EX5 Videx Keypad Technical Manual
EX5 EX5
User Manual: Videx EX5 Keypad Technical manual
Open the PDF directly: View PDF
.
Page Count: 8
| Download | |
| Open PDF In Browser | View PDF |
These robust IP rated standalone keypads are designed to operate in both internal and external environments. EX5 Keypads include backlit metallic or plastic keys with a choice of plastic or metal housings (surface or flush). They incorporate an easy to follow programming menu allowing up to 99 unique codes and the setting of relay output times. The units also include inputs to trigger the relay from a push to exit button. Both audible and visual indication is standard indicating that a code is correct or incorrect while also helping to navigate through the programming menu. Technical Characteristics Codes: Relays: Relay Time: IP Rating Power: Current: 99 User Codes (1 - 8 digits) 2 Relays - R1: (10A @ 24v DC / 120v AC) R2: (2A @ 24v AC/DC) 1 - 99 Seconds or latching (00) IP65 12/24v AC/DC Standby 30mA / Maximum 130mA Dimensions 90mm 105mm 140mm 102 120mm 43 52/72 40mm 1 EX5 Installation Instructions ABS Housing Surface 43 1. 2. Cable 3. 4. 7. 8. Cable 30mm Ø6.0 30mm Ø6.0 5. 6. 3 (8 x 30 CSK) 2 (M3 x 6mm) security screw Metal Housing Surface 52/ 72 1. 4. 3. 2. 5 5 5. 6. 7. 3 (8 x 30mm CSK) 2 (M3 x 6mm) 2 EX5 Metal Housing Flush 102 1. 3. 2. 4. Cable 30mm Ø6.0 5. 6. 7. 3 (8 x 30mm CSK) 4 (M3 x 6mm) Terminal Connections Terminals Tamper switch Master code reset jumper 12/24V AC/DC 12/24V AC/DC PB1 GND PB2 +LG -LG NC Relay 1 C NO +LR -LR +9V CODIX DATA BUS GND TAMP TAMP NC Relay 2 C NO 3 Voltage in Push to exit input 1 (Active GND) Push to exit ground Push to exit input 2 (Active GND) + Green LED - Green LED Normally closed Common Normally open + Red LED - Red LED Connections for CODIX peripherals Tamper switch output (Normally closed) Normally closed Common Normally open EX5 12v DC Wiring Diagram 12 DC PSU + 12/24V AC/DC LR + +9V DATA GND TAMP TAMP NC C NO PTE (Normally Open) Relay 2 Relay 1 LR BUS PB1 GND PB2 + NC C NO IN4002 12v AC Wiring Diagram 12 AC PSU PTE (Normally Open) IN4002 12/24V AC/DC LR + +9V DATA GND TAMP TAMP NC C NO Relay 2 Relay 1 LR BUS PB1 GND PB2 IN4002 + NC C NO 100nF 4 EX5 24v DC Wiring Diagram 24 DC PSU + - 1KΩ / 1W 12/24V AC/DC LR + +9V DATA GND TAMP TAMP NC C NO PTE (Normally Open) Relay 2 Relay 1 LR BUS PB1 GND PB2 1KΩ / 1W + NC C NO IN4002 24v AC Wiring Diagram 24 AC PSU IN4002 12/24V AC/DC LR + +9V DATA GND TAMP TAMP NC C NO LR BUS PB1 GND PB2 Relay 2 Relay 1 1KΩ / 1W PTE (Normally Open) 1KΩ / 1W + NC C NO IN4002 100nF 5 EX5 Adding a User Code Relay Time Enter Master Code (Factory Default = 000) Followed by B Enter Master Code (Factory Default = 000) Followed by B Yellow LED on Yellow LED on Press 0 Enter(1 or 2) Enter (01-99) (Up to 99 codes may be added) Enter (01-99) (Enter 00 if latch mode required) Enter (1-8 digits) Press A Press A More Yes relays? Press 3 + No Yellow LED off Enter to be triggered [1=Relay 1] [2=Relay 2] [12=Relays 1 & 2] Press B to exit programming Press A More codes? Yes Delete a User Code No Yellow LED off Press B to exit programming Enter Master Code (Factory Default = 000) Followed by B Yellow LED on Press 9 Delete All Codes Enter (01-99) to delete Enter Master Code (Factory Default = 000) Followed by B Press A Yellow LED on Press 8 More codes? Press 99 Yes No Yellow LED off Press B to exit programming Press A Yellow LED off Press B to exit programming 6 EX5 Resetting the Master Code (P 3) (P 3) Disconnect power and close jumper P3. Reconnect power. Beep Beep + Yellow LED blinks (P 3) 000 2578 A B (P 3) Remove jumper P3. Yellow LED switches on + Long beep Enter Enter Press Press the default master code 000 the new master code e.g 2578 A followed by Beep Beep B and the yellow LED switches off Troubleshooting Keypad does not respond to key presses 1. Check the correct voltage is present on the input terminals (12/24v ac/dc). Keypad is not accepting default master code 000 1. Perform master code reset. Keypad no longer accepts user code 1. Check master code has been changed from the default. 2. Check back EMF protection across lock release. Keypad accepts user code but no longer releases lock 1. Check the correct relay output is assigned to user code. 2. Check all push to exit buttons are normally open. 3. Check for continuity across relay contacts when user code is entered. 4. Check lock wiring for continuity. 5. Check the correct voltage is present on the input terminals (12/24v ac/dc). Red / Green LED not functioning 1. Check LR & LG wiring 2. Check a resistor / diode is present if required. Relay triggers and does not return back to its previous state 1. Check relay is not set up to latch 7 EX5 Northern Office Videx Security Ltd Unit 4-7 Chillingham ind Est Newcastle Upon Tyne NE6 2XX Tel: 0870 300 1240 Fax: 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD Fax: 0208 523 5825 Technical Support tech@videx-security.com Tel: 0191 224 3174 Fax: 0191 224 4938 http://www.videx-security.com 8 EX5
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 8 Create Date : 2011:03:29 10:21:59Z Modify Date : 2011:03:29 10:21:59Z Producer : Corel PDF Engine Version 15.2.0.661 Author : Aaron Houghton Creator : CorelDRAW X5 Title : EX5.cdrEXIF Metadata provided by EXIF.tools