INST AP 127 B040910 (APC Remote Accessory Wiring Diagram).qxp Duct Smoke Detector Accessories Installation Sheet
User Manual: Duct Smoke Detector
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Wiring: Dimensions: Sound Pressure: Power Requirements: LEDs/Horn Switches Single Gang Double Gang 78db @ 10 ft Alarm LED Trouble LED Pilot LED Alarm Horn 6” 24AWG Pigtails 6” 22AWG Pigtails 4½” (114.3mm)H x 2¾” (69.85mm)W 4½” (114.3mm)H x 4½” (114.3mm)W MS SERIES REMOTE ACCESSORIES 4.0A Class 4.0A Class 3.0A Class 3.0A Class I Power Supply I Power Supply II Power Supply II Power Supply 15mA @ 24VDC 15mA @ 24VDC 15mA @ 24VDC 20mA @ 24VDC Approvals: UL Listed for use with Air Products and Controls duct smoke detectors including all RW- Series, SM- Series and SL- Series duct smoke detectors UL URRQ.S7425 CSFM 7300-1004:107 MEA 73-92-E Vol.25 AVAILABLE ACCESSORIES FOR USE WITH AIR PRODUCTS DUCT SMOKE DETECTORS REMOTE ACCESSORIES MS-RA Remote Alarm MS-RA/R Remote Alarm, push button Test/Reset Switch MS-RA/P/R Remote Alarm, Pilot, push-button Test/Reset Switch MS-KA/R Remote Alarm, key-operated Test/Switch MS-KA/P/R Remote Alarm, Pilot, key-operated Test/Reset Switch MS-RA/P Remote Alarm, Pilot MS-RH Remote Alarm Horn MS-RH/KA/P/R Remote Alarm, Pilot, Horn, key-operated Test/Reset Switch MS-RH/P/A Remote Alarm, Pilot, Horn MS-RH/KA/P/A/T Remote Alarm, Trouble, Pilot, Horn, key-operated Test/Reset Switch MS-RA/P/T Remote Pilot, Trouble MS-RA/FT/P Remote Pilot, Trouble, push-button Test/Reset Switch MS-KA/P/R/T Remote Pilot, Trouble, key-operated Test/Reset Switch MS-RD Remote Alarm MS-F/T Remote Trouble SHP24-1575R Horn/Strobe, red housing, clear cover SHP24-1575O Horn/Strobe, white housing, opaque cover SHP24-1575W Horn/Strobe, white housing, clear cover NOTCHED SAMPLING TUBES (SL- SERIES) STN-1.0 For duct widths of 6” TO 1.0’ STN-2.5 For duct widths of 1.0’ TO 2.5’ STN-5.0 For duct widths of 2.5’ TO 5.0’ STN-10.0 For duct widths of 5.0’ TO 10.0’ SMOKE TEST GAS TG-1000 Solo Aerosol Test Gas with Spray Nozzle TG-2000 Solo Aerosol Test Gas with Nozzle for SL- Series Test Port SAMPLING TUBES (RW- AND SM- SERIES) STS-1.0 For duct widths of 6” TO 1.0’ STS-2.5 For duct widths of 1.0’ TO 2.5’ STS-5.0 For duct widths of 2.5’ TO 5.0’ STS-10.0 For duct widths of 5.0’ TO 10.0’ @ @ @ @ WEATHERPROOF ENCLOSURES WP-1 Weatherproof Enclosure for RW- and SM- Series Detectors WP-2000 Weatherproof Enclosure for SL- Series Detectors POWER SUPPLIES T-PB 202-1 24VAC T-PB 202-0 24VAC T-PB 303-1 24VAC T-PB 303-0 24VAC NOTICE: The information contained in this document is the most current available at the time of shipment of accompanying product, and is subject to change without notice. Future references should always be made to the most current revision of this document. The information contained in all this document should be considered before installing or using the product. Any example applications shown are subject to the most current enforced local/national codes, standards, approvals, certifications, and/or the authority having jurisdiction. All of these resources, as well as the specific manufacturer of any shown or mentioned related equipment, should be consulted prior to any implementation. For further information or assistance concerning this product, contact Air Products and Controls Inc. Air Products and Controls Inc. reserves the right to change any and all documentation without notice. © Air Products and Controls Inc. 2004 A COPY OF THESE INSTRUCTIONS SHOULD BE LEFT WITH THE EQUIPMENT UNTIL INSTALLATION BY ALL TRADES IS FULLY COMPLETE. FOLLOWING FINAL INSPECTION, A COPY SHOULD BE LEFT WITH THE OWNER/USER. * AIR PRODUCTS AND CONTROLS INC. INSTALLATION INSTRUCTIONS FOR DUCT SMOKE DETECTOR REMOTE ACCESSORIES 1749 East Highwood • Pontiac, MI 48340 USA • US Toll Free 888.332.2241 • Phone 248.332.3900 • Fax 248.332.8807 • www.ap-c.com NOTE: For proper installation, testing, operation and maintenance of a duct smoke detector, please refer to the detector installation guide. The following wiring diagrams are applicable only to compatible, current limited, UL Listed remote accessories from Air Products and Controls. Use of any other devices may result in damage to the duct smoke detector, potential injury, and will void any applicable warranties. SL-2000 Series Duct Smoke Detectors * NOTE: For remote accessories with a Trouble LED (yellow), a jumper wire must be placed between Terminals 20 and 15. The Trouble LED will illuminate when the detector cover is removed, or if the smoke detector head is removed and the cover replaced. Trouble contacts CANNOT be connected to a Fire Alarm Control Panel when using this option without the use of a slave relay. RED ALARM LED RED STROBE AND/OR HORN BLACK 2 19 RED PILOT BLACK GREEN PILOT LED 1 20 BLACK KEY OR PUSH BUTTON “TEST / RESET” SWITCH BLACK TEST / RESET 4 19 RED TROUBLE BLACK YELLOW TROUBLE LED 15 JUMPER 20 * NOTE: If duct smoke detectors are interconnected for common functions, please refer to unit installation guide for proper connection of remote alarm functions. 12 19 ALARM SM-501 Series Duct Smoke Detectors * NOTE: For remote accessories with a Trouble LED (yellow), a jumper wire must be placed between Terminals 14 and 18. The Trouble LED will illuminate when the smoke detector head is removed. Trouble contacts CANNOT be connected to a Fire Alarm Control Panel when using this option without the use of a slave relay. RED ALARM LED RED STROBE AND/OR HORN BLACK 21 19 RED PILOT BLACK GREEN PILOT LED 21 20 BLACK BLACK KEY OR PUSH BUTTON “TEST / RESET” SWITCH TEST / RESET 13 19 RED TROUBLE BLACK YELLOW TROUBLE LED 18 JUMPER 14 * NOTE: If duct smoke detectors are interconnected for common functions, please refer to unit installation guide for proper connection of remote alarm functions. 17 19 ALARM 2650-560APC and 2650-561APC Duct Smoke Detectors * NOTE: For remote accessories with a Trouble LED (yellow), a jumper wire must be placed between Terminals 20 and 13. The Trouble LED will illuminate when the smoke detector head is removed. Trouble contacts CANNOT be connected to a Fire Alarm Control Panel when using this option without the use of a slave relay. RED ALARM LED RED STROBE AND/OR HORN BLACK 19 20 RED PILOT BLACK GREEN PILOT LED 18 19 BLACK KEY OR PUSH BUTTON “TEST / RESET” SWITCH BLACK TEST / RESET 16 14 RED TROUBLE BLACK YELLOW TROUBLE LED 13 JUMPER 20 * NOTE: If duct smoke detectors are interconnected for common functions, please refer to unit installation guide for proper connection of remote alarm functions. 16 17 ALARM INST AP-127 B040913 RWJ Series Duct Smoke Detectors RWF Series Duct Smoke Detectors RWX Series Duct Smoke Detectors RWL Series Duct Smoke Detectors RWH Series Duct Smoke Detectors * NOTE: For RWJ Series duct smoke detectors, no jumper is required for remote accessory Trouble conenctions. A Trouble LED (yellow) connected to Terminals 13 and 20 will illuminate when the smoke detector is removed. If the trouble contacts of the RWJ Series detector are being used for other switching applications, or for connection to a Fire Alarm Control Panel, the on-board RWJ option jumper must be removed (cut). Failure to remove the RWJ option jumper could result in damage to the Fire Alarm Control Panel or other connected equipment. * NOTE: For connection of remote accessories with a Trouble LED (yellow) to the RWF Series, RWX Series, RWL Series and RWH Series, a jumper wire must be placed between Terminals 14 and 19. The Trouble LED will illuminate when the smoke detector head is removed. Trouble contacts CANNOT be connected to a Fire Alarm Control Panel when using this option without the use of a slave relay. RED ALARM LED RED STROBE AND/OR HORN BLACK 16 20 RED PILOT BLACK GREEN PILOT LED 16 17 BLACK BLACK KEY OR PUSH BUTTON “TEST / RESET” SWITCH TEST / RESET 13 RED BLACK TROUBLE 14 JUMPER* 19 *Jumper not required for RWJ Series Duct Smoke Detectors 20 YELLOW TROUBLE LED * NOTE: If duct smoke detectors are interconnected for common functions, please refer to unit installation guide for proper connection of remote alarm functions. 19 18 ALARM RW-UNI Series Duct Smoke Detectors * NOTE: For remote accessories with a Trouble LED (yellow), an SKD-115 jumper (available from Air Products and Controls Inc.) must be placed between Terminals 3 and 12. The Trouble LED will illuminate when the smoke detector head is removed. Trouble contacts CANNOT be connected to a Fire Alarm Control Panel when using this option without the use of a slave relay. RED ALARM LED RED STROBE AND/OR HORN BLACK 19 20 RED PILOT BLACK GREEN PILOT LED 16 18 BLACK KEY OR PUSH BUTTON “TEST / RESET” SWITCH BLACK TEST / RESET 13 20 RED 5 RED SKD-24 WHITE 12 TROUBLE @ 24VAC/DC BLACK YELLOW TROUBLE LED 13 RED BLACK 3 BLACK SKD-115 WHITE 12 TROUBLE @ 115VAC/DC 2 YELLOW TROUBLE LED * NOTE: If duct smoke detectors are interconnected for common functions, please refer to unit installation guide for proper connection of remote alarm functions. 16 17 ALARM RW-024 Series Duct Smoke Detectors * NOTE: For remote accessories with a Trouble LED (yellow), an SKD-24 jumper (available from Air Products and Controls Inc.) must be placed between Terminals 5 and 12. The Trouble LED will illuminate when the smoke detector head is removed. Trouble contacts CANNOT be connected to a Fire Alarm Control Panel when using this option without the use of a slave relay. RED ALARM LED RED STROBE AND/OR HORN BLACK 19 20 RED PILOT BLACK GREEN PILOT LED 16 18 BLACK KEY OR PUSH BUTTON “TEST / RESET” SWITCH BLACK TEST / RESET 13 20 RED 5 SKD-24 RED WHITE 12 INST AP-127 B040913 TROUBLE BLACK YELLOW TROUBLE LED * NOTE: If duct smoke detectors are interconnected for common functions, please refer to unit installation guide for proper connection of remote alarm functions. 16 17 ALARM 2 RW-230/24 Series Duct Smoke Detectors * NOTE: For remote accessories with a Trouble LED (yellow), an SKD-115 or SKD-24 jumper (available from Air Products and Controls Inc.) must be placed between Terminals 5 and 12. The Trouble LED will illuminate when the smoke detector head is removed. Trouble contacts CANNOT be connected to a Fire Alarm Control Panel when using this option without the use of a slave relay. RED ALARM LED RED STROBE AND/OR HORN BLACK 19 20 RED PILOT BLACK GREEN PILOT LED RED ALARM LED 16 18 BLACK BLACK KEY OR PUSH BUTTON “TEST / RESET” SWITCH TEST / RESET RED STROBE AND/OR HORN HORN BLACK 13 RED BLACK @ 24VAC/DC @ 230VAC 12 WHITE SKD-115 BLACK 3 OR 5 RED SKD-24 WHITE 12 TROUBLE A strobe cannot be used directly with this detector. 20 YELLOW TROUBLE LED * NOTE: If duct smoke detectors are interconnected for common functions, please refer to unit installation guide for proper connection of remote alarm functions. 16 17 ALARM RW-AA Series Duct Smoke Detectors 4 3 ALARM * NOTE: When alarm horn is connected, the sound pressure is weaker than usual. RW-AR Series Duct Smoke Detectors RW-ARL Series Duct Smoke Detectors RED ALARM LED ALARM RED STROBE AND/OR HORN BLACK RED STROBE AND/OR HORN BLACK 5 4 2 3 GREEN PILOT LED RED BLACK RED PILOT GREEN PILOT LED BLACK PILOT 4 6 BLACK BLACK KEY OR PUSH BUTTON “TEST / RESET” SWITCH BLACK KEY OR PUSH BUTTON “TEST / RESET” SWITCH BLACK TEST / RESET 2 4 TEST / RESET INST AP-127 B040913 * NOTE: Remote accessory terminals 4, 5 and 6 are not supervised, and the output voltage (24VDC) will be present when the duct detector is in the appropriate monitored condition. 5 6 RED ALARM LED RW-DC Series Duct Smoke Detectors 2 5 ALARM 3
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:06059de6-d09f-4898-9cc3-62a30715c4ed Producer : Acrobat Distiller 6.0.1 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2004:12:01 08:47:36-05:00 Create Date : 2004:09:15 05:59:03-04:00 Metadata Date : 2004:12:01 08:47:36-05:00 Document ID : uuid:a5a1543d-887a-4b90-b51d-0186fd58d17b Format : application/pdf Title : INST AP-127 B040910 (APC Remote Accessory Wiring Diagram).qxp Creator : jludwig Author : jludwigEXIF Metadata provided by EXIF.tools