TRENDware TEW-231BRP EMC TEST REPORT Report No: C51ET385 Test Report ------------------------------------------------------------------------------- 1/45 Report No. C51ET385 Specifications ETSI EN 301 489-1 V1.4.1 (August, 2002) ETSI EN 301 489-17 V1.2.1 (April, 2002) Applicant TRENDware International Inc. Applicant address 3135 Kashiwa Street Torrance, CA 90505, USA Items tested Model No. IEEE 802.11b Wireless LAN Broadband Router TEW-231BRP Results Compliance (As detailed within this report) Date 11/20/2003 (month / day / year) (Sample received) 11/24/2003 (month / day / year) (Test) Prepared by ______________________ Authorized by Issue date December 10, 2003 Project Engineer (Jack Tsai) General Manager (Frank Tsai) (month / day / year) Modifications Tested by None Training Research Co., Ltd. Office at No. 255, Nan Yang Street, Shijr City, Taipei Hsien 221, Taiwan Laboratory at 1F, No. 255, Nan Yang Street, Shijr City, Taipei Hsien 221, Taiwan Open site at No. 15, Lane 530, Balian Rd., Sec. 1, Shijr City, Taipei Hsien 221, Taiwan Conditions of issue: This test report shall not be reproduced except in full, without written approval of TRC. And the test result contained within this report only relate to the sample submitted for testing. Ϫʳ Aut. No. ELA 131 Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 2/45 Generally Statement: The results appear in the following order: Electromagnetic compatibility and radio spectrum matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common Technical requirements Part 17:Specific conditions for Wideband data and HIPERLAN equipment. The results exhibits below only apply to particular samples tested and to the specific tests carried out, as detailed in this Test Report. The issue of this Test Report does not indicate any measure of Approval, Certification, Supervision, Control or Surveillance by Training Research Co., Ltd. of any product. No extract, abridgement or abstraction from a Test Report may be published or used to advertise a product without the written consent of the Director, Training Research Co., Ltd. who reserves the absolute right to agree or reject all or any of the details of any item of publicity for which consent may be sought. Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 3/45 Contents CHAPTER 0 EMISSION AND SUSCEPTIBILITY STANDARDS........5 EMISSION STANDARDS.......................................................... 5 SUSCEPTIBILITY STANDARDS.................................................................... 5 CHAPTER 1 INTRODUCTION..............................................................6 DESCRIPTION OF EUT............................................................................... 6 TEST M ETHOD .......................................................................................... 6 LIST OF SUPPORT EQUIPMENT ................................................................... 7 CHAPTER 2 EMISSION AND IMMUNITY REQUIREMENTS OVERVIEW....................................................................10 EMISSION (ETSI EN 301 489-1)............................................................. 10 IMMUNITY (ETSI EN 301 489-1)............................................................ 11 CHAPTER 3 PERFORMANCE CRITERIA.........................................12 ETSI EN 301 489-17, SUBCLAUSE 6.2 ................................................... 12 CHAPTER 4 ELECTROSTATIC DISCHARGES IMMUNITY TEST 18 ESD TEST INFORMATION:....................................................................... 18 EN 61000-4-2 PHOTO OF TEST SET-UP............................................ 20 CHAPTER 5 RADIO FREQUENCY IMMUNITY TEST (RS).............21 RS TEST INFORMATION:.......................................................................... 21 EN 61000-4-3 PHOTO OF TEST SET-UP............................................ 23 CHAPTER 6 ELECTRIC FAST TRANSIENT/ BURST REQUIREMENTS TEST ..................................24 EFT TEST INFORMATION: ....................................................................... 24 EN 61000-4-4 PHOTO OF TEST SET-UP............................................ 26 CHAPTER 7 SURGE IMMUNITY TEST.............................................27 SURGE TEST INFORMATION:.................................................................... 27 EN 61000-4-5 PHOTO OF TEST SET-UP............................................ 29 Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 4/45 CHAPTER 8 CONTINUOUS WAVE VOLTAGE IMMUNITY TEST 30 CS TEST INFORMATION:.......................................................................... 30 TEST INSTRUMENTS: ............................................................................... 32 EN 61000-4-6 PHOTO OF TEST SET-UP............................................ 33 CHAPTER 9 VOLTAGE DIP / INTERRUPTION TEST .....................34 DIP TEST INFORMATION:........................................................................ 34 EN 61000-4-11 PHOTO OF TEST SET-UP.......................................... 35 CHAPTER 10 HARMONICS TEST........................................................36 CHAPTER 11 VOLTAGE FLUCTUATION AND FLICKER TEST.....37 CHAPTER 12 CONDUCTED EMISSION TEST....................................38 TEST CONDITION AND SETUP ................................................................... 38 LIST OF TEST INSTRUMENT ..................................................................... 38 CONDUCTED TEST P LACEMENT (FRONT VIEW AND SIDE VIEW ).............. 39 TEST RESULT OF CONDUCTED EMISSIONS FOR M AINS POWER................ 40 CHAPTER 13 RADIATED EMISSION TEST........................................42 TEST CONDITION AND SETUP ................................................................... 42 LIST OF TEST INSTRUMENT ..................................................................... 42 RADIATED TEST P LACEMENT (FRONT VIEW AND SIDE VIEW ) ................. 43 TEST RESULT OF SPURIOUS RADIATED EMISSIONS ................................. 44 APPENDIX A .........................................................................................45 BRAND NAME AND M ODEL NAME LIST ................................................... 45 Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 5/45 Chapter 0 Emission and Susceptibility Standards Emission Standards Emission Standard European Standard International Standard ( ) EN 61000-6-3/2001 IEC 61000-6-3/1996 ( ) EN 61000-6-4/2001 IEC 61000-6-4/1997 ( ) EN 50081-1/1992 ( ) EN 50081-1/8.93 ( ) EN 55014/4.93 CISPR 14: 1993 ( ) EN 55015/12.93 CISPR 15: 1992 ( ) EN 55011/91 CISPR 11: 1990 ( X) EN 55022/98 ( X) EN 61000-3-2/2000 CISPR 22: 1997 IEC 61000-3-2: 2000 (Modified) ( X) EN 61000-3-3/1995 IEC 61000-3-3: 1994 + A1/2001 Susceptibility Standards Susceptibility Standard European Standard International Standard ( ) EN 61000-6-1/2001 IEC 61000-6-1/1997 ( ) EN 61000-6-2/2001 IEC 61000-6-2/1999 ( ) EN 50082-1/1997 ( ) EN 50082-2/1994 ( ) EN 55024/1998 CISPR 24/1997 ( ) EN 55020/2002 CISPR 20/2002 (X) EN 61000-4-2:1995 IEC 61000-4-2:1995 (X) EN 61000-4-3:1996 IEC 61000-4-3:1995 (X) EN 61000-4-4:1995 IEC 61000-4-4:1995 (X) EN 61000-4-5:1995 IEC 61000-4-5:1995 (X) EN 61000-4-6:1996 IEC 61000-4-6:1996 ( EN 61000-4-8:1993 IEC 61000-4-8:1993 (X) EN 61000-4-11:1994 IEC 61000-4-11:1994 ( EN 55014-2:1993 CISPR/F (Sec) 159 ) ) Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 6/45 Chapter 1 Introduction Description of EUT Product Name : IEEE 802.11b Wireless LAN Broadband Router Model : as Appendix A Frequency Range : 2.400GHz ~ 2.4835GHz Operating Frequency : 2.412GHz ~ 2.472GHz Support Channel : 13 Channels Modulation Skill : DBPSK, DQPSK, CCK Power Type : Power adapter Model: 48075100-C5 I/P: 230VAC, 50Hz, 90mA O/P: 7.5 VDC, 1000mA Power cable 184cm length, non-shielded, no ferrite core Data Cable : RJ45*1, 30m length, non-shielded, no ferrite core RJ45*3, 2m length, non-shielded, no ferrite core RJ45*1, 1.2m length, non-shielded, no ferrite core Test Method 1. Using the computer and software provided by the manufacturer to control EUT. 2. During test, making EUT to the following mode. (a) EMI testing: Making EUT to the linking mode with support equipments (b) EMS testing: Making EUT to the linking mode with support equipments Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 7/45 List of Support Equipment In order to construct the minimum testing, following equipment were used as the support units. Notebook Model No. : : IBM Think Pad X20 2662-11T Serial No. : FX-1192200/09 FCC ID ᛀ : : N/A, Do C Approved (Declaration of Confirmation) Approved 3892B565 Adaptor Model No. Serial No. FCC ID Power type Power cord : : : : : : IBM PA2450U 02K6654 N/A, Do C Approved I/P: 100 ~ 240vac, 50 ~ 60 Hz, 0.5A ~ 1.2A; O/P: 16Vdc, 4.5A Non-shielded, 1.80m long, Plastic, with ferrite core PC Model No. Serial No. FCC ID ᛀ : : : : : IBM 6840; HP Pavilion 6840MJV; P8574A 96CC 0C1; TW21920435 N/A, Do C 3892I279; 3902H097 Power type Power cord : : 100 ~ 127VAC / 4A, 200 ~ 240VAC/2A, 50 ~ 60Hz, 5A, Switching Non-shielded, 2.33 m length, Plastic hood, No ferrite core Printer Model No. Serial No. FCC ID ᛀ : : : : : HP C6464A, C2642A TH16LEB5PK, SG69A196GV None (DoC Approved), B94C2642X Power type Power cord : : Data cable : Switching adaptor Non-shielded, 173cm length, No ferrite core (between adaptor and AC source) Non-shielded, 180cm length, with ferrite core (between printer and adaptor) Shielded, 1.70m length, No ferrite core 3892H381, None Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 8/45 Monitor : HP 15’ Color Monitor, HP pavilion mx70 Model No. Serial No. : : D2827A, P1283A KR91379759, TWTBQ00397 FCC ID ᛀ : : C5F7NFCMC1518X 3872B039 Power type : 110 ~ 240 VAC / 50 ~ 60 Hz, Switching Power cord Data cable : : Shielded, 1.83m length, No ferrite core Shielded, 1.46m length, with two ferrite cores Modem Model No. FCC ID Power type Power cord Data cable : : : : : : ACEEX XDM-56V14 IFAXDM-56V14 Linear Non-shielded, 1.9m length, No ferrite cord RS232, Shielded, 1.2m length, No ferrite core RJ11C x 2, 7’ length non-shielded, No ferrite core Mouse Model No. Serial No. FCC ID ᛀ : : : : : HP M-S34 LZB90714106, LZC84446151 DZL211029 4862A011 Power type Power cord : : By PC Non-shielded, 1.88m length, No ferrite core Keyboard Model No. Serial No. : : : HP 5187-0343, SK-2501K BE21700404, M981216213 FCC ID ᛀ : : DoC Approved, GYUR38SK 3892C981, 3862A621 Power type Data cable : : By PC Shielded, 1.73m length, Plastic hood, No ferrite core Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 9/45 USB Gamepad : Rockfire Model No. Serial No. : : QF-337uv 10600545, KR91379759 FCC ID ᛀ : : None (CE approval) 3862A574 Power type : By computer Data Cable : Shielded, 1.81m long, Plastic, with ferrite core Notebook Model No. Serial No. FCC ID BSMI Power type Adaptor of PC Model No. Serial No. FCC ID ᛀ : : : : : : : : : : : ASUSTek Computer AB00F 24NP016361 DoC Approved 41016012 100 ~ 240VAC, 1A 50/60 Hz, Switching LITE-ON Electronics, Inc. PA-1530-01 00151184 DoC Approved 3882B259 Power cable : Power cable : Non-shielded, 1.72m length, Plastic hood, No ferrite core (Between power adaptor and AC power source) Shielded, 1.48m length, Plastic hood, with ferrite core (Between power adaptor and notebook) WLAN Card Model No. FCC ID : : : Gemtek Technology Co., Ltd. C911003 MXF-C911003 LAN Card Model No. Serial No. FCC ID Power type : : : : : D-Link DFE-530TX 0050BAE32FF3, 0050BAE3158B N/A, DoC Approved Powered by PC Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 10/45 Chapter 2 Emission and Immunity Requirements Overview Emission (ETSI EN 301 489-1) Phenomenon Application Equipment test requirement Radio and Radio and Radio and ancillary ancillary ancillary equipment for fixed use (base equipment for vehicular use equipment for portable use station (mobile (portable equipment) Applicable for stand alone testing Radiated emission Enclosure of ancillary equipment Conducted emission DC power input/output port Applicable Conducted emission AC mains input/output port AC mains input port Harmonic current emissions Voltage fluctuations and flicker AC mains input port equipment) equipment) Applicable for Applicable for stand alone stand alone testing testing Applicable Reference Subclause in the present document 8.2 Not applicable 8.3 Applicable Not applicable Not applicable 8.4 Applicable Not applicable Not applicable 8.5 Applicable Not applicable Not applicable 8.6 Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 11/45 Immunity (ETSI EN 301 489-1) Phenomenon Application Equipment test requirement Radio and Radio and Radio and Reference Subclause in ancillar y ancillary ancillary the present equipment for equipment for equipment for document fixed use (base vehicular use portable use station equipment) (mobile equipment) (portable equipment) Applicable Applicable Applicable 9.2 Electrostatic Enclosure discharge Fast transients Signal, common mode telecommunication and control ports, DC and AC power ports Applicable Applicable Applicable 9.3 Applicable Not applicable Not applicable 9.4 RF common Signal, mode 0.15 MHz telecommunication to 80MHz and control ports, DC and AC power ports Applicable Applicable Not applicable 9.5 Applicable 9.6 Not applicable Not applicable Not applicable Not applicable Not applicable 9.8 RF electromagnetic field ( 80MHz to 1GHz) Enclosure Transients and DC power input Not applicable surges ports Voltage dips and AC mains power Applicable interruptions input ports Surges, line to AC mains power line and line input ports, ground telecommunication ports Applicable Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 9.7 Test Report ------------------------------------------------------------------------------- 12/45 Chapter 3 Performance Criteria ETSI EN 301 489-17, Subclause 6.2 Table 1 Performance criteria Criteria During test After test A Shall operate as intended Shall operate as intended B C May show degradation of Shall be no degradation of performance performance ( NOTE 1) Shall be no loss of function Shall be no unintentional transmissions May show loss of function (one or more) May show degradation of performance (NOTE 1) No unintentional transmissions (NOTE 2) Shall be no loss of function Shall be no loss of stored data or user programmable functions Function shall be self-recoverable Shall operate as intended after recovering Shall be no degradation of performance (NOTE 2) Shall be no loss of stored data or user programmable functions May be loss of function (one or more) Functions shall be recoverable by the operator Shall operate as intended after recovering Shall be no degradation of performance (NOTE 2) Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 13/45 NOTE 1: Degradation of performance during the test is understood as a degradation to a level not below a minimum performance level specified by the manufacturer for the use of the apparatus as intended. In some cases the specified minimum performance level may be replaced by a permissible degradation of performance. If the minimum performance level or the permissible performance degradation in not specified by the manufacturer then either of these may be derived from the product description and documentation (including leaflets and advertising) and what the user may reasonably expect form the apparatus if used as intended. NOTE 2: No degradation of performance after the test is understood as no degradation below a minimum performance level specified by the manufacturer for the use of the apparatus as intended. In some cases the specified minimum performance level may be replaced by a permissible degradation of performance. After the test no change of actual operating data or user retrievable data is allowed. If the minimum performance level or the permissible performance degradation in not specified by the manufacturer then either of these may be derived from the product description and documentation (including leaflets and advertising) and what the user may reasonably expect form the apparatus if used as intended. Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 14/45 ETSI EN 301 489-1 Performance criteria for Continuous phenomena applied Transmitters (CT) If no further details are given in the relevant part of the present document dealing with the particular type of radio equipment, the following general performance criteria for continuous phenomena shall apply. During and after the test: The apparatus shall continue to operate as intended. No degradation of performance or loss of function is allowed below a permissible performance level specified by the manufacturer when the apparatus is used as intends. In some cases this permissible performance level may be replaced by a permissible loss of performance. During the test: The EUT shall not unintentionally transmit or change its actual operating state and stored data. If the minimum performance level or the permissible loss is not specified by the manufacturer, then either of these may be deduced from the product description and documentation and what the user may reasonably expect form the apparatus if used as intended. For ancillary equipment the pass/failure criteria supplied by the manufacturer (see subclause 6.4) shall apply, unless the ancillary equipment is tested in connection with a receiver or transmitter in which case the corresponding performance criteria above shall apply. Performance criteria for Transient phenomena applied Transmitters (TT) If no further details are given in the relevant part of the present document dealing with the particular type of radio equipment, the following general performance criteria for transient phenomena shall apply. After the test: The apparatus shall continue to operate as intended. No degradation of performance or loss of function is allowed below a permissible performance level specified by the manufacturer when the apparatus is used as intends. In some cases this permissible performance level may be replaced by a permissible loss of performance. During the test: The EMC exposure to an electromagnetic phenomenon, a degradation of performance is, however, allowed. No change of the actual mode of operation (e.g. unintended transmission) or stored data is allowed. Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 15/45 If the minimum performance level or the permissible loss is not specified by the manufacturer, Then either of these may be deduced from the product description and documentation and what the user may reasonably expect form the apparatus if used as intended. For ancillary equipment the pass/failure criteria supplied by the manufacturer (see subclause 6.4) shall apply, unless the ancillary equipment is tested in connection with a receiver or transmitter in which case the corresponding performance criteria above shall apply. Performance criteria for Continuous phenomena applied Receivers (CR) If no further details are given in the relevant part of the present document dealing with the particular type of radio equipment, the following general performance criteria for continuous phenomena shall apply. During and after the test: The apparatus shall continue to operate as intended. No degradation of performance or loss of function is allowed below a permissible performance level specified by the manufacturer when the apparatus is used as intends. In some cases this permissible performance level may be replaced by a permissible loss of performance. During the test: The EUT shall not unintentionally transmit or change its actual operating state and stored data. If the minimum performance level or the permissible loss is not specified by the manufacturer, then either of these may be deduced from the product description and documentation and what the user may reasonably expect form the apparatus if used as intended. For ancillary equipment the pass/failure criteria supplied by the manufacturer (see subclause 6.4) shall apply, unless the ancillary equipment is tested in connection with a receiver or transmitter in which case the corresponding performance criteria above shall apply. Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 16/45 Performance criteria for Transient phenomena applied Receivers (TR) If no further details are given in the relevant part of the present document dealing with the particular type of radio equipment, the following general performance criteria for transient phenomena shall apply. After the test: The apparatus shall continue to operate as intended. No degradation of performance or loss of function is allowed below a permissible performance level specified by the manufacturer when the apparatus is used as intends. In some cases this permissible performance level may be replaced by a permissible loss of performance. During the test: The EMC exposure to an electromagnetic phenomenon, a degradation of performance is, however, allowed. No change of the actual mode of operation (e.g. unintended transmission) or stored data is allowed. If the minimum performance level or the permissible loss is not specified by the manufacturer, then either of these may be deduced from the product description and documentation and what the user may reasonably expect form the apparatus if used as intended. For ancillary equipment the pass/failure criteria supplied by the manufacturer (see subclause 6.4) shall apply, unless the ancillary equipment is tested in connection with a receiver or transmitter in which case the corresponding performance criteria above shall apply. Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 17/45 ETSI EN 301 489-17 Performance criteria for Continuous phenomena applied Transmitters (CT) The performance criteria A shall apply. Tests shall be repeated with the EUT in standby mode (if applicable) to ensure that unintentional transmission does not occur. In systems using acknowledgement signals, it is recognized that an ACKnowledgement (ACK) or Not ACKnowledgement (NACK) transmission may occur, and steps should be taken to ensure that any transmission resulting from the application of the test is correctly interpreted. Performance criteria for Transient phenomena applied Transmitters (TT) The performance criteria B shall apply, except for voltage dips of 100ms and voltage interruptions of 5000 ms duration, for which performance criteria C shall apply. Tests shall be repeated with the EUT in standby mode (if applicable) to ensure that unintentional transmission does not occur. In system using acknowledgement signals, it is recognized that an acknowledgement (ACK) or not-acknowledgement (NACK) transmission may occur, and steps should be taken to ensure that any transmission resulting from the application of the test is correctly interpreted. Performance criteria for Continuous phenomena applied Receivers (CR) The performance criteria A shall apply. Where the EUT is a transceiver, under no circumstances, shall the transmitter operate unintentionally during the test. In systems using acknowledgement signals, it is recognized that an ACK or NACK transmission may occur, and steps should be taken to ensure that any transmission resulting from the application of test is correctly interpreted. Performance criteria for Transient phenomena applied Receivers (TR) The performance criteria B shall apply, except for voltage dips of 100ms and voltage interruptions of 5000 ms duration, for which performance criteria C shall apply. Where the EUT is a transceiver, under no circumstances, shall the transmitter operate unintentionally during the test. In systems using acknowledgement signals, it is recognized that an ACK or NACK transmission may occur, and steps should be taken to ensure that any transmission resulting from the application of test is correctly interpreted. Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 18/45 Chapter 4 Electrostatic Discharges Immunity Test ESD Test information: Test setup: Shielded room, According to EN 61000-4-2 Test setup for table-top equipment at laboratory tests: Typical position for indirect discharge to VCP Typical position for indirect discharge Typical position for indirect discharge to HCP VPC 0.5m X 0.5m Insulation Horizontal coupling place 1.6m X 0.8m Power Supply 0.1 m Wooden table H=0.8m 470kohm Resistor Ground Reference Plane Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 19/45 Test levels: (Apply Level 2 and Level 3) 1a —Contact discharge Level Test voltage 1b —Air discharge Level Test voltage (kV) (kV) 1 2 1 2 2 3 4 6 2 3 4 8 4 8 4 15 X Special X Special NOTE: “X” is an open level. The level has to be specified in the dedicated equipment specification. If higher voltages than those shown are specified, special test equipment may be needed. Test Voltage: ( X ) 4KV contact discharge ( X ) 8KV air discharge Indirect Discharges: ( X ) HCP ( X ) VCP Polarity: ( X ) Positive ( X ) Negative Test mode: Ref. Test method of Chapter 1 Test points: enclosure and connectors of EUT. Test instruments: Name Best Plus BURST ESD SURGE TRANSIENTS BEST EMC Test Instrument Model Number Best Plus V6.2 Serial Number 199749-019SC BEST EMC V2.3 (-8, -9) 199918-006SC KeyTek Instrument ESD Test system Series 2000 9204303/9204310 9209226/9301395 NoiseKen Electrostatic ESS-100L(A) Discharge Simulator NoiseKen Electrostatic TC-815P Discharge Gun Selected X 2100C03605 2100C03566 Comment: Performance Criteria: (According to ETSI EN 301 489-1) ( X ) Enclosure ( )CT ( X )TT ( ) CR ( X )TR ( X ) Signal and control ports ( )CT ( X )TT ( ) CR ( X )TR Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 20/45 EN 61000-4-2 PHOTO OF TEST SET-UP Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 21/45 Chapter 5 Radio Frequency Immunity Test (RS) RS Test inform ation: Test setup: GTEM cell Radiated Immunity Test Setup Model 7122 Isotropic Probe High Power Amplifier GTEMI Cell EUT Signal Generator EUT Performance Monitor Model 7122 Companion Metering Unit Modulation Generator Model 7110 Data Processing / Interface Unit Test levels: (Apply Level 2) Level Test Field Strength (V/m) 1 1 2 3 3 10 X Special NOTE: the “X” is an open test level. This level may be given in the product specification. Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 22/45 Field strength: ( X ) 3V/m at 80 ~ 1000 MHz ( X ) 3 V/m at 1400 ~ 2000 MHz ( ) FM % Modulation: ( X ) 80% AM Modulation with 1KHz ( ( ( X ) 1% step size ( X ) 2.5 Second Step size: Sweep time: Test mode: ) 80% AM Modulation with 400Hz when signal is modulated at 1kHz ) 900 KHz² 5 KHz with PM 200 Hz and 100% depth Ref. Test method of Chapter 1 Test instruments: Name EMCO GTEM Model Number 5317 Serial Number 9411-1123 Selected X EMCO Probe 7122 9406-1194 X EMCO METERING UNIT 7122 9406-1194 X EMCO data interface HP Personal Computer 7110 D3178A 9410-1273 3438S00486 X X HP Signal Generator 8657B 2928U00286 X HP Signal Generator IFI Wideband Amplifier 83711A SMX50 3429A00434 467-0795 X X Min-circuit Amplifier GFL-2500VH N/A X WG radiation meters WG E-filed EMC-20 2244 / 90.20 BN2244129 Z-0001 X X HP Transmission Test Set 4935A 3115A24046 X B & K Precision Sound Level Meter Type 2232 1810564 X Comment: Performance Criteria: (According to ETSI EN 301 489-1) ( X ) Enclosure ( X )CT ( )TT ( X ) CR ( )TR Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 23/45 EN 61000-4-3 PHOTO OF TEST SET-UP Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 24/45 Chapter 6 Electric Fast Transient/Burst Requirements Test EFT Test information: General test set-up for laboratory type tests: > 0.25 m > 0.25 m > 0.25 m > 0.25 m EUT (L) (L) EUT AC mains supply Capacitive coupling clamp AC mains supply EUT EUT 0.1 m 0.1 m Insulating support Reference plane EFT/Bgenerator (B) Grounding connection according to the manufacturer’ s specification. Length to be specified in the test plan. Non-metallic table EFT/Bgenerator (L) = length between clamp and EUT to be tested, should not be more than 1-meter (A) = location for supply line coupling (B) = location for signal lines coupling Coupling / decoupling network (A) Reference plane Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 25/45 Test levels: (Apply Level 2) Open-circuit output test voltage (±10%) and repetition rate of the impulses (±20%) On power supply port, PE On input/output signal, data and Level control ports Voltage peak Repetition rate Voltage peak Repetition rate kV kHz kV kHz 1 0.5 5 0.25 5 2 1 5 0.5 5 3 2 5 1 5 4 X 4 Special 2.5 Special 2 Special 5 Special NOTE: the “X” is an open level. The level has to be specified in the dedicated equipment specification Test setup: According to EN 61000-4-4 Test Voltage: DC Power line ( ) 0.5 KV, 5 KH AC Power line ( X ) 1 KV, 5 KHz Signal & Control line ( X ) 0.5 KV, 5 KHz; ( ) 1 KV, 5 KHz Polarity: ( X ) Positive ( X ) Negative Test Duration: ( X ) 1 minute ( ) 3 minutes Connected lines: ( ) Power line shielded ( X ) Power line non-shielded ( X ) Signal & Control line non-shielded ( ) Signal & Control line shielded Test mode: Ref. Test method of Chapter 1. Test instrument: Name Model Number Best Plus BURST ESD Best Plus V6.2 SURGE TRANSIENTS Serial Number 199749-019SC Selected BEST EMC Test Instrument BEST EMC V2.3 (-8, -9) 199918-006SC KeyTek Instrument EFT Test system E412 9505206/505207 X Comment: Performance Criteria: (According to ETSI EN 301 489-1) ( X ) Signal and control ports ( )CT ( X )TT ( ) CR ( X )TR ( ) DC power input ports ( )CT ( )TT ( ) CR ( )TR ( X ) AC mains input ports ( )CT ( X )TT ( ) CR ( X )TR Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 26/45 EN 61000-4-4 PHOTO OF TEST SET-UP Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 27/45 Chapter 7 Surge Immunity Test Surge Test information: Test setup: According to EN 61000-4-5 Test levels: (Apply Level 2 and Level 3) Level Test Field Strength (kV) 1 0.5 2 3 1.0 2.0 4 4.0 X Special NOTE: the “X” is an open class. This level may be specified in the product specification. Test Voltage: DC Power line ( ) 0.5 KV AC Power line ( ) Line – Line: 1KV ( ) Line – Ground: 2KV ( X ) Line – Line: 0.5KV ( X ) Line – Ground: 1KV Control line ( ) 0.5 KV Signal ( ) 1 KV, ( X ) 0.5KV Time: ( X ) 1.2/50µs (8/20µs) Polarity: ( X ) Positive ( X ) Negative Connected lines: ( ) Power line shielded ( X ) Power line non-shielded ( X ) Signal & Control line non-shielded ( ) Signal & Control line shielded Test mode: Ref. Test method of Chapter 1. Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 28/45 Test instrument: Name Model Number Best Plus BURST ESD Best Plus V6.2 Serial Number 199749-019SC SURGE TRANSIENTS BEST EMC Test BEST EMC V2.3 199918-006SC Selected Instrument (-8, -9) KeyTek Pulsed-EMI E103, 501B, E502B, 0008260 ~0008264, Test System E503, E505A, E4552A 0008254 X Comment: Performance Criteria: (According to ETSI EN 301 489-1) ( X ) AC mains input ports ( )CT ( X )TT ( ) CR ( X )TR ( X ) Signal and control ports ( )CT ( X )TT ( ) CR ( X )TR Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 29/45 EN 61000-4-5 PHOTO OF TEST SET-UP Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 30/45 Chapter 8 Continuous Wave Voltage Immunity Test CS Test information: Test setup: According to EN 61000-4-6 Immunity test to RF conducted disturbances: CDN: Coupling and decoupling network Auxiliary equipment 1 CDN Equipment under test Auxiliary equipment 1 CDN 0.1 m support Ground reference plane T T2: Power attenuator (6dB) T: Termination 50ohm T2 RF —generator Test generator Test levels: (Apply Level 2) Frequency range 150kHz to 80MHz Level Voltage level (e.m.f.) 1 Uo [dB(µv)] 120 Uo [V] 1 2 130 3 3 X 140 10 Special NOTE: the “X” is an open test level. Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 31/45 Test Frequency: ( X ) 0.15 ~ 80MHz Modulation: ( ) FM % ( X ) 80% AM Modulation with 1kHz Step size: ( ( ) 80% AM Modulation with 400Hz when signal is modulated at 1kHz ) 900 MHz² 5 MHz with PM 200 Hz and 50% duty cycle ( ) Performed over the frequency range 150kHz to 80MHz with the exception of an exclusion band for transmitters, and for receivers and duplex transceivers ( X ) For receivers and transmitters the stepped frequency increments shall be 1% frequency increment of the momentary frequency in the frequency range 150kHz to 80MHz, unless specified otherwise in the part of EN 301 489 dealing with the particular type of radio equipment Field strength: ( ) 1Vrms ( X ) 3Vrms ( Connected lines: ( ) Power line shielded ( X ) Power line non-shielded ( X ) Signal & Control line non-shielded ( ) Signal & Control line shielded ) 10Vrms Test mode: Ref. Test method of Chapter 1 Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 32/45 Test instruments: Name Model Number Serial Number Selected FRANKONIA EMV–Mess– CIT-10 103A3113 X System FRANKONIA CDN M2+M3 A3011015 X FRANKONIA CDN T2-801 A3010002 FRANKONIA CDN FRANKONIA CDN T4-801 S1-801 A3015004 A3005002 SCHAFFNER FM-Koppelzange KEMZ 801 17045 SCHAFFNER RF-SYNTHE SIZERIAMP21FIER SCHAFFNER CDN SCHAFFNER CDN NSG 2070-1 1020 M325 M216 13773 15604 SCHAFFNER CDN T004 15230 SCHAFFNER CDN SCHAFFNER FM-Koppelzange S501 KEMZ 801 15167 14301 HP Transmission Test Set 4935A 3115A24046 B & K Precision So und Level Meter Type 2232 X 1810564 Comment: Performance Criteria: (According to ETSI EN 301 489-1) ( ) Antenna port ( )CT ( )TT ( ) CR ( )TR ( X ) Signal and control ports ( X )CT ( )TT ( X ) CR ( )TR ( ) DC power input ports ( )CT ( )TT ( ) CR ( )TR ( X ) AC mains input ports ( X )CT ( )TT ( X ) CR ( )TR Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 33/45 EN 61000-4-6 PHOTO OF TEST SET-UP Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 34/45 Chapter 9 Voltage DIP / Interruption Test DIP Test information: Test setup: According to EN 61000-4-11 Voltage dips: ( X ) 30%, 0.01 Second ( X ) 60%, 0.1 Second Voltage interruptions: ( X ) > 95%, 5 Seconds Test mode: Ref. Test method of Chapter 1 Test instruments: Name Model Number Best Plus BURST ESD Best Plus V6.2 SURGE TRANSIENTS Serial Number 199749-019SC BEST EMC Test Instrument BEST EMC V2.3 (-8, -9) 199918-006SC Partner EMS Tester Transienter-1000 PIO Selected X Comment: Performance Criteria: (According to ETSI EN 301 489-1) Dips 30%: ( X ) CT ( ) TT ( X ) CR Dips 60%: ( ) CT ( ) TT ( ) CR Interruptions >95%: ( ) CT ( ) TT ( ) CR No unintentional responses shall occur at the end of the test; ( )Event of loss of function(s) ( )Event of loss of user stored data Performance Criteria: (According to ETSI EN 301 489-17) Dips 60%, 100 ms : ( ) A ( )B Interruptions >95%, 5 000 ms: ( ) A ( )B Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 ( ) TR ( ) TR ( ) TR (X)C (X)C Test Report ------------------------------------------------------------------------------- 35/45 EN 61000-4-11 PHOTO OF TEST SET-UP Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 36/45 Chapter 10 Harmonics Test Test information: Test setup: According to EN 61000-3-2 Test item: Test mode: Quasi – stationary & Fluctuating Current Harmonics Test. Ref. Test method of Chapter 1 Test instrument: Name Model Number Harmonic/Flicker Test HP 6842A System Test Equipment Settings: Serial Number 3531A-00102 Selected X Line Voltage Quasi-stationary Current Harmonics Test 230VAC Fluctuating Current Harmonics Test 230VAC Line Frequency Device Class 50Hz A 50Hz A Test Limit Overrides None None Total Number of Failures: None None Total Number of Errors: None None Test Result: Pass Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 37/45 Chapter 11 Voltage Fluctuation and Flicker Test Test information: Test setup: According to EN 61000-3-3 Test mode: Ref. Test method of Chapter 1 Test instrument: Name Model Number Harmonic/Flicker Test HP 6842A System Serial Number 3531A-00102 Selected X Test Equipment Settings: Line Voltage 230VAC Line Frequency 50Hz Test Limit Overrides None Total Number of Failures: Pst: (0), Plt: (0) Dc: (0), Dmax (0), Dt (0) Total Number of Errors: None Test Result: Pass Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 38/45 Chapter 12 Conducted Emission Test Test condition and setup All the equipment is placed and setup according to EN 55022. Mains power: The EUT is assembled on a wooden table, which is 80 cm high and placed 40 cm from the back-wall, which is a vertical conducting plane. One LISN is for EUT, the other LISN is for support equipment. They are all placed on the conductive ground. The EUT’ s LISN connect a line switch box for selecting L1 or L2, then connect to a preamplifier and spectrum. The spectrum scans from 150KHz to 30MHz. Conducted emission levels are detected at maximum peak mode. But if the maximum peak mode failed or over average limit, it will be measured by average detection mode. While testing the worst-emission plot printed in the peak detection mode, and there are up to 6 highest e missions to be recorded. The plot is kept as the original data and not included in the test report. List of test Instrument Calibration Date Instrument Name Model No. Brand Serial No. Last time Next time EMI Receiver RF Filter Section LISN (EUT) LISN (Support E.) Auto Switch Box (< 30MHz) 8546A 85460A LISN-01 LISN-01 ASB-01 HP HP TRC TRC TRC 3520A00242 3448A00217 9912-03,04 9912-05 9904-01 07/28/03 07/28/03 07/21/03 06/21/03 11/20/02 07/28/04 07/28/04 07/21/04 06/21/04 11/20/03 The level of confidence of 95%, the uncertainty of measurement of conducted emission is +2.43dB / -2.53dB. Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 39/45 Conducted Test Placement (Front view and Side view) Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 40/45 Test Result of Conducted Emissions for Mains power Test Conditions: Temperature : 25 °C Humidity : 73 % RH Test Mode: Standby mode Power Connected Conductor Frequency (KHz) Line 1 Line 2 Emissions Class B Peak QP Average QP-limit AVG-limit Margin (dBµ V) (dBµ V) (dBµ V) (dBµ V) (dBµ V) (dB) 159.000 48.70 --- --- 65.74 55.74 -7.04 201.000 45.90 --- --- 64.54 54.54 -8.64 257.000 43.12 --- --- 62.94 52.94 -9.82 355.000 43.26 --- --- 60.14 50.14 -6.88 485.000 40.52 --- --- 56.43 46.43 -5.91 668.000 39.73 --- --- 56.00 46.00 -6.27 16230.000 43.39 --- --- 60.00 50.00 -6.61 17710.000 42.66 --- --- 60.00 50.00 -7.34 20200.000 41.89 --- --- 60.00 50.00 -8.11 23120.000 40.41 --- --- 60.00 50.00 -9.59 118.640 52.90 49.17 25.26 65.86 55.86 -16.69 180.000 50.79 --- --- 65.14 55.14 -4.35 229.000 48.66 --- --- 63.74 53.74 -5.08 373.710 47.06 40.17 24.80 59.91 49.91 -19.74 401.390 45.83 39.63 23.87 57.37 47.37 -17.74 507.550 44.79 38.15 22.42 56.00 46.00 -17.85 603.500 44.50 37.43 20.44 56.00 46.00 -18.57 767.000 42.96 --- --- 56.00 46.00 -3.04 16160.000 43.00 --- --- 60.00 50.00 -7.00 17710.000 43.13 --- --- 60.00 50.00 -6.87 *The reading amplitudes are all under limit. Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 41/45 Test Conditions: Temperature : 25 °C Humidity : 73 % RH Test Mode: Linking mode Power Connected Conductor Frequency (KHz) Line 1 Line 2 Emissions Class B Peak QP Average QP-limit AVG-limit Margin (dBµ V) (dBµ V) (dBµ V) (dBµ V) (dBµ V) (dB) 118.340 52.87 44.56 10.90 65.63 55.63 -21.07 212.000 49.75 --- --- 64.23 54.23 -4.48 271.000 46.99 --- --- 62.54 52.54 -5.55 365.810 47.38 38.21 24.84 60.03 50.03 -21.82 368.790 46.53 38.33 23.92 58.11 48.11 -19.78 421.680 46.14 36.56 23.92 56.83 46.83 -20.27 617.050 44.59 33.08 23.45 56.00 46.00 -22.92 802.000 42.16 --- --- 56.00 46.00 -3.84 18240.000 35.05 --- --- 56.00 46.00 -10.95 23120.000 39.82 --- --- 60.00 50.00 -10.18 163.000 48.58 --- --- 65.63 55.63 -7.05 197.000 46.18 --- --- 64.66 54.66 -8.48 231.000 44.61 --- --- 63.69 53.69 -9.08 267.000 42.81 --- --- 62.66 52.66 -9.85 366.000 43.83 --- --- 59.83 49.83 -6.00 426.000 41.67 --- --- 58.11 48.11 -6.44 490.000 40.93 --- --- 56.29 46.29 -5.36 731.000 39.65 --- --- 56.00 46.00 -6.35 19620.000 35.84 --- --- 60.00 50.00 -14.16 26540.000 39.35 --- --- 60.00 50.00 -10.65 *The reading amplitudes are all under limit. Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 42/45 Chapter 13 Radiated Emission Test Test condition and setup Pretest: Prior to the final test (OATS test), the EUT is placed in a shielded enclosure, and scan from 30MHz to 1GHz. This is done to ensure the radiation is exactly emitted from the EUT. Final test: Final radiation measurements are made on a 10 – meter, open-field test site. The EUT is placed on a nonconductive table, which is 0.8m height, the top surface is 1.0 x 1.5 meter. The entire placement is according to EN 55022. The whole range antenna is used to measure frequency from 30 MHz to 1GHz. The final test is used the spectrum analyzer (EMI Receiver). Measure more than six top marked frequencies generated form pretest by computer step by step at each frequency. The EUT is rotated 360 degrees, and antenna is raised and lowered from 1 to 4 meters to find the maximum emission levels. The antenna is used with both horizontal and vertical polarization. Appropriated preamplifier which is made by TRC is used for improving sensitivity and precautions is taken to avoid overloading .The spectrum analyzer’ s 6dB bandwidth is set to 120 kHz, and the EUT is measured at quasi-peak (below 1GHz) mode. If the emission is close to the frequency band of ambient, the tester will recheck the data and the corrected data will be written in the test data sheet. If the emission is just within the ambient, the data from shielded room will be taken as the final data. List of test Instrument Calibration Date Instrument Name Model No. Brand Serial No. Receiver SCR3102 SCHAFFNER 021 Control box TWR95-4 TRC C9001-2 Antenna CBL6141A SCHAFFNER 4206 Pre-amplifier TRC-CB-2 TRC CB-002 Jyebao CL-002 Coixal cable (20m) RG-214/U CL-002 Coixal cable (50cm) BNC31VB-0316 Jyebao CL-007 Coixal cable (20cm) BNC31VB-0318 Jyebao CL-006 Coixal cable (55cm) BNC31VB-0316 Jyebao CL-005 Coixal cable (55cm) BNC31VB-0316 Jyebao Open test side (Antenna, Amplify, cable calibrated together) Last time 04/22/03 None 05/27/03 05/29/03 05/29/03 05/29/03 05/29/03 05/29/03 05/29/03 05/15/03 Next time 04/22/04 None 05/27/04 05/29/04 05/29/04 05/29/04 05/29/04 05/29/04 05/29/04 05/15/04 The level of confidence of 95% , the uncertainty of measurement of radiated emission is +2.85d B / -2.77dB. Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 43/45 Radiated Test Placement (Front view and Side view) Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 44/45 Test Result of Spurious Radiated Emissions Test Conditions: Temperature : 25 ° C Humidity : 73 % RH Test Mode: Linking mode, Horizontal Radiated Emission Table ( ± ) Frequency Amplitude Ant. H. (m) (MHz) (dBµ V) Correction Corrected Factors Amplitude (dB) Class B ( 10 m ) Limit (dBµ V/m) (dBµ V/m) Margin (dB) 205.3338 29.17 2.50 326 -3.85 25.32 30.00 -4.68 250.0163 33.50 2.50 359 -1.80 31.70 37.00 -5.30 308.0000 32.20 2.50 308 -0.99 31.21 37.00 -5.79 425.0288 28.46 2.50 218 5.10 33.56 37.00 -3.44 475.0275 24.22 2.50 18 6.20 30.42 37.00 -6.58 Test Mode: Linking mode, Vertical Radiated Emission Frequency Amplitude Ant. H. (MHz) (dBµ V) (m) Table ( ± ) Correction Corrected Factors Amplitude (dB) Class B ( 10 m ) Limit (dB µ V/m) (dBµ V/m) Margin (dB) 30.2700 19.57 1.00 118 4.79 24.36 30.00 -5.64 124.4638 30.95 2.51 359 -4.73 26.22 30.00 -3.78 205.5685 27.62 2.51 324 -3.84 23.78 30.00 -6.22 250.0163 37.66 1.00 170 -1.80 35.86 37.00 -1.14 410.6675 28.53 2.51 105 4.81 33.34 37.00 -3.66 Note: 1. Margin = Amplitude – limit, if margin is minus means under limit. 2. Corrected Amplitude = Reading Amplitude + Correction Factors 3. Correction factor = Antenna factor + ( Cable Loss – Amplitude gain) Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440 Test Report ------------------------------------------------------------------------------- 45/45 Appendix A Brand name and Model name List Brand Name Model Name TRENDware TEW-231BRP Report No.: C51ET385 (ETSI EN 301489) Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 46 Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:5fc645db-0e54-4983-8984-3ebb3e97df59 Modify Date : 2004:03:25 14:07:36-08:00 Create Date : 2004:03:25 13:49:27-08:00 Metadata Date : 2004:03:25 14:07:36-08:00 Document ID : uuid:ad7ee6a3-8cbc-4d63-9195-7874e6fd21fe Format : application/pdf Title : Microsoft Word - Application Form.doc Creator : ADOBEPS4.DRV Version 4.50 Author : weng Producer : Acrobat Distiller 5.0.5 (Windows)EXIF Metadata provided by EXIF.tools