These robust IP rated standalone keypads are designed to
operate in both internal and external environments.
EX5 Keypads include backlit metallic or plastic keys with a
choice of plastic or metal housings (surface or flush).
They incorporate an easy to follow programming menu
allowing up to 99 unique codes and the setting of relay
output times. The units also include inputs to trigger the
relay from a push to exit button.
Both audible and visual indication is standard indicating
that a code is correct or incorrect while also helping to
navigate through the programming menu.

Technical Characteristics
Codes:
Relays:
Relay Time:
IP Rating
Power:
Current:

99 User Codes (1 - 8 digits)
2 Relays - R1: (10A @ 24v DC / 120v AC) R2: (2A @ 24v AC/DC)
1 - 99 Seconds or latching (00)
IP65
12/24v AC/DC
Standby 30mA / Maximum 130mA

Dimensions
90mm

105mm

140mm

102

120mm

43
52/72

40mm

1

EX5

Installation Instructions
ABS Housing Surface

43
1.

2.

Cable

3.

4.

7.

8.

Cable

30mm

Ø6.0

30mm

Ø6.0

5.

6.

3 (8 x 30 CSK)
2 (M3 x 6mm)
security screw

Metal Housing Surface

52/ 72
1.

4.

3.

2.

5
5

5.

6.

7.

3 (8 x 30mm CSK)
2 (M3 x 6mm)

2

EX5

Metal Housing Flush

102
1.

3.

2.

4.

Cable

30mm

Ø6.0

5.

6.

7.

3 (8 x 30mm CSK)
4 (M3 x 6mm)

Terminal Connections

Terminals

Tamper switch

Master code reset
jumper

12/24V AC/DC
12/24V AC/DC
PB1
GND
PB2
+LG
-LG
NC
Relay 1 C
NO
+LR
-LR
+9V
CODIX DATA
BUS
GND
TAMP
TAMP
NC
Relay 2 C
NO

3

Voltage in
Push to exit input 1 (Active GND)
Push to exit ground
Push to exit input 2 (Active GND)
+ Green LED
- Green LED
Normally closed
Common
Normally open
+ Red LED
- Red LED
Connections for CODIX peripherals
Tamper switch output (Normally closed)
Normally closed
Common
Normally open

EX5

12v DC Wiring Diagram

12 DC
PSU

+ 12/24V
AC/DC

LR

+
+9V
DATA
GND
TAMP
TAMP
NC
C
NO

PTE
(Normally Open)

Relay 2

Relay 1

LR

BUS

PB1
GND
PB2
+
NC
C
NO

IN4002

12v AC Wiring Diagram
12 AC
PSU

PTE
(Normally Open)

IN4002

12/24V
AC/DC

LR

+
+9V
DATA
GND
TAMP
TAMP
NC
C
NO

Relay 2

Relay 1

LR

BUS

PB1
GND
PB2

IN4002

+
NC
C
NO

100nF

4

EX5

24v DC Wiring Diagram

24 DC
PSU

+ -

1KΩ / 1W

12/24V
AC/DC

LR

+
+9V
DATA
GND
TAMP
TAMP
NC
C
NO

PTE
(Normally Open)

Relay 2

Relay 1

LR

BUS

PB1
GND
PB2

1KΩ / 1W

+
NC
C
NO

IN4002

24v AC Wiring Diagram
24 AC
PSU
IN4002

12/24V
AC/DC

LR

+
+9V
DATA
GND
TAMP
TAMP
NC
C
NO

LR

BUS

PB1
GND
PB2

Relay 2

Relay 1

1KΩ / 1W

PTE
(Normally Open)

1KΩ / 1W

+
NC
C
NO

IN4002

100nF

5

EX5

Adding a User Code

Relay Time

Enter Master Code
(Factory Default = 000)
Followed by B

Enter Master Code
(Factory Default = 000)
Followed by B

Yellow LED on

Yellow LED on

Press 0

Enter  (1 or 2)

Enter  (01-99)
(Up to 99 codes may be added)

Enter  (01-99)
(Enter 00 if latch mode required)

Enter  (1-8 digits)

Press A

Press A
More Yes
relays?

Press 3 + 

No
Yellow LED off

Enter  to be triggered
[1=Relay 1] [2=Relay 2] [12=Relays 1 & 2]

Press B to exit programming

Press A

More
codes?

Yes

Delete a User Code

No
Yellow LED off

Press B to exit programming

Enter Master Code
(Factory Default = 000)
Followed by B
Yellow LED on

Press 9

Delete All Codes

Enter  (01-99)
to delete

Enter Master Code
(Factory Default = 000)
Followed by B

Press A

Yellow LED on

Press 8

More
codes?

Press 99

Yes

No
Yellow LED off

Press B to exit programming

Press A
Yellow LED off

Press B to exit programming

6

EX5

Resetting the Master Code

(P 3)

(P 3)

Disconnect power and close jumper P3.
Reconnect power.
Beep Beep + Yellow LED blinks

(P 3)

000
2578
A
B

(P 3)

Remove jumper P3.
Yellow LED switches on + Long beep

Enter
Enter
Press
Press

the default master code 000
the new master code e.g 2578
A followed by Beep Beep
B and the yellow LED switches off

Troubleshooting
Keypad does not respond to key presses
1. Check the correct voltage is present on the input terminals (12/24v ac/dc).
Keypad is not accepting default master code 000
1. Perform master code reset.
Keypad no longer accepts user code
1. Check master code has been changed from the default.
2. Check back EMF protection across lock release.
Keypad accepts user code but no longer releases lock
1. Check the correct relay output is assigned to user code.
2. Check all push to exit buttons are normally open.
3. Check for continuity across relay contacts when user code is entered.
4. Check lock wiring for continuity.
5. Check the correct voltage is present on the input terminals (12/24v ac/dc).
Red / Green LED not functioning
1. Check LR & LG wiring
2. Check a resistor / diode is present if required.
Relay triggers and does not return back to its previous state
1. Check relay is not set up to latch

7

EX5

Northern Office
Videx Security Ltd
Unit 4-7 Chillingham ind Est
Newcastle Upon Tyne
NE6 2XX
Tel: 0870 300 1240
Fax: 0191 224 5678
Southern Office
1 Osprey
Trinity Park
Trinity Way
London
E4 8TD
Fax: 0208 523 5825
Technical Support
tech@videx-security.com
Tel: 0191 224 3174
Fax: 0191 224 4938
http://www.videx-security.com

8

EX5



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 8
Create Date                     : 2011:03:29 10:21:59Z
Modify Date                     : 2011:03:29 10:21:59Z
Producer                        : Corel PDF Engine Version 15.2.0.661
Author                          : Aaron Houghton
Creator                         : CorelDRAW X5
Title                           : EX5.cdr
EXIF Metadata provided by EXIF.tools

Navigation menu