TRENDware
TEW-231BRP
EMC TEST REPORT
Report No: C51ET385

Test Report ------------------------------------------------------------------------------- 1/45
Report No.

C51ET385

Specifications

ETSI EN 301 489-1 V1.4.1 (August, 2002)
ETSI EN 301 489-17 V1.2.1 (April, 2002)

Applicant

TRENDware International Inc.

Applicant
address

3135 Kashiwa Street
Torrance, CA 90505, USA

Items tested
Model No.

IEEE 802.11b Wireless LAN Broadband Router
TEW-231BRP

Results

Compliance (As detailed within this report)

Date

11/20/2003 (month / day / year) (Sample received)
11/24/2003 (month / day / year) (Test)

Prepared by
______________________
Authorized by
Issue date

December 10, 2003

Project Engineer
(Jack Tsai)
General Manager
(Frank Tsai)
(month / day / year)

Modifications
Tested by

None
Training Research Co., Ltd.

Office at

No. 255, Nan Yang Street, Shijr City, Taipei Hsien 221, Taiwan

Laboratory at

1F, No. 255, Nan Yang Street, Shijr City, Taipei Hsien 221, Taiwan

Open site at

No. 15, Lane 530, Balian Rd., Sec. 1, Shijr City, Taipei Hsien 221, Taiwan

Conditions of issue:
This test report shall not be reproduced except in full, without written approval of
TRC. And the test result contained within this report only relate to the sample
submitted for testing.

Ϫʳ Aut. No. ELA 131
Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 2/45

Generally Statement:
The results appear in the following order:
Electromagnetic compatibility and radio spectrum matters (ERM); Electro Magnetic
Compatibility (EMC) standard for radio equipment and services;
Part 1: Common Technical requirements
Part 17:Specific conditions for Wideband data and HIPERLAN equipment.
The results exhibits below only apply to particular samples tested and to the specific tests
carried out, as detailed in this Test Report. The issue of this Test Report does not indicate any
measure of Approval, Certification, Supervision, Control or Surveillance by Training Research
Co., Ltd. of any product. No extract, abridgement or abstraction from a Test Report may be
published or used to advertise a product without the written consent of the Director, Training
Research Co., Ltd. who reserves the absolute right to agree or reject all or any of the details of
any item of publicity for which consent may be sought.

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 3/45

Contents
CHAPTER 0

EMISSION AND SUSCEPTIBILITY STANDARDS........5
EMISSION STANDARDS.......................................................... 5
SUSCEPTIBILITY STANDARDS.................................................................... 5

CHAPTER 1

INTRODUCTION..............................................................6
DESCRIPTION OF EUT............................................................................... 6
TEST M ETHOD .......................................................................................... 6
LIST OF SUPPORT EQUIPMENT ................................................................... 7

CHAPTER 2

EMISSION AND IMMUNITY REQUIREMENTS
OVERVIEW....................................................................10
EMISSION (ETSI EN 301 489-1)............................................................. 10
IMMUNITY (ETSI EN 301 489-1)............................................................ 11

CHAPTER 3

PERFORMANCE CRITERIA.........................................12
ETSI EN 301 489-17, SUBCLAUSE 6.2 ................................................... 12

CHAPTER 4

ELECTROSTATIC DISCHARGES IMMUNITY TEST 18
ESD TEST INFORMATION:....................................................................... 18
EN 61000-4-2 PHOTO OF TEST SET-UP............................................ 20

CHAPTER 5

RADIO FREQUENCY IMMUNITY TEST (RS).............21
RS TEST INFORMATION:.......................................................................... 21
EN 61000-4-3 PHOTO OF TEST SET-UP............................................ 23

CHAPTER 6

ELECTRIC FAST TRANSIENT/
BURST REQUIREMENTS TEST ..................................24
EFT TEST INFORMATION: ....................................................................... 24
EN 61000-4-4 PHOTO OF TEST SET-UP............................................ 26

CHAPTER 7

SURGE IMMUNITY TEST.............................................27
SURGE TEST INFORMATION:.................................................................... 27
EN 61000-4-5 PHOTO OF TEST SET-UP............................................ 29

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 4/45

CHAPTER 8

CONTINUOUS WAVE VOLTAGE IMMUNITY TEST 30
CS TEST INFORMATION:.......................................................................... 30
TEST INSTRUMENTS: ............................................................................... 32
EN 61000-4-6 PHOTO OF TEST SET-UP............................................ 33

CHAPTER 9

VOLTAGE DIP / INTERRUPTION TEST .....................34
DIP TEST INFORMATION:........................................................................ 34
EN 61000-4-11 PHOTO OF TEST SET-UP.......................................... 35

CHAPTER 10 HARMONICS TEST........................................................36
CHAPTER 11 VOLTAGE FLUCTUATION AND FLICKER TEST.....37
CHAPTER 12 CONDUCTED EMISSION TEST....................................38
TEST CONDITION AND SETUP ................................................................... 38
LIST OF TEST INSTRUMENT ..................................................................... 38
CONDUCTED TEST P LACEMENT (FRONT VIEW AND SIDE VIEW ).............. 39
TEST RESULT OF CONDUCTED EMISSIONS FOR M AINS POWER................ 40

CHAPTER 13 RADIATED EMISSION TEST........................................42
TEST CONDITION AND SETUP ................................................................... 42
LIST OF TEST INSTRUMENT ..................................................................... 42
RADIATED TEST P LACEMENT (FRONT VIEW AND SIDE VIEW ) ................. 43
TEST RESULT OF SPURIOUS RADIATED EMISSIONS ................................. 44

APPENDIX A

.........................................................................................45
BRAND NAME AND M ODEL NAME LIST ................................................... 45

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 5/45

Chapter 0

Emission and Susceptibility Standards

Emission Standards
Emission Standard

European Standard

International Standard

(

)

EN 61000-6-3/2001

IEC 61000-6-3/1996

(

)

EN 61000-6-4/2001

IEC 61000-6-4/1997

(

)

EN 50081-1/1992

(

)

EN 50081-1/8.93

(

)

EN 55014/4.93

CISPR 14: 1993

(

)

EN 55015/12.93

CISPR 15: 1992

(

)

EN 55011/91

CISPR 11: 1990

( X)

EN 55022/98

( X)

EN 61000-3-2/2000

CISPR 22: 1997
IEC 61000-3-2: 2000 (Modified)

( X)

EN 61000-3-3/1995

IEC 61000-3-3: 1994 + A1/2001

Susceptibility Standards
Susceptibility Standard

European Standard

International Standard

(

)

EN 61000-6-1/2001

IEC 61000-6-1/1997

(

)

EN 61000-6-2/2001

IEC 61000-6-2/1999

(

)

EN 50082-1/1997

(

)

EN 50082-2/1994

(

)

EN 55024/1998

CISPR 24/1997

(

)

EN 55020/2002

CISPR 20/2002

(X)

EN 61000-4-2:1995

IEC 61000-4-2:1995

(X)

EN 61000-4-3:1996

IEC 61000-4-3:1995

(X)

EN 61000-4-4:1995

IEC 61000-4-4:1995

(X)

EN 61000-4-5:1995

IEC 61000-4-5:1995

(X)

EN 61000-4-6:1996

IEC 61000-4-6:1996

(

EN 61000-4-8:1993

IEC 61000-4-8:1993

(X)

EN 61000-4-11:1994

IEC 61000-4-11:1994

(

EN 55014-2:1993

CISPR/F (Sec) 159

)
)

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 6/45

Chapter 1

Introduction

Description of EUT
Product Name

:

IEEE 802.11b Wireless LAN Broadband Router

Model

:

as Appendix A

Frequency Range

:

2.400GHz ~ 2.4835GHz

Operating Frequency

:

2.412GHz ~ 2.472GHz

Support Channel

:

13 Channels

Modulation Skill

:

DBPSK, DQPSK, CCK

Power Type

:

Power adapter
Model: 48075100-C5
I/P: 230VAC, 50Hz, 90mA
O/P: 7.5 VDC, 1000mA
Power cable 184cm length, non-shielded, no ferrite core

Data Cable

:

RJ45*1, 30m length, non-shielded, no ferrite core
RJ45*3, 2m length, non-shielded, no ferrite core
RJ45*1, 1.2m length, non-shielded, no ferrite core

Test Method
1. Using the computer and software provided by the manufacturer to control EUT.
2. During test, making EUT to the following mode.
(a) EMI testing: Making EUT to the linking mode with support equipments
(b) EMS testing: Making EUT to the linking mode with support equipments

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 7/45

List of Support Equipment
In order to construct the minimum testing, following equipment were used as the support
units.
Notebook
Model No.

:
:

IBM Think Pad X20
2662-11T

Serial No.

:

FX-1192200/09

FCC ID
ᛀ጖

:
:

N/A, Do C Approved (Declaration of Confirmation) Approved
3892B565

Adaptor
Model No.
Serial No.
FCC ID
Power type
Power cord

:
:
:
:
:
:

IBM
PA2450U
02K6654
N/A, Do C Approved
I/P: 100 ~ 240vac, 50 ~ 60 Hz, 0.5A ~ 1.2A; O/P: 16Vdc, 4.5A
Non-shielded, 1.80m long, Plastic, with ferrite core

PC
Model No.
Serial No.
FCC ID
ᛀ጖

:
:
:
:
:

IBM 6840; HP Pavilion
6840MJV; P8574A
96CC 0C1; TW21920435
N/A, Do C
3892I279; 3902H097

Power type
Power cord

:
:

100 ~ 127VAC / 4A, 200 ~ 240VAC/2A, 50 ~ 60Hz, 5A, Switching
Non-shielded, 2.33 m length, Plastic hood, No ferrite core

Printer
Model No.
Serial No.
FCC ID
ᛀ጖

:
:
:
:
:

HP
C6464A, C2642A
TH16LEB5PK, SG69A196GV
None (DoC Approved), B94C2642X

Power type
Power cord

:
:

Data cable

:

Switching adaptor
Non-shielded, 173cm length, No ferrite core
(between adaptor and AC source)
Non-shielded, 180cm length, with ferrite core
(between printer and adaptor)
Shielded, 1.70m length, No ferrite core

3892H381, None

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 8/45

Monitor

:

HP 15’ Color Monitor, HP pavilion mx70

Model No.
Serial No.

:
:

D2827A, P1283A
KR91379759, TWTBQ00397

FCC ID
ᛀ጖

:
:

C5F7NFCMC1518X
3872B039

Power type

:

110 ~ 240 VAC / 50 ~ 60 Hz, Switching

Power cord
Data cable

:
:

Shielded, 1.83m length, No ferrite core
Shielded, 1.46m length, with two ferrite cores

Modem
Model No.
FCC ID
Power type
Power cord
Data cable

:
:
:
:
:
:

ACEEX
XDM-56V14
IFAXDM-56V14
Linear
Non-shielded, 1.9m length, No ferrite cord
RS232, Shielded, 1.2m length, No ferrite core
RJ11C x 2, 7’ length non-shielded, No ferrite core

Mouse
Model No.
Serial No.
FCC ID
ᛀ጖

:
:
:
:
:

HP
M-S34
LZB90714106, LZC84446151
DZL211029
4862A011

Power type
Power cord

:
:

By PC
Non-shielded, 1.88m length, No ferrite core

Keyboard
Model No.
Serial No.

:
:
:

HP
5187-0343, SK-2501K
BE21700404, M981216213

FCC ID
ᛀ጖

:
:

DoC Approved, GYUR38SK
3892C981, 3862A621

Power type
Data cable

:
:

By PC
Shielded, 1.73m length, Plastic hood, No ferrite core

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 9/45

USB Gamepad :

Rockfire

Model No.
Serial No.

:
:

QF-337uv
10600545, KR91379759

FCC ID
ᛀ጖

:
:

None (CE approval)
3862A574

Power type

:

By computer

Data Cable

:

Shielded, 1.81m long, Plastic, with ferrite core

Notebook
Model No.
Serial No.
FCC ID
BSMI
Power type
Adaptor of PC
Model No.
Serial No.
FCC ID
ᛀ጖

:
:
:
:
:
:
:
:
:
:
:

ASUSTek Computer
AB00F
24NP016361
DoC Approved
41016012
100 ~ 240VAC, 1A 50/60 Hz, Switching
LITE-ON Electronics, Inc.
PA-1530-01
00151184
DoC Approved
3882B259

Power cable

:

Power cable

:

Non-shielded, 1.72m length, Plastic hood, No ferrite core
(Between power adaptor and AC power source)
Shielded, 1.48m length, Plastic hood, with ferrite core
(Between power adaptor and notebook)

WLAN Card
Model No.
FCC ID

:
:
:

Gemtek Technology Co., Ltd.
C911003
MXF-C911003

LAN Card
Model No.
Serial No.
FCC ID
Power type

:
:
:
:
:

D-Link
DFE-530TX
0050BAE32FF3, 0050BAE3158B
N/A, DoC Approved
Powered by PC

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 10/45

Chapter 2

Emission and Immunity Requirements Overview

Emission (ETSI EN 301 489-1)
Phenomenon

Application

Equipment test requirement
Radio and

Radio and

Radio and

ancillary

ancillary

ancillary

equipment for
fixed use (base

equipment for
vehicular use

equipment for
portable use

station

(mobile

(portable

equipment)
Applicable for
stand alone
testing

Radiated
emission

Enclosure of
ancillary
equipment

Conducted
emission

DC power
input/output
port

Applicable

Conducted
emission

AC mains
input/output
port
AC mains
input port

Harmonic
current
emissions
Voltage
fluctuations
and flicker

AC mains
input port

equipment)
equipment)
Applicable for Applicable for
stand alone
stand alone
testing
testing
Applicable

Reference
Subclause in
the present
document

8.2

Not applicable

8.3

Applicable

Not applicable Not applicable

8.4

Applicable

Not applicable Not applicable

8.5

Applicable

Not applicable Not applicable

8.6

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 11/45

Immunity (ETSI EN 301 489-1)
Phenomenon

Application

Equipment test requirement
Radio and

Radio and

Radio and

Reference
Subclause in

ancillar y
ancillary
ancillary
the present
equipment for equipment for equipment for document
fixed use (base vehicular use portable use
station
equipment)

(mobile
equipment)

(portable
equipment)

Applicable

Applicable

Applicable

9.2

Electrostatic
Enclosure
discharge
Fast transients
Signal,
common mode telecommunication
and control ports,
DC and AC power
ports

Applicable

Applicable

Applicable

9.3

Applicable

Not
applicable

Not
applicable

9.4

RF common
Signal,
mode 0.15 MHz telecommunication
to 80MHz
and control ports,
DC and AC power
ports

Applicable

Applicable

Not
applicable

9.5

Applicable

9.6

Not
applicable

Not
applicable
Not
applicable

Not
applicable

Not
applicable

9.8

RF
electromagnetic
field ( 80MHz to
1GHz)

Enclosure

Transients and DC power input Not applicable
surges
ports
Voltage dips and AC mains power
Applicable
interruptions
input ports
Surges, line to AC mains power
line and line
input ports,
ground
telecommunication
ports

Applicable

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

9.7

Test Report ------------------------------------------------------------------------------- 12/45

Chapter 3

Performance Criteria

ETSI EN 301 489-17, Subclause 6.2
Table 1 Performance criteria
Criteria
During test
After test
A
Shall operate as intended
Shall operate as intended

B

C

May show degradation of

Shall be no degradation of performance

performance ( NOTE 1)
Shall be no loss of function
Shall be no unintentional
transmissions
May show loss of function (one or
more)
May show degradation of
performance (NOTE 1)
No unintentional transmissions

(NOTE 2)
Shall be no loss of function
Shall be no loss of stored data or user
programmable functions
Function shall be self-recoverable
Shall operate as intended after recovering
Shall be no degradation of performance
(NOTE 2)
Shall be no loss of stored data or user
programmable functions

May be loss of function (one or
more)

Functions shall be recoverable by the
operator
Shall operate as intended after recovering
Shall be no degradation of performance
(NOTE 2)

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 13/45

NOTE 1:
Degradation of performance during the test is understood as a degradation to a level not
below a minimum performance level specified by the manufacturer for the use of the apparatus
as intended. In some cases the specified minimum performance level may be replaced by a
permissible degradation of performance.
If the minimum performance level or the permissible performance degradation in not
specified by the manufacturer then either of these may be derived from the product description
and documentation (including leaflets and advertising) and what the user may reasonably expect
form the apparatus if used as intended.

NOTE 2:
No degradation of performance after the test is understood as no degradation below a
minimum performance level specified by the manufacturer for the use of the apparatus as
intended. In some cases the specified minimum performance level may be replaced by a
permissible degradation of performance. After the test no change of actual operating data or user
retrievable data is allowed.
If the minimum performance level or the permissible performance degradation in not
specified by the manufacturer then either of these may be derived from the product description
and documentation (including leaflets and advertising) and what the user may reasonably expect
form the apparatus if used as intended.

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 14/45

ETSI EN 301 489-1
Performance criteria for Continuous phenomena applied Transmitters (CT)
If no further details are given in the relevant part of the present document dealing with the
particular type of radio equipment, the following general performance criteria for continuous
phenomena shall apply.
During and after the test:
The apparatus shall continue to operate as intended. No degradation of performance or loss
of function is allowed below a permissible performance level specified by the manufacturer
when the apparatus is used as intends. In some cases this permissible performance level may
be replaced by a permissible loss of performance.
During the test:
The EUT shall not unintentionally transmit or change its actual operating state and stored
data. If the minimum performance level or the permissible loss is not specified by the
manufacturer, then either of these may be deduced from the product description and
documentation and what the user may reasonably expect form the apparatus if used as
intended.
For ancillary equipment the pass/failure criteria supplied by the manufacturer (see subclause
6.4) shall apply, unless the ancillary equipment is tested in connection with a receiver or
transmitter in which case the corresponding performance criteria above shall apply.

Performance criteria for Transient phenomena applied Transmitters (TT)
If no further details are given in the relevant part of the present document dealing with the
particular type of radio equipment, the following general performance criteria for transient
phenomena shall apply.
After the test:
The apparatus shall continue to operate as intended. No degradation of performance or loss
of function is allowed below a permissible performance level specified by the manufacturer
when the apparatus is used as intends. In some cases this permissible performance level may
be replaced by a permissible loss of performance.
During the test:
The EMC exposure to an electromagnetic phenomenon, a degradation of performance is,
however, allowed. No change of the actual mode of operation (e.g. unintended transmission)
or stored data is allowed.

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 15/45

If the minimum performance level or the permissible loss is not specified by the
manufacturer, Then either of these may be deduced from the product description and
documentation and what the user may reasonably expect form the apparatus if used as
intended.
For ancillary equipment the pass/failure criteria supplied by the manufacturer (see subclause
6.4) shall apply, unless the ancillary equipment is tested in connection with a receiver or
transmitter in which case the corresponding performance criteria above shall apply.

Performance criteria for Continuous phenomena applied Receivers (CR)
If no further details are given in the relevant part of the present document dealing with the
particular type of radio equipment, the following general performance criteria for continuous
phenomena shall apply.
During and after the test:
The apparatus shall continue to operate as intended. No degradation of performance or loss
of function is allowed below a permissible performance level specified by the manufacturer
when the apparatus is used as intends. In some cases this permissible performance level may
be replaced by a permissible loss of performance.
During the test:
The EUT shall not unintentionally transmit or change its actual operating state and stored
data. If the minimum performance level or the permissible loss is not specified by the
manufacturer, then either of these may be deduced from the product description and
documentation and what the user may reasonably expect form the apparatus if used as
intended.
For ancillary equipment the pass/failure criteria supplied by the manufacturer (see subclause
6.4) shall apply, unless the ancillary equipment is tested in connection with a receiver or
transmitter in which case the corresponding performance criteria above shall apply.

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 16/45

Performance criteria for Transient phenomena applied Receivers (TR)
If no further details are given in the relevant part of the present document dealing with the
particular type of radio equipment, the following general performance criteria for transient
phenomena shall apply.
After the test:
The apparatus shall continue to operate as intended. No degradation of performance or loss
of function is allowed below a permissible performance level specified by the manufacturer
when the apparatus is used as intends. In some cases this permissible performance level may
be replaced by a permissible loss of performance.
During the test:
The EMC exposure to an electromagnetic phenomenon, a degradation of performance is,
however, allowed. No change of the actual mode of operation (e.g. unintended transmission)
or stored data is allowed.
If the minimum performance level or the permissible loss is not specified by the
manufacturer, then either of these may be deduced from the product description and
documentation and what the user may reasonably expect form the apparatus if used as
intended.
For ancillary equipment the pass/failure criteria supplied by the manufacturer (see subclause
6.4) shall apply, unless the ancillary equipment is tested in connection with a receiver or
transmitter in which case the corresponding performance criteria above shall apply.

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 17/45

ETSI EN 301 489-17
Performance criteria for Continuous phenomena applied Transmitters (CT)
The performance criteria A shall apply.
Tests shall be repeated with the EUT in standby mode (if applicable) to ensure that
unintentional transmission does not occur. In systems using acknowledgement signals, it is
recognized that an ACKnowledgement (ACK) or Not ACKnowledgement (NACK) transmission
may occur, and steps should be taken to ensure that any transmission resulting from the
application of the test is correctly interpreted.

Performance criteria for Transient phenomena applied Transmitters (TT)
The performance criteria B shall apply, except for voltage dips of 100ms and voltage
interruptions of 5000 ms duration, for which performance criteria C shall apply.
Tests shall be repeated with the EUT in standby mode (if applicable) to ensure that unintentional
transmission does not occur. In system using acknowledgement signals, it is recognized that an
acknowledgement (ACK) or not-acknowledgement (NACK) transmission may occur, and steps
should be taken to ensure that any transmission resulting from the application of the test is
correctly interpreted.

Performance criteria for Continuous phenomena applied Receivers (CR)
The performance criteria A shall apply.
Where the EUT is a transceiver, under no circumstances, shall the transmitter operate
unintentionally during the test. In systems using acknowledgement signals, it is recognized that
an ACK or NACK transmission may occur, and steps should be taken to ensure that any
transmission resulting from the application of test is correctly interpreted.

Performance criteria for Transient phenomena applied Receivers (TR)
The performance criteria B shall apply, except for voltage dips of 100ms and voltage
interruptions of 5000 ms duration, for which performance criteria C shall apply.
Where the EUT is a transceiver, under no circumstances, shall the transmitter operate
unintentionally during the test. In systems using acknowledgement signals, it is recognized that
an ACK or NACK transmission may occur, and steps should be taken to ensure that any
transmission resulting from the application of test is correctly interpreted.

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 18/45

Chapter 4

Electrostatic Discharges Immunity Test

ESD Test information:
Test setup: Shielded room, According to EN 61000-4-2
Test setup for table-top equipment at laboratory tests:
Typical position for
indirect discharge to VCP

Typical position for
indirect discharge

Typical position for
indirect discharge to HCP

VPC
0.5m X 0.5m

Insulation

Horizontal coupling place
1.6m X 0.8m

Power Supply

0.1 m

Wooden table H=0.8m
470kohm
Resistor

Ground Reference Plane

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 19/45

Test levels: (Apply Level 2 and Level 3)
1a —Contact discharge
Level
Test voltage

1b —Air discharge
Level
Test voltage

(kV)

(kV)

1

2

1

2

2
3

4
6

2
3

4
8

4

8

4

15

X

Special

X

Special

NOTE: “X” is an open level. The level has to be specified in the dedicated equipment specification. If
higher voltages than those shown are specified, special test equipment may be needed.

Test Voltage:
( X ) 4KV contact discharge ( X ) 8KV air discharge
Indirect Discharges: ( X ) HCP
( X ) VCP
Polarity:
( X ) Positive
( X ) Negative
Test mode: Ref. Test method of Chapter 1
Test points: enclosure and connectors of EUT.
Test instruments:
Name
Best Plus BURST ESD
SURGE TRANSIENTS
BEST EMC Test
Instrument

Model Number
Best Plus V6.2

Serial Number
199749-019SC

BEST EMC V2.3
(-8, -9)

199918-006SC

KeyTek Instrument
ESD Test system

Series 2000

9204303/9204310
9209226/9301395

NoiseKen Electrostatic ESS-100L(A)
Discharge Simulator
NoiseKen Electrostatic TC-815P
Discharge Gun

Selected

X

2100C03605
2100C03566

Comment:
Performance Criteria: (According to ETSI EN 301 489-1)
( X ) Enclosure

(

)CT

( X )TT

(

) CR

( X )TR

( X ) Signal and control ports

(

)CT

( X )TT

(

) CR

( X )TR

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 20/45

EN 61000-4-2 PHOTO OF TEST SET-UP

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 21/45

Chapter 5

Radio Frequency Immunity Test (RS)

RS Test inform ation:
Test setup: GTEM cell
Radiated Immunity Test Setup

Model 7122
Isotropic Probe

High Power
Amplifier

GTEMI Cell

EUT

Signal
Generator
EUT Performance
Monitor
Model 7122 Companion
Metering Unit

Modulation
Generator
Model 7110 Data
Processing / Interface Unit

Test levels:

(Apply Level 2)
Level

Test Field Strength
(V/m)

1

1

2
3

3
10

X

Special

NOTE: the “X” is an open test level. This level may be given in the product specification.

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 22/45

Field strength:

( X ) 3V/m at 80 ~ 1000 MHz
( X ) 3 V/m at 1400 ~ 2000 MHz
( ) FM %

Modulation:

( X ) 80% AM Modulation with 1KHz
(
(

( X ) 1% step size
( X ) 2.5 Second

Step size:
Sweep time:
Test mode:

) 80% AM Modulation with 400Hz when signal is modulated at 1kHz
) 900 KHz² 5 KHz with PM 200 Hz and 100% depth

Ref. Test method of Chapter 1

Test instruments:
Name
EMCO GTEM

Model Number
5317

Serial Number
9411-1123

Selected
X

EMCO Probe

7122

9406-1194

X

EMCO METERING UNIT

7122

9406-1194

X

EMCO data interface
HP Personal Computer

7110
D3178A

9410-1273
3438S00486

X
X

HP Signal Generator

8657B

2928U00286

X

HP Signal Generator
IFI Wideband Amplifier

83711A
SMX50

3429A00434
467-0795

X
X

Min-circuit Amplifier

GFL-2500VH

N/A

X

WG radiation meters
WG E-filed

EMC-20
2244 / 90.20

BN2244129
Z-0001

X
X

HP Transmission Test Set

4935A

3115A24046

X

B & K Precision Sound Level Meter

Type 2232

1810564

X

Comment:
Performance Criteria: (According to ETSI EN 301 489-1)
( X ) Enclosure

( X )CT

( )TT

( X ) CR

( )TR

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 23/45

EN 61000-4-3 PHOTO OF TEST SET-UP

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 24/45

Chapter 6

Electric Fast Transient/Burst Requirements Test

EFT Test information:
General test set-up for laboratory type tests:

> 0.25 m
> 0.25 m
> 0.25 m
> 0.25 m

EUT

(L)

(L)
EUT

AC mains
supply

Capacitive
coupling clamp
AC mains
supply

EUT
EUT

0.1 m
0.1 m

Insulating
support

Reference
plane

EFT/Bgenerator (B)

Grounding connection
according to the
manufacturer’ s
specification.
Length to be specified
in the test plan.

Non-metallic
table
EFT/Bgenerator

(L) = length between clamp and EUT to be tested, should
not be more than 1-meter
(A) = location for supply line coupling
(B) = location for signal lines coupling

Coupling / decoupling
network (A)

Reference
plane

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 25/45

Test levels:

(Apply Level 2)

Open-circuit output test voltage (±10%) and repetition rate of the impulses (±20%)
On power supply port, PE
On input/output signal, data and
Level

control ports
Voltage peak

Repetition rate

Voltage peak

Repetition rate

kV

kHz

kV

kHz

1

0.5

5

0.25

5

2

1

5

0.5

5

3

2

5

1

5

4
X

4
Special

2.5
Special

2
Special

5
Special

NOTE: the “X” is an open level. The level has to be specified in the dedicated equipment specification

Test setup: According to EN 61000-4-4
Test Voltage:
DC Power line
( ) 0.5 KV, 5 KH
AC Power line
( X ) 1 KV, 5 KHz
Signal & Control line ( X ) 0.5 KV, 5 KHz; ( ) 1 KV, 5 KHz
Polarity:
( X ) Positive
( X ) Negative
Test Duration: ( X ) 1 minute
( ) 3 minutes
Connected lines: ( ) Power line shielded
( X ) Power line non-shielded
( X ) Signal & Control line non-shielded ( ) Signal & Control line shielded
Test mode: Ref. Test method of Chapter 1.
Test instrument:
Name
Model Number
Best Plus BURST ESD Best Plus V6.2
SURGE TRANSIENTS

Serial Number
199749-019SC

Selected

BEST EMC Test
Instrument

BEST EMC V2.3
(-8, -9)

199918-006SC

KeyTek Instrument
EFT Test system

E412

9505206/505207

X

Comment:
Performance Criteria: (According to ETSI EN 301 489-1)
( X ) Signal and control ports

(

)CT

( X )TT

(

) CR

( X )TR

( ) DC power input ports

(

)CT

( )TT

(

) CR

( )TR

( X ) AC mains input ports

(

)CT

( X )TT

(

) CR

( X )TR

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 26/45

EN 61000-4-4 PHOTO OF TEST SET-UP

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 27/45

Chapter 7

Surge Immunity Test

Surge Test information:
Test setup:

According to EN 61000-4-5

Test levels:

(Apply Level 2 and Level 3)
Level

Test Field Strength
(kV)

1

0.5

2
3

1.0
2.0

4

4.0

X
Special
NOTE: the “X” is an open class. This level may be specified in the product specification.
Test Voltage:

DC Power line ( ) 0.5 KV
AC Power line ( ) Line – Line: 1KV
( ) Line – Ground: 2KV
( X ) Line – Line: 0.5KV
( X ) Line – Ground: 1KV
Control line
( ) 0.5 KV
Signal
( ) 1 KV, ( X ) 0.5KV

Time:

( X ) 1.2/50µs (8/20µs)

Polarity:

( X ) Positive

( X ) Negative

Connected lines: (
) Power line shielded
( X ) Power line non-shielded
( X ) Signal & Control line non-shielded
( ) Signal & Control line shielded
Test mode: Ref. Test method of Chapter 1.

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 28/45

Test instrument:
Name
Model Number
Best Plus BURST ESD Best Plus V6.2

Serial Number
199749-019SC

SURGE TRANSIENTS
BEST EMC Test
BEST EMC V2.3

199918-006SC

Selected

Instrument

(-8, -9)

KeyTek Pulsed-EMI

E103, 501B, E502B,

0008260 ~0008264,

Test System

E503, E505A,
E4552A

0008254

X

Comment:
Performance Criteria: (According to ETSI EN 301 489-1)
( X ) AC mains input ports

(

)CT

( X )TT

(

) CR

( X )TR

( X ) Signal and control ports

(

)CT

( X )TT

(

) CR

( X )TR

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 29/45

EN 61000-4-5 PHOTO OF TEST SET-UP

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 30/45

Chapter 8

Continuous Wave Voltage Immunity Test

CS Test information:
Test setup: According to EN 61000-4-6
Immunity test to RF conducted disturbances:

CDN: Coupling and
decoupling network

Auxiliary
equipment 1

CDN

Equipment
under test

Auxiliary
equipment 1

CDN

0.1 m
support

Ground reference plane
T

T2: Power attenuator
(6dB)

T: Termination 50ohm

T2
RF —generator
Test generator
Test levels: (Apply Level 2)
Frequency range 150kHz to 80MHz
Level

Voltage level (e.m.f.)

1

Uo [dB(µv)]
120

Uo [V]
1

2

130

3

3
X

140

10
Special

NOTE: the “X” is an open test level.

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 31/45

Test Frequency:

( X ) 0.15 ~ 80MHz

Modulation:

(

) FM %

( X ) 80% AM Modulation with 1kHz

Step size:

(
(

) 80% AM Modulation with 400Hz when signal is modulated at 1kHz
) 900 MHz² 5 MHz with PM 200 Hz and 50% duty cycle

(

) Performed over the frequency range 150kHz to 80MHz with the

exception of an exclusion band for transmitters, and for receivers and
duplex transceivers
( X ) For receivers and transmitters the stepped frequency increments shall
be 1% frequency increment of the momentary frequency in the
frequency range 150kHz to 80MHz, unless specified otherwise in the
part of EN 301 489 dealing with the particular type of radio equipment
Field strength:

(

) 1Vrms

( X ) 3Vrms

(

Connected lines:

(
) Power line shielded
( X ) Power line non-shielded
( X ) Signal & Control line non-shielded
(
) Signal & Control line shielded

) 10Vrms

Test mode: Ref. Test method of Chapter 1

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 32/45

Test instruments:
Name

Model Number

Serial Number

Selected

FRANKONIA EMV–Mess–

CIT-10

103A3113

X

System
FRANKONIA CDN

M2+M3

A3011015

X

FRANKONIA CDN

T2-801

A3010002

FRANKONIA CDN
FRANKONIA CDN

T4-801
S1-801

A3015004
A3005002

SCHAFFNER FM-Koppelzange

KEMZ 801

17045

SCHAFFNER RF-SYNTHE
SIZERIAMP21FIER
SCHAFFNER CDN
SCHAFFNER CDN

NSG 2070-1

1020

M325
M216

13773
15604

SCHAFFNER CDN

T004

15230

SCHAFFNER CDN
SCHAFFNER FM-Koppelzange

S501
KEMZ 801

15167
14301

HP Transmission Test Set

4935A

3115A24046

B & K Precision So und Level Meter Type 2232

X

1810564

Comment:
Performance Criteria: (According to ETSI EN 301 489-1)
( ) Antenna port

( )CT

( )TT

( ) CR

( )TR

( X ) Signal and control ports

( X )CT

( )TT

( X ) CR

( )TR

( ) DC power input ports

( )CT

( )TT

( ) CR

( )TR

( X ) AC mains input ports

( X )CT

( )TT

( X ) CR

( )TR

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 33/45

EN 61000-4-6 PHOTO OF TEST SET-UP

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 34/45

Chapter 9

Voltage DIP / Interruption Test

DIP Test information:
Test setup: According to EN 61000-4-11
Voltage dips:

( X ) 30%, 0.01 Second
( X ) 60%, 0.1 Second

Voltage interruptions: ( X ) > 95%, 5 Seconds
Test mode: Ref. Test method of Chapter 1
Test instruments:
Name
Model Number
Best Plus BURST ESD Best Plus V6.2
SURGE TRANSIENTS

Serial Number
199749-019SC

BEST EMC Test
Instrument

BEST EMC V2.3
(-8, -9)

199918-006SC

Partner EMS Tester

Transienter-1000

PIO

Selected

X

Comment:
Performance Criteria: (According to ETSI EN 301 489-1)
Dips 30%:
( X ) CT
( ) TT
( X ) CR
Dips 60%:
( ) CT
( ) TT
( ) CR
Interruptions >95%: ( ) CT
( ) TT
( ) CR
No unintentional responses shall occur at the end of the test;
( )Event of loss of function(s)
( )Event of loss of user stored data

Performance Criteria: (According to ETSI EN 301 489-17)
Dips 60%, 100 ms :
( ) A
( )B
Interruptions >95%, 5 000 ms:
( ) A
( )B

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

( ) TR
( ) TR
( ) TR

(X)C
(X)C

Test Report ------------------------------------------------------------------------------- 35/45

EN 61000-4-11 PHOTO OF TEST SET-UP

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 36/45

Chapter 10 Harmonics Test
Test information:
Test setup:

According to EN 61000-3-2

Test item:
Test mode:

Quasi – stationary & Fluctuating Current Harmonics Test.
Ref. Test method of Chapter 1

Test instrument:
Name
Model Number
Harmonic/Flicker Test HP 6842A
System

Test Equipment Settings:

Serial Number
3531A-00102

Selected
X

Line Voltage

Quasi-stationary Current
Harmonics Test
230VAC

Fluctuating Current
Harmonics Test
230VAC

Line Frequency
Device Class

50Hz
A

50Hz
A

Test Limit Overrides

None

None

Total Number of Failures:

None

None

Total Number of Errors:

None

None

Test Result: Pass

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 37/45

Chapter 11 Voltage Fluctuation and Flicker Test
Test information:
Test setup:

According to EN 61000-3-3

Test mode:

Ref. Test method of Chapter 1

Test instrument:
Name
Model Number
Harmonic/Flicker Test HP 6842A
System

Serial Number
3531A-00102

Selected
X

Test Equipment Settings:
Line Voltage

230VAC

Line Frequency

50Hz

Test Limit Overrides

None

Total Number of Failures:

Pst: (0), Plt: (0)
Dc: (0), Dmax (0), Dt (0)

Total Number of Errors:

None

Test Result: Pass

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 38/45

Chapter 12 Conducted Emission Test
Test condition and setup
All the equipment is placed and setup according to EN 55022.
Mains power:
The EUT is assembled on a wooden table, which is 80 cm high and placed 40 cm from the
back-wall, which is a vertical conducting plane. One LISN is for EUT, the other LISN is for
support equipment. They are all placed on the conductive ground. The EUT’ s LISN connect a
line switch box for selecting L1 or L2, then connect to a preamplifier and spectrum.
The spectrum scans from 150KHz to 30MHz. Conducted emission levels are detected at
maximum peak mode. But if the maximum peak mode failed or over average limit, it will be
measured by average detection mode.
While testing the worst-emission plot printed in the peak detection mode, and there are up
to 6 highest e missions to be recorded. The plot is kept as the original data and not included in the
test report.

List of test Instrument
Calibration Date
Instrument Name

Model No.

Brand

Serial No.

Last time Next time

EMI Receiver
RF Filter Section
LISN (EUT)
LISN (Support E.)
Auto Switch Box
(< 30MHz)

8546A
85460A
LISN-01
LISN-01
ASB-01

HP
HP
TRC
TRC
TRC

3520A00242
3448A00217
9912-03,04
9912-05
9904-01

07/28/03
07/28/03
07/21/03
06/21/03
11/20/02

07/28/04
07/28/04
07/21/04
06/21/04
11/20/03

The level of confidence of 95%, the uncertainty of measurement of conducted emission is +2.43dB / -2.53dB.

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 39/45

Conducted Test Placement (Front view and Side view)

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 40/45

Test Result of Conducted Emissions for Mains power
Test Conditions: Temperature : 25 °C Humidity : 73 % RH
Test Mode: Standby mode
Power

Connected

Conductor Frequency
(KHz)

Line 1

Line 2

Emissions

Class

B

Peak

QP

Average

QP-limit

AVG-limit

Margin

(dBµ V)

(dBµ V)

(dBµ V)

(dBµ V)

(dBµ V)

(dB)

159.000

48.70

---

---

65.74

55.74

-7.04

201.000

45.90

---

---

64.54

54.54

-8.64

257.000

43.12

---

---

62.94

52.94

-9.82

355.000

43.26

---

---

60.14

50.14

-6.88

485.000

40.52

---

---

56.43

46.43

-5.91

668.000

39.73

---

---

56.00

46.00

-6.27

16230.000

43.39

---

---

60.00

50.00

-6.61

17710.000

42.66

---

---

60.00

50.00

-7.34

20200.000

41.89

---

---

60.00

50.00

-8.11

23120.000

40.41

---

---

60.00

50.00

-9.59

118.640

52.90

49.17

25.26

65.86

55.86

-16.69

180.000

50.79

---

---

65.14

55.14

-4.35

229.000

48.66

---

---

63.74

53.74

-5.08

373.710

47.06

40.17

24.80

59.91

49.91

-19.74

401.390

45.83

39.63

23.87

57.37

47.37

-17.74

507.550

44.79

38.15

22.42

56.00

46.00

-17.85

603.500

44.50

37.43

20.44

56.00

46.00

-18.57

767.000

42.96

---

---

56.00

46.00

-3.04

16160.000

43.00

---

---

60.00

50.00

-7.00

17710.000

43.13

---

---

60.00

50.00

-6.87

*The reading amplitudes are all under limit.

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 41/45

Test Conditions: Temperature : 25 °C Humidity : 73 % RH
Test Mode: Linking mode
Power

Connected

Conductor Frequency
(KHz)

Line 1

Line 2

Emissions

Class

B

Peak

QP

Average

QP-limit

AVG-limit

Margin

(dBµ V)

(dBµ V)

(dBµ V)

(dBµ V)

(dBµ V)

(dB)

118.340

52.87

44.56

10.90

65.63

55.63

-21.07

212.000

49.75

---

---

64.23

54.23

-4.48

271.000

46.99

---

---

62.54

52.54

-5.55

365.810

47.38

38.21

24.84

60.03

50.03

-21.82

368.790

46.53

38.33

23.92

58.11

48.11

-19.78

421.680

46.14

36.56

23.92

56.83

46.83

-20.27

617.050

44.59

33.08

23.45

56.00

46.00

-22.92

802.000

42.16

---

---

56.00

46.00

-3.84

18240.000

35.05

---

---

56.00

46.00

-10.95

23120.000

39.82

---

---

60.00

50.00

-10.18

163.000

48.58

---

---

65.63

55.63

-7.05

197.000

46.18

---

---

64.66

54.66

-8.48

231.000

44.61

---

---

63.69

53.69

-9.08

267.000

42.81

---

---

62.66

52.66

-9.85

366.000

43.83

---

---

59.83

49.83

-6.00

426.000

41.67

---

---

58.11

48.11

-6.44

490.000

40.93

---

---

56.29

46.29

-5.36

731.000

39.65

---

---

56.00

46.00

-6.35

19620.000

35.84

---

---

60.00

50.00

-14.16

26540.000

39.35

---

---

60.00

50.00

-10.65

*The reading amplitudes are all under limit.

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 42/45

Chapter 13 Radiated Emission Test
Test condition and setup
Pretest:

Prior to the final test (OATS test), the EUT is placed in a shielded enclosure,

and scan from 30MHz to 1GHz. This is done to ensure the radiation is exactly emitted from the
EUT. Final test: Final radiation measurements are made on a 10 – meter, open-field test
site. The EUT is placed on a nonconductive table, which is 0.8m height, the top surface is 1.0 x
1.5 meter. The entire placement is according to EN 55022.
The whole range antenna is used to measure frequency from 30 MHz to 1GHz. The final
test is used the spectrum analyzer (EMI Receiver). Measure more than six top marked
frequencies generated form pretest by computer step by step at each frequency.
The EUT is rotated 360 degrees, and antenna is raised and lowered from 1 to 4 meters to
find the maximum emission levels. The antenna is used with both horizontal and vertical
polarization. Appropriated preamplifier which is made by TRC is used for improving sensitivity
and precautions is taken to avoid overloading .The spectrum analyzer’ s 6dB bandwidth is set to
120 kHz, and the EUT is measured at quasi-peak (below 1GHz) mode.
If the emission is close to the frequency band of ambient, the tester will recheck the data
and the corrected data will be written in the test data sheet. If the emission is just within the
ambient, the data from shielded room will be taken as the final data.

List of test Instrument
Calibration Date
Instrument Name Model No.
Brand
Serial No.
Receiver
SCR3102
SCHAFFNER 021
Control box
TWR95-4
TRC
C9001-2
Antenna
CBL6141A
SCHAFFNER 4206
Pre-amplifier
TRC-CB-2
TRC
CB-002
Jyebao
CL-002
Coixal cable (20m) RG-214/U
CL-002
Coixal cable (50cm) BNC31VB-0316 Jyebao
CL-007
Coixal cable (20cm) BNC31VB-0318 Jyebao
CL-006
Coixal cable (55cm) BNC31VB-0316 Jyebao
CL-005
Coixal cable (55cm) BNC31VB-0316 Jyebao
Open test side (Antenna, Amplify, cable calibrated together)

Last time
04/22/03
None
05/27/03
05/29/03
05/29/03
05/29/03
05/29/03
05/29/03
05/29/03
05/15/03

Next time
04/22/04
None
05/27/04
05/29/04
05/29/04
05/29/04
05/29/04
05/29/04
05/29/04
05/15/04

The level of confidence of 95% , the uncertainty of measurement of radiated emission is +2.85d B / -2.77dB.

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 43/45

Radiated Test Placement (Front view and Side view)

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 44/45

Test Result of Spurious Radiated Emissions
Test Conditions: Temperature : 25 ° C

Humidity : 73 % RH

Test Mode: Linking mode, Horizontal
Radiated
Emission
Table
( ± )

Frequency Amplitude Ant. H.
(m)
(MHz)
(dBµ V)

Correction

Corrected

Factors

Amplitude

(dB)

Class B
( 10 m )

Limit
(dBµ V/m) (dBµ V/m)

Margin
(dB)

205.3338

29.17

2.50

326

-3.85

25.32

30.00

-4.68

250.0163

33.50

2.50

359

-1.80

31.70

37.00

-5.30

308.0000

32.20

2.50

308

-0.99

31.21

37.00

-5.79

425.0288

28.46

2.50

218

5.10

33.56

37.00

-3.44

475.0275

24.22

2.50

18

6.20

30.42

37.00

-6.58

Test Mode: Linking mode, Vertical
Radiated
Emission
Frequency Amplitude Ant. H.
(MHz)
(dBµ V)
(m)

Table
( ± )

Correction

Corrected

Factors

Amplitude

(dB)

Class B
( 10 m )

Limit
(dB
µ V/m)
(dBµ V/m)

Margin
(dB)

30.2700

19.57

1.00

118

4.79

24.36

30.00

-5.64

124.4638

30.95

2.51

359

-4.73

26.22

30.00

-3.78

205.5685

27.62

2.51

324

-3.84

23.78

30.00

-6.22

250.0163

37.66

1.00

170

-1.80

35.86

37.00

-1.14

410.6675

28.53

2.51

105

4.81

33.34

37.00

-3.66

Note:
1. Margin = Amplitude – limit, if margin is minus means under limit.
2. Corrected Amplitude = Reading Amplitude + Correction Factors
3. Correction factor = Antenna factor + ( Cable Loss – Amplitude gain)

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440

Test Report ------------------------------------------------------------------------------- 45/45

Appendix A
Brand name and Model name List
Brand Name

Model Name

TRENDware

TEW-231BRP

Report No.: C51ET385 (ETSI EN 301489)
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 46
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:5fc645db-0e54-4983-8984-3ebb3e97df59
Modify Date                     : 2004:03:25 14:07:36-08:00
Create Date                     : 2004:03:25 13:49:27-08:00
Metadata Date                   : 2004:03:25 14:07:36-08:00
Document ID                     : uuid:ad7ee6a3-8cbc-4d63-9195-7874e6fd21fe
Format                          : application/pdf
Title                           : Microsoft Word - Application Form.doc
Creator                         : ADOBEPS4.DRV Version 4.50
Author                          : weng
Producer                        : Acrobat Distiller 5.0.5 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu