DYNATORQUE Valve Magazine Fall 2002 Article
User Manual: DYNATORQUE Valve Magazine Fall 2002 Article Resource Library
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
FALL 2002 VOLUME 14, NO. 4 M A G A Z I N E Advances in Valve & Actuator Technologies FALL 2002 190697klc 1 2/25/03, 2:06 PM 1 CONSIDER Mechanical Partial S FOR PROCESS ESD by Mike Mitchell 2 190697klc T here is a storm forming on the horizon for offshore rigs, refineries, and all other industrial process plants that have automated valves in their safety systems. Like the rumble of distant thunder, they know it is coming—but they’re just now cranking-up their radar to find out how the storm will affect them. One thing is certain: when this storm finally hits, no plant will remain untouched by its fury....What’s causing the storm to brew? In “the good old days” process plant operations managers had the luxury of shutting down their facility every year or two for what is now fondly remembered as the “maintenance shutdown”. This was a period of time set aside to close down production and perform maintenance on the plant’s equipment. So the production stream was “turned off” and the maintenance crew was free to disassemble, clean and/or replace equipment. The control systems engineer, safety engineer, and reliability engineers were able to test their process control and safety equipment without the worry of dealing with process flow. That was when companies could devote the time and resources to perform this task in the most efficient and complete manner. Times have changed, and to succeed in today’s aggressive business climate, we must change along with the times. One of the most obvious changes in the process industries in recent years is the demise of the planned periodical maintenance shutdown. Closing down the plant, for whatever reason, also shuts down the revenue stream. The process industries are under incredible pressure to increase revenues and these “shutdowns” of the revenue flow are not acceptable to management and other stakeholders. The result is an emphasis on running industrial process plants on a 24-hour-a-day, 7-day-a-week basis for as many years as possible-without maintenance shutdowns. VA LV E M A G A Z I N E 2 2/25/03, 2:07 PM ERING al Stroke Test Devices &Safety-Related Valves Among the most critical valves affected by less frequent maintenance are the Emergency Shutdown (ESD) Valves and other fail-safe valves in safety related applications. These valves may typically incorporate a spring-to-fail actuator to stroke a valve in the event of an upset process condition. If the ESD valve does not perform its function to close (or in rare applications, open the valve) at the time of an upset event, the consequences to property and life can be catastrophic. [Note: For the purpose of simplifying this discussion, when referring to pneumatically or hydraulically operated ESD and safety valves, the convention of “air-to-open valve, spring-to-close valve, de-energize to trip” will be used]. This new emphasis on continual process revenue generation has led the Occupational Safety and Health Administration (OSHA), insurance companies, other regulatory agencies, and safety engineers to take a fresh look at how this new operating philosophy impacts plant safety. These agencies posed the question to the process plants: If the plant is going to remain operational for an extended period of time, how can we be assured the valve safety systems will function correctly when called upon? The industry has responded to this question with “accepted industry standards” (essentially self-governing) such as ISAS84.01 (Application of Safety Instrumented Systems for the Process Industries) and IEC 61508 (Functional Safety Of E/E/ PE Safety-Related Systems) to determine acceptable levels of performance of these systems. This article examines mechanical Partial Stroke Test Devices as a preferred methodology for assuring compliance with new standards. These standards define requirements for Safety Instrumented Systems (SIS) and allow the end user to establish Safety Integrity Levels (SIL) for specific applications. One means of showing conformance is to test all the various SIS components such as solenoid valves, quick exhaust valves, relays, valve to stem integrity, and valve actuator without actually closing the valve. By the nature of the application, the ESD valve is subject to flowing process fluid. If the ESD were to be full-stroke tested while the plant is operational, the “flow of revenue” (i.e., process flow) would come to a halt. One methodology of overcoming this dilemma is to install a bypass valve and piping around the ESD valve. When the bypass valve is open, the ESD valve and its safety system may be fully tested without affecting process flow. This option sounds effective, and it is. However, piping dimensional constraints (particularly on offshore drilling and production rigs) and the cost associated with installing a dual system at every ESD valve make a bypass system generally not preferred. FALL 2002 190697klc 3 2/28/03, 8:32 AM 3 One of the terms associated with these ISA and IEC standards is “partial stroke testing” (Reference ISA-S84.01, paragraph 9.7.5.2.b). A “partial stroke” might be defined as, for example, allowing the safety system to close a valve only 20% (this would be the set point). In that case, all of the control elements are being tested, but obviously the valve never fully closes during the test. The overall assumption is that a given number of “partial strokes” can be applied as a statistical “credit” against “full stroke tests”. Thus, the end user may be capable of either 1) lowering the Probability of Failure on Demand (PFD) of a given SIS by doing partial stroke tests between full stroke tests; or 2) by doing partial stroke testing between full stroke tests, the end user may be able to maintain or lower his PFD and enjoy a greater interval of time between full stroke test intervals. The background for safety testing has been explained in a previous Valve Magazine (See “Getting Closure on Compliance, Putting Valve-Related Safety Standards in Perspective”, Valve Magazine, Summer 2002 Edition, Volume 14, Number 3). The technical analysis supporting the benefits of Partial Stroke Testing have also been examined in detail at VMA Seminars (Reliability, Safety, Integrity Today, March 7-8, 2002, Houston, TX), and ISA conferences (Safety Instrumented Systems for the Process Industry, May 14-16, 2002, Baltimore, MD) and numerous websites (see, for example, www.iec.ch/zone/fsafety/; www.instrument-net.co.uk/silansi.htm). Thus, it would be redundant to cover that material here. The purpose of this discussion is to examine the benefits of mechanical Partial Stroke Test Devices as a preferred methodology for functional testing of the SIS when a full stroke of the valve is not practical. At both the consulting engineer and end user levels, responsibility for process flow control and valve safety systems generally fall under the authority of Control Systems Engineering (Instrumentation) because the valves are automated. Often times this engineering discipline attempts to affect a Partial Stroke through the use of ancillary controls and instrumentation. This often results in making the SIS more complex, expensive, and subject to complicated software programming, installation, and commissioning. The following criteria should be considered when considering methodology for affecting the Partial Stroke Test of a SIS, including the associated ESD valve: Keep it a Simple System (KISS) Because a mechanical Partial Stroke Test Device does not require the addition of extensive extraneous controls, several important user benefits are realized. There are no requirements to add additional power, wiring or control systems to perform a partial stroke function test. The benefit is obviously 4 190697klc Figure 1: Typical example of a “sandwich-mount” product installed between the pneumatic actuator and valve. a reduction in capital cost and system complexity. Secondly, mechanical interlock systems are generally considered a more positive method of achieving the partial stroke. This option is discussed further in “Mechanical Characteristics”, below. Lastly, we can make these systems as complicated as we want to, but more times than not, it is important to keep things simple and safe. In the real world, often times the less complex the system, the fewer things will go wrong. Mechanical Characteristics Perhaps the primary advantage of the mechanical Partial Stroke Test Device is just that: It’s mechanical. A typical installation of a mechanical Partial Stroke Test Device would be to mount the device “sandwich” style between the valve bonnet (mounting flange) and the drive face (or bottom) of a pneumatic valve actuator. (See Figure 1). Within the device there is a drive mechanism that, once engaged, prevents the de-energized actuator from causing the valve to stroke more than a specified percentage of full travel—thus accomplishing the partial stroke. There is no mandatory device requirement to integrate it into the control loop or add ancillary controls. Therefore, there is no complexity added to what might already be a rather sophisticated control loop or shutdown system. Field Retrofits/No Calibration Although Partial Stroke Test Devices are often supplied with a new valve/actuator package, they are also field retrofitable to existing valves. As mentioned previously, typical installation of these products is to sandwich them between the valve and actuator. Mechanical partial stroke devices can be furnished with mounting surfaces premachined to fit an existing valve and actuator interface. This makes the installation of the device simple and cost effective. In fact, depending on the specific valve and actuator, in many VA LV E M A G A Z I N E 4 2/28/03, 8:33 AM instances the sandwich-style device can actually replace typical valve/actuator mounting hardware. Instrumentation personnel and software programmers are not required to install the devices, nor is commissioning or routine calibration of controls required, because there aren’t any. Most process plants have qualified in-house mechanics or Valve Automation Centers nearby and, since there are no additional controls required, installation cost savings can be realized when compared to electrical or controls-driven test systems. Real World Automation Figure 2: Fabricated body of a Partial Stroke Test Device. Valve Stem would be connected to the device through the bore and keyway. specified percentage or degree of valve closure and will not give spurious SIS trips (alarms) based on extraneous conditions. Further, when using non-mechanical or controls-driven partial stroke test systems there is an assumption that the test device or system will actually prevent the actuator from driving the valve past the set point to the fully closed position. In the real world, the stored energy in an actuator may drive the valve past the set point and actually allow the valve to close, forcing a process shut down. Mechanical devices physically prevent the valve from moving past the specified test point. Once the test device is engaged, the valve cannot move past the set point. (Figure 2 - Figure 4) Many process plants also use electric Motor Operated Valves (MOVs) in critical process applications. Although most MOVs have internal mechanisms that can be set to stop valve movement at a specified percentage of stroke, plant operators often select a mechanical Partial Stroke Test Device to prevent valve closure should the internal mechanism malfunction. Although the point behind partial stroke testing is to establish a statistical analysis for lowering the Probability of Failure on Demand, as one industry speaker recently put it: “Calculations are not necessarily reality!” Therefore, the process operators must take care to assure that real world conditions are considered when selecting a methodology for partial Figure 3: During normal operation, the stroke testing. device is passive and will allow the valve ESD valves are often large and are to ESD on demand. typically operated by pneumatic or hydraulic piston cylinder actuators, or electric motor operators. Due to the critical nature of the application, one Man-Machine Interface? would expect the ESD valve to seldom operate. Although piston cylinder Partial Stroke Testing is receiving actuators are considered extremely increased attention as the aforemenreliable, in the real world these devices tioned industrial standards are considare not always smooth-acting. The less ered by industry. Progressive refineries, often they are stroked (as in the case of a process plants, pipeline companies, etc., typical ESD valve application), the less are going through an evolutionary smooth is their operation. This might be Figure 4: When a partial stroke test is process of developing the methodology caused by the elastomeric piston o-rings by which they will comply with the required, the device is “engaged” and the taking a set against the interior surface of ESD valve will only travel to the specified standards and how those methodologies percentage of stroke. The device the cylinder. will be implemented. One of the mechanically prevents movement past the Most of the non-mechanical Partial considerations is, to what extent should interlock. Stroke Test Devices assume a relatively plant personnel be proactively involved smooth movement of the valve actuator in performing the test of process valve and that the SIS will act in a consistent manner, indepenSafety Instrumented Systems? dent of environmental conditions such as temperature and One philosophy of methodology calls for a Man-Machine humidity or how long the valve rests between test cycles. interface. In the simplest format, mechanical Partial Stroke Test This is rarely the case. The primary function of a mechanical Devices provide for a plant maintenance person to locally Partial Stroke Test Device is to stop valve movement at a engage the device using a controlled key (See Figure 5). FALL 2002 190697klc 5 2/28/03, 8:33 AM 5 that the actuator will not stroke the valve By design, the key cannot be removed past the set point. from the mechanical testing device while A mechanical sandwich-type Partial it is in the test position. If plant operaStroke Test Device may also come tions personnel know the key is in their equipped with its own data point device control and not in the test device, then (such as limit switches) for positive they also know the device cannot be annunciation to the control room engaged. When it is time to test the indicating whether the device is engaged valve, the maintenance person inserts the for testing the Safety System. Some may controlled key into the device, engages want to use such a device to gather the device and then informs the control information for the data acquisition room that the valve is now ready to test. system such that auditable reports, When the SIS test is simulated, the Figure 5: For manual operation, a testifying to time and date of the test, can person witnesses and reports the event, controlled key is used to engage the be generated (Reference ISA-S84.01, usually by radio, to the control room, and Partial Stroke Test Device. The key cannot be removed from the mechanical paragraph 9.8.1). then resets the system. Plant operations, testing device while it is in the test Controls can also be configured to safety engineers and management are position. If plant operating personnel automatically disengage a Partial Stroke assured the of the system’s reliability know the key is in their control and not Test Device in the unlikely event of an because “the man saw it function”. in the test device, then they also know ESD occurring during the test. (Figure 6, Figure 7a, and Figure 7b) the device cannot be accidentally engaged. Management philosophies at other plants may hold a different view: They True Safety System Tests want the entire system to be automatic As previously stated, a mechanical with absolutely no human interface. Many mechanical Partial Partial Stroke Test Device requires no extraneous controls or Stroke Test Devices provide for automatic operation as an devices to be added in the safety control loop. When the option to the Man-Machine interface. Under this methodoldevice is tested, all the actual SIS components, controls and ogy, a remotely controlled mechanism is used to engage and elements used in an ESD or safety valve will be activated. disengage the device and there is no key control system. The The user has real information about the exact controls that ESD valve can then be tested either by a signal generated by will be relied upon to protect his plant and personnel. the control room or any number of other sources without field personnel involvement. Valverciser™ Mechanical Partial Stroke Test Devices offer plant operaAn additional feature of mechanical Partial Stroke Test tions and maintenance management both manual or autoDevices is that they are not only applicable to safety related matic operating options as their philosophies dictate. In either applications, but can also be used to enhance the operation of case, diagnostic devices can be integrated into the system to the valve. In many process applications the chemical report specific operating details of the SIS function. composition of the flowing fluid causes material to build-up on the valve internal body and trim surfaces. Over time, this Integrated Data Systems build-up may cause the valve to “stick” in position and not Some end users are beginning to investigate diagnostic stroke. Partial Stroke Test Devices can be used to simply technology for valve maintenance considerations. The data “exercise” the valve by allowing it to partially stroke, keeping acquired from these systems may be helpful in determining the the valve surfaces that are required to move free from material operational status of an automated valve. Even though build-up. mechanical Partial Stroke Test Devices do not require ancilMany mechanical Partial Stroke Test Devices can also be lary controls, such controls may be added if the end user configured to accommodate maintenance lock-in, tag-out specifies them (Figure 8). For example, if the user would like requirements as well. to have a data acquisition system to determine if the valve/ actuator package is experiencing a change in run time trends, All Things Considered... the actuator top works can use standard diagnostic technology Now that we have fully explored the benefits of mechanical to report that information. But because the mechanical Partial Stroke Test Devices it should be clear that the simplicdevice is engaged during the test, the end user has assurance ity, safety, reliability, and cost advantages of the devices far 6 190697klc VA LV E M A G A Z I N E 6 2/28/03, 8:33 AM Figure 6: During normal operation, key is kept in a controlled environment and device is free to operate and is transparent to the ESD valve operation. Figure 7a: When it is time to test the ESD, maintenance inserts the controlled key into the device... Figure 8: Although mechanical Partial Stroke Test Devices do not require ancillary controls, they may be added if specified. outweigh the whiz-bang factor of adding more controls and instrumentation to what is probably already a sophisticated valve safety system. Consideration and use of the mechanical devices will lead to “sunny days ahead” when battling the oncoming storm of standards compliance! VM The author is Vice President, Sales, DynaTorque Inc., Muskegon, MI; 231.739.1431; www.dynatorque.com; mmitchell@dynatorque.com. © Fall 2002 Valve Magazine and Valve Manufacturers Association of America (VMA), Washington, DC. All trademarks, trade names, service marks and logos reference herein belong to their respective companies and the VMA. Valve magazine articles or content may not be reprinted or reproduce in any format without written permission from the VMA. For more information, please visit www.vma.org. Figure 7b: ...the device is then “engaged” and maintenance informs the control room that the ESD is now ready to test. FALL 2002 190697klc 7 2/28/03, 8:33 AM 7 Critical Valve Test? D-STOP™ it! Plants need to make sure ESD and other critical safety valves function properly now that maintenance shutdowns for “full-stroke testing” are less frequent. The DynaTorque D-Stop™ (Patent Pending) allows safety control elements to be tested, but does not allow the valve to fully-close during the test so the “revenue flow” is not affected. Partial Stroke Testing may lower the Probability of Failure on Demand (PFD) or may increase the time interval required between full-stroke tests. The D-Stop™ covers actuator torque ranges from 3000 lbin to 4,000,000 lb-in. It is a reliable mechanical device. Diagnostics and ancillary controls can be added, but they are not required. No software or commissioning, so capital costs are low. Most important? The D-Stop™ keeps the system simple and safe. In the real world, the less complex the system, the fewer things can go wrong! For remote and/or automated applications the key and safety release are not required. The top actuator controls the valve, while the smaller actuator on left engages/disengages the D-Stop™. Limit Switches (left and bottom) may be added to provide feedback to I/O system indicating the D-Stop™ has been engaged and that the device is in the test position. Data points can be fed to a data acquisition system for the Partial Stroke Test audit trail. 8 VA LV E M A G A Z I N E Ph. 231-739-1431 190697klc Fax. 231-739-4514 8 www.dynatorque.com/dstop 2/28/03, 8:33 AM info@dynatorque.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Create Date : 2003:02:25 14:26:03Z Modify Date : 2003:03:20 09:12:00-06:00 Page Count : 8 Has XFA : No Creation Date : 2003:02:25 14:26:03Z Producer : Acrobat Distiller 4.05 for Macintosh Mod Date : 2003:03:19 13:29:09-06:00 Metadata Date : 2003:03:19 13:29:09-06:00EXIF Metadata provided by EXIF.tools