Wiring:

Dimensions:

Sound Pressure:

Power Requirements:

LEDs/Horn
Switches

Single Gang
Double Gang

78db @ 10 ft

Alarm LED
Trouble LED
Pilot LED
Alarm Horn

6” 24AWG Pigtails
6” 22AWG Pigtails

4½” (114.3mm)H x 2¾” (69.85mm)W
4½” (114.3mm)H x 4½” (114.3mm)W

MS SERIES REMOTE ACCESSORIES

4.0A Class
4.0A Class
3.0A Class
3.0A Class

I Power Supply
I Power Supply
II Power Supply
II Power Supply

15mA @ 24VDC
15mA @ 24VDC
15mA @ 24VDC
20mA @ 24VDC

Approvals:

UL Listed for use with Air Products and Controls duct smoke
detectors including all RW- Series, SM- Series and SL- Series
duct smoke detectors
UL URRQ.S7425
CSFM 7300-1004:107
MEA 73-92-E Vol.25

AVAILABLE ACCESSORIES FOR USE WITH
AIR PRODUCTS DUCT SMOKE DETECTORS
REMOTE ACCESSORIES
MS-RA
Remote Alarm
MS-RA/R
Remote Alarm, push button Test/Reset Switch
MS-RA/P/R
Remote Alarm, Pilot, push-button Test/Reset Switch
MS-KA/R
Remote Alarm, key-operated Test/Switch
MS-KA/P/R
Remote Alarm, Pilot, key-operated Test/Reset Switch
MS-RA/P
Remote Alarm, Pilot
MS-RH
Remote Alarm Horn
MS-RH/KA/P/R
Remote Alarm, Pilot, Horn, key-operated Test/Reset Switch
MS-RH/P/A
Remote Alarm, Pilot, Horn
MS-RH/KA/P/A/T Remote Alarm, Trouble, Pilot, Horn, key-operated Test/Reset Switch
MS-RA/P/T
Remote Pilot, Trouble
MS-RA/FT/P
Remote Pilot, Trouble, push-button Test/Reset Switch
MS-KA/P/R/T
Remote Pilot, Trouble, key-operated Test/Reset Switch
MS-RD
Remote Alarm
MS-F/T
Remote Trouble
SHP24-1575R
Horn/Strobe, red housing, clear cover
SHP24-1575O
Horn/Strobe, white housing, opaque cover
SHP24-1575W
Horn/Strobe, white housing, clear cover

NOTCHED SAMPLING TUBES (SL- SERIES)
STN-1.0
For duct widths of 6” TO 1.0’
STN-2.5
For duct widths of 1.0’ TO 2.5’
STN-5.0
For duct widths of 2.5’ TO 5.0’
STN-10.0
For duct widths of 5.0’ TO 10.0’

SMOKE TEST GAS
TG-1000
Solo Aerosol Test Gas with Spray Nozzle
TG-2000
Solo Aerosol Test Gas with Nozzle for SL- Series Test Port
SAMPLING TUBES (RW- AND SM- SERIES)
STS-1.0
For duct widths of 6” TO 1.0’
STS-2.5
For duct widths of 1.0’ TO 2.5’
STS-5.0
For duct widths of 2.5’ TO 5.0’
STS-10.0
For duct widths of 5.0’ TO 10.0’

@
@
@
@

WEATHERPROOF ENCLOSURES
WP-1
Weatherproof Enclosure for RW- and SM- Series Detectors
WP-2000
Weatherproof Enclosure for SL- Series Detectors
POWER SUPPLIES
T-PB 202-1
24VAC
T-PB 202-0
24VAC
T-PB 303-1
24VAC
T-PB 303-0
24VAC

NOTICE: The information contained in this document is the most current available at the time of shipment of accompanying product, and is subject to change without notice. Future references should always be made
to the most current revision of this document. The information contained in all this document should be considered before installing or using the product. Any example applications shown are subject to the most current enforced local/national codes, standards, approvals, certifications, and/or the authority having jurisdiction. All of these resources, as well as the specific manufacturer of any shown or mentioned related equipment,
should be consulted prior to any implementation. For further information or assistance concerning this product, contact Air Products and Controls Inc. Air Products and Controls Inc. reserves the right to change any and
all documentation without notice.
© Air Products and Controls Inc. 2004

A COPY OF THESE INSTRUCTIONS SHOULD BE LEFT WITH THE EQUIPMENT UNTIL INSTALLATION BY ALL TRADES IS FULLY COMPLETE.
FOLLOWING FINAL INSPECTION, A COPY SHOULD BE LEFT WITH THE OWNER/USER.

*

AIR PRODUCTS AND CONTROLS INC.
INSTALLATION INSTRUCTIONS FOR DUCT SMOKE DETECTOR
REMOTE ACCESSORIES

1749 East Highwood • Pontiac, MI 48340 USA • US Toll Free 888.332.2241 • Phone 248.332.3900 • Fax 248.332.8807 • www.ap-c.com

NOTE: For proper installation, testing, operation and maintenance of a duct smoke detector, please refer to the detector installation guide. The
following wiring diagrams are applicable only to compatible, current limited, UL Listed remote accessories from Air Products and Controls. Use of
any other devices may result in damage to the duct smoke detector, potential injury, and will void any applicable warranties.

SL-2000 Series Duct Smoke Detectors

* NOTE: For remote accessories with a Trouble LED (yellow), a jumper wire must be placed between Terminals 20 and 15. The Trouble LED will
illuminate when the detector cover is removed, or if the smoke detector head is removed and the cover replaced. Trouble contacts CANNOT be
connected to a Fire Alarm Control Panel when using this option without the use of a slave relay.

RED
ALARM
LED

RED
STROBE
AND/OR
HORN
BLACK

2

19

RED

PILOT

BLACK

GREEN
PILOT
LED

1

20

BLACK

KEY OR
PUSH BUTTON
“TEST / RESET”
SWITCH

BLACK

TEST / RESET

4

19

RED

TROUBLE

BLACK

YELLOW
TROUBLE
LED

15

JUMPER

20

* NOTE: If duct smoke detectors are interconnected for common functions, please refer to unit installation guide for proper connection of remote
alarm functions.
12
19
ALARM

SM-501 Series Duct Smoke Detectors

* NOTE: For remote accessories with a Trouble LED (yellow), a jumper wire must be placed between Terminals 14 and 18. The Trouble LED will
illuminate when the smoke detector head is removed. Trouble contacts CANNOT be connected to a Fire Alarm Control Panel when using this option
without the use of a slave relay.

RED
ALARM
LED

RED
STROBE
AND/OR
HORN
BLACK

21

19

RED

PILOT

BLACK

GREEN
PILOT
LED

21

20

BLACK

BLACK

KEY OR
PUSH BUTTON
“TEST / RESET”
SWITCH

TEST / RESET

13

19

RED

TROUBLE

BLACK

YELLOW
TROUBLE
LED

18

JUMPER

14

* NOTE: If duct smoke detectors are interconnected for common functions, please refer to unit installation guide for proper connection of remote
alarm functions.
17
19
ALARM

2650-560APC and 2650-561APC Duct Smoke Detectors

* NOTE: For remote accessories with a Trouble LED (yellow), a jumper wire must be placed between Terminals 20 and 13. The Trouble LED will
illuminate when the smoke detector head is removed. Trouble contacts CANNOT be connected to a Fire Alarm Control Panel when using this option
without the use of a slave relay.

RED
ALARM
LED

RED
STROBE
AND/OR
HORN
BLACK

19

20

RED

PILOT

BLACK

GREEN
PILOT
LED

18

19

BLACK

KEY OR
PUSH BUTTON
“TEST / RESET”
SWITCH

BLACK

TEST / RESET

16

14

RED

TROUBLE

BLACK

YELLOW
TROUBLE
LED

13

JUMPER

20

* NOTE: If duct smoke detectors are interconnected for common functions, please refer to unit installation guide for proper connection of remote
alarm functions.
16
17
ALARM

INST AP-127 B040913

RWJ Series Duct Smoke Detectors
RWF Series Duct Smoke Detectors
RWX Series Duct Smoke Detectors
RWL Series Duct Smoke Detectors
RWH Series Duct Smoke Detectors
* NOTE: For RWJ Series duct smoke detectors, no jumper is required for remote accessory Trouble conenctions. A Trouble LED (yellow) connected to Terminals 13 and 20 will illuminate when the smoke detector is removed. If the trouble contacts of the RWJ Series detector are being used
for other switching applications, or for connection to a Fire Alarm Control Panel, the on-board RWJ option jumper must be removed (cut). Failure to
remove the RWJ option jumper could result in damage to the Fire Alarm Control Panel or other connected equipment.
* NOTE: For connection of remote accessories with a Trouble LED (yellow) to the RWF Series, RWX Series, RWL Series and RWH Series, a
jumper wire must be placed between Terminals 14 and 19. The Trouble LED will illuminate when the smoke detector head is removed. Trouble
contacts CANNOT be connected to a Fire Alarm Control Panel when using this option without the use of a slave relay.

RED
ALARM
LED

RED
STROBE
AND/OR
HORN
BLACK

16
20

RED

PILOT

BLACK

GREEN
PILOT
LED

16
17

BLACK

BLACK

KEY OR
PUSH BUTTON
“TEST / RESET”
SWITCH

TEST / RESET

13

RED

BLACK

TROUBLE

14
JUMPER*

19

*Jumper not required for RWJ
Series Duct Smoke Detectors

20

YELLOW
TROUBLE
LED

* NOTE: If duct smoke detectors are interconnected for common functions, please refer to unit installation guide for proper connection of remote
alarm functions.

19
18
ALARM

RW-UNI Series Duct Smoke Detectors
* NOTE: For remote accessories with a Trouble LED (yellow), an SKD-115 jumper (available from Air Products and Controls Inc.) must be placed
between Terminals 3 and 12. The Trouble LED will illuminate when the smoke detector head is removed. Trouble contacts CANNOT be connected to a Fire Alarm Control Panel when using this option without the use of a slave relay.

RED
ALARM
LED

RED
STROBE
AND/OR
HORN
BLACK

19
20

RED

PILOT

BLACK

GREEN
PILOT
LED

16
18

BLACK
KEY OR
PUSH BUTTON
“TEST / RESET”
SWITCH
BLACK

TEST / RESET

13

20

RED

5
RED

SKD-24
WHITE

12
TROUBLE @ 24VAC/DC

BLACK

YELLOW
TROUBLE
LED

13

RED

BLACK

3
BLACK

SKD-115
WHITE

12
TROUBLE @ 115VAC/DC

2

YELLOW
TROUBLE
LED

* NOTE: If duct smoke detectors are interconnected for common functions, please refer to unit installation guide for proper connection of remote
alarm functions.
16
17
ALARM

RW-024 Series Duct Smoke Detectors
* NOTE: For remote accessories with a Trouble LED (yellow), an SKD-24 jumper (available from Air Products and Controls Inc.) must be placed
between Terminals 5 and 12. The Trouble LED will illuminate when the smoke detector head is removed. Trouble contacts CANNOT be connected to a Fire Alarm Control Panel when using this option without the use of a slave relay.

RED
ALARM
LED

RED
STROBE
AND/OR
HORN
BLACK

19
20

RED

PILOT

BLACK

GREEN
PILOT
LED

16
18

BLACK
KEY OR
PUSH BUTTON
“TEST / RESET”
SWITCH
BLACK

TEST / RESET

13

20

RED

5
SKD-24

RED

WHITE

12

INST AP-127 B040913

TROUBLE

BLACK

YELLOW
TROUBLE
LED

* NOTE: If duct smoke detectors are interconnected for common functions, please refer to unit installation guide for proper connection of remote
alarm functions.
16
17
ALARM

2

RW-230/24 Series Duct Smoke Detectors

* NOTE: For remote accessories with a Trouble LED (yellow), an SKD-115 or SKD-24 jumper (available from Air Products and Controls Inc.) must
be placed between Terminals 5 and 12. The Trouble LED will illuminate when the smoke detector head is removed. Trouble contacts CANNOT be
connected to a Fire Alarm Control Panel when using this option without the use of a slave relay.

RED
ALARM
LED

RED
STROBE
AND/OR
HORN
BLACK

19

20

RED

PILOT

BLACK

GREEN
PILOT
LED

RED
ALARM
LED

16

18

BLACK

BLACK

KEY OR
PUSH BUTTON
“TEST / RESET”
SWITCH

TEST / RESET

RED

STROBE
AND/OR
HORN
HORN

BLACK

13

RED

BLACK

@ 24VAC/DC

@ 230VAC

12

WHITE

SKD-115

BLACK

3

OR

5

RED

SKD-24

WHITE

12

TROUBLE

A strobe cannot be used directly with this detector.

20

YELLOW
TROUBLE
LED

* NOTE: If duct smoke detectors are interconnected for common functions, please refer to unit installation guide for proper connection of remote
alarm functions.
16
17
ALARM

RW-AA Series Duct Smoke Detectors

4

3

ALARM

* NOTE: When alarm horn is connected, the sound pressure is weaker than usual.

RW-AR Series Duct Smoke Detectors
RW-ARL Series Duct Smoke Detectors

RED
ALARM
LED

ALARM

RED

STROBE
AND/OR
HORN

BLACK

RED

STROBE
AND/OR
HORN

BLACK

5

4

2

3

GREEN
PILOT
LED

RED

BLACK

RED

PILOT

GREEN
PILOT
LED

BLACK

PILOT

4

6

BLACK

BLACK

KEY OR
PUSH BUTTON
“TEST / RESET”
SWITCH

BLACK

KEY OR
PUSH BUTTON
“TEST / RESET”
SWITCH

BLACK

TEST / RESET

2

4

TEST / RESET

INST AP-127 B040913

* NOTE: Remote accessory terminals 4, 5 and 6 are not supervised, and the output voltage (24VDC) will be present when the duct detector is in
the appropriate monitored condition.
5
6

RED
ALARM
LED

RW-DC Series Duct Smoke Detectors
2
5
ALARM

3



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Page Count                      : 2
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:06059de6-d09f-4898-9cc3-62a30715c4ed
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2004:12:01 08:47:36-05:00
Create Date                     : 2004:09:15 05:59:03-04:00
Metadata Date                   : 2004:12:01 08:47:36-05:00
Document ID                     : uuid:a5a1543d-887a-4b90-b51d-0186fd58d17b
Format                          : application/pdf
Title                           : INST AP-127 B040910 (APC Remote Accessory Wiring Diagram).qxp
Creator                         : jludwig
Author                          : jludwig
EXIF Metadata provided by EXIF.tools

Navigation menu