The world’s best-selling electric floor heating brand ™

SPEEDFIT-TEE
INSTALLATION INSTRUCTIONS

DESCRIPTION
The WARMUP Low-Profile Speedfit Tee Kit is suitable for use with
Warmup NAMSR self-regulating cable.

APPLICATION
The Speedfit-Tee is used to create a “T” connection with 3 selfregulating cables. This application is found on tracing runs for
water lines as well as a replacement for downspout runs in roof
and gutter applications. These connection kits must be installed
according to NAMSR guidelines and minimum installation
temperatures.

APPROVALS

KIT CONTENT
Item

Qty

Description

A

1

Main Box

B
C
D
E
F

3
3
2
2
1

Pressure Seal End
Grommets
Gaskets for Main Box
Cover for Main Box
Label

WARNING
The components are electrical devices. They must be installed
correctly to ensure proper operation and to prevent shock or fire.
Carefully follow all of the installation instructions and read these
important warnings.
•
To minimize the danger of fire from sustained electrical arcing
if the heating cable is damaged or improperly installed, and
to comply with the requirements of the national electrical
codes, ground-fault equipment protection must be used on
each heating cable branch circuit. Arcing may not be stopped by
conventional circuit protection.
•
Bus wires will short if they contact each other. Keep bus
wire separated.
•
Keep ends of heating cable and kit components dry before and
during installation.
•
The black heating cable core is conductive and can short. It must
be properly insulated and kept dry.

WARMUP INC.
USA: us@warmup.com
Tel.: 1-888-927-6333
www.warmup.com

•
•
•
•
•
•

Component approvals and performance are based on the use
of specified parts only. Do not substituted parts or use
vinyl electrical tape.
Leave these installation instructions with the user for future
reference.
The heating cable should not be embedded in the thermal
insulation.
The cable should not be twisted during installation.
De-energize all power circuits before installation or servicing.
The conductive layer of this heating cable device must be
connected to a suitable grounding/earthing terminal.

Caution:
Charring or burning the heat-shrinkable tubes in this kit will produce
fumes that may cause eye,shin, nose and throat irritation.

CANADA: ca@warmup.com
Tel.: 1-888-592-7687
www.warmup.ca

The world’s best-selling electric floor heating brand ™

The world’s best-selling electric floor heating brand ™

SPEEDFIT-TEE
INSTALLATION INSTRUCTIONS
PTC Cores
Outer jacket
Copper Braid

INSTALLATION INSTRUCTIONS

Outer jacket

Insulation
Bus wires

Cable with outer jacket for dry and wet conditions

1- Leave extra wire for connections
and mishaps.

4• Push the braid back to create a
bump.
• Then use a screwdriver or
similar to create an opening and
slide the inner cable out of the
braided ground mesh.
• Do not cut the ground braid.

7- Separate bus wires from the solid
carbon center and peel them off.

2- Insert the Pressure Seal End first
and then the grommet for each
cable.

5- Now expose the inner core
cables and carbon matrix by
carefully removing the inner jacket.
Do not cut the conductor cables.
3• Do not cut the braiding.
• Strip the outer jacket.
• Slightly bend the cable where
you made the cut to strip it.
•
•
•
•
•
•

WARMUP INC.
USA: us@warmup.com
Tel.: 1-888-927-6333
www.warmup.com

8- Clear about 3-4” of the inner wires
from the carbon matrix, then cut off
the excess matrix in between. You
should be left with a twisted ground
braid, and two inner conductor
cables about 3-4” long.

6- Twist the ground braid clean
for future connection to screw
connector.

CANADA: ca@warmup.com
Tel.: 1-888-592-7687
www.warmup.ca

The world’s best-selling electric floor heating brand ™

The world’s best-selling electric floor heating brand ™

SPEEDFIT-TEE
INSTALLATION INSTRUCTIONS

9• Using the glass cloth tape, put the ponytail brain against the inner jacket and do a minimum of 3 loops around
the inner jacket.
• Separate from the cable and loop a minimum of two times around the braid.
• Install the grommet to the edge of the loop tape. Do not install grommet over the tape.

10• Install wire number 3 in the
main box.
• Install the grommet into the
hole of the main box.
• Push pressure seal end and then
tight crews back into the main
box.

11• Loosen the screw number 3.
• Install wire number 3 on its
base.
• Tighten the screw back into
position.
• Cut all extra wire and braid.

WARMUP INC.
USA: us@warmup.com
Tel.: 1-888-927-6333
www.warmup.com

12• Install the wires number 1&2 in
the main box.
• Install the grommet into the
hole of the main box.
• Push pressure seal end and then
tight crews back into the main
box.

13• Loosen the screws number 1&2.
• Install wire number 1&2 on their
base.
• Tighten the screw back into
position.
• Cut all extra wire and braid.

14• Install the 2 gaskets and the 2
covers onto the main box.
• Tighten the screw back into
position

15• Affix the Low-Profile Tee
Connection and side wires to the
pipe using tape.
• Affix insulation.
• Install label on the of the
insulation protector.
• Give instructions to the owner/
user.

CANADA: ca@warmup.com
Tel.: 1-888-592-7687
www.warmup.ca

The world’s best-selling electric floor heating brand ™



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2016:02:24 14:29:40-05:00
Metadata Date                   : 2016:02:24 14:29:41-05:00
Modify Date                     : 2016:02:24 14:29:41-05:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:c58c78f8-4161-48e8-8fda-80cf677a16a1
Original Document ID            : xmp.did:4031EE556476E51195C3B11B0B6A23A0
Document ID                     : xmp.id:12FF6CEC2CDBE511BBF8951271E6FF12
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:11FF6CEC2CDBE511BBF8951271E6FF12
Derived From Document ID        : xmp.did:C5495DFD72CBE5119962E5B26B2DB22B
Derived From Original Document ID: xmp.did:4031EE556476E51195C3B11B0B6A23A0
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2016:02:24 14:29:40-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 3
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu