SL 2 Technical Practice Viking LED Strobe/Beacon Visual Indicator Information Strobe Beacon Tech Info
User Manual: Viking SL-2 LED Strobe/Beacon Visual Indicator Technical Information VIKING System Other Products
Open the PDF directly: View PDF .
Page Count: 4
Download | ![]() |
Open PDF In Browser | View PDF |
TECHNICAL Practice Practice TELECOM SOLUTIONS FOR THE SL-2 LED Strobe/Beacon Visual Indicator 2 1 S T C E N T U RY April 2, 2012 LED Strobe and/or Beacon Visual Indicator with Programmable Brightness and Flash Patterns The SL-2 is a 360° LED Strobe and/or Beacon visual indicator. LED’s not only are more efficient and last longer than standard flash tubes but are also immune to shock and vibration. The LED’s are internally positioned to allow a 360° viewing angle when the unit is mounted vertically and a 120° viewing angle when side mounted. The SL-2 can be user programmed to output 4 different flash patterns: Single Flash, Double Flash, Quad Flash or Flicker Flash. The unit can also be programmed as a continuous-On Beacon only, Strobe only or Beacon/Strobe allowing a lower intensity beacon to remain on and a high intensity strobe to be activated by a contact closure. 6 different brightness levels are also programmable for the Beacon and the Strobe. All programming is stored in non-volatile memory so you won’t lose the programming when the unit is powered down, allowing you to program units prior to installation. The SL-2 is designed for indoor applications and comes standard with a Blue shatter resistant polycarbonate lens. Optional Red, Amber and Clear lenses are sold separately (go to www.vikingelectronics.com and click on spare parts). Unit surface mounts to wall, post, panel, 4” electrical box or wet location electrical box round lamp holder cover. Features Applications • Over 57,000 hour (6.5 year) light source life to 70% light output • High noise level area’s where visual status is required • 4 Programmable Flash Patterns • Signal personnel of equipment malfunctions • 6 Programmable Beacon and Strobe brightness settings • Warn personnel they are entering a restricted area • Immune to shock and vibration • Low current draw • Shatter resistant polycarbonate lens Phone...715.386.8861 info@vikingelectronics.com h t t p : / / w w w. v i k i n g e l e c t r o n i c s . c o m Specifications Power: 10- 15VDC 0.90 Amp (Peak), 0.15 Amp (Avg) @ 15VDC Dimensions: 112mm diameter x 70mm (4.41" diameter x 2.76") Shipping Weight: 0.25 kg (0.6 lbs) Environmental: -40°C to 60°C (-40°F to 125°F) Strobe Intensity: xxxx Lumen (max. setting) Strobe Flash Rate: 60 flashes per minute (default) see Strobe Flash Patterns page 4 Beacon Intensity: xxxx Lumen (maximum setting) LED Life: >57,000 hours to 70% LED light output Connections: Three 9" (22.9 cm) long leads, 26 AWG IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, PLEASE CONTACT: VIKING TECHNICAL SUPPORT AT (715) 386-8666 Our Technical Support Department is available for assistance Monday 8am - 4pm, Tuesday to Friday 8am - 5pm central time. So that we can give you better service, before you call please: 1. Know the model number, the serial number and what software version you have (see serial label). 2. Have your Technical Practice in front of you. 3. It is best if you are on site. RETURNING PRODUCT FOR REPAIR RETURNING PRODUCT FOR EXCHANGE The following procedure is for equipment that needs repair: 1. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number. The customer MUST have a complete description of the problem, with all pertinent information regarding the defect, such as options set, conditions, symptoms, methods to duplicate problem, frequency of failure, etc. 2. Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. Static sensitive equipment such as a circuit board should be in an anti-static bag, sandwiched between foam and individually boxed. All equipment should be wrapped to avoid packing material lodging in or sticking to the equipment. Include ALL parts of the equipment. C.O.D. or freight collect shipments cannot be accepted. Ship cartons prepaid to: Viking Electronics, 1531 Industrial Street, Hudson, WI 54016 3. Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a PO Box. 4. RA number on carton: In large printing, write the R.A. number on the outside of each carton being returned. The following procedure is for equipment that has failed out-of-box (within 10 days of purchase): 1. Customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer MUST be able to step through recommended tests for diagnosis. 2. If the Technical Support Product Specialist determines that the equipment is defective based on the customer's input and troubleshooting, a Return Authorization (R.A.) number will be issued. This number is valid for fourteen (14) calendar days from the date of issue. 3. After obtaining the R.A. number, return the approved equipment to your distributor, referencing the R.A. number. Your distributor will then replace the product over the counter at no charge. The distributor will then return the product to Viking using the same R.A. number. 4. The distributor will NOT exchange this product without first obtaining the R.A. number from you. If you haven't followed the steps listed in 1, 2 and 3, be aware that you will have to pay a restocking charge. LIMITED WARRANTY Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of one year from the date of purchase from any authorized Viking distributor or 18 months from the date manufactured, which ever is greater. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.) number. This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence or any damage caused by use of the product by the purchaser or others. This warranty does not cover non-EWP products that have been exposed to wet or corrosive environments. NO OTHER WARRANTIES. VIKING MAKES NO WARRANTIES RELATING TO ITS PRODUCTS OTHER THAN AS DESCRIBED ABOVE AND DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCLUSION OF CONSEQUENTIAL DAMAGES. VIKING SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO PURCHASER, OR ANY OTHER PARTY, FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR EXEMPLARY DAMAGES ARISING OUT OF OR RELATED TO THE SALE OR USE OF THE PRODUCT SOLD HEREUNDER. EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY. WHETHER IN AN ACTION BASED ON CONTRACT, TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY) OR ANY OTHER LEGAL THEORY, ANY LIABILITY OF VIKING SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT, OR AT VIKING'S OPTION, REFUND OF THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND ANY LIABILITY OF VIKING SHALL BE SO LIMITED. IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER OF WARRANTIES, EXCLUSION OF CONSEQUENTIAL DAMAGES, AND EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY, ARE SEVERABLE FROM ANY OTHER PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH. Installation A. Mounting the SL-2 (Drill Template shown at actual size.) B. Wiring the SL-2 Strobe Only Red Green Black Beacon Only Red + 12VDC Green * Black - GND In programming, select programming feature 2 (strobe only). When the switch/contact is activated, the strobe will flash for the duration of the contact closure. * Note: Switch / dry contact closure with a minimum contact rating of 25mA @ 15VDC. Beacon / Strobe Red + 12VDC or Green * Black - GND In programming, select programming feature 3 (beacon only). With the green wire connected to the red wire, when power is applied the steadyon beacon will turn on. An optional low current switch or contact can be used between the green and red wire to turn the beacon on or off. + 12VDC * - GND In programming, select programming feature 1 (beacon/strobe, factory default). When power is applied the lower intensity steady-on beacon will light. When the switch/contact is activated, the beacon will turn off and the strobe will flash for the duration of the contact closure. Programming The SL-2 can be user programmed as a Beacon only, Strobe only or Beacon/Strobe. The brightness setting can be programmed separately for the Strobe or Beacon and one of 4 different Flash Patterns can be programmed for the Strobe (See Strobe Flash Patterns, section D). A. Accessing the Programming Mode (Optional, the SL-2 is factory programmed to the Beacon/Strobe Mode and brightest Beacon/Strobe settings). Step 1. Apply 10-15 VDC power to the Red (+) and Black (-) wires. Touch and hold the Green (Control) wire to the Black (-) wire for 3 seconds. The strobe should flash twice. You are now in Programming mode. Note: Once in the programming mode, if a programming command Step 2. has not been entered for 20 seconds the strobe will flash 3 times indicating the unit has exited programming and returned to the Run Mode. B. Programming Desired Features (after accessing Programming Mode above) Select the Feature: Momentarily touch the Green (Control) wire to the Black (-) wire 1 to 10 times to select which feature to program (see Programming Features List, section C). The strobe should momentarily flash each time the Green (Control) wire has touched the Black (-) wire. Features 1-3 & 6-10: After selecting Programming Features 1-3 or 6-10, wait 3 seconds and the strobe should flash 2 times indicating that feature has been programmed. You can now exit programming or move on to programming the Beacon or Strobe brightness settings. Setting Strobe Brightness (factory set to 6/Brightest): After selecting Programming Feature 4 (Strobe Brightness), wait 3 seconds and the strobe should begin flashing in the preprogrammed flash pattern. Touch and hold the Green (Control) wire to the Black (-) wire. The SL-2 will begin flashing the strobe cycling through 6 different brightness settings from lowest to highest. When the SL-2 flashes at the desired brightness level immediately remove the Green wire from the Black. The SL-2 should flash twice indicating the selected brightness level has been set. Setting Beacon Brightness (Factory set to 6/Brightest): After selecting Programming Feature 5 (Beacon Brightness), wait 3 seconds and the beacon will light at its preprogrammed beacon brightness setting. Touch and hold the Green (Control) wire to the Black (-) wire. The SL-2 will begin stepping through 6 different beacon brightness settings from lowest to highest. When the SL-2 lights at the desired beacon brightness level immediately remove the Green wire from the Black. The SL-2 should flash twice indicating the selected brightness level has been set. Exiting Programming: To exit programming simply wait 20 seconds from the last programming command and the unit will flash 3 times. This indicates the SL-2 has exited the programming mode and is now in the Run mode. Note: To eliminate waiting 20 seconds, you can also exit programming after the last programming command by touching and holding the Green (Control) wire to the Black (-) for 3 seconds. The strobe will flash 3 times indicating the unit has exited the programming mode and is now in the Run mode. C. Programming Features List Feature # : Description: 1 Beacon/Strobe (factory default) 2 Strobe Only 3 Beacon Only 4 Strobe Brightness 1-6 (factory default = 6/Brightest setting) 5 Beacon Brightness 1-6 (factory default = 6/Brightest setting) 6 Single Flash Strobe (factory default) 7 Double Flash Strobe 8 Quad Flash Strobe 9 Flicker Flash Strobe 10 Reset to Factory Default Settings D. Strobe Flash Patterns 0.80 sec 0.20 sec Repeat Single Flash: ON 0.10 sec OFF 0.10 sec 0.10 sec 0.80 sec Repeat Double Flash: ON OFF OFF ON 0.10 sec 0.05 sec 0.80 sec Repeat Quad Flash: ON 0.025 sec Typ. OFF ON OFF ON OFF OFF ON 0.025 sec Typ. 0.80 sec ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON Repeat Flicker Flash: OFF 8 Pulses Product Support Line...715.386.8666 Fax Back Line...715.386.4345 Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes. DOD# XXX Printed in the U.S.A. ZF303300 Rev 4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Extract, Print high-res XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2012:04:04 10:55:22-05:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2012:04:04 11:06:21-05:00 Metadata Date : 2012:04:04 11:06:21-05:00 Format : application/pdf Title : SL-2 Technical Practice Creator : Viking Electronics, Inc. Description : LED Strobe/Beacon Visual Indicator Document ID : uuid:fad08038-36d3-4271-bc10-a197ff757828 Instance ID : uuid:4d4f8ae1-a864-467c-802b-53393db5727b Page Count : 4 Subject : LED Strobe/Beacon Visual Indicator Author : Viking ElectronicsEXIF Metadata provided by EXIF.tools