characters) 0x03 N/A 0x04 MicroPython REPL 0x05 Bypass mode Default 0 I/O settings commands The following AT commands are I/O settings commands. D0 (DIO0/AD0) Sets or displays the DIO0/AD0 configuration (pin 20). Parameter range 0, 2 - 5 Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 125 AT commands I/O settings commands Parameter Description 0 Disabled 1 N/A 2 Analog input 3 Digital input 4 Digital output, default low 5 Digital output, default high Default 0 D1 (DIO1/AD1) Sets or displays the DIO1/AD1 configuration (pin 19). Parameter range 0-6 Parameter Description 0 Disabled 1 SPI_ATTN 2 ADC 3 Digital input 4 Digital output, low 5 Digital output, high 6 I2C SCL Default 0 D2 (DIO2/AD2) Sets or displays the DIO2/AD2 configuration (pin 18). Parameter range 0-5 Description 0 Disabled Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 126 AT commands I/O settings commands Description 1 SPI_CLK 2 Analog input 3 Digital input 4 Digital output, default low 5 Digital output, default high Default 0 D3 (DIO3/AD3) Sets or displays the DIO3/AD3 configuration (pin 17). Parameter range 0-5 Parameter Description 0 Disabled 1 SPI_SSEL 2 Analog input 3 Digital input 4 Digital output, default low 5 Digital output, default high Default 0 D4 (DIO4) Sets or displays the DIO4 configuration (pin 11). Parameter range 0, 1, 3 - 5 Parameter Description 0 Disabled 1 SPI_MOSI 2 N/A Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 127 AT commands I/O settings commands Parameter Description 3 Digital input 4 Digital output, default low 5 Digital output, default high Default 0 D5 (DIO5/ASSOCIATED_INDICATOR) Sets or displays the DIO5/ASSOCIATED_INDICATOR configuration (pin 15). Parameter range 0, 1, 3 - 5 Parameter Description 0 Disabled 1 Associated LED 2 N/A 3 Digital input 4 Digital output, default low 5 Digital output, default high Default 1 D6 (DIO6/RTS) Sets or displays the DIO6/RTS configuration (pin 16). Parameter range 0, 1, 3 - 5 Parameter Description 0 Disabled 1 RTS flow control 2 N/A 3 Digital input 4 Digital output, default low 5 Digital output, default high Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 128 AT commands I/O settings commands Default 0 D7 (DIO7/CTS) Sets or displays the DIO7/CTS configuration (pin 12). Parameter range 0, 1, 3 - 5 Parameter Description 0 Disabled 1 CTS flow control 2 N/A 3 Digital input 4 Digital output, default low 5 Digital output, default high Default 0x1 D8 (DIO8/SLEEP_REQUEST) Sets or displays the DIO8/DTR/SLP_RQ configuration (pin 9). Parameter range 0, 1, 3 - 5 Parameter Description 0 Disabled 1 SLEEP_REQUEST input 3 Digital input 4 Digital output, default low 5 Digital output, default high Default 1 Sets or displays the DIO9/ON_SLEEP configuration (pin 13). Parameter range 0, 1, 3 - 5 Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 129 AT commands I/O settings commands Parameter Description 0 Disabled 1 ON/SLEEP output 3 Digital input 4 Digital output, default low 5 Digital output, default high Default 1 P0 (DIO10/PWM0 Configuration) Sets or displays the PWM/DIO10 configuration (pin 6). This command enables the option of translating incoming data to a PWM so that the output can be translated back into analog form. Parameter range 0-5 Parameter Description 0 Disabled 1 RSSI PWM0 output 2 PWM0 output 3 Digital input 4 Digital output, low 5 Digital output, high Default 0 P1 (DIO11/PWM1 Configuration) Sets or displays the DIO11 configuration (pin 7). Parameter range 0, 1, 3 - 6 Parameter Description 0 Disabled Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 130 AT commands I/O settings commands Parameter Description 1 Fan enable. Output is low when the XBee Smart Modem is sleeping, turning an attached fan off when the cellular component is in a power saving mode, and also during Airplane Mode 3 Digital input 4 Digital output, default low 5 Digital output, default high 6 I2C SDA 7 USB direct Default 0 P2 (DIO12 Configuration) Sets or displays the DIO12 configuration (pin 4). Parameter range 0, 1, 3 - 5 Parameter Description 0 Disabled 1 SPI_MISO 2 N/A 3 Digital input 4 Digital output, default low 5 Digital output, default high Default 0 P3 (DIO13/DOUT) Sets or displays the DIO13/DOUT configuration (pin 17). Parameter range 0, 1 Parameter Description 0 Disabled 1 UART DOUT enabled Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 131 AT commands I/O settings commands Default 1 P4 (DIO14/DIN) Sets or displays the DIO14/DIN configuration (pin 3). Parameter range 0-1 Parameter Description 0 Disabled 1 UART DIN enabled Default 1 PD (Pull Direction) The resistor pull direction bit field (1 = pull-up, 0 = pull-down) for corresponding I/O lines that are set by PR (Pull-up/down Resistor Enable). If the bit is not set in PR, the device uses PD. Note Resistors are not applied to disabled lines. See PR (Pull-up/down Resistor Enable) for bit mappings, which are the same. Parameter range 0x0 – 0x7FFF Default 0 – 0x7FFF PR (Pull-up/down Resistor Enable) Sets or displays the bit field that configures the internal resistor status for the digital input lines. Internal pull-up/down resistors are not available for digital output pins, analog input pins, or for disabled pins. Use the PD command to specify whether the resistor is pull-up or pull-down. n If you set a PR bit to 1, it enables the pull-up/down resistor. n If you set a PR bit to 0, it specifies no internal pull-up/down resistor. The following table defines the bit-field map for both the PR and PD commands. Bit I/O line Module pin 0 DIO4 pin 11 Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 132 AT commands I/O sampling commands Bit I/O line Module pin 1 DIO3/AD3 pin 17 2 DIO2/AD2 pin 18 3 DIO1/AD1 pin 19 4 DIO0/AD0 pin 20 5 DIO6/RTS pin 16 6 DIO8/SLEEP_REQUEST pin 9 7 DIO14/DIN pin 3 8 DIO5/ASSOCIATE pin 15 9 DIO9/On/SLEEP pin 13 10 DIO12 pin 4 11 DIO10 pin 6 12 DIO11 pin 7 13 DIO7/CTS pin 12 14 DIO13/DOUT pin 17 Parameter range 0 - 0x7FFF (bit field) Default 0x7FFF M0 (PWM0 Duty Cycle) Sets the duty cycle of PWM0 (pin 6) for P0 = 2, where a value of 0x200 is a 50% duty cycle. Before setting the line as an output: 1. Enable PWM0 output (P0 (DIO10/PWM0 Configuration) = 2). 2. Apply the settings (use CN (Exit Command mode) or AC (Apply Changes)). The PWM period is 42.62 µs and there are 0x03FF (1023 decimal) steps within this period. When M0 = 0 (0% PWM), 0x01FF (50% PWM), 0x03FF (100% PWM), and so forth. Parameter range 0 - 0x3FF Default 0 I/O sampling commands The following AT commands configure I/O sampling parameters. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 133 AT commands I/O sampling commands TP (Temperature) Displays the temperature of the XBee Smart Modem in degrees Celsius. The temperature value is displayed in 8-bit two’s complement format. For example, 0x1A = 26 °C, and 0xF6 = -10 °C. Parameter range 0 - 0xFF which indicates degrees Celsius displayed in 8-bit two's complement format. Default N/A IS (Force Sample) When run, IS reports the values of all of the enabled digital and analog input lines. If no lines are enabled for digital or analog input, the command returns an error. Command mode In Command mode, the response value is a multi-line format, individual lines are delimited with carriage returns, and the entire response terminates with two carriage returns. Each line is a series of ASCII characters representing a single number in hexadecimal notation. The interpretation of the lines is: n Number of samples. For legacy reasons this field always returns 1. n Digital channel mask. A bit-mask of all I/O capable pins in the system. The bits set to 1 are configured for digital I/O and are included in the digital data value below. Pins D0 - D9 are bits 0 - 9, and P0 - P2 are bits 10 - 12. n Analog channel mask. The bits set to 1 are configured for analog I/O and have individual readings following the digital data field. n Digital data. The current digital value of all the pins set in the digital channel mask, only present if at least one bit is set in the digital channel mask. n Analog data. Additional lines, one for each set pin in the analog channel mask. Each reading is a 10-bit ADC value for a 2.5 V voltage reference. API operating mode In API operating mode, IS immediately returns an OK response. The API response is ordered identical to the Command mode response with the same fields present. Each field is a binary number of the size listed in the following table. Multi-byte fields are in big-endian byte order. Field Size Number of samples 1 byte Digital channel mask 2 bytes Analog chanel mask 1 byte Samples 2 bytes each Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 134 AT commands Sleep commands Parameter range N/A Default N/A Sleep commands The following AT commands are sleep commands. SM (Sleep Mode) Sets or displays the sleep mode of the device. The sleep mode determines how the device enters and exits a power saving sleep. Sleep mode is also affected by the SO command, option bit 6. See Sleep modes for more information about sleep modes. Parameter range 0, 1, 4, 5 Parameter Description 0 Normal. In this mode the device never sleeps. 1 Pin Sleep. In this mode the device honors the SLEEP_RQ pin. Set D8 (DIO8/SLEEP_ REQUEST) to the sleep request function: 1. 4 Cyclic Sleep. In this mode the device repeatedly sleeps for the value specified by SP and spends ST time awake. 5 Cyclic Sleep with Pin Wake. In this mode the device acts as in Cyclic Sleep but does not sleep if the SLEEP_RQ pin is inactive, allowing the device to be kept awake or woken by the connected system. Default 0 SP (Sleep Period) Sets or displays the time to spend asleep in cyclic sleep modes. In Cyclic sleep mode, the node sleeps with CTS disabled for the sleep time interval, then wakes for the wake time interval. Parameter range 0x1 - 0x83D600 (x 10 ms) Default 0x7530 (5 minutes) ST (Wake Time) Sets or displays the time to spend awake in cyclic sleep modes. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 135 AT commands Command mode options Parameter range 0x1 - 0x36EE80 (x 1 ms) Default 0xEA60 (60 seconds) SO (Sleep Options) Set or read the sleep options bit field of a device. This command is a bitmask. Parameter range 0x0 - 0xFFFF Bit field: Bit Setting Meaning 0x00 0 Description Connected On compatible hardware, enters a lower power consumption mode sleep that maintains registration with the cellular network. Set all other option bits to 0. Default 0 Command mode options The following commands are Command mode option commands. CC (Command Sequence Character) The character value the device uses to enter Command mode. The default value (0x2B) is the ASCII code for the plus (+) character. You must enter it three times within the guard time to enter Command mode. To enter Command mode, there is also a required period of silence before and after the command sequence characters of the Command mode sequence (GT + CC + GT). The period of silence prevents inadvertently entering Command mode. Parameter range 0 - 0xFF Default 0x2B (the ASCII plus character: +) CT (Command Mode Timeout) Sets or displays the Command mode timeout parameter. If a device does not receive any valid commands within this time period, it returns to Idle mode from Command mode. Parameter range 2 - 0x1770 (x 100 ms) Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 136 AT commands MicroPython commands Default 0x64 (10 seconds) CN (Exit Command mode) Immediately exits Command Mode and applies pending changes. Note Whether Command mode is exited using the CN command or by CT timing out, changes are applied upon exit. Parameter range N/A Default N/A GT (Guard Times) Set the required period of silence before and after the command sequence characters of the Command mode sequence (GT + CC + GT). The period of silence prevents inadvertently entering Command mode. Parameter range 0x2 - 0x6D3 (x 1 ms) Default 0x3E8 (one second) MicroPython commands The following commands relate to using MicroPython on the XBee Smart Modem. PS (Python Startup) Sets whether or not the XBee Smart Modem runs the stored Python code at startup. Range 0-1 Parameter Description 0 Do not run stored Python code at startup. 1 Run stored Python code at startup. Default 0 Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 137 AT commands Firmware version/information commands PY (MicroPython Command) Interact with the XBee Smart Modem using MicroPython. PY is a command with sub-commands. These sub-commands are arguments to PY. PYC(Code Report) You can store compiled code in flash using the Ctrl-F command from the MicroPython REPL; refer to the Digi MicroPython Programming Guide. The PYC sub-command reports details of the stored code. In Command mode, it returns three lines of text, for example: source: 1662 bytes (hash=0xC3B3A813) bytecode: 619 bytes (hash=0x0900DBCE) compiled: 2017-05-09T15:49:44 The messages are: n source: the size of the source code used to generate the bytecode and its 32-bit hash. n bytecode: the size of bytecode stored in flash and its 32-bit hash. A size of 0 indicates that there is no stored code. n compiled: a compilation timestamp. A timestamp of 2000-01-01T00:00:00 indicates that the clock was not set during compilation. In API mode, PYC returns five 32-bit big-endian values: n source size n source hash n bytecode size n bytecode hash n timestamp as seconds since 2000-01-01T00:00:00 PYD (Delete Code) PYD interrupts any running code, erases any stored code and then does a soft-reboot on the MicroPython subsystem. PYV (Version Report) Report the MicroPython version. PY^ (Interrupt Program) Sends KeyboardInterrupt to MicroPython. This is useful if there is a runaway MicroPython program and you have filled the stdin buffer. You can enter Command mode (+++) and send ATPY^ to interrupt the program. Default N/A Firmware version/information commands The following AT commands are firmware version/information commands. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 138 AT commands Firmware version/information commands VR (Firmware Version) Reads the firmware version on a device. Parameter range 0 - 0xFFFF [read-only] Default Set in firmware VL (Verbose Firmware Version) Shows detailed version information including the application build date and time. Parameter range N/A Default Set in firmware HV (Hardware Version) Display the hardware version number of the device. Parameter range 0 - 0xFFFF [read-only] Default Set in firmware AI (Association Indication) Reads the Association status code to monitor association progress. The following table provides the status codes and their meanings. Status code Meaning 0x00 Connected to the Internet. 0x22 Registering to cellular network. 0x23 Connecting to the Internet. 0x24 The cellular component is missing, corrupt, or otherwise in error. The cellular component requires a new firmware image. 0x25 Cellular network registration denied. 0x2A Airplane mode. 0x2B USB Direct active. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 139 AT commands Diagnostic interface commands Status code Meaning 0x2F Bypass mode active. 0xFF Initializing. Parameter range 0 - 0xFF [read-only] Default N/A HS (Hardware Series) Read the device's hardware series number. Parameter range N/A Default Set in the firmware CK (Configuration CRC) Displays the cyclic redundancy check (CRC) of the current AT command configuration settings. Parameter range 0 - 0xFFFFFFFF Default N/A Diagnostic interface commands The following AT commands are diagnostic interface commands. DI (Remote Manager Indicator) Displays the current Remote Manager status for the XBee. Range Value Description 0x00 Connected 0x01 Before connection to the Internet 0x02 Remote Manager connection in progress Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 140 AT commands Diagnostic interface commands Value Description 0x03 Disconnecting from Remote Manager 0x04 Not configured for Remote Manager Default N/A CI (Protocol/Connection Indication) Displays information regarding the last IP connection (when the IP command = 0, 1 or 4) or SMS transmission (when IP = 2). The value for this parameter resets to 0xFF when the device switches between IP (IP Protocol) modes. When IP is set to 0, 1, or 4 (UDP, TCP, over SSL over TCP), CI resets to 0xFF when you apply changes to any of the following settings: n DL (Destination Address) n DE (Destination Port) n TM (IP Client Connection Timeout) When IP is set to 2 (SMS), CI resets to 0xFF when P# (Destination Phone Number) is changed. The following table provides the parameter's meaning when IP = 0 for UDP connections. Parameter Description 0x00 The socket is open. 0x01 Tried to send but could not. 0x02 Invalid parameters (bad IP/host). 0x03 TCP not supported on this cellular component. 0x10 Not registered to the cell network. 0x11 Cellular component not identified yet. 0x12 DNS query lookup failure. 0x13 Socket leak 0x20 Bad handle. 0x21 User closed. 0x22 Unknown server - DNS lookup failed. 0x23 Connection lost. 0x24 Unknown. 0xFF No known status. The following table provides the parameter's meaning when IP = 1 or 4 for TCP connections. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 141 AT commands Diagnostic interface commands Parameter Description 0x00 The socket is open. 0x01 Tried to send but could not. 0x02 Invalid parameters (bad IP/host). 0x03 TCP not supported on this cellular component. 0x10 Not registered to the cell network. 0x11 Cellular component not identified yet. 0x12 DNS query lookup failure. 0x13 Socket leak 0x20 Bad handle. 0x21 User closed. 0x22 No network registration. 0x23 No internet connection. 0x24 No server - timed out on connection. 0x25 Unknown server - DNS lookup failed. 0x26 Connection refused. 0x27 Connection lost. 0x28 Unknown. 0xFF No known status. The following table provides the parameter's meaning when IP = 2 for SMS connections. Parameter Description 0x00 SMS successfully sent. 0x01 SMS failed to send. 0x02 Invalid SMS parameters - check P# (Destination Phone Number). 0x03 SMS not supported. 0x10 No network registration. 0x11 Cellular component stack error. 0x13 Socket leak 0xFF No SMS state to report (no SMS messages have been sent). Parameter range 0 - 0xFF (read-only) Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 142 AT commands Execution commands Default - Execution commands The location where most AT commands set or query register values, execution commands execute an action on the device. Execution commands are executed immediately and do not require changes to be applied. NR (Network Reset) NR resets the network layer parameters. The XBee Smart Modem responds immediately with an OK on the UART and then causes a network restart. If NR = 0, the XBee Smart Modem tears down any TCP/UDP sockets and resets Internet connectivity. You can also send NR, which acts like NR = 0. Parameter range 0 Default N/A !R (Modem Reset) Forces the cellular component to reboot. CAUTION! This command is for advanced users, and you should only use it if the cellular component becomes completely stuck while in Bypass mode. Normal users should never need to run this command. See the FR (Force Reset) command instead. Range N/A Default N/A File system commands To access the file system, Enter Command mode and use the following commands. All commands block the AT command processor until completed and only work from Command mode; they are not valid for API mode or MicroPython's xbee.atcmd() method. Commands are case-insensitive as are file and directory names. Optional parameters are shown in square brackets ([]). FS is a command with sub-commands. These sub-commands are arguments to FS. For FS commands, you have to type AT before the command, for example ATFS PWD, ATFS LS and so forth. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 143 AT commands File system commands Error responses If a command succeeds it returns information such as the name of the current working directory or a list of files, or OK if there is no information to report. If it fails, you see a detailed error message instead of the typical ERROR response for a failing AT command. The response is a named error code and a textual description of the error. Note The exact content of error messages may change in the future. All errors start with a capital E, followed by one or more uppercase letters and digits, a space, and an description of the error. If writing your own AT command parsing code, you can determine if an FS command response is an error by checking if the first letter of the response is capital E. ATFS (File System) When sent without any parameters, FS prints a list of supported commands. ATFS PWD Prints the current working directory, which always starts with / and defaults to /flash at startup. ATFS CD directory Changes the current working directory to directory. Prints the current working directory or an error if unable to change to directory. ATFS MD directory Creates the directory directory. Prints OK if successful or an error if unable to create the requested directory. ATFS LS [directory] Lists files and directories in the specified directory. The directory parameter is optional and defaults to a period (.), which represents the current directory. The list ends with a blank line. Entries start with zero or more spaces, followed by filesize or the string for directories, then a single space character and the name of the entry. Directory names end with a forward slash (/) to differentiate them from files. Secure files end with a hash mark (#) and you cannot download them. 32 1234 ./ ../ cert/ lib/ test.txt secure.bin# ATFS PUT filename Starts a YMODEM receive on the XBee Smart Modem, storing the received file to filename and ignoring the filename that appears in block 0 of the YMODEM transfer. The XBee Smart Modem sends a prompt (Receiving file with YMODEM...) when it is ready to receive, at which point you should initiate a YMODEM send in your terminal emulator. If the command is incorrect, the reply will be an error as described in Error responses. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 144 AT commands File system commands ATFS XPUT filename Similar to the PUT command, but stores the file securely on the XBee Smart Modem. See Secure files for details on what this means. If the command is incorrect, the reply will be an error as described in Error responses. ATFS HASH filename Print a sha256 hash of a secure file uploaded via the XPUT command to allow for verification against a local copy of the file. On Windows, you can generate a SHA256 hash of a file with the command certutil -hashfile test.txt SHA256. On Mac and Linux use shasum -b -a 256 test.txt. ATFS GET filename Starts a YMODEM send of filename on the XBee device. When it is ready to send, the XBee Smart Modem sends a prompt: (Sending file with YMODEM...). When the prompt is sent, you should initiate a YMODEM receive in your terminal emulator. If the command is incorrect, the reply will be an error as described in Error responses. ATFS MV source_path dest_path Moves or renames the selected file or directory source_path to the new name or location dest_ path. This command fails with an error if source_path does not exist, or dest_path already exists. Note Unlike a computer's command prompt which moves a file into the dest_path if it is an existing directory, you must specify the full name for dest_path. ATFS RM file_or_directory Removes the file or empty directory specified by file_or_directory. This command fails with an error if file_or_directory does not exist, is not empty, refers to the current working directory or one of its parents. ATFS INFO Report on the size of the filesystem, showing bytes in use, available, marked bad and total. The report ends with a blank line, as with most multi-line AT command output. Example output: 204800 used 695296 free 0 bad 900096 total ATFS FORMAT confirm Reformats the file system, leaving it with a default directory structure. Pass the word confirm as the first parameter to confirm the format. The XBee Smart Modem responds with Formatting..., adds a period every second until the format is complete and ends the response with a carriage return. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 145 Operate in API mode API mode overview Use the AP command to set the operation mode API frame format Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 147 147 147 146 Operate in API mode API mode overview API mode overview As an alternative to Transparent operating mode, you can use API operating mode. API mode provides a structured interface where data is communicated through the serial interface in organized packets and in a determined order. This enables you to establish complex communication between devices without having to define your own protocol. The API specifies how commands, command responses and device status messages are sent and received from the device using the serial interface or the SPI interface. We may add new frame types to future versions of firmware, so build the ability to filter out additional API frames with unknown frame types into your software interface. Use the AP command to set the operation mode Use AP (API Enable) to specify the operation mode: AP command setting Description AP = 0 Transparent operating mode, UART serial line replacement with API modes disabled. This is the default option. AP = 1 API operation. AP = 2 API operation with escaped characters (only possible on UART). AP = 3 N/A AP = 4 MicroPython REPL AP = 5 Bypass mode. This mode is for direct communication with the underlying chip and is only for advanced users. The API data frame structure differs depending on what mode you choose. API frame format An API frame consists of the following: n Start delimeter n Length n Frame data n Checksum API operation (AP parameter = 1) This is the recommended API mode for most applications. The following table shows the data frame structure when you enable this mode: Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 147 Operate in API mode API frame format Frame fields Byte Description Start delimiter 1 0x7E Length 2-3 Most Significant Byte, Least Significant Byte Frame data 4 - number (n) API-specific structure Checksum n+1 1 byte Any data received prior to the start delimiter is silently discarded. If the frame is not received correctly or if the checksum fails, the XBee replies with a radio status frame indicating the reason for the failure. API operation with escaped characters (AP parameter = 2) Setting API to 2 allows escaped control characters in the API frame. Due to its increased complexity, we only recommend this API mode in specific circumstances. API 2 may help improve reliability if the serial interface to the device is unstable or malformed frames are frequently being generated. When operating in API 2, if an unescaped 0x7E byte is observed, it is treated as the start of a new API frame and all data received prior to this delimiter is silently discarded. For more information on using this API mode, see the Escaped Characters and API Mode 2 in the Digi Knowledge base. API escaped operating mode works similarly to API mode. The only difference is that when working in API escaped mode, the software must escape any payload bytes that match API frame specific data, such as the start-of-frame byte (0x7E). The following table shows the structure of an API frame with escaped characters: Frame fields Byte Description Start delimiter 1 0x7E Length 2-3 Most Significant Byte, Least Significant Byte Frame data 4-n API-specific structure Checksum n + 1 1 byte Characters escaped if needed Start delimiter field This field indicates the beginning of a frame. It is always 0x7E. This allows the device to easily detect a new incoming frame. Escaped characters in API frames If operating in API mode with escaped characters (AP parameter = 2), when sending or receiving a serial data frame, specific data values must be escaped (flagged) so they do not interfere with the data frame sequencing. To escape an interfering data byte, insert 0x7D and follow it with the byte to be escaped (XORed with 0x20). The following data bytes need to be escaped: n 0x7E: start delimiter n 0x7D: escape character n 0x11: XON n 0x13: XOFF Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 148 Operate in API mode API frame format To escape a character: 1. Insert 0x7D (escape character). 2. Append it with the byte you want to escape, XORed with 0x20. In API mode with escaped characters, the length field does not include any escape characters in the frame and the firmware calculates the checksum with non-escaped data. Example: escape an API frame To express the following API non-escaped frame in API operating mode with escaped characters: Frame Data Start delimiter Length Frame type Checksum Data 7E 00 0F 17 01 00 13 A2 00 40 AD 14 2E FF FE 02 4E 49 6D You must escape the 0x13 byte: 1. Insert a 0x7D. 2. XOR byte 0x13 with 0x20: 13 ⊕ 20 = 33 The following figure shows the resulting frame. Note that the length and checksum are the same as the non-escaped frame. Frame Data Start delimiter Length Frame type Checksum Data 7E 00 0F 17 01 00 7D 33 A2 00 40 AD 14 2E FF FE 02 4E 49 6D The length field has a two-byte value that specifies the number of bytes in the frame data field. It does not include the checksum field. Length field The length field is a two-byte value that specifies the number of bytes contained in the frame data field. It does not include the checksum field. Frame data This field contains the information that a device receives or will transmit. The structure of frame data depends on the purpose of the API frame: Frame data Length Data 1 2 3 0x7E MSB LSB n 4 5 6 7 8 9 ... n n+1 Data Frame type is the API frame type identifier. It determines the type of API frame and indicates how the Data field organizes the information. n Data contains the data itself. This information and its order depend on the what type of frame that the Frame type field defines. Multi-byte values are sent big-endian. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 149 Operate in API mode API frame format Calculate and verify checksums To calculate the checksum of an API frame: 1. Add all bytes of the packet, except the start delimiter 0x7E and the length (the second and third bytes). 2. Keep only the lowest 8 bits from the result. 3. Subtract this quantity from 0xFF. To verify the checksum of an API frame: 1. Add all bytes including the checksum; do not include the delimiter and length. 2. If the checksum is correct, the last two digits on the far right of the sum equal 0xFF. Example Consider the following sample data packet: 7E 00 0A 01 01 50 01 00 48 65 6C 6C 6F B8+ Byte(s) Description 7E Start delimiter 00 0A Length bytes 01 API identifier 01 API frame ID 50 01 Destination address low 00 Option byte 48 65 6C 6C 6F Data packet B8 Checksum To calculate the check sum you add all bytes of the packet, excluding the frame delimiter 7E and the length (the second and third bytes): 7E 00 0A 01 01 50 01 00 48 65 6C 6C 6F B8 Add these hex bytes: 01 + 01 + 50 + 01 + 00 + 48 + 65 + 6C + 6C + 6F = 247 Now take the result of 0x247 and keep only the lowest 8 bits which in this example is 0xC4 (the two far right digits). Subtract 0x47 from 0xFF and you get 0x3B (0xFF - 0xC4 = 0x3B). 0x3B is the checksum for this data packet. If an API data packet is composed with an incorrect checksum, the XBee Smart Modem will consider the packet invalid and will ignore the data. To verify the check sum of an API packet add all bytes including the checksum (do not include the delimiter and length) and if correct, the last two far right digits of the sum will equal FF. 01 + 01 + 50 + 01 + 00 + 48 + 65 + 6C + 6C + 6F + B8 = 2FF Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 150 API frames The following sections describe the API frames. AT Command - 0x08 Transmit (TX) SMS - 0x1F Transmit (TX) Request: IPv4 - 0x20 Tx Request with TLS Profile - 0x23 AT Command Response - 0x88 Transmit (TX) Status - 0x89 Modem Status - 0x8A Receive (RX) Packet: SMS - 0x9F Receive (RX) Packet: IPv4 - 0xB0 Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 152 153 154 156 158 159 161 162 163 151 API frames AT Command - 0x08 AT Command - 0x08 Description Use this frame to query or set parameters on the local device. Changes this frame makes to device parameters take effect after executing the AT command. Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Field name Field Data value type Description Frame type 0x08 Byte Frame ID Byte Identifies the data frame for the host to correlate with a subsequent ACK. If set to 0, the device does not send a response. AT command Byte Command name: two ASCII characters that identify the AT command. Parameter value Byte If present, indicates the requested parameter value to set the given register. If no characters are present, it queries the register. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 152 API frames Transmit (TX) SMS - 0x1F Transmit (TX) SMS - 0x1F Description Transmit an SMS message. The frame allows international numbers with or without the + prefix. If you omit + and are dialing internationally, you need to include the proper International Dialing Prefix for your calling region, for example, 011 for the United States. Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Field name Field value Data type Description Frame type 0x1F Byte Frame ID Byte Reference identifier used to match status responses. 0 disables the TX Status frame. Options Byte Reserved for future use. Phone number 20 byte string String representation of phone number terminated with a null (0x0) byte. Use numbers and the + symbol only, no other symbols or letters. Payload Variable Data to send as the body of the SMS message. (160 characters maximum) Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 153 API frames Transmit (TX) Request: IPv4 - 0x20 Transmit (TX) Request: IPv4 - 0x20 Description A TX Request message causes the device to transmit data in IPv4 format. A TX request frame for a new destination creates a network socket. After the network socket is established, data from the network that is received on the socket is sent out the device's serial port in the form of a Receive (RX) Packet frame. Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Field name Field value Data type Description Frame type 0x20 Byte Frame ID Byte Reference identifier used to match status responses. 0 disables the TX Status frame. Destination address 32-bit big endian Destination port 16-bit big endian Source port 16-bit If the source port is 0, the device attempts to send the frame big endian data using an existing open socket with a destination that matches the destination address and destination port fields of this frame. If there is no matching socket, then the device attempts to open a new socket. If the source port is non-zero, the device attempts to send the frame data using an existing open socket with a source and destination that matches the source port, destination address, and destination port fields of this frame. If there is no matching socket, it returns an error. Protocol Byte 0 = UDP 1 = TCP 4 = SSL over TCP Transmit options Byte bitfield Bit fields are offset 0 Bit field 0 - 7. Bits 0, and 2-7 are reserved, bit 1 is not. BIT 1 = 1 - Terminate the TCP socket after transmission is complete 0 - Leave the socket open. Closed by timeout, see TM (IP Client Connection Timeout). Ignore this bit for UDP packets. All other bits are reserved and should be 0. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 154 API frames Field name Payload Transmit (TX) Request: IPv4 - 0x20 Field value Data type Description Variable Data to be transferred to the destination, may be up to 1500 bytes. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 155 API frames Tx Request with TLS Profile - 0x23 Tx Request with TLS Profile - 0x23 Description The frame gives greater control to the application over the TLS settings used for a connection. A TX Request with TLS Profile frame implies the use of TLS and behaves similar to the TX Request (0x20) frame, with the protocol field replaced with a TLS Profile field to choose from the profiles configured with the $0, $1, and $2 configuration commands. Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Field name Field value Data type Description Frame type 0x23 Byte Frame ID Byte Reference identifier used to match status responses. 0 disables the TX Status frame. Destination address 32-bit big endian Destination port 16-bit big endian Source port 16-bit If the source port is 0, the device attempts to send the frame big endian data using an existing open socket with a destination that matches the destination address and destination port fields of this frame. If there is no matching socket, then the device attempts to open a new socket. If the source port is non-zero, the device attempts to send the frame data using an existing open socket with a source and destination that matches the source port, destination address, and destination port fields of this frame. If there is no matching socket, the TX Status frame returns an error. TLS profile Byte Zero-indexed number that indicates the profile as specified by the corresponding $ command. Transmit options Byte bitfield Bit fields are offset 0 Bit field 0 - 7. Bits 0, and 2-7 are reserved, bit 1 is not. BIT 1 = 1 - Terminate the TCP socket after transmission is complete 0 - Leave the socket open. Closed by timeout, see TM (IP Client Connection Timeout). Ignore this bit for UDP packets. All other bits are reserved and should be 0. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 156 API frames Field name Payload Tx Request with TLS Profile - 0x23 Field value Data type Description Variable Data to be transferred to the destination, may be up to 1500 bytes. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 157 API frames AT Command Response - 0x88 AT Command Response - 0x88 Description A device sends this frame in response to an AT Command (0x08) frame. Some commands send back multiple frames. Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Field name Field Data value type Frame type 0x88 Description Byte Frame ID Byte Identifies the data frame for the host to correlate with a subsequent ACK. If set to 0, the device does not send a response. AT command Byte Command name: two ASCII characters that identify the AT command. Byte 0 = OK 1 = ERROR 2 = Invalid command 3 = Invalid parameter Byte Register data in binary format. If the register was set, then this field is not returned. Status Parameter value ## Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 158 API frames Transmit (TX) Status - 0x89 Transmit (TX) Status - 0x89 Description Indicates the success or failure of a transmit operation. Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Field name Field value Data type Description Frame type 0x89 Byte Frame ID Byte Refers to the frame ID specified in a previous transmit frame Status Byte Status code (see the table below) The following table shows the status codes. Code Description 0x0 Successful transmit 0x21 Failure to transmit to cell network 0x22 Not registered to cell network 0x2c Invalid frame values (check the phone number) 0x31 Internal error 0x32 Resource error (retry operation later) 0x74 Message too long 0x78 Invalid UDP port 0x79 Invalid TCP port 0x7A Invalid host address 0x7B Invalid data mode 0x80 Connection refused 0x81 Socket connection lost 0x82 No server 0x83 Socket closed Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 159 API frames Transmit (TX) Status - 0x89 Code Description 0x84 Unknown server 0x85 Unknown error 0x86 Invalid TLS configuration (missing file, and so forth) Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 160 API frames Modem Status - 0x8A Modem Status - 0x8A Description Cellular component status messages are sent from the device in response to specific conditions. Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Field name Field value Data type Frame type 0x8A Byte Status ## Byte Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide Description 0 = Hardware reset or power up 1 = Watchdog timer reset 2 = Registered with cellular network 3 = Unregistered with cellular network 0x0E = Remote Manager connected 0x0F = Remote Manager disconnected 161 API frames Receive (RX) Packet: SMS - 0x9F Receive (RX) Packet: SMS - 0x9F Description This XBee Smart Modem uses this frame when it receives an SMS message. Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Field name Field value Data type Frame Type 0x9F Byte Description Phone number 20 byte string String representation of the phone number, padded out with null bytes (0x0). Payload Variable Body of the received SMS message. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 162 API frames Receive (RX) Packet: IPv4 - 0xB0 Receive (RX) Packet: IPv4 - 0xB0 Description The XBee Smart Modem uses this frame when it receives RF data on a network socket that is created by a TX request frame or configuring C0 (Source Port). Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Frame data fields Offset Description Frame type 3 0xB0 IPv4 32-bit source address MSB 4 The address in the example below is for a source address of 192.168.0.104. 32-bit big endian. 5 6 7 16-bit destination port MSB 8 LSB 9 The port that the packet was received on. 16-bit big endian. 16-bit source port MSB 10 The port that the packet was sent from. 16-bit big endian. LSB 11 Protocol MSB 12 0 = UDP 1 = TCP 4 = SSL over TCP Status 13 Reserved Payload 14 Data received from the source. The maximum size is 1500 bytes. 15 16 17 18 Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 163 Configure the XBee Smart Modem using Digi Remote Manager Use Digi Remote Manager (https://remotemanager.digi.com/) to perform the operations in this section. Each operation requires that you enable Remote Manager with the DO command and that you connect the XBee Smart Modem to an access point that has an external Internet connection to allow access to Digi Remote Manager. Note Digi is consolidating our cloud services, Digi Device Cloud and Digi Remote Manager®, under the Remote Manager name. This phased process does not affect device functionality or the functionality of the web services and other features. However, customers will find that some user interface and firmware functionality mention both Device Cloud and Digi Remote Manager. Create a Remote Manager account Get the XBee Smart Modem IMEI number Add a XBee Smart Modem to Remote Manager Update the firmware Update the firmware using web services Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 165 165 165 166 166 164 Configure the XBee Smart Modem using Digi Remote Manager Create a Remote Manager account Create a Remote Manager account Digi Remote Manager is an on-demand service with no infrastructure requirements. Remote devices and enterprise business applications connect to Remote Manager through standards-based web services. This section describes how to configure and manage an XBee using Remote Manager. For detailed information on using Remote Manager, refer to the Remote Manager User Guide, available via the Documentation tab in Remote Manager. Before you can manage an XBee with Remote Manager, you must create a Remote Manager account. To create a Remote Manager account: 1. Go to https://www.digi.com/products/cloud/digi-remote-manager. 2. Click 30 DAY FREE TRIAL/LOGIN. 3. Follow the online instructions to complete account registration. You can upgrade your Developer account to a paid account at any time. When you are ready to deploy multiple XBee Smart Modems in the field, upgrade your account to access additional Remote Manager features. Get the XBee Smart Modem IMEI number Before adding an XBee to your Remote Manager account inventory, you need to determine the International Mobile Equipment Identity (IMEI) number for the device. Use XCTU to view the IMEI number by querying the IM parameter. Add a XBee Smart Modem to Remote Manager To add an XBee to your Remote Manager account inventory, follow these steps: Go to https://remotemanager.digi.com/. 1. Log in to your account. 2. Click Device Management > Devices. 3. Click Add Devices. The Add Devices dialog appears. 4. Select IMEI #, and type or paste the IMEI number of the XBee you want to add. The IM (IMEI) command provides this number. 5. Click Add to add the device. The XBee is added to your inventory. 6. Click OK to close the Add Devices dialog and return to the Devices view. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 165 Configure the XBee Smart Modem using Digi Remote Manager Update the firmware Update the firmware XBee Smart Modem supports Remote Manager firmware updates. To perform a firmware update: 1. Download the updated firmware file for your device from Digi's support site. This is a zip file containing .ebin and .mxi files for import. 2. Unzip the file. 3. In your Remote Manager account, click Device Management > Devices. 4. Select the first device you want to update. 5. To select multiple devices (must be of the same type), press the Control key and select additional devices. 6. Click More in the Devices toolbar and select Update Firmware from the Update category of the More menu. The Update Firmware dialog appears. 7. Click Browse to select the .ebin file that you unzipped earlier. 8. Click Update Firmware. The updated devices automatically reboot when the updates are complete. Update the firmware using web services Remote Manager supports both synchronous and asynchronous firmware update using web services. The following examples show how to perform an asynchronous firmware update. See the Remote Manager documentation for more details on firmware updates. Note You must use XCTU to update the cellular component's firmware. 1. Download the updated firmware file for your device from Digi's support site. This is a zip file containing .ebin and .mxi files for import. 2. Unzip the file and locate the .ebin inside the unzipped directory. 3. Send an HTTP SCI request to Remote Manager with the contents of the .ebin file converted to base64 data; see the following example. Example: update the XBee firmware synchronously with Python 3.0 import base64 import requests # Location of firmware image firmware_path = 'XBXC.ebin' # Remote Manager device ID of the device being updated device_id = '00010000-00000000-03526130-70153378' # Remote Manager username and password username = "my_Remote_manager_username" password = "my_remote_manager_password" url = 'https://remotemanager.digi.com/ws/sci' Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 166 Configure the XBee Smart Modem using Digi Remote Manager Update the firmware using web services # Get firmware image fw_file = open(firmware_path, 'rb') fw_data = fw_file.read() fw_data = base64.encodebytes(fw_data).decode('utf-8') # Form update_firmware request data = """ {} """.format(device_id, fw_data) # Post request r = requests.post(url, auth=(username, password), data=data) if (r.status_code != 200) or ("error" in r.content.decode('utf-8')): print("firmware update failed") else: print("firmware update success") Example: use the device's firmware image to update the XBee firmware synchronously To update the XBee firmware synchronously with Python 3.0, but using the device firmware image already uploaded to Remote Manager, upload the device's *.ebin firmware to Remote Manager: 1. Download the updated firmware file for your device from Digi's support site. This is a zip file containing .ebin and .mxi files for import. 2. Unzip the file and locate the .ebin inside the unzipped directory. 3. Log in to Remote Manager. 4. Click the Data Services tab. 5. Click Data Files. 6. Click Upload Files; browse and select the *.ebin firmware file to upload it. 7. Send an HTTP SCI request to Remote manager with the path of the .ebin file; see the example below. import base64 import requests # Location of firmware image on Remote Manager firmware_path = '~/XBXC.ebin' # Remote Manager device ID of the device being updated device_id = '00010000-00000000-03526130-70153378' # Remote Manager username and password username = "my_remote_manager_username" password = "my_remote_manager_password" Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 167 Configure the XBee Smart Modem using Digi Remote Manager Update the firmware using web services url = 'https://remotemanager.digi.com/ws/sci' # Form update_firmware request data = """ {} """.format(device_id, firmware_path) # Post request r = requests.post(url, auth=(username, password), data=data) if (r.status_code != 200) or ("error" in r.content.decode('utf-8')): print("firmware update failed") else: print("firmware update success") Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 168 Troubleshooting This section contains troubleshooting steps for the XBee Smart Modem. Cannot find the serial port for the device Correct a macOS Java error Unresponsive cellular component in Bypass mode Not on expected network after APN change Syntax error at line 1 Error Failed to send SMS Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 170 172 173 174 174 174 169 Troubleshooting Cannot find the serial port for the device Cannot find the serial port for the device Condition In XCTU, the serial port that your device is connected to does not appear. Solution 1. Click the Discover radio modules button . 2. Select all of the ports to be scanned. 3. Click Next and then Finish. A dialog notifies you of the devices discovered and their details. 4. Remove the development board from the USB port and view which port name no longer appears in the Discover radio devices list of ports. The port name that no longer appears is the correct port for the development board. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 170 Troubleshooting Cannot find the serial port for the device Other possible issues Other reasons that the XBee Smart Modem is not discoverable include: 1. If you accidentally have the loopback pins jumpered. 2. You may not have a driver installed. If you do not have a driver installed, the item will have an exclamation point icon next to it in the Windows Device Manager. 3. You may not be using an updated FTDI driver. a. Click here to download the drivers for your operating system. b. This may require you to reboot your computer. c. Disconnect the power and USB from the XBIB-U-DEV board and reconnect it. 4. If you have a driver installed and updated but still have issues, on Windows 10 you may have to enable VCP on the driver; see Enable Virtual COM port (VCP) on the driver. Enable Virtual COM port (VCP) on the driver On Windows 10 computers, if XCTU does not see the devices you have attached to a PC, you may need to enable VCP on the USB driver. To enable VCP: 1. Click the Search button. 2. Type Device Manager to search for it. 3. Click Universal Serial Bus controllers. 4. If it displays more than one USB controller, unplug the XBee Smart Modem and plug it back in to make sure you choose the correct one. 5. Right-click the USB controller and select Properties; a dialog displays. 6. Select the Advanced tab. 7. Check Load VCP. 8. Click OK. 9. Unplug the board and plug it back in. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 171 Troubleshooting Correct a macOS Java error Correct a macOS Java error When you use XCTU on macOS computer, you may encounter a Java error. Condition When opening XCTU for the first time on a macOS computer, you may see the following error: Solution 1. Click More info to open a browser window. 2. Click Download to get the file javaforosx.dmg. 3. Double-click on the downloaded javaforosx.dmg. 4. In the dialog, double-click the JavaForOSX.pkg and follow the instructions to install Java. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 172 Troubleshooting Unresponsive cellular component in Bypass mode Unresponsive cellular component in Bypass mode When in Bypass mode, the XBee Smart Modem does not automatically reset or reboot the cellular component if it becomes unresponsive. Condition In Bypass mode, the XBee Smart Modem does not respond to commands. Solution 1. Query the AI (Association Indication) parameter to determine whether the cellular component is connected to the XBee Smart Modem software. If AI is 0x2F, Bypass mode should work. If not, look at the status codes in AI (Association Indication) for guidance. 2. You can send the !R (Modem Reset) command to reset only the cellular component. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 173 Troubleshooting Not on expected network after APN change Not on expected network after APN change Condition The XBee Smart Modem is not on the expected network after a change to the AN (Access Point Name) command. Solution Send ATNR0 to reset Internet connectivity. See NR (Network Reset) for more information. Syntax error at line 1 You may get a syntax error at line 1 error after pasting example MicroPython code and pressing Ctrl+D. Solution This commonly happens when you accidentally type a character at the beginning of line 1 before pasting the code. Error Failed to send SMS In MicroPython, you consistently get Error Failed to send SMS messages. Solution Your device cannot connect to the cell network. The reason may be: 1. The antenna is improperly or loosely connected. 2. The device is at a location where cellular service cannot reach. If the device is connected to the network, the red LED blinks about twice in a second. If it is not connected it does not blink; see The Associate LED. 3. You SIM card is out of SMS text quota. 4. The device is not getting enough current, for example if power is being supplied only by USB to the XBIB development board, rather than using an additional external power supply. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 174 Regulatory information Modification statement Interference statement FCC Class B digital device notice RF exposure FCC-approved antennas Labeling requirements for the host device Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 176 176 176 177 177 178 175 Regulatory information Modification statement Modification statement Digi International has not approved any changes or modifications to this device by the user. Any changes or modifications could void the user’s authority to operate the equipment. Digi International n’approuve aucune modification apportée à l’appareil par l’utilisateur, quelle qu’en soit la nature. Tout changement ou modification peuvent annuler le droit d’utilisation de l’appareil par l’utilisateur. Interference statement This device complies with Part 15 of the FCC Rules and Industry Canada license-exempt RSS standard (s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. FCC Class B digital device notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: n Reorient or relocate the receiving antenna. n Increase the separation between the equipment and receiver. n Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. n Consult the dealer or an experienced radio/TV technician for help. IMPORTANT: The RF module has been certified for mobile and base radio applications. If the module will be used for portable applications, the device must undergo SAR testing. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Re-orient or relocate the receiving antenna, Increase the separation between the equipment and receiver, Connect equipment and receiver to outlets on different circuits, or Consult the dealer or an experienced radio/TV technician for help. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 176 Regulatory information RF exposure RF exposure CAUTION! This equipment is approved for mobile and base station transmitting devices only. Antenna(s) used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. ATTENTION! Cet équipement est approuvé pour la mobile et la station base dispositifs d'émission seulement. Antenne(s) utilisé pour cet émetteur doit être installé pour fournir une distance de séparation d'au moins 25 cm à partir de toutes les personnes et ne doit pas être situé ou fonctionner en conjonction avec tout autre antenne ou émetteur. FCC-approved antennas The can be installed using antennas and cables constructed with non-standard connectors (RPSMA, RPTNC, and so forth) An adapter cable may be necessary to attach the XBee connector to the antenna connector. The modules are FCC approved for fixed base station and mobile applications for the channels indicated in the tables below. If the antenna is mounted at least 25 cm from nearby persons, the application is considered a mobile application. The antennas below have been approved for use with this module. Digi does not carry all of these antenna variants. Contact Digi Sales for available antennas. Bluetooth antennas The following tables cover the antennas that are approved for use with the Bluetooth radio. Integral antenna Part number Type (description) Gain Application 31000020-01 Integral antenna -2.5 dBi Fixed/Mobile Dipole antennas Part number Type (description) Gain Application A24-HASM-450 Dipole (Half-wave articulated RPSMA-4.5") 2.1 dBi Fixed/Mobile A24-HABUF-P5I Dipole (Half-wave bulkhead mount U.FL w/ 5" pigtail) 2.0 dBi Fixed/Mobile A24-HASM-525 Dipole (Half-wave articulated RPSMA-5.25") 2.0 dBi Fixed/Mobile Flex PCB antennas Part number Type (description) Gain Application FXP74.07.0100A Flexible PCB, U.FL w/ 100mm pigtail 4.0 dBi Fixed/Mobile Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 177 Regulatory information Labeling requirements for the host device Cellular antennas Antenna gain must be below: Frequency band Gain Band 2 (1900 MHz) 9.70 dBi Band 4 (1700 MHz) 6.00 dBi Band 12 (700 MHz) 9.01 dBi Bande de fréquence Gain Band 2 (1900 MHz) 9.70 dBi Band 4 (1700 MHz) 6.00 dBi Band 12 (700 MHz) 9.01 dBi Labeling requirements for the host device The device shall be properly labeled to identify the product within the host device. The certification labels of the module shall be clearly visible at all times when installed in the host device, otherwise the host device must be labeled to display the FCC ID and IC of the module, preceded by the words "Contains transmitter module", or the word "Contains", or similar wording expressing the same meaning, as follows: Contains FCC ID: MCQ-XB3C1 Contains IC: 1846A-XB3C1 Contains FCC ID:RI7XE866A1NA Contains IC: 5131A-XE866A1NA L'appareil hôte doit être étiqueté comme il faut pour permettre l'identification des modules qui s'y trouvent. L'étiquettes de certification du module donné doit être posée sur l'appareil hôte à un endroit bien en vue en tout temps. En l'absence d'étiquette, l'appareil hôte doit porter une étiquette donnant le FCC ID et le IC du module, précédé des mots « Contient un module d'émission », du mot « Contient » ou d'une formulation similaire exprimant le même sens, comme suit: Contains FCC ID: MCQ-XB3C1 Contains IC: 1846A-XB3C1 Contains FCC ID:RI7XE866A1NA Contains IC: 5131A-XE866A1NA This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de classe B est conforme à la norme canadienne ICES-003. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 178

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 178
Page Mode                       : UseOutlines
Page Layout                     : SinglePage
Language                        : en-us
Producer                        : madbuild
Create Date                     : 2018:08:22 08:47:07-05:00
Modify Date                     : 2018:08:22 08:47:07-05:00
Title                           : Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
Author                          : Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
Subject                         : Digi XBee3 Cellular LTE Cat 1
Keywords                        : Digi, XBee3, Cellular, LTE, Cat, 1, Embedded, Modem
EXIF Metadata provided by EXIF.tools